laser & light technology

Analytical
Report
Apogee Elite
Over the next several months I will be CYNOSURE INC.
investigating new light-based aesthetic
devices from a variety of manufacturers,
on-site at their facilities. These reviews
will examine both the strengths and weak-
nesses of these new products from a purely By David M. Cauger, Contributing Editor
objective position.
I will be using testing meters and asking
hard questions about these devices. I will
report my findings, both positive and
negative, in a language that is hopefully ynosure, Inc. revealed the Apogee impressive 80 J/cm2 with a 10mm
straightforward and easy to understand. Elite at the Annual Meeting of spot with the its 1064nm Nd:YAG.
All manufacturers that agree to these American Academy of Dermatology The Elite has spot sizes of 3, 5, 7, 10,
reviews will be informed in advance of the
in Washington, D.C., in March of this 12 and 15mm, pulse durations
methods and approach. The goal of these
reviews is to provide the physician an year. On June 10th I visited between 0.4ms to 300ms, and repeti-
unbiased look at new light-based devices Cynosure at their headquarters in tion rates of up to 5 shots per second.
and what they may or may not offer in Chelmsford, MA, to examine the These specifications provide incredi-
terms of expanded treatment options and dual wavelength laser. The Elite is a ble versatility.
improved treatment outcomes.
high-powered variable pulse 1064nm For example, it will allow a hair
I have no financial interest nor do I Nd:YAG, and proven variable pulse removal treatment of a skin type II
receive any compensation from the com-
755nm Alexandrite in one single patient with a 755nm mode; and in
panies reviewed in this series of articles
or Aesthetic Trends & Technologies. These unit. This is, without question, the less than 30 seconds, it can be treat-
reviews do not necessarily reflect the best designed marriage of two long ing reticular leg veins with a 1064nm
opinion of Aesthetic Trends & Technologies. pulse mode. This is but one scenario which
ATnT is in no way responsible for the out-
wavelengths in the emerging trend distinguishes the Elite as a first
come of any individual or entity, whether
positive or negative, if they choose to of multi-wavelength aesthetic lasers. choice laser for those offices that do
purchase one of the products reviewed in While several companies do offer not currently own a high-powered
these reports. The objective of this series a 1064/755nm laser, they are lacking Nd:YAG or an Alexandrite.
is to report on products currently offered in the required fluences on the There has never been, nor will
in the aesthetic medical community and
1064nm side as well as other critical there ever be, a single wavelength
to provide an avenue of understanding
for those who have an interest in these specifications. The Elite does not which can treat the same cosmetic
devices for their practice. share these problems and delivers an conditions on all skin types. If I could

