rpf
RAPT - Version: 6.3.2.0
Reinforced And Post-Tensioned Concrete Analysis & Design Package
Copyright(C) 1988 - 2011 PCDC Pty. Ltd. All Rights Reserved
Licensee
Alliance Design Group Pty Ltd
3/22 Marine Parade
Southport QLD, 4215
10155062180610WPN4
Input
General
List
Design Code
Australia - AS3600-2009*SAVED*
List Australia - Australian Materials - 2009*SAVED*
Material
List
Reinforcement Type
Reinforced
List
Member Type
Slab
List
Panel Type
Internal
List
Strip Type
Two way
List
Column Stiffness
Equivalent Column
List
Concrete - Spanning Members
65MPa
List
Concrete - Columns
40MPa
mm
Top Reinforcement Cover
46
mm
Bottom Reinforcement Cover
41
mm
Top Reinforcement Axis Depth Limit
20
Bottom Reinforcement Axis Depth Limit mm
20
kn/m3
Concrete Unit Weight
25
List
Self Weight Definition
Program Calculated
Y/N
Pattern Live Load
Y
List
Earthquake Design
None
%
Moment Redistribution
0
List
Design Surface Levels
Extreme Surfaces
Span
Span Span Slab Panel
Length Depth Width
Left
mm
mm
mm
LE
250
1
13333 470 13333
2
13333 470 13333
3
13333 470 13333
RE
250
Panel Column
Column
Width Strip Width Strip Width
Right
Left
Right
mm
mm
mm
13333
13333
13333
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Columns
Column Column Support Column Column Column Column Column Column Transverse Capital Depth Pin Percentage Braced Column
Grid
Type Height Width Length Height Width Length Column
below
Base Column frame Shortening
Reference
Above Above Above below below below spacing
deepest below Stiffness at this Restrained
section
column
A
List
mm
mm
mm
mm
mm
mm
mm
mm
Y/N
%
Y/N
Y/N
1
1 Column 3500
500
500 3500
500
500
13333
0
N
50
Y
N
2
2 Column 3500
500
500 3500
500
500
13333
0
N
50
Y
N
3
3 Column 3500
500
500 3500
500
500
13333
0
N
50
Y
N
4
4 Column 3500
500
500 3500
500
500
13333
0
N
50
Y
N
Column Punching Transverse Transverse
Shear
effective prestress
Check
depth
(P/A)
required difference
Y/N
mm
MPa
1
Y
0
0
2
Y
0
0
3
Y
0
0
4
Y
0
0
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:24 AM
Load Cases
Load Load Type Load Definition Live Load Description
Case
Deflection
Case
List
List
Y/N
A
1
Self Weight Applied Loads
2
Live Load Applied Loads
Y
Description
1. Self 2. Live
Weight Load
A
#.#
#.#
Short Term - Deflection
1
0.7
Permanent - Deflection
1
0.4
Initial - Deflection
1
0
Page 2/26
License No.: 10155062180610WPN4
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:25 AM
Page 3/26
License No.: 10155062180610WPN4
Lateral Distribution
Spans Column Column strip % Column % Column
strip % at at maximum strip % at Strip moment
left end
midspan
right end to parallel
of span
moment
of span
beam
%
%
%
%
1
100
60
75
0
2
75
60
75
0
3
75
60
75
0
P1
13333
26666
13333
39999mm
P1
26666
39999mm
Reinforcement
Reinforcement Reinforcement Preferred Number
Use
Type
Bar Size of Legs
List
List
#
Flexural Bar
N 500MPa
Flexural Mesh
F 450MPa
Shear Option 1
N 500MPa
10
2
Shear Option 2
N 500MPa
12
2
Shear Option 3
N 500MPa
16
2
Punching Shear
N 500MPa
10
2
Reinforcement
Maximum Minimum Minimum Minimum Span Minimum Span Infill Stagger
Bar
Bar
Continuous Reinforcement Reinforcement Bars Bars
Spacing Spacing Reinforcement
into End
into Internal
Support
Support
mm
mm
#.#
#.#
#.#
Y/N Y/N
Support Reinforcement
300
99
0
N
N
Span Reinforcement
300
99
0
0
N
N
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:26 AM
Page 4/26
License No.: 10155062180610WPN4
13333
26666
mm
0
-100
-200
-300
-400
-500
Design Data
Capacity Reduction factor (phi) for Flexure
Capacity Reduction factor (phi) for Shear
Material Factor for Concrete in Flexure
Material Factor for Concrete in Shear
Material Factor for Reinforcement
Maximum Ratio of Neutral Axis Depth for Ductility
Ductility Limit - Strain
Ductility Check at Left End Column
Ductility Check at Right End Column
Minimum Reinforcement Strength Limit - #.## x M*
Flexural Critical Section - Consider Transverse Beams
Flexural Critical Section - Distance from centre of Support
Beam Left Sideface Cover (Internal)
Beam Right Sideface cover
Prestress Minimum Reinforcement Basis
Shear Enhancement at Supports
Ast Value in Shear Calculations
Limit Reinforcement Strain
#.#
#.#
#.#
#.#
#.#
#.#
#.#
Y/N
Y/N
#.#
Y/N
#.#
mm
mm
List
Y/N
List
Y/N
0.8
0.7
1
1
1
0.36
0
Y
Y
0
Y
-1
25
50
Program Default
N
Calculated
N
39999mm
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:27 AM
Page 5/26
License No.: 10155062180610WPN4
#.#
Y/N
Y/N
Y/N
Y/N
1
Y
Y
Y
