Anda di halaman 1dari 136

Greenheck Quick Delivery Greenheck Quick Delivery

Stock & Quick Build Catalog & Quick Build Catalog


Volume 23 Volume 23

3,000

Ventilation Products Available In-stock or on Quick Build Program

Whats NEW?
Make-Up Air & Lab Exhaust Models

This catalog is being sent to you on behalf of:

Roof Mounted Fans


Model G Model GB Models LD/LDP Models LB/LBP Models CUE/CUE-HP Model CUBE Model USGF Models CW/CW-HP/CWB/CWB-HP Models RDU/RBU/RBUMO Models RGU Models TAUD/TAUB/TAUB-CA Model SAF Models RSF/RSFP Models R/RB Models RPDR/RPBR Models AE/AS

Page(s)
4-5 6-9 10 11 12-13 14-17 18 19-21 22-23 24 25-26 27-28 29-30 31-32 33-34 35 36 37

ROOF MOUNTED FANS & GRAVITY VENTILATORS

Gravity Ventilators
Model GRS/GRSF Models FGI/FGR

ROOF CURBS

Roof Curbs
Roof Curbs & Extensions 38-39

Ceiling and Cabinet Fans


Model SP Model CSP 40-41 42-43 44-47 48 49 50-53 54-55 56 57 58-59 60-61 62 63-68 69 69

INLINE, CEILING & SIDEWALL EXHAUST FANS

SP/CSP Accessories

Inline Fans
Model BCF Model BDF Model SQ/BSQ Inline Fans Accessories Model TCB Model TCF Model QEI Models TDI/TBI-FS/TBI-CA Model VAB

Sidewall Exhaust Fans


Models S/SB Model CBF Model DF

Utility Fans UTILITY, CENTRIFUGAL & RADIAL BLOWERS


Models SFD/SFB Model SWB 70-71 72-75 77 78 79

Centrifugal Fans
Models BISW/AFSW/BIDW/AFDW

Radial Blowers
Models IPO/IPW/IPA

Plenum Fan
Model QEP

Vektor Laboratory Exhaust Systems LAB EXHAUST SYSTEMS


Vektor-H 80-81

Kitchen Ventilation
Type I Kitchen Hoods Type II Kitchen Hoods

Page(s)
82 83

KITCHEN VENTILATION

Energy Recovery Ventilators


Model ERV Model Minivent-450/750 84-85 85

ENERGY RECOVERY, MAKE-UP AIR, INDOOR AIR HANDLERS, FAN COILS, UNDERFLOOR FANS, COILS

Make-Up Air Systems


Models DGK/DG/DGx Models IG/IGx Models KSFD/KSFB 86-87 88-89 90-91

Indoor Air Handlers and Fan Coils


Model VFCB/VFCD Model HFCB/HFCD Model LFC Model MSCF 92-93 94-95 96 & 98 97-98

Underfloor Fan Distribution


Model UFT 99

Coils
Custom Coils 100

Dampers
Curtain and Multi-Blade Fire Dampers Smoke Dampers Fire Smoke Dampers Access Doors Marine Dampers Ceiling Radiation Dampers Volume Control Dampers Insulated Control Dampers Manual Balancing Dampers Industrial Dampers Barometric Relief Dampers Backdraft Dampers 101 102 103-104 105 105 106 107 108 108 109 109 110

DAMPERS

Louvers
Drainable Blade & Drainable Head Nondrainable, Recessed Mullion & Thinline Adjustable Blade & Combination Louvers/Dampers Sightproof & Acoustical Fabricated & Wind-Driven Rain Florida Product Approved/Miami-Dade Louvered Penthouses Brick Vents
MARBLE IVORy SPARTAN WHITE DESERT SAND HAMPTON BROWN

111 112

LOUVERS

113 114 115 116 117 117

Options and Accessories


TAUPE

OPTIONS

Mounting Options Coatings Electrical Accessories Replacement Parts

118 119 120 120

MEDIUM BRONZE

CLASSIC BRONZE

Fan Fundamentals and Representatives Directory


Fan Fundamentals Greenheck Representatives Directory 121-125 126-134

FAN FUNDAMENTALS & REP DIRECTORY

Roof Mounted Fans and Gravity Ventilators


Roof Exhaust Direct Drive - G
Model G centrifugal roof exhaust fans are direct drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels are centrifugal, backward-inclined, and constructed of aluminum.
B

PERFORMANCE
Performance capabilities range from 73 cfm to 4,295 cfm and up to 1in.wg of static pressure.

C*

1 3/4 in. A

n Performance for available in stock sizes is shown on page 5 MODEL G-060 G-065 G-070 G-075 G-080 G-085 G-090 G-095 G-101 G-121 G-131 G-141 G-150 G-160 G-170 G-180 A 17 17 17 17 17 17 17 17 19 19 22 22 26 30 30 30 B 1938 19 8
3

C* 1218 12 8
1

ROOF OPENING 1012 x 1012 10 2 x 10 2


1 1

DAMPER SIZE

IN STOCK SIZES (n) n n

8x8 19 8
3

12 8
1

10 2 x 10 2
1 1

n n n n 10 x 10 n n n 12 x 12 n n 16 x 16 n n n 18 x 18

1938 2134 2134 2134 21 4


3

1218 1458 1458 1458 14 8


5

1012 x 1012 1212 x 1212 1212 x 1212 1212 x 1212 12 2 x 12 2


1 1

24 8
5

20 20 20 20 2118 2158 2158 2234

14 2 x 14 2
1 1

2458 2878 2878 3512 3512 3512 3512

1412 x 1412 1812 x 1812 1812 x 1812 1812 x 1812 2012 x 2012 2012 x 2012 2012 x 2012

MIN/MAX RPM 1050 1550 1050 1550 1050 1550 1050 1550 1050 1550 1050 1550 1050 1550 1050 1550 860 1725 860 1725 860 1725 860 1140 860 1140 860 1140 860 1140 860 1140

SONES @ 0 IN. 1.7 4.2 2.2 4.9 2.7 5.6 3.6 6.1 3.8 7.3 4.0 7.6 4.0 7.6 5.4 9.6 4.3 12.1 5.6 14.1 6.5 19.2 6.8 10.4 7.9 11.7 8.0 13.6 9.7 16.3 12.1 19.5

PERFORMANCE 0 .125 .25 138 73 203 166 120 187 110 276 232 176 254 179 374 327 274 296 200 438 377 310 335 249 134 495 439 379 399 307 179 588 529 464 520 420 292 768 700 633 717 569 389 1059 969 863 766 588 239 1536 1454 1374 922 723 449 1849 1753 1659 1193 1011 771 2393 2310 2222 1376 1160 919 1824 1667 1498 1772 1552 1305 2348 2184 2016 2008 1783 1535 2662 2489 2319 2572 2329 2077 3409 3226 3042 3240 3002 2733 4295 4122 3933

IN INCHES WG .5 .75 1

238 308 472 623 1181 974

1453 1223 2030 1820 1555 1112 1629 552 1932 1417 2647 1978 3509 1115 1411 2182 1458 2971 2247

*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information refer to catalog Model G and GB, or contact your local representative.

Greenheck Fan Corporation certifies that the Model G fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

ROOF MOUNTED FANS

Roof Exhaust Direct Drive - G


SERVICE CHART
Sizes G-060 through 160 Sizes G-170 & G-180

IN STOCK

NEXT DAY

3 DAY

10 DAY

OPTIONS AND ACCESSORIES


Gravity and motorized dampers (In Stock) Galvanized roof curbs (In Stock) Aluminum roof curbs (See pages 38-39) Extended bases Insect screen bases Aluminum birdscreen Curb seal Hinged curb cap w/cable Curb adaptors Tie-down points Speed controls (In Stock) UL/cUL 705 Electrical NEMA-3R and EXP disconnect switches High wind Greenheck coatings (See coatings page 19) 1

STANDARD CONSTRUCTION FEATURES


Aluminum housing Non-overloading backward-inclined wheel Aluminum curb cap with prepunched mounting holes Integral reinforced bead for strength on hood Galvanized birdscreen Ball bearing motors (sizes 101-180), sleeve bearing motors (sizes 060-095) Double-studded isolators for true vibration isolation Corrosion-resistant fasteners NEMA-1 disconnect

G PERFORMANCE DATA - IN STOCK


MODEL G-060-DGEX-QD 1/60 HP 3 Speed G-065-DGEX-QD 1/30 HP 3 Speed G-070-DGEX-QD 1/30 HP 3 Speed G-075-DGEX-QD 1/25 HP 3 Speed G-080-DGEX-QD 1/20 HP 3 Speed G-085-DGEX-QD 1/20 HP 3 Speed G-090-DGEX-QD 1/15 HP 3 Speed G-095-DGEX-QD 1/8 HP 3 Speed G-101-BX-QD 1/6 HP G-101-AX-QD 1/4 HP G-121-BX-QD 1/6 HP G-121-AX-QD 1/4 HP G-131-BX-QD 1/6 HP G-141-BX-QD 1/6 HP G-150-BX-QD 1/4 HP G-160-BX-QD 1/3 HP E G D E G D E G D E G D E G D E G D E G D E G D RPM 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1140 1725 1140 1725 1140 1140 1140 1140 TS 2234 2765 3297 2234 2765 3297 2234 2765 3297 2234 2765 3297 2990 3701 4413 2990 3701 4413 2990 3701 4413 2990 3701 4413 3488 5278 3712 5617 4160 4365 4775 4887 SONES @ 0 IN. 1.7 2.9 4.2 2.2 3.2 4.9 2.7 4.1 5.6 3.6 4.1 6.1 3.8 5.4 7.3 4.0 5.5 7.6 4.0 5.4 7.6 5.4 7.6 9.6 7.1 12.1 8.1 14.1 9.9 10.4 11.7 13.6 MAX BHP .005 .009 .016 .007 .012 .022 .008 .015 .026 .011 .021 .035 .017 .033 .057 .019 .036 .062 .024 .045 .076 .037 .071 .120 .06 .22 .09 .30 .13 .17 .29 .32

in stock sizes include birdscreen, disconnect switch, UL/cUL 705 electrical. 0 138 170 203 187 231 276 254 314 374 296 367 438 335 415 495 399 494 588 520 644 768 717 888 1059 1015 1536 1222 1849 1581 1824 2348 2662 .125 73 125 166 110 178 232 179 257 327 200 294 377 249 348 439 307 421 529 420 564 700 569 780 969 893 1454 1078 1753 1452 1667 2184 2489 PRESSURE IN INCHES WG .25 .375 .5 .625 .75

120 91 176 171 274 195 310 134 272 379 179 340 464 292 478 633 389 640 863 747 1374 918 1659 1303 1498 2016 2319

96

190

214 175 314 233 393 373 558 493 745 568 1277 734 1560 1129 1313 1837 2135 1181 335 1453 889 1112 1629 1932 1341 381 794 1398 1697 1115 1411 1223 1086 974

238

308

169

472 184 623

338

474

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

ROOF MOUNTED FANS

Roof Exhaust Belt Drive - GB


Model GB centrifugal roof exhaust fans are belt drive. These fans are specifically designed for roof mounted applications exhausting relatively clean air. Fan wheels are centrifugal, backward-inclined, and constructed of aluminum. Adjustable motor pulleys allow for final system balancing.
B

PERFORMANCE
Performance capabilities range from 140 cfm to 44,690 cfm and up to 2.0 in. wg of static pressure.

C*

13/4 in.

GB CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL GB-071 GB-081 GB-091 GB-101 GB-121 GB-131 GB-141 GB-161 GB-180 GB-200 GB-220 GB-240 GB-260 GB-300 GB-330 GB-360 GB-420 GB-480 GB-500 GB-540 A 19 19 19 19 19 19 22 22 30 30 34 34 40 40 46 46 52 58 64 64 B
3

n Performance for available in stock sizes is shown on pages 8 & 9 1.75 2.0

C*

ROOF OPENING 1412 x 1412 1412 x 1412 1412 x 1412 1412 x 1412 1412 x 1412 1412 x 1412 1812 x 1812 1812 x 1812 2012 x 2012 2012 x 2012 2612 x 2612 2612 x 2612 3212 x 3212 3212 x 3212 3812 x 3812 3812 x 3812 4412 x 4412 5012 x 5012 5612 x 5612 5612 x 5612

24 8 2334 2438 2334 2438 2334 2438 2334 2438 2334 2838 2334 2838 2334 2838 2334 3512 3512 28 28

4234 3112 4234 3112 50 50 36 36

5834 3812 5834 3812 6514 44

7334 4714 83 83 5034 5034

PERFORMANCE IN INCHES WG DAMPER IN STOCK MIN/MAX SONES @ SIZE SIZES (n) RPM 0 IN. 0 .25 .5 .75 1 1.25 1.5 600 1.2 131 68 n 1710 11.1 372 334 292 245 198 600 2.2 301 175 n 1710 12.5 856 784 710 629 480 600 2.7 455 271 n 1710 13.4 1295 1179 1061 934 785 12 x 12 700 3.7 593 455 n 1800 13.2 1525 1418 1320 1208 1064 793 595 3.3 721 n 1725 17.4 2093 1984 1871 1743 1600 1426 595 4.5 844 655 n 1685 16.9 2391 2278 2157 2020 1857 1654 525 4.4 974 709 n 1705 20 3163 3020 2883 2739 2574 2370 16 x 16 478 4.7 1412 1030 n 1375 21 4062 3815 3571 3304 3007 2609 2073 495 4.3 1924 1150 n 1460 26 5677 5514 5335 5155 4938 4698 4426 18 x 18 440 6.5 2434 n 1200 24 6640 6336 5968 5650 5274 4828 4177 330 6.6 2507 985 23 7484 7212 6898 6568 6106 5547 4883 24 x 24 425 5.9 3902 3422 2691 n 910 24 8355 7916 7467 6932 6240 5388 3707 270 7.7 3487 835 23 10784 10292 9794 9225 8606 7932 7157 30 x 30 300 9.3 4859 3976 n 890 28 14416 13897 13335 12716 12072 11379 10536 255 5.2 6159 700 28 16908 16185 15408 14564 13624 12640 11538 36 x 36 215 4.8 5750 685 30 18321 17560 16711 15773 14710 13534 12119 180 2.5 7417 42 x 42 600 30 24724 23765 22709 21620 20103 18584 16590 150 5.6 9015 48 x 48 485 31 29148 27622 26016 24290 22106 19516 160 5.9 12893 460 33 37068 34991 32805 30342 27917 25310 54 x 54 160 6.3 14160 505 40 44694 43221 41157 38813 36503 33869 31293

4123 3077

3765

6024 9568 10184

4294 7963

26758

*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information refer to catalog Model G and GB, or contact your local representative.
6
ROOF MOUNTED FANS

Greenheck Fan Corporation certifies that the Model GB fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 E40001 - GB

Roof Exhaust Belt Drive - GB


SERVICE CHART
GB-071 through 200, 240 & 300 GB-220, 260, 330 and above High Pressure GB-101HP through 360HP

IN NEXT 3 STOCK DAY DAY


10 DAY

STANDARD CONSTRUCTION FEATURES


Aluminum housing Non-overloading backward-inclined wheel Galvanized birdscreen Integral reinforcing bead for strength Double-studded isolators for true vibration isolation Motor out of airstream Motor pulley is adjustable for system balancing NEMA-1 disconnect Lifting lugs (mid and larger sizes)

OPTIONS AND ACCESSORIES


Gravity and motorized dampers (In Stock) Galvanized roof curbs (In Stock) Aluminum roof curbs (See pages 38-39) Extended bases Insect screen bases Aluminum birdscreen Curb seal Hinged curb cap w/cable Curb adaptors Tie-down points Relubricatable bearings Dual drives UL/cUL 705 Electrical NEMA-3R and EXP disconnect switches High wind Greenheck coatings (See coatings page 119)

GB HIGH PRESSURE PERFORMANCE & DIMENSIONAL DATA


MODEL A B C* ROOF OPENING 1412 x 1412 DAMPER SIZE 12 x 12 MIN/MAX SONES @ RPM 0.25 IN. 1100 2550 700 16 x 16 GB-161HP 22 2838 2334 1812 x 1812 2170 700 1740 700 18 x 18 GB-200HP 30 3512 28 2012 x 2012 1700 700 1625 600 24 x 24 GB-240HP 34 4234 3112 2612 x 2612 1230 635 1240 30 x 30 460 1065 400 855 4.2 17.9 3.8 22 5.8 21 8.7 34 9.1 38 8.8 30 9.6 34 10.3 49 11.3 37 .25 365 1078 313 1659 821 2659 1639 4693 2311 6168 3197 7338 3639 7838 4096 4560 1695 5982 2489 7100 3035 7610 2912 7333 6858 5812 4414 2551 2442 1598 1536 1032 982 928 .5 .75 1

in stock sizes not available for High Pressure PERFORMANCE IN INCHES WG 1.5 2 2.5 2.75 3 3.25

GB-101HP

19

2438

2334

807

639

GB-141HP

22

2838

2334

1812 x 1812

1472

1328

1163

919

757

2325

2066

1714

987

GB-180HP

30

3512

28

2012 x 2012

4263

3964

3560

3037

2642

5642

5233

4767

4196

3859

3377

2725

GB-220HP

34

4234

3112

2612 x 2612

6611

6009

5263

4265

7053

6469

5775

4776

GB-300HP

40

50

36

3212 x 3212

11009 10688 10351 10006 9233 7118 5443

8429

7255

6543

GB-360HP

46

5834

3812

3812 x 3812

36 x 36

17382 16918 16236 15568 14315 12676 10368 8273

*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

ROOF MOUNTED FANS

GB Performance Data - In Stock


Stock model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.
MODEL GB-071-4X-QD-R2 873-1256 RPM 1/4 HP, 115/60/1 ODP GB-071-4X-QD-R3 1221-1710 RPM 1/4 HP, 115/60/1 ODP GB-081-4X-QD-R2 873-1256 RPM 1/4 HP, 115/60/1 ODP GB-081-4X-QD-R3 1221-1710 RPM 1/4 HP, 115/60/1 ODP GB-091-4X-QD-R2 863-1256 RPM 1/4 HP, 115/60/1 ODP GB-091-4X-QD-R3 1221-1710 RPM 1/4 HP, 115/60/1 ODP GB-101-4X-QD-R3 1056-1400 RPM 1/4 HP, 115/60/1 ODP GB-101-4X-QD-R4 1324-1688 RPM 1/4 HP, 115/60/1 ODP GB-101-LMDX-QD 588-1800 RPM
1

HP

RPM 600 939

TS 1757 2750 3652 4558 5009 1757 2750 3652 4558 5009 1757 2750 3652 4558 5009 2039 3393 4077 4761 5242 2035 2804 3574 4770 5300 5899 2044 2474 3299 4518 4948 5790 2010 2718 3522 4115 4479 5207 5915 6528

SONES @ 0 IN. 1.2 3.4 6.5 9.3 11.1 2.2 4.7 7.6 10.8 12.5 2.7 5.7 9.2 11.8 13.4 3.7 6.8 8.9 11.1 13.2 3.3 5.2 7.3 12.5 14.6 17.4 4.5 5.4 7.6 13.2 15.0 16.9 4.4 5.7 7.7 10.0 11.4 14.6 17.6 20

MAX BHP 0.006 0.021 0.05 0.098 0.13 0.008 0.031 0.073 0.14 0.19 0.011 0.042 0.098 0.19 0.25 0.020 0.091 0.16 0.25 0.33 0.021 0.054 0.111 0.25 0.33 0.50 0.024 0.043 0.103 0.26 0.35 0.56 0.030 0.074 0.16 0.26 0.34 0.53 0.78 1.03

PERFORMANCE IN INCHES WG 0 131 205 272 339 373 301 470 625 779 856 455 711 945 1179 1296 593 987 1186 1385 1525 722 995 1268 1692 1880 2093 844 1022 1362 1866 2044 2391 974 1317 1706 1994 2170 2522 2866 3163 .125 68 169 246 319 353 175 404 575 740 821 271 606 866 1116 1238 455 905 1117 1325 1471 542 877 1177 1625 1820 2038 655 879 1262 1794 1978 2335 709 1147 1576 1881 2066 2433 2787 3091 908 1439 1771 1966 2346 2709 3020 1258 1646 1858 2258 2634 2952 961 1489 1733 2166 2556 2883 1265 1574 2062 2475 2811 1355 1942 2384 2739 1602 2176 2574 650 1144 1718 1911 2279 990 1637 1838 2219 1545 1759 2158 1435 1674 2093 1305 1571 2020 1299 1857 728 1078 1557 1759 1984 962 1484 1696 1928 805 1404 1629 1871 1315 1555 1810 1214 1475 1743 907 1289 1600 830 1051 1269 1418 731 989 1214 1367 578 909 1161 1320 810 1094 1270 633 1019 1208 792 1064 490 785 1052 1180 263 698 988 1122 604 919 1062 454 848 999 772 934 504 785 330 525 700 785 470 660 748 403 615 710 284 571 669 517 630 511 127 217 296 335 185 274 312 154 248 292 109 223 269 197 246 120 198 .25 .375 .5 .625 .75 1

1247 1556 1710 600 939

1247 1556 1710 600 939

1247 1556 1710 700

1165 1400 1635

1800 595

GB-121-4X-QD 980-1395 RPM 1/4 HP, 115/60/1 ODP GB-121-LMDX-QD 595-1550 RPM

820 1045 1395

3 2

1550 1725 595

GB-131-4X-QD 942-1315 RPM 1/4 HP, 115/60/1 ODP GB-131-5X-QD 1299-1685 RPM 1/2 HP, 115/208-230/60/1 ODP GB-131-LMDX-QD 540-1685 RPM GB-141-4X-QD 614-865 RPM 1/4 HP, 115/60/1 ODP GB-141-3X-QD 906-1170 RPM 1/3 HP, 115/60/1 ODP GB-141-5X-QD 1049-1360 RPM 1/2 HP 115/208-230/60/1 ODP GB-141-LMDX-QD 450-1545 RPM
1

720 960 1315

3 2

1440 1685 525

710 920 1075

3 2 4

1170 1360 1545 1705

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

ROOF MOUNTED FANS

GB Performance Data - In Stock


Stock model GB fans include galvanized birdscreen, disconnect switch, UL/cUL 705 Electrical.
MODEL HP RPM 478 GB-161-5X-QD 852-1100 RPM 1/2 HP 115/208-230/60/1 ODP GB-161-LMDX-QD 425-1375 RPM 1/4 625 865
1

TS 2080 2720 3764 4113 4787 5440 5984 2397 3535 3923 4552 5109 5739 6465 7071 2462 3357 3721 4308 4812 5400 6099 6715 2726 2950 3239 3752 4233 4682 5291 5836 2395 2914 3353 3792 4231 4790 5309 6068 7106

SONES @ 0 IN. 4.7 6.4 10.6 12.6 15.3 17.9 21 4.3 7.4 8.8 12.7 16.2 19.0 22 26 6.5 8.5 9.6 12.1 14.1 16.7 20 24 5.9 6.7 7.8 10.3 13.1 15.8 19.7 24 9.3 9.2 9.6 11.4 13.4 15.9 18.8 23 28

MAX BHP 0.044 0.097 0.26 0.34 0.53 0.79 1.05 0.078 0.26 0.35 0.55 0.77 1.1 1.54 1.97 0.103 0.26 0.35 0.55 0.77 1.09 1.57 2.09 0.21 0.26 0.35 0.55 0.79 1.06 1.54 2.06 0.19 0.35 0.53 0.77 1.07 1.55 2.12 3.15 5.05

PERFORMANCE IN INCHES WG 0 1412 1846 2555 2791 3249 3692 4062 1924 2838 3149 3655 4102 4607 5191 5677 2434 3320 3679 4260 4759 5340 6031 6640 3902 4223 4636 5371 6059 6702 7574 8355 4859 5912 6803 7694 8584 9718 10771 12310 14416 .125 1030 1574 2359 2612 3094 3556 3938 1645 2667 2997 3526 3989 4507 5102 5595 1975 2984 3378 4013 4548 5157 5870 6493 3422 3784 4241 5030 5756 6427 7331 8134 3976 5222 6221 7197 8149 9334 10424 12007 14157 4339 5536 6615 7639 8906 10059 11703 13897 4640 5954 7094 8445 9648 11357 13638 5094 6455 7951 9228 10996 13335 5667 7387 8772 10629 13027 4194 6721 8268 10241 12716 7025 9369 12072 10536 7963 2637 3084 3744 4289 4927 5681 6336 2691 3188 3760 4665 5449 6157 7091 7916 2036 3059 4194 5093 5861 6844 7699 3562 4636 5506 6573 7467 2112 4073 5076 6261 7214 3217 4567 5901 6932 5002 6240 3707 2088 2705 3477 4068 4719 5473 6144 2087 3140 3810 4519 5301 5968 2643 3504 4285 5123 5812 3085 4015 4924 5650 3239 4449 5274 4177 1221 2162 2433 2943 3421 3815 1150 2469 2832 3387 3866 4400 5010 5514 2212 2623 3234 3741 4290 4912 5424 1882 2375 3052 3596 4179 4814 5335 2052 2843 3432 4045 4715 5245 2600 3251 3900 4599 5155 2811 3575 4343 4938 4426 3765 1932 2236 2786 3288 3694 1624 2009 2614 3149 3571 1692 2428 2997 3444 2197 2838 3304 2443 3007 2073 .25 .375 .5 .625 .75 1 1.5 2

3 2 4

945 1100 1250 1375 495 730 810 940 1055 1185 1335 1460 440 600 665 770 860 965 1090 1200 425 460 505 585 660 730 825 910 300 365 420 475 530 600 665 760 890

1
1

GB-180-5X-QD 676-940 RPM 1/2 HP 115/208-230/60/1 ODP GB-180-LMDX-QD 495-1460 RPM

3 2 4

1 112 2
1

3 2 4

GB-200-LMDX-QD 440-1200 RPM

1 112 2
1

3 2 4

GB-240-LMDX-QD 300-910 RPM

1 112 2
1

3 2 4

GB-300-LMDX-QD 250-890 RPM

1 112 2 3 5

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

ROOF MOUNTED FANS

Low Silhouette Roof Exhaust - LD/LDP


Models LD and LB are available in Fabra Style hoods and Models LDP and LBP are available in louvered penthouse hoods. These fans offer attractive appearance combined with rugged construction, high performance, and low sound level. Fan wheels shall be centrifugal, backward-inclined and constructed of aluminum. Model LD and LDP Roof Exhaust fans are centrifugal direct drive. Model LB and LBP roof exhaust fans are centrifugal belt drive. Adjustable motor pulleys allow for final system balancing.
MODEL LD
B 1.75 in. A MODEL LDP C B D

A 1.75 in. A C D D 1.75 in. A A B

PERFORMANCE
SERVICE CHART
LD/LDP/LB/LBP - All models & sizes 10 DAY
Models LD and LDP performance capabilities range from 79 cfm to 1,848 cfm and up to 0.75 in. wg of static pressure. Model LB and LBP performance capabilities range from 351cfm to 37,000 cfm and up to 1.25 in. wg of static pressure.

LD/LDP DIRECT DRIVE CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL LD/LDP-60 LD/LDP-65 LD/LDP-70 LD/LDP-75 LD/LDP-80 LD/LDP-85 LD/LDP-90 LD/LDP-95 LD/LDP-100 A sq. 17 17 17 17 19 19 19 19 22 B LD LDP LD 22 22 22 22 28 28 28 28 30 23 23 23 23 25 25 25 25 28 27 27 27 27 27 27 27 27 27 C LDP 23 23 23 23 25 25 25 25 28 D LD LDP 13 13 13 13 16 16 16 16 18 1312 1312 13 2
1

ROOF OPENING 1012 x 1012 1012 x 1012 1012 x 1012 1012 x 1012 12 2 x 12 2
1 1

DAMPER SIZE

MIN/MAX SONES @ RPM 0 IN. 1590 4.8 5.6 6.4 5.8 8.8 8.6 8.8 11.8 6.3 16.2 6.6 21

PERFORMANCE IN INCHES WG 0 202 274 360 400 481 576 819 1052 767 .125 164 238 314 351 413 490 714 942 568 891 .25 119 187 257 290 342 403 608 825 129 188 222 258 291 485 695 361 552 396 .375 .5 .625 .75

8x8

1680 1665 1620 1550

1312 16 2
1

1612 1612 16 2
1

1212 x 1212 1212 x 1212 12 2 x 12 2


1 1

10 x 10

1500 1550 1550 860

1812

1412 x 1412 12 x 12

1725 860 1725

1538 1458 1361 1256 1142 1024 921 703

LD/LDP-120

22

30

28

27

28

18

1812

1412 x 1412

1848 1762 1652 1540 1412 1286 1143

All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information refer to catalog Model LD/LDP & LB/LBP, or contact your local representative.

Greenheck Fan Corporation certifies that the Models LD, LDP, LB and LBP shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 MH11745 LD, LB, LDP & LBP

10

ROOF MOUNTED FANS

Low Silhouette Roof Exhaust - LB/LBP


STANDARD CONSTRUCTION FEATURES
Aluminum housing with hinged hood Non-overloading backward-inclined aluminum wheel Curb cap with prepunched mounting holes Motor and drives isolated on shock mounts Birdscreen mounted to the discharge perimeter Ball bearing motors Adjustable motor pulley Adjustable motor plate Fan shaft mounted in ball bearing pillow blocks Static free belts Corrosion-resistant fasteners NEMA-1 disconnect
B D 1.75 in.

OPTIONS AND ACCESSORIES


Galvanized housing Performance baffle (Direct drive models) Gravity and motorized dampers Galvanized and aluminum roof curbs (See pages 38-39) Curb seal Curb adaptors Aluminum birdscreen Speed control (Direct drive models) Relubricatable bearings UL/cUL 705 Electrical Dual Drives NEMA-3R and EXP disconnect switches Greenheck coatings (See coatings page 119)
B

MODEL LBP

A C

MODEL LB
A C

1.75 in.

LB BELT DRIVE CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL A B C 39 39 39 51 D 17 18 21 23 E 314 4 412 6 ROOF OPENING 1412 x 1412 1812 x 1812 2012 x 2012 2012 x 2012 2612 x 2612 3212 x 3212 3812 x 3812 4412 x 4412 5012 x 5012 5612 x 5612 LB-10 22 x 22 28 LB-14 26 x 26 35 LB-18 30 x 30 40 LB-21 30 x 30 43 DAMPER MIN/MAX SONES SIZE RPM @ 0 IN. 600 3.0 12 x 12 1767 13.5 480 4.1 16 x 16 1343 14.4 465 3.6 1460 26 18 x 18 465 6.6 1200 26 355 5.8 24 x 24 910 27 230 8.0 30 x 30 835 27 220 4.9 36 x 36 678 30 190 5.2 42 x 42 515 25 150 6.1 48 x 48 420 23 130 4.6 54 x 54 401 25 PERFORMANCE IN INCHES WG 0 .125 .25 .5 .75 1 539 351 1587 1533 1480 1385 1254 1112 903 614 2525 2456 2372 2199 1979 1692 1753 1422 5505 5417 5328 5138 4936 4714 2820 2420 1732 7278 7156 7034 6712 6375 5954 3419 2806 8763 8549 8333 7889 7377 6713 3910 2576 14194 13914 13635 13062 12432 11728 6204 4803 19121 18770 18419 17621 16683 15636 8328 6455 22574 22037 21500 20214 18651 16871 9666 6546 27065 26278 25383 23363 21159 18029 12159 37506 36544 35583 33500 30332 26018

LB-24 34 x 34 4512 51 2312 634 LB-30 40 x 40 50 LB-36 46 x 46 60 63 2658 812 63 3258 934

LB-42 52 x 52 7058 75 3738 1112 LB-48 58 x 58 7058 87 4112 1158 LB-54 64 x 64 7912 87 4538 1212

LBP BELT DRIVE CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL A B 28 32 36 36 40 46 5134 58 64 70 C 3812 40 46 46 D 17 17 2412 2412 LBP-10 22 x 2258 LBP-14 26 x 26 LBP-18 30 x 30 LBP-21 30 x 30 LBP-24 34 x 34 LBP-30 40 x 40 LBP-36 46 x 46 LBP-42 52 x 52 LBP-48 58 x 58 LBP-54 64 x 64 PERFORMANCE IN INCHES WG ROOF DAMPER MIN/MAX SONES @ OPENING SIZE RPM 0 IN. 0 .125 .25 .5 .75 1 600 3.0 539 351 1412 x 1412 12 x 12 1767 13.5 1587 1533 1480 1385 1254 1112 480 4.1 903 614 1812 x 1812 16 x 16 1343 14.4 2525 2456 2372 2199 1979 1692 465 3.6 1753 1422 2012 x 2012 1460 26 5505 5417 5328 5138 4936 4714 18 x 18 465 6.6 2820 2420 1732 2012 x 2012 1200 26 7278 7156 7034 6712 6375 5954 355 5.8 3419 2806 2612 x 2612 24 x 24 910 27 8763 8549 8333 7889 7377 6713 230 8.0 3910 2576 3212 x 3212 30 x 30 835 27 14194 13914 13635 13062 12432 11728 220 4.9 6204 4803 3812 x 3812 36 x 36 678 30 19121 18770 18419 17621 16683 15636 190 5.2 8328 6455 4412 x 4412 42 x 42 515 25 22574 22037 21500 20214 18651 16871 150 6.1 9666 6546 5012 x 5012 48 x 48 420 23 27065 26278 25383 23363 21159 18029 130 4.6 12159 5612 x 5612 54 x 54 401 25 37506 36544 35583 33500 30332 26018

All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of a birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

4912 2312 58 63 2612 3438

7012 3814 7612 4038 8312 4358

ROOF MOUNTED FANS

11

Upblast Roof Exhaust Direct Drive - CUE/CUE-HP


Model CUE centrifugal roof exhaust fans are direct drive. These fans are specifically designed for roof mounted applications. Exhaust air is discharged directly upward, away from the roof surface. Fan wheels are centrifugal, backward-inclined and constructed of aluminum.

PERFORMANCE
Performance capabilities range from 130 cfm to 6,410 cfm and up to 1.5 in. wg of static pressure.
"
D C*

1 3/4 in. A

CUE CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA n Performance for available in stock sizes is shown on page 13
MODEL A B 1838 1838 1838 1838 21 21 21 21 2478 2478 2478 2478 2878 2878 2338 2338 C* 1312 1312 1312 1312 1338 1338 1338 1514 2814 2814 2814 2814 2934 2934 2858 2858 D 1138 1138 1138 1138 1112 1112 1112 13716 1738 1738 1738 1738 1938 1938 21 21 ROOF OPENING 1012 x 1012 1012 x 1012 1012 x 1012 1012 x 1012 1212 x 1212 1212 x 1212 1212 x 1212 1212 x 1212 1412 x 1412 1412 x 1412 1412 x 1412 1412 x 1412 1812 x 1812 1812 x 1812 2012 x 2012 2012 x 2012 CUE-060 17 CUE-065 17 CUE-070 17 CUE-075 17 CUE-080 19 CUE-085 19 CUE-090 19 CUE-095 19 CUE-098 19 CUE-101 19 CUE-121 19 CUE-131 19 CUE-141 22 CUE-161 22 CUE-180 30 CUE-200 30 PERFORMANCE IN INCHES WG DAMPER IN STOCK MIN/MAX SONES @ SIZE ^ SIZES (n) RPM 0 IN. 0 .125 .25 .5 .75 1.5 1050 1.7 133 81 1550 4.2 197 164 128 1050 2.2 180 109 1550 4.7 266 222 172 8x8 1050 2.6 250 171 1550 5.5 369 325 269 1050 3.4 287 188 1550 6.0 424 359 291 1050 3.8 325 247 133 1550 7.3 480 431 376 235 1050 4.0 389 305 182 1550 7.5 574 520 461 312 10 x 10 1050 4.1 549 451 306 1550 7.8 811 744 677 501 1050 5.3 711 570 381 1550 9.6 1049 964 861 616 860 8.4 588 409 1725 13.8 1180 1094 1017 824 586 860 4.6 732 625 481 n 1725 13.3 1468 1422 1373 1255 1129 12 x 12 860 5.3 1015 905 781 n 1725 15.6 2037 1979 1923 1816 1710 1176 860 8.5 1180 1057 914 1725 18.8 2366 2305 2244 2122 1994 860 7.3 1558 1427 1264 1725 26 3125 3066 3005 2865 2711 2085 16 x 16 860 10.7 2472 2315 2126 1680 1725 30 4959 4882 4806 4646 4463 3855 860 12.3 3249 3074 2922 2474 1140 17.6 4307 4173 4045 3822 3470 18 x 18 860 15.7 4837 4587 4346 3815 3084 1140 24 6412 6224 6036 5674 5283 3445

*May be greater depending on motor. All dimensions in inches. ^Dampers should not be used in grease applications. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information refer to catalog Series C, or contact your local representative.

Greenheck Fan Corporation certifies that the Model CUE fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 UL/cUL 762 (size 98 and up) E40001 - CUE

12

ROOF MOUNTED FANS

Upblast Roof Exhaust Direct Drive - CUE/CUE-HP


SERVICE CHART
CUE-101 and 121 All Models and Sizes

IN NEXT STOCK DAY


3 DAY

10 DAY

OPTIONS AND ACCESSORIES


Galvanized or aluminum birdscreen Gravity and motorized dampers (In Stock) Galvanized roof curbs (In Stock) Aluminum roof curbs (See pages 38-39) UL/cUL 705 Electrical UL/cUL 762 Grease (Size 098 and up) Grease trap with drain connection Drain connection Hinged curb cap kit w/cable (In stock) Curb seal Curb adaptors Tie-down points Windband extension Speed controls NEMA-3R and EXP disconnect switches High wind Greenheck coatings (See coatings page 119)

STANDARD CONSTRUCTION FEATURES


Aluminum housing Non-overloading backward-inclined aluminum wheel Aluminum curb cap with prepunched mounting holes Drain trough Ball bearing motors (sizes 098-161), sleeve bearing motors (sizes 060-095) Motor isolated on shock mounts Corrosion-resistant fasteners NEMA-1 disconnect

CUE HIGH PRESSURE CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL A B 2278 2878 2338 C* 2434 2434 2558 D 1938 1938 21 ROOF OPENING 1812 x 1812 1812 x 1812 2012 x 2012 DAMPER MIN/MAX SONES SIZE^ RPM @ 0.5 IN. 16 x 16 16 x 16 18 x 18 1725 1140 1725 1725 16.1 12.5 22 28 PERFORMANCE IN INCHES WG .5 1256 1645 2787 4613 .75 1178 1444 2680 4493 1 1098 1175 2560 4353 2439 4215 2310 4078 2167 2003 3740 1.25 999 1.5 879 1.75 747 2

CUE-141HP 22 CUE-161HP 22 CUE-180HP 30

*May be greater depending on motor. All dimensions in inches. ^Dampers should not be used in grease applications. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

CUE PERFORMANCE DATA - IN STOCK


MODEL CUE-101-AX-QD 1/4 HP CUE-121-AX-QD 1/2 HP MOTOR SPEED CODE A A RPM TS SONES @ 0 IN. 13.3 15.6 MAX BHP 0.29 0.47 0 1468 2037

in stock sizes include disconnect switch, UL/cUL 705 electrical. PERFORMANCE IN INCHES WG .125 1422 1979 .25 1372 1923 .375 1314 1869 .5 1254 1816 .625 1194 1763 .75 1129 1710 1 969 1571

1725 1725

5024 5899

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include drive losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

ROOF MOUNTED FANS

13

Upblast Roof Exhaust Belt Drive - CUBE


Model CUBE centrifugal roof exhaust fans are belt drive. These fans are specifically designed for roof mounted applications. Exhaust air is discharged directly upward, away from the roof surface. Fan wheels are centrifugal, backward-inclined, and constructed of aluminum. Adjustable motor pulleys allow for final system balancing.

PERFORMANCE
C*

Performance capabilities range from 258 cfm to 30,000 cfm and up to 5 in. wg of static pressure.

13/4 in.

CUBE CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA n Performance for available in stock sizes is shown on pages 16 & 17
MODEL A B C* D CUBE-098 19 CUBE-101 19 CUBE-121 19 CUBE-131 19 CUBE-141 22 CUBE-161 22 CUBE-180 30 CUBE-200 30 CUBE-220 34 CUBE-240 34 CUBE-300 40 CUBE-360 46 CUBE-420 52 2478 2814 1738 2478 2814 1738 2478 2814 1738 2478 2814 1738 2878 2934 1938 2878 2934 1938 3538 2858 3538 2858 21 21 ROOF DAMPER IN STOCK MIN/MAX SONES OPENING SIZE^ SIZES (n) RPM @ 0 IN. 650 8.1 1 1 14 2 x 14 2 n 1725 13.8 860 4.6 1412 x 1412 n 1820 14.3 12 x 12 685 4.4 1412 x 1412 n 1725 15.6 650 6.2 1412 x 1412 1645 17.9 590 5.0 1812 x 1812 n 1725 26 16 x 16 730 8.1 1812 x 1812 n 1390 22 630 7.1 1 1 20 2 x 20 2 n 1495 28 18 x 18 500 6.2 1 1 20 2 x 20 2 n 1210 25 450 7.3 2612 x 2612 955 25 24 x 24 410 6.4 1 1 26 2 x 26 2 n 930 24 355 6.9 1 1 32 2 x 32 2 30 x 30 n 905 32 300 6.9 3812 x 3812 36 x 36 690 30 220 6.5 1 1 44 2 x 44 2 42 x 42 600 29 180 5.5 1 1 50 2 x 50 2 48 x 48 490 28 PERFORMANCE IN INCHES WG 0 .25 .5 .75 1 2 445 1180 1017 824 586 732 625 481 1549 1459 1350 1234 1106 809 2037 1923 1816 1710 1571 892 2256 2128 2001 1864 1684 1069 3125 3005 2865 2711 2539 2098 1669 3996 3806 3584 3340 3078 2380 1861 5648 5443 5254 5082 4921 3564 2812 1822 6806 6451 6108 5748 5350 3585 2624 7607 7202 6799 6347 5844 3717 2471 8431 7985 7536 6953 6375 5777 4227 14727 14266 13788 13223 12614 9178 8092 6023 18611 17884 17115 16236 15243 9353 5075 25508 24604 23451 22295 21023 11016 29988 28697 27291 25704 23674

4234 3378 2512 4234 3378 2512 50 36 29

5658 3918 2938 6538 4434 3514 36

CUBE-480 58 74316 4818

*May be greater depending on motor. All dimensions in inches. ^Dampers should not be used in grease applications. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information refer to catalog Series C, or contact your local representative.