summer 2004 | www.aesthetictrends.com 23


__
view this as a downside. However,
FDA-Cleared Treatments,
Apogee Elite this approach allows for lighter
handpieces as well as assurance that
755 nm 1064 nm if a lens on one handpiece requires
Alexandrite ND:YAG
replace-ment, which is common to
Hair Removal, Hair Removal, all lasers, one can simply substitute
Lighter Skin Types Darker Skin Types another size, thus keeping the laser
in operation. Changing spots sizes is
Pigmented Lesions Telangectasias and
very simple and easy. I did it
Cherry Angiomas
successfully on my very first try.
Leg Veins Simply remove the handpiece from
the end of the cable, snap on a new
Non-Ablative one and place it in the calibration
Wrinkle Reduction port in the top of the machine.
The Elite automatically senses
pick only two wavelengths for a cos- the spot size, and you are ready to
metic practice, it would be a 755nm select parameters and treat. If you
Alexandrite and a variable pulse are switching between 755nm and
high powered 1064nm Nd:YAG. Apogee Elite by Cynosure, Inc. 1064 modes, the Elite will remember
Having both of these wavelengths in your previous settings or you have
one single unit with the Elite’s supe- Both the laser and the facilities the option to override. The hand-
rior power specifications sets a new were well designed and orderly. The piece connects to a SmartCool™
standard for all aesthetic laser Cynosure staff allowed me to test the (Cryro 5 Zimmer) chiller. This is an
companies. controls, and I was given complete elegant and quiet stand-alone refrig-
I spent five hours reviewing the instruction in the use and operation eration unit which will bring surface
clinical uses and design with Marina of the laser. After this session, three skin temperature down near freezing
Kamenakis, V.P. of Marketing; Evan solar lentigos of approximately 3mm in about 30 seconds.
Sherr, Director, Clinical Research; in diameter on my upper back were The SmartCool provides a good
successfully epidermal cooling strategy and can
treated. also be incorporated into many other
treatments not related to those of the
The Elite has a straightforward touchpad interface
ELITE OPERATION Elite. Examples of this would be
with a monochrome LCD display. chemical peels or Erbium YAG
The Elite can
be ready in resurfacing. The Elite has a straight-
Nd:YAG mode forward touchpad interface with a
Rafael Sierra, Ph.D., Chief Technical within 7 seconds of turning it on. The monochrome LCD display.
Officer; and James Boll, Director, Alexandrite crystal takes only about
New Product Development. All the ten minutes to be ready for Elite handpiece
above personnel were very candid operation. After this point one can
and did not hesitate to answer some switch seamlessly between both
of the tougher questions I had pre- wavelengths without having to
pared. I was allowed a full internal reboot the laser. Handpieces are
inspection of the laser as well as the very light and ergonomic.
production facilities for all of The spot sizes cannot be “dialed
Cynosure’s products. in” to various sizes, and some may

24
__ summer 2004 | www.aesthetictrends.com
Elite. These specifications are
APOGEE ELITE SPECIFICATIONS formatted almost exactly as they
appear on the back of the brochure.
All manufacturers should provide
specifications in this format.

ELITE HAIR REMOVAL: 755NM


ALEXANDRITE & 1064NM ND:YAG
Experienced practitioners who
own both a high-powered 1064nm
Nd:YAG and a good 755nm
Alexandrite will report very similar
approaches to hair removal. For
Fitzpatrick types I-III that are not
tanned, they always choose the
755nm Alexandrite. If the patient is a
Fitzpatrick type IV-VI, they almost
always first choose the 1064 Nd:YAG.
The only variance of choice is with
type IV where, depending upon the
anatomical area, some choose to pre-
treat with tyrosinase inhibitors and
then treat with Alexandrite. The rea-
son for this is that the 755nm has a
higher coefficient to the target
chromophore melanin than does the
ELITE SPECIFICATIONS maximum fluences at the available Nd:YAG.
I am very pleased to see that spot sizes at a given pulse duration, If the Alexandrite is of good
Cynosure provides transparency in and also the speed a laser can quality, in good working condition
their product specifications. For once deliver in 1 second. This is its repeti- and appropriate parameters are
I did not have to re-construct or tion rate. Finally, available pulse used, it will in almost all cases
calculate maximum fluences because durations and epidermal cooling. produce a significantly higher rate of
they are stated clearly on the back of It is important to note that follicular destruction than even a
the brochure. aesthetic lasers rarely need to have high- powered Nd:YAG. This is even
When purchasing a laser, first pulse widths greater than 65 milli-
decide what you wish to treat, know seconds so don’t bother to consider
the predominant skin types of your anything beyond that as a benefit. If Photos courtesy of Brooke A. Jackson, M.D
patient base, and check the repu- any company’s specification states
tation of the company. After that, “up to” 300 J/cm2, ask them with
buy on specifications. what spot size and pulse duration do
Specifications ultimately will they achieve that fluence. It is best to
determine treatment outcomes. Do ask them the maximum fluences with
not waste your time reading each spot size and whether or not it
sponsored clinical studies or is independent of pulse duration.
Before (left) and After (right)
physician testimonials. Buy on speci- The chart above shows basic but
9 months post 7 treatments with the Elite
fications. The key specifications are critical specifications of the Apogee