N
Material Properties
Concrete
Description
Characteristic Compressive Strength
Mean Compressive Strength
Lower Characteristic Tensile Strength
Upper Characteristic Tensile Strength
Concrete Density
Design Concrete Modulus
Mean Concrete Modulus
Basic Shrinkage Strain
Shrinkage Multiplier
Basic Creep Factor
Concrete Strain at Peak Stress
Squash Load Factor
Concrete Strain Limit
40MPa 65MPa
40
65
48.51
75.78
3.79
4.84
6.83
8.71
2447
2447
31956.2 36745.3
33721.2 38517.8
1000
1000
1
1
2.8
2
0.002
0.003
0.9
0.9
0.004
0.003
Reinforcement Bar
Designation
Type
N Deformed
500
2e5
N 0.05
Description
Nominal
Bar
Bar
Bar Size Diameter Area
A
mm
mm2
10
10 78.5
12
12 113
16
16 201
20
20 314
24
24 452
Bar
Bar
Inertia Weight
mm4
kg/m
491.07 0.62
1018.29 0.89
3218.29 1.58
7857.14 2.47
16292.6 3.55
Stock
Length
mm
12000
12000
12000
12000
12000
540
90
-1
Material
Material Capacity
Include as
Capacity
Reduction Factor
Flexural
Reduction
- Shear
Reinforcement for
Factor - Flexure
Shear
-1
-1
-1
Y
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
Nominal
Bar
Bar Size Diameter
A
mm
28
28
32
32
36
36
40
40
Bar
Area
mm2
616
804
1020
1260
Bar
Bar
Inertia Weight
mm4
kg/m
30184 4.83
51492.6 6.31
82481.1 7.99
1.257e5 9.86
30/03/2012 10:35:27 AM
Page 6/26
License No.: 10155062180610WPN4
Stock
Length
mm
12000
12000
12000
12000
Elevation view
1
13333
26666
13333
26666
13333
26666
mm
0
-100
-200
-300
-400
-500
39999mm
Plan view
mm
-6000
-3000
0
3000
6000
39999mm
mm
2000
0
-2000
39999mm
Warnings
Input
No errors or warnings were found.
Output
Warning:SUPPORT Reinforcing Bar Spacing There have been problems in determining a bar size to satisfy the design spacing requirements.
See Detailed Reinforcement Design Comments.
Warning:Incremental Deflection span/deflection ratio in at least one span is less than defined limit.
Warning:Incremental deflection in at least one span is greater than defined limit.
Warning:Total deflection in at least one span is greater than defined limit.
Bending Moments
Load Cases
Column Actions
Col No. 1
Moment Above
Moment Below
Reaction
Elastic Rotation
Elastic Axial Shortening
kNm
kNm
kN
#.#
mm
Self
Live
Weight Load
104.07 2.21
125.71 2.67
893.3 19.01
1.9e-3
0
-0.3
-0
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
Col No. 2
Moment Above
Moment Below
Reaction
Elastic Rotation
Elastic Axial Shortening
Col No. 3
Moment Above
Moment Below
Reaction
Elastic Rotation
Elastic Axial Shortening
Col No. 4
Moment Above
Moment Below
Reaction
Elastic Rotation
Elastic Axial Shortening
30/03/2012 10:35:28 AM
Self
Live
Weight Load
kNm
-30.81 -0.66
kNm
-37.22 -0.79
kN
2279.04 48.49
#.# -5.63e-4
0
mm
-0.9
-0
Self
Live
Weight Load
kNm
30.81 0.66
kNm
37.22 0.79
kN
2279.04 48.49
#.#
5.63e-4
0
mm
-0.9
-0
Self
Live
Weight Load
kNm -104.07 -2.21
kNm -125.71 -2.67
kN
893.3 19.01
#.#
-1.9e-3
0
mm
-0.3
-0
Load Combinations
Column Actions
Col No. 1
Moment Above
Moment Below
Reaction
Elastic Rotation
Elastic Axial Shortening
Service
kNm
kNm
kN
#.#
mm
Col No. 2
Moment Above
Moment Below
Reaction
Elastic Rotation
Elastic Axial Shortening
Service
kNm
kNm
kN
#.#
mm
Col No. 3
Moment Above
Moment Below
Reaction
Elastic Rotation
Elastic Axial Shortening
Ultimate
Shear
Ultimate
Shear
(Reversal)
-29.42
-41.6
-35.54
-50.25
2062.03
3076.7
-5.38e-4
-7.6e-4
-0.8
-1.2
Service
kNm
kNm
kN
#.#
mm
Col No. 4
Moment Above
Moment Below
Reaction
Elastic Rotation
Elastic Axial Shortening
Service
kNm
kNm
kN
#.#
mm
-105.99
-128.03
907.28
-1.94e-3
-0.4
Service Ultimate
(Reversal) Flexure
-103.62
-125.17
891.78
-1.89e-3
-0.3
Page 7/26
License No.: 10155062180610WPN4
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:29 AM
Page 8/26
License No.: 10155062180610WPN4
Ultimate Flexure
1
kNm
-3200
-2400
-1600
-800 -118
0
800
1600
2400
-2567 -2528
-2528 -2567
-87.6
630
1695
1695
13333
1
kN
1600
1200 934
800
400
0
-400
-800
-1200
-1600
0
1115
924
-733
-924
-1115
13333
39999mm
26666
Shear : Column Strip 2
-886 -878
-878 -886
-30.7
420
1130
1130
13333
39999mm
26666
1
kNm
-3200
-2400
-1600
-800 0.038
0
800
1600
2400
26666
Moment : Middle Strip 2
419
354
-354
-419
13333
39999mm
26666
Shear : Middle Strip 2
-288
39999mm
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:30 AM
Page 9/26
License No.: 10155062180610WPN4
Flexural Design
Column Strip
Ultimate
2
18925
18925
6949
12165
6864
Bottom Total
kNm 1
-4000
-3200
-2400
-1600
-800
0
800
1600
2400
0
Bottom Ultimate
Min Top
13333
26666