Greenheck Fan Corporation certifies that the Model CUBE fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 UL/cUL 762 MH 11745-CUBE

14

ROOF MOUNTED FANS

Upblast Roof Exhaust Belt Drive - CUBE


SERVICE CHART
CUBE-098 through 121, 141 through 240 & 300 CUBE-098 through 480 High Pressure CUBE-141HP through 180HP & 240HP High Pressure CUBE-101HP through 360HP Extended Pressure CUBE-161xP through 360xP

IN NEXT 3 STOCK DAY DAY


10 DAY

STANDARD CONSTRUCTION FEATURES


Aluminum housing Non-overloading backward-inclined aluminum wheel Curb cap with prepunched mounting holes Motor and drives isolated on shock mounts Drain trough Ball bearing motors Adjustable motor pulley Adjustable motor plate Fan shaft mounted in ball bearings Static-resistant belts Corrosion-resistant fasteners NEMA-1 disconnect

OPTIONS AND ACCESSORIES


Galvanized birdscreen (In stock) Aluminum birdscreen Gravity and motorized dampers for non-UL/cUL 762 applications (In Stock) Galvanized roof curbs (In stock) Aluminum roof curbs (See pages 38-39) Vented curb extensions (See pages 38-39) Heat baffles UL/cUL 705 Electrical UL/cUL 762 Grease Nonstick wheels Clean out port Drain connection Grease trap w/drain connection Hinged curb cap kit w/cable (In stock) Curb seal Curb adaptors Windband extension Tie-down points Relubricatable bearings Dual drives NEMA-3R and EXP disconnect switches High wind Greenheck coatings (See coatings page 119)

CUBE HIGH PRESSURE CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA n Performance for available in stock sizes is shown on page 17
MODEL A B 2478 2878 2878 3538 3538 4234 4234 50 5858 C* D CUBE-101HP 19 CUBE-141HP 22 CUBE-161HP 22 CUBE-180HP 30 CUBE-200HP 30 CUBE-220HP 34 CUBE-240HP 34 CUBE-300HP 40 CUBE-360HP 46 2814 1738 2934 1938 2934 1938 2858 2858 21 21 IN PERFORMANCE ROOF DAMPER MIN/MAX SONES STOCK OPENING SIZE^ SIZES (n) RPM @ 0.5 IN. .5 .75 1.25 1300 6.0 335 1412 x 1412 12 x 12 2580 16.8 1014 969 861 895 6.1 331 1812 x 1812 n 2110 19.8 1592 1536 1409 16 x 16 825 7.0 889 1812 x 1812 1690 21 2722 2611 2365 795 8.3 1570 2012 x 2012 n 1685 27 4495 4369 4085 18 x 18 740 8.1 2024 2012 x 2012 1600 29 5943 5775 5385 650 8.6 2909 1940 1 1 26 2 x 26 2 1240 26 6895 6684 6217 24 x 24 635 8.1 3046 2612 x 2612 n 1230 26 7513 7280 6730 460 7.3 3125 1 1 32 2 x 32 2 30 x 30 1045 35 10909 10570 9855 420 9.6 6407 3812 x 3812 36 x 36 865 33 17129 16631 15544 IN INCHES WG 1.75 735 1262 2082 3768 4971 5637 6090 9054 2.25 550 1073 1664 3325 4476 4885 5326 8002 6463 2766 3760 3633 804 2.75

3378 2512 3378 2512 36 29

3918 2938

14315 12738 10197

CUBE ExTENDED PRESSURE CONDENSED PERFORMANCE RANGES in stock sizes not available for extended Pressure & DIMENSIONAL DATA
MODEL A B 2878 42 4
3

C* 2934 33 8
7

D 1938 25 2
1

ROOF OPENING 1812 x 1812 26 2 x 26 2


1 1

DAMPER SIZE ^ 16 x 16 24 x 24 30 x 30 36 x 36

MIN/MAX SONES @ RPM 0 IN. 1550 2525 1100 2165 790 1690 700 1490 10.0 22 10.9 29 9.4 36 10.5 33

PERFORMANCE IN INCHES WG 1 968 2339 1292 3927 1776 7643 3210 10699 10294 9871 8907 7673 5830 7284 6920 6091 4951 3733 3535 3063 2461 1324 2155 1946 1221 1.5 2 3 4 5

CUBE-161XP 22 CUBE-240XP 34 CUBE-300XP 40 CUBE-360XP 46

50 5858

36 3918

29 2938

32 2 x 32 2
1 1

3812 x 3812

*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap. ^Dampers should not be used in grease applications. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

ROOF MOUNTED FANS

15

CUBE Performance Data - In Stock


Stock model CUBE fans include disconnect switch, UL/cUL 762 label and heat baffle.
MODEL CUBE-098-4G-QD 1259-1725 RPM 1/4 HP, 115/60/1 ODP CUBE-101-4G-QD 1191-1660 RPM 1/4 HP, 115/60/1 ODP CUBE-101-3G-QD 1408-1820 RPM 1/3 HP, 115/208-230/60/1 ODP CUBE-101-LMDG-QD 960-1820 RPM CUBE-121-3G-QD 1068-1545 RPM 1/3 HP, 115/230/60/1 ODP CUBE-121-LMDG-QD 685-1545 RPM CUBE-141-5G-QD 951-1400 RPM 1/2 HP, 115/208-230/60/1 ODP CUBE-141-7G-QD 1215-1595 RPM 3/4 HP, 115/208-230/60/1 ODP CUBE-141-LMDG-QD 590-1595 RPM CUBE-161-7G-QD 935-1265 RPM 3/4 HP, 115/208-230/60/1 ODP CUBE-161-LMDG-QD 730-1390 RPM
1

HP

RPM 1160

TS 3302 3786 4412 2505 3509 4834 5300 2342 2889 3573 4821 5283 2259 4230 4632 5322 6106 3177 3808 4200 4831 5505 6049 3051 3608 3971 4552 5206 5739 6586 7240 2797 3385 3721 4252 4896 5372 6155 6771

SONES @ 0 IN. 9.2 10.7 13.0 4.6 7.7 12.7 14.3 4.4 5.3 6.5 11.1 12.8 5.0 10.9 12.2 14.9 20 8.1 11.0 12.4 15.0 18.5 22 7.1 9.2 11.2 13.8 16.5 18.5 23 28 6.2 8.1 9.4 12.1 16.3 18.7 23 25

MAX BHP 0.006 0.09 0.14 0.04 0.100 0.26 0.35 0.029 0.056 0.105 0.26 0.34 0.040 0.26 0.34 0.52 0.79 0.15 0.26 0.35 0.54 0.79 1.05 0.16 0.26 0.34 0.52 0.78 1.04 1.58 2.10 0.15 0.26 0.35 0.52 0.79 1.04 1.57 2.09

PERFORMANCE IN INCHES WG 0 793 909 1060 732 1025 1413 1549 808 997 1233 1664 1824 1068 2001 2191 2517 2889 2098 2515 2774 3190 3636 3995 2380 2814 3097 3551 4061 4476 5137 5647 2812 3402 3740 4274 4921 5399 6187 6805 .125 672 804 966 625 957 1364 1505 669 885 1141 1594 1760 851 1905 2106 2445 2825 1904 2361 2637 3072 3532 3900 2154 2616 2915 3388 3919 4347 5025 5545 2386 3054 3421 3993 4676 5175 5991 6628 1792 2006 2361 2757 1669 2177 2476 2940 3425 3806 1861 2448 2759 3243 3786 4223 4913 5443 1821 2674 3095 3718 4438 4957 5798 6450 2144 2699 3413 4192 4742 5610 6279 2072 3048 3922 4508 5420 6108 2517 3626 4253 5216 5932 3240 3985 5006 5747 3168 4528 5349 1667 1896 2271 2683 1389 1974 2300 2796 3301 3698 1403 2143 2525 3115 3666 4108 4811 5345 1763 2257 2879 3554 4005 4710 5253 1866 2654 3344 3903 4620 5162 2363 3141 3702 4531 5082 2652 3336 4232 4921 1743 2109 2640 3172 3584 1364 1893 2475 3035 3464 1583 2297 2893 3340 1770 2582 3078 1515 1772 2173 2601 1318 1628 2068 2517 998 1442 1949 2429 1642 2225 757 1053 1528 1698 944 1463 1639 798 1398 1580 1315 1518 1224 1441 965 1262 .25 522 689 878 481 873 1313 1458 782 1251 1406 662 1189 1350 1125 1293 1056 1234 861 1106 361 644 502 .375 .5 .625 .75 1

1330 1550 860

1205 1660

1820 685

845 1045 1410

1545 590

4 1105

3 2

1210 1390 1595 730 875 965 1110 1265 1390 630 745 820 940 1075 1185 1360 1495 500 605 665 760 875 960 1100 1210

3/4
1

4 3 2 4

1 1 3

1
1

4 3 2 4

1 1 3

CUBE-180-LMDG-QD 630-1495 RPM

1 1 2
1

2
1

4 3 2 4

1 1 3

CUBE-200-LMDG-QD 500-1210 RPM

1 1 2
1

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

16

ROOF MOUNTED FANS

CUBE Performance Data - In Stock


Stock model CUBE fans include disconnect switch, UL/cUL 762 label and heat baffle.
MODEL HP
1

RPM 410 465 510 585 670 735 845 930 355 365 420 480 530 605 665 765 905

TS 2629 2982 3271 3752 4297 4714 5419 5965 2834 2914 3353 3832 4231 4830 5309 6108 7226

SONES @ 0 IN. 6.4 7.6 8.9 11.5 14.3 16.6 19.6 24 6.9 7.2 9.0 11.0 13.3 17.0 20 24 32

MAX BHP 0.18 0.26 0.34 0.51 0.79 1.04 1.58 2.10 0.31 0.34 0.52 0.77 1.05 1.56 2.07 3.15 5.19

0 3716 4215 4623 5303 6073 6663 7660 8431 5777 5939 6834 7811 8624 9845 10821 12449 14727

.125 3169 3767 4242 4960 5762 6370 7399 8194 5131 5316 6314 7376 8231 9500 10508 12176 14496

PERFORMANCE IN INCHES WG .25 .375 .5 .625 2471 3187 3716 4539 5460 6133 7183 7985 4226 4463 5659 6844 7771 9127 10192 11903 14266 4820 6231 7245 8705 9410 11607 14036 5440 6636 8226 8967 11273 13788 5879 7707 8495 10938 13505 2162 3134 4093 5052 5764 6947 7798 3565 4059 5409 6615 7536 4202 5037 6304 7233

.75

4 3 2 4

CUBE-240-LMDG-QD 410-930 RPM

1 3

3524 4618 6002 6953 5282 6375

1 112 2
1

3 2 4

1 3

CUBE-300-LMDG-QD 355-905 RPM

1 112 2 3 5

7083 7270 10553 13203 9743 12614

CUBE-HP Performance Data - In Stock


Stock Model CUBE-HP fans include disconnect switch, UL/cUL 762 label and heat baffle.
MODEL HP RPM 895
1

TS 3426 5609 6145 7064 8078 3850 4480 5158 5884 6465 7410 8160 4329 4970 5451 6253 6863 7889

SONES @ 0.5 IN. 6.1 14.2 15.2 17.0 19.8 8.3 10.8 13.8 15.0 18.7 24 27 9.4 13.1 14.5 18.4 22 26

MAX BHP 0.055 0.26 0.34 0.52 0.78 0.22 0.35 0.53 0.79 1.04 1.57 2.09 0.52 0.78 1.04 1.56 2.08 3.16

PERFORMANCE IN INCHES WG .5 330 1015 1146 1363 1592 1570 2104 2581 3062 3440 4034 4495 3405 4232 4811 5736 6404 7513 1687 2323 2867 3260 3884 4369 2606 3704 4367 5386 6112 7279 2940 3845 4988 5774 7016 3024 4538 5407 6729 4005 4990 6409 4549 6090 3624 5709 5325 4721 1932 2626 3075 3728 4225 2286 2839 3574 4085 1853 2523 3375 3945 2155 3134 3767 2859 3574 2533 3324 3061 920 1062 1292 1535 797 965 1218 1472 642 845 1136 1408 703 1041 1341 923 1261 800 1178 1073 965 .75 1 1.25 1.5 1.75 2 2.25 2.5

4 1465

CUBE-141HP-LMDG-QD 895-2110 RPM

3 2 4 4 3 2 4

1605 1845 2110 795 925 1065 1215 1335 1530 1685 675 775 850 975 1070 1230

CUBE-180HP-LMDG-QD 795-1685 RPM

1 112 2
1

2 4

CUBE-240HP-LMDG-QD 635-1230 RPM

1 112 2 3

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

ROOF MOUNTED FANS

17

Ultimate Steel Grease Fan - USGF


Model USGF is specifically designed for severe grease exhaust applications and to discharge air directly away from the mounting surface. It is the only spun steel fan in the industry. Meets Miami-Dade protocol for Large Missile Impact Test.

PERFORMANCE
Performance capabilities up to 7,000 cfm and up to 3 in. wg of static pressure.

C*

SERVICE CHART
13/4 in.

10 DAY

USGF

STANDARD CONSTRUCTION FEATURES


Steel housing UL/cUL 762 Grease Non-overloading backwardinclined nonstick steel wheel NEMA-3R disconnect switches Coated with Permatector finish Heat baffle Clean out port Hinged curb cap kit w/cables Dual drives Steel curb cap with prepunched mounting holes
MODEL USGF-140 USGF-160 USGF-180 USGF-200 A 26 26 30 30 B 2878 2878 3538 35 8
3

Motor and drives isolated on shock mounts Drain trough Ball bearing motors Relubricatable Bearings Adjustable motor pulley Adjustable motor plate Fan shaft mounted in ball bearings Static-resistant belts Corrosion-resistant fasteners

OPTIONS AND ACCESSORIES


Galvanized roof curbs (In stock) Vented curb extensions Drain connection Grease trap w/drain connection Curb seal Curb adaptors Windband extension Greenheck coatings (See coatings page 19) 1

USGF STANDARD PERFORMANCE RANGES & DIMENSIONAL DATA


C* 2934 2934 2858 28 8
5

D 1938 1938 21 21

ROOF OPENING 1812 x 1812 1812 x 1812 2012 x 2012 20 2 x 20 2


1 1

MIN/MAX SONES @ RPM 0 IN. 590 5.0 1725 26 730 8.1 1390 22 630 7.1 1495 28 500 6.2 1210 25

0 1069 3125 2098 3996 2380 5648 2812 6806

PERFORMANCE IN INCHES WG .25 .5 .75 1 3005 1669 3806 1861 5443 1822 6451 2865 3584 5254 6108 2711 3340 5082 5748 2539 3078 4921 5350

3564

HIGH PRESSURE PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL USGF-140HP USGF-160HP USGF-180HP USGF-200HP A 26 26 30 30 B 2878 2878 35 8
3

C* 2934 2934 28 8
5

D 1938 1938 21 21

ROOF OPENING 1812 x 1812 1812 x 1812 20 2 x 20 2


1 1

35 8
3

28 8
5

2012 x 2012

MIN/MAX SONES @ RPM 0.5 IN. 895 6.1 2110 19.8 825 7.0 1690 21 795 8.3 1685 27 740 8.1 1600 29

.5 331 1592 889 2722 1570 4495 2024 5943

PERFORMANCE IN INCHES WG 1 1.5 2 2.5 2.75 1473 2488 4226 5581 1341 2228 3945 5182 1178 1899 3575 4760 3061 4189 2766 3760 965 804

ExTENDED PRESSURE PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL USGF-160XP A 26 B 2878 C* 2934 D 1938 ROOF OPENING 1812 x 1812 MIN/MAX SONES @ RPM 1 IN. 1550 10.0 2525 22 1 968 2339 PERFORMANCE IN INCHES WG 1.5 2 2.5 3 3.25 2155 1946 1676 1221 810

*May be greater depending on motor. All dimensions in inches. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. Greenheck Fan Corporation certifies that the Model USGF fan shown herein is licensed to bear For complete product information the AMCA Seal. The ratings shown are based on refer to catalog Series C, or tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 contact your local representative. and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 UL/cUL 762 MH 11745-USGF

18

ROOF MOUNTED FANS

Sidewall Exhaust - CW/CW-HP/CWB/CWB-HP


These fans are ideal for exhausting contaminated air out and away from buildings. Fan wheels are centrifugal, backward-inclined, and constructed of aluminum. Model CW sidewall exhaust fans are the centrifugal direct drive type. Model CWB sidewall exhaust fans are the centrifugal belt drive type. Adjustable motor pulleys allow for final system balancing.
B**

PERFORMANCE
CW performance capabilities range from 70 cfm to 3,277 cfm and up to 1.5 in. wg of static pressure.

Wall Opening

CWB performance capabilities range from 258 cfm to 12,449 cfm and up to 2.75 in. wg of static pressure.

5in. *

*Note: 2 inches minimum. 5 inches when motorized damper is required.

CW CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL CW-060 CW-065 CW-070 CW-075 CW-080 CW-085 CW-090 CW-095 CW-098 CW-101 CW-121 CW-131 CW-141 CW-161 CW-180 CW-200 A 1838 1838 1838 1838 21 21 21 21 2478 2478 2478 2478 2878 2878 3538 3538 B** 1312 1312 1312 1312 1338 1338 1338 1514 2814 2814 2814 2814 2934 2934 2858 2858 C 1434 1434 1434 1434 1778 1778 1778 1778 1934 1934 1934 1934 2218 2218 2734 2734 WALL OPENING 812 x 812 812 x 812 812 x 812 812 x 812 1012 x 1012 1012 x 1012 1012 x 1012 1012 x 1012 1212 x 1212 1212 x 1212 1212 x 1212 1212 x 1212 1512 x 1512 1512 x 1512 1712 x 1712 1712 x 1712

n Performance for available in stock sizes is shown on page 21 PERFORMANCE 0 .125 .25 133 81 197 164 128 180 109 266 222 172 250 171 369 325 269 287 188 424 359 291 325 247 133 480 431 376 389 305 182 574 520 461 549 451 306 811 744 677 711 570 381 1049 964 861 588 409 1180 1094 1017 732 625 481 1468 1422 1373 1015 905 781 2037 1979 1923 1180 1057 914 2366 2305 2244 1558 1427 1264 3125 3066 3005 2472 2315 2126 4959 4882 4806 3249 3074 2922 4307 4173 4045 4837 4587 4346 6412 6224 6036 IN INCHES WG .5 .75 1.5

DAMPER IN STOCK MIN/MAX SONES SIZE^ SIZES (n) RPM @ 0 IN. 1050 1.7 1550 4.2 1050 2.2 n 1550 4.7 8x8 1050 2.6 n 1550 5.5 1050 3.4 n 1550 6.0 1050 3.8 n 1550 7.3 1050 4.0 n 1550 7.5 10 x 10 1050 4.1 n 1550 7.8 1050 5.3 n 1550 9.6 860 8.4 1725 13.8 860 4.6 1725 13.3 12 x 12 860 5.3 n 1725 15.6 860 8.5 1725 18.8 860 7.3 n 1725 26 15 x 15 860 10.7 1725 30 860 12.3 1140 17.6 17 x 17 860 15.7 1140 24

235 312 501 616 824 586

1255 1129 1816 1710 1176 2122 1994 2865 1680 446 2474 3822 3815 5674 2711 2085 4463 3855 3470 3084 5283 3445

CW HIGH PRESSURE CONDENSED PERFORMANCE & DIMENSIONAL DATA in stock sizes not available for High Pressure
MODEL A B** 2934 2858 C 2218 2734 WALL OPENING 1512 x 1512 1712 x 1712 DAMPER SIZE^ 15 x 15 17 x 17 CW-161HP 2878 CW-180HP 3538 MIN/MAX RPM 1140 1725 1725 SONES @ 0.5 in. 12.5 22 28 .5 1645 2787 4613 PERFORMANCE IN INCHES WG .75 1 1.25 1.5 1.75 2 1444 1175 2680 2560 2439 2310 2167 2003 4493 4353 4215 4078 3914 4340

**May be greater depending on motor. All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. ^Dampers should not be used in grease applications. Greenheck Fan Corporation certifies that the Models CW and CWB fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 UL/cUL 762 (size 98 and up) MH11745 - CW/CWB

For complete product information refer to catalog Series C, or contact your local representative.

ROOF MOUNTED FANS

19

Sidewall Exhaust - CW/CW-HP/CWB/CWB-HP


SERVICE CHART
CW-065 through 121 and 141 All sizes CW CWB-141 and 180 All sizes CWB standard and HP

IN NEXT 3 10 STOCK DAY DAY DAY


OPTIONS AND ACCESSORIES


Aluminum birdscreen Gravity and motorized dampers (In stock for CW up to size 240) Heat baffles (Belt drive) UL/cUL 705 Electrical UL/cUL 762 Grease (Size 098 and up) Nonstick wheels (Belt drive) Wall grille Speed controls (Direct drive) Relubricatable bearings (Belt drive) Dual drives NEMA-3R and EXP disconnect switches Greenheck coatings (See coatings page 119)

STANDARD CONSTRUCTION FEATURES


Aluminum housing Non-overloading backward-inclined aluminum wheel Birdscreen mounted to the discharge perimeter Removable mounting plate Ball bearing motors Motors and drives isolated on shock mounts Adjustable motor pulley Adjustable motor plate Fan shaft mounted in ball bearing pillow blocks Static-resistant belts Corrosion-resistant fasteners NEMA-1 disconnect

CWB STANDARD PERFORMANCE & DIMENSIONAL DATA


MODEL A B** C 1934 1934 1934 1934 2218 2218 2734 2734 3114 3114 WALL OPENING 1212 x 1212 1212 x 1212 1212 x 1212 1212 x 1212 1512 x 1512 1512 x 1512 1712 x 1712 1712 x 1712 2012 x 2012 2012 x 2012 n 15 x 15 n 17 x 17 12 x 12 DAMPER SIZE^ IN STOCK SIZES (n) CWB-098 2478 2814 CWB-101 2478 2814 CWB-121 2478 2814 CWB-131 2478 2814 CWB-141 2878 2934 CWB-161 2878 2934 CWB-180 3538 2858 CWB-200 3538 2858 CWB-220 422532 3378 CWB-240 422532 3378 CWB-300 50 36

n Performance for available in stock sizes is shown on page 21 PERFORMANCE MIN/MAX SONES @ RPM 0 IN. 0 .25 .5 650 8.1 445 1725 13.8 1180 1017 824 860 4.6 732 481 1820 14.3 1549 1459 1350 685 4.4 809 1725 15.6 2037 1923 1816 650 6.2 892 1645 17.9 2256 2128 2001 590 5.0 1069 1725 26 3125 3005 2865 730 8.1 2098 1669 1390 22 3996 3806 3584 630 7.1 2380 1861 1495 28 5648 5443 5254 500 6.2 2812 1822 1210 25 6806 6451 6108 450 7.3 3585 2624 955 25 7607 7202 6799 410 6.4 3717 2471 930 24 8431 7985 7536 355 6.9 5777 4227 765 24 12449 11904 11273 IN INCHES WG .75 1 2 586 1234 1106 1710 1571 1864 1684 2711 2539 3340 3078 5082 4921 3564 5748 5350 6347 5844 6953 6375 10554 9743

20 x 20 25 x 25

383/8 2512 x 2512

CWB HIGH PRESSURE PERFORMANCE & DIMENSIONAL DATA


MODEL CWB-101HP CWB-141HP CWB-161HP CWB-180HP CWB-200HP CWB-220HP CWB-240HP CWB-300HP A 2478 2878 2878 3538 3538 422532 422532 50 B** 2814 2934 2934 2858 2858 3378 3378 36 C 1934 2218 2218 2734 2734 3114 3114 3838 WALL OPENING 1212 x 1212 1512 x 1512 1512 x 1512 1712 x 1712 1712 x 1712 2012 x 2012 2012 x 2012 2512 x 2512 DAMPER MIN/MAX SONES @ SIZE^ RPM 0.5 IN. 1300 6.0 12 x 12 2580 16.8 895 6.1 2110 19.8 15 x 15 825 7.0 1690 21 795 8.3 1685 27 17 x 17 740 8.1 1400 23 650 8.6 1085 23 20 x 20 635 8.1 1070 22 460 7.3 25 x 25 885 23

in stock sizes not available for High Pressure PERFORMANCE IN INCHES WG .5 .75 1.25 1.75 2 2.25 2.75 335 1014 969 861 735 655 550 331 1592 1536 1409 1262 1178 1073 804 889 2722 2611 2365 2082 1899 1664 1570 4495 4369 4085 3768 3575 3325 2766 2024 5110 4898 4436 3880 3515 2909 1940 5920 5678 5061 4210 3573 3046 6404 6112 5407 4550 3625 3125 9014 8603 7678 6353

**May be greater depending on motor. All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. ^Dampers should not be used in grease applications.

20

ROOF MOUNTED FANS

Sidewall Exhaust - CW/CW-HP/CWB/CWB-HP


CW PERFORMANCE DATA - IN STOCK
MODEL CW-065-DGEX-QD 1/30 HP 3 Speed CW-070-DGEX-QD 1/30 HP 3 Speed CW-075-DGEX-QD 1/25 HP 3 Speed CW-080-DGEX-QD 1/20 HP 3 Speed CW-085-DGEX-QD 1/20 HP 3 Speed CW-090-DGEX-QD 1/15 HP 3 Speed CW-095-DGEX-QD 1/8 HP 3 Speed CW-121-BX-QD 1/6 HP CW-141-BX-QD 1/4 HP E G D E G D E G D E G D E G D E G D E G D B B RPM 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1140 1140 TS 2234 2765 3297 2234 2765 3297 2234 2765 3297 2990 3701 4413 2990 3701 4413 2990 3701 4413 2990 3701 4413 3898 4364 SONES @ 0 IN. 2.2 3.2 4.8 2.5 4.1 5.6 3.3 4.4 6.1 3.8 5.4 7.3 3.6 5.4 7.5 3.8 5.4 7.5 4.9 7.4 9.6 7.4 11.3 stock Model cW fans include birdscreen, disconnect switch, UL/cUL 705 label. MAX BHP .009 .017 .028 .008 .015 .026 .012 .024 .039 .016 .031 .054 .018 .035 .061 .027 .052 .088 .037 .072 .121 0.14 0.29 PERFORMANCE IN INCHES WG 0 180 223 266 250 309 369 287 356 424 325 403 480 389 482 574 550 680 811 711 880 1049 1346 2064 .125 109 170 222 172 255 325 188 279 359 248 343 431 305 416 520 450 600 744 569 773 964 1260 1972 185 291 133 272 376 182 340 462 306 516 677 381 641 861 1179 1864 484 746 1091 1744 200 616 980 1604 443 833 1429 1166 391 603 501 347 235 395 313 161 173 315 236 204 152 269 160 97 172 95 .25 .375 .5 .625 .75

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

CWB PERFORMANCE DATA - IN STOCK


MODEL HP RPM 590 1090 1200 1400 1590 1725 740 830 960 1070 1200 1360 1480 TS 2259 4173 4594 5360 6087 6605 3584 4019 4649 5182 5811 6586 7168 SONES @ MAX 0 IN. BHP 7.3 10.7 12.1 15.2 19.9 26 9.1 11.4 14.2 16.4 18.8 22 26 0.04 0.25 0.34 0.53 0.78 1.0 0.25 0.36 0.55 0.77 1.08 1.58 2.03 0 1069 1975 2174 2537 2881 3125 2795 3135 3626 4042 4533 5137 5591 .125 851 1877 2088 2465 2817 3066 2596 2954 3466 3898 4405 5024 5487

stock model cWB fans include birdscreen, disconnect switch, UL/cUL762 and heat baffle. PERFORMANCE IN INCHES WG .25 .375 .5 .75 1 1.25 1.5 1.75

1763 1987 2382 2748 3005 2422 2799 3323 3765 4281 4911 5383

1633 1875 2292 2674 2936 2115 2575 3197 3645 4168 4809 5284

1476 1749 2196 2592 2865 1723 2315 2981 3533 4066 4710 5193 2487 3113 3778 4531 5021 2613 3411 4229 4845 2948 3909 4517 1410 1974 2420 2711 1675 2213 2539 1952 2339 2085 1704

CWB-141-LMDG-QD 590-1590 RPM

1 1 3

3 2

1
1 1 1

4 3

2 4

CWB-180-LMDG-QD 545-1480 RPM

1 1 2
1

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

ROOF MOUNTED FANS

21

Propeller Upblast Roof Exhaust Fans - RDU/RBU/RBUMO


Upblast propeller roof exhaust fans are designed to discharge contaminants up and away from the building for most commercial jobs and many industrial applications. These roof exhaust fans include both belt and direct drive fans with steel or aluminum blades. Models RBU and RBUMO are belt drive fans that offer the ability to adjust fan speed for system balancing if necessary. These models also offer more flexibility in speeds and motor selections. Model RBU has the motor in the airstream. Model RBUMO has the motor out of the airstream, which allows for high temperature air to be exhausted. RDU direct drive fans are often preferred for jobs where maintenance access is difficult. Maintenance costs are generally lower with direct drive fans since there are no belts or bearings to replace and no pulleys to adjust.

PERFORMANCE
RBU and RBUMO performance capabilities range from 3,100 cfm to 64,000 cfm and up to 1 in. wg of static pressure. RDU performance capabilities range from 2,800 cfm to 43,400 cfm and up to 1 in. wg of static pressure.

RBU
A

RBUMO
A

B B

SERVICE CHART
RDU/RBU/RBUMO All Models

5 DAY

10 DAY

Curb Cap

Curb Cap

RBUMO STANDARD CONSTRUCTION FEATURES


Fan base, motor cover and windband of galvanized steel Panel and drive frame assemblies of galvanized steel for sizes 20 to 48, painted steel for sizes 54 and 60 Galvanized steel windband with built-in damper stops Aluminum butterfly dampers Fabricated steel propeller Ball bearing motors Adjustable motor plate Variable pitch motor pulley Relubricatable bearings Static-resistant belts Corrosion-resistant fasteners

RDU STANDARD CONSTRUCTION FEATURES


Curb cap, drive frame and windband of galvanized construction Galvanized steel windband with built-in damper stops Aluminum butterfly dampers Cast aluminum airfoil blade propeller Ball bearing motors Corrosion-resistant fasteners

RBU STANDARD CONSTRUCTION FEATURES


Curb caps and drive frame assemblies of galvanized steel for sizes 20 to 48, painted steel for sizes 54 and 60 Galvanized steel windband with built-in damper stops Aluminum butterfly dampers Fabricated steel propeller Ball bearing motors Adjustable motor plate Variable pitch motor pulley Fan shaft mounted in pillow block bearings with grease fittings Static-resistant belts Corrosion-resistant fasteners

OPTIONS AND ACCESSORIES


UL/cUL 705 Electrical Inlet and outlet guards Extended lube lines Grease fittings for shaft bearings Bearings with high temp grease & fittings Dual drives Belt tube Aluminum propellers Galvanized butterfly dampers Curb seal Tie-down points Magnetic damper latches Fusible link damper lifters Roof curbs and adaptors High temperature options (level 2 and 3 - RBUMO) Greenheck coatings (See coatings page 19) 1
Greenheck Fan Corporation certifies that the RBU, RBUMO, and RDU models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.
UL/cUL 705 E40001-RBU, RBUMO, RDU

For complete product information refer to catalog Propeller Upblast Roof Fans - Model RBU, RBUMO, RDU and RGU, or contact your local representative.
22
ROOF MOUNTED FANS

RDU/RBU/RBUMO
RBU STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA
MODEL A B C LEVEL
1&2 RBU-20 271/4 24 15 3 15

CURB ROOF SONES MAX LEVEL CAP OPENING @ 0 IN. RPM


30 24 1L 1H 2L 2H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 2L 3L 3H 2L 3L 3H 2L 3L 3H 3L 3H 19.3 21 19.3 21 18.2 28 22 32 24 28 18 27 30 34 38 50 20 28 29 41 61 66 39 33 57 30 45 51 30 50 54 43 48 1084 1443 1084 1443 808 1351 924 1477 1135 1460 695 963 964 1213 1154 1471 547 806 689 1014 976 1401 718 652 1011 594 690 876 496 609 811 504 673

PERFORMANCE IN INCHES WG 0
5235 4295 5235 4295 6791 7382 7766 8071 8900 8358 11108 10943 15408 13783 17745 16466 15252 16441 19212 20683 26247 23827 32495 26765 28701 37987 44597 40049 44670 56220 52094 64326 58475

.125
4616 4041 4616 4041 5985 7037 7078 7755 8197 7931 9534 10166 14272 13173 16855 15907 13326 15195 17866 19637 25093 23230 30584 24942 27743 36154 42591 38737 41495 53570 50598 61083 56434

.25
3669 3669

.5

.75

RBU-24

311/8

26

151/2

163/4

34

28

RBU-30

373/8

30

151/2

163/4

40

34

6491 6127 7286 6411 7427 7459 6435 7845 9279 7021 13148 12515 11071 15865 15355 14335 13830 15917 18743 23979 22633 28793 22691 26759 33838 40288 37415 37122 50445 49059 56176 54119

4404

9315 13226 11816

RBU-36

431/2

33

163/4

163/4

46

40

RBU-42 RBU-48 RBU-54 RBU-60

495/6 56 625/8 683/4

38 40 45 48

193/8 193/8 191/4 211/4

237/8 237/8 267/8 27

52 58 661/2 721/2

46 52 60 66

16145 21093 21037 23522 24540 28240 35204 34563 42530 44746 48865

19260 14105 21672 29650 31092 27190 40046 43082

17598

27129 35353 35057

All dimensions in inches.

RBUMO STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL
RBUMO-20

A
271/4

B
431/2

C
193/4

CURB CAP
291/2

ROOF OPENING
24

LEVEL
1L 1H 2L 2H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 2L 3L 3H 2L 3L 3H 2H 3L 3H 3L 3H

SONES @ 0 IN.
18.3 19.6 18.3 19.6 17.7 24 22 29 23 26 17.9 26 28 32 36 49 19.3 27 28 39 49 61 38 42 53 29 40 47 34 46 50 40 46

MAX RPM
1060 1393 1060 1393 771 1259 883 1377 1089 1370 673 929 933 1167 1109 1420 530 784 668 988 943 1343 701 750 960 587 676 842 585 591 776 493 650

0
4797 3937 4797 3937 6234 6540 7140 7153 7827 7163 9706 10221 13456 12839 15679 15223 14236 15501 17943 19535 24356 22439 29635 29671 26600 34761 40135 37206 38905 51679 48021 61784 55174

PERFORMANCE IN INCHES WG .125 .25 .5 .75


3979 3475 3979 3475 5271 6066 6308 6723 7094 6707 8202 9265 12436 12092 14675 14657 12403 14137 16499 18453 23220 21888 28136 27925 25403 32809 38262 35684 36257 48380 46336 57265 52967

RBUMO-24

311/8

455/6

171/2

331/2

28

5530 5332 6273 6223 6208

5096 4968

RBUMO-30

373/8

513/4

191/2

391/2

34

8301 11279 11308 9633 13659 14044 12712 11285 12677 14852 17368 22077 21337 26190 26138 24222 30166 35865 34269 33184 44763 44533 51778 50458

9613

RBUMO-36

431/2

55

191/2

451/2

40

RBUMO-42

495/6

595/8

195/8

511/2

46

RBUMO-48

56

635/6

213/4

571/2

52

14948 19334 19655 21646 21824 21531 24091 30524 31241

17885 15694 18596 21518 27087

15850

14837

20830

RBUMO-54 RBUMO-60

625/8 683/4

705/8 75

223/4 23

66 72

60 66

36436 40247 35308 44728 37535 26609

Please note: Optimum selections shown in bold. All dimensions in inches. *May be greater depending on motor. **RBUMO = 1/2 in. less. Dimension A - given is the inside dimensions of the curb cap. The roof curb should be 11/2 in. less than the curb cap to allow for roofing and flashing. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.
ROOF MOUNTED FANS

23

Nonpowered Gravity Upblast Ventilator - RGU


Model RGU is an upblast ventilator designed for use as a weatherproof outlet on vertical high-velocity exhaust systems. They can be furnished without the curb cap for mounting directly on round stacks.

SERVICE CHART
All Sizes

5 DAY

10 DAY

RGU STANDARD CONSTRUCTION FEATURES


Standard construction is heavy gauge galvanized steel. Nine sizes are available, corresponding to powered units in sizes18-60. Fusible link damper lifters are available to allow RGU units to function as heat and smoke relief vents.
A

SIZE
18 20 24 30 36 42 48 54 60

B
22 24 26 30 33 38 40 45 48

C
20 4 2114 24 2634 2914 C 3414 3414 4014 4318
1

D
1 4 134 134 134 134 134 134 134 134
3

E
18 2 2012 2412 3058 3658 4234 4812 55 61
1

CURB CAP
28 30 34 40 46 52 58 6612 7212

RECOMMENDED ROOF OPENING


22 24 28 34 40 46 52 60 66

RGU with curb cap


B

25 2714 3118 3738 4312 4878 56 6258 6834

D Curb Cap A

RGU Performance
0.60
RGU-18 RGU-48 RGU-42 RGU-36 RGU-20 RGU-24 RGU-30 RGU-54 RGU-60

Static Pressure Drop (in. wg)

RGU without curb cap B

0.55 0.50 0.45 0.40 0.35 0.30 0.25 0.20 0.15 0.10 0.05 0.00

MINIMUM CFM REQUIRED TO OPEN DAMPERS


SIZE
18 20 24 30 36 42 48 54 60

10,000

20,000

30,000

40,000

50,000

60,000

DAMPER ALUMINUM GALVANIZED


2750 3170 3950 6050 7620 11050 12820 21430 24820 3520 4090 5220 7130 10980 13550 16420 21430 24820

Volume (cfm)

For complete product information refer to catalog Propeller Upblast Roof Fans - Model RBU, RBUMO, RDU and RGU, or contact your local representative.

24

ROOF MOUNTED FANS

Tube Axial Upblast Roof Exhaust - TAUD/TAUB/TAUB-CA


Model TAUD direct drive tube axial upblast roof exhaust fans feature cast aluminum propellers and are designed to efficiently remove and disperse contaminated air. They are best suited for exhausting relatively clean, dry and cool air. Model TAUB belt drive tube axial upblast roof exhaust fans are designed to efficiently remove and disperse contaminated air. The TAUB L/H is available with high temperature options that meet IRI, SBCCI, or can be UL listed as a Power Ventilator for Smoke Control Systems. STANDARD TAUD TAUB-CA TAUB-L/H CONSTRUCTION D FEATURES AMCA Certified n n n performance Permatector coating n n n Cast aluminum airfoil n n propeller B Fabricated steel propeller n C Polished steel shaft n n Heavy-gauge curb cap, tubular housing, and n n n windband
21/2 in. A

n n

n n n n n n

Steel or aluminum butterfly backdraft dampers Adjustable motor plate Corrosion-resistant fasteners Cast iron pillow block bearings Extended lube lines Minimum bearing life L(10) 40,000 hrs

TUBE AxIAL PERFORMANCE


TAUD performance capabilities are 2,800 to 46,000 cfm and up to 1 in. wg of static pressure. TAUB-L/H performance capabilities are 5,000 to 60,000 cfm and up to 1 in. wg of static pressure. TAUB-CA performance capabilities are 3,000 to 74,000 cfm and up to 1 in. wg of static pressure.

n n n n

TAUD STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL
TAUD-18 TAUD-20 TAUD-24 TAUD-30 TAUD-36 TAUD-42 TAUD-48

A
26 30 34 40 46 52 58

B
46 461/4 521/4 577/8 623/4 697/8 753/8

C
221/4 23 257/8 285/8 31 331/4 375/8

D
251/4 27 307/8 371/8 431/4 495/8 553/4

ROOF OPENING
201/2 x 201/2 221/2 x 221/2 261/2 x 261/2 321/2 x 321/2 381/2 x 381/2 441/2 x 441/2 501/2 x 501/2

MIN/MAX RPM
1140 1725 1140 1725 860 1140 1725 860 1140 1725 860 1140 1725 680 860 1140 680 860 1140

3221 4584 4448 5568 5090 7383 10695 10898 13691 18144 19008 22914 29680 21959 25086 36814 30936 36360 46455

PERFORMANCE IN INCHES WG .125 .25 .5 .75


2739 4348 3989 5267 4038 6740 10288 9636 12762 17485 17401 21960 28872 19186 23024 35197 27426 33983 44268 4108 4926 6072 9901 8215 11812 16789 15604 20736 28042 15981 20771 33468 23440 31147 42243 3536 4187 9073 9695 15137 18177 26197 14921 30373 24197 38672 8095 13450 14977 24193 25503 32978

7603 11405 22056

26099

All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). Greenheck Fan Corporation certifies that the models TAUD and TAUB-CA tube axial fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Greenheck Fan Corporation certifies that the TAUB-L and TAUB-H fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 E40001 TAUD/TAUB

UL Listed Power Ventilators for Smoke Control Systems (TAUB-L/H)

ROOF MOUNTED FANS

25

Tube Axial Upblast Roof Exhaust - TAUD/TAUB/TAUB-CA


Model TAUD direct drive tube axial upblast roof exhaust fans feature cast aluminum propellers and are designed to efficiently remove and disperse contaminated air. They are best suited for exhausting relatively clean, dry and cool air. 10 Model TAUB belt drive tube axial upblast roof exhaust fans are designed to SERVICE CHART DAY efficiently remove and disperse contaminated air. The TAUB L/H is available with high temperature options that meet IRI, SBCCI, or can be UL Listed as a TAUD/TAUB-CA/TAUB-L/H Power Ventilator for Smoke Control Systems.

OPTIONS AND ACCESSORIES


UL/cUL - 705 (Electrical) Shaft seal (TAUB-CA and TAUB-L/H) Inlet and outlet guards Access doors - bolted and hinged Magnetic damper latches Fusible link damper lifter Curb seal Bearings with high temperature grease and zerk (TAUB L/H) Tie-down points Roof curbs (See page 38-39) NEMA-3R disconnect switches High temperature options (TAUB-L/H) Option I - 200F (93C) to 500F (260C) Continuous Operation Option II - 500F (260C) for minimum of 4 hours Option III - 1000F (538C) for minimum of 15 minutes Option IV - UL Listed Power Ventilators for Smoke Control Systems Greenheck coatings (See coatings page 119)

TAUB-CA PERFORMANCE & DIMENSIONAL DATA


MODEL
TAUB-CA-18 TAUB-CA-20 TAUB-CA-24 TAUB-CA-30 TAUB-CA-36 TAUB-CA-42 TAUB-CA-48 TAUB-CA-54 TAUB-CA-60

A
26 30 34 40 46 52 58 64 70

B
46 461/4 521/4 577/8 623/4 697/8 753/8 841/4 903/8

C
221/4 23 257/8 285/8 31 331/4 375/8 411/2 443/4

D
251/4 27 307/8 371/8 431/4 495/8 553/4 625/8 687/8

ROOF OPENING
201/2 x 201/2 221/2 x 221/2 261/2 x 261/2 321/2 x 321/2 381/2 x 381/2 441/2 x 441/2 501/2 x 501/2 561/2 x 561/2 621/2 x 621/2

MIN/MAX RPM
1400 2235 1265 2190 1015 1975 820 1810 745 1700 640 1580 615 1550 585 1270 415 950

3288 4757 3679 6369 5241 10199 7863 17357 11254 25682 13876 34258 18744 47242 29622 64308 32356 74069

PERFORMANCE IN INCHES WG .125 .25 .5 .75 1.25


3079 4615 3357 6201 4695 9978 6806 16899 9741 25051 11666 33374 15794 46125 25840 62672 27799 72235 4468 4136 3778 5157 8436 14455 21625 28888 40285 53381 62059 6894 12149 17981 24735 34427 43216 52483

6016 5605 4059 9682 9071 5587 16422 15453 7658 24415 23061 32490 11957 45008 20669 61022 22311 70402 30737 42744 57557 66235

All dimensions in inches. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

TAUB-L/H PERFORMANCE & DIMENSIONAL DATA


MODEL TAUB-24L TAUB-24H TAUB-30L TAUB-30H TAUB-36L TAUB-36H TAUB-42L TAUB-42H TAUB-48L TAUB-48H TAUB-54L TAUB-54H TAUB-60L TAUB-60H A 34 34 40 40 46 46 52 52 58 58 64 64 70 70 B 521/4 521/4 577/8 577/8 623/4 623/4 697/8 697/8 753/8 753/8 841/4 841/4 903/8 903/8 C 257/8 257/8 285/8 285/8 31 31 331/4 331/4 375/8 375/8 411/2 411/2 443/4 443/4 D 307/8 307/8 371/8 371/8 431/4 431/4 495/8 495/8 553/4 553/4 625/8 625/8 687/8 687/8 MIN/MAX RPM 830 1085 1120 1935 645 1090 800 1635 525 790 675 1275 460 735 505 1030 355 645 450 905 335 595 400 845 315 515 380 735 SONES @ 0 in. 16.4 27 23 48 15.8 39 20 62 15.2 27 21 59 14.6 32 17.7 55 15.2 37 23 65 19.3 53 22 75 19.7 47 23 68 0 5230 6837 5671 9797 8201 13859 7918 16183 12232 18406 10993 20765 17130 27370 14273 29111 20588 37407 19562 39340 27859 49480 25557 53990 32133 52534 31149 60249 PERFORMANCE IN INCHES WG .125 .25 .5 .75 4378 6241 5395 5111 4536 9450 9122 8508 7826 6784 13112 12294 6962 5793 15751 15300 14317 13275 10170 17050 15725 9732 7998 20131 19479 18046 16295 14338 25873 24086 12245 9527 28202 27270 25162 22788 16454 35386 33209 17103 13779 38238 37084 34466 31349 22275 46830 43652 22388 18006 52494 51022 48133 44364 48397 27226 57945 21706 56057 1.25
All dimensions in inches. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

10448

35337

52062

47485

For complete product information refer to the CAPS program or to catalogs Models TAUD & TAUB-CA and Model TAUB-L/H, or contact your local representative.
26
ROOF MOUNTED FANS

Supply Air Fan - SAF


The SAF (Supply Air Fan) is a roof mounted, nontempered, filtered, belt driven make-up air unit. This cost effective forward-curved supply fan performs similar to the RSF and KSFB. Housing is straight sided heavy-gauge galvanized steel.

SERVICE CHART
SAF-110 through 118 SAF-120

IN STOCK

10 DAY

PERFORMANCE
Performance capabilities range from 725 to 14,000 cfm and up to 3.5 in. wg of static pressure.
E

SAF STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL SAF-110 SAF-112 SAF-115 SAF-118 SAF-120 A 30 34 34 40 46 B 25 32116 32116 36116 48116 C 21 16
1

n Performance for available in stock sizes is shown on page 28 CFM 820 1720 2620 1250 3000 3750 1300 2350 4800 2500 5500 8500 4000 9000 14000 .125 432 688 977 390 697 849 316 432 780 294 514 760 275 513 772 .25 549 757 1032 483 743 888 407 498 815 359 550 786 325 538 791 PERFORMANCE IN INCHES WG .5 1 1.5 2.5 3 883 843 962 546 610 466 620 831 414 591 1110 1026 800 743 553 687 1307 1179 952 851 772 1139 1042 928 1134 995 1060 3.5

D 22 2914 2914 32 351316

E 1 2
1

RECOMMENDED ROOF OPENING 16 2 x 16 2


1 1

STOCK SIZES (n) n

2738 2738 31116 44116

2 2 2 218

2012 x 2012 2612 x 2612 3212 x 3212 3812 x 3812

All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects filters in the airstream.

For complete product information refer to catalog Model SAF, or contact your local representative.

Greenheck Fan Corporation certifies that the Model SAF fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 E40001 - SAF

ROOF MOUNTED FANS

27

Supply Air Fan - SAF

STANDARD CONSTRUCTION FEATURES


Heavy-gauge galvanized steel housing Double-width, double-inlet forward-curved wheel Removable cover allows complete accessibility to blower assembly 1-inch washable aluminum filters, easily removable for cleaning Vibration isolation for entire blower assembly AMCA Certified Ratings Seal for Sound and Air Performance Mounted and wired NEMA-1 disconnect switch Lifting lugs Energy efficient motor UL/cUL 705 Electrical

OPTIONS AND ACCESSORIES


Duct adaptors (In Stock) Curb adaptors Gravity and motorized dampers (In stock) High-velocity supply dampers Galvanized roof curbs (In stock) Aluminum roof curbs (See pages 38-39) Curb extensions Replacement filter sets Curb seal Curb adapter/reducer

SAF PERFORMANCE DATA - IN STOCK


MODEL CFM 820 1180 SAF-110-LMDX-QD 1540 1900 2260 2620 1250 1750 SAF-112-LMDx-QD 2250 2750 3250 3750 1300 2000 SAF-115-LMDx-QD 2700 3400 4100 4800 2500 3700 SAF-118-LMDx-QD 4900 6100 7300 8500 OV 877 1263 1658 2033 2418 2803 1850 2590 3330 4070 4810 5550 2717 4180 5643 7106 8569 10032 7400 10952 14504 18056 21608 25160 MAX BHP 0.08 0.22 0.55 1.02 1.05 0.97 0.11 0.31 0.49 1.04 1.45 1.5 0.23 1.05 1.89 1.91 2.04 1.96 0.37 1.67 4.46 4.73 4.63 4.64 RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM RPM .125 432 525 632 745 859 977 390 459 549 647 748 849 316 387 479 577 677 780 294 376 466 563 662 760

in stock sizes are galvanized steel construction and include washable aluminum filters. UL/cUL 705. PERFORMANCE IN INCHES WG .25 549 616 707 809 920 1032 483 549 615 698 790 888 407 463 534 621 717 815 359 426 508 594 688 786 466 516 582 661 744 831 664 713 775 846 800 828 878 939 932 973 1034 1059 1127 682 745 810 880 962 546 586 642 712 785 781 821 870 935 934 970 1011 1098 990 1063 780 844 927 1023 1082 1140 1210 1328 .5 1 1.5 2 2.5 3

Performance certified is for Model SAF exhaust for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings include the effects of filters in the airstream. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels.

28

ROOF MOUNTED FANS

Roof Supply Fans - RSF/RSFP


Models RSF and RSFP are roof mounted, filtered supply fans designed to provide efficient and economical make-up air. Galvanized steel housings are designed for maximum airflow and weather protection.

PERFORMANCE
Performance capabilities range from 650 to 14,300 cfm and up to 2 in. wg of static pressure.

BL

CL

RSF
A 21/2 in.

RSFP
A 2 1/2 in.

RSF STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL A (Sq.) B (Sq.) C RECOMMENDED ROOF OPENING DAMPER SIZE CFM 650 RSF-90 26 3518 2314 15 x 15 12 x 12 1530 2300 700 RSF-100 30 41 8
1

PERFORMANCE IN INCHES WG .125 435 707 994 377 796 1052 330 615 844 274 516 708 241 478 665 200 488 609 .25 569 783 1048 505 852 1089 430 664 877 363 588 739 317 516 687 266 509 626 553 639 719 794 581 691 799 901 641 784 913 1030 760 930 1079 1213 957 1146 1314 1468 924 1172 1385 .5 1 1.5 2

23 4
1

17 x 17

14 x 14

2500 3400 1150

RSF-120

34

4718

2714

21 x 21

18 x 18

3220 4600 1625

RSF-150

40

5318

3114

23 x 23

20 x 20

4730 6800 2450

RSF-180

46

6118

3414

29 x 29

26 x 26

7220 10400 2900

RSF-200

52

73 8
1

39 4
1

33 x 33

30 x 30

11260 14300

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings include the effects of 1 in. aluminum filters. Greenheck Fan Corporation certifies that the RSF and RSFP models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
UL/cUL 705 E40001 - RSF

For complete product information refer to catalog Models RSF & RSFP, or contact your local representative.

ROOF MOUNTED FANS

29

Roof Supply Fans - RSF/RSFP


5 DAY

SERVICE CHART
RSF/RSFP - All Models and Sizes

10 DAY

OPTIONS AND ACCESSORIES


Duct adaptors Performance baffle Gravity and motorized dampers High-velocity supply dampers Galvanized and aluminum roof curbs (See pages 38-39) Aluminum construction 2 in. washable aluminum supply filters Replacement filter sets UL/cUL 705 Electrical Tie-down points Curb adaptors Greenheck coatings (See coatings page 119)

STANDARD CONSTRUCTION FEATURES


Heavy-gauge galvanized steel housing Double-width, double-inlet forward-curved wheel Removable, insulated cover with quick release latches allows complete accessibility for filters and blower assembly Washable aluminum filters, easily removable for cleaning Vibration isolation for entire blower assembly AMCA Certified ratings seal for air performance

RSFP STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL A (Sq.) BL (Sq.) CL RECOMMENDED ROOF OPENING DAMPER SIZE CFM 650 RSFP-90 26 3178 2538 15 x 15 12 x 12 1530 2300 700 RSFP-100 30 3578 2538 17 x 17 14 x 14 2500 3400 1150 RSFP-120 34 3978 2938 21 x 21 18 x 18 3220 4600 1625 RSFP-150 40 45 8
7

PERFORMANCE IN INCHES WG .125 435 707 994 377 796 1052 330 615 844 274 516 708 241 478 665 200 488 609 .25 569 783 1048 505 852 1089 430 664 877 363 588 739 317 516 687 266 509 626 553 639 719 794 581 691 799 901 641 784 913 1030 760 930 1079 1213 957 1146 1314 1468 924 1172 1385 .5 1 1.5 2

33 8
3

23 x 23

20 x 20

4730 6800 2450

RSFP-180

46

5178

3538

29 x 29

26 x 26

7220 10400 2900

RSFP-200

52

58316

4038

33 x 33

30 x 30

11260 14300

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings include the effects of 1 in. aluminum filters.