summer 2004 | www.aesthetictrends.com 25


__
w w w . a e s t h e t i c t r e n d s . c o m

ABSORPTION COEFFICIENT SUGGESTED PARAMETERS, HAIR REMOVAL

10 4 Pulsed 755 nm Alexandrite


Dye 1064 nm ND:YAG
(585,595) Alexandrite
(755)
Skin Type 10 mm J/cm2 Pulse Duration 10 mm J/cm2 Pulse Duration
10 3 Diode
(810)
Nd:YAG
(1064)
I & II 20 – 35 5 – 20 ms N/A N/A
10 2
III 18 – 30 10 – 20 ms N/A N/A
Melanin
IV 15 – 25 30 – 40 ms 40 – 60 20 – 40 ms
10 1
Oxyhemoglobin V N/A N/A 30 – 55 30 – 40 ms
VI N/A N/A 25 – 45 40 ms
0.1 Skin Type 12 mm J/cm2 Pulse Duration 12 mm J/cm2 Pulse Duration
400 500 600 700 800 900 1000 1100
Wavelength (nm) I & II 20 – 35 5 – 20 ms N/A N/A
III 18 – 30 10 – 20 ms N/A N/A
IV 15 – 25 30 – 40 ms 35 – 50 30 – 40 ms
truer with hair which has less mass V N/A N/A 30 – 50 40 ms
or is light brown. Furthermore, hairs VI N/A N/A 25 – 45 40 ms
often become miniaturized after sev-
Skin Type 15 mm J/cm2 Pulse Duration 15 mm J/cm2 Pulse Duration
eral treatments and therefore
present less of a target. Very simply, I & II 20 – 35 5 – 20 ms N/A N/A
an Nd:YAG requires a greater target III 18 – 30 10 – 20 ms N/A N/A
than does the Alexandrite. The IV 15 – 25 30 – 40 ms 30 – 40 30 – 40 ms
Nd:YAG also has an affinity for the V N/A N/A 25 – 35 40 ms
chromophores of both oxyhemo- VI N/A N/A 20 – 35 40 ms
globin and water.
While this characteristic gives
NOTE: The variances in fluences, pulse durations and spot sizes are determined by individual examination, test spots, and
the 1064nm Nd:YAG its great versa-
the anatomical region to be treated. It is always best to use the highest fluences which are safe and tolerable to the patient.
tility, it also means it requires higher Larger spot sizes are preferable when large areas need to be treated and hair is of larger diameter and deeper seated.
fluences to overcome the competing
chromophores and its relatively
weak attraction to melanin. Asian skin would be but one If miniaturization occurs, it would
On the other hand, the downside example of how the tandem use of be wise to shorten the pulse duration.
of any Alexandrite is the risk of the Elite’s 755/ 1064nm wavelengths If treating anatomical locations where
adverse reactions when treating skin could be creatively used. In lighter hairs are deeper seated such as the
types IV-VI or tanned patients. Asians skin types the practitioner pubic region, it is wise to use the
Fluences have to be lowered to avoid may test the patient with 755nm at 15mm spot with slightly longer pulse
risks of hyperpigmentation, hypopig- 15 J/cm2 @ 40ms with a 12 mm spot. durations. These rules are set forth in
mentation and burns. These lower If perifollicular edema is achieved Cynosure’s clinical guidelines, and
fluences may result in delayed re- and no pigment changes occur in the the 10mm spot should be used only in
growth, but the odds in permanent skin, then it is common to increase areas where it is not practical to use
follicular death drop dramatically in the fluences by 1 Joule inntervals. the 12mm spot.
proportion to these lowered fluences. If no unwanted side effects are However when treating darker
The Absorption Coefficient chart, observed, then that is the fluence Asian types, typically classified as a
above, will provide a visual refer- which should be used for that skin types 4 or 5, it is best to start
ence of these realities. anatomical location. with the Nd:YAG, performing a test