39999mm
Final
3
13333
0.055
0.031
0.055
0.032
Initial
Min Bot
0.032
0.087
Top Ultimate
Ultimate Design
39999mm
26666
0.086
Capacity Minimum
0.1
0.08
0.06
0.04
0.02
0
-0.02
-0.04
-0.06
-0.08
12165
13333
0.086
0.087
mm2 1
25000
6949
20000
15000
10000
5000
0
-5000
-10000
-15000
26666
39999mm
Final
Service
Maximum Moment Condition
1
MPa
-8
-4
0
4
8
12
16
2
-7.45
-7.35
7.71
0
Gross Stress Top
3
-7.45
7.6
13333
7.71
39999mm
26666
Cracked Compression
Reinforcement Tension
MPa
-200
-100
0
100
200
300
400
Limits
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:31 AM
Page 10/26
License No.: 10155062180610WPN4
2
-7.26
-7.16
7.56
0
Gross Stress Top
7.56
39999mm
26666
Cracked Compression
MPa
-200
-100
0
100
200
300
400
-7.26
7.45
13333
Reinforcement Tension
Limits
Span 1
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
Span 2
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
Span 3
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
Permanent
Maximum Moment Condition
1
MPa
-8
-4
0
4
8
12
16
2
-7.32
-7.22
7.62
0
Gross Stress Top
7.62
39999mm
26666
Cracked Compression
MPa
-200
-100
0
100
200
300
400
-7.32
7.51
13333
Reinforcement Tension
Limits
2
-7.26
-7.16
7.56
0
Gross Stress Top
3
-7.26
7.45
13333
7.56
39999mm
26666
Cracked Compression
Reinforcement Tension
MPa
-200
-100
0
100
200
300
400
Limits
Span 1
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:31 AM
Page 11/26
License No.: 10155062180610WPN4
Span 2
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
Span 3
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
Middle Strip
Ultimate
4
6949
6864
13333
Bottom Ultimate
13333
26666
Initial
Min Bot
4
39999mm
Final
13333
0.032
0.032
0.031
0.032
0.08
Min Top
0.037
Top Ultimate
Ultimate Design
39999mm
0.037
Capacity Minimum
Bottom Total
8034
26666
0.032
kNm 1
-1600
-1200
-800
-400
0
400
800
1200
1600
0
0.1
0.08
0.06
0.04
0.02
0
-0.02
-0.04
-0.06
3
6949
8034
2
6949
0.032
1
mm2
6949
8000
6000
4000
2000
0
-2000
-4000
-6000
-8000
-10000
0
26666
39999mm
Final
Service
1
MPa
-4
-2
0
2
4
6
8
10
2
-3.38
-2.63
3.44
0
3
-3.38
2.67
13333
3.44
26666
MPa
-200
-100
0
100
200
300
400
500
39999mm
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:32 AM
Page 12/26
License No.: 10155062180610WPN4
2
-3.31
-2.59
3.37
0
3.36
39999mm
26666
Cracked Compression
MPa
-200
-100
0
100
200
300
400
500
-3.3
2.63
13333
Reinforcement Tension
Limits
Span 1
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
Span 3
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
Permanent
Maximum Moment Condition
1
MPa
-4
-2
0
2
4
6
8
10
2
-3.34
3.4
13333
Gross Stress Bottom
3.4
39999mm
26666
Cracked Compression
MPa
-200
-100
0
100
200
300
400
500
-3.34
2.65
0
Gross Stress Top
3
-2.61
Reinforcement Tension
Limits
2
-3.31
-2.59
3.37
0
Gross Stress Top
3
-3.3
2.63
13333
3.36
39999mm
26666
Cracked Compression
Reinforcement Tension
MPa
-200
-100
0
100
200
300
400
500
Limits
Span 1
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
Span 3
Design Comments:- Increase in stress from decompression to working exceeds 265MPa in at least one steel layer. Reinforcement has been added to reduce
stress change below this maximum value. Refer RAPT manual Section T.7.6
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:33 AM
Page 13/26
License No.: 10155062180610WPN4
Shear Design
Beam
Span 1
Locat
V*
mm
250
626
1077
1528
1979
2430
2881
3333.3
4444.3
5555.3
6666.5
7777.5
8888.5
9999.8
10450.8
10901.8
11352.8
11803.8
12254.8
12707
13083
kN
1100.21
933.86
795.71
672.42
562.49
464.41
376.67
297.55
131.3
-16.94
-154.89
-301.11
-456.09
-624.19
-697.14
-773.24
-852.78
-936.06
-1023.36
-1115.22
-1195.11
Mv*
Mdec
Ast
bv
kNm
kNm mm mm2
mm
kN
kN
kN
-35.15
0 416 6948.89 6666.5
0
0
0
332.65
0 421 6864.14 6666.5 1380.25 99999 1380.25
690.02
0 421 6864.14 6666.5 1380.25 99999 1380.25
970.81
0 421 6893.63 6666.5 1382.22 99999 1382.22
1187.71
0 421 8438.43 6666.5 1478.6 99999 1478.6
1352.02
0 421 9624.56 6666.5 1544.86 99999 1544.86
1473.72
0 421 10518.5 6666.5 1591.28 99999 1591.28
1561.59
0 421 11166 6666.5 1623.28 99999 1623.28
1674.99
0 421 12008.2 6666.5 1663.11 99999 1663.11
1514.03
0 421 12165.1 6666.5 1670.32 99999 1670.32
1610.54
0 421 11548.4 6666.5 1641.61 99999 1641.61
1380.44
0 421 9868.74 6666.5 1557.82 99999 1557.82
990.14
0 421 7078.69 6666.5 1394.48 99999 1394.48
415.07
0 421 6864.14 6666.5 1380.25 99999 1380.25
121.52
0 421 6864.14 6666.5 1380.25 99999 1380.25
