LIST OF MAIN ELECTRICAL EQUIPMENTS OF HOUAY LAMPHAN HPP

No Names equipment- item Powerhouse and switchyard station Generator G1, G2,G3 (attach excitation system) Specification Unit Quantity

3 phases synchronization, vertical axis P =5,0MW, U = 6,3kV, f = 50Hz, Cos =0,8, n = 300rpm 2 windings, 3 phases, oil cooling, outdoor, no load controller Sdm =6,3MVA, Uk =10,5% 6,3/121 2x2,5%kV 3 phases, 2 windings, dry type, indoor S=250kVA 6,3 2x2,5%/0,4kV 250Ah, 220VDC 25KVA, 380VAC To install in the Lower Houay Lamphan hydropower project

set

Main transformer T1, T2.

unit

3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29

Auxiliary transformer TD1, TD2 Generator terminal distribution cubicle (include generator neutral cubicle) Input cubicle from 400V auxiliary transformer and Diesel generator Generator-transformer control and protection cubicle 115kV line protection and automatic cubicle Central signal cubicle Programming cubicle Synchronization cubicle Fire fighting cubicle AC auxiliary power distribution cubicle DC auxiliary power distribution cubicle Lighting supply cubicle Temperature inspection cubicle Hydraulic quantities measurement cubicle Unit excitation transformer cubicle Unit excitation cubicle AVR cubicle Unit local control cubicle Unit signal, monitoring, measurement cubicle Battery cubicle Battery charge cubicle Powerhouse control computer system Whole powerhouse telecommunication system (optical information system, telephone central office, paging system) Whole powerhouse measurement system Whole powerhouse lighting system Whole powerhouse fire fighting system Strength cable, control cable

unit Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle Cubicle System System System System System System

2 10 3 2 1 1 1 1 2 4 2 2 1 1 2 2 2 2 2 2 2 1 1 1 1 1 1

30 31 32 33 34 35 36 37 38

systems Switchyard and powerhouse earth, lightning system Circuit breaker and auxiliaries Disconnector and auxiliaries Current transformer and auxiliaries Current transformer and auxiliaries Accumulate type voltage transformer and auxiliaries Valve arrester and auxiliaries Busbar,electric porcelain, conduction wire, lighting, lightning, diamond-shaped lattice truss structure, and auxiliaries of outdoor switchyard station Diesel generator

System 123kV, SF6, 630A, 20KA 3 terminal type, 123kV, 630A 123kV, 40/1/1/1/1A 123KV, 50 100/1/1/1/1A 115: 3 /0,1: 3 /0,1: 3 KV 96 KV 115KV 100KW set set unit unit set set System set

1 3 4 6 3 2 3 1

LIST OF MAIN ELECTRICAL EQUIPMENTS OF HOUAY KAPHEU HPP


No I 1 2 3 II 1 2 3 4 Name of equipments Transformers Main transformer: 3 phases, 2 coils, oil-immersed, out-door and ONAN-type cooled. Self-consumed transformer 1: 3 phases, 2 coils, in-door and AN-type cooled. Self-consumed transformer 2: 3 phases, 2 coils, oil-immersed, out-door and ONAN-type cooled. Synchronous distribution equipment at voltage supply for generator 6.3KV Transformer cabinet Cabinet containing excitation transformer for electric generator. Transformer cabinet and lighting arrester of step-up transformers input valve Input cabinet for the self-consumed transformer: 2 sub-switches, one grounded side and one protection fuse unit. Cabinet for isolating switch and generator terminals current transformer One-way and alternating selfconsumed electric supplying system Input cabinet at low-side of selfconsumed transformer 1 & 2 Alternating self-consumed electric distribution cabinet Uninterrupted alternating electric distribution cabinet (UPS) System of battery Battery charging cabinet One-way electric distribution and input cabinet Main lighting cabinet NM (normal situation and emergency) Fire extinguishing & precaution cabinet Automatic, protecting, measuring & controlling electric-equipments Computer system for generally controlling and monitoring whole powerhouse Cabinet for controlling protecting generators transformers Cabinet for protecting voltage line 22KV Central signal cabinet Synchronous cabinet Information cabinet Abinet for gauging hydraulic quantities Technical parameters Srated=3200KVA; Yo / -11 24 2x2,5% / 6,3KV Srated=160KVA 6,3 2x2,5% / 0,4KV Srated=160KVA 24 2x2,5% / 0,4KV Unit Quantity