26
__ summer 2004 | www.aesthetictrends.com
spot at 40 J/cm2 @ 20ms with a 10mm ELITE VASCULAR TREATMENTS:
spot. If no side effect is observed, 1064NM ND:YAG
move up in fluence in increments of 5 The specifications of the Apogee
J/cm2 to a maximum of 60 J/cm2. Elite will allow it to successfully
After the 3rd treatment you may treat telangiectasias of the face and
notice that the hairs have less diame- legs, cherry angiomas, and leg veins
ter but are still a cosmetic concern to up to 2.0mm in diameter.
the patient. In this case it may be With vessels over 2.0mm it is my
wise to prescribe a tyrosinase firm conviction that sclerotherapy be
Before (left) and After (right)
inhibitor such a hydroquinone to the first treat-ment modality
130 J/cm2, 20ms, 3mm spot
lighten the skin as well as a followed by the Nd:YAG to remove
sunblock. any matting which may occur post
When it is observed that the treatment. With telangiectasias it is best to
patient has complied with the Leg veins over 1mm are start at the end of the vessel and
prescriptions, you may now employ challenging to treat. Be sure to work toward the feeder using a 10%
the 755nm Alexandrite for 2-5 more receive thorough training before overlap with each pulse.
sessions starting with 18 J/cm2 to offering this service. Appropriate topical anesthesia
finish off these miniaturized hairs. When treating vessels it is may be required. The table on the
This strategy works fine for areas recommended that a coating of cold left contains suggested treatment
which are not large such as men’s ultrasonic gel or substantial parameters using the Elite’s 1064
backs where applications of the equivalent be used in conjunction wavelength.
prescriptions are not practical. In with the SmartCool system designed
those cases where tyrosinase to provide epidermal cooling during ELITE PIGMENTED LESIONS
inhibitors cannot be used in order to treatment. TREATMENTS: 755NM ALEXANDRITE
safely use the 755nm wavelength, it The Apogee Elite uses short
is best to shorten up the pulse dur- SUGGESTED PARAMETERS, pulse durations with a 5mm spot to
ations of the Nd:YAG in proportion to VASCULAR TREATMENTS remove simple and solar lentigos.
hair diameter. During my visit to Cynosure’s offices
Pulse
It is best to advise patients that Spot Pulse Rate I had four solar lentigos on my upper
up to 6–8 treatments may be required Area Size Duration J/cm2 (sec.) back treated. I am pleased to report
to achieve an acceptable result. In Facial that three are now completely absent
3 mm 10 – 20 ms 125 – 140 1 – 1.5
any event, the strategy of using the Telangiectasias and one would require another treat-
alexandrite and high-powered Facial ment at a higher fluence. No adverse
Telangiectasias 3 mm 10 ms 110 – 150 1–2
Nd:YAG in tandem for hair removal < 0.5 mm
reactions occurred. The table on the
is something advanced practitioners next page contains suggested
Spider Veins
have been doing successfully for sev- Superficial 3 mm 20 ms 110 – 180 1–2 parameters for Fitzpatrick types I–III.
eral years. Having both of these > 0.5 mm – 1 mm

options in one device allows the most Spider Veins ELITE NON ABLATIVE TREATMENTS:
Reticular 5 mm 20 – 40 ms 120 – 180 1–2
comprehensive approach to hair 1 mm – 2.0 mm
1064NM ND:YAG
removal and subsequent patient sat- The non-ablative skin rejuvena-
Leg Veins
isfaction. 7 mm 40 – 60 ms 150 – 170 1–2 tion treatment of the Apogee Elite
1 mm – 2.0 mm
The chart on the previous page will generate new collagen synthesis
contains my basic suggested param- NOTE: The variances in fluences, pulse durations and spot sizes are determined in select patients and improve the
by individual examination, test spots, and type of vessel. The above settings are
eters for hair removal with Apogee for Fitzpatrick types I-III. Use cold packs immediately after treatment followed by appearance of some rosacea sub-
an antibiotic ointment or occlusive to prevent dryness and crusting. Avoid sun
Elite. exposure and exercise for 1 week following treatment of leg veins. types and superficial telangiectasias.