-210.67
0 416 6948.89 6666.5 1380.74 99999 1380.74
-584.49
0 416 6948.89 6666.5 1380.74 99999 1380.74
-1003.19
0 416 7232.35 6666.5 1399.27 99999 1399.27
-1470.27
0 416 10640 6666.5 1591.43 99999 1591.43
-1991.01
0 416 14541.2 6666.5 1766.07 99999 1766.07
-2466.8
0 416 18166.2 6666.5
0
0
0
Asv/s
kN
mm2/mm
25236.7
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
Spacing of Sets
2 legs
2 legs
2 legs
N10
N12
N16
mm
mm
mm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
A
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
Span 2
Locat
V*
Mv*
Mdec
Ast
bv
mm
kN
kNm
kNm mm mm2
mm
kN
kN
kN
250 1002.81 -2441.21
0 416 17973.5 6666.5
0
0
0
626 923.85 -2030.81
0 416 14837.5 6666.5 1777.99 99999 1777.99
1077 833.95 -1589.81
0 416 11520.7 6666.5 1634.18 99999 1634.18
1528 748.91 -1200.42
0 416 8644.22 6666.5 1484.96 99999 1484.96
1979 668.35 -858.44
0 416 6948.89 6666.5 1380.74 99999 1380.74
2430 591.88
-560
0 416 6948.89 6666.5 1380.74 99999 1380.74
2881 519.09 -301.59
0 416 6948.89 6666.5 1380.74 99999 1380.74
3333.3 449.42
-79.5
0 416 6948.89 6666.5 1380.74 99999 1380.74
4444.3 289.83 325.59
0 421 6864.14 6666.5 1380.25 99999 1380.25
5555.3 141.99
555.6
0 421 6864.14 6666.5 1380.25 99999 1380.25
6666.5
-7.59 567.56
0 421 6864.14 6666.5 1380.25 99999 1380.25
7777.5 -141.96 555.64
0 421 6864.14 6666.5 1380.25 99999 1380.25
8888.5
-289.8 325.66
0 421 6864.14 6666.5 1380.25 99999 1380.25
Asv/s
kN
mm2/mm
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25540
0
25540
0
25540
0
25540
0
25540
0
Spacing of Sets
2 legs
2 legs
2 legs
N10
N12
N16
mm
mm
mm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
Locat
V*
mm
kN
9999.8 -449.42
10450.8 -518.89
10901.8 -591.67
11352.8 -668.13
11803.8 -748.68
12254.8
-833.7
12707 -923.85
13083 -1002.81
Mv*
Mdec
30/03/2012 10:35:34 AM
Ast
bv
Page 14/26
License No.: 10155062180610WPN4
kNm
kNm mm mm2
mm
kN
kN
kN
-79.5
0 416 6948.89 6666.5 1380.74 99999 1380.74
-300.93
0 416 6948.89 6666.5 1380.74 99999 1380.74
-559.23
0 416 6948.89 6666.5 1380.74 99999 1380.74
-857.56
0 416 6948.89 6666.5 1380.74 99999 1380.74
-1199.41
0 416 8636.76 6666.5 1484.54 99999 1484.54
-1588.66
0 416 11512.1 6666.5 1633.78 99999 1633.78
-2030.81
0 416 14837.5 6666.5 1777.99 99999 1777.99
-2441.21
0 416 17973.5 6666.5
0
0
0
Asv/s
kN
mm2/mm
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
Spacing of Sets
2 legs
2 legs
2 legs
N10
N12
N16
mm
mm
mm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
A
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
Span 3
Locat
V*
mm
250
626
1077
1528
1979
2430
2881
3333.3
4444.3
5555.3
6666.5
7777.5
8888.5
9999.8
10450.8
10901.8
11352.8
11803.8
12254.8
12707
13083
kN
1195.11
1115.22
1023.6
936.29
853.01
773.45
697.34
624.19
456.13
301.14
154.89
16.97
-129.14
-279.63
-344.98
-413.64
-486.18
-563.16
-645.15
-732.96
-810.64
Mv*
Mdec
A
0
0
Ast
bv
kNm
kNm mm mm2
mm
kN
kN
kN
-2466.8
0 416 18166.2 6666.5
0
0
0
-1991.01
0 416 14541.2 6666.5 1766.07 99999 1766.07
-1471.63
0 416 10650.1 6666.5 1591.94 99999 1591.94
-1004.41
0 416 7241.15 6666.5 1399.83 99999 1399.83
-585.59
0 416 6948.89 6666.5 1380.74 99999 1380.74
-211.65
0 416 6948.89 6666.5 1380.74 99999 1380.74
120.65
0 421 6864.14 6666.5 1380.25 99999 1380.25
415.07
0 421 6864.14 6666.5 1380.25 99999 1380.25
990.03
0 421 7077.9 6666.5 1394.43 99999 1394.43
1380.37
0 421 9868.21 6666.5 1557.79 99999 1557.79
1610.53
0 421 11548.4 6666.5 1641.61 99999 1641.61
1514.02
0 421 12165.1 6666.5 1670.32 99999 1670.32
1647.83
0 421 11807.4 6666.5 1653.79 99999 1653.79
1467.53
0 421 10474.6 6666.5 1589.06 99999 1589.06
1350.83
0 421 9617.25 6666.5 1544.47 99999 1544.47
1205.25
0 421 8567.21 6666.5 1486.08 99999 1486.08
1027.56
0 421 7293.21 6666.5 1408.43 99999 1408.43
814.03
0 421 6864.14 6666.5 1380.25 99999 1380.25
560.42
0 421 6864.14 6666.5 1380.25 99999 1380.25
261.09
0 421 6864.14 6666.5 1380.25 99999 1380.25
-25.9
0 416 6948.89 6666.5
0
0
0
No shear steel
Asv/s
kN
mm2/mm
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25236.7
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25540
0
25236.7
0
Spacing of Sets
2 legs
2 legs
2 legs
N10
N12
N16
mm
mm
mm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:35 AM
Page 15/26
License No.: 10155062180610WPN4
#
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
A
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
No shear steel
Punching
Column Head Critical Section
Column Bh
a
No.