30

ROOF MOUNTED FANS

Hooded Propeller Roof Fans - Models R/RB


Hooded propeller roof fans include both belt and direct drive fans with fabricated steel, fabricated aluminum, or cast aluminum blades. A variety of model configurations are available to handle exhaust and supply requirements. Belt drive fans offer the ability to adjust fan speed for system balancing if necessary. Direct drive fans are often preferred for jobs where maintenance access is difficult. Hooded propeller roof fans can be used for supply or filtered supply with either belt or direct drive units. They can operate from general ventilation up to industrial duty applications with airstream temperatures up to 130F.

SERVICE CHART
R/RB/RBC All Models

5 DAY

10 DAY

PERFORMANCE
Performance capabilities range from 580 cfm to 86,600 cfm and up to 1.5 in. wg of static pressure.

Shown with tall base option.

R/RB STANDARD CONSTRUCTION FEATURES


Motors are heavy-duty ball bearing type Fasteners are corrosion-resistant Galvanized steel hood and base w/galvanized birdscreen Galvanized steel with one piece drawn venturi Level 1 & 2 galvanized and riveted steel blades Level 3 heavy duty, welded and reinforced steel blades

TB

Tall Base Option A sq. L 2 1/2 in.

OPTIONS AND ACCESSORIES


Tall base Aluminum housings and propellers Safety guard Hood insulation UL/cUL 705 Electrical Extended and 1-point wiring Aluminum and galvanized roof curbs Insect screen bases Curb adaptors Rubber curb cap stripping Gravity and motorized dampers Extended lubrication lines (Belt Drive) Relubricatable bearings Dual drives Lifting lugs Greenheck coatings (See coatings page 119)
Tall Base Option A sq.

Belt Drive Model Number Code

The model number system is designed to completely identify the fan. The correct code letters must be specied to designate belt drive with exhaust, supply or ltered supply air congurations. The remainder of the model number is determined by the size and performance.

RB E - 2 L 24 - 7
Hooded Roof Propeller Belt Drive RB - Fabricated Propeller RBC - Cast Propeller (Level 3 only) E - Exhaust S - Supply F - Filtered Supply Level of Construction 1, 2, 3 Motor HP
4 = 1/4 3= 1/3 5= 1/2 7= 3/4 10 = 1 15 = 11/2 20 = 2 30 = 3 50 = 5 75 = 7 1/2 100 = 10 150= 15 200= 20

Fan Size Propeller Type L - Low H - High

For complete product information refer to catalog Hooded Propeller Roof Fans, or contact your local representative.

Greenheck Fan Corporation certifies that the R, RC, RB and RBC models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 E40001-R

ROOF MOUNTED FANS

31

Hooded Propeller Roof Fans - R & RB


RBE STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA
MODEL A SQ. 3014 B TALL BASE TB 4414 ROOF OPENING LEVEL SQ. 1L 1H 54 x 51 2212 2L 2H 1L 1H 2L 66 x 63 2612 2H 3L 3H 1L 1H 2L 75 x 75 3212 2H 3L 3H 1L 1H 2L 88 x 87 3812 2H 3L 3H 2H 3L 86 x 99 4412 3H 2H 3L 93 x 111 5012 3H 2H 3L 112 x 111 5612 3H 2H 3L 124 x 123 6212 3H 3L 136 x 135 7412 3H WxL ROOF OPENING SQ. 2212 MAX RPM 1025 1348 1171 1550 809 1152 888 1311 1278 1461 696 895 864 1125 996 1239 551 679 693 856 922 1357 907 868 898 734 690 842 562 650 795 559 582 677 508 606 SONES* 16.9 24 21 31 16.6 29 19.2 34 26 29 19.8 23 28 34 30 36 17.7 19.2 27 34 37 55 79 39 37 49 32 45 72 39 61 39 43 49 52 59 PERFORMANCE IN INCHES WG 0 4525 4015 5169 4617 6418 5407 7045 6153 7329 7019 9938 8717 12337 10958 11661 12938 13614 13075 17123 16484 19176 21459 28151 28038 26074 32802 33135 35819 37837 44393 45490 43719 56645 52948 82283 74799 .125 4095 3721 4791 4359 5767 5003 6450 5817 6926 6628 8653 7899 11329 10329 10987 12331 11667 11361 15591 14985 18329 20919 26951 27046 24812 31134 31527 34434 35477 42106 43977 41005 53978 50706 78328 72461 .25 3562 3422 4409 4109 4813 4473 5636 5383 6503 6193 6795 6992 10214 9632 10241 11712 9480 9946 13986 13893 17453 20380 25492 25859 23791 28991 29743 32994 32810 39669 42593 38264 50801 48472 74199 70066 .5 2733 3135 3560 3650 4430 5502 5313 4176 6789 8114 8026 10290 5287 10416 11342 15416 19309 22791 23097 21581 25394 25451 30055 26992 34363 39704 32285 43881 43809 65283 64146 .75 1759 2638 1 1.5

RBE-20

27

RBE-24

3414

29

4614

3144 3901 3697 5500 5042 8799 5177 7133 12092 17651 20004 19272 19109 20980 19395 27145 20503 27707 36651 25738 36745 38757 54396 58111

1986 2764

RBE-30

4014

34

5114

4359 3449 7147

RBE-36

4614

3912

5634

7865 15848 13887 16508 16755 15045 24209 12878 21765 32982 14495 27742 33604 42796 50925 8837 9159 6525 15499 10999 24770 16919 20643 27100

RBE-42 RBE-48 RBE-54 RBE-60 RBE-72

5214 5814 6414 7014 8212

4212 4312 49 50 53

5934 6034 6614 6714 7014

RBS STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL A SQ. 3014 B TALL BASE TB 4414 WxL LEVEL 1L 1H 2L 2H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 2H 3L 3H 2H 3L 3H 2H 3L 3H 2H 3L 3H 3L 3H MAX RPM 1052 1366 1205 1564 809 1157 891 1322 1278 1420 696 906 869 1136 995 1243 551 621 690 783 919 1417 907 870 899 734 689 851 562 646 779 559 582 695 504 620 SONES* 22 26 27 34 18.9 25 23 37 31 31 22 29 31 38 33 52 20 21 33 35 45 82 75 53 57 43 49 74 61 52 81 41 54 64 55 60 PERFORMANCE IN INCHES WG 0 5329 4325 6104 4952 7356 5779 8102 6603 8103 7447 10672 9271 13325 11624 12587 13248 15155 13746 18978 17331 20113 21831 31192 29703 28328 36484 34926 38705 42604 46542 50138 45346 59743 56378 86595 77652 .125 4701 4043 5571 4712 6463 5369 7325 6237 7726 7110 9677 8573 12660 11075 12039 12820 13822 12352 18190 16319 19360 21376 30325 28718 27235 34764 33453 37638 40619 44157 49057 42331 57010 53953 82944 73388 .25 3868 3684 4976 4404 5269 4945 6382 5902 7269 6762 7725 7808 11523 10501 11406 12366 10069 9206 16276 13933 18516 20922 29365 27706 26518 33369 31699 36572 37181 41722 47590 39160 54205 51528 78711 70946 .5 2772 3732 2862 2866 4652 5641 5852 4289 8793 8432 11109 9351 10084 15274 19775 24974 24914 24117 29323 25920 34182 27699 34737 42687 30942 45052 46256 67046 62164 5659 4791 8746 .75 1 1.5

RBS-20

27

54 x 51

RBS-24

3414

29

4614

66 x 63

2612

2926 4121

2025 2320

RBS-30

4014

34

5114

75 x 75

3212

6635

RBS-36

4614

3912

5634

88 x 87

3812

RBS-42 RBS-48 RBS-54 RBS-60 RBS-72

52 4
1

42 2
1

59 4
3

86 x 99 93 x 111 112 x 111 124 x 123 136 x 135

44 2
1

58 4
1

43 2
1

60 4
3

50 2
1

64 4
1

49 50 53

66 4
1

56 2
1

7014 8212

6714 7014

6212 7412

18438 20586 19835 19830 21121 19639 29385 16131 26145 36984 21853 36007 39019 52057 54641

16367 13856 15793 25478 19711 31629 27724 32640 45820 18704

All dimensions in inches. For performance for fan models RBCE, RBCS, RBCF, RBF, RCE3, RCS3, RE2, RS2 refer to catalog Hooded Propeller Roof Fans. *Sones shown apply to the highest cataloged cfm at each fan RPM. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

32

ROOF MOUNTED FANS

Reversible Fabra Fans - RPDR/RPBR


Reversible propeller roof fans include both belt and direct drive fans with and without filters. Models RPBR/RPDR are compatible with ducted and nonducted systems and offer the ability to exhaust or supply air on demand. Performance is equivalent in both the exhaust and supply modes. Belt drive fans offer the ability to adjust fan speed for system balancing if necessary. They also offer more flexibility in speeds and motor selections. Direct drive fans are often preferred for jobs where maintenance access is difficult. Maintenance costs are generally lower with direct drive fans since there are no belts or bearings to replace and no pulleys to adjust. STANDARD HOOD
WxL (Width x Length)

T A sq.

SERVICE CHART
RPDR/RPBR All Models

10 DAY

WxL (Width x Length)

FILTERED HOOD
WxL (Width x Length)

PERFORMANCE
RPBR performance capabilities range from 3,270 cfm to 70,500 cfm and up to 0.5 in. wg of static pressure. RPDR performance capabilities range from 3,400 cfm to 44,850 cfm and up to 0.5 in. wg of static pressure.

B Tall Base Option A sq. A sq. RPBRF (Filtered)

RPDR STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA CAST ALUMINUM PROPELLER
MODEL CFM RANGE @ 0.25 SP
2962-8354

WxL (STANDARD HOOD)


66 x 63

WxL (FILTERED HOOD)


66 x 63

ROOF OPENING

MIN/ MID/MAX RPM


870 1160 1750 870

PERFORMANCE IN INCHES WG SONES*


18.4 24 55 24 48 97 11.3 45 69 31 55 106 33 68 90 37 58 100

0
4562 6933 9177 7801 13345 17853 9774 14569 17821 14402 21556 29289 12084 31440 39237 18757 39868 44846

.125

.25

.375

.5

RPDR-24

3414

32

2612 x 2612

6165 8786 6741 12411 17326 7835 12821 16945 11925 19083 27398 8578 29089 37594 15817 36782 42867

4513 8354 4578 11135 16796 8909 15664 7245 15743 25583 26513 35930 11803 33249 40756

3227 7752 2076 8202 16147 5713 13982 12748 23206 20339 34192 28695 38281 35163 16291 32145 10505 10019 5895 15447 6927

RPDR-30

4570-16790

4014

34

74 x 75

78 x 87

3212 x 3212

1160 1750 680

RPDR-36

4060-15664

4614

3812

76 x 87

94 x 87

3812 x 3812

870 1160 680

RPDR-42

7245-25584

5214

43

86 x 99

100 x 99

4412 x 4412

870 1160 680

RPDR-48

9604-35930

5814

44

100 x 111

112 x 111

5012 x 5012

870 1160 680

RPDR-54

11821-40748

6414

4912

112 x 111

124 x 123

5612 x 5612

680 870

All dimensions in inches. *Sones shown apply to the highest cataloged cfm at each fan RPM.

ROOF MOUNTED FANS

33

Reversible Fabra Fans - RPDR/RPBR


STANDARD CONSTRUCTION FEATURES
Washable aluminum filters Base and hoods of galvanized steel Galvanized wire mesh birdscreen Double-venturi Reversible cast aluminum airfoil blade propeller Protective guards Ball bearing motors Adjustable motor plate Adjustable motor pulley Fan shaft mounted in ball bearing pillow blocks Static-resistant belts Corrosion-resistant fasteners Tie-down points. (Due to shipping size limitations, hoods for fans sizes 48 and larger will be shipped in sections. Hood assembly requires no special tools or training. Complete illustrated assembly and installation instructions are packed with each fan.)

OPTIONS AND ACCESSORIES


Filtered fan with 2 in. filters Aluminum housing Tall bases Motorized dampers Galvanized roof curbs (See pages 38-39) Aluminum roof curbs (See pages 38-39) Insect screen bases Rubber curb cap stripping Curb adaptors Extended lube lines (Belt Drive) Tie-down points Dual drives Hood insulation Greenheck coatings (See coatings page 119)

RPBR STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA CAST ALUMINUM PROPELLER
MODEL CFM RANGE @ 0.25 SP
2866-7679

WxL (STANDARD HOOD)


66 x 63

WxL (FILTERED HOOD)


66 x 63

ROOF OPENING

MIN/ MID/MAX SONES* RPM


850 24 34 48 19.5 38 63 21 48 83 20 47 75 22 48 86 22 47 73 30 49 79 24 56 86 1295 1635 650

PERFORMANCE IN INCHES WG 0
4457 6791 8574 6943 10682 15489 9602 15977 21739 11888 20805 28057 15117 25352 35587 21919 35344 45482 26801 38375 49034 34031 55551 70565 9609 14813 6731 14955 21021 6714 18756 26551 9863 23211 34108 16286 32897 43760 20935 35117 46569 20400 51205 67078 44148 63816 28724 58014 45701 28342 41542 14113 30229 43965 25640 40611 20748 36072 24564 38359 21011 34546 20633 32532 15240 30814 28809 15949 25002 11889 22725 20603 13411 20183 19081 17888 7900 14022 13125 11850

.125
3269 6241 8156

.25

.375

.5

RPBR-24

3414

32

2612 x 2612

5341 7680

4221 6912 6024

RPBR-30

7070-14022

4014

34

74 x 75

78 x 87

3212 x 3212

1000 1450 625

RPBR-36

9150-20183

4614

3812

76 x 87

94 x 87

3812 x 3812

1040 1415 500

RPBR-42

8993-25002

5214

43

86 x 99

100 x 99

4412 x 4412

875 1180 480

RPBR-48

7338-32532

5814

44

100 x 111

112 x 111

5012 x 5012

805 1130 400

RPBR-54 12437-41542

6414

4912

112 x 111

124 x 123

5612 x 5612

645 830 440

RPBR-60 14113-43965

7014

5012

124 x 123

136 x 135

6212 x 6212

630 805 340

RPBR-72 22926-63816

8014

53

136 x 135

136 x 147

7412 x 7412

555 705

All dimensions in inches. *Sones shown apply to the highest cataloged cfm at each fan RPM.

For complete product information refer to catalog Hooded Propeller Roof Fans, or contact your local representative.
34
ROOF MOUNTED FANS

Propeller Roof Rans - AE/AS


Models AE (Axial Exhaust) and AS (Axial Supply) spun aluminum direct drive fans are designed for economy and reliability in low pressure/low volume applications.

STANDARD CONSTRUCTION FEATURES


Aluminum housing and propeller Galvanized wire mesh birdscreen NEMA-1 disconnect Aluminum curb cap with prepunched holes Corrosion-resistant fastners ODP 115V motor UL/cUL 705 Electrical

SERVICE CHART
AE/AS - All Models

NEXT 3 DAY DAY


5 DAY

10 DAY

OPTIONS AND ACCESSORIES


Galvanized roof curbs (In Stock) Aluminum roof curbs (See pages 38-39) Gravity and motorized dampers (In Stock) Curb extensions UL/cUL 705 Electrical Curb adaptors/reducers Aluminum wire mesh birdscreen Speed controllers (In stock) NEMA-3R, NEMA-4 and NEMA-4X disconnect Greenheck coatings (See coatings page 19) 1
D

PERFORMANCE
Performance capabilities range from 200 cfm to 6,000 cfm and up to 1.0 in. wg of static pressure.

1 3/4 in.

AE STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL AE-10-420-A8 AE-12-433-B6 AE-12-433-A4 AE-14-438-B6 AE-14-438-A5 AE-16-428-B6 AE-16-428-A5 AE-18-433-B3 AE-18-433-A10 AE-20-430-B5 AE-20-430-A15 AE-24-422-B5 AE-24-431-B10 A 19 22 22 22 22 26 26 30 30 34 34 34 34 B 2458 2858 2858 28 8
5

C 1512 1612 1612 16 2


1

D 512 614 614 6 4


1

RECOMMENDED ROOF OPENING 1412 x 1412 1412 x 1412 1412 x 1412 16 2 x 16 2


1 1

HP
1 1 1 1 1 1 1 1

RPM 1750 1140 1750 1140 1750 1140 1750 1140 1750 1140 1750 1140 1140

SONES @ 0 IN. 9.6 5.1 9.0 8.2 16.8 10.5 17.9 11.7 28 11.3 23 17.2 19.8

0 550 1014 1556 1601 2457 1999 3068 2982 4578 3871 5943 5091 6042

.1 475 853 1460 1381 2332 1817 2958 2713 4395 3606 5785 4782 5714

PERFORMANCE IN INCHES WG .125 .25 .375 .5 .75 465 803 1437 1311 2298 1764 2928 2645 4349 3531 5745 4703 5626 347 376 1291 925 2093 1418 2771 2264 4141 3100 5507 4277 5137 255 144 1055 626 1875 904 2590 1669 3908 2301 5260 3813 4619 672 273 1603 682 2339 1276 3660 1925 5007 3279 4146 4246 2252 3136 1686 499 2935 1244 386 189

8 6

4 6 2

2858 3514 3514 35 4


1

1612 1714 1714 17 4


1

614 614 614 6 4


1

1612 x 1612 1812 x 1812 1812 x 1812 20 2 x 20 2


1 1

716

2 3

1257

3514 42 42 42 42

1714 1712 1712 17 2


1

614 614 614 6 4


1

2012 x 2012 2612 x 2612 2612 x 2612 26 2 x 26 2


1 1

1
1

2327

112
1

3295

1712

614

2612 x 2612

2028

AS STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL AS-10-420-A8 AS-12-420-A4 AS-12-433-A4 AS-14-428-A4 AS-14-440-A5 AS-16-420-A5 AS-16-428-A7 AS-18-427-A7 AS-18-431-A10 AS-20-428-B5 AS-20-428-A15 AS-24-418-B5 AS-24-430-B10 A 19 22 22 22 22 26 26 30 30 34 34 34 34 B 2458 2858 2858 28 8
5

C 1512 1612 1612 16 2


1

D 512 614 614 6 4


1

RECOMMENDED ROOF OPENING 1412 x 1412 1412 x 1412 1412 x 1412 16 2 x 16 2


1 1

HP
1 1 1 1 1 1 3 3

RPM 1750 1750 1750 1750 1750 1750 1750 1750 1750 1140 1750 1140 1140

SONES @ 0 IN. 7.9 9.6 11.4 16.1 20 20 21 30 31 16.7 29 24 29

0 503 929 1444 2041 2586 2353 2920 3906 4247 3488 5355 4569 5742

.1 413 835 1412 1940 2442 2229 2826 3739 4110 3202 5181 4289 5401

PERFORMANCE IN INCHES WG .125 .25 .375 .5 .75 401 813 1400 1912 2395 2195 2802 3690 4076 3125 5137 4215 5315 343 595 1203 1742 2176 2008 2602 3454 3846 2715 4886 3841 4929 280 415 953 1567 1971 1819 2376 3228 3526 2315 4648 3392 4556 641 1380 1799 1597 2188 2990 3259 1847 4408 2958 4131 3066 3830 1018 1380 1121 1693 2454 2724 188

8 4 4 4 2 2 4 4

2858 3514 3514 35 4


1

1612 1714 1714 17 4


1

614 614 614 6 4


1

1612 x 1612 1812 x 1812 1812 x 1812 20 2 x 20 2


1 1

1200

3514 42 42 42 42

1714 1712 1712 17 2


1

614 614 614 6 4


1

2012 x 2012 2612 x 2612 2612 x 2612 26 2 x 26 2


1 1

1
1

112
1

3272

1712

614

2612 x 2612

Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings include the effects of filters. Speed (RPM) shown is nominal. Performance is based on actual spped of test. UL/cUL 705 Greenheck Fan Corporation certifies that the AE E40001-AE/AS For complete product information and AS fans shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests refer to Propeller Hooded Roof and procedures performed in accordance with Fans - Series A, or contact your AMCA Publication 211 and AMCA Publication 311 local representative. and comply with the requirements of the AMCA Certified Ratings Program.
ROOF MOUNTED FANS

35

Gravity Ventilators
Spun Aluminum Gravity Ventilators - GRS/GRSF
Model GRS is an aluminum ventilator designed for intake (Model GRSI) or relief (Model GRSR) applications with either natural gravity or positive pressure systems. The GRS appearance blends with other Greenheck products and with its low silhouette, avoids the problem of detracting from architectural aesthetics. Exceptional design and construction features make this unit a rugged, efficient, and economical air inlet or outlet. Optional built-in flashing flange (model GRSF) with prepunched holes for quick and easy installations without a roof curb.

SERVICE CHART
GRS-8 through 30 GRS-36 through 48

IN NEXT 3 & 5 STOCK DAY DAY


10 DAY

OPTIONS AND ACCESSORIES


Gravity and motorized dampers (In stock) Galvanized roof curbs (In Stock) Aluminum roof curbs (See pages 38-39) Extended bases Rubber curb cap stripping Aluminum curb adaptors Hood insulation (1/2 in. and 1 in.) Insect screen in frame Greenheck coatings (See coatings page 119) GRS - Sizes 30 thru 48
B C D Dia. A D 1 (44) Dia. E

STANDARD CONSTRUCTION FEATURES

Aluminum housing Aluminum curb cap with prepunched mounting holes Recommended roof opening dimension is at least 2.5 in. larger than the damper size GRS - Sizes 8 thru 24
B

GRS with Optional Flashing Flange (Model GRSF) Sizes 8 thru 24


B C

D Dia. A

1 (44)

GRS DIMENSIONAL DATA


MODEL GRS-8 GRS-10 GRS-12 GRS-15 GRS-16 GRS-18 GRS-20 GRS-24 GRS-30 GRS-36 GRS-42 GRS-48 A 19 19 22 22 26 30 30 34 40 46 52 58 B 20 2
1

n in stock sizes include birdscreen


DIA. 8 4
1

C 7 4
1

D 1 2
1

E 20 4
1

THROAT AREA (FT2) 0.37 0.57 0.82 1.12 1.45 1.83 2.25 3.24 5.032 7.291 9.765 12.83

STOCK SIZES (n) n n n n n n n n n RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE RELIEF INTAKE

CAPACITIES (CFM) .04 231 178 331 279 468 400 663 553 870 742 1060 901 1284 1096 1879 1542 2281 2013 3279 2921 4672 3911 6211 5139 .06 282 218 406 342 573 490 811 677 1065 908 1298 1104 1572 1343 2301 1888 2794 2465 4016 3577 5722 4791 7607 6294 .08 326 252 468 395 662 566 937 782 1230 1049 1499 1274 1815 1550 2657 2180 3226 2847 4637 4130 6607 5532 8783 7268 .1 365 282 524 442 740 633 1048 874 1375 1173 1676 1425 2029 1733 2971 2438 3607 3183 5184 4618 7387 6185 9820 8126 .15 446 345 641 541 907 775 1283 1071 1685 1436 2052 1745 2486 2123 3638 2985 4418 3898 6349 5656 9047 7574 12027 9952 .2 516 398 741 624 1047 895 1481 1237 1945 1658 2370 2015 2870 2452 4201 3447 5101 4501 7331 6531 10447 8746 13888 11491 .25 576 445 828 698 1171 1001 1656 1383 2175 1854 2649 2253 3209 2741 4697 3854 5703 5032 8197 7301 11680 9779 15527 12848 .3 631 488 907 765 1282 1097 1814 1515 2382 2031 2902 2468 3515 3002 5145 4222 6247 5512 8979 7998 12795 10712 17009 14074 .35 682 527 980 826 1385 1184 1960 1636 2573 2194 3135 2665 3797 3243 5558 4560 6748 5954 9699 8639 13820 11570 18372 15201

2012 29 29 29 3512 3512 3814 48 5634 6314 72

734 10 10 11 934 1114 11 1834 2114 2414 2614

2 312 312 414 134 334 4 5716 6 614 612

2014 2314 2314 2714 3114 3114 3514

1014 1214 1414 1614 2014 2014 2412 3012 3612 4212 4812

All dimensions in inches (millimeters) and the weight in pounds (kilograms). NOTE: Models GRS-8 through GRS-24 have a one-piece cover and shroud. Access is gained through the removal of screws. Models GRS-30 through GRS-48 have a removable cover, separate from the shroud, to facilitate maintenance and servicing of dampers.

For complete product information refer to catalog Gravity Ventilators-Model GRS, or contact your local representative.

36

gRAViTy VENTilATORS

Fabrahoods - Gravity Intake/Relief - FGI/FGR


The low silhouette Fabrahoods are designed for intake (Model FGI) or relief (Model FGR) applications with either natural gravity or positive pressure systems. In appearance, load bearing strength, weather resistance and dimensional flexibility, the Fabrahood design is superior. The selections in this area are based on nonducted applications.

SERVICE CHART
Fabrahood Intake and Relief Sizes - 8 in. x 8 in. - 72 in. x 180 in.

5 DAY

10 DAY

STANDARD CONSTRUCTION FEATURES


Precision formed locked rib construction Available in aluminum or galvanized steel construction 0.5 in. galvanized steel mesh birdscreens Heavy-gauge galvanized steel support members Tie-down points Units with a throat size exceeding 60 in. x 120 in. will have 12 in. galvanized bases as standard Recommended roof opening dimension is at least 2.5 in. larger than the damper size

OPTIONS AND ACCESSORIES


12 in. high base Aluminum or galvanized roof curbs Gravity and motorized dampers Aluminum birdscreen or insect screen Fiberglass insulation (1/2 in. or 1 in.) 2 in. washable aluminum supply filters (10 day only) Greenheck coatings (See coatings page 19) 1

FABRAHOOD - GRAVITy INTAKE PERFORMANCE DATA


(Per Square Foot Of Throat Area)
INTAKE DUCTED NONDUCTED HOOD INTAKE VELOCITY THROAT VELOCITY .03 .053 235 475 .047 .085 297 600 STATIC PRESSURE DROP .071 .127 364 735 .089 .158 406 820 .119 .212 470 950 .149 .267 527 1065

FABRAHOOD - GRAVITy RELIEF PERFORMANCE DATA


(Per Square Foot Of Throat Area)
RELIEF DUCTED NONDUCTED HOOD/THROAT VELOCITY .024 .042 420 .043 .075 560 STATIC PRESSURE DROP .06 660 .084 .107 780 880 .136 .236 990 .105 .146 .186

For complete product information refer to catalog Gravity Ventilatiors-Models FGI & FGR, or contact your local representative.

gRAViTy VENTilATORS

37

Roof Curbs
Roof Curbs & Extensions
Greenheck roof curbs, extended bases, sound curbs, equipment supports, bases and adaptors are available from both stock and Quick Build programs in a variety of styles and materials.

OPTIONS AND ACCESSORIES


Damper Trays Insulation (All except GPE, VCE and GPFV) Step for Insulation (GPR only - up to 6 in.) Double-Shell Construction (All except AT and GPE) Single-Pitch (GPI, GPF and ATS) Ridge Mount (GPI, GPF and ATS)

ROOF TYPE/ APPLICATION


Flat, insulated or noninsulated roof decks Flat, pitched or ridged, insulated or non-insulated roof decks

DESCRIPTION

MODEL & SERVICE CHART


GPI - Galvanized 12 in. high, with or without damper tray, square sizes for stock fans GPI - Aluminum or galvanized, other heights, nonstock square and rectangular sizes

IN NEXT 3 & 5 STOCK DAY DAY


10 DAY

Welded, straight sided construction with rigid fiberglass insulation and 2 in. mounting flange

*
galvanized GPI curbs are available from Miami, FL stock

*18 in. high

Flat, noninsulated roof decks

Welded, canted construction with rigid fiberglass insulation

GPS - All types, sized to meet your requirements

Flat, pitched or ridged, noninsulated roof decks

Welded, straight sided construction with rigid fiberglass insulation and 5 in. mounting flange

GPF - All types, sized to meet your requirements

Flat, insulated roof decks

Welded, raised cant construction with rigid fiberglass insulation

GPR - All types, sized to meet your requirements

Adaptors/ Reducers

Used to match new fans to existing roof curbs. Welded galvanized steel or aluminum.

Curb Adaptors and Reducers

For complete product information refer to our Roof Curbs, Extensions and Equipment Supports catalog, or contact your local representative.

38

ROOF CURbS

Roof Curbs & Extensions


ROOF TYPE/ APPLICATION
Flat roof decks in kitchen applications Flat roof decks in kitchen applications Curb extensions in kitchen systems

DESCRIPTION
Welded, vented straight sided curb designed for use with the Greenheck Model CUBE fan to provide the 40 in. minimum discharge height above the roof line (per NFPA 96)

MODEL & IN SERVICE CHART STOCK


GPFV Galvanized, square sizes for stock fans GPFV - Aluminum or galvanized, other heights, nonstock square sizes

NEXT DAY

3&5 DAY

10 DAY

*Wisconsin only

Welded, vented curb VCE - Galvanized, square sizes for extension designed stock fans for use with an 8 in. high roof curb and the Greenheck Model VCE - Aluminum Curb extensions CUBE fan to provide or galvanized, the 40 in. minimum in kitchen other heights, discharge height systems nonstock square above the roof line sizes (per NFPA 96) Welded, with access door for easy access to the damper and damper actuator as well as fulfilling additional height requirements Welded aluminum or galvanized canted construction

Curb extensions

GPE/GPEx

Equipment supports

GESS/GESR/ES Equipment supports

Insulated and non-insulated flat roof decks, pitched roofs, curb extensions Flat, noninsulated roof decks for high-wind and hurricane zones Flat, noninsulated roof decks for high-wind and hurricane zones Specifically for Lab Exhaust Fans

Welded aluminum or galvanized canted ATS/ATR/ATE/ATI construction for curbs, Sound straight sided for attenuating curbs extensions with rigid fiberglass insulation

Welded straightsided, insulated, 5 in. flashing flange

H-GPF

Welded straightsided, insulated, 5 in. flashing flange with 12 gauge steel

SD-Curb

Welded, straight sided, insulated, 5 in. flashing flange

GPE-LE

ROOF CURbS

39

Inline, Ceiling and Sidewall Exhaust


Ceiling Exhaust - SP
Model SP ceiling exhaust fans are designed for clean air applications where low sound levels are desired. Low sound levels are achieved through quiet running forward-curved wheels.

SP-A
SP FANS A B C

SP-B
STANDARD FEATURES SERVICE CHART
Standard Construction Speed Control, Mounted & Wired Light, SP-A50, 70, 90, 110, 125 SP-B50, 80, 150 Light, SP-B70, 90, 110 Fan/CRD UL Listed Assembly 277 volt SP-A 110, 125, 190 277 volt SP-B 110, 150, 200 Contractor 4-Packs Contractor Packs-Housings (sizes B70-B110) - Miami Motion Sensor - Grille Mounted

SP-C
IN 3 10 STOCK DAY DAY

Backdraft Damper - Prevents unwanted backdrafts. Spring Loaded Aluminum Backdraft Damper - Eliminates rattling or unwanted backdrafts (sizes 110 and up). Outlet - Both square and round outlets are field rotatable from horizontal to vertical discharge. Round Outlet (4 or 6 in.) - up to size A90. Versatile for quick, easy connections. Power Assembly - Removes quickly for maintenance. External Electrical Access - Eliminates removing motor pack, saving installation time. Electrical Knockout - Eliminates drilling holes. Disconnect (Plug Type) - Servicing is quick and safe. Electrical Junction Box - Large for easy wiring. Attractive Designer Grille - Concealed attachment screws securely to fasten grille to housing for quiet, rattle free operation. Mounting Brackets - Fully adjustable for multiple installation types. Housing - Embossed galvanized steel for rigidity and low-profile for height restricted areas. PSC Compatible Motors - 50 cycle, 220v, and 240v options. 60 cycle, 115v, 208v, 220v, 230v, and 277v options. (Check factory for availability) 3 year Warranty UL listed for above showers w/ GFCI branch protected circuit

PERFORMANCE
Models SP-A, SP-B, and SP-C are compact exhaust fans with performance capabilities of 29 cfm to 1600 cfm and up to 1 in. wg.

OPTIONS AND ACCESSORIES


Grilles Lights Ceiling radiation dampers (CRD) Vibration isolation kits Speed controls Motion detectors Time delays Roof discharge accessories Wall discharge accessories Transitions Filters Contractor paks
note: see pages 44-47 for full stock accessory listing

40

CEiliNg, CAbiNET AND iNliNE FANS

Ceiling Exhaust - SP
B B B C C E A E A D D C C B A E D A E D C C B B A E E A D D C C D B B E EA A

B B C C E

SP-C50 A A D

B A SP-A110 through SP-A510 B E and SP-A710 & SP-A780 A


OUTLET D C E

SP-B50 through SP-B200

SP-A700, SP-A900 & SP-A1550

E E SP PERFORMANCE & DIMENSIONAL DATA - IN STOCK C


MODEL A 712 1378 1378 13 8
7

C 358 61516 61516 6 16


15

RPM AMPS WATTS 0.80 0.50 0.53 0.60 0.65 1.14 1.70 2.20 0.31 0.27 0.34 0.58 0.62 1.30 0.43 0.77 0.72 1.34 1.74 3.30 3.20 4.40 3.30 4.00 6.30 7.40 8.60

D SONES
@ 0 IN. 2.9 1.7 1.7 2.9 1.9 2.0 3.0 4.4 0.7 1.1 1.1 1.3 1.4 3.2 2.0 2.9 3.2 5.4 4.1 6.0 6.1 7.4 10.2 5.2 7.2 11.6 12.4

GRILLE SIZE 914 x 9 1478 x 1314 1478 x 1314 14 8 x 13 4


7 1

SP-C50-QD SP-B50-QD SP-B70-QD SP-B80-QD SP-B90-QD SP-B110-QD SP-B150-QD SP-B200-QD SP-A50-QD SP-A70-QD SP-A90-QD SP-A110-QD SP-A125-QD SP-A190-QD SP-A200-QD SP-A250-QD SP-A290-QD SP-A390-QD SP-A410-QD SP-A510-QD SP-A700-QD SP-A710-QD SP-A780-QD SP-A900-QD

712 1112 1112 11 2


1

3 dia. x 158 1680 4 dia. x 34 4 dia. x 34 4 dia. x 4


3

0.00 52 67 77 87 102 133 160 197 76 83 99 119 135 216 247 272 315 410 443 557 757 752 812 955

PERFORMANCE IN INCHES WG .100 .125 .250 .375 .500 .625 .750 1.00 49 54 71 80 93 114 156 195 51 70 88 110 123 197 226 252 293 395 413 512 730 714 783 907 48 51 68 78 89 111 156 195 48 67 85 106 121 192 220 246 287 392 405 501 723 701 776 897 47 41 57 69 75 98 154 191 30 42 62 89 105 167 197 228 258 369 351 439 700 653 741 842 134 172 211 232 345 306 392 680 588 704 774 886 325 650 486 665 701 797 663 613 320 625 582 560 397 142 186 207 325 105 158 176 308 68 119 125 280 25 44 30 50 61 59 96 152 188 40 54 45 94 150 184 44 30 92 147 181 85 139 166 51 92 128 30 38 29

46 38 45 54 50 80 129 173 18 20 29 49 53 113 48 83 81 135 121 224 350 285 348 285 420 786 818

625 675 900 700 950

1378 1378 13 8
7

1112 1112 11 2
1

71516 6 dia. x 114 71516 6 dia. x 114


15 1

1478 x 1314 1478 x 1314 1478 x 1314 1478 x 1314 1478 x 1314 1478 x 1314 1478 x 1314 14 8 x 13 4
7 1

7 16 6 dia. x 1 4 1050 71516 6 dia. x 114 1100 1158 1158 1158 10 2


1

1378 1314 1314 1314 13 4


1

1112 1058 1058 1058 10 8


5

6 6 6 8 8 8 8 8 8 8 8 8 1912 10 10 1834 1834 1834 1834

6 6 6 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8

700 850 900 950 1100 1400 900 1000 1050 1350 1000 1070 1100 1080 1600 950 1095 1450 1610

1314 1314 14 14 14 14 18 18 2358 18 18 2334

1058 1058 11 8
7

1012 1012 11 4
1

1478 x 1314 1478 x 1314 1478 x 1314 1478 x 1314 1478 x 1314 1478 x 1314 1938 x 1638 1938 x 1638 2518 x 1312 19 8 x 16 8
3 3

1178 1178 1178 1438 1438 1158 14 8


3

1114 1114 1114 1412 1412 1158 14 2


1

1438 1438 1438 1438 1438

1412 1412 1412 1412 1412

1938 x 1638 25 x 1638 25 x 1638 25 x 1638 25 x 1638

SP-A1050-QD 2334 SP-A1410-QD 2334 SP-A1550-QD 2334

1125 1059 1043 964

1455 1415 1404 1354 1308 1263 1219 1174 1607 1568 1558 1507 1449 1408 1369 1323

All dimensions in inches. Grille dimensions are for the designer grille except on model SP-C50 where the dimensions are shown for the decorative grille. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values are for installation type B: free inlet sone levels. The AMCA Certified Ratings Sound Seal applies to sone ratings only.

UL/cUL 507 E33599

Ceiling Exhaust Fans are also UL Listed for sizes 50 through 390 for above bathtub/shower with GFCI branch protected circuit. File No. E33599

Greenheck Fan Corporation certifies that the SP models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

For complete product information refer to catalog Models SP and CSP, or contact your local representative.
CEiliNg, CAbiNET AND iNliNE FANS

41

Inline Cabinet Exhaust - CSP


Model CSP inline cabinet fans are designed for clean air applications where low sound levels are desired. Low sound levels are achieved through quiet running forward-curved wheels.

PERFORMANCE
Models CSP-B110 through A3600 are duct mounted with performance capabilities of 77 cfm to 3,778 cfm and up to 1 in. wg of static pressure.

OPTIONS AND ACCESSORIES


Vibration isolation kits Speed controls Motion detectors Time delays Roof discharge accessories Wall discharge accessories Transitions
note: see pages 44-47 for full stock accessory listing

SERVICE CHART
G E C

IN STOCK

3 DAY

10 DAY

CSP-B110 through -A1550 - 115 Volt Mtr Construction CSP-A1750 through -A3600 CSP-B110 through -A190 with 277 Volt Motor
D dia.

D A

CSP-A

Inlet F xG C

CSP FANS STANDARD FEATURES A B


Aluminum Backdraft Damper - Prevents unwanted backdrafts. Spring Loaded Aluminum Backdraft Damper - Eliminates rattling or unwanted backdrafts.

CSP-B
B

Power Assembly - Removes quickly and is rotatable from horizontal to vertical discharge. External Electrical Access - Eliminates removing motor pack, saving installation time. Access Panel - Gain easy access to internal components once installed. Mounting Brackets - Fully adjustable for multiple installation types. Compatible with Speed Controllers 3 year Warranty UL listed for above showers w/ GFCI branch protected circuit.

CSP-A DOUBLE-SCROLL
42
CEiliNg, CAbiNET AND iNliNE FANS

Inline Cabinet Exhaust - CSP


CSP PERFORMANCE AND DIMENSIONAL DATA
MODEL CSP-B110 CSP-B150 CSP-B200 CSP-A110 CSP-A125 CSP-A190 CSP-A200 CSP-A250 CSP-A290 CSP-A390 CSP-A410 CSP-A510 CSP-A700 CSP-A710 CSP-A780 CSP-A900 CSP-A1050 CSP-A1410 CSP-A1550 CSP-A1750 CSP-A2150 CSP-A3600 A 1378 13 8
7

B 1112 11 2
1

C 71516 7 16
15

D 6 6 6 8 8 8 8 8 8 8 8 8 1912 10 10 1834 18 4
3

E 114 1 4
1

F 1014 10 4
1

G 314 3 4
1

RPM AMPS WATTS 950 1050 1100 950 1100 1400 900 1000 1050 1350 1000 1070 1100 1080 1600 950 1095 1450 1610 1130 1100 1100 1.14 1.70 2.20 0.62 0.63 1.10 0.43 0.79 0.71 1.33 1.87 3.11 3.20 4.40 3.77 4.87 6.65 7.80 8.32 6.60 7.80 7.10 80 129 173 51 55 100 48 83 80 144 139 217 350 325 405 328 455 822 830 550 735 1330

WT 101/4 101/4 101/4 16 16 16 23 23 23 23 36 36 34 36 36 59 59 59 59 68 68 122 CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones CFM Sones

0 103 2.0 151 2.5 186 3.4 124 1.1 138 1.4 215 2.3 254 0.8 266 1.3 318 1.6 412 2.8 447 2.2 545 3.1 766 2.6 737 3.2 813 3.8 908 1.9 3.5 4.2 5.8 6.4 6.0 6.4

PERFORMANCE IN INCHES WG .125 .25 .375 .5 .75 100 98 97 96 86 2.1 150 2.7 184 3.6 111 1.1 124 1.3 198 2.2 226 0.8 242 1.5 293 1.8 398 2.8 403 2.2 507 2.8 753 2.4 688 3.2 777 3.6 841 2.0 3.1 4.0 5.3 6.0 5.8 6.1 2.3 148 2.9 182 4.0 102 1.3 114 1.4 180 2.7 203 1.3 222 2.3 266 2.6 383 3.2 364 2.5 464 2.8 740 2.4 635 3.3 742 3.5 782 2.3 1013 3.1 1484 4.1 1543 5.4 1619 5.5 2045 5.2 3460 5.7 2.6 148 3.0 182 4.0 77 1.3 91 1.7 160 2.9 178 1.5 206 3.3 248 3.3 363 3.7 317 2.7 406 2.7 726 2.5 567 2.7 707 3.4 715 2.6 923 3.4 1440 4.2 1484 5.4 1464 5.3 1901 5.0 3280 5.4 122 3.0 145 1.9 188 3.4 230 4.0 340 4.7 217 2.7 325 3.1 703 2.6 475 2.5 672 3.5 631 2.9 832 3.4 1396 4.3 1427 5.1 1284 4.7 1702 4.6 3092 5.1 1294 4.6 1307 3.2 772 3.8 1114 3.4 2551 4.7 603 3.8 636 3.0 70 2.1 133 3.0 145 3.4 309 6.5 2.7 146 3.4 179 4.1 3.3 135 3.9 170 4.5

1378 1314 13 4
1

1112 1058 10 8
5

71516 1012 10 2
1

114 6 6 6 8 8 8 8 8 8 8 8 8 8 8 8 8 6 6 11

1014 12 12 12 12 8
7

314 914 9 4
1

1314 14 14 14 14 18 18 2358 18 18 2334 23 4


3

1058 11 8
7

1012 11 4
1

914 10 10 10 10 1314 13 4
1

1178 1178 11 8
7

1114 1114 11 4
1

1278 1278 12 8
7

1438 14 8
3

1412 14 2
1

1678 16 8
7

1158 1438 14 8
3

1158 1412 14 2
1

2258 1678 16 8
7

1012 1314 13 4
1

419 4.9

527 4.3

1438 14 8
3

1412 14 2
1

2258 22 8
5

1314 13 4
1

1182 1094 1584 1533 1672 1604 1842 1749 2249 2157 3778 3622

2334 2334 35 35 45 2
1

1438 1438 14 4
3

1412 1412 14 4
3

1834 1834 28 28 40

2258 2258 32 4
3

1314 1314 13 13 14 8
5

1182 5.0 1172 5.8

1434 16 2
1

1434 16 2
1

3234 43 4
1

1751 4.3

All dimensions in inches. Performance certified is for installation type D: Ducted inlet, Ducted outlet. Performance ratings include the effects of a backdraft damper. Speed (RPM) shown is nominal. Performance is based on actual speed of test. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) from the test inlet duct in a hemispherical free field calculated per AMCA Standard 301. Values are for installation type D: Ducted inlet fan sone levels. Ratings do not include the effects of duct end correction.

UL/cUL 507 E33599

Cabinet Fans are also UL Listed for above bathtub/shower with GFCI branch protected circuit. File No. E33599

Greenheck Fan Corporation certifies that the CSP models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

For complete product information refer to catalog Models SP and CSP, or contact your local representative.

CEiliNg, CAbiNET AND iNliNE FANS

43

Lighted Grilles & Grille Accessories

SP Grilles

Standard Designer (B50-B200, A50-A390) (White Plastic Finish) (With and without motion detector/time delay)

Decorative (optional on B50-B200, A50-A390) (White plastic finish) (With and without motion detector/time delay)

Lighted Grilles
PRISMATIC LENS
The prismatic lens design provides approximately 25% more light than a traditional frosted lens. The lens may be easily removed to replace light bulbs. (Patent Pending) Aluminum Grille (optional on B50-B200, A50-A390) (Standard on A410 and larger) (White enamel finish)

FROSTED LENS
The frosted lens option is a traditional design which lets approximately 80% of light through the lens. The lens may be easily removed to replace light bulbs.

COMPACT FLUORESCENT LAMPS (CFL)


Quick start bulbs (1 or 2) Patent pending Reflective light box Produces 90% less heat Lower energy costs Two 13 watt CFL bulbs equals 100 watts of incandescent light (included)

Stainless Steel (optional on B50-B200, A50-A390) (Polished stainless finish)

INCANDESCENT LAMPS
Dimmable Patent pending Reflective light box Low first-cost light One bulb provides up to 100 watts of light (by others)

44

CEiliNg, CAbiNET AND iNliNE FANS

Roof Discharge Accessories


RJ-4 and RJ-6x9
E D C

RJ-10x10
D C 10 (254) 11.125 (283)

3.5 (89)

A B

2.875 (73) 9.375 (238) 6.5 (165) B A 1.625 (42)

MODEL RJ Pitched Roof Cap


Steel construction with black enamel finish Integral flashing flange Built-in birdscreen and damper
MODEL RJ-4 RJ-6 x 9 RJ-10 x 10 FOR USE WITH SIZES C50, B50-B80 B90-B200 A50-A390 A410-A1050 A 11 1834 18 2
1


D E 412 612 9 2
1

3.375 (86)

B 914 1414 27 2
1

C 814 1412 15 4
3

THROAT 4 in. Dia. 6x9 10 x 10

5.125 (130)

11.5 (292)

5 516 10 38 23 8
5

MODEL EL - 10x3 Elbow Discharge with Grille


Designed for installation under roof eaves Painted steel louvered grille Built-in damper For SP/CSP sizes 50-290

All dimensions in inches.

Flat Roof Caps


B

CURB CAP
B

FLASHING FLANGE
B

B
C

Dia.

C
D Dia. A B MODEL GRS

C 13/4 in.

Dia. A

D Dia. A

11/2 in. A

MODEL RCC-7

Weathertight aluminum construction Integral birdscreen Built-in curb cap Requires roof curb

All aluminum exterior construction Galvanized steel C D internal supports Integral birdscreen Dia. Built-in curb cap A Requires roof curb
B 12 20 2
1

Weathertight aluminum construction Integral birdscreen Built-in flashing flange

MODEL RFC-7

MODEL GRSF

All aluminum exterior construction Galvanized steel internal supports Integral birdscreen Built-in flashing flange
C 10 614 778 834 914 D 6 8
3

MODEL RCC-7 GRS-10 GRS-12 GRS-16 GRS-20

FOR USE WITH SIZES 50-390 410-710 780-1050 1410-2150 3600

A 15 19 22 26 30

C 10 6 4
1

D 638 3 314 3 4
3

Dia. 7 10 4
1

MODEL RFC-7 GRSF-10 GRSF-12 GRSF-16 GRSF-20

FOR USE WITH SIZES 50-390 410-710 780-1050 1410-2150 3600

A 18 23 26 30 34

B 12 2012 2434 2858 35

Dia. 7 1014 1214 16516 20516

3 314 334 414

2434 28 8
5

758 8 4
3

1214 16 16
5

35

914

414

20516

All dimensions in inches.