Unit Unit Unit

2 1 1

6,3 0,1 0,1 / / KV 3 3 3


Be synchronous with generator

Unit Unit Unit Unit

2 2 2 1

6,3 0,1 0,1 / / KV ; ZnO; 6,3KV 3 3 3


6,3KV; 100 A - Fuse 15A. - Grounding switch 6,3KV 6,3KV; 630A 300/1/1/1/1 A

5 III 1 2 3 4 5 6 8 9 IV 1 2 3 4 5 6 7

Unit

200A; 0,4 / 0,23KV 100A; 0,4 / 0,23KV 230V; 3KVA 220V,160Ah 220VDC 220VDC 0,4 / 0,23 KV

Unit Unit Unit Syste m Unit Unit Unit Unit

1 3 1 1 1 3 2 2

Syste m Cabine t Cabine t Cabine t Cabine t Cabine t Cabine

1 2 1 1 1 1 1

8 9 10 11 12 13 14 V

Temperature checking cabinet Central control panel Local control cabinet of machine unit Excitation cabinet for generator Automatic voltage control cabinet of generator Local self-consumed cabinet of machine unit Neutral cabinet of generator Including digital-electronic exchange with capacity of 24 numbers, telephones, fax machines, source and distribution connection equipments Including fire detector, fire bell, press-button and exit light Types of cable XLPE / PVC / Cu Including types of light, socket, wiring and switchgear 24KV; 630A; 20KA 24KV; 630A 24KV; 630A 24KV; ZnO khng khe h

t Cabine t Panel Cabine t Cabine t Cabine t Cabine t Cabine t Syste m

1 1 2 2 2 2 2 1

Contact information system inside and outside the powerhouse

VI Fire alarm precaution system VII VIII IX 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 System of load bearing cable and control cable Low power supply and lighting system Out-door distribution station Three-phase circuit-breaker Isolating switch with 3 phases and one grounded side Isolating switch with 3 phases and 2 grounded sides Lighting arrester for valve Three-phase voltage transformer Current transformer Current transformer My bin dng in Free-falling fuse String chain curtain with 3 octahedrals Post-type insulator Conductor Installed fitting Bus bar pole Feeder pole of conductor line Pole foundation Bearing pier for switch and current transformer Bearing pier for solating switch Bearing pier for voltage transformer Bearing pier for valves lighting arrester Bearing pier for switch and current transformer Foundation of bearing pier for isolating switch, valves lighting arrester, voltage transformer Self-consumed transformers foundation Main transformers foundation Main cable channel from the

Syste m Batch Syste m Set Set Set Set Set Set Set Set series Unit m Batch pole pole founda tion Unit Unit Unit Unit Found ation Found ation Found ation Found ation m

1 1 1

3 2 2 3 2 2 1 1 9 3 250 1 5 2 7 3 4 1 3 3 8 1 2 30

24 0,1 0,1 / / KV 24KV; 3 3 3


24KV; 100/1/1/1/1A 24KV; 200/1/1/1/1A 24KV; 5A C-70 or equivalence 24KV ACSR 150/19 LT-8B LT-12B

B=800mm

25 26 27 28 X XI XII

powerhouse to electric distribution station 22KV and in the distribution station Branch cable channel in the transformer station Distribution stations gate Distribution stations guard fence Motor road at the distribution station Lightning protection and grounding system Connection electric 22kV Line 22kV compensating for inundated segment in reservoir bed

B=600mm

m Set m2 m2 Syste m Km Km

50 1 155 52 1 3,2 1

B=4m Detail design will exist then Detail design will exist then. Construction cost is calculated in land clearance compensate cost