A
#.# mm
1
1 710.5
2
1
916
3
1
916
4
1 710.5
Asw/s reqd
at
mm
470
470
470
470
u
mm
2342
3664
3664
2342
d
mm
421
416
416
421
fcv
V*
Mv*
phi Vuo
phi
side Moment
Vumax beam Transfer
kN
A
A
3469.4 No
Yes
7080.51 No
Yes
7080.51 No
Yes
3469.4 No
Yes
result
mm2/mm
A
0
OK
0.34 O K with Ties
0.34 O K with Ties
0
OK
Deflections
Live Load on All Spans
Transfer
mm
0
1.45
-30
-17.7
-20.3
-60
-90
-120
654
0
Column Strip Live Load on All Spans
9159
13333
Middle Strip Live Load on All Spans
753
26666
39999mm
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:35 AM
Page 16/26
License No.: 10155062180610WPN4
Short Term
mm
0
1.36
-30
-18.2
-18.6
-60
-90
-120
714
0
9782
13333
733
39999mm
26666
Middle Str
Incremental
mm
0
-3.8
-30
-25.5
-26.7
-60
-90
-120
521
0
3504
13333
499
39999mm
26666
Middle Str
-4.9
-30
-42.6
-43.6
-60
-90
-120
305
0
2713
13333
312
26666
Span 1
Design Comments:- Incremental Deflection greater than user defined limit = -25.5mm
- Total Deflection greater than user defined limit = -43.6mm
Span 3
Design Comments:- Incremental Span/Deflection ratio less than user defined limit = 499
- Incremental Deflection greater than user defined limit = -26.7mm
- Total Deflection greater than user defined limit = -42.6mm
39999mm
Middle Str
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:36 AM
Page 17/26
License No.: 10155062180610WPN4
1.45
-30
-17.7
-20.3
-60
-90
-120
654
0
9159
13333
753
39999mm
26666
Short Term
mm
0
-1.32
-15.8
-17.8
-30
-60
-90
-120
749
0
10103
13333
844
39999mm
26666
Middle Str
Incremental
mm
0
-4.01
-30
-24.2
-24.6
-60
-90
-120
540
0
3315
13333
549
39999mm
26666
Middle Str
-5.13
-30
-40
-42.7
-60
-90
-120
312
0
Column Strip Live Load on All Spans
2595
13333
Column Strip Live Load on Odd Spans
Span 1
Design Comments:- Total Deflection greater than user defined limit = -42.7mm
Span 3
Design Comments:- Total Deflection greater than user defined limit = -40mm
332
26666
39999mm
Middle Str
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:37 AM
Page 18/26
License No.: 10155062180610WPN4
#
mm
#
mm
mm
#
mm
mm
#
mm
mm
#
mm
1
2
3
-20.3
1.5 -17.7
654
9159
753
5555.3 11803.8 7777.5
-18.8
1.4 -18.3
707
9403
725
5555.3 11803.8 7777.5
-25.6
-3.6 -26.7
519
3690
499
6666.5 6666.5 7777.5
-43.7
-4.7 -42.6
304
2819
312
5555.3 6666.5 7777.5
#
mm
#
mm
mm
#
mm
mm
#
mm
mm
#
mm
1
-9.3
1424
5555.3
-8.8
1514
5555.3
-18.2
730
5555.3
-26.8
496
5555.3
Middle Strip
Span
Deflection
Span/Defection
Locat
Deflection
Short Term
Span/Defection
Locat
Deflection
Incremental
Span/Defection
Locat
Deflection
Total Long Term
Span/Defection
Locat
Transfer
2
-1.6
8314
6666.5
-1.4
9783
6666.5
-3.7
3591
6666.5
-5.2
2569
6666.5
3
-9.7
1371
7777.5
-9.1
1458
7777.5
-18.8
707
7777.5
-27.8
479
7777.5
Span 1
Design Comments:- Incremental Deflection greater than user defined limit = -25.6mm
- Total Deflection greater than user defined limit = -43.7mm
Span 3
Design Comments:- Incremental Span/Deflection ratio less than user defined limit = 499
- Incremental Deflection greater than user defined limit = -26.7mm
- Total Deflection greater than user defined limit = -42.6mm
Transfer
mm
0
1.45
-30
-17.7
-20.3
-60
-90
-120
654
0
Column Strip Live Load on Odd Spans
9159
13333
Middle Strip Live Load on Odd Spans
753
26666
39999mm
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:38 AM
Page 19/26
License No.: 10155062180610WPN4
Short Term
mm
0
1.41
-30
-18.3
-18.8
-60
-90
-120
707
0
9403
725
13333
39999mm
26666
Middle Str
Incremental
mm
0
-3.61
-30
-25.6
-26.7
-60
-90
-120
519
0
3690
499
13333
39999mm
26666
Middle Str
-4.72
-30
-42.6
-43.7
-60
-90
-120
304
0
2819
312
13333
39999mm
26666
Span 1
Design Comments:- Incremental Deflection greater than user defined limit = -25.6mm
- Total Deflection greater than user defined limit = -43.7mm
Span 3
Design Comments:- Incremental Span/Deflection ratio less than user defined limit = 499
- Incremental Deflection greater than user defined limit = -26.7mm
- Total Deflection greater than user defined limit = -42.6mm
Detailed Reinforcement
Column Strip - Span 1
Top Reinforcement
Max Max
Section
Max Max
Size Space
Locat Size Space Area Depth Width
Rebar Reqd
mm
mm mm
mm2
mm
mm
A
mm mm
175 40
300 6948.89
54 6666.5 35 N16 @ 192.8
0
0
250 40
300 6948.89
54 6666.5 35 N16 @ 192.8
0
0
626
0
0
0
54 6666.5 No Steel Added 40
300
1077
0
0
0
54 6666.5 No Steel Added 24 264.3
1528
0
0
0
54 6666.5 No Steel Added 16 171.1
1979
0
0
0
54 6666.5 No Steel Added 16 169.8
2430
0
0
0
54 6666.5 No Steel Added 16 169.2
2881
0
0
0
54 6666.5 No Steel Added 16 169.2
Bottom Reinforcement
Area
mm2
Depth
mm
0 421
0 421
6864.14 421
6864.14 421
7197.74 421
8438.43 421
9624.56 421
10518.5 421
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Rebar Reqd
A
No Steel Added
No Steel Added
35 N16 @ 195.2
35 N16 @ 195.2
36 N16 @ 186.2