All dimensions in inches.

HANGING VIBRATION ISOLATORS


Vibration isolator kits are available for suspended installations. Kits include all hardware necessary to mount one unit, with the exception of 10-32 threaded rod to be supplied by others. Fan mounting brackets include prepunched mounting holes for ease of installation.
UNIT SIZE B50-B200 A50-A190 A200-A390 A410, A510 A710, A780 A700 A900-A1050 A1410-A1550 A1750, A2150 A3600 A 4 2
1

B 1558 1458 1512 1958 2518 2538 3634 4858

512 6 4
3

10-32 hanging support rod by others

914 512 9 4
1

914 9 4
1

All dimensions in inches.


CEiliNg, CAbiNET AND iNliNE FANS

45

Wall Discharge Accessories


MODEL WC
B

(Round Connection) Hooded Wall Cap

MODEL WC

Aluminum construction - aluminum finish For outside wall applications Built-in birdscreen (not available on WC-4) and damper
MODEL WC-4 WC-6 WC-8 FOR USE WITH SIZES C50, B50-B80 B90-B200 A50-A190 A200-A510 A 612 8 11

(Square/Rectangular Connections) Hooded Wall Cap


E

D B
E

E
B 6 8 11 C 4 6 8 D 234 418 518 E 5 5 312

Steel construction with black enamel finish For outside wall applications Built-in birdscreen and damper
MODEL WC-10 x 3 WC-8 x 8 WC-18 x 8

C A

FOR USE WITH SIZES 50-290 200-510 700-1550

A 5 2
1

B 12 4
3

C 3 2
1

D 10 4
1

E 11 8
1

F 4 4
1

G 5 5 5

1014 1014

1014 2014

814 814

814 1814

814 1814

634 634

All dimensions in inches.

All dimensions in inches.

MODEL WL Wall

Anodized aluminum grille E Built-in damper Not recommended for exterior D applications A exposed to severe weather conditions. An external wall louver is recommended for such applications.
MODEL WL-10 x 3 WL-18 x 6 FOR USE WITH SIZES 50-290 390-1550 A 12 19 34 B 5 4
1

Louvered Discharge

MODEL BVE
Brick Vent
Designed for installation in masonry walls Anodized aluminum construction Built-in aluminum mesh insect screen
MODEL FOR USE WITH SIZES 50-290 390-510 700-1050 A 8 18 12 15 58 B 7 34 7 4
3

C 4 4 4

C 10 18

D 7 4
3

E 3 2
1

BVE808 BVE128 BVE157

7 34

All dimensions in inches.

All dimensions in inches.

ACCESSORy PRESSURE DROPS

MODEL RDC Round Duct Connector


Replaces the standard square discharge ductconnector and damper. Uses existing mounting holes Galvanized steel construction RDC 6 includes a damper RDC 8 does not include a damper
RDC-6
MODEL RDC-6 RDC-8 FOR USE WITH SIZES A110-A190 A200-A510 DIA. 6 8

The chart below can be used with all of the discharge accessories shown on these two pages. Specific pressure drop values for these accessories must be included in total system calculations for proper fan selection.
30

RDC-6

20
WL-18x6 RJ-10x10

RDC-8

10

CFM x 100

9 8 7 6 5 4 3

BVE-157 WC-18x8

BVE-128 WC-8x8 WC-8


WC-10x3 WC-6 RJ-6x9 EL-10x3 WL-10x3 BVE-808 RFC-7 RCC-7

All dimensions in inches.

MODEL TR 6x4

Transition Duct Reducer


FOR USE WITH SIZES B50-B200 TR 6 x 4 A50-A90 A110-A190*
*Used in conjunction with RDC-6.

Reduces duct from 6 to 4 inches. Galvanized steel construction


MODEL

.01 1

.02

.03

.04 .05 .06 .07 .08 .09.10

.2

.3

.4

.5

.6

Above accessories tested with 4 feet of inlet duct

Pressure Drop in Inches of Water Gauge

46

All dimensions in inches.


CEiliNg, CAbiNET AND iNliNE FANS

Accessories
MOTION DETECTORS
Motion detectors may be used with Models SP and CSP fans, or fan and light combinations. Motion detectors use a passive infrared motion detector that will automatically turn on the fan when a change in temperature is sensed. They have a viewing area of 180 degrees, however they must be placed in the line-of-sight. They also have an adjustable time delay shutoff setting HOT of 1 to 20 minutes. BLACK Model MDW - For use on fan or lights. GREEN Available shipped loose. GND. Rated for 115V UL/cUL Listed RED Requires 2 x 4 handy box
LOAD (12.5 AMPS MAX) NEUTRAL

TRANSFORMERS
Transformers are available for applications requiring voltage reduction. Selection is based on motor amperage. All transformers are shipped loose. Model T-2.0 - UL/cUL Listed Rated for 230/277 to 115, 2 Amps Model T-4.3 - UL/cUL Listed Rated for 230/277 to 115, 4.3 Amps Model T-6.5 - UL/cUL Listed Rated for 230/277 to 115, 6.5 Amps Model T-8.6 - UL/cUL Listed Rated for 230/277 to 115, 8.6 Amps
BLK BLK BLK

277 V SUPPLY SWITCH BOX H1 X1 H2 X2 H3 SWITCH


277V TO 115V TRANS. 750 VA RED RED

115 V MOTOR

CEILING RADIATION DAMPERS


The Greenheck SP-A and SP-B ceiling radiation dampers are UL/cUL Classified, rated at three to four hours fire resistance, and are available on all SP-A and SP-B fans and fan/light combinations. This design saves space by allowing the dampers to be mounted directly beneath the fan.

SP MODEL A50 - A190 B50 - B200 A200 - A390 A410 - A510 A710 - A780 A-700 A900 - A1550

CRD 310 320 350 700 360

LENGTH 1312 1438 18716 24 16


3

WIDTH 1118 1214 141516 12 4


1

HEIGHT 3 3 3 3 3

24316

141516

FILTERS

All dimensions in inches.

Resistance in w.c.

Fans used in most applications, even where air is not excessively dirty, will collect airborne dirt on wheels and motors over time. Accumulations of dirt on the fan wheel will sharply reduce performance and cause imbalance. Dirt buildup on the motor can cause it to overheat. All of these conditions will shorten the life of the fan. To help reduce this accumulation, washable aluminum mesh filters are available to trap dirt before it enters the fan. These filters should be regularly cleaned to maintain performance. Fig. A (Filter Loss Chart) shows the effect the filter will have on performance. To determine the added resistance, divide the desired cfm by the filter area (ft2). This will give FPM. Use this with the filter loss chart to get the added resistance. In addition to reducing dirt accumulations on the motor and wheel, filters also reduce sound levels.

.24 .22 .20 .18 .16 .14 .12 .10 .08 .06 .04

Filter loss Chart

Mesh Filter SP Grille

SP MODEL SP-A50 - A190 SP-B50 - B200, A200 - A390 SP-A410 - A510 SP-A710 - A780 SP-A900 - A1550

DESIGNER GRILLE F-200 F-200 NA NA

FILTER MODEL F-210 F-220 F-250 F-260

FILTER AREA (FT2) 0.739 0.911 1.518 2.078

.02

Fig. a

.00

3 4 5 6 Velocity FPM x 100

CEiliNg, CAbiNET AND iNliNE FANS

47

Cabinet Exhaust Belt Drive - BCF


Model BCF cabinet fans are belt drive and are designed for low sound levels in supply, exhaust or ducted return applications. Designed in a low-profile cabinet with heights ranging from 11 in. to 23 in. Fan wheels are galvanized steel, forward-curved, centrifugal type.

SERVICE CHART
BCF-106 through 212

5 DAY

10 DAY

PERFORMANCE STANDARD CONSTRUCTION FEATURES


Galvanized steel housing Hinged access panel on sizes 106, 206, 107, 207 and bolted access panels on all larger sizes Motor and drive frame isolated on shock mounts Inlet and outlet duct connection flanges Ball bearing motors Fan shafts mounted in ball bearing pillow blocks Adjustable motor pulley Static-resistant belts Corrosion-resistant fasteners

OPTIONS AND ACCESSORIES


Upblast discharge Fiberglass insulation Filter boxes and filters Mixing box Slide out filter box Side access doors Isolators UL/cUL 705 Electrical Dual drives Greenheck coatings (See coatings page 119)
note: see pages 54-55 for detailed accessory information
B

Performance capabilities range from 170 cfm to 3,330 cfm for single-fan models and 620 cfm to 5,875 cfm for double-fan models and up to 1.5 in. wg of static pressure.

F C

1 in. E A

BCF STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL BCF-106 BCF-107 BCF-108 BCF-110 BCF-112 BCF-206 BCF-207 BCF-208 BCF-210 BCF-212 A 20 23 26 32 36 34 38 44 48 58 B 2314 29 32 36 42 2314 29 32 36 42 C 11 13 16 19 23 11 13 16 19 23 E 12 15 18 24 28 26 30 36 40 50 F 6 8 10 12 14 6 8 10 12 14 CFM 170 490 770 360 1080 1260 650 1450 1850 860 2000 2260 930 2530 3330 600 980 1300 760 1805 2260 1150 2700 3450 1660 3940 4410 2050 5110 5850 .125 743 1391 2086 596 1419 1642 537 964 1200 490 950 1066 413 887 1146 983 1397 1783 623 1202 1474 541 982 1222 501 975 1078 438 919 1043 PERFORMANCE IN INCHES WG .25 .5 .75 1 988 1499 1721 1923 2113 2153 726 1468 1561 1654 1744 1683 660 868 1022 1141 1259 1370 1247 1339 593 755 984 1070 1169 1262 1092 1163 1248 495 639 764 927 1004 1076 1144 1176 1237 1294 1152 1424 1525 1754 1942 2110 1877 742 1266 1385 1498 1600 1527 669 1048 1180 1299 1411 1274 1379 590 756 1029 1120 1203 1280 1128 1215 1291 515 642 765 954 1021 1085 1151 1073 1133 1189 1.5 2468 1915 1578 1426 1266 2427 1803 1619 1429 1271

All dimensions in inches. Performance certified is for installation type D: Ducted inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Greenheck Fan Corporation certifies that the BCF fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 E40001 - BCF with TEFC motors

For complete product information refer to catalog Model BCF, or contact your local representative.

48

CEiliNg, CAbiNET AND iNliNE FANS

Ceiling Exhaust Belt Drive - BDF


Model BDF are belt drive duct fans. These fans are designed for low sound levels in supply, exhaust or ducted return applications. Forward-curved wheels provide high efficiency with low sound levels.

SERVICE CHART
BDF - All models and sizes

3 DAY

10 DAY

PERFORMANCE
A B C 2 in. E D INLET OPENING

Performance capabilities range from 400 cfm to 17,000 cfm and up to 2.5 in. wg of static pressure.

H W DAMPER OUTLET OPENING

1 in.

STANDARD CONSTRUCTION FEATURES


Galvanized steel housing and forward-curved wheel Side access panels Motor and drive frame isolated on shock mounts Inlet and outlet duct connection flanges Ball bearing motors Fan shafts mounted in ball bearings Adjustable motor pulley Fan shaft pulley Static-resistant belts

OPTIONS AND ACCESSORIES


UL/cUL 705 Electrical Insulation Filter boxes Gravity and motorized dampers External isolators Dual drives Greenheck coatings (See coatings page 119) Top horizontal mounting arrangement
note: see pages 54-55 for detailed accessory information

BDF STANDARD PERFORMANCE & DIMENSIONAL DATA


MODEL
BDF-80 BDF-90 BDF-100 BDF-120 BDF-150 BDF-180 BDF-200

A
2314 2414 2614 33 3434 4014 5014

B
1812 2114 2234 2714 3258 4134 4914

C
1578 1834 2034 2234 2734 3134 3934

DAMPER OUTLET OPENING (WxH)


934 x 878 121/4 x 101/2 1334 x 1178 16 x 1338 1918 x 1638 221/2 x 1878 2318 x 2514

INLET MIN/MAX SONES OPENING (DxE) CFM @ 0.25 in.


15316 x 121116 181/4 x 1578 1934 x 1778 2418 x 1978 2858 x 2378 371/2 x 2778 4518 x 36 300 1300 800 2500 800 2800 1000 4000 2500 5800 4000 9400 5000 15000 4.7 14.0 4.1 17.4 4.8 16.4 3.7 18.6 7.0 24 7.6 24 12.5 35

280 1211 334 1042 255 893 198 792 328 761 251 591 222 666

PERFORMANCE IN INCHES WG 0 .25 .75 1.25 1.75


1351 584 1112 501 933 802 406 797 353 632 310 697

1298 1080 917 876 529 722 464 756

1464 1243 1057 931 806 814

1624 1394 1187 1009 893 871

All dimensions in inches. Performance certified is for installation type D: Ducted inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) from the test inlet duct in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type D: ducted inlet, ducted outlet. Ratings do not include the effects of duct end correction.

For complete product information refer to catalog Model BDF, or contact your local representative.

Greenheck Fan Corporation certifies that the BDF fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

BDF Model is listed for Electrical (UL/cUL 705 with TEFC motor only. File no. E40001.)

CEiliNg, CAbiNET AND iNliNE FANS

49

Inline Direct Drive and Belt Drive - SQ/BSQ


Models SQ and BSQ are the ideal selection for clean air applications (intake, exhaust, return, or make-up air systems) where space is a prime consideration. Fan wheels are centrifugal, backward-inclined, and constructed of aluminum. Model SQ centrifugal inline fans are direct drive. Maximum operating temperature is 130F Model BSQ centrifugal inline fans are belt drive. Maximum operating temperature is 180F.

SQ
1 in. A 1 in. B sq.

PERFORMANCE
SQ performance capabilities range from 80 cfm to 5,025 cfm and up to 1.75 in. wg of static pressure. BSQ performance capabilities range from 62 cfm to 26,600 cfm and up to 3.5 in. wg of static pressure.

B sq. C sq. C sq.

BSQ
A

C sq.

B sq. C sq.

D*

* May vary depending on motor size.

SQ STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL
SQ-60 SQ-65 SQ-70 SQ-75 SQ-80 SQ-85 SQ-90 SQ-95 SQ-100 SQ-120 SQ-130 SQ-140 SQ-160

n Performance for available in stock sizes is shown on page 52

A
13 13 13 13 16 16 16 16 21 21 21 22 26

B
12 12 12 12 15 15 15 15 17 19 21 23 26

C
8 8
7

DAMPER SIZE

IN STOCK SIZES (n)

MIN/MAX SONES RPM @ 0 in.


1050 1550 1050 1550 1050 1550 1050 1550 1050 1550 1050 1550 1050 1550 1050 1550 860 1725 860 1725 860 1725 860 1725 860 1725 1.7 4.0 2.1 4.2 2.7 5.6 3.6 6.1 3.8 7.3 4.0 7.6 4.0 7.6 4.9 9.6 4.7 13.1 4.4 14.7 6.2 17.4 7.0 20 8.8 26

PERFORMANCE IN INCHES WG 0
126 186 154 228 212 313 241 356 306 451 357 528 500 738 623 919 725 1454 971 1948 1180 2368 1637 3283 2506 5027

.125
145 79 184 118 252 146 294 225 394 272 474 369 654 475 829 611 1402 843 1883 1048 2307 1487 3211 2334 4941

.25
105 128 189 229 104 342 142 413 188 564 274 720 410 1349 704 1818 890 2247 1316 3139 2147 4856

.5

.75

1.25

1.75

878 878 878 1178 1178 1178 1178 1378 1578 1778 1978 2278

9x9 n n 12 x 12 n n n 14 x 14 16 x 16 18 x 18 20 x 20 23 x 23 n n n

201 254 334 461 1227 1692 2105 2985 1605 4683 1077 1562 1961 2825 4504 830 1416 1791 2645 4312 1239 1559 2424 4094 1624 3575

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information refer to catalog Models SQ and BSQ or contact your local representative.

Greenheck Fan Corporation certifies that the SQ and BSQ fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 E40001 - SQ/BSQ

50

CEiliNg, CAbiNET AND iNliNE FANS

Inline Direct Drive and Belt Drive - SQ/BSQ


SERVICE CHART
All SQ Models and Sizes SQ-75 through 100, 120 & 140 BSQ-70 through 180 & 240 BSQ-200, 300 through 420 BSQ-HP 130HP through 300HP All BSQ-HP Sizes

IN NEXT 3 5 10 STOCK DAY DAY DAY DAY


SQ
n n n n n n n n n n n n n

BSQ
n n n n n n n n n n n n n n

OPTIONS AND ACCESSORIES


Motor covers-standard and insulated Aluminum construction (5-Day) Inlet and outlet guards Filter boxes and filters (3, 5 & 10 Day) Insulated fan housing Gravity and motorized dampers (stock) Isolators (stock) Aluminum rub ring UL/cUL 705 Electrical Relubricatable bearings (Belt drive) Dual drives NEMA-3R and ExP disconnect switches Greenheck coatings (See coatings section of this catalog) Side discharge

STANDARD CONSTRUCTION FEATURES


Galvanized steel housing Non-overloading backwardinclined aluminum wheel Side access panels Inlet and outlet duct connection flanges Ball bearing motors Adjustable motor pulley Adjustable motor plate Fan shaft mounted in ball bearing pillow blocks Static-resistant belts Corrosion-resistant fasteners

BSQ STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA


MODEL
BSQ-70 BSQ-80 BSQ-90 BSQ-100 BSQ-120 BSQ-130 BSQ-140 BSQ-160 BSQ-180 BSQ-200 BSQ-240 BSQ-300 BSQ-360 BSQ-420

note: see pages 54-55 for detailed accessory information


n Performance for available in stock sizes is shown on page 53 107 521 239 1065 353 1579 528 2066 758 2779 914 3111 1341 4009 1470 5713 2153 6656 1609 7313 3271 11972 6176 17693 7524 22967 12424 27237

A
21 21 21 21 21 21 22 26 28 32 34 38 42 50

B
15 15 15 17 19 21 23 26 28 32 39 46 52 58

C
1178 1178 1178 1378 1578 1778 1978 2278 2378 2778 3478 41 8
7

D*
1212 1212 1212 1212 1212 1212 1212 1338 1334 16 19 18 18 18

DAMPER SIZES
12 x 12

IN STOCK SIZES (n)


n n n

MIN/MAX RPM
790 2486 790 2645 790 2691 790 2556 790 2490 790 2355 790 2135 590 2001 590 1645 390 1375 390 1225 375 967 300 811 325 670

SONES @ .125 in.


6.0 25 6.0 28 6.0 28 6.0 26 6.5 31 6.9 30 6.1 30 6.1 40 9.9 29 10.0 27 8.6 41 9.6 33 10.1 33 7.6 39

.125

PERFORMANCE IN INCHES WG .25 .5 .75 1.25


504 1041 1549 2029 590 2736 676 3074 1160 3958 1101 5648 1777 6565 7191 2342 11801 5271 17396 6149 22607 11253 26778 468 994 1488 1956 2650 2970 3856 5519 6376 6947 11460 16776 21888 7320 25749 426 944 1420 1882 2563 2876 3741 5390 6178 6677 11070 16124 21011 24660 334 834 1271 1734 2386 2659 3494 5103 5744 6076 10245 14888 19146 22322

2.25

534 866

14 x 14 16 x 16 18 x 18 20 x 20 23 x 23 24 x 24 28 x 28 35 x 35 42 x 42 48 x 48 54 x 54

n n n n n n

1984 1988 2861 4392 4450

8149 11047 14128

4778 5378

*May vary with motor size. All dimensions in inches.

BSQ HIGH PRESSURE PERFORMANCE & DIMENSIONAL DATA


MODEL
BSQ-130HP BSQ-140HP BSQ-160HP BSQ-180HP BSQ-200HP BSQ-240HP BSQ-300HP BSQ-360HP

A
21 22 26 28 32 34 38 42

B
21 23 26 28 32 39 46 52

C
1778 1978 2278 2378 2778 3478 4178 4778

D*
1212 1212 1338 1334 16 19 18 18

DAMPER SIZE
18 x 18 20 x 20 23 x 23 24 x 24 28 x 28 35 x 35 42 x 42 48 x 48

MIN/MAX RPM
790 2770 790 2641 690 2321 590 1913 390 1602 400 1605 400 1196 300 1026

SONES @ .75 in.


6.2 28 6.7 33 5.4 34 7.3 32 9.4 26 9.5 42 10.3 30 13.8 34

513 2184 785 3061 1203 4614 1433 5273 984 6025 2142 10464 3869 12856 3869 15458

.15

392 2162 654 6036 1029 4582 1220 5243 5968 1599 10397 3455 12751 3205 15320

.25

PERFORMANCE IN INCHES WG .75 1.25 2 2.5


2056 2907 4411 5050 5659 10066 12228 14631 1950 2768 4234 4816 5291 9675 11681 13957 1750 2512 2918 4396 4669 9007 10677 12806 1608 2319 3660 4058 4089 8512 9853 11838

3
1421 2088 3351 3620 2894 7987 8840 10796

3.5
1110 1759 3001 3006

7348 7545 8982

*May vary with motor size. All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

CEiliNg, CAbiNET AND iNliNE FANS

51

Inline Direct Drive and Belt Drive - SQ/BSQ


SQ PERFORMANCE DATA - IN STOCK
MODEL HP
1

stock Model sQ fans include disconnect switch. sizes 100 and above also include a motor cover and UL/cUL 705. MAX BHP 0.011 0.210 0.035 0.016 0.032 0.055 0.017 0.033 0.057 0.020 0.040 0.068 0.031 0.059 0.100 0.25 0.48 0.30 0 241 298 356 306 378 451 357 442 528 500 619 738 623 771 919 1455 1948 2107 .125 146 224 294 225 312 394 272 377 474 369 519 654 475 659 829 1403 1884 2061 133 229 104 244 342 142 298 413 188 397 564 274 522 720 1350 1819 1942 352 603 1292 1754 1818 461 1227 1692 1666 276 1156 1625 1447 1078 1563 1121 831 1417 1240 245 457 334 185 343 254 140 280 201 137 PERFORMANCE IN INCHES WG .25 .375 .5 .625 .75 1 1.25

RPM 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1050 1300 1550 1725 1725 1140

TS 2233 2765 3297 2989 3701 4412 2989 3701 4412 2989 3701 4412 2989 3701 4412 5052 5927 4346

SONES @ 0 IN. 3.6 4.1 6.1 3.8 5.4 7.3 4.0 5.5 7.6 4.0 5.4 7.6 4.9 7.6 9.6 13.1 14.7 10.8

90 45 25 50 30 15

SQ-75-DGEX-QD 3-Speed

1 1 1

SQ-80-DGEX-QD 3-Speed

1 1 1

140 30 15 50 25 10 30 15 8 4 2 3

SQ-85-DGEX-QD 3-Speed

1 1 1

SQ-90-DGEX-QD 3-Speed

1 1 1

SQ-95-DGEX-QD 3-Speed SQ-100-AX-QD SQ-120-AX-QD SQ-140-BX-QD

1 1 1 1

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

SQ & BSQ OPTIONS AND ACCESSORIES


Hanging Vibration Isolator Model HVI (Hanger rods supplied by others) Backdraft Damper Model WD-330

Side Discharge
The side discharge option provides several advantages, from removing a system effect problem, increasing performance, or even reducing installation labor. The most notable is reducing system effects. Notice Fig. 1 how the air, when discharged into the corner, will take several duct lengths before becoming smooth again. This is not the case with a side discharge. Notice now in Fig. 2 as air comes into the fan/corner and leaves the fan/corner you have nice smooth airflow providing a more predictable system. (Remember the duct length prior to or following the installation location should be approximately two to three wheel diameters to achieve catalogperformance).
Fan

Housing Insulation Kit

Base Vibration Isolator Model BVI

Fig. 2 Fan

Fig. 1

52

CEiliNg, CAbiNET AND iNliNE FANS

Inline Direct Drive and Belt Drive - SQ/BSQ


BSQ PERFORMANCE DATA - IN STOCK
Stock Model BSQ fans include disconnect switch, motor cover UL/cUL 705.

MODEL BSQ-70-4X-QD 1368-1970 RPM 1/4 HP, 115/60/1 ODP BSQ-80-4X-QD 1222-1835 RPM 1/4 HP, 115/60/1, ODP BSQ-80-LMDX-QD 1050-2485 RPM BSQ-90-4X-QD 1168-1690 RPM 1/4 HP, 115/60/1 ODP BSQ-90-LMDX-QD 1050-2690 RPM

HP
1

RPM 1370 1730 1970 1050 1835 1885 2100 2645 1050 1360 1695 1750 1910 2220 2690 1050 1265 1610 1765 2030 2325 2555 1000 1370 1500 1725 1974 2170 2490 900 1293 1424 1630 1866 2053 2355 800 1075 1180 1355 1550 1710 1960 2135 650 860 960 1100 1265 1390 1590 1750 2000 700 790 905 1035 1140 1310 1440 1645 500 570 650 715 820 900 1035 1225

4 4

1 1

3 1 2 3 4
1

SONES @ 0 IN. 11.8 16.1 19.1 8.0 17.2 17.7 21 28 8.0 11.7 16.0 16.5 18.1 22 28 7.9 9.8 15.0 16.3 19.7 23 26 7.7 11.0 12.4 15.2 19.7 23 31 7.7 11.9 13.7 16.2 21 25 35 6.3 10.7 12.0 14.2 16.2 18.3 24 30 6.6 8.7 9.8 12.3 15.6 18.0 22 28 40 10.0 10.6 12.2 14.5 16.5 20 23 29 10.7 12.3 14.3 16.1 19.4 22 28 41

MAX BHP 0.088 0.18 0.26 0.049 0.26 0.28 0.39 0.79 0.061 0.14 0.26 0.29 0.37 0.59 1.05 0.073 0.13 0.26 0.34 0.52 0.79 1.05 0.102 0.26 0.34 0.52 0.785 1.05 1.57 0.087 0.26 0.35 0.52 0.78 1.05 1.58 0.11 0.26 0.35 0.52 0.78 1.05 1.58 2.04 0.11 0.25 0.35 0.52 0.79 1.05 1.57 2.08 3.07 0.24 0.35 0.52 0.78 1.04 1.58 2.07 3.14 0.35 0.53 0.78 1.04 1.56 2.07 3.15 5.22

.125 265 349 404 372 721 742 834 1065 547 753 966 1000 1100 1291 1578 774 966 1266 1398 1623 1872 2065 1026 1475 1629 1893 2183 2410 2779 1084 1652 1838 2126 2448 2702 3112 1362 1925 2132 2474 2852 3161 3640 3975 1671 2333 2637 3058 3550 3920 4509 4979 5710 2649 3046 3546 4101 4545 5259 5803 6656 4518 5279 6121 6795 7874 8689 10058 11973

.25 227 323 383 298 688 710 805 1041 443 684 915 951 1057 1255 1548 671 893 1207 1345 1577 1832 2028 914 1396 1557 1831 2129 2361 2737 911 1563 1754 2050 2389 2655 3074 1185 1808 2029 2390 2781 3096 3584 3923 1391 2165 2497 2941 3448 3827 4428 4905 5645 2387 2840 3366 3947 4408 5145 5699 6566 4001 4845 5757 6476 7616 8457 9856 11802

.375 186 293 358 184 651 675 775 1018 290 605 859 898 1009 1216 1519 498 798 1149 1292 1531 1791 1991 783 1315 1484 1768 2075 2312 2694 635 1462 1672 1983 2324 2592 3026 860 1679 1916 2295 2702 3030 3528 3872 1966 2331 2808 3346 3734 4347 4831 5581 2023 2569 3167 3789 4265 5021 5590 6475 3325 4363 5360 6133 7317 8198 9653 11631

PERFORMANCE IN INCHES WG .5 .625 .75 1 140 90 260 227 192 112 330 301 272 211 614 640 743 995 509 798 841 958 1175 1487 683 1089 1240 1484 1750 1954 1230 1410 1705 2020 2262 2651 1328 1568 1908 2266 2357 2971 1535 1795 2195 2619 2955 3469 3821 1691 2142 2662 3226 3638 4266 4757 5516 2210 2928 3606 4122 4896 5476 6377 3704 4933 5757 7016 7926 9420 11460 571 598 711 970 383 730 776 904 1132 1453 525 555 674 945 426 459 595 894

1.25

1.5

1.75

141

297 508 835

367 773 705

3 1 2 3 4
1

1 BSQ-100-4X-QD 1073-1610 RPM 1/4 HP, 115/60/1 ODP BSQ-100-LMDX-QD 1050-2555 RPM
1

655 708 845 1086 1419

439 528 705 987 1347

517 879 1270

733 1185

540 1097

3 1 2 3 4
1

1 BSQ-120-4X-QD 923-1370 RPM 1/4 HP, 115/60/1 ODP BSQ-120-LMDX-QD 1000-2490 RPM
1 1

1004 1179 1439 1710 1917 1136 1331 1641 1964 2212 2607 1170 1443 1820 2202 2484 2923 1307 1651 2092 2532 2880 3404 3763

917 1101 1396 1669 1880 1026 1243 1572 1908 2161 2563 958 1299 1714 2128 2426 2877

924 1263 1593 1809

1120 1474 1732

1360 1624

1201 1521

3 1 2 3 4
1 112
1 1

1010 1425 1791 2059 2475

1243 1663 1951 2387

1518 1833 2294

1307 1709 2198

BSQ-130-LMDX-QD 900-2355 RPM

3 1 2 3 4
1 112
1 1

1468 1949 2286 2777

1121 1740 2117 2659

1462 1926 2514

1686 2359

BSQ-140-LMDX-QD 800-2135 RPM

3 2 3 4
1

1 112 2
1 1

1442 1977 2442 2800 3338 3703

1631 2246 2638 3201 3583

1955 2453 3059 3454

1429 2181 2904 3324

1758 2718 3181

BSQ-160-LMDX-QD 650-2000 RPM

3 1 2 3 4
1 112 2 3
1 1

1883 2500 3101 3525 4184 4683 5451 1499 2621 3398 3944 4772 5363 6278

2296 2961 3412 4086 4610 5387

2629 3157 3887 4431 5256

2101 2830 3664 4247 5100

2334 3397 4044 4943

3065 3810 4770

BSQ-180-LMDX-QD 700-1645 RPM

2 3 4
1 112 2 3
1 3

2175 3166 3755 4630 5250 6179

2411 3283 4302 4979 5981

2510 3911 4678 5744

3365 4318 5485

3838 5216

2 4

BSQ-240-LMDX-QD 500-1225 RPM

1 112 2 3 5

4375 5358 6688 7646 9184 11270

4847 6349 7347 8947 11070

5494 6713 8433 10671

5833 7894 10245

7234 9804

6302 9345

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

CEiliNg, CAbiNET AND iNliNE FANS

53

Inline Fans Options & Accessories


HORIZONTAL MOUNTING
For ease of installation knockouts are provided at each location where mountingnel Pa brackets are shown in diagram below. Universally adjustable brackets are available to mount the fan in hanging or base mounted positions.
ce Ac s s

HANGING ISOLATORS - Complete hanging isolator kits are available with either neoprene or spring isolators. The isolators are sized to match the weight of the fan. (Hanging rods supplied by others).

s es cc el A n Pa

HANGING NEOPRENE

HANGING SPRING

BASE ISOLATORS - Complete base isolator kits are available with either neoprene or spring isolators and are sized to match the weight of the fan.

STANDING NEOPRENE

STANDING SPRING

MULTI DISCHARGE POSITIONS


BDF fans have been designed for horizontal mounting and are standard with a Bottom Horizontal Discharge. Optional Top Horizontal Discharge is also available. BCF fans are available with either Top Horizontal or Upblast Discharge positions. SQ and BSQ fans are available with Right Side Discharge, Left Side Discharge, Inline Discharge positions, or a combination of Right, Left, and Inline positions. BDF Discharge Positions Bottom Horizontal Top Horizontal BCF Discharge Positions Top Horizontal Upblast

Right Side

Left Side

SQ/BSQ Discharge Positions Inline

Combination

54

CEiliNg, CAbiNET AND iNliNE FANS

Inline Fans Options & Accessories - BDF, BCF, SQ & BSQ


FILTER BOx
Filter boxes incorporate a vee bank design constructed of galvanized steel. Filters are available in 1 in. or 2 in. throwaway (pleated) or permanent (washable aluminum mesh). Side access panels are standard for easy maintenance.
K*
ox rB lte ess Fi cc l A ane P

2 in.
n Fa ess cc nel A a P

BCF MODEL
SINGLE- DOUBLEFAN FAN

FILTER SIZE K* 4512 52 56 61 65

NO. FILTERS

SINGLE- DOUBLE- SINGLE- DOUBLEFAN FAN FAN FAN

BSQ MODEL 70 - 80 - 90 100 120 130 - 130HP 140 - 140HP 160 - 160HP 180 - 180HP NO. FILTERS 1 1 2 2 2 2 4 200 - 200HP 240 - 240HP 300 - 300HP 360 - 360HP 420 K* 5058 4714 52316 4638 5238 5138 55116 661116 68 8
7

MODEL 60-75 80-95 100 120 130 140 160

K* 2218 4558 4714 52316 4638 5238 5138

SQ FILTER SIZE 10 x 12 14 x 25 16 x 20 16 x 25 20 x 20 20 x 25 20 x 20

7218 7914 9318

FILTER NO. SIZE FILTERS 14 x 25 1 16 x 20 2 16 x 25 2 20 x 20 2 20 x 25 2 20 x 20 4 20 x 25 4 12 x 25 3 16 x 25 3 20 x 25 4 16 x 25 4 20 x 25 8 16 x 25 10 20 x 25 5 16 x 25 5 20 x 25 10

106 107 108 110 112

206 207 208 210 212

16x20 16x20 16x20 20x20 16x20 BDF

20x20 16x20 16x20 20x20 20x25

1 1 2 2 4

1 2 4 4 4

MODEL
80 90 100 120 150 180 200

K*
4934 54 8
7

FILTER SIZE
16 x 20 20 x 25 20 x 20 12 x 25 16 x 20 20 x 25 16 x 25

NO. FILTERS
2 2 2 4 8 6 12

5178 63916 62116 75 8


3

8514

K* is length of fan and filter box combined. All dimensions in inches.

INSULATED HOUSINGS
The interior of the fan housings and filter boxes can be lined with a fiberglass duct liner for noise reduction and condensation control. The duct liner can be utilized to reduce radiated noise from inline fan housings. It is recommended for applications when fans are placed in acoustically sensitive locations. The duct liner also reduces the noise radiating from the inlet and outlet of the fan.

CEiliNg, CAbiNET AND iNliNE FANS

55

Centrifugal Belt Drive - TCB


Model TCB centrifugal inline fans are the ideal choice for installations with straight-through airflow in ducted systems. The centrifugal wheels used in this design provide higher efficiencies and lower sound levels than axial type inline fans when used in medium pressure ducted systems. These fans can be mounted in any position from horizontal to vertical, allowing installation in the smallest possible space at the lowest installation cost. Also available in roof supply and roof exhaust configurations.

SERVICE CHART
TCB - All sizes

D Max. W/Motor Cover

10 DAY

H C

PERFORMANCE
Performance capabilities range from 360 cfm to 24,000 cfm and up to 4.5in. wg of static pressure.

STANDARD CONSTRUCTION FEATURES


AMCA Certified for Sound and Air Performance AMCA Type B spark resistance Backward-inclined aluminum wheel Aluminum rub ring Permatector coating Continuously welded steel housing Heavy duty, self-aligning pillow block bearings Inlet and outlet flanges with mounting holes Extended lube lines

OPTIONS AND ACCESSORIES


All aluminum construction Belt guard Companion flanges Dual drives Easy access door Inspection door - bolted or hinged Isolators Inlet and outlet guards
1260 1883 1686 2590 1253 1717 1631 2883 1158 1887 1315 1887 1020 1729 1207 1670 803 1600 970 1553 724 1244 858 1392 944 706 1069 537 946 623 915 705 528 804 379 604 468 665

Motor cover UL/cUL-705 (Electrical) UL-762 (Kitchen grease exhaust) Mounting rails Greenheck coatings (See coatings page 119)

TCB PERFORMANCE & DIMENSIONAL DATA


MODEL
TCB-9

D*

LEVEL
1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2 1 2

CFM
360 840 560 1040 480 960 700 1500 700 1600 900 1650 600 1800 1200 2000 1000 3750 1800 3600 1500 4200 2100 4200 1600 4400 3000 5500 2500 7500 4900 8400 3750 9750 5600 10400 5600 12800 9600 15600

SONES @ .125 in.


5.3 11.0 8.6 18.0 4.9 9.7 8.3 18.4 6.2 13.4 5.8 13.6 4.1 11.2 5.6 12.8 3.7 18.5 6.7 16.4 4.3 14.6 10.1 19.9 3.2 10.9 7.7 16.5 3.3 19.1 10.2 20 4.4 15.0 8.1 18.5 5.4 19.1 12.9 19.0

23 215/8 131/4 213/4 175/8 193/4

TCB-10

23 215/8 11

11 175/8 193/4

TCB-12

23 215/8 11

11 175/8 193/4

TCB-13 241/2 235/8 1378 231/4

19

213/4

TCB-16 281/2 275/8 1618

26

213/4 253/4

TCB-18

31 335/8 1838 291/4 261/4

32

TCB-22 351/2 395/8 2212 3334 301/2

38

TCB-24

42

453/4 245/8 3714 347/8 443/16

TCB-30 481/2 523/4 291/2 423/4

42

503/4

TCB-36

54

591/4 313/4 471/4 463/4 571/4

846 1689 1379 2431 858 1442 1359 2754 854 1729 1009 1715 661 1553 964 1510 507 1491 777 1456 486 1140 696 1302 388 831 574 987 356 865 520 849 294 629 427 746 274 545 397 620

.125

1000 1753 1480 2483 1012 1542 1454 2798 958 1782 1120 1768 793 1613 1049 1565 613 1530 843 1487 568 1176 753 1331 477 870 621 1016 417 892 556 872 344 656 462 766 312 565 420 635

PERFORMANCE IN INCHES WG .25 .5 1 2 3 4


2143 2059 2810 2024 1967 3064 1519 2084 1648 2128 1936 1480 1868 1725 1207 1687 1367 1045 1505 1082 864 1168 1045 744 994 789 643 878 673 557 722 2630 2672 3251 3649 4027 2506 2560 3398 3721 4027 2437 2182 2535 2904 3233 2294 1962 2218 1957 1617 1940 2189 2416 1600 1370 1716 1907 2090 1339 1127 1353 1526 1681 1212 950 1145 1283 1407 940 844 1017 1143 1259 796 721 838

* May vary depending on motor size. All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet fan sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

944

1046

For complete product information refer to catalog Model TCB, or contact your local representative.
56
CEiliNg, CAbiNET AND iNliNE FANS

Greenheck Fan Corporation certifies that the model TCB tubular centrifugal inline fans shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL - 705 UL-762

Tubular Centrifugal Fans - TCF


Tubular centrifugal fans are for use in commercial and industrial applications that demand quiet, efficient and reliable air movement. Models can be used in exhaust, supply, and return-air, clean or contaminated air ventilation installations with continuous airstream temperatures up to 200F. Units may be ceiling hung, floor mounted or roof mounted.

PERFORMANCE
Performance capabilities range from 1,600 cfm to 90,000 cfm for TCF Horizontal with up to 81/2 in. wg of static pressure, and 1,600 cfm to 30,200 cfm for TCF Vertical with up to 5 in. wg of static pressure.

SERVICE CHART
Tubular Centrifugal Fans All Models

10 DAY

OPTIONS AND ACCESSORIES


Hinged access door Totally enclosed belt guard Companion flanges Drain connection Inlet and outlet guards Shaft seal - felt or neoprene Type C Construction (Arr. 9) Type B Construction (Arr. 9) Isolators - neoprene and spring (Motor positions A & E only) Motor cover UL/cUL-705 (Electrical) UL listed Power Ventilators for Smoke Control Systems Greenheck coatings (See coatings page 119)

STANDARD CONSTRUCTION FEATURES


AMCA Certified for air performance Permatector coating Final assembly vibration analysis Minimum bearing life of L(10) 80,000 hours (Average life - L(50) of 400,000 hours) Continuously welded housing Airfoil blade steel backward-inclined wheel Inlet and outlet flanges with mounting holes Drive chamber and belt tube Straightening vanes Extended lube lines

Motor Positions for Horizontal Fans (Discharge Views) A A H G B

ARRANGEMENT

MOUNTING Horizontal Base Mount Horizontal Ceiling Hung Vertical Base Mount Vertical Ceiling Hung

CLASS I, II I, II I I

MOTOR POSITION A, B, C, G, H A, D, E, F Not Applicable Not Applicable

3, 9

C
9

F Base Mount Units E

Ceiling Hung Units

Airflow

Airflow

Airflow

Airflow

UBFM

UBCH

DBFM

DBCH

Optional Discharge and Mounting Bracket Locations for Vertical Fans


Greenheck Fan Corporation certifies that the TCF fans shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL - 705 UL Listed Power Ventilators for Smoke Control Systems

For complete product information refer to catalog Model TCF, or contact your local representative.

CEiliNg, CAbiNET AND iNliNE FANS

57

Mixed Flow - QEI


The QEI mixed flow fan is a low sound, highly efficient alternative for inline ventilation. The unique axial/centrifugal hybrid wheel design captures the highly efficient straight-through airflow of vane axials and the lower sound levels of tubular centrifugal fans to provide an energy efficient product that wont be a noise distraction in your ventilation system.

Axial

Centrifugal

Mixed Flow

Flexible Universal Mounting System allows for field rotation of motor location.

All motors are mounted on adjustable pivot bases for easy adjustments.

Sealed belt guard protects personnel and minimizes air leakage around motor shaft.

Extended collar on inlet and outlet allow for quick and easy slipfit duct connections to ductwork or plenum wall. Permatector coating is an industrial grade, electrostatic powder paint. Provides a durable, long lasting finish for interior or exterior applications.
Flexible Sleeve Fan Duct

Integral, spun inlet cone provides even airflow into the wheel in ducted or nonducted applications and helps to reduce system effects associated with uneven duct velocity profiles. Mixed flow wheels are designed with single-thickness, cambered blades to maximize free area and efficiency. Tight wheel to cone tolerances further improve the mechanical efficiency. 100
Sound Power, dB

Cast flange mounted bearings are air-handling quality and use concentric bore locking systems for smooth operation. Bearings are selected for a minimum L(10) life in excess of 80,000 hours at the maximum fan class RPM. {Average life L(50) of 400,000 hours} Aerodynamically designed straightening vanes improve performance by converting kinetic energy of swirling air into useful static pressure.

LOWER SOUND POWER, BETTER SOUND QUALITy

90

100
QEI Typical Vane Axial Typical Centrifugal

The sound quality of the QEI is as beneficial to low sound 80 design as is the reduced overall sound power. The sound chart compares units of similar outer tube diameters at an operating point of 20,000 cfm with 1.5 inches wg of static 70 pressure (Ps). Tubular centrifugals (green) have dominant tones in the 63 hz through 250 hz octave bands, while vane axials (red) have more mid to high frequency sound. The 60 QEI does not have a dominant tone. A bystander would 62 hear a more bland sound that is quieter than a tubular centrifugal or vane axial.

Sound Power, dB

90

80

QEI Typical Vane A Typical Centri

70

125
60

250

500

1000

2000

4000

8000

Frequency, Hz
62
QEI Typical Vane Axial Typical Centrifugal
QEI

125

250

500

1000

2000

4000

8000

Frequency, Hz

58

CEiliNg, CAbiNET AND iNliNE FANS

Typical Vane Axial Typical Centrifugal

Mixed Flow - QEI


Mixed flow fans are for use in commercial and industrial applications that demand quiet, efficient and reliable air movement. Models can be used in exhaust, supply, and return-air, clean or contaminated air ventilation installations with continuous airstream temperatures up to 200F. Units may be ceiling hung, floor mounted or roof mounted.

PERFORMANCE
Performance capabilities range from 2,000 cfm to 95,000 cfm and up to 81/2 in. wg of static pressure.

SERVICE CHART
QEI - Class I & II All Sizes

10 DAY

STANDARD CONSTRUCTION FEATURES


AMCA Certified for Sound and Air Performance Permatector coating Final assembly vibration analysis Minimum bearing life of L(10) 80,000 hours {Average life - L(50) of 400,000 hours} Continuously welded housing Universal mounting system Slip-fit collar for duct connections Mixed flow wheel w/steel cambered blades Straightening vanes Extended lube lines Bolted inspection door

TyPICAL APPLICATIONS
Office Buildings Concert Halls Libraries Parking Garages Educational Facilities Dormitories

MOUNTING FOR SIZES 15 - 27 (Viewed from discharge)

One configuration for horizontal and vertical applications. Allows for field rotation of motor position.

Vertical Ceiling Hung

OPTIONS AND ACCESSORIES


Belt tube Companion flange Inlet and outlet guards Isolators - neoprene and spring Motor cover Mounting rails (Horizontal and all vertical applications) Copper lube lines UL/cUL-705 (Electrical) UL Listed Power Ventilators for Smoke Control Systems UL Listed Power Ventilators for Restaurant Exhaust Systems Greenheck coatings (See coatings page 119) Roof upblast options available Totally enclosed belt guard or motor cover Sure-Aire airflow monitoring station

Optional Mounting Rails

Horizontal Base Mount

Fig. 1

Horizontal Base Mount Motor at 3 (C) or 9 Oclock (G) Position

Fig. 2

Vertical Base Mount

Fig. 5

Optional Mounting Rails

Horizontal Ceiling Hung

Horizontal Ceiling Hung Motor at 3 (C) or 9 Oclock (G) Position

Fig. 3

Fig. 4

MOUNTING FOR SIZES 30 - 54 (Viewed from discharge)


Available in horizontal and vertical configurations. Horizontal applications allow for field rotation of motor position.
H G A
A

B
G C F E D

The Sure-Aire airflow monitoring station measures fan flow within an accuracy of 2-3%. Unlike traditional flow probes that block air passing through the inlet of the fan venturi, the SureAire does not interfere with airflow and will not impact the fans air or sound performance.

MODEL QEID
Greenheck Fan Corporation certifies that the Models QEI and QEID mixed flow inline fans shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. For QEID performance pages showing AMCA licensed data for sound and air performance, please refer to the QEID Sound and Air Performance Supplement.

(Consult factory for Direct Drive availability)

UL/cUL - 705 UL Listed Power Ventilators for Smoke Control Systems UL 762 UL Listed Power Ventilators for Restaurant Exhaust Systems

For complete product information refer to catalog Models QEI & QEID or contact your local representative.
CEiliNg, CAbiNET AND iNliNE FANS

59

Tube Axial TDI/TBI-CA/TBI-FS

Model TDI direct drive tube axial fans are best suited for applications moving relatively clean, dry and cool air in commercial and industrial applications.

Model TBI-CA belt drive is a good selection where the motor must be mounted out of the airstream. Used with temperatures up to 200F or contaminated air. Three levels of construction available.

APPLICATIONS

Clean Air Fume Exhaust SparkResistant Construction

APPLICATIONS

Model TBI-FS belt drive fans have motors out of the airstream. They are a good choice for clean or contaminated airstreams with temperatures up to 400F. Three levels of construction available.

Clean Air Fume Exhaust SparkResistant Construction

APPLICATIONS

PERFORMANCE

Capacities range from 2,100 cfm to 48,400 cfm and up to 0.875 in. wg of static pressure.

PERFORMANCE

Capacities range from 800 cfm to 96,000 cfm and up to 3.25 in. wg of staticpressure.

High Temperature Process UL/cUL Emergency Smoke Industrial Space Contaminated Air

PERFORMANCE

TDI STANDARD PERFORMANCE & DIMENSIONAL DATA


MODEL
TDI-3-18 TDI-3-20 TDI-3-24 TDI-3-30 TDI-3-36 TDI-3-42 TDI-3-48

Capacities range from 4,800 cfm to 76,000 cfm and up to 4 in. wg of staticpressure.