summer 2004 | www.aesthetictrends.com 27


__
The objective in achieving collagen rhytides also respond better so it is a CONCLUDING COMMENTS
synthesis is to heat the upper treatment which lends itself to the This is my third analytical
papillary dermis by absorption of conjunctive use of BOTOX™ and product review, and some of the
laser energy by water and diffusion dermal fillers. faithful ATnT readers are perhaps
of heat from the microvasculature to wondering why each device has
a temperature between 45°C and SUGGESTED PARAMETERS, received high marks. The reason is
50°C. NON-ABLATIVE TREATMENTS that all of my assignments have been
The face is treated in sections of with the very latest product offerings
approximately 20-25 square centime- Spot Pulse Shots per
from the top tier companies. It goes
Area Size Duration Fluence Sec. (Hz)
ters. The tip of the 5mm spot is held without saying that I will not be
about 1-2 centimeters from the skin Face 5 mm 0.4 ms 13 – 18 J/cm2 5 reviewing sub-par devices in the
surface. This will defocus the beam near future, and there are many sub-
to about 8mm. Move the handpiece par devices on the market.
across the area in a relatively fast PRICE, KEY FEATURES, AND There are many products I
motion back and forth over the treat- WARRANTIES wouldn’t buy as paperweights and
ment area in a left to right and top to System Price. The list price of some which obviously are superior to
bottom. Once the first pass is the Apogee Elite is $115,000. This others. I can say with the fullest con-
complete, repeat the same pattern at includes 6 spot sizes and a fidence and without reservation that
the original starting location and SmartCool™ for epidermal cooling. the Apogee Elite is a superior laser.
then move to the next area. In This is a hefty price tag but for If you do not already own a good
general, patients in their 30’s to early the office which does not own a high- Alexandrite or one of the few high-
50’s with mild rhytides respond best powered Nd:YAG or an Alexandrite, powered Nd:YAG’s on the market,
to this treatment. Non-dynamic it is a bargain. You also save by pay- this is the best option currently
ing only one available. The tandem use of these
warranty and wave-lengths is well established,
have to deal and you will invariably find them
The ability to switch wavelengths with these fluences
with only one employed in most experienced
is a major breakthrough and can allow several company for cosmetic practices.
different treatments in one session. service. In addi- Cynosure has quite a number of
tion, the excellent products, having been a
SmartCool™ top tier company for many years.
may be used for other purposes. However, the Elite is clearly its most
SUGGESTED PARAMETERS, Spot Sizes. 3, 5, 7, 10, 12 & advanced product to date. In
PIGMENTED LESIONS 15mm. Changing spot sizes is fast addition, for its outstanding
and easy. The ability to switch wave- specifications with both its 755nm
Skin Type Spot Size Pulse Duration Fluence lengths with these fluences is a major and 1064nm wavelengths, the
break-through and can allow several Apogee Elite currently stands
I & II 5mm 0.5 ms 20 – 30 J/cm2
different treatments in one session. without an equal in the aesthetic
III 5mm 0.5 ms 18 – 25 J/cm2
Warranties. The Elite carries a laser industry.
full 1 year warranty: After 1 year the
NOTE: It is important that a qualified physician examine all lesions prior to service plan is $6,900 annually. David M. Cauger is President of Boston
treatment. Grey or white appearance post treatment indicates too high fluence.
Aesthetics, LLC, specializing in the devel-
Darkening of the lesion is the preferred end-point in most cases. It is best to test Consumable Cost. None, except opment and implementation of strategies
treat two to three lesions on a non-obvious location before commencing treat-
ments in obvious locations. Epidermal cooling is not recommended. For occular the usual lens or fiber from time to for increased cosmetic practice success.
regions, eye shields are recommended. Patients should apply the newer titanium Contact Mr. Cauger at: 978.562.5015, or for
dioxide/zinc oxide sunblocks to treated areas whichwill be exposed to sun.
time. light based device questions free of charge
send an email to: cauger1@gis.net.