42 N16 @ 158.8
48 N16 @ 139.2
53 N16 @ 127.4
Middle Str
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:39 AM
Top Reinforcement
Page 20/26
License No.: 10155062180610WPN4
Bottom Reinforcement
Max Max
Section
Max Max
Size Space
Locat Size Space Area Depth Width
Rebar Reqd
mm
mm mm
mm2
mm
mm
A
mm mm
3333.3
0
0
0
54 6666.5 No Steel Added 16 169.2
4444.3
0
0
0
54 6666.5 No Steel Added 16 169.2
5555.3
0
0
0
54 6666.5 No Steel Added 16 169.2
6666.5
0
0
0
54 6666.5 No Steel Added 16 169.2
7777.5
0
0
0
54 6666.5 No Steel Added 16 169.1
8888.5
0
0
0
54 6666.5 No Steel Added 16 170.7
9999.8
0
0
0
54 6666.5 No Steel Added 40
300
10450.8
0
0
0
54 6666.5 No Steel Added 40
300
10901.8 40
300 6948.89
54 6666.5 35 N16 @ 192.8
0
0
11352.8 28
298 6948.89
54 6666.5 35 N16 @ 192.8
0
0
11803.8 16 170.7 9137.6
54 6666.5 46 N16 @ 146.6
0
0
12254.8 16 169.1 12414.6
54 6666.5 62 N16 @ 107.9
0
0
12707 16 169.4 15942.2
54 6666.5 80 N16 @ 84.1
0
0
13083 16
170 18166.2
54 6666.5 91 N16 @ 73.8
0
0
13158 16
170 18924.7
54 6666.5 95 N16 @ 70.8
0
0
Shear Reinforcement
Spacing of Sets
2 legs
2 legs
2 legs
Shear
Area
N10
N12
N16
Comments
mm2/mm
mm
mm
mm
A
0
0
0
0
0
0
0
0
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0
0
0
0
0
Area Depth
mm2
mm
11166 421
12008.2 421
12165.1 421
11548.4 421
9868.74 421
7078.69 421
6864.14 421
6864.14 421
0 421
0 421
0 421
0 421
0 421
0 421
0 421
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Rebar Reqd
A
56 N16 @ 120
60 N16 @ 111.6
61 N16 @ 110.1
58 N16 @ 116
50 N16 @ 135.8
36 N16 @ 189.3
35 N16 @ 195.2
35 N16 @ 195.2
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
Design Comments:- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 2 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- Span - 1 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 2282.19mm2 - Column Strip
- Span - 1 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1664.38mm2 - Column Strip
Area Depth
mm2
mm
18633.7
54
17973.5
54
15694.3
54
12655.5
54
9863.89
54
7424.89
54
6948.89
54
6948.89
54
6948.89
54
0
54
0
54
0
54
0
54
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Bottom Reinforcement
Max Max
Rebar Reqd
Size Space
A
mm mm
93 N16 @ 71.9
0
0
90 N16 @ 74.6
0
0
79 N16 @ 85.4
0
0
63 N16 @ 105.9
0
0
50 N16 @ 135.8
0
0
37 N16 @ 180.5
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
No Steel Added 40
300
No Steel Added 32
300
No Steel Added 28 279.9
No Steel Added 32
300
Area
mm2
Depth
mm
0 421
0 421
0 421
0 421
0 421
0 421
0 421
0 421
0 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Rebar Reqd
A
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:39 AM
Top Reinforcement
Page 21/26
License No.: 10155062180610WPN4
Bottom Reinforcement
Max Max
Section
Max Max
Section
Size Space Area Depth Width
Locat Size Space Area Depth Width
Rebar Reqd
Rebar Reqd
mm
mm mm
mm2
mm
mm
A
mm mm
mm2
mm
mm
A
8888.5
0
0
0
54 6666.5 No Steel Added 40
300 6864.14 421 6666.5 35 N16 @ 195.2
9999.8 40
300 6948.89
54 6666.5 35 N16 @ 192.8
0
0
0 421 6666.5 No Steel Added
10450.8 40
300 6948.89
54 6666.5 35 N16 @ 192.8
0
0
0 421 6666.5 No Steel Added
10901.8 32
300 6948.89
54 6666.5 35 N16 @ 192.8
0
0
0 421 6666.5 No Steel Added
11352.8 20
205 7418.59
54 6666.5 37 N16 @ 180.6
0
0
0 421 6666.5 No Steel Added
11803.8 16 169.8 9856.68
54 6666.5 50 N16 @ 135.9
0
0
0 421 6666.5 No Steel Added
12254.8 16 169.2 12646.8
54 6666.5
63 N16 @ 106
0
0
0 421 6666.5 No Steel Added
12707 16 169.5 15694.3
54 6666.5 79 N16 @ 85.4
0
0
0 421 6666.5 No Steel Added
13083 16
170 17973.5
54 6666.5 90 N16 @ 74.6
0
0
0 421 6666.5 No Steel Added
13158 16
170 18633.7
54 6666.5 93 N16 @ 71.9
0
0
0 421 6666.5 No Steel Added
Shear Reinforcement
Spacing of Sets
2 legs
2 legs
2 legs
Shear
Area
N10
N12
N16
Comments
mm2/mm
mm
mm
mm
A
0
0
0
0
0
0
0
0
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0
0
0
0
0
Design Comments:- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 2 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 3 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- Span - 2 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 939.16mm2 - Column Strip
- Span - 2 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 939.16mm2 - Column Strip
Area Depth
mm2
mm
18924.7
54
18166.2
54
15942.2
54
12424.7
54
9146.12
54
6948.89
54
6948.89
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Bottom Reinforcement
Max Max
Rebar Reqd
Size Space
A
mm mm
95 N16 @ 70.8
0
0
91 N16 @ 73.8
0
0
80 N16 @ 84.1
0
0
62 N16 @ 107.8
0
0
46 N16 @ 146.5
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
No Steel Added 40
300
No Steel Added 40
300
No Steel Added 16 170.7
No Steel Added 16 169.1
No Steel Added 16 169.2
No Steel Added 16 169.2
No Steel Added 16 169.2
No Steel Added 16 169.2
Area
mm2
Depth
mm
0 421
0 421
0 421
0 421