A (I.D.)
183/8 203/8 243/8 303/8 363/8 421/2 481/2

B (O.D.)
211/16 231/16 271/16 339/16 399/16 453/4 523/4

C (B.C)
193/4 213/4 253/4 32 38 443/16 503/4

D
18 19 19 21 21 27 27

MIN/MAX RPM
1140 1725 1140 1725 860 1140 1725 860 1140 1725 860 1140 1725 680 860 1140 680 860 1140

4190 5873 5336 7018 6215 9028 12599 12478 15600 20634 21839 26098 33394 24214 27070 40594 32194 38105 48408

3773 5657 4946 6683 5391 8399 12226 11175 14763 19895 20153 24952 32488 21392 25358 39128 28973 35525 46588

PERFORMANCE IN INCHES WG .125 .25 .5 .75 .875


3189 5417 4454 6355 4313 7667 11837 9659 13793 19175 18236 23760 31582 18362 23243 37338 24774 32712 44919 4749 5594 10922 11494 17718 21096 29765 17850 34109 25851 41349 3919 4443 9919 15819 17968 27577 29879 35525 9380 14739 26395 25360 32815

Charts shown are for level 3 performance. For complete performance ratings for levels 3, 4 & 5, refer to the CAPS program or to catalogs Model TDI, TBI-CA level 3 and Model TBICA level 4 & 5, or contact your local representative.

All dimensions in inches. Performance certified is for installation type D: Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).

TBI-CA STANDARD PERFORMANCE & DIMENSIONAL DATA


MODEL
TBI-CA-3L18 TBI-CA-3H18 TBI-CA-3H18 TBI-CA-3H20 TBI-CA-3H24 TBI-CA-3H30 TBI-CA-3H36 TBI-CA-3H42 TBI-CA-3H48 TBI-CA-3H54 TBI-CA-3H60

A (I.D.)
183/8 183/8 183/8 203/8 243/8 303/8 363/8 421/2 481/2 55 61

B (O.D.) C (B.C)
215/8 215/8 215/8 235/8 275/8 335/8 395/8 453/4 523/4 591/4 651/4 193/4 193/4 193/4 213/4 253/4 32 38 441/4 503/4 571/4 631/4

D
22 22 22 22 23 24 29 30 33 371/2 40

E
213/4 213/4 213/4 231/4 26 291/4 333/4 371/4 401/2 471/4 503/4

MIN/MAX RPM
1890 3000 1610 2710 1189 2290 1056 2225 977 1990 848 1815 763 1710 594 1326 490 1024 476 910 507 970

1914 3225 2171 3874 2698 5583 3126 7186 4931 10858 7473 17648 10388 25929 13266 32585 16808 38804 27099 56134 37656 76735

.125

PERFORMANCE IN INCHES WG .25 .5 .75 1


1659 3103 1937 3758 2331 5450 2618 7032 4223 10619 6405 17222 8620 25301 10728 31815 14083 37720 23391 54567 33757 74906 2825 3502 5152 6673 10085 2427 3209 4781 6234 9422 1868 2832 4358 5761 8718 14327 21122 26506 30421 42975 62911

1.25
1253

5483 7926 13167 19364 23892 25718

16278 15321 23973 22609 30334 28652 35371 33046 51229 47707 71249 67412

Greenheck Fan Corporation certifies that the models TDI & TBICA tube axial fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

57746

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

60

CEiliNg, CAbiNET AND iNliNE FANS

Tube Axial TDI/TBI-CA/TBI-FS


SERVICE CHART
E C B A O.D. I.D. Airow

10 DAY

TDI - All sizes TBI-CA - All sizes TBI-FS - All sizes

OPTIONS AND ACCESSORIES


TDI TBI-CA / FS n n n n n n n n n n n n n n n n n n n n n n (FS) n (FS)
MIN/MAX RPM
971 1988 1122 2707 794 1834 870 2306 660 1476 782 1824 611 1271 689 1607 479 1147 795 1509 423 999 675 1337

OPTIONS AND ACCESSORIES UL/cUL-705 (Electrical) Shaft Seal Belt Guard Bolted or Hinged Access Door Motor Cover Inlet and Outlet Guards Inlet Bell Companion Flanges Isolators - Base, Hanging, and Spring NEMA-1 & 3R Disconnect Switches Greenheck Coatings (See page 119) Inspection Section Mounting Rails Continuous Duty High Temperature UL Power Ventilators For Smoke Control
PERFORMANCE IN INCHES WG 1.5 2 3
6827 11825 11006 18271 16514 25857 17430 30713 22055 44702 35171 57710 56126 48925 36972 42568 37957 30148 29526 24753 15561 24376 20432 13643 17201 13614 9546 11228 9161 5907

n STANDARD CONSTRUCTION FEATURES Continuously Welded Housing Cast Aluminum Hub and Blades n Fabricated Steel Hub and Blades AMCA Certified for Air Performance AMCA Certified for Sound Permatector Coating Universal Mounting System Belt Tube and Bearing Cover Minimum Bearing Life of L(10) 80,000 Hrs Extended Lubrication Lines

STANDARD CONSTRUCTION FEATURES


TDI TBI-CA TBI-FS n n n n n

n n

n n

n n n n n

n n n n n

TBI-FS INLINE PERFORMANCE & DIMENSIONAL DATA


MODEL
TBI-FS-3H 24 TBI-FS-4H 24 TBI-FS-3H 30 TBI-FS-4H 30 TBI-FS-3H 36 TBI-FS-4H 36 TBI-FS-3H 42 TBI-FS-4H 42 TBI-FS-3H 48 TBI-FS-4H 48 TBI-FS-3H 54 TBI-FS-4H 54

A
243/8 243/8 303/8 303/8 363/8 363/8 421/2 421/2 481/2 481/2 55 55

B
275/8 275/8 335/8 335/8 395/8 395/8 453/4 453/4 523/4 523/4 591/4 591/4

C (B.C)
253/4 253/4 32 32 38 38 441/4 441/4 503/4 503/4 571/4 571/4

D
23 28 24 33 29 34 30 39 33 44 371/2 48

E
26 28 291/4 323/4 333/4 351/4 371/4 40 401/2 451/2 471/4 491/4

5425 9990 8256 14545 11834 23800 16553 26614 18483 34369 25121 48511

.125

.5
9416 5439 12829 13838 7653 20075 22460 11824 27723 25157 15343 33454 31753 29849 47501 46357 39677 61340

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power ratings (BHP/kW) do not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA, sound power levels for installation type B: free inlet, ducted outlet. Ratings do not include the effects of end correction.

Greenheck Fan Corporation certifies that the model TBI-FS shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

For complete product information on Greenhecks Tube Axial fans, please refer to the CAPS program or to catalogs TDI, TBI-CA level 3, TBI-CA level 4 & 5, and TBI-FS, or contact your local representative.
CEiliNg, CAbiNET AND iNliNE FANS

61

Vane Axial Belt Drive - VAB


Model VAB fans feature the advantages of final system balancing, motor access, manually adjustable blade pitch, economical future upgrading, and the capability to operate in airstream temperatures up to 200F. Fan sizes 18-48 are available on QB.

PERFORMANCE

Capacities available on QB range from 2,000 cfm to 70,000 cfm and up to 7 in. wg of static pressure. Arrangement 9 belt drive.

SERVICE CHART
VAB - Sizes 18-48 - Class I MOUNTING OPTIONS

10 DAY

HORIZONTAL MOUNTING LEGS Heavy-gauge steel support legs welded to the fan are punched to accept neoprene or spring vibration isolators.

STANDARD CONSTRUCTION FEATURES


AMCA Certified for air performance Permatector coating Final assembly vibration analysis Continuously welded housing Cast aluminum hub and blades Straightening vanes Extended lubrication lines

HORIZONTAL SUSPENSION BRACKETS Brackets welded to the fan housing for horizontal ceiling hung applications are punched to accept hanging neoprene or spring isolators.

OPTIONS AND ACCESSORIES


Belt guard Motor cover Inlet bell Companion flanges Inspection section Inlet/outlet cone Safety screen for housings, inlet bell, and inlet/outlet cones Horizontal or vertical mounting options UL/cUL-705 (Electrical) Greenheck coatings (See coatings page 119)

VERTICAL BASE OR SUSPENSION BRACKETS Brackets welded to the fan housing for vertical base mount or vertical ceiling hung applications are punched to accept vibration isolators. Customer must specify one of the mounting arrangements shown below.

UBFM

UBCH

DBFM

DBCH

VAB DIMENSIONAL DATA


MODEL VAB-18 A 183/8 203/8 243/8 303/8 363/8 421/2 481/2 B 213/4 233/4 273/4 333/4 393/4 47 53 C 131/2 15 171/2 211/4 25 29 34 D 32 32 36 40 40 44 48

Optional Inlet B A Bell

Vane Axial Fan


AIRFLOW

Optional Inlet/Outlet Cone C

VAB-20 VAB-24 VAB-30 VAB-36 VAB-42 VAB-48

All dimensions in inches.

For complete product information, refer to the CAPS program or to the catalogs pertaining to the Vane Axial product line, or contact your local representative.
62
CEiliNg, CAbiNET AND iNliNE FANS

AMCA Licensed air performance can be found in Greenheck Fan Corporations supplement VxPM12-96 R - December 1996.

Direct Drive - S
Sidewall propeller direct drive fans have varied model configuration arrangements available to handle exhaust and supply requirements. Propellers are available in fabricated aluminum, fabricated steel, or cast aluminum blades depending on the level of construction. Three levels of construction are available. Direct drive fans are often preferred for jobs where maintenance access is difficult.

LEVEL 1 - SIZE 8-12 - D, G, E Motor Speeds


A Sq. B* C* D F* D

Exhaust
Airow

Supply
Airow

LEVEL 1 - SIZE 12-24 - A, B, C Motor Speeds, LEVELS 2 & 3


A sq. G sq. B* C* D F* D

PERFORMANCE
Performance capabilities range from 115 cfm to 51,206 cfm and up to 1 in. wg of static pressure.
Exhaust
Airow

Supply
Airow

DIRECT DRIVE S STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA - STEEL PROPELLER
B* EXHAUST F* SUPPLY C* EXHAUST LEVEL LEVEL LEVEL MODEL A PANEL 1 S-8 S-10 S-12 S-14 S-16 S-18 S-20 S-24 S-30 S-36 S-42 S-48 S-54 13 15 18 20 22 24 26 32 38 44 50 56 62 7 834 1034 1114 1134 14 1714 20 2 1312 1312 1714 20 2012 2012 26 2658 28 1 8 8 1318 1414 14 1414 18 21 2 14 1414 18 21 2134 28 28 2812 3018 1 5 5 814 812 878 1078 11 1258 2 1014 1014 1312 1312 1638 1638 1814 2058 22716 1 1 1 1 1 1 1 114 114 2 2 2 2 D E EXHAUST LEVEL 1 838 1038 1238 1438 1638 1838 2012 2438 2 1638 1838 2012 2458 3058 3658 4258 4914 5538 n n n n n n n 1050 1650 1050 1650 860 1750 860 1750 860 1750 860 1750 860 1750 860 1750 860 1160 860 1160 860 860 860 860 690 860 1.5 3.9 3.2 5.2 4.0 8.7 5.9 14.8 5.0 23 8.7 22 10.8 35 9.1 41 23 33 27 40 30 41 43 53 52 54 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 6 6 6 4 4 4 4 STOCK SIZES (n)

n Performance for available in stock sizes is shown on page 64


PERFORMANCE IN INCHES WG

MIN/MAX SONES # PROP RPM @ 0 in. BLADES PITCH 40 28 40 28 32 32 40 36 36 30 34 21 28 35 32 15 18 20 7 14 2 27 7 22 20 16

0 311 329 626 606 804 1636 1189 2734 2003 3531 2661 4177 3133 7266 5000 9537 9698 13905 9985 18400 8673 28811 18124 34332 41542 45612

.1 126 266 361 536 511 1515 919 2615 1732 3344 2202 4015 2823 6980 4540 9310 9066 13434 9347 17945 7991 27924 17081 33166 39736 44465

.15

.25

.5

214 484 348 1447 649 2553 1433 3250 1874 3931 2641 6837 9197 8707 13198 9012 17718 7632 27480 16565 32583 38845 43892 272 1282 408 2422 849 3058 3683 2085 6543 8961 7892 12665 8255 17263 6888 26533 15499 31257 37177 42745 947 1829 2303 3059 5453 8315 6559

11144 5325 15787 10993 4937 24002 12067 27990 32089 39103 30171

*May vary due to motor sizes. All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

For complete product information refer to catalog Sidewall Propeller Fans, or contact your local representative.

Greenheck Fan Corporation certifies that the S models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

UL/cUL 705 E40001-S

CEiliNg, CAbiNET AND iNliNE FANS

63

Direct Drive - S
SERVICE CHART
SE1-8 through 20 SE1-24 & all other models, levels & sizes up to 48 All other models, levels & sizes 54 and up

IN 3 5 10 STOCK DAY DAY DAY


STANDARD CONSTRUCTION FEATURES


Heavy-gauge, galvanized steel fan panel with pre-punched mounting holes Resilient motor mounts isolate motor vibrations Corrosion-resistant fasteners ODP single-phase Thermal overload protection with all motors Level 1 Riveted Aluminum Blades Sizes 8-12 (D, G, E motor speeds) - Heavy-gauge welded zinc plated wire drive frame Sizes 12-24 (A, B, C motor speeds) - Die formed, galvanized steel drive frameassembly Level 2 Welded steel blades and Die formed, galvanized steel drive frameassembly Level 3 Cast Aluminum blades and Die formed, galvanized steel drive frame assembly

DIRECT DRIVE SC STANDARD CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA - CAST ALUMINUM PROPELLER
MODEL B* EXHAUST F* SUPPLY C* EXHAUST A PANEL LEVEL LEVEL LEVEL D E MIN/MAX SONES # PROP RPM @ 0 in. BLADES PITCH 0

in stock sizes not available for sc


PERFORMANCE IN INCHES WG .1 .15 .25 .5 1

SC3-20 SC3-24 SC3-30 SC3-36 SC3-42 SC3-48 SC3-54

26 32 38 44 50 56 62

17 4
1

18 21 213/4 28 28 28 2
1

13 2
1

1 114 1 4
1

2012 2458 30 8
5

20 20 2
1

1312 16 8
3

20 2
1

16 8
3

2 2 2 2

3658 4258 49 4
1

26 26 8
5

1814 20 8
5

28

30 8
1

22 16
7

5538

1160 1750 860 1750 860 1160 860 1160 690 860 690 860 690 860

22 42 16.7 53 16.5 40 25 49 25 36 32 53 28 50

6 4 6 6 3 6 4 6 6 6 4 6 3 3

17 29 20 20 15 25 7 17 10 20 10 30 6 23

3243 6005 4777 9721 7276 14779 11645 21781 14274 24242 18398 43290 24805 51206

2990 5797 4292 9501 5972 14160 10275 20957 13009 23108 15714 41324 22316 48980

2851 5692 3999 9391 5236 13849 9546 20546 12182 22474 14090 40167 20953 47828

2529 5434 3312 9159 2816 13220 7632 19710 10210 21181 10042 37745 17603 45404

4739 8488 6886 11276 17398 16580 30731 39307

*May vary due to motor sizes. All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

DIRECT DRIVE SE1 PERFORMANCE DATA - IN STOCK


MODEL MOTOR SONES SPEED @ 0 in.
E SE1-8-DGEX-QD G D E SE1-10-DGEX-QD G D E SE1-12-DGEX-QD SE1-14-BX-QD SE1-16-436-BX-QD SE1-18-BX-QD SE1-20-BX-QD G D B B B B 1.5 3.5 4.9 3.2 4.9 5.9 4.3 6.0 7.5 7.3 9.5 7.2 14.3

Stock Model SE1 fans are direct drive exhaust and include aluminum propeller, heavy-gauge wire motor support, fan guard, UL/cUL 705 and CSA labels.

FAN RPM
1050 1350 1550 1050 1350 1550 1050 1350 1550 1160 1160 1160 1160

# BLADES
4 4 4 4 4 4 4 4 4 4 4 4 4

PROP PITCH
40 40 40 40 40 40 32 32 32 40 36 29 28

DAMPER
10 x 10 10 x 10 10 x 10 12 x 12 12 x 12 12 x 12 14 x 14 14 x 14 14 x 14 16 x 16 18 x 18 20 x 20 22 x 22

PERFORMANCE IN INCHES WG 0
311 399 459 626 804 924 981 1262 1449 1604 2702 3238 4227

.1
126 256 351 361 655 800 744 1097 1309 1406 2512 2987 4030

.125
100 198 307 615 763 678 1037 1271 1350 2461 2908 3974

.25

.375

167

383 798 1042 908 2067 2434 3621 540 860 720 1359 1510

All dimensions in inches. Performance certified is for installation type A: Free inlet, Free outlet. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

64

CEiliNg, CAbiNET AND iNliNE FANS

Belt Drive - SB
Sidewall propeller belt drive fans have varied model configuration arrangements available to handle exhaust and supply requirements. Propellers are available in fabricated steel, or cast aluminum blades depending on the level of construction. Three levels of construction are available. Also two blade designs are available: The L design is for low static pressures and low sound levels. The H design is for higher static pressures. Belt drive fans offer the ability to adjust fan speed for system balancing if necessary.

SERVICE CHART
SBE-20 through 36 SBE, SBS & SBC up to size 48 All other models, levels and sizes 54 and up

IN 3 STOCK DAY

5 DAY

10 DAY

PERFORMANCE
Performance capabilities range from 304 cfm to 87,025 cfm and up to 1 in. wg of static pressure.

LEVEL 1 & 2
A sq.

LEVEL 3
A sq.

STANDARD CONSTRUCTION FEATURES


Die formed, galvanized steel drive frame assembly Adjustable motor pulley Ball bearing motors Fan shaft mounted in ball bearing pillow blocks Static-resistant belts Corrosion-resistant fasteners Level 1 Galvanized and riveted steel blades Level 2 Reinforced Galvanized steel blades Level 3 (SB) Welded Steel Blades Level 3 (SBC) Cast Aluminum Blades

B C

F D D
Exhaust
Airow

Supply
Airow

OPTIONS
Aluminum propellers (SB1 and SB-2) UL/cUL 705 Electrical Relubricatable bearings Extended Lube Lines Dual Drives Horizontal Mounting Greenheck Coatings (See coatings page 119) (5 & 10 day quick build)
E E

Exhaust
Airow

Supply
Airow

D B

D F

OPTIONS AND ACCESSORIES - S/SB

3 5 10 In Stock Day Day Day

Wall Housings (sizes 8 through 36) Wall Housings (sizes 42 and 48) Wall Housings (sizes 54 and up) Wall Collar Kit (sizes 8 through 36) * Wall Collar Assembled (sizes 42 and 48) Wall Collar Assembled (sizes 54 and up) Motor Side Guard (sizes 14 through 36) Motor Side Guard (sizes 42 and 48) Motor Side Guard (sizes 54 and up) Damper Guard * 45 Weatherhoods exhaust only (sizes 8 through 36) 45 Weatherhoods exhaust only (sizes 42 and 48) 45 Weatherhoods exhaust only (sizes 54 and up) 90 Turndown Weatherhoods (sizes 8 through 36) * 90 Turndown Weatherhoods (sizes 42 and 48) 90 Turndown Weatherhoods (sizes 54 and up) Extended and 1-Point wiring + End Switches ++ Gravity and Motorized Dampers * WI only + Is available where a fan and motorized damper are factory mounted together in a wall housing ++Available only if selected with a motorized damper

Greenheck Fan Corporation certifies that the SB models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program.

For complete product information refer to catalog Sidewall Propeller Fans, or contact your local representative.
UL/cUL 705 E40001-SB

CEiliNg, CAbiNET AND iNliNE FANS

65

Belt Drive - SB
BELT DRIVE SB CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA - STEEL PROPELLER n Performance for available in stock sizes is shown on page 67
MODEL A PANEL B EXHAUST F SUPPLY C EXHAUST LEVEL LEVEL LEVEL 1&2 SB-20 26 1912 3 1&2 20 3 1&2 1614 3 1 D E EXHAUST LEVEL 1&2 201/2 3 STOCK SIZES (n) LEVEL
Level 1 only

MAX RPM 1085 1221 1241 1391 809 1010 986 1148 1127 1485 696 882 950 1221 1100 1432 551 694 693 870 819 1321 424 533 723 907 762 951 355 429 608 734 686 862 343 377 508 562 619 779 399 521 503 659 492 559

PERFORMANCE IN INCHES WG SONES* 17.9 20 22 25 17.4 19.9 33 25 27 28 19.2 22 32 36 41 49 17.7 20 27 34 28 59 18.8 21 39 56 33 43 15.4 19.3 36 39 44 54 17.3 19.0 44 40 56 75 31 47 72 70 57 75 0 5550 4587 6348 5226 7598 5281 9260 6003 8873 7746 11517 10078 15720 13951 17423 15173 15896 15253 19993 19121 22544 23810 19759 18408 33693 31324 32563 28764 22875 21827 39177 37344 45088 39021 30129 28832 44623 42980 54526 50022 53242 45754 67120 57873 86854 84449 .125 4919 4277 5764 4954 6935 4819 8738 5606 8337 7425 10456 9342 14985 13414 16709 14820 14146 13798 18744 18096 21378 23304 16705 16388 32120 30294 31113 27822 19220 18907 37271 35695 43262 37910 26014 25408 41857 41032 52198 48396 47929 43208 62923 55735 83861 81436 .25 4269 3873 5325 4639 5948 4193 8139 5122 7686 7073 8874 8560 14152 12889 15991 14468 11731 12111 17106 16736 20081 22799 13752 30386 29095 29634 26939 13506 35157 33991 41495 36800 16537 19924 39088 38498 49736 47032 41676 41233 58582 54054 80838 79030 .5 2514 3741 2108 3343 5569 6271 .75 1064 1886 904 1853 5208 910 3470 1138 1

SB-24

32

1912

19

20

2012 1618

1558

114

2458

2458

SB-30

38

2112

2112

21

20

1714

1714

114

3058

3058

SB-36

44

2112

28

22

27

1612

23

3658

3658

SB-42

50

25

28

2512

2914

20

23

4234

4234

SB-48

56

25

3112

2512

3012

19

2712

4834

4834

SB-54

62

26

3534

24

3614 2012

3014

5514

5514

SB-60

68

28^

35

24^

3512 21716 28716

6114

6114

SB-72

82

35

3512

2814

218

7314

1L 1H 2L 2H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 1L 1H 2L 2H 3L 3H 2L 2H 3L 3H 3L 3H

11760 11734 14241 13586

9980 11254 12446

11176

13871 16505 21711

20233

18473

26322 26299 25934 25063

22915 22589 19606

29209 29911 36866 34248

22215 30989 27270

28363 32079 42826 44548 34835 50625 73537 74244

33870 41129

35732

45470 67313

All dimensions in inches. *Sones shown apply to the highest cataloged CFM in bold type at each fan RPM. ^ = LEVEL 2 ONLy Please note: Optimum selections shown in bold.

BELT DRIVE SBC CONDENSED PERFORMANCE RANGES & DIMENSIONAL DATA - CAST ALUMINUM PROPELLER
MODEL A PANEL B EXHAUST F SUPPLY C EXHAUST SBC-24 SBC-30 SBC-36 SBC-42 SBC-48 SBC-54 SBC-60 SBC-72
32 38 44 50 56 62 68 82 19 2112 28 28 3112 35 4
3

in stock sizes not available for sBc

D
114 114 2 2 2 2 2 218

E
2458 3058 3658 42 4
3

LEVEL
3L 3H 3L 3H 3L 3H 3L 3H 3L 3H 3L 3H 3L 3H 3L 3H

MAX RPM
1194 1396 1262 1616 1183 1480 916 1259 908 1182 727 856 620 775 578 795

SONES*
24 26 40 47 51 58 42 57 50 75 61 61 56 63 72 104

0
8225 7958 17404 15634 27372 25311 31269 29397 45707 43876 50894 50182 61816 59656 87026 85183

PERFORMANCE IN INCHES WG .125 .25 .5 .75


7788 7564 16632 15111 26355 24537 29539 28561 43334 42275 49204 48654 58573 56913 81173 82395 7253 7126 15835 14596 25194 23751 27517 27590 40528 40859 46850 47126 55354 54624 73547 79290 5677 6208 13842 13579 22246 22117 23038 25446 34664 37668 41235 43599 44587 49309 53266 73186 5051 11164 12487 20313 22881 34068 39367 42537 65974

1
1966 11270 18538 19615 29382 33873 31181 55871

2012 20 27 29 4
1

1558 1714 23 23 271/2 30 4


1

3012 36 4
1

4834 55 4
1

35 35

3512 3512

28716 2814

6114 7314

All dimensions in inches. Please note: Optimum selections shown in bold. *Sones shown apply to the highest cataloged CFM in bold type at each fan RPM. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only.

66

CEiliNg, CAbiNET AND iNliNE FANS

Belt Drive - SB
SB PERFORMANCE DATA - IN STOCK
MODEL NUMBER MOTOR HP
1

in stock sizes are belt drive exhaust and include steel propellers UL/cUL 705.

FAN RPM 705 861 889 947 1021 1085 773 953 998 1039 1107 1221 513 593 614 653 704 748 390 475 491 523 564 598 645 685 329 384 412 438 471 500 518 551

MAx BHP 0.17 0.30 0.33 0.40 0.50 0.60 0.17 0.30 0.37 0.40 0.50 0.60 0.19 0.30 0.33 0.40 0.50 0.60 0.16 0.30 0.33 0.40 0.50 0.60 0.75 0.90 0.25 0.41 0.50 0.61 0.76 0.90 1.01 1.21

SONES* 11.6 14.3 14.9 16.1 17.0 17.9 11.1 16.2 16.7 17.2 18.0 20 10.3 11.8 12.4 12.8 13.8 14.8 9.5 11.6 12.1 13.0 14.3 15.5 17.2 18.7 12.3 11.8 12.7 13.6 14.5 15.3 16.1 17.7

PERFORMANCE IN INCHES WG 0 3606 4404 4547 4844 5222 5550 2904 3581 3750 3904 4159 4587 4818 5569 5766 6133 6612 7025 6453 7860 8125 8654 9333 9895 10673 6394 6742 7427 8261 8898 9766 5880 6249 6970 7862 8583 9508 6503 7436 8185 9190 7366 8446 7562 8622 .1 2836 3795 3950 4271 4675 5021 2453 3247 3436 3608 3885 4339 3784 4803 5040 5466 6000 6455 4551 4807 5256 5831 6300 4050 4396 5037 5628 6128 4992 5723 4939 .125 2451 3672 3830 4156 4566 4919 2293 3148 3342 3517 3805 4277 3455 3655 4044 4461 4817 2112 3034 3244 3427 3720 4203 3067 3648 4181 4621 1596 2769 3006 3212 3534 4049 3747 4269 924 2469 2727 2954 3315 3873 3712 676 2002 2398 2676 3065 3675 304 1160 1588 2037 2599 3333 657 873 1064 1368 2514 393 603 935 1456 502 1064 .15 .2 .25 .3 .375 .5 .625 .75 1

SBE-1L20-LMDX-QD 705-1085 RPM

SBE-1H20-LMDX-QD 773-1221 RPM

SBE-1L24-LMDX-QD 513-748 RPM

SBE-1L30-LMDX-QD 390-685 RPM


1

11335 10496 9491 11078 11886 6448 8915 9913

10253 10009 9332

8018 9250 10290

6662 8354 9572

SBE-1L36-LMDX-QD 329-551 RPM


3

12636 10809 13588 11925 14425 12890 14944 13482 15896 14558

11442 10947 9408 12435 11981 10808 8915

13044 12605 11569 10084 14146 13733 12908 11731 10007

Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: Free inlet hemispherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. *Sones shown apply to the highest cataloged CFM in bold type for each fan RPM.

CEiliNg, CAbiNET AND iNliNE FANS

67

Sidewall Fan Accessories - S/SB

Weatherhood* (45Exhaust only shown) Damper Guard* Damper Wall Housing and OSHA Guard - (Std.)

W.O.

C B

WALL HOUSING DIMENSIONAL DATA


SIZE 8 10 12 14 16 18 20 24 30 36 42 48 54 60 72 WALL A 1314 1514 1814 2014 2214 2414 2614 3214 3814 4414 5038 5638 6238 6838 8318 HOUSING DAMPER GUARD B* W.O. C D 19 1414 512 1014 19 1614 612 1214 23 1914 538 1414 26 2114 638 1614 1814 27 2314 634 1 28 25 4 6 2014 32 2714 612 2214 37 33 34 638 2614 38 39 34 6 12 3214 39 45 34 634 3814 3 44 51 4 10 4414 44 57 34 9 5014 52 63 34 7 12 5614 54 69 34 714 6214 60 84 34 712 7414 45 WEATHERHOOD 90WEATHERHOOD DAMPER SIZE E F WIDTH H J 1314 1114 1012 1638 12 10 x 10 14 78 1338 1212 1812 14 12 x 12 1638 1558 1412 2038 1638 14 x 14 1712 1758 1612 2212 1838 16 x 16 18 x 18 1812 25 2038 1958 1938 22 2158 2012 2712 2238 20 x 20 2434 2358 2212 2934 2438 22 x 22 2678 3038 2918 36 3134 26 x 26 2918 3612 3518 4018 3778 32 x 32 33 4212 4118 4512 4378 38 x 38 3534 4812 4718 4914 4978 44 x 44 4038 5458 5314 5512 56 50 x 50 4434 6078 5912 6114 6214 56 x 56 4838 67 6558 6612 6838 62 x 62 5314 7912 7818 7218 8078 74 x 74

WALL HOUSING & ACCESSORIES


Wall housings are the safest and most efficient platform for mounting of sidewall propeller fans and their optional accessories. Wall housings allow for a wide range of mounting arrangements to meet specific applications, and can be mounted flush inside, flush outside, or centered in wall. Standard construction is of galvanized steel.
*Select only one. Shown together for illustration only.

* B dimension will increase by 6 in. when a heavy duty motorized backdraft damper is specified. For complete dimensional information refer to submittal. All dimensions given in inches.

W.O.

F J

Wall Collar Motor - Side Guard

Damper

Weatherhood* (90Turndown shown) Damper Guard*

C G B

WALL COLLAR DIMENSIONAL DATA


SIZE 8 10 12 14 16 18 20 24 30 36 42 48 54 60 72 WALL COLLAR (WI - STOCK ONLY) A B* W.O. 1414 1278 1618 1478 1618 1614 7 1 17 8 16 8 1914 1978 1838 2114 2178 1838 2314 2378 1838 2514 2714 2578 1838 3178 1838 33 34 3778 1838 39 34 4378 1834 45 34 4978 1834 5134 5578 1878 57 34 6178 2018 63 34 6778 21 69 34 8178 22 8334 DAMPER GUARD C D 512 1014 612 1214 3 5 8 1414 638 1614 634 1814 6 2014 612 2214 638 2614 6 12 3214 6 34 3814 9 4414 9 5014 7 12 5614 714 6214 712 7414

45 90 MOTOR-SIDE DAMPER WEATHERHOOD WEATHERHOOD GUARD SIZE SQ. E F WIDTH H J G** 1314 1114 1012 1638 12 858 10 14 78 1338 1212 1812 14 9 12 1638 1558 1412 2038 1638 11 14 1712 1758 1612 2212 1838 11 16 1938 1958 1812 25 2038 11 18 22 2158 2012 2712 2238 11 20 2434 2358 2212 2934 2438 16 22 2678 3038 2918 36 3134 18 26 2918 3612 3518 4018 3778 21 32 33 4212 4118 4512 4378 22 38 3534 4812 4718 4914 4978 24 44 4038 5458 5314 5512 56 27 50 4434 6078 5912 6114 6212 32 56 4838 67 6558 6612 6838 32 62 5314 7912 7818 7218 8078 32 74

WALL COLLAR & ACCESSORIES


Wall collars offer an alternate method for mounting sidewall propeller fans and the optional accessories shown here. Standard construction is of galvanized steel.
*Select only one. Shown together for illustration only.

** Dimensions are for exhaust fan guard. See CAPS for supply fan and optional OSHA motor side guard dimensions. For complete dimensional information refer to submittal. All dimensions given in inches.

68

CEiliNg, CAbiNET AND iNliNE FANS

Cement Block Fan - CBF


Model CBF direct drive transfer fans are designed for economy and reliability in small size, high volume applications. Efficient propeller, venturi, and motor design results in low sound levels with minimal restriction to airflow. Works great for ventilating equipment rooms, plumbing and electrical chases.

SERVICE CHART
CBF-205

IN STOCK

Mountable in any wall construction Fits in place of a standard 16 by 8 inch concrete block Performance to 500 cfm and up to 0.4 in. wg UL/cUL Recognized motor Mounting flanges for easy installation
All dimensions in inches.

PERFORMANCE DATA
MODEL AMPS CFM SONES PERFORMANCE IN INCHES WG 0 500 8.3 0.1 465 8.3 0.125 453 8.1 0.25 390 7.8 0.375 320 7.5 0.4 300 9.4 10.50 Airow

15.625

CBF-205-QD

1.0

Performance shown is for installation type A: Free inlet, Free outlet. 7.625

18.50

12.00

Dock Fan - DF
Greenhecks dock fan, model DF, is a high velocity fan designed to recirculate air in and around loading docks, trailers, and personnel working in the area. The model DF is available with a light to provide additional visibility in dark trailers or corners. The dock fan is constructed of 14-gauge steel housing, 12-gauge steel arm and an aluminum propeller. The fan and optional light both plug into a standard 115 volt outlet.

SERVICE CHART
DF-18

10-DAY

Easy installation UL Recognized motor Guards meet OSHA guidelines

35.00 (with light installed)

30.50

25.75

5.63 9.00 15.00 21.00

PERFORMANCE DATA
MODEL DF-18 RPM Motor HP 1725 1/2 CFM Free BHP air 3,800 0.55 dBA @ Throw (ft) 5 ft. 75 45

CEiliNg, CAbiNET AND iNliNE FANS

69

Utility, Centrifugal and Radial Blowers


Centrifugal Utility Fans - SFD/SFB
Model SFD forward-curved, direct drive utility fans have been designed for applications requiring low to medium air volumes and pressures. These utility fans feature quiet and efficient forward-curved wheels. Model SFB forward-curved, belt drive utility fans operate at a relatively slow speed and provide relatively high volumes at low static pressures. The advantages are low sound levels and a wide operating range.

SERVICE CHART
SFD/SFB All Models and Sizes
C F

5 DAY

10 DAY

B H C F D E

PERFORMANCE
Model SFD performance capabilities range from 232 cfm to 2,641 cfm and up to 2.5 in. wg of static pressure. Model SFB performance capabilities range from 300 cfm to 20,000 cfm and up to 2.5 in. wg of static pressure.
B H

D SFD STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA

MODEL
SFD-6

A
141116

B
16

C
1114

D
11

E
8316

F
514

G
6

H
9116

MIN/MAX RPM
1140 1725 1140 1725 860 1725 860 1725

PERFORMANCE IN INCHES WG .125


407 667 672 1062 839 1806 1259 2641 541 467 949 487 1683 965 2525 2403 2179 1942 1621 1549 1298 989 825 330

.5

.875

1.5

2.5

SFD-7.5

14516

18116

131116

1214

818

514

958

SFD-9

1778

20516

151316

1334

1038

614

10

103/4

SFD-10

1938

24516

1858

1614

1138

63/4

12

123/4

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). Greenheck Fan Corporation certifies that the SFD and SFB models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

For complete product information refer to the CAPS program or to catalog Centrifugal Utility Fans Models SWB/SFD/SFB, or contact your local representative.

70

UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

Centrifugal Utility Fans - SFD/SFB


SFB STANDARD CONSTRUCTION FEATURES
HOUSING: Heavy-gauge steel housing with Lock-seam construction Unit support angles with prepunched mounting holes Adjustable motor plate Corrosion-resistant fasteners Entire unit is phosphatized and coated BEARINGS, SHAFT, AND WHEEL: Heavy-duty lubricatable, self-aligning ball bearing pillow blocks Polished, solid steel shafts Forward-curved fan wheel (Fans with ExP. motors include: aluminum inlet cone, aluminum rub ring, and shaft seal)

SFD STANDARD CONSTRUCTION FEATURES


HOUSING: Heavy-gauge galvanized steel housing with Lockseam construction Corrosion-resistant fasteners WHEEL: Forward-curved aluminum wheel (Fans with ExP. motors include: aluminum rub ring, and shaft seal)

OPTIONS AND ACCESSORIES


Vibration isolators Weatherhood Belt guard (Belt Drive) Gravity and motorized dampers - Model WD Shaft seal with aluminum rub ring Inlet and outlet guards Speed controls (Direct Drive) Heat slinger (Belt Drive) Drain connection (Belt Drive) Access doors - Bolted or Hinged (Belt Drive) Flanged inlets or outlets (Belt Drive) Dual drives Extended lube lines (Belt Drive) Stainless steel shaft (Belt Drive) Greenheck coatings (See coatings page 119)
C C F F

DISCHARGE POSITIONS
(Viewed from Drive Side)
CCW TH CW TH CCW BH CW BH

CCW TAD

CW TAD

CCW BAU

CW BAU

CCW DB

CW DB

CCW UB

CW UB

B
CCW BAD CW BAD

B H H

CCW TAU

CW TAU

E A

E A

SFB STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL
SFB-9 SFB-10 SFB-12 SFB-15 SFB-18 SFB-20 SFB-22 SFB-25 SFB-27 SFB-30

A
20 22 2212 2758 3678 37 3958 4112 46 4814

B
24 2658 2838 3114 42 46 5212 5734 6118 68

C
167/8 1938 2138 2338 3078 3358 3634 4038 44 4834

D
1414 1678 1678 1878 2518 2738 3034 3358 3758 4118

E
115/16 12 12 13 18 1912 20 1978 2214 2212

F
658 812 9 1234 1734 1578 1712 1912 2138 2338

G 10
11 13 1538 1914 2118 23 2578 2812 3134

H
1334 1518 1518 1658 2238 2412 2834 3112 33 3658

MIN/MAX CFM
300 1400 700 2300 900 2900 1600 4200 2400 6600 3100 7900 4000 10000 5800 13800 9000 17000 10400 20000

472 1282 450 1080 373 880 326 658 285 607 263 549 241 508 205 410 225 387 225 398

PERFORMANCE IN INCHES WG .125 .5 .875 1.5 2 2.5


1422 718 1211 613 979 511 761 454 693 398 617 359 562 308 460 302 431 297 437 1552 1335 1087 858 770 680 447 617 387 508 370 473 355 476 1797 1969 1518 1644 1255 1000 1098 1186 888 778 703 587 464 539 437 539 976 851 772 646 592 494 585 919 832 699 641 626

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

71

Centrifugal Utility Fans - SWB


Model SWB backward-inclined, belt drive utility fans have several advantages of higher operating efficiencies, a nonoverloading horsepower curve, and higher pressure capability.

SERVICE CHART
SWB 100 Series Sizes 110-124 SWB 200 Series Sizes 210, 212, 216, 220 & 224 SWB 200 Series Sizes 213, 215, 222 & 224 SWB 200 Series Sizes 227 & 236

IN 5 10 STOCK DAY DAY


PERFORMANCE
Performance capabilities range from 500 cfm to 25,000 cfm and up to 5 in. wg of static pressure.

SWB SERIES 100

Greenhecks Model SWB Series 100 backward-inclined utility fans are available in seven sizes (110 - 124) with capacities from 500 to 10,000 cfm and static pressures to 2.5 in. wg. Blower scroll constructed of Galvanized steel Drive frame is coated with Permatector Aluminum wheel Clockwise and counterclockwise wheel rotation

SWB SERIES 200

Greenhecks Model SWB Series 200 backward-inclined utility fans are available in thirteen sizes (210 - 236) with capacities from 500 to 25,000 cfm and static pressures to 5 in. wg. Entire fan is constructed of steel and is coated with Permatector Larger shafts, bearings, and increased material thickness Steel wheel Clockwise and counterclockwise wheel rotation

Greenheck Fan Corporation certifies that the SWB fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.

72

UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

Centrifugal Utility Fans - SWB


Model SWB Arrangement 10, single-width, backwardAll structural steel parts are phosphatized and coated with inclined, utility fans feature: Greenhecks Permatector for a long lasting finish.

FINISH

WHEELS

INLET CONES

Backwardinclined wheels are constructed of heavy-gauge, single-thickness blades securely riveted or welded to a heavy-gauge backplate and wheel cone. Each wheel is statically and dynamically balanced to precise tolerances.

The streamlined inlet cone design provides a low turbulence air intake. This reduces intake losses and sound levels.

HOUSING

Utility fan housings are constructed of heavy-gauge steel. Series 100 housings are constructed from galvanized steel. Series 200 fans are constructed of steel and are coated with Permatector. They are available in CW or CCW rotation and are field rotatable to the eight standard discharge positions. Housing sides are bonded to the fan scroll with an airtight lock seam. Housing supports are constructed of structural steel with formed flanges for extra strength. Rugged welded steel drive frame members support the shaft and bearings and provide rigid reinforcement for the housing. A pivoting motor plate with adjusting screws make belt tensioning a quick and easy operation. Prepunched mounting holes are provided for ease of installation.

HOUSING SUPPORTS AND DRIVE FRAME

DRIVES

Drives are sized for a minimum of 150% of driven horsepower. Machined cast iron motor pulleys are factory set to the required RPM and adjustable for final system balancing.

OPTIONS AND ACCESSORIES


SWB 100 SWB 200 OPTIONS AND ACCESSORIES n n n n n n n n n n n n n n n n n n n n n STD n n n n n n n n n n n n n n Vibration Isolators Weatherhood Belt Guard Gravity and Motorized Dampers Model WD (In Stock) External Inlet Vane Damper & Companion Flange Shaft Seal with Aluminum Rub Ring Inlet and Outlet Guards Heat Slinger Drain Connection Access Doors - Bolted Access Doors - Hinged Flanged Inlets or Outlets Dual Drives Aluminum Wheel UL/cUL 705 Electrical with Weatherhood UL/cUL 762 Grease - Indoor and Outdoor Mounting Performance Baffles Welded Scroll Construction Extended Lube Lines Stainless Steel Shaft Greenheck Coatings (See coatings page 119) Aluminum Construction UL Listed for Emergency & Smoke Control
UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

MOTORS

Heavy duty ball bearing motors are carefully matched to the fan load. Open drip proof, totally enclosed and explosion-proof enclosures are available.

SHAFTS AND BEARINGS

Precision turned, ground and polished solid steel shafts are sized so the first critical speed is at least 25% over the maximum operating speed. Stainless steel shafts are available on Series 200 SWBs. Heavy duty, self aligning pillow block ball bearings are selected for a minimum L50 life in excess of 200,000 hours at maximum cataloged operating conditions.

STANDARD CONSTRUCTION FEATURES


SWB 100 SWB 200 STANDARD FEATURES n n n n n n n n n n n n n n n n HOUSING: Heavy-gauge steel housing with lock formed seams Unit support angles with prepunched mounting holes Adjustable motor plate Corrosion-resistant fasteners Slip Fit Outlet BEARINGS, SHAFT AND WHEEL: Heavy duty lubricatable, selfaligning ball bearing pillow blocks Polished, solid steel shafts Backward-inclined steel wheel (sizes 212 through 236) Backward-inclined aluminum wheels

n n

73

Centrifugal Utility Fans - SWB


SWB STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA
MODEL
SWB-110 SWB-113 SWB-115 SWB-116 SWB-118 SWB-120 SWB-124

A
2312 2518 2814 3038 34 37 4112

F
934

H
11 14 1578 1712 1914 2118 2578

MIN/MAX CFM
500 1200 2000 700 1800 2700 1000 2200 3500 1200 2800 4800 1500 3260 5500 1800 3600 6300 2800 5600 8800

2658 183/4 1678 1512

3114 2338 1878 163/4 1058 3434 2534 2118 1812 1158 3818 42 46 28 3078 2278 1912 1234 25 22 1418

3358 2738 2334 1538 25 19

5734 4058 3358

898 1631 2571 767 1496 2154 737 1294 1956 625 1164 1903 545 940 1491 471 723 1151 413 668 989

PERFORMANCE IN INCHES WG .25 .5 1 1.5 2 2.5


1094 1759 2652 939 1591 2228 880 1388 2024 751 1237 1953 667 1016 1544 591 807 1207 503 727 1030 1983 2176 2351 2511 1767 1928 2073 2211 2356 1557 1704 1835 1954 2150 1368 1492 1606 1709 1141 1255 1373 1478 1640 943 1069 1184 1287 1316 827 917 1005 1108 1178

D E F

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

SWB STANDARD CONDENSED PERFORMANCE & DIMENSIONAL DATA


MODEL SWB-210 A 22 B C D E F 814 958 H 11 13 14 1578 171/2 1914 2118 23 2578 2812 3134 3478 3812 2658 1834 1678 1512

SWB-212 22910 2838 2138 1678 1512

SWB-213 2518 3114 2338 1878 1634 1058 SWB-215 2814 3434 2534 2118 1812 1158 SWB-216 3038 3818 SWB-218 SWB-220 34 37 42 46 28 3078 2278 1912 1234 25 22 1418

3358 2738 2334 1538 24 25 27 27 29 30 17 19 21 2338 2514 2814

SWB-222 3958 5212 3678 3012 SWB-224 4112 5734 4058 3358 SWB-227 46 6118 4434 3758 68 75 4834 4118 5512 4418

SWB-230 4814 SWB-233 52

SWB-236 5538 8238 6078 4858

n Performance for available in stock sizes is shown on page 75 D PERFORMANCE IN INCHES WG STOCK MIN/MID SIZES (n) MAX/CFM .5 1 2 3 4 5 625 1158 1501 1250 1770 1968 2317 2657 3003 3326 n 2375 3096 3201 600 1020 1372 1650 1775 1943 2262 2569 2868 3147 n 3100 3108 3199 1000 998 1287 2200 1680 1821 2085 2346 2615 2876 3800 2729 2817 1200 886 2575 1447 1580 1829 2079 2329 4700 2460 1200 762 3300 1359 1472 1696 1919 2143 2348 n 5700 2208 2279 2000 762 963 3600 1117 1233 1459 1682 1888 2069 7000 2003 2067 2000 647 860 4600 1072 1171 1365 1556 1754 1930 n 8500 1846 1904 2500 602 783 4550 841 952 1173 1370 1554 1733 10000 1539 1596 1703 3000 526 7200 914 992 1138 1282 1424 1573 n 12000 1440 1486 4000 495 648 8350 799 872 1012 1167 1307 1430 14000 1259 1303 1391 4000 418 12000 816 873 985 1090 1195 19000 1238 1274 6000 402 508 13000 661 720 828 933 1035 1132 21000 1006 1044 1119 7000 361 472 13000 520 586 703 820 945 27000 978 1010 1069

O.D.

All dimensions in inches. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

74

UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

Centrifugal Utility Fans - SWB


SWB PERFORMANCE DATA - IN STOCK
stock Model sWB fans come with cW-tH rotation and discharge and include: aluminum wheel (sWB-210), steel wheel (sWB-212-224), weatherhood and UL/cUL 705. MODEL RPM 1670 1833 2103 2408 2650 3033 3339 1500 1651 1770 1891 2029 2169 2265 2376 2486 2600 2716 2857 2998 919 982 1124 1287 1347 1416 1526 1621 1705 1784 1905 2042 2200 734 815 876 934 980 1028 1100 1176 1230 1295 1395 1482 1622 1757 1942 614 681 715 749 799 858 895 944 1014 1080 1175 1281 1514 HP 4 1 3 1 2 3 4 1 112 2 1 4 1 3 1 2 1 2 3 4 3 4 1 1 112 112 112 2 2 1 4 1 3 1 2 3 4 1 1 112 112 2 2 3 3 5 1 3 1 2 3 4 3 4 1 1 112 112 2 2 3 3 5 5 712 1 2 3 4 1 1 112 112 2 2 3 3 5 5 712
1

MAX BHP .25 .33 .50 .75 1.0 1.5 2 .251 .334 .414 .501 .612 .751 .863 1.001 1.150 1.316 1.501 1.740 2.001 .270 .334 .501 .752 .861 1.001 1.252 1.503 1.748 2.003 2.439 3.004 3.756 .307 .502 .621 .752 .869 1.003 1.228 1.501 1.718 2.004 2.506 3.004 3.939 5.007 6.76 .550 .753 .870 1.002 1.216 1.506 1.709 2.005 2.482 3.003 3.867 5.011 8.22

SWB-210-LMDX-QD

SWB-212-LMDX-QD

SWB-216-LMDX-QD

SWB-220-LMDX-QD

SWB-224-LMDX-QD

.25 1246 1383 1608 1860 2059 2372 2621 1443 1606 1734 1867 2017 2169 2273 2392 2509 2629 2751 2899 3047 2212 2396 2805 3267 3435 3628 3933 4195 4426 4643 4974 5348 5778 3125 3551 3860 4156 4389 4631 4991 5369 5636 5956 6447 6872 7554 8209 9107 4782 5420 5739 6057 6516 7050 7384 7824 8449 9037 9878 10813 12865

.5 1158 1307 1542 1801 2004 2322 2576 1323 1504 1645 1786 1940 2092 2196 2315 2434 2559 2686 2840 2992 1925 2140 2599 3092 3267 3468 3786 4057 4295 4519 4858 5240 5678 2675 3179 3527 3856 4113 4366 4742 5136 5414 5746 6253 6690 7389 8056 8971 4133 4878 5236 5589 6093 6664 7019 7485 8143 8758 9623 10580 12661

.75 1046 1214 1471 1744 1952 2277 2533 1185 1388 1538 1685 1851 2016 2128 2257 2377 2501 2627 2779 2930 1359 1773 2352 2897 3089 3307 3639 3917 4163 4392 4740 5031 5576 1550 2653 3114 3499 3779 4061 4475 4903 5195 5536 6056 6505 7220 7920 8834 2995 4198 4631 5028 5592 6227 6614 7120 7807 8442 9345 10339 12463

PERFORMANCE IN INCHES WG 1 1.5 2 922 1108 737 1388 1198 788 1680 1528 1359 1900 1775 1629 2231 2135 2023 2491 2408 2315 990 1252 1421 1048 1583 1313 1757 1544 1170 1928 1742 1490 2044 1871 1655 2176 2016 1833 2306 2153 1986 2440 2293 2140 2574 2434 2293 2730 2603 2470 2884 2770 2643

2.5

1111 1469 1894 2209

1237 1764 2092

1385 1842

1298 1574 1772 1962 2132 2326 2513

1435 1718 1929 2164 2367

1620 1975

1996 2676 2887 3117 3473 3774 4034 4267 4621 5019 5474

2284 2634 3092 3438 3721 3980 4368 4800 5270

2153 2976 3347 3652 4083 4537 5045

3191 3737 4257 4800

3231 3904 4529

3732

2994 3368 3709 4174 4625 4937 5308 5866 6323 7051 7746 8692

3242 3934 4342 4781 5398 5906 6703 7439 8407

3994 4832 5433 6300 7083 8128

2781 4779 5842 6706 7792

5223 6262 7451

6597

3650 4299 5013 5726 6151 6692 7435 8118 9054 10072 12262

3775 4874 5671 6583 7349 8401 9512 11811

5222 6263 7650 8870 11343

6650 8150 10813

7188 10240
UL/cUL 705 UL/cUL 762 E40001-SWB

8849

Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories).

For complete product information refer to the CAPS program or to catalog Centrifugal Backward-Inclined - Model SWB Utility Fans, or contact your local representative.
UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

75

Centrifugal Fans - Selection Guide


FAN WIDTH
SINGLE-WIDTH (SW) Single-Inlet - Single-Outlet Used in a wide range of applications Contaminated air, elevated temperatures, moisture content, kitchen exhaust, fume exhaust Typically used in ducted in - ducted out applications, but can be unducted at either end as needed DOUBLE-WIDTH (DW) Double-Inlet - Single-Outlet Generally used for high volume applications or air handlers Clean air applications only due to bearings being located in the airstream Typically applied as free inlet - ducted outlet

ROTATION

Choice between clockwise (CW) and counterclockwise (CCW) as determined from the drive side. Rotation changes discharge location as illustrated below.

SPARK-RESISTANT CONSTRUCTION
SPARK C - Includes aluminum inlet cone and rub ring SPARK B - Includes aluminum wheel and rub ring SPARK A - All airstream parts constructed from aluminum (Consult factory for availability)

CCW

CW

MOTOR POSITIONS (ARR 1 & 3 ONLy)

ARRANGEMENTS
SInGLE-WIDTH Backward-inclined or Airfoil Wheel

ARRANGEMENT 10

This is the most common fan Motor position and fan rotation are arrangement. Motor is mounted DISCHARGE POSITIONS determined from Chart shows discharge positions available on QB on the fan under the bearing from side pedestal and can be enclosed centrifugal fans. Determined drive the drive side. Some models and sizes allow for field rotation. with a motor cover, limited motor frame sizes, smallest overall package size. No mounting base required.
BH BAU UB TAU TH

Motor position determined from the drive side. Letter assignment is independent of discharge position and fan rotation.

FAN Z Y X W

SInGLE-WIDTH Backward-inclined or Airfoil Wheel

ARRANGEMENT 9

Motor is mounted on the side of the bearing pedestal, limited motor frames sizes, smaller overall size than arrangement 1. No mounting base required.

WHEEL TyPES

SInGLE-WIDTH Backward-inclined or Airfoil Wheel

ARRANGEMENT 1

FAN Z Y X W

Motor is mounted on a structural base. Mounting base required. See page 118 for more details.
ISOLATION BASE

Backward-inclined Wheel Centrifugal, non-overloading style with single-thickness flat blades. Most versatile wheel. Excellent for clean, high-temp, or contaminated air. Airfoil Wheel Centrifugal, non-overloading style with Airfoil shaped blades. Higher operating efficiencies. Used for clean air applications.

Motor position and fan rotation are determined from drive side

SInGLE-WIDTH AnD DOUBLE-WIDTH Backward-inclined or Airfoil Wheel

ARRANGEMENT 3

Z Y

FAN X

Motor position and fan rotation are determined from drive side

ISOLATION BASE

SINGLE WIDTH

DOUBLE WIDTH

DW (when compared to SW) can supply an equal amount of air with a smaller wheel diameter resulting in lower overall unit size. Bearing located in the airstream limits temperatures and does not permit sparkresistant construction. Mounting base required. See page 118 for more details.

Industrial Process Open Wheel Open material handling wheels are suitable for material handling such as wood chips, abrasives and dust. Industrial Process Wool Wheel The wool wheel, or backplate material handling wheel, is designed for handling long, fibrous, stringy material such as paper or yarn. Industrial Process Air Handling Wheel Air handling wheels are designed for applications ranging from clean air exhaust to light material handling.

76

UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

Centrifugal Fans - Series 21 & 41-BISW/AFSW/BIDW/AFDW


Greenheck centrifugal fans are designed for clean or contaminant ventilation applications up to 200F. Units can be mounted (both indoor or outdoor) in ducted inlet and/or ducted outlet installations such as exhaust air, supply air, filtration, comfort conditioning, light industrial processes, fume exhaust, fluid bed pressurization and combustion air.

SERVICE CHART
Centrifugal Fans - All Models through size 54, Arrangements 1, 3, 9, 10 - Class I, II

10 DAY

PERFORMANCE
Performance capabilities available on QB range from: 1,400 cfm to 50,000 cfm for AFSW 50 cfm to 48,000 cfm for BISW 3,000 cfm to 95,000 cfm for AFDW 1,300 cfm to 94,000 cfm for BIDW Up to 81/2 in. wg of static pressure.

STANDARD CONSTRUCTION FEATURES


AMCA Certified for Sound and Air Performance Permatector coating Final assembly vibration analysis Minimum bearing life of L(10) 80,000 hours {Average Life - L(50) of 400,000 hours} Rotatable housings (sizes 7 - 30) Arr. 1, 9 and 10 Available in arrangements 1, 3, 9 and 10 (See page 76)

SERIES 21 PERMALOCK HOUSINGS


Fan sizes 7-49, Class I and II feature Greenhecks exclusive air-tight PermaLock seam. This seam provides a structural bond between the side panels and scroll wrap.

OPTIONS AND ACCESSORIES


Bolted or hinged access doors Copper lube lines Extended life bearings Drain connection Inlet, outlet flanges and guards Companion flanges Totally enclosed belt guard (w/GFC supplied motor & drives) Totally enclosed shaft guard Structural base or motor slide base (Arr. 1, 3)* Shaft seal (Arr. 1, 9, 10) Spark-resistant Type B Construction Spark-resistant Type C Construction UL/cUL - 705 (Electrical) UL listed Power Ventilators for Smoke Control Systems Weatherhood (Arr. 10) Neoprene isolators (sizes 7 - 30, Arr. 10, Class I only) Spring isolators (sizes 7 - 30, Arr. 10, Class I only) Greenheck coatings (See coatings page 119) * Arrangement 1 & 3 must be mounted on Isolation Base. See Greenheck Structural Base page reference 118 for more information.

Fan sizes 7-73 in Class I and II and sizes 12-73 in Class III feature fully welded housings.

SERIES 41 WELDED HOUSINGS

WHEEL TyPES
Backward-inclined Wheel Centrifugal, non-overloading style with single-thickness flat blades. Most versatile wheel. Excellent for clean, high-temp, or contaminated air. Airfoil Wheel Centrifugal, non-overloading style with Airfoil shaped blades. Higher operating efficiencies. Used for clean air applications.

For complete product information refer to catalog Centrifugal FansSeries 21 and Series 41 and the Single-Width Centrifugal Fan Performance Supplement and the Double-Width Centrifugal Fan Performance Supplement, or contact your local representative.

AMCA Licensed Sound and Air Performance can be found in Greenheck Fan Corporations supplements: Single-Width Cent Fan Supp R Rev 1 February 2004 and Double-Width Cent Fan Supp Rev 1 July 2004.

UL/cUL - 705 UL Listed Power Ventilators for Smoke Control Systems UL/cUL - 762 UL Listed Restaurant Exhaust (BISW)
UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

77

Industrial Fans - Open and Radial Tip - IPO/IPW/IPA


Greenheck industrial fans are engineered and built for reliable operation in harsh environments where high static pressures and material handling requirements are encountered. Three wheel types are offered: Model IPO - Open Radial, Model IPW - Wool (Backplate), and Model IPA - Air Handling.

SERVICE CHART
IPA, IPW & IPO - Sizes 5-19 Arrangements 1, 9, and 10

10 DAY

PERFORMANCE
Performance capabilities available range from: 50 cfm to 20,000 cfm for IPO 50 cfm to 20,000 cfm for IPW 100 cfm to 22,000 cfm for IPA Up to 22 in. wg of static pressure.

STANDARD CONSTRUCTION FEATURES


AMCA Certified for air performance Permatector coating Final assembly vibration analysis Minimum bearing life of L(10) 80,000 hrs {Average life - L(50) of 400,000 hours} Fully welded scroll housing Fully welded heavy-gauge steel wheel Rotatable housing Available in arrangements 1, 9, 10 (see page 76)

IPW WHEEL The wool wheel or backplate material handling wheel is designed for handling long, fibrous, stringy material.

OPTIONS AND ACCESSORIES


Bolted access door Drain connection Extended lube lines Inlet, outlet and companion flanges Totally enclosed belt guard Inlet, outlet and shaft guards Shaft seal Weatherhood (Arrangement 10) Greenheck coatings (See coatings page 119) Structural base or motor slide base* Neoprene or spring isolators
* Arrangement 1 only must be mounted on Structural Base/Platform. See Greenheck Structural Base page reference 118 for more information.

IPO WHEEL Open material handling wheels are suitable for most industrial requirements.

IPA WHEEL Air handling wheels are designed for applications ranging from clean air exhaust to light material handling.

AMCA Licensed air performance can be found in Greenheck Fan Corporations supplement: Industrial Process Fan PM October 2002.

For complete product information refer to catalog Industrial Fans and Industrial Fans Performance Manual, or contact your local representative.

78

UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

Plenum Fans - QEP


Greenheck plenum fans are designed for clean air handling applications where the fan operates unhoused within a pressurized plenum with airstream temperatures up to 200F. The compact size of the plenum fan makes it an excellent selection for retrofit and replacement applications and in variable air volume systems.

SERVICE CHART
QEP - Class I & II

10 DAY

STANDARD CONSTRUCTION FEATURES


AMCA Certified for Sound and Air Performance Permatector coating Final assembly vibration analysis Minimum bearing life of L(10) 80,000 hours {Average life - L(50) of 400,000 hours} Airfoil wheel, aluminum 12-Bladed wheel design Heavy-gauge spun inlet cone

OPTIONS AND ACCESSORIES


Inlet collars, flanges, and screens Companion inlet flange Protective cage Totally enclosed belt guard Extended lube line kit Extended life bearings Greenheck coatings (See coatings page 119) Sure-Aire

QEP ON STRUCTURAL BASE (TYPICAL INSTALLATION)

PERFORMANCE
Performance capabilities for units available on QB range from 800 cfm to 60,000 cfm with up to 7 in. wg of static pressure.

MOUNTING

SIZE 12 - 30

CLASS I,II,III I,II III I,II I,II I,II I,II I,II I II

ARRANGEMENT 1 3 3 1 3 1 3 1 3 3

Horizontal*

18 - 54 18 - 49

TYPICAL INSTALLATION
RADIAL
I AX AL

Horizontal Motor on Frame (Top)

12 - 16 18 - 54 12 - 16 18 - 54 12 - 16

Horizontal Motor on Frame (Side)

RAD

Vertical Motor on Frame (Side)

18 - 54 18 - 36

IAL
RAD

A XI

IAL

* Arrangement 1 & 3 units with horizontal mounting must be mounted on Structural Base/Platform.

For complete product information refer to catalogs Plenum Fans Models QEM & QEP, or contact your local representative.

AMCA Licensed Sound and Air Performance can be found in Greenheck Fan Corporations QEM & QEP, Rev. 1, September 2008.

UTiliTy, CENTRiFUgAl AND RADiAl blOwERS

79

Laboratory Exhaust Systems

Vektor-H

Family of Lab Exhaust Systems


Vektor-H

Housing Style Stack Style Min Flow Max Flow Max ESP

Inline Centrifugal High Plume Nozzle 270 CFM (850 m/hr) 24,000 CFM (40,750 m/hr) Up to 3.5 inches wg (875 Pa)

Why use Greenheck Vektor Lab Exhaust Systems?

The main objective of a laboratory exhaust system is to remove hazardous or noxious fumes from a laboratory, dilute the fumes as much as possible and expel them from the lab building so that the fumes do not contaminate the roof area nor are re-entrained into the building makeup air system. Greenheck Vektor laboratory exhaust systems offer the following benefits: Significant plume rise without unsightly exhaust stacks that detract from buildings aesthetics Significant dilution of laboratory exhaust effluent, reducing contaminant concentration Inline or side inlet centrifugal arrangements Reliable belt or direct drive systems Efficient and quiet blower technology Application to constant or variable volume exhaust systems Efficient discharge nozzle design Safe and easy maintenance Multiple fan assemblies on a factory provided common plenum Meets ANSI Z9.5, NFPA-45, and ASHRAE lab design guidelines Energy Recovery options available

How Vektor High Plume Dilution Technology Works...


Laboratory exhaust is drawn into the Vektor fan (A). The exhaust is discharged into the Vektor multistage induction nozzle and ambient dilution air is induced into the Vektor windband (B). The laboratory exhaust plus induced dilution air is discharged at high velocity to atmosphere (C). Available on the Vektor-MD and Vektor-CD.

80

lAbORATORy EXHAUST SySTEMS

Vektor-H
Vektor-H models use a tapered outlet nozzle to accelerate the exhaust to a high velocity. This provides the exhaust with additional momentum for displacement high above the roof. Because the Vektor-H is a curb-mounted unit, installation time is reduced by eliminating costly field fabricated inlet and outlet duct. The optional bypass air plenum and damper accommodates constant and variable volume laboratories.

SERVICE CHART
Vektor-H all models
Isolation Damper Bypass Air Damper

15 DAY

STANDARD LEAD TIME

Vektor-H is listed for Electrical (UL/cUL 705) E40001

Bypass Air Plenum

PERFORMANCE
Performance capabilities 270 cfm to 24,000 cfm and up to 3.5 in. wg of external static pressure.

Bypass Air Laboratory Exhaust

Vektor-H is listed for Grease Removal (UL/cUL 762) Power Ventilators for Restaurant Exhaust Applications E40001

Optional bypass air plenum shown

Greenheck Fan Corporation certifies that the Model Vektor-H lab exhaust fans shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The Ratings Seal applies to Sound and Air Performance as shown in the Vektor-H Performance Rev. 1 November 2005 catalog.

STANDARD CONSTRUCTION FEATURES


Galvanized steel construction LabCoat two-part electrostatically applied coating AMCA Certified Sound and Air Performance Belt drive configuration Designed and guaranteed to withstand 125 mph wind load ratings Constant speed drives Premium efficient, totally enclosed fan cooled motors, Class F insulation, VFD compatible Spark-Resistant Type B construction L(10) 100,000 hr. bearings Aluminum wheel and shaft seal

OPTIONS AND ACCESSORIES


NEMA-3R disconnect Roof curb (12, 18, or 24 high) Bypass air plenum (bottom or side inlet) UL 762 rating for grease applications Factory mounted actuators (manual or electric) Isolation dampers Bypass dampers

FAN SIZE 9 Min CFM Max CFM Plume Rise @ 3000 fpm (ft.) (min) (max) 270 1760 14 19 10 420 1760 15 19 12 600 2640 16 20 13 810 3160 17 21 16 1050 7080 18 25 18 1320 7880 19 26 22 1650 10560 20 30 24 2760 14760 22 33 30 3690 19640 24 37 36 5310 24000 26 42

Performance certified is for installation type A: Free Inlet, Free outlet. Performance ratings do not include the effects of appertrnances (accessories). Power rating (Bhp) does not include transmission losses. Plume rise calculated assuming a 10 mph crosswind. 3,000 ft/min is the minimum recommended outlet velocity per ANSI Z9.5. For a full range of fan performance, consult the Laboratory Exhaust Systems, Vektor-H Performance Supplement. (Vektor-H Performance Rev. 1 Nov. 2005)

For complete product information refer to the CAPS program or to catalog Vektor-H, or contact your local representative.

lAbORATORy EXHAUST SySTEMS

81

Kitchen Ventilation
Type I Hoods
Type I hoods are used for collecting and removing grease vapors and smoke. They are available in wall, double-island and single-island styles. MODEL G __ __ __ CAnOPy HOOD

SErvicE chart
All hoods are available in 5 or 10 days depending upon the accessories chosen.

(Filter) (Supply) (Style) For model designation add the appropriate suffix, i.e. GHEW Filter type q G - Grease Grabber q X - Grease-X-Tractor q H - Baffle q K - High Velocity Cartridge Supply q Exhaust Only q Face q Combination Face & Air Style q Wall q V-Bank (Single-Island) q UL/cUL Listed without Fire Damper

STANDArD FEATUrES
UL/cUL Listed and NSF Certified 18 Ga. 304 SS or 430 SS construction Integral 3 in. airspace for clearance to limited combustibles

5 DAy ACCESSOrIES
Light / Fan switches, hood or remote mounted Duct collars shipped loose (factory attached std.) Filler panels for clearance to limited combustibles Enclosure panels to span between hood and ceiling Kitchen fan control center

Style

Wall Style

Single-iSland V-Bank

10 DAy ACCESSOrIES
Stainless steel backsplash panel, (non) insulated End skirts for improved capture and performance Insulated supply plenum Exhaust air balancing baffle Fire cabinet - utility cabinet Fire suppression system - full or prepiped Trim strips

E xhaust Only
Sizes Available Length Width Height 36 in. to 192 in. 39 in. to 60 in. 24 in. or 30 in.

E xhaust Only
Sizes Available Length Width Height 36 in. to 192 in. 48 in. to 78 in. 24 in. or 30 in.

Filter Types
The Grease Grabber (stainless steel) two-stage filtration system is utilized in conjunction with the Grease-X-Tractor to be 80% efficient. UL/cUL 1046 Classified and NSF Certified. The Grease-X-Tractor high efficiency stainless steel or aluminum filters have twice the grease extraction capability of a baffle filter. The filters shall be UL/cUL 1046 Classified and NSF Certified. Aluminum or stainless steel baffle type are the traditional choice for inexpensive grease removal. The filters shall be UL/cUL 1046 Classified. The high velocity stainless steel cartridge filters offer dry cartridge performance with lower cost. The filters shall be UL/cUL 1046 Classified and NSF Certified.

Supply Plenums internal


Face Supply hood(s) full compensating model with the capability to replace exhausted air with outside air.

external

Air Curtain Supply Plenum introduces air in a downward pattern that contains contaminated air while providing cooling to the cooks. Back Supply Plenum introduces air below and behind the cooking equipment allowing air to rise and mix with room air.

Variable Supply Plenum distributes air out into the kitchen through the face and/ or introduces air down onto cooking personnel through thecurtain.

82

Kitchen Ventilation SyStemS

Type II Hoods
Type II hoods are used for collecting and removing steam, vapor, heat and odors. They are used for non-grease applications including heat and condensate hood models.

SErvicE chart
GO, GD1, GD2, GD3

5 10 daY daY 3 3

Model gd1

Condensate Hood, no Baffles


The GD1 Hood is designed for light condensate applications. The lack of baffles means the duct collar can be freely positioned - a design plus.

Model gd3 Model gd2

Condensate Hood, 2 Baffles


The GD3 Hood is designed for heavy condensate applications. The baffles catch and drain all moisture - no drips.

Condensate Hood, 1 Baffle


The GD2 Hood is designed for moderate condensate applications. With one baffle, the duct collar position can be adjusted.

Model gO
Oven Hood
The GO Hood is designed to capture heat and vapor, creating a more comfortable environment for the cooking staff.

The Complete Solution in 10 Days or Less


Greenheck is a single-source manufacturer of a complete, flexible kitchen system. Our patented methods of grease extraction are some of the most efficient in the industry, resulting in energy savings and low maintenance costs.

What products make up a complete kitchen system at Greenheck?


3 1 2 4 2 3

kitCHen HOOdS - See pages 82-83 Make-up air unitS eXHauSt FanS kSFd, kSFB, dgk, dgX, ig, igX - See pages 86-91 CuBe - See pages 14-17 CWB - See pages 19-21 SWB - See pages 72-75 tCB - See page 56

rOOF CurBS & eXtenSiOnS - See pages 38-39

Greenheck Kitchen Hoods are built-in accordance with the following codes, standards, and recommended practices. UL/cUL 710 Listed NSF NFPA 96 SBCCI BOCA IMC

codE information

Kitchen Ventilation SyStemS

83

Energy recovery Ventilators


Energy recovery Ventilators - ErV
Energy recovery ventilators precondition outdoor air to near room conditions. Fresh outdoor air flows through one side of the unit, while stale exhaust air from the building flows through the other side. An energy recovery wheel rotates between the two airstreams, transferring temperature and moisture properties. In the summer, this transfer reduces the temperature and moisture level of the outdoor air. Likewise in the winter, this transfer increases the temperature and moisture of the outdoor air. The overall effect is a significant reduction in the amount of energy used to condition the outdoor air. All ErV models can be roof mounted or mounted indoors for clean air applications up to 130F. Energy recovery ventilators are primarily used in institutional and commercial air conditioned applications. Arrangement B Outdoor Air Discharge B

SErvicE chart
A D

10 daY
3

ErV All Models

PErFOrMANCE
E Performance capabilities 500 cfm to 6000 cfm and up to 11/2 in. wg of external static pressure.

Exhaust Air Inlet

Intake Hood Exhaust Hood

ErV DIMENSIONAL DATA STANDArD CONSTrUCTION FEATUrES


Galvanized steel construction AMCA Certified Air Performance Total enthalpy wheel certified to ARI Standard 1060 1 in. foil face insulation Forward-curved blowers Single-point wiring Motor starters Nonfused disconnect
MOdel erV-251 erV-361 erV-521 erV-581 EXTErIOr DIMENSIONS A 46 62 67 75 B 34 51 67 70 C 27 34 44 67 D 12 18 16 16 E 8 15 15 22 WEIGHT (LBS.) 340 860 1290 1470 CUrB OUTSIDE DIMENSIONS 421/2 x 301/2 581/2 x 471/2 631/2 x 631/2 713/4 x 66

All dimensions in inches.

OPTIONS AND ACCESSOrIES


Fresh air & exhaust air filters, 2 in. pleated (30% eff.) Supply & exhaust dampers Roof curbs Listed to UL-1995 (open motors only) Enthalpy sensor (Economizer) Temperature sensor (Economizer) Timed exhaust frost control Duct flanges Hinged access doors (361, 521, 581 only) Weatherhood Dirty filter sensor Service outlet Permatector

BENEFITS FOr BUILDING OCCUPANTS AND OWNErS


Humidity control Reduced latent load on air conditioning equipment Improved indoor air quality of building Increased comfort of building occupants Reduced ventilation costs by as much as 75% producing year round energy savings Eliminates problems associated with high indoor moisture levels

APPLICATION OF ErVs
Energy recovery technology is well suited for commercial and institutional applications such as classrooms, offices, meeting rooms, condominiums and assisted living facilities.

For complete product information refer to catalog Model ERV, Energy Recovery Ventilators, or contact your local representative.
84
eneRGy RecoVeRy VentilatoRS

Energy recovery wheels certified by the AHrI Air-to-Air Energy recovery Ventilation Equipment Certification Program in accordance with AHrI Standard 1060. Actual performance in packaged equipment may vary. Certified ratings are available in the Certified Product Directory.

Greenheck Fan Corporation certifies that the ErV models shown herein are licensed to bear the AMCA seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certified ratings Program.

Energy recovery Ventilators - ErV

SErVICE AND MAINTENANCE


ErVs are engineered for minimal maintenance and have numerous panels for easy access to internal components requiring maintenance. Outdoor air and exhaust airstreams typically have throwaway filters that need to be replaced on a regular schedule. The energy wheel is segmented and slides out to allow personnel to transport the wheel segments to a convenient location for cleaning. While the wheel should be checked annually, cleaning is required only once every 2-3 years, and mild detergent and water is all that is required.

Outdoor Air 91F

Preconditioned Outdoor Air 79F

Energy Recovery Ventilator

AHU

Supply 55F

Exhaust Air 87F

Exhaust Air 75F

Return Air 75F

Energy recovery Ventilators - MiniVent 450 & 750


The MiniVent is an energy recovery ventilator for commercial and institutional applications that require 300 cfm to 800 cfm of ventilation air. The compact design provides an economical solution for individual spaces, such as school classrooms and small offices. The MiniVent is designed for indoor installations and may be floor mounted or ceiling hung. A removable panel enables easy access to filters and enthalpy wheel. A B

SErvicE chart

STANDArD CONSTrUCTION FEATUrES


Galvanized steel construction Total enthalpy wheel certified to AHRI Standard 1060 Forward-curved blower Single-point wiring 1 in. pleated filters Insulated Listed to UL-1995

in StocK
3

10 daY
3

MiniVent-450, 750

PErFOrMANCE
Performance capabilities 300 cfm to 800 cfm and 1 in. wg of external static pressure.

ACCESSOrIES
Intake and exhaust accessories GRS and GRSF (see page 36) Wall mount accessories BV-Brick Vent and WC-Wall Cap Speed control Motion detector (MiniVent 450 only) Hanging vibration isolator kits

MINIVENT DIMENSIONAL DATA


MOdel 450 750 EXTErIOr DIM. A 40 46 B 29 36 C 20 22 WEIGHT (LBS.) 150 210

All dimensions in inches.

For complete product information refer to catalog Model MiniVent or contact your local representative.

eneRGy RecoVeRy VentilatoRS

85

Make-Up Air Systems


Direct Fired Gas - Make-Up Air Systems - DGK/DG/DGX
The Greenheck models DGK, DG and DGX are designed to provide heated make-up air for commercial and industrial applications. The direct gas-fired burner provides a 100% efficient heating system with an ETL label. Airflow capacities up to 15,000 cfm and heating capacities up to 1,600,000 Btu/Hr are available. Installation may be stand-alone or on a combination package with exhaust fan on a common curb.

SErvicE chart
DGK - Housing 15 DG - Housings 10, 20, 30 DGX - Housings 12, 22, 32

3 5 daY daY
3 3 3

10 daY
3 3 3

OPTIONS AND ACCESSOrIES


dgk n n n n n n dg n n n n n n n n n n n n n n n dgX n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n OptiOnS and aCCeSSOrieS Insulated Housing Air Filter Gauge Intake Dampers Gas Pressure regulator Fiberglass Insulation Inlet Air Sensor Combination Curb Extension roof Curbs Duct Adaptor Weatherhood Propane Gas Freezestat Discharge Diffuser Double-Wall Construction Exhaust Fan Starter Variable Volume recirculation Thru-Wall Mounting Evaporative Cooling remote Control Panels 115 volt Service receptacle Discharge Temperature Control room Override room Temperature Control DDC Interface

PErFOrMANCE
Performance capabilities are 15,000 cfm with up to 2 in. of wg of static pressure.

STANDArD CONSTrUCTION FEATUrES


Galvanized steel construction Control center with starter and disconnect Vibration isolation Factory wired and tested ETL label V-bank filters (DG & DGX)

n n n

The evaporative cooling section includes a galvanized steel housing with a louvered intake, 2-inch aluminum mesh filters and a stainless steel evaporative cooling module. The evaporative cooling media is Munters GLASdek and has a depth of 12 inches for 90% cooling effectiveness. The entire section mounts directly to the front of the unit, eliminating transition or ductwork by others.

OPTIONAL EVAPOrATIVE COOLING (DG & DGX)

OPTIONAL rEMOTE PANEL


remote panels feature a variety of control switches and indicator lights mounted on a Permatector coated galvaneal steel box.
Direct Fired Gas Heat

For complete product information refer to catalog Model DGK, Model DG or Model DGX, or contact your local representative. For roof opening dimensions and locations refer to the factory submittal/IOM.
86
maKe-Up aiR

Direct Fire Gas - Models DGK/DG/DGX


COMBINATION PACKAGES - DG/DGX
DGX Dimensions
The Greenheck combination kitchen package simplifies installation and reduces field labor costs. The pre-engineered design ensures that the supply fan, exhaust fan, curb and combination extension components interface properly. Equally important, Greenheck combination packages are specifically designed to comply with NFPA 96.
A max. 10 ft. min. A max.
Housing Size H10 H20 H30 Housing Size H12 H22 H32 arr. dBC a 179 200 225 B 46 54 62 arr. dBC a 171 225 261 B 46 54 62 Width 33 44 52 Width 30 40 52

10 ft. min.

All dimensions are in inches.

Combination package - Arrangement DBC

DGK Dimensions

STAND-ALONE ARRANGEMENTS - DGK/DG/DGX


Model DGK, DG and DGX are available for either downblast (Arrangement DB) or horizontal (Arrangement HZ) discharge. An upblast discharge (Arrangement 10 ft. min. UB) is also available on the DGX.
A max.

DG Dimensions

Housing Size

arr. dB/HZ a 108 B 30 arr. dB/HZ a 131 148 160 B 34 34 42 arr. dB/HZ a 127 160 1920 B 40 46 49 Width 33 44 52 Width 28 36 48 Width 32

H15

DG Dimensions DGX Dimensions


downblast discharge - Arrangement DB Horizontal discharge - Arrangement HZ

Housing Size H10 H20 H30 Housing Size H12 H22 H32

All dimensions are in inches.

DGX Dimensions

THrU-WALL INSTALLATION - DGX


Model DGX is available with a pre-engineered, thru-wall installation option, which is ideal when a roof penetration is not desirable. Factory options that facilitate easy installation and ensure problem-free operation: Weatherhood: A full downturn design with generous intake area to minimize intake velocity and moisture entrainment. thru-Wall Sleeve: Sleeve provides attachment interface between weatherhood and burner section. Accommodates walls up to 15 inches in depth. Filter Section: Aluminum mesh media filters outdoor air and strips fine mist from the air. A drain pan weeps moisture out the front of the wall sleeve.

Housing Size H12 H22 H32

thru-Wall MOunt a 122 145 160 B 40 46 49 Width 33 36 52

All dimensions are in inches.

Consult your representative for dimensional data when the evaporative cooling option is selected. For roof opening dimensions and locations, refer to the factory submittal/IOM.
Thru-Wall Arrangement
maKe-Up aiR

87

Indirect Gas-Fired Make-Up Air - IG/IGX


The Greenheck models IG and IGX feature 80% efficient indirect gas fired furnace(s) that are ETL Listed. Heating capacity ranges from 75,000 to 1,200,000 BTU/hr and airflow volumes are available up to 15,000 cfm.

SErvicE chart
IG - Housings 10, 20, 30 IGX - Housings 12, 22, 32

10 daY
4 4

PErFOrMANCE
Performance capabilities are 15,000 cfm with up to 2 in. of wg of static pressure.

OPTIONS AND ACCESSOrIES


IG IGX
n n n n n n n n n n n n n n n n n n n n

OPTIONS AND ACCESSOrIES Aluminized Steel Heat Exchanger Stainless Steel Heat Exchanger Air Filter Gauge Motorized Damper Exhaust Fan Starter(s) Inlet Air Sensor Evaporative Cooling 115V Service receptacle roof Curb Freezestat Propane Gas Duct Adapter Double-Wall Construction Gas Pressure regulator Mixing Box Evaporative Cooling remote Control Panel(s) Modulation Control (4:1, 2:1 turndown) Staged Control (8:1, 2:1 turndown) DDC Temperature Control

STANDArD CONSTrUCTION FEATUrES


Power vented Galvanized steel construction Control center with starter and disconnect Vibration isolation Factory wired and tested ETL label V-bank filters ETL Listed for Indoor and Outdoor installation to ANSI Standard Z83.8 - 2002 and CGA Standard 2.6 -2002 80% thermal efficiency Electronic staged or modulating gas controls Direct spark ignition system Easy access burner controls Insulated double-wall furnace section construction

n n n n n n n n n n n n n n n n n n

COMBINATION PACKAGES
The Greenheck combination kitchen package (Arrangement DBC) simplifies installation and reduces field labor costs. The pre-engineered design ensures that the supply fan, exhaust fan, curb and combination extension components interface properly. Equally important, Greenheck combination packages are specifically designed to comply with NFPA 96.

STAND-ALONE ArrANGEMENTS
Models IG and IGX are available for either downblast (Arrangement DB) or horizontal (Arrangement HZ) discharge.

OPTIONAL EVAPOrATIVE COOLING


The evaporative cooling section includes a galvanized steel housing with a louvered intake, 2-inch aluminum mesh filters and a stainless steel evaporative cooling module. The evaporative cooling media is Munters CELdek or GLASdek with a depth of 12 inches for 90% cooling effectiveness. The entire section mounts directly to the front of the unit, eliminating transition or ductwork by others.

Indirect Fired Gas Heat

For complete product information refer to catalog Model IG or Model IGX, or contact your local representative.
88
maKe-Up aiR

IG Dimensional Data
B A
10 ft. min A max

36 in.

B max

Stand-alone - arrangement dB/HZ


Housing Size H10 H20 H30 arr. dB/HZ a 90 93 102 B 26 26 26 Width 44 53 53

Combination package - arrangement dBC


Housing Size H10 H20 H30 arr. dBC a 182 183 181 B 56 56 56 Width 48 53 53

Dimensions are in inches and include mixing box and standard weatherhood. For roof opening dimensions and locations refer to factory submittal.

Dimensions are in inches.

Consult your representative for dimensional data when the evaporative cooling option is selected. For roof opening locations refer to factory submittal/IOM.

IGX Dimensional Data

10 ft. min.

Stand-alone - arrangement dB/HZ


Housing Size H12 H22 H32 arr. dB/HZ a 122 140* 173* B 40 46 49 Width 33+ 44 52

Combination package - arrangement dBC


Housing Size H12 H22 H32 arr. dBC a 166 206* 242* B 46 54 62 Width 33+ 44 52

All dimensions are in inches. * A dimension for units with only one furnace. Add 33 in. for each additional furnace. + Furnace section width is 44 in. for 200 MBH and 250 MBH furnace sizes.

Indirect Fired Gas Heat

Consult your representative for dimensional data when the evaporative cooling option is selected. For roof opening locations refer to factory submittal/IOM.

maKe-Up aiR

89

Untempered Make-Up Air Systems - KSFD/KSFB


The Greenheck models KSFD and KSFB are designed to provide untempered make-up air for commercial and institutional kitchens. Installation may be stand-alone or on a combination curb with model CUBE exhaust fan.

SErvicE in chart StocK


KSFD KSFB 3

3 daY
3 3

5 daY
3 3

10 daY
3 3

PErFOrMANCE STANDArD CONSTrUCTION FEATUrES


Durable construction Weatherhood Vibration isolators Hinged access panels Factory wired and tested Intake filters A variety of blowers provide airflow capacities as high as 10,500 cfm with static pressures up to 2 in. wg.

STOCK UNITS Model KSFD-70-H05-01-QD HP 1/4 3/4 1/2 Voltage 115 115 115 Phase 1 1 2

KSFD-80-H05-01-QD KSFD-90-H05-01-QD

STANDArD ArrANGEMENTS
Models KSFD and KSFB have a compact design available with a horizontal discharge (arrangement HZ) or a downblast discharge (arrangement DB). Installation may be as a stand-alone supply fan or a combination package with exhaust and supply fan on a common curb.

Stock model is constructed of galvanized steel. Features include weatherhood with aluminum mesh filters and are ETL label.

OPTIONS AND ACCESSOrIES


KSFD KSFB
n n n n n n n

OPTIONS AND ACCESSOrIES Control Panel (rSCP shipped loose) roof Curb Combo Curb Duct Adapter Dampers Speed Controller Ext. Weatherhood UL/cUL 705 Horizontal Discharge Downblast Discharge

OPTIONAL rEMOTE PANEL


Prewired in compliance to the National Electric Code, the KFCC simplifies field wiring, thereby Code, reducing installation time and mistakes. The control center is a UL Listed NEMA-1 panel for mounting indoors and is designed to interlock with the fire suppression system. The KFCC is available on the KSFD and KSFB.

n n n n n n n n

n n n n

COMBINATION PACKAGES
The Greenheck combination package simplifies installation and reduces field labor costs. The pre-engineered design ensures that the supply fan, exhaust fan, curb and combination extension components interface properly. Equally important, Greenheck combination packages are specifically designed to comply with NFPA 96.

rEMOTE STArTEr CONTrOL PANEL (rSCP)


The remote Starter Control Panel (rSCP) offers safety and reliability for remote operation of up to four fans. Standard NEMA-3R housing allows panel to be mounted outdoors. Multiple supply voltages Wide range of horsepowers Disconnect switch(es) Control transformer for low voltage remote switching Terminal strips Fuse blocks Electronic motor overload protection For complete product information refer to catalog Models KSFB and KSFD, or contact your local representative.

90

maKe-Up aiR

Make-Up Air Systems - KSFD/KSFB


A
A kSFd and kSFB - arr. dB
Housing Size H05 H08 a 40.8 40.8 80.3 99.3 B 14.5 14.5 22.3 29.5 Width 19.8 36.8 31.8 40.0

H15 H25

kSFd and kSFB - arr. HZ DB


Housing Size a 31.5 31.5 71.0 81.3 B 18.5 18.5 25.3 34.0 Width 19.8 36.8 31.8 40.0

Hz.

H05 H08 H15 H25

Stand-alOne - Standard WeatHerHOOd

All dimensions are in inches.

A
kSFd and kSFB - arr. dB
Housing Size H05 H08 H15 a 130.0 124.8 145.3 152.5 B 18.5 18.5 25.3 34.0 Width 19.8 36.8 31.8 40.0

Stand-alOne - eXtended WeatHerHOOd

H25

All dimensions are in inches.

A
Dimensions are in inches and include mixing box and standard weatherhood. For roof opening dimensions and locations refer to factory submittal.

kSFd and kSFB - arr. dB3


Housing Size H05 H08 H15 H25 a* 70.0 82.3 131.5 159.8 B* 45.0 46.5 48.8 51.5 Width* 25.0 36.8 42.8 50.0

3 ft. min.

All dimensions are in inches. *Maximum dimensions (dependent on CUBE fan).

3 Ft. VertiCal SeparatiOn COMBinatiOn paCkage - Standard WeatHerHOOd

kSFd and kSFB - arr. dBC


Housing Size a* 159.3 166.3 196.5 212.8 B* 45.0 46.5 48.8 51.5 Width* 25.0 36.8 42.8 50.0

10 ft. min.

H05 H08 H15 H25

10 Ft. HOriZOntal SeparatiOn COMBinatiOn paCkage eXtended WeatHerHOOd

Consult your representative for dimensional data when the evaporative cooling option is selected.

All dimensions are in inches. *Maximum dimensions (dependent on CUBE fan).

maKe-Up aiR

91

Indoor Air Handlers


Vertical Fan Coil - VFC
Belt drive model VFC provides a low-cost method of air conditioning and/or heating for applications requiring a small footprint. These units utilize a steel double-wall cabinet construction with hinged motor access.

PErFOrMANCE
Performance capabilities range from 300 to 4,000 cfm and up to 3.3 in. wg

SErvicE chart
VFC w/out coil

10 15 daY daY
3 3 3 3

STANDArD CONSTrUCTION Coil rows 2, 4 and 6 3* FEATUrES


Coil rows 1 and 8

Double-wall construction Hinged/removable side access panels *Only hot water and chilled water coils with Internal isolation half inch circuiting, 10 FPI and B fin type Stainless steel drain pan

OPTIONS AND ACCESSOrIES the lead time out to a 15-day.


Internal spring isolation Coils - hot water, chilled water, direct expansion and steam Prefilters - vertical, 2- or 4-inch, pleated or aluminum, 30 or 65% efficiencies

qualify for a 10-day. Any variation will force

Increased rigidity Formed Access Panels

Excellent IAQ Double-Wall Construction

Less noise, Less Vibration Quality Ensures Longevity Stainless Steel Drain Pan Internal Spring Isolation

VFC DIMENSIONAL DATA


Unit Size
600 800 1300 1600 2000 2400 3000

Height
40 40 44 44 52 52 52

Width
24 24 24 30 34 34 50

Depth
24 24 28 28 28 28 32

Inlet Width
18 18 18 22 29 29 45

Height
22 22 22 22 23 23 22

Width
6.75 6.75 8.50 9 10 10 12.75

Outlet Height
4 6.50 8 9 9 10.25 12

All dimensions are shown in inches.

VFC PErFOrMANCE DATA


UNIT SIZE (NOMINAL CFM) FAN/MOTOr DATA rPM range HP range Max. BHP CFM range FILTEr DATA Qty. & Size - in. (cm) Area - ft2 Velocity - ft/min. COIL DATA Area - ft2 Width - in. Length - in. Velocity- ft/min. 600 1100 - 3500 .25 - 2 2.1 300 - 800 1 - 20 x 24 2.7 222 2.7 22.5 17 222 800 1100 - 3500 .25 - 2 2.1 500 - 1300 1 - 20 x 24 2.7 296 2.7 22.5 17 296 1300 800 - 2350 .25 - 2 2.1 800 - 1600 1 - 20 x 24 2.7 481 2.7 22.5 17 481 1600 750 - 2000 .25 - 2 2.1 1300 - 2000 1 - 24 x 24 3.6 444 3.6 22.5 23 444 2000 725 - 2150 .25 - 3 3.15 1300 - 2600 2 - 16 x 25 4.7 426 4.7 24 27 426 2400 650 - 1900 .25 - 3 3.15 1300 - 3200 2 - 16 x 25 4.7 511 4.7 24 27 511 3000 500 - 1650 .25 - 3 3.15 1300 - 4000 2 - 24 x 24 6.7 448 6.7 22.5 43 448

For complete performance information see CAPS.

For more product information refer to catalog Indoor Air Handling Units, or contact your local representative.

92

indooR aiR handleRS

Vertical Fan Coil - VFCD


Direct drive model VFCD provides a low-cost method of air conditioning and/or heating for applications requiring a small footprint. These units utilize a steel double-wall cabinet construction with hinged motor access.

PErFOrMANCE
Performance capabilities range from 300 to 4,000 cfm and up to 1.5 in. wg

SErvicE chart
VFCD w/out coil Coil rows 2, 4 and 6 Coil rows 1 and 8

10 15 daY daY
3 3* 3 3 3

STANDArD CONSTrUCTION FEATUrES


Double-wall construction Hinged/removable side access panels Easy slide out motor and scroll Stainless steel drain pan

*Only hot water and chilled water coils

OPTIONS AND ACCESSOrIES

with half inch circuiting, 10 FPI and B fin type qualify for a 10-day. Any variation will force the lead time out to a 15-day.

Coils - hot water, chilled water, direct expansion and steam Prefilters - vertical, 2- or 4-inch, pleated or aluminum, 30 or 65% efficiencies

Increased rigidity Formed Access Panels


Unit Size
600 800 1300 1600 2000 2400 3000

Excellent IAQ Double-Wall Construction

Quality Ensures Longevity Stainless Steel Drain Pan

Easy Slide Out Motor and Scroll

Outlet Vetrtical Air Flow Option

VFCD DIMENSIONAL DATA


Height
40 40 44 44 52 52 52

Width
24 24 24 30 34 34 50

Depth
24 24 28 28 28 28 32

Inlet Width
18 18 18 22 29 29 45

Height
22 22 22 22 23 23 22

Width
5.5 7.25 18 18 26 26 32.88

Outlet Height
5.50 5.50 5.63 5.63 5.63 5.63 10.38
Inlet Air Flow B

Filter Projection 2 or 4 in.

D E

All dimensions are shown in inches.

VFCD PErFOrMANCE DATA


UNIT SIZE (NOMINAL CFM) FAN/MOTOr DATA rPM range HP range Max. BHP CFM range FILTEr DATA Qty. & Size - in. (cm) Area - ft2 Velocity - ft/min. COIL DATA Area - ft2 Width - in. Length - in. Velocity- ft/min. 2.7 22.5 17 222 2.7 22.5 17 296 2.7 22.5 17 481 3.6 22.5 23 444 4.7 25 27 426 4.7 25 27 511 1 - 20 x 24 2.7 222 1 - 20 x 24 2.7 296 1 - 20 x 24 2.7 481 1 - 24 x 24 3.6 444 2 - 16 x 25 4.7 426 2 - 16 x 25 4.7 511 960-1600 .25 - 2 3.8 250-770 900-1500 .25 - 2 3.8 250-950 870 - 1450 .25 - 2 7.8 700-1640 966 - 1610 .25 - 2 9 900-1640 660 - 1100 .25 - 3 7.8 900-2400 870 - 1450 .25 - 3 5.6 1300-3000 600 800 1300 1600 2000 2400

3000

660 - 1100 .25 - 3 7.1 1300-4000

2 - 24 x 24 6.7 448

6.7 22.5 43 448

For complete performance information see CAPS.

For more product information refer to catalog Indoor Air Handling Units, or contact your local representative.
indooR aiR handleRS

93

Horizontal Fan Coil - HFCB


Greenhecks indoor air handling series, model HFCB, provides air conditioning and/or heating for buildings and specific spaces. These competitively priced units are designed with a wide range of construction features allowing it to be used in a number of applications such as schools, office buildings, apartments, medical facilities, and many other commercial applications. Modular construction allows the engineer to configure the unit to meet their exact requirements. The modular construction also make this unit ideal for retrofit applications. Each model has a variety of options, accessories, and a wide performance range with quiet, trouble-free operation.