0 421
0 421
0 421
6864.14 421
6864.14 421
7077.9 421
9868.21 421
11548.4 421
12165.1 421
11807.4 421
10474.6 421
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Rebar Reqd
A
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
35 N16 @ 195.2
35 N16 @ 195.2
36 N16 @ 189.3
50 N16 @ 135.8
58 N16 @ 116
61 N16 @ 110.1
59 N16 @ 113.5
53 N16 @ 127.9
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:40 AM
Top Reinforcement
Page 22/26
License No.: 10155062180610WPN4
Bottom Reinforcement
Max Max
Section
Max Max
Size Space
Locat Size Space Area Depth Width
Rebar Reqd
mm
mm mm
mm2
mm
mm
A
mm mm
10450.8
0
0
0
54 6666.5 No Steel Added 16 169.2
10901.8
0
0
0
54 6666.5 No Steel Added 16 169.8
11352.8
0
0
0
54 6666.5 No Steel Added 16 170.5
11803.8
0
0
0
54 6666.5 No Steel Added 20 221.3
12254.8
0
0
0
54 6666.5 No Steel Added 32
300
12707
0
0
0
54 6666.5 No Steel Added 40
300
13083 40
300 6948.89
54 6666.5 35 N16 @ 192.8
0
0
13158 40
300 6948.89
54 6666.5 35 N16 @ 192.8
0
0
Shear Reinforcement
Spacing of Sets
2 legs
2 legs
2 legs
Shear
Area
N10
N12
N16
Comments
mm2/mm
mm
mm
mm
A
0
0
0
0
0
0
0
0
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0 No shear steel
0
0
0
0
0
0
0
0
Area Depth
mm2
mm
9617.25 421
8567.21 421
7300.19 421
6864.14 421
6864.14 421
6864.14 421
0 421
0 421
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Rebar Reqd
A
48 N16 @ 139.3
43 N16 @ 156.4
37 N16 @ 183.6
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
No Steel Added
No Steel Added
Design Comments:- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 3 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- Span - 3 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 1664.36mm2 - Column Strip
- Span - 3 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1799.82mm2 - Column Strip
Area Depth
mm2
mm
6948.89
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
0
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Bottom Reinforcement
Max Max
Rebar Reqd
Size Space
A
mm mm
35 N16 @ 192.8 40
300
No Steel Added 40
300
No Steel Added 40
300
No Steel Added 40
300
No Steel Added 40
300
No Steel Added 40
300
No Steel Added 36
300
No Steel Added 28 276.5
No Steel Added 20 229.3
No Steel Added 16 170.4
No Steel Added 16
170
No Steel Added 16 170.3
No Steel Added 20 199.4
No Steel Added 28 297.4
No Steel Added 40
300
No Steel Added 40
300
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
Area Depth
mm2
mm
4466.56 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
7417.59 421
8033.81 421
7541.49 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
0 421
0 421
0 421
0 421
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Rebar Reqd
A
23 N16 @ 300
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
37 N16 @ 180.6
40 N16 @ 166.8
38 N16 @ 177.7
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
No Steel Added
No Steel Added
No Steel Added
No Steel Added
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
30/03/2012 10:35:41 AM
Top Reinforcement
Page 23/26
License No.: 10155062180610WPN4
Bottom Reinforcement
Max Max
Section
Max Max
Size Space
Locat Size Space Area Depth Width
Rebar Reqd
mm
mm mm
mm2
mm
mm
A
mm mm
12707 24 243.4 6948.89
54 6666.5 35 N16 @ 192.8
0
0
13083 20 203.7 6948.89
54 6666.5 35 N16 @ 192.8
0
0
13158 16 196.2 6948.89
54 6666.5 35 N16 @ 192.8
0
0
Shear Reinforcement
Spacing of Sets
2 legs
2 legs
2 legs
Shear
N10
N12
N16 Comments
Area
mm2/mm
mm
mm
mm
A
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Area
mm2
Depth
mm
0 421
0 421
0 421
Section
Width
mm
6666.5
6666.5
6666.5
Rebar Reqd
A
No Steel Added
No Steel Added
No Steel Added
Design Comments:- Span - 1 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 0.02mm2 - Middle Strip
- Span - 1 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1450.05mm2 - Middle Strip
Area Depth
mm2
mm
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
0
54
0
54
0
54
0
54
0
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
6948.89
54
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Bottom Reinforcement
Max Max
Size Space
Rebar Reqd
A
mm mm
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
No Steel Added 40 300
No Steel Added 40 300
No Steel Added 40 300
No Steel Added 40 300
No Steel Added 40 300
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
35 N16 @ 192.8
0
0
Area
mm2
Depth
mm
0 421
0 421
0 421
0 421
0 421
0 421
0 421
0 421
0 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
0 421
0 421
0 421
0 421
0 421
0 421
0 421
0 421
0 421
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Rebar Reqd
A
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
Area
mm2/mm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
30/03/2012 10:35:42 AM
Page 24/26
License No.: 10155062180610WPN4
Shear Reinforcement
Spacing of Sets
2 legs