SErvicE chart
HFC w/out coil Coil rows 2, 4 and 6

10 daY
3 3

PErFOrMANCE
Performance capabilities range from 330 to 5,000 cfm and up to 3.3 in. wg.

STANDArD CONSTrUCTION FEATUrES


Double-wall construction Removable side access panels Internal isolation Stainless steel drain pan
AIRFLOW

OPTIONS AND ACCESSOrIES


Coils - hot water, chilled water, and direct expansion Prefilters - vertical, 2-inch pleated, 30% efficiencies

HFC FILTEr CHArT


FILTEr CHArT

Vertical
D

Size 008

Filter Size (in.) 16 x 25 20 x 25 16 x 20 20 x 20 16 x 20 16 x 25

Qty. 1 1 2 2 4 4

Face Area (ft) 2.8 3.5 4.4 5.6 8.9 11.1

012 016 020 030 040

HFCB/D
HFCB DIMENSIONAL DATA
MODULE SIZING

Dimensions shown in inches.

Size 008 012 016 020 030 040

Mixing Coil w/ Blower Height Width Inlet Outlet Filter Nominal Box Flange CFM Unit A B C D Height Width Height Width Width 800 1200 1600 2000 3000 4000 22.0 22.0 22.0 26.0 28.0 28.0 23.5 23.5 23.5 23.5 23.5 23.5 29.0 29.0 29.0 29.0 29.0 32.0 17.75 21.75 21.75 21.75 33.25 33.25 26.5 26.5 33.0 41.0 41.0 51.0 13.5 17.5 17.5 17.5 29.0 29.0 22.25 22.25 28.75 36.75 36.75 46.75 10.52 10.52 11.88 11.88 11.88 14 7.31 7.31 8.75 8.75 13.63 11.25 1.50 1.50 1.50 1.50 1.50 1.50

OUTLET ArEA Model HFCB 008 0.30 012 0.30 016 0.36 020 0.36 030 1.00 040 1.00

Dimensions shown in ft 2

Dimensions shown in inches.

For more product information refer to catalog Model HFC, or contact your local representative.
94
indooR aiR handleRS

Horizontal Fan Coil - HFCD


Direct drive model HFCD, provides air conditioning and/or heating for buildings and specific spaces. These competitively priced units are designed with a wide range of construction features allowing it to be used in a number of applications such as schools, office buildings, apartments, medical facilities, and many other commercial applications. Modular construction allows the engineer to configure the unit to meet their exact requirements. The modular construction also make this unit ideal for retrofit applications. Each model has a variety of options, accessories, and a wide performance range with quiet, trouble-free operation.

SErvicE chart
HFC w/out coil Coil rows 2, 4 and 6

10 daY
3 3

PErFOrMANCE
Performance capabilities range from 450 to 2,475 cfm and up to 1.8 in. wg.

STANDArD CONSTrUCTION FEATUrES


Double-wall construction Removable side access panels Internal isolation Stainless steel drain pan
AIRFLOW

OPTIONS AND ACCESSOrIES


Coils - hot water, chilled water, and direct expansion Prefilters - vertical, 2-inch pleated, 30% efficiencies

HFC FILTEr CHArT


FILTEr CHArT

Vertical
D

Size 008

Filter Size (in.) 16 x 25 20 x 25 16 x 20 20 x 20 16 x 20 16 x 25

Qty. 1 1 2 2 4 4

Face Area (ft) 2.8 3.5 4.4 5.6 8.9 11.1

012 016 020 030 040

HFCB/D
HFCD DIMENSIONAL DATA
MODULE SIZING

Dimensions shown in inches.

Size 008 012 016 020

Mixing Coil w/ Blower Height Width Inlet Outlet Filter Nominal Box Flange CFM Unit A B C D Height Width Height Width Width 800 1200 1600 2000 22.0 22.0 22.0 26.0 23.5 23.5 23.5 23.5 29.0 29.0 29.0 29.0 17.75 21.75 21.75 21.75 26.5 26.5 33.0 41.0 13.5 17.5 17.5 17.5 22.25 22.25 22.25 36.75 5.88 5.75 5.75 5.88 7.75 18.0 18.0 26.38 1.50 1.50 1.50 1.50

OUTLET ArEA Model HFCD 008 0.28 012 0.70 016 0.70 020 1.02 030 040

Dimensions shown in inches.

Dimensions shown in ft 2

For more product information refer to catalog Model HFC, or contact your local representative.
indooR aiR handleRS

95

Low-Profile Fan Coil - LFC


Model LFC provides a low-cost method of air conditioning and/or heating a building or specific space. These units come standard with a low-profile, double-wall constructed cabinet designed to fit in tight ceiling spaces. They utilize two types of forward-curved wheels providing a wide performance range and quiet operation.

PErFOrMANCE
Performance capabilities range from 360 to 5,300 cfm and up to 4 in. wg.

SErvicE chart
LFC Coil rows 2, 4 and 6 Coil rows 1 and 8

10 daY
3 3*

15 daY
3 3 3

*Only hot water and chilled water coils with half inch

circuiting, 10 FPI and B fin type qualify for a 10-day. Any variation will force the lead time out to a 15-day.

STANDArD CONSTrUCTION MODULE SELECTION FEATUrES


Low-profile - as short as 11 inches Double-wall construction Two access panels per module Internal isolation Stainless steel drain pan

OPTIONS AND ACCESSOrIES

Heating coils (hot water and steam) Internal spring isolation Cooling coils (chilled water and DX) Coils - hot water, chilled water, direct Reheat coils expansion and steam Prefilter Prefilter - vertical or sloped, 2- or Mixing box 4-inch, pleated or aluminum, 30, 65 or 95% efficiencies Mixing box - w/ or w/o dampers, w/ or w/o filters, inlet configuration any two of top, end, bottom, right or left

Quality Ensures Longevity Stainless Steel Drain Pan

Increased rigidity Formed Access Panels

Quick Easy Maintenance Filter Access

Excellent IAQ Double-Wall Construction

Less Noise, Less Vibration Internal Spring Isolation

Mix Air Evenly MixingBox Module

LFC DIMENSIONAL DATA


Unit Size
15 20 25 30 45 50 65 85

w/o Filter
40 40 40 45 45 48 52 52

A w/ 2 in. w/ 4 in. Filter Filter


42 42 42 47 47 50 54 54 44 44 44 49 49 52 56 56

B
11 14 16 18.5 18.5 21 26 26

Width
38 38 38 38 50 50 50 62

Inlet
9.0 12 14 16.5 16.5 19 24 24 36 36 36 36 48 48 48 60

Outlet Width
6.75 6.75 8.50 9.0 10 10 12.75 15 4.0 6.50 8.0 9.0 9.0 10.25 12 12

Height Width Height

All dimensions are shown in inches.

For more product information refer to catalog Indoor Air Handling Units, or contact your local representative.

96

indooR aiR handleRS

Modular Small Cabinet Fan - MSCF


Model MSCF provides a low-cost method of air conditioning and/or heating a building or specific space. These units come standard with a low-profile, double-wall constructed cabinet designed to fit in tight ceiling spaces. They utilize two types of forward-curved wheels providing a wide performance range and quiet operation. The MSCF is also available with a backward-inclined (BI) wheel.

PErFOrMANCE

Performance capabilities range from 360 to 5,300 cfm and up to 4.5 in. wg.

SErvicE chart
MSCF Coil rows 2, 4 and 6 Coil rows 1 and 8

10 daY
3 3*

15 daY
3 3 3

*Only hot water and chilled water coils with half inch

STANDArD CONSTrUCTION MODULE SELECTION FEATUrES


circuiting, 10 FPI and B fin type qualify for a 10-day. Any variation will force the lead time out to a 15-day.

OPTIONS AND ACCESSOrIES

ING BOX AMPER

Heating coils (hot water and steam) Internal spring isolation Modular construction Low-profile - as short as 11 inches Cooling coils (chilled water and DX) Coils - hot water, chilled water, direct expansion and steam Reheat coils Double-wall construction Prefilter and/or postfilters CHILLED Prefilter - vertical or sloped, 2 or 4 Two access panels per module CHILLED Mixing box Internal isolation 24 WATER WATER 12 HEATINGVERTICAL 12 24 HEATINGinch, pleated or aluminum, 30, 65 or VERTICAL MIXING BOX FAN FAN PLENUM PLENUM Stainless steel drain pan COIL COIL PLENUM COIL FILTER PLENUM FILTERPre and/or post access plenums COIL 95% efficiencies w/DAMPER Mixing box - w/ or w/o dampers, w/ or w/o filters, inlet configuration any two of top, end, bottom, right or left

Easy Installation Modular Construction

Quality Ensures Longevity Stainless Steel Drain Pan

Increased rigidity Formed Access Panels

Quick Easy Maintenance Filter Module

Excellent IAQ Double-Wall Construction

Less Noise, Less Vibration Internal Spring Isolation

Mix Air Evenly MixingBox Module

Mixing Box

Plenum

Filter

Heating

Cooling

Fan G

A
a w/o w/ Filter Filter 11 24.5 14 24.5 16 27 18.5 31 18.5 32 21 32 26 38 26 38

B
B 12 in. 12.75 12.75 12.75 12.75 12.75 12.75 12.75 12.75 24 in. 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 C

D
d Hot Water 4 row HW 1 & 2 row & Steam 12.75 15.5 12.75 15.5 12.75 15.5 12.75 15.5 12.75 15.5 12.75 15.5 12.75 15.5 12.75 15.5

E
inlet e 24.5 24.5 24.5 24.5 24.5 24.5 24.5 24.5 F 25 25 29 32 32 38 42 42 g 11 14 16 18.5 18.5 21 26 26 unit 38 38 38 38 50 50 50 62

F
Outlet

MSCF DIMENSIONAL DATA


unit Size 15 20 25 30 45 50 65 85 Vertical Sloped 12.75 12.75 12.75 12.75 12.75 12.75 12.75 12.75 24.5 24.5 27 31 32 32 38 38 Height Width Height Width 9 12 14 16.5 16.5 19 24 24 36 36 36 36 48 48 48 60 4 6.75 6.50 6.75 8 8.50 9 9 9 10 10 10.25 12 12.75 12 15

For more product information refer to catalog Indoor Air Handling Units, or contact your local representative.
97

All dimensions are in inches. For complete dimensional information, see CAPS submittal drawings.
indooR aiR handleRS

LFC/MSCF Performance Data


unit SiZe nOMinal CFM FAN/MOTOr DATA rPM range HP range Max. BHP CFM range VErTICAL FILTEr DATA Qty. & Size - in. Area - ft2 Velocity - ft/min. ^ SLOPED FILTEr DATA Qty. & Size - in. Area - ft
2

15 800

20 1100

25 1350

30 1600

45 2250

50 2600

65 3350

85 4300

1100 - 3500 .25 - 2 2.1 300 - 800

1100 - 3500 .25 - 2 2.1 600 - 1100 1 - 12 x 12 1 - 12 x 24 2.5 440 1 - 16 x 16 1 - 16 x 20 3.4 324

800 - 3050 .25 - 3 2.1 900 - 1800

750 - 2500 .25 - 3 3.15 1200 - 2400 1 - 16 x 16 1 - 16 x 20 3.4 471 1 - 12 x 24 1 - 24 x 24 5.3 302

725 - 2400 .25 - 3 3.15 1500 - 2900

650 - 2200 .25 - 5 5.25 1800 - 3600

500 - 2000 .25 - 7.5 7.875 2400 - 4200

500 - 2200 .25 - 10 10.5 3000 - 5800 1 - 12 x 24 2 - 24 x 24 8.9 483 2 - 12 x 24 4 - 24 x 24 17.8 242

2 - 9 x 18 1.8 444 1 - 12 x 12 1 - 12 x 24 2.5 320

2 - 14 x 18 3.0 450

2 - 16 x 24 4.8 469

2 - 18 x 24 5.4 481

2 - 24 x 24 7.2 465

2 - 16 x 20 3.8 355

2 - 24 x 24 7.2 313

2 - 24x24 7.2 361

4 - 24x24 14.4 233

Velocity - ft/min. COIL DATA Area - ft2 Width - in. Length - in. Velocity- ft/min.

1.6 7.50 31.00 500

2.2 10.00 31.00 500

2.7 12.50 31.00 500

3.2 15.00 31.00 500

4.5 15.00 43.00 500

5.2 17.50 43.00 500

6.7 22.50 43.00 500

8.6 22.50 55.00 500

^ Available for MSCF unit only. For complete performance information see CAPS.

98

indooR aiR handleRS

Underfloor Fan Terminal - UFT


The Greenheck model UFT is designed for an underfloor air distribution system to provide cooling or heating to the perimeter zones or interior rooms. Performance ranges from 130 to 1798 cfm with static pressures to 0.875 inches wg. Underfloor systems offer reduced energy and equipment costs, simple installation, cleaner, healthier air, more design flexibility and individual occupant flow control.

SErvicE chart
UFT without Coil UFT with Hot Water 115, 230 & 277 Volt

10 daY
3 3 3

STANDArD CONSTrUCTION FEATUrES


Higher cfm per terminal Cost-effective installation Integral reheat Quiet operation Ease of maintenance

INSTALLATION - FAN PLACEMENT


raised floor systems are designed to allow for cables and equipment to be run under the floor. To accomplish this task, the floor is supported with pedestals that are placed 24 inches apart. The UFT is designed specifically for the raised floor application, allowing it to fit perfectly between these pedestals, while allowing an outlet duct to be attached if desired. raised floor heights range from 12 inches and above. Greenheck has designed the UFT in two heights, Series 10 and 13 to accommodate the various heights.

UFT STANDArD CONDENSED PErFOrMANCE rANGES & DIMENSIONAL DATA


MOdel uFt-10-1 uFt-13-1 uFt-10-2 uFt-13-2 CFM 600 851 1336 1742 unit HeigHt (in.) 10.38 13.13 10.38 13.13 FlOOr HeigHtS 12 14 16 18

raised floor support pedestals

24 in.

3 3

3 3 3 3

3 3 3 3

3 3 3 3

DoubleScroll UFT

Airflow

24 in.

For complete information refer to catalog Underfloor Fan Terminal - Model UFT, or contact your local representative.

Single-Scroll UFT

Airflow

ETL Listed for Fan Coil Unit and in accordance with UL/cUL 1995.
R

indooR aiR handleRS

99

Custom Coils
Custom Coils
Greenheck specializes in manufacturing competitively priced, qualityengineered replacement and OEM coils. Every coil we build is leak tested under water with 450 PSIG of dry nitrogen to guarantee 100% quality assurance. Greenhecks experienced team of application specialists are only a phone call away, ready to quickly respond to any questions you may have.

SErvicE chart
Custom Coils

3 daY
3

5 daY
3

10 daY
3

Our Quick Build (QB) program ensures that your coils will be manufactured to your specifications and shipped according to your needs.

To guarantee your coil is going to perform as required, check for AHrI Certification. Fin Material Connection Types FPT - Female pipe thread MPT - Male pipe thread Casing Types Std. (1.5-inch flange) Standard Booster (1-inch flange) Slip and drive Endplates only Inverted S. P. flange refrigerant Types r-22 R-134a r-404A r-407C r-410A r-502 Sweat Fluid Flow rates For water coils, connections sizes are based on GPM of water GPM 1-4 4-8 8-16 16-30 30-40 40-70 75-150 Conn. 3/4 1 1 1/4 1 1/2 2 2 1/2 3 Aluminum Tube Diameter 3/8 3 1/2 3 5/8 3 Fin Thickness 0.006 3 0.008 3 0.010 3 Fin Type Sine-wave 3 Corrugated 3 Flat 3 Copper

3 3

Coil Type (Style) Custom Booster Chilled Hot direct Standard Steam Hot Standard Condenser Water Water expansion Steam distributing Water Steam Tube Diameter (inches) 3/8 3 3 3 3 1/2 3 3 3 3 5/8 3 3 3 3 3 3 rows Min rows 1 1 1 1 1 1 Max rows 12 12 12 12 2 2 Fin Height (inches) Min Fin height is dependent on tube diameter Max (see Tube Diameter chart) Increments of Fin Length (inches) Minimum fin length is 1 inch Min Max fin length is 250 inches w/ center supports every 50 inches Max no restriction on fin length increments Increments of recommended Face Velocity (FPM) Min 400 500 400 600 500 500 Max 550 800 550 750 850 850 recommended Fluid Velocity (FPS - for water coils) Min 1.5 1.5 NA NA NA NA Max 4.0 4.0 NA NA NA NA recommended Pressure Drop (ft. of H2O or psi) Min 1 1 1.5 3 1 1 Max 20 10 9 10 125* 125* * Higher steam pressures will require heavier tube wall thicknesses. ** Booster coil fin lengths are dependent on fin height. 100
coilS

Casing Material Standard Optional 14 gauge 16 gauge galvanized steel galvanized steel 16 gauge stainless steel .06 or .09 in. thick copper Tube Diameter 3/8 1/2 5/8 Wall Thickness (inches) 0.016 3 3 0.020 3 3 0.025 3 0.035 3 0.049 3 Fin Type Aluminum 3 3 3 Copper 3 Fins Per Inch (FPI) Min 10 12 6 Max 20 16 14 Fin Type Sine-wave 3 3 Corrugated 3 Flat 3 Connection Size (inches) Min 0.5 0.5 0.5 Max 4.0 4.0 4.0 Fin Height (inches) Min 4.0 5.0 4.5 Max 60 120 120 Increments of 1.00 1.25 1.50

3 1 2 6 24 3 6 48** 1 500 800 1.5 4.0 1 10

3 1 2 6 24 3 6 48** 1 500 850 NA NA 1 125*

For more product information refer to Catalog Custom Coils, or contact your local representative.

Dampers
Curtain and Multi-Blade Fire Dampers
Greenheck fire dampers are qualified under UL/cUL 555 Standard for fire dampers. Fire dampers are required by all building codes to maintain the required fire resistance ratings of walls, partitions, and floors when they are penetrated by air ducts or other ventilation openings. Fire dampers close automatically upon detection of heat (usually by the melting of a fusible link at 165F) blocking the opening and preventing the spread of fire into the adjoining compartment or spaces.

StanDarD ConStrUCtion FeatUreS


Galvanized steel Fabricated to your size requirements UL/cUL 555 Classified Dynamic (DFD) and static (FD) rated models Horizontal and vertical mounts

oPtionS anD aCCeSSorieS

NeXt 3 5 10 DaY DaY DaY DaY 11/2 HoUr rateD CUrtain Fire DaMPer Standard Frame Model 150 3 3 3 3 type a, B, B2, r, Cr, C, Co Standard Frame (Sealed) Model 155 3 3 3 type Cr, C,Co, r (DFD-150 X 12) integral Sleeve Model 150XaV 8 x 8, 10 x 10, 3 3 3 3 type a, B, r, Cr, C, Co 12x12, 18 x 18, 24 x 24 narrowline Model 110 3 3 3 3 type a, B, B2 Ultra thin Model 100 3 3 type a, B Stainless Steel 150, 3 155(304SS) out of Wall oFD-150, 3 3 3 oDFD-150 11/2 HoUr rateD roUnD Fire DaMPer Service chart iN StOcK SizeS round FDr-510, DFDr-510, SSFDr-510, SSDFDr-510(304SS) SeDFDr-510 Severe environment (316SS) MULti-BLaDe Fire DaMPer DFD-210, 230 SeDFD-210 (316SS) DFDtF-210, DFDaF-310 3 3 3 3 HoUr rateD CUrtain Fire DaMPer Standard Frame Model 350 3 type a, B, B2, r, Cr, C, Co Standard Frame (Sealed) Model 355 - type Cr, C, Co narrowline Model 310 3 type a, B, B2 Ultra thin Model 300 type a, B, B2 Stainless Steel 350, 355
Greenheck Fan Corp. certifies that the models DFD-210, DFD-230, DFDtF-210, SeDFD-210, and SSDFD-210 shown herein are licensed to bear the aMCa Seal. the ratings shown are based on tests and procedures performed in accordance with aMCa Publication 511 and comply with the requirements of the aMCa Certified ratings Programs. the aMCa Certified ratings Seal applies to air performance ratings only.

P.o.C. - one piece retaining angles (loose or mounted) Flanged sleeves SSC option, ETL (curtain only) Duct access doors - hinged and cam-style (Stock sizes available: 6x6, 8x8, 10x10, 12x12, 14x14, 16x16, 18x18, 20x20, 24x24 - Stocked in WI, CA, and KY) Sleeves - (20 Ga.): 10, 12, 14, 16, 21, 24 inches (16 Ga.): 10, 12, 14, 16, 21, 24 inches (14 Ga.): 10, 12, 14, 16, 21, 24 inches Fusible link temperature options - 165F, 212F & 286F 316 stainless steel - severe environment dampers Breakaway Sealed transition/sleeve Factory mounted access door

tranSition tyPeS - CUrtain

Blades In Airstream Blades In Airstream

Type A Type A

Blades Out Of Blades Out Of Airstream Airstream

Type B* Type B*

100% Free Area 100% Free Area

Type C* Type C*

Steel Stud Frame


Type CO* Type CO* Type CR* Type CR* Type R* Type R*

3 3 3

100% Free Area 100% Free Area

100% Free Area 100% Free Area

High Free Area High Free Area

* For Blade Stack Dimensions, refer to specification sheets on www.greenheck.com

PoC UnMoUnteD
A A-

3 3 3
Steel Stud Wall

3 3 3

3 3 3 3

3 3 3 3 3

SSC oPtionS
Steel Stud Frame Wallboar d

Retaining Bar

Damper Sleeve

Cross-Section A-A
DAMPERS

101

Smoke Dampers
Greenhecks smoke dampers are qualified under UL/cUL 555S, Standard for smoke dampers. Smoke dampers prevent the circulation of air and smoke through a duct or a ventilation opening in a smoke separation.

PerForManCe
Performance capabilities up to 3000 fpm and 6 in. wg of static pressure.

StanDarD ConStrUCtion FeatUreS


Galvanized steel and aluminum Fabricated to your size requirements UL/cUL 555S Classified Factory mounted actuators (120 vac, 24 vac, 230 vac, and Pneumatic) three blade styles

oPtionS anD aCCeSSorieS


oCi - open/Closed indicator transitions - oval, round and rectangular Factory sleeves (20 Ga.): 16, 21, 24 inches (16 Ga.): 16, 21, 24 inches (14 Ga.): 16, 21, 24 inches Stainless steel bearings eP switch, transformers, momentary switch P.O.C. one piece retaining angle (loose or mounted) Smoke detector Momentary switch 316 stainless steel severe environment dampers GTS-3 & GTS-4 Security bars Breakaway Quick connections S & Drive connection Factory mounted access door

Service chart
3V BLaDe StyLe (aMCa Licensed air Performance) (recommended for velocities up to 2000 fpm and 4 in. wg) SMD-201, 202, 203 - leakage class i, ii, iii airFoiL BLaDe StyLe (recommended for velocities up to 3000 fpm and 6 in. wg) SMD-301, 302, SMD-301M, 302M, SMD-301V - galvanized, leakage class i, ii SMD-401, SMD-401M - aluminum, leakage class i roUnD BLaDe StyLe (recommended for velocities up to 2000 fpm and 4 in. wg) SMDr-501, 502 StainLeSS SteeL MoDeLS (recommended for velocities up to 2000 fpm and 4 in. wg) SSSMDr-501, 502 (304SS) stainless steel round SeSMD-201 (316SS) SeSMDr-501 (316SS) SSSMD-201 (304SS)

NeXt DaY
3

3 DaY
3

5 DaY
3

10 DaY
triPLe Vee
3

3 3

3 3

3 3

3 3

airFoiL

3 3 3 3 3 3
100% Free Area

roUnD

Blades In Airstream tranSitionBlades Out Of tyPeS Airstream

Type A

Type B*

Type C*

100% Free Area

typeCO* Type o

100% Free Area

typeCR* Type r

High Free Area

Type R*

Greenheck Fan Corporation certifies that the models SMD-201, 202, 203, 301, 302, 301M, 302M; SeSMD-201 and SSSMD-201 shown herein are licensed to bear the aMCa Seal. the ratings shown are based on tests and procedures performed in accordance with aMCa Publication 511 and comply with the requirements of the aMCa Certified ratings Programs. the aMCa Certified ratings Seal applies to air performance only.

the oCi control option is an SPDt switch typically used to indicate whether the smoke damper blades are open or closed.

oCi

Blades In Airstream

Type A

102

DAMPERS

Blades Out Of Airstream

Type B*

100% Free Area

type C Type C*

Fire Smoke Dampers

MoDeL FSD: traditional Fire Smoke

Classified to UL/cUL 555 and UL/cUL 555S and must be mounted within the plane of the wall or floor. rated for airflow and leakage in either direction.

Performance

Performance capabilities up to 3000 fpm and 4 in. wg of staticpressure.

Classified to UL/cUL 555 and UL/cUL 555S and can be installed outside of the plane of the wall or floor. this allows the actuator to be mounted internally with convenient access to the damper, actuator, and heat responsive device through the grille. the entire installation can be done from the grille side of the opening. rated for airflow and leakage in either direction.

MoDeL oFSD: out of Wall Fire Smoke

Performance

Performance capabilities up to 3000 fpm and 4 in. wg of staticpressure.

MoDeL CFSD: Corridor Fire Smoke

Models each with three mounting configurations available. 1-hour Corridor Fire resistance rating and UL/cUL 555S Leakage Rating. Can be installed horizontally behind grilles and diffusers in corridor penetrations with ratings for airflow and leakage in either direction.

Performance

Performance capabilities up to 2000 fpm and 4 in. wg of staticpressure.

tranSition tyPeS

airFoiL

rrL - Standard (Standard on QD Stock Models)

Thermostat

3V
100% Free Area

Type O

100% Free Area

Type R

100% Free Area

Type C

Greenheck Fan Corporation certifies that the models CFSD-211, 212; FSD-211, 212, 213, 231, 311, 311M, 312, 312M; SSFSD-211; SeFSD-211; oFSD-211, 212, 311, and 312 shown herein are licensed to bear the aMCa Seal. the ratings shown are based on tests and procedures performed in accordance with aMCa Publication 511 and comply with the requirements of the aMCa Certified ratings Programs. the aMCa Certified ratings Seal applies to air performance only.

tor

High Temp. Sensor Primary Sensor

oCi

DAMPERS

103

Fire Smoke Dampers


Service chart
Fire SMoKe 3V BLaDe StyLe (aMCa Licensed air Performance) (Maximum ratings up to 2000 fpm and 4 in. wg) FSD-211, 212, 213 - 11/2 hour rated, leakage class i, ii, iii FSD-231 - 3 hour rated, leakage class i FSDr-511, 512 - 11/2 hour rated round airFoiL BLaDe StyLe (Maximum ratings up to 3000 fpm and 4 in. wg) FSD-311, FSD-311M, FSD-312, FSD-312M - 11/2 hour rated, leakage class i, ii FSD-311V - 11/2 hour rated, leakage class i, vert. blade FSD-331 - 3 hour rated, leakage class i, vert. blade CorriDor Fire/SMoKe 3V BLaDe StyLe (aMCa Licensed air Performance) (Maximum ratings up to 2000 fpm and 4 in. wg) CFSD-211 - 1 hour rated, leakage class i CFSD-212 - 1 hour rated, leakage class ii oUt-oF-WaLL Fire/SMoKe 3V Vee BLaDe StyLe (aMCa Licensed air Performance) (Maximum ratings up to 2000 fpm and 4 in. wg) oFSD-211, 212 - 11/2 hour rated, leakage class i, ii airFoiL BLaDe StyLe (Maximum ratings up to 3500 fpm and 8 in. wg) oFSD-311, 312 - 11/2 hour rated, leakage class i, ii StainLeSS SteeL MoDeLS SSFSD-211 (304SS) SeFSDr-511 (316SS), SSFSDr-511 (304SS) SeFSD-211 (316SS) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3
FSD-212 (rrL only) Sizes 8 x 8, 10 x 10, 12 x 12, 16 x 16, 20 x 20, 24 x 24

iN StOcK

NeXt 3 5 10 DaY DaY DaY DaY

3 3 3

3 3 3

3 3 3

3 3 3

StanDarD ConStrUCtion FeatUreS


FSD 3 3 3 OFSD 3 3 3 3 3 3 3 CFSD StanDarD COnStruCtiOn FeatureS 3 3 3 3 Galvanized Steel UL/cUL555 Classified/ UL/cUL555S Classified Factory Mounted actuators (120 vac, 24 vac and Pneumatic) Corridor rated Galvanized Sleeve - wrapped with thermal blanket rrL - resettable Link

oPtionS anD aCCeSSorieS


P.O.C. - One piece retaining angle RRL/OCI TOR - Temperature Override Transitions - oval, round andrectangular Factory sleeves (20 Ga.): 16, 21, 24 inches (16 Ga.): 16, 21, 24 inches (14 Ga.): 16, 21, 24 inches Stainless steel bushings
104
DAMPERS

EP switch Transformers Factory flanges Smoke detector (FSD only) Momentary switch PRV - Pneumatic Relief Value Greenheck Test Switch - GTS - 1, 2,3,4 Breakaway flanges Sealed transition sleeve Factory mounted access door

access Doors
access doors are designed for use in low to medium pressure duct systems. they provide a durable, practical, and inexpensive means of gaining access to damper components inside the ductwork.

StanDarD ConStrUCtion FeatUreS


Galvanized steel Cam style (CAD) Hinged style (HAD) Round style (RAD)

Service chart
CaD (Wi, Ca, FL & tX) HaD (Wi, Ca, FL & tX)

iN StOcK SizeS*
6x6, 8x8, 10x10, 12x12, 14x14, 16x16, 18x18, 20x20, 24x24 6x6, 8x8, 10x10, 12x12, 14x14, 16x16, 18x18, 20x20, 24x24

10 DaY
3

raD insulated or Uninsulated 6x6, 8x8, 10x10, (Wi, FL & tX) 12x12, 14x14, 16x16

Marine Dampers
Marine dampers are United States Coast Guard Class a-60 division and aBS approved. the marine dampers were tested at Underwriters Laboratories (UL) in accordance with International Maritime Organizations (IMO) Fire Test Procedure code. Fire and combination fire/smoke dampers can be used in marine and offshore ventilation systems.

StanDarD ConStrUCtion FeatUreS


Galvanized steel (IMO-310, IMO-311) 304 Stainless Steel (SSIMO-310, SSIMO-311) Airfoil blade design

Service chart
SSiMo-310 iMo-310 iMo-311 SSiMo-311

3 DaY
3 3

5 DaY
3 3

10 DaY
3 3 3 3

Greenheck Fan Corporation certifies that the models iMo-311 and SSiMo-311 shown herein is licensed to bear the aMCa Seal. the ratings shown are based on tests and procedures performed in accordance with aMCa Publication 511 and comply with the requirements of the aMCa Certified ratings Programs. the aMCa Certified ratings Seal applies to air performance ratings only.

DAMPERS

105

Ceiling radiation Dampers


Greenhecks ceiling radiation dampers are qualified under UL/cUL 555C, Standard for ceiling dampers. Ceiling radiation dampers are designed to function as a heat barrier in duct outlets penetrating fire resistive membrane ceilings. these dampers may be used in lieu of hinged door type dampers, in ceiling designs listed in the UL/cUL Fire resistance Directory which allow penetrations.

StanDarD ConStrUCtion FeatUreS

Galvanized steel UL/cUL 555C Listed Fabricated to your size requirements rectangular, round or curtaintype

oPtionS anD aCCeSSorieS


thermal blankets (1 in. mineral wool or quilted ceramic) - 24 in. x 24 in. adjustable volume controller (not available on stock units) top and bottom extension (5 & 10 day only)

Service chart
rectangular Frame (CrD-1)

StOcK SizeS*
6x6, 8x8, 9x9, 10x10, 12x12, 14x14, 22x10, 22x22 6, 8, 10, 12, 16 not applicable not applicable not applicable

3 DaY
3 3 3

5 DaY
3 3 3 3 3

10 DaY
3 3 3 3 3 3
CUrtain CrD-60

round Frame (CrD-2) Curtain Frame (CrD-60) Curtain Frame (CrD-60B) Curtain Frame (CrD-60X)

rectangular Frame, Low-profile (CrD-1LP)


* Stocked in WI & CA.

eXaMPLe oF tHerMaL BLanKet aPPLiCation Ceiling Radiation Damper Thermal Blanket


3 3/4" Max.

Lay-In Diffuser

Tee Bar roUnD CrD-2

CrD-60X

CrD-60B

reCtanGULar CrD-1

106

DAMPERS

Volume Control Dampers


Greenhecks control dampers are designed to control pressure, temperature or flow in an HVaC system. these dampers are available in parallel or opposed blade operation and can be supplied in both standard and low leakage construction. a control damper regulates pressure, temperature or flow by means of modulating or two position control. these dampers require operation by either manual, electric, or pneumatic actuators.

PerForManCe

Performance capabilities up to 6000 fpm, and 8 in. wg of static pressure.


Greenheck Fan Corporation certifies that the VCD-15, 18, 20, 23 and SeVCD-23 models shown herein are licensed to bear the aMCa Seal. the ratings shown are based on tests and procedures performed in accordance with aMCa Publication 511 and comply with the requirements of the aMCa Certified ratings Programs. the aMCa Certified ratings Seal applies to air performance ratings only.

StanDarD ConStrUCtion FeatUreS

Galvanized steel and aluminum Fabricated to your size requirements three blade styles

oPtionS anD aCCeSSorieS


transformers Factory mounted actuators - manual, electric and pneumatic Flanged frame (3, 5, and 10-day) Bronze or stainless steel bearings Stainless steel axles and linkages except VCD-15, VCD-18, VCDr-50/53 transitions - oval, round and rectangular P.O.C. one piece retaining angle Factory Sleeves (20 Ga.): 16, 21, 24 inches (16 Ga.): 16, 21 inches (14 Ga.): 16, 21 inches Severe environment dampers (316SS)

airFoiL

3V

roUnD

Service chart
3V BLaDe StyLe (aMCa Licensed air Performance) (recommended for velocities up to 1500 fpm and 2 in. wg) VCD-15, 18 - non low leakage and low leakage 3V BLaDe StyLe (aMCa Licensed air Performance) (recommended for velocities up to 2000 fpm and 2.5 in. wg) VCD-20 - non low leakage/VCD-20V (vertical) VCD-23 - low leakage/VCD-23V (vertical) GaLVaniZeD airFoiL BLaDe StyLe (recommended for velocities up to 4000 fpm and 8 in. wg) VCD-33, 34 - low leakage eXtrUDeD aLUMinUM airFoiL BLaDe StyLe (recommended for velocities up to 6000 fpm and 6 in. wg) VCD-42, 43 - low leakage VCD-40 - ultra low leakage roUnD BLaDe StyLe (recommended for velocities up to 2000 fpm and 2.5 in. wg) VCDr-50, 53 - non low leakage and low leakage VCDrM-50, 53 - non low leakage and low leakage SeVere enVironMent DaMPerS (316SS) SeVCD-23 SeVCD-33 VCD-20V, 23V, 33V, 42V, 43V

iN StOcK

NeXt DaY

3 DaY

5 DaY

10 DaY

3 Horizontal Sizes 10x10, 12x12, 16x16, 18x18, 24x24 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3

3 3 3 3 3 3

DAMPERS

107

insulated Control Damper


ICD-45 damper is typically used in applications where it is necessary to minimize the transfer of heat or cold penetration and reduce condensation.

StanDarD ConStrUCtion FeatUreS


Aluminum hat channel frame thermally broken with two polyurethane resin gaps and insulated on four sides with polystyrene Thermally broken aluminum airfoil blades with polyurethane foam Silicone blade and jamb seals Dual bearing with acetal inner sleeve and flanged outer bearing

Service chart
iCD-45

10 DaY
3
Greenheck Fan Corporation certifies that the model iCD-45 shown herein is licensed to bear the aMCa Seal. the ratings shown are based on tests and procedures performed in accordance with aMCa Publication 511 and comply with the requirements of the aMCa Certified ratings Programs. the

aMCa Certified ratings Seal applies to air performance ratings only.

Manual Balancing Dampers


Greenhecks manual balancing dampers are designed to regulate flow of air in an HVaC system. they are used to accomplish system balancing. each damper is equipped with a locking quadrant which fixes the damper blades in place after adjustment. these dampers are not intended to be used in applications as a positive shut off or for automatic control.

StanDarD ConStrUCtion FeatUreS

Galvanized Steel Fabricated to your size requirements

Service chart
SinGLe-BLaDe - MBD-10, 10 M MULti BLaDe - MBD-15 roUnD BLaDe - MBDr-50*

NeXt 3 DaY DaY


3 3 3 3 3 3

5 DaY
3 3

10 DaY
3 3

*note: MBDr-50 StoCK SiZeS aVaiLaBLe


round Blade - 6, 8, 10, 12 - in Wi and Ca.

oPtionS anD aCCeSSorieS


Stand-off brackets (accommodates for the additional thickness of insulated duct) Bronze bushings (MBD-15 only) Factory sleeves (MBD-15 only) (20 Ga.): 16, 21, 24 inches (16 Ga.): 16, 21 inches (14 Ga.): 16, 21 inches Transitions - oval, round, and rectangular (MBD-15 only)
108
DAMPERS

Stand-off Bracket

Manual Hand Quadrant

eXPLoDeD VieW oF StanD-oFF BraCKet


Extended Pin

industrial Dampers
industrial dampers are heavy duty construction for applications with high pressure and large air velocities.

ControL
industrial Control Dampers are heavy duty flange style dampers used to control airflow and provide shutoff.

Service chart

5 DaY

10 DaY

HeaVy DUty inDUStriaL (recommended for velocities up to 6000 fpm and 8 in. wg) HCD 100 Series - pressure class i - unpainted HCD 100 Series - pressure class i - painted 3 3 3

BaCKDraFt
industrial Backdraft Dampers are designed with heavy duty flange style frames to allow airflow in one direction and prevent reverse airflow.

Service chart
Unpainted HB MoDeLS Painted

5 DaY
3

10 DaY
3 3

Barometric relief Dampers


Barometric relief dampers are backdraft dampers having an adjustable start-open pressure. they are used on gravity ventilation systems or other low velocity applications.

SerViCe CHart
BarOMetriC reLieF eXtruDeD aLuMinuM recommended for velocities up to 2000 fpm or 2 in. wg MODeL FLanGe V* H* e* i* 5 DaY 10 DaY Br-10 none X X 3 3 Br-11 Discharge X X 3 3 Br-12 intake X X 3 3 Br-30 none X X 3 3 Br-31 Discharge X X 3 3 Br-32 intake X X 3 3 Br-40 none X X 3 3 Br-41 Discharge X X 3 3 Br-42 intake X X 3 3
*V - Vertical Mount *H - Horizontal Mount *e - exhaust (airflow up) *i - intake (airflow down)

DAMPERS

109

Backdraft Dampers
Greenhecks backdraft dampers are used in systems to allow airflow in one direction and prevent airflow in the opposite direction. For example, exhaust dampers allow airflow out of buildings only, preventing airflow into the building.

Service chart
Motor Packs end Switches

iN StOcK
3 3

3 DaY
3 3

5 DaY
3 3

10 DaY
3 3

PerForManCe
Performance capabilities up to 3000 fpm and 10 in. wg of static pressure.

StanDarD ConStrUCtion FeatUreS


Galvanized and extruded aluminum models Fabricated to your size requirements Stock sizes on some models
MateriaL MODeL
WD-100 WD-110 WD-120 WD-200 WD-210

FLanGe
none Discharge intake none Motor Side opposite Motor Side intake Discharge none none none Discharge intake none none Discharge intake none Discharge intake none Discharge intake none Discharge intake none Discharge intake none Discharge intake

V*

H*
X X X

e*
X X X X X X X X X

i*

SerViCe
Stock, 3 5, 10 3, 5, 10 3, 5, 10

StOCk SizeS
8x8, 10x10, 12x12, 16x16, 18x18, 24x24, 30x30

X X X X X X X

X X X

X X X

Stock, 3, 5, 10 3, 5, 10 3, 5, 10 3, 5, 10 Stock, 3, 5, 10 Stock, 3, 5, 10

8x8, 10x10, 12x12, 14x14, 16x16, 18x18, 24x24, 30x30

recommended for velocities up to 2000 fpm or 2 in. wg

GaLVanizeD

WD-220 WD-300 WD-320 WD-330 WD-400 WD-410 WD-420 WD-430 WDr-53 eS-10

10x10, 12x12, 14x14, 16x16, 18x18, 20x20, 22x22, 26x26, 32x32, 38x38 9x9, 12x12, 14x14, 16x16, 18x18, 20x20, 23x23, 24x24, 35x35

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X

3, 5, 10 Stock, 3, 5, 10 3, 5, 10 3, 5, 10 10 8x8, 10x10, 12x12, 14x14, 16x16, 18x18, 20x20, 24x24, 30x30

X X X

StanDarD DutY eXtruDeD aLuMinuM

eS-11 eS-12 eS-30 eS-31 eS-32 eS-40 eS-41 eS-42 eM-10

X X X

1, 3, 5, 10

recommended for velocities up to 2000 fpm or 2 in. wg

MeDiuM DutY eXtruDeD aLuMinuM

eM-11 eM-12 eM-30 eM-31 eM-32 eM-40 eM-41 eM-42

X X X

1, 3, 5, 10

recommended for velocities up to 3000 fpm or 10 in. wg

*V - Vertical Mount *H - Horizontal Mount *e - exhaust (airflow up) *i - intake (airflow down)

110

DAMPERS

Louvers
For complete louver product information refer to catalog Louver Products (Severe Duty, Stationary, Operable) or contact your local representative.

Drainable Blade
Drainable blades offer excellent resistance to water penetration. EDD Series incorporates dual drainable blades for additional water capture. Models ESD-435 and ESD-635 lend 56% and 59% free area respectfully.

Service chart all Mill FiNiSh rectangular or Square Models PaiNteD FiNiSheS**
eDD-401, 601 eSD-202, 403, 435, 603, 635

NeXt 3 5 10 DaY* DaY DaY DaY 10 12 17 8 DaY DaY DaY DaY


P P P P P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica, Baked Enamel,
Anodize, and a variety of industrial finishes

eSD-435

eDD-401

Drainable Head
Drainable head member improves ability to prevent water penetration due to an additional drain gutter designed to capture water. Models EDJ-430 and EDK-430 have optional 30 degree blades designed to maximize free area. Model ESID-430 is an air intake/ discharge louver which helps prevent the short cycling of air.

Service chart all Mill FiNiSh rectangular or Square Models PaiNteD FiNiSheS**
EDJ-202, 401, 430, 601 eDK-402, 430, 602 eSiD-430

NeXt 3 5 10 DaY* DaY DaY DaY 10 12 17 8 DaY DaY DaY DaY


P P P P P P P P P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica, Baked Enamel,
Anodize, and a variety of industrial finishes

eDJ-401

eDk-402

eSiD-430
LOUVERS

111

nondrainable
Traditional stationary J or K blade styles. K blade has as additional offset or rain hook for extra protection against water penetration. Design incorporates hidden mullions for continuous blade appearance when multi-width sections are needed.

Service chart all Mill FiNiSh rectangular or Square Models PaiNteD FiNiSheS**
ESJ-202, 401, 602 eSK-402, 602 eSJ-401 eSk-402

NeXt 3 5 10 DaY* DaY DaY DaY 10 12 17 8 DaY DaY DaY DaY


P P P P P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

recessed Mullion
Recessed Mullion design offers better blade alignment for a true continuous blade appearance. Provides more structural integrity between multi-wide sections. Easier installation with minimal field adjustments. Models are easier to seal in field and thermal expansion is accounted for within the design.

Service chart all Mill FiNiSh rectangular or Square Models PaiNteD FiNiSheS**
ESJ-401RM, 602RM eSK-402rM, 602rM eSJ-401rM eSk-402rM

NeXt 3 5 10 DaY* DaY DaY DaY 10 12 17 8 DaY DaY DaY DaY


P P P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

thinline
Recessed Mullion design offers better blade alignment for a true continuous blade appearance. Provides more structural integrity between multi-wide sections. Easier installation with minimal field adjustments. Models are easier to seal in field and thermal expansion is accounted for within the design.

Service chart all Mill FiNiSh rectangular NeXt 3 5 10 or Square Models DaY* DaY DaY DaY 10 12 17 PaiNteD FiNiSheS** 8 DaY DaY DaY DaY
eSF-145 ESJ-150 eSF-145 eSJ-150 eSU-130, 150 eSU-130S, 150S
P P P P P P P P P P P P P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

eSu-150
112
LOUVERS

eSu-130S

adjustable Blade
Design incorporates operable blades that can be Service chart opened or closed to protect air intake and exhaust all Mill FiNiSh rectangular openings in exterior building walls. Louver blades are center pivoted and can be operated or Square Models manually or by electric or pneumatic actuators. PaiNteD FiNiSheS** EAD and EAH Series offer concealed blade linkage. EADC Series offer both concealed blade linkage and a eaD-401, 601 concealed electric actuator. Model EAH-690 provides 70% free area when blades eaDC-401, 601 are in full 90 degree open position. eaH-401, 690

NeXt 3 5 10 DaY* DaY DaY DaY 10 12 17 8 DaY DaY DaY DaY


P P P P P P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

eaH-401

eaH-690

eaDC-401

eaD-401

Combination Louver/Damper
Maintains a stationary appearance when adjustable blades are closed. ECD Series offer exposed on-blade linkage. EAC Series and Model EACN-601 offer concealed linkage and center pivot operable blades. Model EACA-601 incorporates airfoil blades. EACC Series offer both concealed blade linkage and concealed electric actuator. GCE and GCI Series require an exhaust or intake fan for proper operation.

Service chart all Mill FiNiSh rectangular NeXt 3 or Square Models DaY* DaY 10 PaiNteD FiNiSheS** 8 DaY DaY
eaC-401, 601 eaCa-601 eaCC-401, 601 eaCn-601 eCD-401, 601 GCe-202, 402 GCi-202, 402
P P P P P P P P P P P P

5 DaY 12 DaY
P P

10 DaY 17 DaY
P P P

P P P P

P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

eaC-401

eaCa-601

eaCC-401

eaCn-601

eCD-401

GCi-402

GCe-402
LOUVERS

113

Sightproof
Louvers are designed to prevent visual see through and Service chart can be applied as air intake or discharge louvers or can all Mill FiNiSh rectangular be applied as louvered equipment screens. or Square Models SES Series most economical of all sightproof models. SEH Series incorporates a drainable head member for PaiNteD FiNiSheS** increased protection against water penetration. SeD-202, 401, 501 SED Series offer both a drainable head member and drainable blades for maximum protection against water SeH-202, 401 penetration. Model SED-501 offers 57% free area. SeS-202, 401 SEV Series offer a vertical sightproof blade design.

NeXt 3 5 10 DaY* DaY DaY DaY 10 12 17 8 DaY DaY DaY DaY


P P P P P P P P P P P P P P P P

SeV-401, 501

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica, Baked
Enamel, Anodize, and a variety of industrial finishes

SeS-401

SeV-401

SeH-401

SeD-401

acoustical
Acoustically insulated blades provide sound absorption from escaping noise. Available in formed aluminum or steel material. AFJ Series most economical of all acoustical models. Model AFA-801offers the highest free area and lowest airflow resistance and designed with acoustical blades. Model AFS-120 offers the best sound absorption performance and incorporates sightproof blades.

Service chart all Mill FiNiSh rectangular or Square Models PaiNteD FiNiSheS**
aFa-801 AFJ-601, 801, 120 aFS-120

NeXt 3 5 10 DaY* DaY DaY DaY 10 12 17 8 DaY DaY DaY DaY


P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

aFa-801

aFJ-801

aFS-120

114

LOUVERS

Fabricated
Fabricated from galvanized steel and are low-cost compared to extruded aluminum models. All fabricated models are available in stainless steel material. FSJ and FDS Series have stationary blades only. FAD and FAJ Series are adjustable blade models.