2 legs
2 legs
Shear
N10
N12
N16 Comments
mm
mm
mm
A
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Design Comments:- Span - 2 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 867.29mm2 - Middle Strip
- Span - 2 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 867.28mm2 - Middle Strip
Bottom Reinforcement
Area
mm2
Depth
mm
0 421
0 421
0 421
0 421
0 421
0 421
0 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
7541.51 421
8033.79 421
7611.08 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
6864.14 421
0 421
0 421
Section
Width
mm
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
6666.5
Rebar Reqd
A
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
No Steel Added
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
38 N16 @ 177.7
40 N16 @ 166.8
38 N16 @ 176.1
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
35 N16 @ 195.2
No Steel Added
No Steel Added
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
Area
mm2/mm
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
30/03/2012 10:35:43 AM
Page 25/26
License No.: 10155062180610WPN4
Shear Reinforcement
Spacing of Sets
2 legs
2 legs
2 legs
Shear
N10
N12
N16 Comments
mm
mm
mm
A
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
Design Comments:- Span - 3 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 1450.05mm2 - Middle Strip
- Span - 3 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1217.9mm2 - Middle Strip
Reinforcement Layout
Column Strip
Bar
Layer
No. Type Size
#
1
2
3
4
5
6
7
A
A
N500 16
N500 16
N500 16
N500 16
N500 16
N500 16
N500 16
Design Comments:- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 2 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- Span - 1 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 2282.19mm2 - Column Strip
- Span - 1 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1664.38mm2 - Column Strip
- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 2 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 3 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- Span - 2 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 939.16mm2 - Column Strip
- Span - 2 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 939.16mm2 - Column Strip
- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 3 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- Span - 3 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 1664.36mm2 - Column Strip
- Span - 3 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1799.82mm2 - Column Strip
Middle Strip
Bar
Layer
No. Type Size
#
1
2
3
4
A
A
N500 16
N500 16
N500 16
N500 16
RAPT 6.3.2.0
Licensee: Alliance Design Group Pty Ltd
Bar
Layer
No. Type Size
#
A
A
5 N500 16
6 N500 16
7 N500 16
30/03/2012 10:35:44 AM
Page 26/26
License No.: 10155062180610WPN4
Design Comments:- Span - 1 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 0.02mm2 - Middle Strip
- Span - 1 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1450.05mm2 - Middle Strip
- Span - 2 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 867.29mm2 - Middle Strip
- Span - 2 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 867.28mm2 - Middle Strip
- Span - 3 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 1450.05mm2 - Middle Strip
- Span - 3 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1217.9mm2 - Middle Strip
Column Strip
35-N16
95-N16
95-N16
35-N16
1
mm
0
-100
-200
-500
0
13333
26666
61-N16
61-N16
-400
35-N16
-300
39999mm
- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 2 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
Design Comments:- Span - 1 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 2282.19mm2 - Column Strip
- Span - 1 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1664.38mm2 - Column Strip
- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 2 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 3 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- Span - 2 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 939.16mm2 - Column Strip
- Span - 2 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 939.16mm2 - Column Strip
- SUPPORT Reinforcing Bar Spacing - Column Strip - Column Grid 3 - Largest preferred reinforcement size requires bar spacing smaller
then minimum. It will be necessary to use larger bars than the preferred maximum size, place more reinforcement in the flange if possible or
place reinforcement in multiple layers.
- Span - 3 - Reinforcement added at left contraflexure point for Offset of Bending Moment Diagram for Shear - 1664.36mm2 - Column Strip
- Span - 3 - Reinforcement added at right contraflexure point for Offset of Bending Moment Diagram for Shear - 1799.82mm2 - Column Strip
35-N16
35-N16
35-N16
35-N16
1
mm
0
-100
-200
13333
26666
40-N16
-500
35-N16
-400
40-N16
-300