Service chart all Mill FiNiSh rectangular NeXt 3 5 10 or Square Models DaY* DaY DaY DaY 10 12 17 PaiNteD FiNiSheS** 8 DaY DaY DaY DaY
FaD-402, 602, 635 FAJ-402, 602 FDS-402, 602 FSJ-402, 602
P P P P P P P P P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

FaD-402

FaJ-402

FSJ-402

FDS-402

Wind-Driven rain
Louvers are designed to prevent visual see through and can be applied as air intake or discharge louvers or can be applied as louvered equipment screens. SES Series most economical of all sightproof models. SEH Series incorporates a drainable head member for increased protection against water penetration. SED Series offer both a drainable head member and drainable blades for maximum protection against water penetration. Model SED-501 offers 57% free area. SEV Series offer a vertical sightproof blade design.

Service chart all Mill FiNiSh rectangular NeXt 3 5 10 or Square Models DaY* DaY DaY DaY 10 12 17 PaiNteD FiNiSheS** 8 DaY DaY DaY DaY
eHH-201, 401, 501, 601, 701 eVH-201, 401, 602, 801
P P P P P P P P

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

eHH-401

eVH-401

LOUVERS

115

Florida Product approved


All mechanically fastened Florida Product Approved models comply with TAS-202, Uniform Static Pressure Test (aStMe330). Models also comply with TAS-201 Large Missile Impact Test (ASTM E1996), TAS-203 Cyclic Wind Pressure Load Test with optional welded construction. Approved for use in Floridas High Velocity Hurricane Zone if Miami-Dade Notice of Acceptance is not required.

Service chart all Mill FiNiSh rectangular NeXt 3 5 10 or Square Models DaY* DaY DaY DaY 10 12 17 PaiNteD FiNiSheS** 8 DaY DaY DaY DaY
AFJ-601X eSD-435X, 635X eHH-501X eSD-435X
Florida Product Approved No.: FL6876.3

P P P P P P P P P P

eSD-635X
Florida Product Approved No.: FL6876.4

eVH-602X

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

eVH-602X
Florida Product Approved No.: FL7494.1

eHH-501X
Florida Product Approved No.: FL6876.2

aFJ-601X
Florida Product Approved No.: FL6876.1

Miami-Dade Qualified
Use within Floridas High Velocity Hurricane Zone when a Miami-Dade notice of acceptance is required. All models comply with Miami-Dade structural test protocols taS-201, Large Missile impact test (aStM e1996); taS-202, Uniform Static Pressure test (aStM e330) and taS-203, Cyclic Wind Pressure test.

Service chart all Mill FiNiSh rectangular NeXt 3 5 10 or Square Models DaY* DaY DaY DaY 10 12 17 PaiNteD FiNiSheS** 8 DaY DaY DaY DaY
eSD-635D eHH-601D eSS-501D * Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or 50%), Mica,
Baked Enamel, Anodize, and a variety of industrial finishes

P P P

eSD-635D
Florida Product Approved No.: FL10088.3 NOA NO.: 07-1015.06 MODel MiaMi StOcK Size 12x12 18x18 24x24 30x30 36x36 48x48

eSD-635D

eSS-501D
Florida Product Approved No.: FL8923.1 NOA NO.: 08.0611.08

eHH-601D
Florida Product Approved No.: FL10088.1 NOA NO.: 08-0229.06

116

LOUVERS

Louvered Penthouses
the low silhouette louvered penthouses are designed for intake (Model WiH) or relief (Model WrH) applications with either natural gravity or positive pressure systems. these units feature a storm-proof aluminum louver with mitered corners and clean horizontal lines. The design affords lower pressure drops while maintaining low hood heights. Allaluminum construction assures lasting durability and appearance. removable cover is lined with fiberglass to prevent condensation. Louvers are mounted 4 in. from the roof opening for added weather protection. each unit is factory made into four side sections and one cover. the units are shipped in pre-assembled sections that are easy to assemble on the jobsite without special tools.

Service chart PaiNteD FiNiSheS**


All Models and Sizes Sizes up to 48 x 48 in.

5 DaY 12 DaY*
P

10 DaY 17 DaY*
P P

StanDarD ConStrUCtion FeatUreS

* Quantity Limit = 10 ** 2-Coat KYNAR 500/ HYLAR 5000 (70% or

Louvers of extruded aluminum (.080 in) industrial finishes Removable cover(s) lined with fiberglass insulation (as standard) MoDeL: W (LoUVereD PentHoUSe) All units shipped knocked down B .5 in. Galvanized mesh birdscreen Recommended roof opening dimension is at least 21/2 in. larger than damper size

50%), Mica, Baked Enamel, Anodize, and a variety of

oPtionS anD aCCeSSorieS


Aluminum birdscreen Aluminum or galvanized roof curbs (See pages 38-39) Curb seal Gravity and motorized dampers 1 in. hood insulation Greenheck coatings (See coatings page 119)

DiMenSionaL Data
MODeL LOuVereD PentHOuSe Size ranGe LiMitS a 12 in. - 80 in. B C 12 in. - 120 in. 121/4 in. - 493/4 in.

Throat A Curb Cap

For complete product information refer to catalog Model WIH Intake and WRH Relief, or contact your local representative.

LoUVereD PentHoUSe - intaKe anD reLieF PerForManCe Data (Per Square Foot of throat area)
intake reLieF StatiC PreSSure DrOP tHrOat VeLOCitY StatiC PreSSure DrOP tHrOat VeLOCitY .008 200 .024 400 .017 300 .038 500 .03 400 .06 600 .048 500 .075 700 .069 600 .097 800 .094 700 .123 900 .123 800 .152 1000 .156 900 .184 1100 .192 1000 .22 1200

Brick Vents
a permanent means of ventilation for crawl spaces, hung ceilings, incinerator rooms, chimney flues, foundations, pipe spaces, and corridors. Many standard sizes and finishes available.

Service chart
BVe 8 8 x 7 4 BVe 12 x 734 BVe 1558 X 734 BVe 1612 X 734 All other BVE sizes All BVF sizes All BVC sizes
1 3

Mill FiNiSh aNODizeD*


QD Stock QD Stock QD Stock QD Stock 5 Day 5 Day 5 Day 5 Day 5 Day 5 Day 5 Day 5 Day 5 Day na

PaiNteD**
8 Day 8 Day 8 Day 8 Day 12 Day 12 Day 12 Day***

* 204-R1, medium, dark, by others ** Primer, Baked Enamel, Acroflur, Kynar, Kynar-3 coat, Mica - all done at Greenheck
*** Baked Enamel paint only

LOUVERS

117

options and accessories


Mounting options
the mounting options shown on this page (type a and B) relate to the Selection Guide For Vibration isolation as published in the latest aSHrae applications handbook, HVaC applications-Sound and Vibration Control.

DireCt MoUnt - tyPe a

Spring

rubber

no base required. isolators are attached directly to equipment. Direct isolation can be used if equipment is unitary and rigid without the use of additional support. Direct isolation is not recommended for equipment having large overhung loads (e.g. motors on arr. 9 fans). if there is any doubt that equipment can be supported directly on isolators, use rails, bases or consult the factory.

StrUCtUraL BaSeS - tyPe B2


rubber Mount

Shown W/o isolators or Brackets


W/Height Saving Bracket

Spring Mount

Structural steel bases consist of structural steel members welded into a rigid one piece base. Motor slide rails are included where applicable. Bases are required for all arr. 1 and 3 fans with independently mounted motors. Structural steel bases are available without isolators, with rubber mounts or with spring mounts. all structural steel bases with spring mounts incorporate height saving brackets.
Quick Build bases are standard dimensions with factory supplied motor and drives.

reStraineD SPrinG MoUntS - tyPe 4a 1in. DeFLeCtion


restrained spring isolators consist of laterally stable, freestanding springs assembled into a steel housing. these assemblies are designed for vertical and horizontal motion restraint. restrained spring isolators can be used for blocking during equipment installation and are provided with leveling bolts. Springs provide 50% overload capacity and are color coded or identified to indicate load capacity. restrained spring mounts are recommended for equipment subject to wind loading or large torquing forces.

rUBBer MoUntS - tyPe 2 1/4 in. & 1/2 in. DeFLeCtion


neoprene mountings consist of a steel top plate and base plate completely embedded in colored (oil-resistant) neoprene for easy identification of capacity. neoprene mountings are furnished with a tapped hole in the center. this enables the equipment to be bolted securely to the rubber mount.

HoUSeD SPrinG MoUntS - tyPe 4B 1 in. DeFLeCtion


Housed spring isolators consist of steel springs assembled into a telescoping housing with a top mounted adjusting bolt and an acoustical nonskid base. Housed spring isolators include resilient inserts to prevent metal-to-metal contact and provide snubbing for side loads. Springs provide an additional 50% overload capacity and are color coded or identified to indicate load capacity.

Free-StanDinG oPen SPrinG MoUntS tyPe 3 1 in. DeFLeCtion


Free-standing spring isolators are unhoused laterally stable steel springs. they provide a minimum horizontal stiffness of 0.8 times the rated vertical stiffness and provide an additional 50% overload capacity. These isolators are equipped with a top mounted adjusting bolt and an acoustical nonskid base. Springs are color coded or identified to indicate load capacity.

MOuntinG SeLeCtiOn arr


1 3 4 9 10

Fan tYPe
aF/BiSW iPa/o/W aF/BiSW aF/BiDW SFD aF/BiSW iPa/o/W SFB/SWB aF/BiSW aF/BiSW iPa/o/W

DireCt MOunt (tYPe a)

X X X X X

StruCturaL BaSe (tYPe B2) X X X X X X X X X

118

OPTIONS AND ACCESSORIES

Coatings
Greenheck offers a choice of either protective or decorative coatings for many of the quick Build products. Protective coatings are available in a choice of four electrostatic applied powders. Powders available range from polyester urethanes to high performance epoxy providing an available selection for most environments. Powder coatings offer a number of advantages over most wet coatings. electrostatic painting involves applying a dry, charged particle to a grounded sheet metal. the results are uniform coverage and thickness with heavier coverage in the high charge areas (edges, corners, and pockets), that are difficult to reach with wet paint. another advantage is environmental friendliness. PerForManCe CoatinGS the following is a brief description of the protective coatings offered. Complete descriptions and protective qualities can be found in GREENHECKS SPECIAL CoAtING ENGINEERING BuLLEtIN (or consult your local representative).

PoWDer CoatinGS
Permatector
Permatector

Permatector is the standard coating applied to all steel fans. typical applications include corrosion resistance in indoor and outdoor environments. *040 gray (standard)

Decorative Coatings
For projects where the fan exterior appearance is important and additional chemical resistance is not required, customers can choose from 16 standard decorative colors.
NotE: Colors are subject to change.

Hi-Pro Polyester*

Hi-Pro Polyester (Used in lieu of air Dry Phenolic) this coating is resistant to salt water, chemical fumes, and moisture in more corrosive atmospheres. it has superior chemical resistance, excellent abrasion and outdoor UV protection. this coating has protective qualities that exceed air Dried Heresite.
*Note: Standard Hi-Pro Polyester Lab Exhaust products are 041 gray

Heat Cured enamels

epoxy
epoxy

epoxy has excellent moisture resistance and moderate to good chemical resistance. Greenhecks epoxy is light tan in color so it will resist fading and chalking when exposed to sunlight.

Decorative coatings are heat cured enamels applied either as wet paints or electrostatic powders. the range of colors offered provides for a color selection to meet most exterior requirements.

industrial epoxy
industrial epoxy

industrial epoxy is a high performance epoxy with excellent chemical resistance in interior applications to a wide variety of chemicals including acids, caustics, solvents, and high moisture.
MarBLe Gray DeSert SanD HaMPton BroWn HoriZon BLUe CaPri BLUe DarK Gray CHarCoaL

iVory SPartan WHite

taUPe

MaCHine tooL Gray

MeDiUM BronZe

FLat BLaCK

CLaSSiC BronZe

GLoSS BLaCK

NotE: Colors are subject to change.

OPTIONS AND ACCESSORIES

119

electrical accessories
Speed controls are available in two models for use with shaded pole and open permanent split capacitor motors in 115 volt single-phase only. Model 5W - For applications up to 5.0 amps. requires 2 x 4 handy box by others. Model 10W - For applications up to 10.0 amps. requires 4 x 4 handy box by others.

Fan SPeeD ControL

DiSConneCt SWitCHeS

For safety in servicing fans not equipped with factory mounted disconnects, switches are available in five models. each model includes a switch assembly, handy box and cover plate.
StanDarD

MODeL GtD the Model GtD time Delay Switch is available for keeping a fan or light operating for an extended period of time after the initiating switch has been turned off. the GtD assembly consists of a single-pole, single-throw switch, a timer and a cover plate.

tiMe DeLay SWitCH

WeatHerPrOOF MODeL n1tS-1 n1tS-2 n1tS-3 n1tS-4 n1tS-6 n3rtS-1 n3rtS-6

Weatherproof Disconnect Switches in neMa rated weatherproof boxes for positive electrical shutoff and safety in servicing fans. neMa3r toggle style switch models are listed below.
HP/VOLtS/PH StanDarD up to 1/2 120V up to 1 120V up to 2 120V up to 2 200/277 up to 71/2 200/600 WeatHerPrOOF up to 1/2 120V up to 7 200/600 Fire Stat

ManUaL Starter SWitCH

1ph 1ph 1ph 1ph 3ph 1ph 3ph

Manual motor starting switches are available in five models. all models are UL/cUL Listed, HP rated, specification grade and feature neoprene rockers for quiet operation. Model MS-16 includes a pilot light. all models require a handy box by others.
SPeeDS 1 1 1 1 3 MODeL MS-1 MS-16 w/pl MS-4 MS-6 MS-15 1/2 1/2 2 2 1/6 HP/VOLtS/PH 120V 120V 200/277 200/600 120V 1ph 1ph 1ph 3ph 1ph

tYPe ii

Limit control temp. range 120-220 auto reset (Fire-Stat) 120V/8.0 amps - 220V/4 amp capacity. air Stat. adjustable temperature on (close circuit) ranging from 120F to 200F with off (open circuit) at 100F. 120V/8.0 amps - 220V/4 amp capacity. Contacts close on temperature rise. adjustable for temperature range 30-110 degrees F. rating to 120V/16 amps.

tYPe iii reVerSe aCtinG tHerMOStat

Need a replacement part for your fan?

Call our parts department toll free 1-800-355-5354 (for parts orders only) with fan model and serial number (located on fan name tag)

120

OPTIONS AND ACCESSORIES

Fan Fundamentals
introduction to Fan SeLeCtion
this is a guide to the most basic fan sections, all of which enable you to select the right fan for the job. it will answer the following questions (and more): What is a SONE? How are model numbers and performance tables used to select a fan? How are direct drive and belt driven fans different? What types of motors are used with these fans? the goal is to understand and use the Greenheck literature as an important tool in filling a customers fan order.

Terms
cfm Ps sone Bhp hp rpm tS aMCa Cubic Feet Per Minute. a measure of airflow. Static Pressure. resistance to airflow measured in inches of water gauge. a measure of loudness. one sone can be approximated as the loudness of a quiet refrigerator at a distance of 5 feet. Sones follow a linear scale, that is, 10 sones are twice as loud as 5 sones. Brake Horsepower. a measure of power consumption. Used to determine the proper motor horsepower and wiring. Horsepower. Used to indicate a fans motor size. revolutions Per Minute. Measure of fan speed. tip Speed. the speed of the tip of a fan wheel or prop measured in feet per minute. air Movement & Control association. A nationally recognized association which establishes standards for fan testing and performance ratings. aMCa also license air volume and sound certified ratings.

MoDeL DeSiGnation
For Greenheck belt drive models, the model designation tells the model type, size and the motor hp. eXaMPLe: GB-090-6 Model is GB hp is 1/6 nominal Wheel Dia. 9 in.
BeLt DriVe Suffix Motor hp 1/6 6 4 1/4 1/3 3 5 1/2 7 3/4 10 1 15 11/2 20 2 30 3 50 5 75 71/2 DireCt DriVe Suffix Fan rpm a 1725 B 1140 C 860 D 1550 G 1300 e 1050 F 880 P 1625

For direct drive units, the model designation tells the model type, the size and the motor/fan rpm.
eXaMPLe: G-121-B Model is G rpm is 1140 nominal Wheel Dia. 12 in.

this table lists model designation suffixes for motor horsepower and fan rpm.

Motor inForMation (Belt Drive only)


When specifying a belt drive fan, the model designation does not completely describe the unit. additional information about the motor is necessary. these items are listed below: MOtOr enCLOSure This will be either Open (open, drip proof), TE (totally enclosed) or EXP (explosion-resistant). Open is the most common and will be supplied unless otherwise specified.

SPeeDS Motors are available in either single-speed or two speed. Single-speed motors are 1725 rpm. two speed motors will be 1725/1140 rpm. Single-speed will be supplied unless otherwise specified. eLeCtriCaL CHaraCteriStiCS Voltage and phase. Voltage can be 115, 208, 230 or 460. Phase is either single-or 3 phase. a 115 volt, singlephase motor is shown as 115/1. typically, motors of 1/2 hp and less are single-phase. Motors of 3/4 hp and greater are 3 phase. Typical moTor Tag Suffix Letter Motor Speed D 1550 rpm G 1300 rpm e 1050 rpm electrical instructions Wiring Connections White to L1 Black to L2 White to L1 Blue to L2 White to L1 red to L2

DireCt DriVe
Selection of direct drive fans (those with the motor shaft connected to the fan wheel or propeller) is nearly the same as belt drive selection. However, there are two differences worth noting. Where belt drive fan speed can be altered by adjusting the motor pulley, direct drive fans (since they have no pulleys) must use a different method. 1 to adjust a direct drive fans speed (also motor speed) or to provide a means of meeting an exact performance requirement, a speed control can be furnished. Speed controls vary the voltage supplied to the fan and slow it down; a principle similar to the way dimmer light switches work.

the three speeds are 1550 rpm (D), 1300 rpm (G) and 1050 rpm (e). Changing a motor lead is all that is necessary to change speeds. When selecting a model with a 3 speed motor, it is recommended that the G speed be chosen whenever possible. this is the middle speed, which gives the greatest flexibility in air volume because airflow can be increased or decreased simply by changing a motor lead.

2 Models CUE and CW, sizes 060-095 and Model SQ, sizes 60-95, are provided with 115 volt, 60 cycle motors.
FAN FUNDAMENTALS

121

introduction to Fan SeLeCtion


Motor HorSePoWer
the motor horsepower for direct drive fans is always sized by Greenheck and does not require further consideration. For belt drive models, the catalog identifies which horsepower is recommended. However, there are times when it is wise to bump the horsepower one size. For example, the hp recommended for the GB-180 at 810 rpm (2375 cfm @ .5 Ps) is 1/3 hp. although a 1/3 hp motor is recommended, it is not necessarily a good motor selection for this application. our static pressure of 0.5 in. was only an estimate. it may actually turn out to be .625 in. if this is the case, we will need a 1/2 hp motor because our fan will have to run at almost 810 rpm (refer to performance box - 2052 cfm at 0.625 in. Ps). therefore, choosing a 1/2 hp motor in this case is exercising good judgement. the complete model designation for this application is GB-180-5.
nOte: the GB-180-5 has an rpm range of 700-940. this means that if the static pressure is less than estimated, say 0.25 in. Ps, the fan can be slowed down to accommodate this condition.

BeLt DriVe
one advantage of choosing a belt drive over a direct drive is that it is capable of adjusting the fan rpm, which enables the fan to move more air if necessary. Motor pulleys are adjusted by loosening the set screw and turning the top half of the pulley (see illustrations at right). this causes the pulley diameter to change, which results in changing the fan rpm.
Belt opening the pulley decreases fan rpm. Closing the pulley increases fan rpm.

aPPLiCationS
Ventilating a building simply replaces stale or foul air with clean, fresh air. although the ventilation process is required for many different applications, the airflow fundamentals never change: UnDeSIReD aIR OUt, FReSH aIR In the key variables that do change depending on applications are the fan model and the air volume flow rate (cfm). other considerations include the resistance to airflow (static pressure or Ps) and sound produced by the fan (Sones). occasionally, a customer will require a fan to perform a particular function, yet does not know which model to use or even what cfm is necessary. in this case, some fan specification work must be done. Fan specification is usually not a precise science and can be done confidently when the fan application is understood. Based on the application, four parameters need to be determined. they are: Fan Model Cubic Feet per Minute (cfm) Static Pressure (Ps) Loudness limit (sones)

the information that follows will help walk you through this type of problem and enable you to select the right fan for the job.

Fan MoDeL
Fans all perform the basic function of moving air from one space to another. But the great diversity of fan applications creates the need for manufacturers to develop many different models. each model has benefits for certain applications, providing the most economical means of performing the air movement function. the trick for most users is sorting through all of the models available to find one that is suitable for their needs.

ProPeLLer vs. CentriFUGaL WHeeL


Propeller fans provide an economical method to move large air volumes (5,000+ cfm) at low static pressures (0.50 in. or less). Motors are typically mounted in the airstream which limits applications to relatively clean air at maximum temperatures of 110F. Centrifugal fans are more efficient at higher static pressures and are quieter than propeller fans. Many centrifugal fan models are designed with motors mounted out of the airstream to ventilate contaminated and high temperature air.

122

FAN FUNDAMENTALS

introduction to Fan SeLeCtion


DeterMininG CFM
after the model is known, the cfm must be determined. Consult local code requirements or the table below for suggested air changes for proper ventilation. the ranges specified will adequately ventilate the corresponding areas in most cases. However, extreme conditions may require Minutes per Change outside of the specified range. To determine the actual number needed within a range, consider the geographic location and average duty level of the area. For hot climates and heavier than normal area usage, select a lower number in the range to change the air more quickly. For moderate climates with lighter usages, select a higher number in the range. to determine the cfm required to adequately ventilate an area, divide the room volume by the appropriate Minutes per Change value.

SuGGeSteD air CHanGeS FOr PrOPer VentiLatiOn


cfm = room Volume Min./Chg.
area assembly Hall attic auditorium Bakery Bar Barn Boiler room Bowling alley Cafeteria Church Classroom Club room Min./Chg. 3-10 2-4 3-10 2-3 2-4 12-18 1-3 3-7 3-5 4-10 4-6 3-7 area Dance Hall Dining room Dry Cleaner engine room Factory Foundry Garage Generator room Gymnasium Kitchen Laboratory Laundry

room Volume = L x W x H (of room)


Min./Chg. 3-7 4-8 2-5 1-3 2-7 1-5 2-10 2-5 3-8 1-5 2-5 2-4 area Machine Shop Mill office Packing House Projection room recreation room residence restaurant restroom Store transfer room Warehouse Min./Chg. 3-6 3-8 2-8 2-5 1-2 2-8 2-6 5-10 5-7 3-7 1-5 3-10

SaMPLe ProBLeM
a building requires an exhaust fan to ventilate a general office (see diagram below) which measures 30 ft. x 40 ft. x 8 ft. the office is often crowded. SOLutiOn: the total room volume is 30 ft. x 40 ft. x 8 ft. = 9600 cubic feet. From the chart, the range for general offices is 2-8 minutes per change. Since the office has heavier than normal usage, 4 minutes per change is recommended. therefore, the required exhaust is: 9600 ft3 = 2400 cfm 4 min.
Exhaust fan to be sized

Since the air to be exhausted is relatively clean, this is an ideal application for a model GB fan. nOte: in this example, make-up air was provided through a set of louvers at the wall farthest from the exhaust fan. if there were no provisions for make-up air in this room, a supply fan would also have to be sized. The supply cfm should equal the exhaust cfm. Supply fan location should be as far as possible from the exhaust fan.

30 ft. Louvers to supply Makeup air 8 ft. 40 ft.

FAN FUNDAMENTALS

123

introduction to Fan SeLeCtion


DeterMininG StatiC PreSSUre (Ps)
the pressures generated by fans in ductwork are very small. yet, accurately estimating the static pressure is critical to proper fan selection. Fan static pressure is measured in inches of water gauge. one pound per square inch is equivalent to 27.7 in. of water gauge. Static pressures in fan systems are typically less than 2 in. of water gauge, or 0.072 Psi. the drawing below illustrates how static pressures are measured in ductwork with a manometer. a pressure differential between the duct and the atmosphere will cause the water level in the manometer legs to rest at different levels. this difference is the static pressure measured in inches of water gauge. in the case of the exhaust fan below, the air is being drawn upward through the ductwork because the fan is producing a low pressure region at the top of the duct. this is the same principle that enables beverages to be sipped through a straw. the amount of static pressure that the fan must overcome depends on the air velocity in the ductwork, the number of duct turns (and other resistive elements), and the duct length. For properly designed systems with sufficient make-up StatiC in the table below can be air, the guidelinesPreSSure GuiDeLineS used for estimating static pressure: StatiC PreSSUre GUiDeLineS nonducted Ducted Fittings kitchen Hood exhaust iMPortant! 0.05 in. to 0.20 in. 0.2 in. to 0.40 in. per 100 feet of duct (assuming duct air velocity falls within 1000-1800 feet per minute) 0.08 in. per fitting (elbow, register, grill, damper, etc.) 0.625 in. to 1.50 in.

Static pressure requirements are significantly affected by the amount of make-up air supplied to an area. insufficient make-up air will increase static pressure and reduce the amount of air that will be exhausted. remember, for each cubic foot of air exhausted, one cubic foot of air must be supplied.

exhaust Fan

Ductwork Damper

Airow to exhaust fan

4 ft.

Airow Duct 1 in.

Atmospheric Pressure Manometer Water

6 ft.
Grill Airow out of restaurant

to calculate the system losses, one must know the ductwork system configuration (see Ductwork figure). This duct is sized for air velocities of 1400 feet per minute. referring to the static pressure chart, that will result in about 0.3 in. per 100 feet. Since we have 10 feet of total ductwork, our pressure drop due to the duct is:
.3 in. 100 ft. x 10 ft. = .03 in.

there is also a 0.08 in. pressure drop for each resistive element or fitting. For this example, there are 5 fittings: one grill, two duct turns, one damper and louver in the wall of the office. the total pressure drop for fittings is: 5 x 0.08 in. = 0.4 in. therefore, the total pressure drop is: 0.03 in. + 0.40 in. = 0.43 in.*

* nOte: For convenience in using selection charts, round this value up to the nearest 1/8 in., which would be 0.50 Ps.

124

FAN FUNDAMENTALS

introduction to Fan SeLeCtion


Fan LaWS
in a steady-state system, as the fan rpm changes, cfm, Ps and BHp (horsepower) also change. the equations below, known better as fan laws, show the relationship between these performance parameters. nOte: A 25% increase in rpm results in a 95% increase in horsepower. Considering this, initial fan selections should be sized with motor horsepowers greater than necessary if any increase in fan rpm is likely in the future.
cfmnew =

Psnew

Bhpnew

ADJUSTING FAN PERFORMANCE


there is a direct relationship between cfm and rpm within a system. Doubling the fan rpm will double-the cfm delivered. sample: the example at the right shows a fan curve at 700 rpm which had an operating point of 1000 cfm at 0.25 in. Ps. What rpm is required to move 2000 cfm through the same system? solution: Within a system, cfm is directly related to rpm. therefore, the new rpm (r p m 2 ) can be determined from the following equation:
rpm2 = rpm1 x

( ( (

rpmnew rpmold rpmnew rpmold rpmnew rpmold

) ) )

cfmold

x
3

Psold

this equation relates horsepower to rpm. the change in horsepower can be determined when the rpm is increased by 25%. This is shown below:

Bhpold

Bhpnew

= (1.25)

Bhpold

1.95

Bhpold

Ps2

Ps1

( (

rpm2 rpm1

) )

For our example,


Ps2 = 0.25 in. x

1400 rpm 700 rpm

= 1.0 in.

cfm2 cfm1

this verifies the operating point on the 1400 rpm curve (2000cfm at 1.0 in. Ps). With this example, it should be clearhow cfm, rpm and Ps tie together in a steady-state system. Varying operating points

= 700 rpm x

2000 cfm 1000 cfm

1400 rpm

referring to figure at right, this results in sliding up the system resistance curve from 700 rpm to 1400 rpm. notice that as we doubled our airflow from 1000 cfm to 2000 cfm, the Ps went up from 0.25 in. to 1.0 in. it must be kept in mind that we are not changing the system, only increasing fan speed. therefore, we must remain on the system resistance curve. Within a system, Ps varies as the square of cfm. Since cfm and rpm are directly proportional, an equation relating Ps and rpm can be derived as follows:

Example

Solution

SoUnD LeVeLS
in many cases, the sound generated by a fan must be considered. For the fan industry, a common unit for expressing sound pressure level is the sone. in practical terms, the loudness of one sone is equivalent to the sound of a quiet refrigerator heard from five feet away in an acoustically average room. Sones are a linear measurement of sound pressure levels. For example, a sound level of 10 sones is twice as loud as 5 sones. SuGGeSteD LiMitS FOr rOOM LOuDneSS
Sones
1.3-4 1.7-5 2-6 2.5-8 3-9 4-12 5-15 7-21 12-36 15-50 25-60

refer to the Suggested Limits for room Loudness chart to determine the acceptable sone range for the application. as a general guideline, choose a fan that has a sone value within the range specified. nOte: rooms with a hard construction (concrete block, tile floors, etc.) reflect sound. For these rooms, select fans on the lower end of the range. rooms with soft construction or those with carpeting and drapes, etc., absorb sound. For these rooms, fans near the higher end of the range may be selected. For example, an exhaust fan for an office in the Suggested Limits for Room Loudness chart below says that offices should have a loudness range from 4 to 12 sones. Comparing a GB-141, GB-161 and GB-180 fan for approximately 3100 cfm at 0 Ps only the GB-180 has a sone value of less than 12. therefore, the GB-180 is the best selection for this application.

DBa

32-48 36-51 38-54 41-58 44-60 48-64 51-67 56-72 64-80 67-84 74-87

Private homes (rural and suburban) Conference rooms Hotel rooms, libraries, movie theatres, executive offices Schools and classrooms, hospital wards, and operating rooms Courtrooms, museums, apartments, private homes (urban) restaurants, lobbies, general open offices, banks Corridors and halls, cocktail lounges, washrooms and toilets Hotel kitchens and laundries, supermarkets Light machinery, assembly lines Machine shops Heavy machinery

From AMCA Publication 302 (Application of Sone Ratings for Non Ducted Air Moving Devices with Room-Sone-dBA correlations).
FAN FUNDAMENTALS

125

Greenheck rep Directory


Greenheck Sales office representatives
aLaBaMa *Birmingham - air-tech incorporated *(Pensacola, FL) - air-tech of Pensacola *Mobile - air-tech of Pensacola aLaSka anchorage - Stinebaugh & Company arizOna *Phoenix - air Specialty Products tucson - air Specialty Products arkanSaS Little Rock - John Prince Company (Memphis, tn) - air Components inc. Springdale - John Prince Company CaLiFOrnia *anaheim - norman S. Wright/airelink Mech. equip. LLC Chico - norman S. Wright Mechanical equipment Fresno - norman S. Wright Mechanical equipment *Los angeles - norman S. Wright/airelink Mech. equip. LLC Pismo Beach - norman S. Wright Mechanical equipment *Sacramento - norman S. Wright Mechanical equipment *San Diego - Dave Dennison Co. inc. *San Francisco - norman S. Wright Mechanical equipment Santa Clara - norman S. Wright Mechanical equipment Santa rosa - norman S. Wright Mechanical equipment COLOraDO Colorado Springs - CFM Company *Denver - CFM Company Grand Junction - CFM Company Fort Collins - CFM Company COnneCtiCut *newington - Buckley associates inc. Stratford - Buckley associates inc. DeLaWare *(Phil, Pa) - Del-ren associates inc. Seaford - Ward-Boland associates inc. FLOriDa *Ft. Lauderdale/Miami - Cors-air Ft. Myers - Commercial air Management inc. Jacksonville - Stan Weaver & Company *orlando - Stan Weaver & Company *Pensacola - air-tech of Pensacola tallahassee - air-tech of Pensacola *tampa - Stan Weaver & Company West Palm Beach - Cors-air 205-942-7081 850-433-6443 850-433-6443 907-345-8021 480-377-9255 520-623-0656 501-666-5488 901-382-1884 479-756-5240 714-632-9800 530-345-9289 559-271-3200 818-367-6100 805-773-2810 916-381-6666 619-440-5061 415-467-7600 408-748-1304 707-568-3903 719-528-1116 303-761-2291 970-243-4377 970-493-7293 860-666-0555 203-380-2405 856-541-1776 302-629-7006 954-456-4300 239-277-0029 904-695-9295 407-581-6940 850-433-6443 850-433-6443 800-783-6915 561-844-9767

126

REP DIRECTORY

* Denotes representatives who carry local inventory.

Greenheck Sales office representatives


GeOrGia albany - Mingledorffs inc. athens - Mingledorffs inc. *atlanta - Holden & associates Mingledorffs inc. augusta - Holden & associates Mingledorffs inc. Brunswick - Mingledorffs inc. Columbus - Mingledorffs inc. Conyers - Mingledorffs inc. Dalton - air alliance Forest Park - Mingledorffs inc. Gainesville - Mingledorffs inc. Lawrenceville - Mingledorffs inc. Macon - Mingledorffs inc. Marietta - Mingledorffs inc. *norcross - Mingledorffs inc. Savannah - Mingledorffs inc. Statesboro - Mingledorffs inc. Valdosta - Mingledorffs inc. Warner robins - Mingledorffs inc. HaWaii *Honolulu - norman S. Wright Mechanical equipment iDaHO Boise - technical air Products inc. (Spokane, Wa) - Parmely & associates inc. iLLinOiS *Chicago - Brucker Company (no. & Central illinois) - Brucker Company (So. illinois) - H.C. Sharp Company inc. inDiana (Cincinnati, oH) - eaP inc. evansville - rL Craig Company inc. Fort Wayne - Colby equipment Co. inc. Gary - Brucker Company *indianapolis - Colby equipment Co. inc. Jasper - RL Craig Company Inc. iOWa Davenport - Brucker Company Des Moines - Products inc. *(omaha, ne) - Commercial air Management (Sioux Falls, SD) - Climate Systems inc. kanSaS *Kansas City - Jorban-Riscoe Associates Inc. Wichita - Jorban-Riscoe Associates Inc. 913-438-1244 316-687-3277 309-691-5160 515-288-5738 402-339-9177 605-334-2164 229-432-5254 706-548-2563 770-458-4000 404-878-7755 706-854-0738 706-651-1950 912-265-5193 706-322-3870 770-918-9132 423-622-5525 404-361-2474 770-297-9335 678-442-1060 478-477-3193 770-426-0551 770-446-6311 912-236-8122 912-764-8841 229-245-8200 478-953-3727 808-678-3911 208-377-2071 509-443-1220 847-437-9690 309-691-5160 314-351-6900 513-489-9494 800-422-1935 260-482-3773 847-437-9690 317-545-4221 800-422-1935

* Denotes representatives who carry local inventory.

REP DIRECTORY

127

Greenheck Sales office representatives


kentuCkY (Cincinnati, oH) - eaP inc. (Huntington, WV) - Mason & Barry inc. Louisville - rL Craig Company inc. LOuiSiana Baton rouge - air-Side equipment inc. new orleans - air-Side equipment inc. Shreveport - reed Mechanical equipment inc. Maine *(Manchester, nH) - Buckley associates inc. Portland - Buckley associates MarYLanD Baltimore - Ward-Boland associates inc. Hagerstown - Ward-Boland associates inc. Salisbury - Ward-Boland associates inc. *Silver Spring - C.G. Wood Company inc. MaSSaCHuSettS *Boston - Buckley associates inc. *Pittsfield - Buckley associates inc. *Springfield- Buckley associates inc. MiCHiGan *Detroit - Michigan air Products escanaba - Vyron Corporation Grand rapids - Michigan air Products Saginaw - Michigan air Products MinneSOta *(Fargo, nD) - therm-air Sales Corporation *Minneapolis - TMS Johnson, Inc. (Sioux Falls, SD) - Climate Systems inc. MiSSiSSiPPi *Biloxi/Gulfport - Ward Mechanical equipment *Jackson - Ward Mechanical Equipment (Memphis, tn) - air Components inc. MiSSOuri *Kansas City - Jorban-Riscoe Associates Inc. (Memphis, tn) - air Components inc. Springfield - Jorban-Riscoe Associates Inc. St. Louis - H.C. Sharp Company inc. MOntana Great Falls - Sound air inc. neBraSka *omaha - Commercial air Management neVaDa Las Vegas - norman S. Wright Mechanical equipment reno - norman S. Wright Mechanical equipment
128
REP DIRECTORY

513-489-9494 304-755-0781 502-244-1600 225-275-6930 504-837-2346 318-687-8818 603-669-3566 207-773-0078 410-363-1833 301-791-0187 302-629-7006 240-241-5300 781-878-5000 518-438-7423 860-666-0555 248-837-7000 715-355-0200 616-534-8000 989-754-0409 701-282-9500 763-544-5442 605-334-2164 601-956-3002 601-956-3002 901-382-1884 913-438-1244 901-382-1884 913-438-1244 314-351-6900 406-727-8483 402-339-9177 702-361-4212 775-826-8622

* Denotes representatives who carry local inventory.

Greenheck Sales office representatives


neW HaMPSHire *Manchester - Buckley associates inc. neW JerSeY *edison - aDe Systems *(Philadelphia, Pa) - Del-ren associates inc. neW MeXiCO *albuquerque - Mechanical representatives inc. neW YOrk *albany - Buckley associates inc. *Buffalo - H & V Commercial ind Sales inc. *new york - aDe Systems rochester - t.H. Herman inc. Syracuse - George race & associates inc. nOrtH CarOLina asheville - Hoffman & Hoffman inc. Charlotte - Hoffman & Hoffman inc. *Greensboro - Hoffman & Hoffman inc. raleigh - Hoffman & Hoffman inc. Wilmington - Hoffman & Hoffman inc. nOrtH DakOta *Fargo - therm-air Sales Corporation OHiO Cincinnati - eaP inc. *Cleveland - air Control Products inc. Columbus - air Systems Diversified inc. Dayton - eaP inc. (Huntington, WV) - Mason & Barry inc. toledo - air Control Products inc. OkLaHOMa oklahoma City - engineered equipment tulsa - engineered equipment. OreGOn (Boise, iD) - technical air *Medford - Johnson Air Products *Portland - Johnson Air Products PennSYLVania *Harrisburg - H & H Sales associates inc. *Philadelphia - Del-ren associates inc. Pittsburgh - Pittsburgh air Systems inc. Scranton - Colman Sales Co. inc. rHODe iSLanD *(Boston, Ma) - Buckley associates inc. 781-878-5000 717-796-2401 856-541-1776 412-741-3070 570-587-1188 208-377-2071 541-772-2690 503-234-5071 405-525-7722 918-624-1005 513-489-9494 440-526-3020 614-291-0960 513-489-9494 304-755-0781 419-380-8990 701-282-9500 828-296-0111 704-364-4700 336-292-8777 919-781-8011 910-791-4775 518-438-7423 716-897-5010 516-256-4800 585-394-8386 315-455-4901 505-821-2563 732-553-0038 856-541-1776 603-669-3566

* Denotes representatives who carry local inventory.

REP DIRECTORY

129

Greenheck Sales office representatives


SOutH CarOLina Columbia - Hoffman & Hoffman inc. Greenville - Hoffman & Hoffman inc. Charleston - Hoffman & Hoffman inc. (Charlotte, nC) - Hoffman & Hoffman inc. SOutH DakOta Sioux Falls - Climate Systems, inc. tenneSSee Blountville - air alliance Chattanooga - air alliance Knoxville - air alliance Memphis - air Components inc. nashville - Underwood air Systems inc. teXaS *austin - Mechanical reps inc. *Dallas - Bartos industries el Paso - Mechanical representatives inc. *Fort Worth - Bartos industries *Houston - H.D. Grant Company inc. *Lubbock - David G. Halley & Co. inc. *San antonio - Mechanical reps inc. utaH *Salt Lake City - Mechanical Products intermountain VerMOnt *(albany, ny) - Buckley associates inc. VirGinia Chesapeake - Hoffman & Hoffman inc. richmond - Hoffman & Hoffman inc. roanoke - Hoffman & Hoffman inc. (Salisbury, MD) - Ward-Boland associates inc. *(Silver Spring, MD) C.G. Wood Company inc. WaSHinGtOn *Seattle - Dorse & Company inc. Spokane - Parmely & associates inc. Vancouver - Johnson Air Products WaSHinGtOn, D.C. *(Silver Spring, MD) - C.G. Wood Company inc. 240-241-5300 206-284-2610 509-443-1220 503-234-5071 757-548-1700 804-272-1500 540-725-8701 302-629-7006 240-241-5300 518-438-7423 801-352-9003 512-444-1835 214-350-6871 915-779-1212 817-332-7906 713-668-8880 716-897-5010 210-650-9005 423-279-7117 423-622-5525 865-450-9770 901-382-1884 615-251-4555 605-334-2164 803-765-9360 864-676-1888 843-884-3201 704-364-4700

130

REP DIRECTORY

* Denotes representatives who carry local inventory.

Greenheck Sales office representatives


WeSt VirGinia Charleston - Mason & Barry inc. Martinsburg - Ward-Boland associates inc. Morgantown - Pittsburgh air Systems inc. WiSCOnSin Eau Claire - TMS Johnson Inc. Green Bay - Vyron Corporation Madison - Vyron Corporation Milwaukee - Vyron Corporation *Schofield - Vyron Corporation WYOMinG (Great Falls, Mt) - Sound air inc. (Ft. Collins, Co) - CFM Company 406-727-8483 970-493-7293 763-544-5442 920-405-8822 608-850-3400 262-783-3600 715-355-0200 304-755-0781 301-791-0187 412-539-1234

Greenheck Sales office representatives


CanaDa *eH Price Limited *Calgary *Charlesbourg *Dartmouth *edmonton *Hamilton *Kelowna *London *Montreal *ottawa *regina *Saskatoon *toronto *Vancouver *Vancouver island *Winnipeg Global Mechanical Systems Ltd. *new Brunswick & Prince edward island 506-857-4887 403-777-2790 418-849-2306 902-468-1310 780-477-9231 905-383-3599 250-765-7226 519-451-5100 514-334-9804 613-725-2029 306-525-2367 306-931-3316 905-660-0066 604-777-1712 250-475-2500 204-982-2222

* Denotes representatives who carry local inventory.

REP DIRECTORY

131

international agents
arGentina air-technik S.r.L. d/b/a Cermac auStraLia imagro australia Pty Ltd BaHaMaS Cors-air Bahamas BaHrain awal Products Co. W.L.L. Brunei Benaire engineering Pte, Ltd *CariBBean iSLanDS SaeG engineering Group CHiLe roster Ltda uMWelt technik Servicios de ingenieria Ltda CHina BeiJinG Hongen times of Prosperity Science and technology (Beijing) Co Ltd CHenGDu CentraL WeSt Sichuan Xiongfeng engineering equipment Co. Ltd. GuanGzHOu Guangzhou Hongxin Co. Ltd. qinGDaO Qingdao Glare Mechanical & Electrical SHanGHai CitY techair Shanghai enterprise Co. Ltd. tianJin tianjin Zhengli Machine and equipment Sales Co Ltd. COLOMBia SaeG engineering Group COSta riCa Strong intl Central america DOMiniCan rePuBLiC SaeG engineering Group eCuaDOr SaeG engineering Group eGYPt Contact eL SaLVaDOr Strong intl Central america GuaM norman S. Wright 671-475-3911 50322298939 2027941517 305-718-8146 809-473-7234 5062341640 5716131749 86-22-2373-5760 86-21-5293-0291 86-532-8576-9200 86-20-3890-3603 86-28-8737-4378 86-10-6484-5471 5623651876 115625730504 305-718-8146 6567410280 973-17813535 954-456-4300 61-892863220 541142923453

132

REP DIRECTORY

* Denotes representatives who carry local inventory.

international agents
GuateMaLa Strong intl Central america HOnDuraS Strong intl Central america HOnG kOnG Kwan yick engineering Company. inDia Bojoy Contract engineers Private Limited WeSt & SOutH Chatur Parmanand Vaswani nOrtH & eaSt rohan engineers inc. inDOneSia Pt Multi Sindomulya iSraeL M.n. engineering Co. JaPan ninon enterprises Ltd. JOrDan Sources for engineering Supplies Co. Ltd. kOrea aCeair Corporation kuWait Gulf Facilities General trading LeBanOn air Distribution Center S.a.r.L. MeXiCO CanCun Versa rep. S.a. de C.V. CHiHauHau Mechanical representatives COaHuiLa aguasistemas intergrales S.a. de C.V. GuaDaLaJara Proveedora industrial Panamericana S.a. de MeXiCO CitY Versa Comercializadora S.A. de C.V. MOnterreY Proveedora termica del norte S.a. de C.V. tiJuana Becerril OMan Khimji ramdas - a/C Division 968-24852700 526646821523 528181257300 525556041377 52338259325 11526865567423 915-779-1212 529988432574 961-135-3823 965-2575-7630 822-598-2793 96265525255 81-98-936-6099 97239799833 622163858377 911246455667 912-222844303 911126675767 852-2411-0289 5045504888 50224850434

* Denotes representatives who carry local inventory.

REP DIRECTORY

133

international agents
PakiStan Khan Brothers PanaMa SaeG Panama Peru SaeG Peru PHiLLiPPineS Fahrenheit industries inc. PuertO riCO technical Distributors inc. qatar Gulf Facilities trading Co. WLL SauDi araBia al Saadeh trading establishment SinGaPOre asiatic engineering Pte Ltd. insync HVaC Pte Ltd Bio-Pointe Pte. Ltd. Sri Lanka techno-Maart (Pte) Ltd. taiWan techair enterprise Co. Ltd. tHaiLanD Ventilation engineering Company Ltd. turkeY atC air trade Centre Ltd. Sti uniteD araB eMirateS DuBai Western technological equipment aBu DHaBi Faisal Jassim Trading Company LLC uruGuaY ing Schellemberg S.r.L. VenezueLa iMeX importacion y exportacion VietnaM asiatic engineering Pte Ltd. YeMen al-rashed trading Centre 967-1680770 84-8512-4436 582432327021 59822037200 97148105105 97142994124 902122834510 66253090602 886-2-2731-9100 94114717500 65-6291-8282 65-6665-6022 65-6748-8911 96614780643 9744501152 787-274-1818 63-2-374-3293 5112261600 5072606783 922-14526002

134

REP DIRECTORY

* Denotes representatives who carry local inventory.

W h e n Q u i c k e r i s B e t t e r - G re e n h e c k i s B e s t .
Greenhecks Quick Delivery Program provides many options to help you meet your projects schedule. Stocking warehouses and distribution centers around the world ensure same-day pickup and same-day shipment for orders in by 2 p.m. (CST). Hundreds of custom products can be manufactured through Quick Build in just days.
PICK UP OR WE SHIP. ALWAYS QUICK. LoaDinG aSSiStanCe.

anywhere. anytime.
U.S. CaLiFornia FLoriDa NEW JERSEY nortH CaroLina teXaS WiSConSin

Regional warehouses are nearby and fully stocked


1 HoUr
LoCaL StoCK CUStoMer PiCK UP

QD STOCK
SaMe-Day or neXt Day SHiPMentS

1-Day WorLDWiDe MeXiCo ManUFaCtUrinG LoCationS CaLiFornia KentUCKy nortH CaroLina WiSConSin CHina
CUStoM-BUiLt ProDUCtS SHiPPeD in one Day

3-5-10-Day
CUStoM-BUiLt ProDUCtS SHiPPeD in 3, 5 or 10 DayS

StanDarD LeaD tiMe


aLL GreenHeCK ProDUCtS are SHiPPeD aS FaSt aS PoSSiBLe FroM one oF oUr FoUr ManUFaCtUrinG PLantS.

P.O. Box 410 Schofield, WI 54476-0410

PrSrt StD US Postage PaiD Wausau Wi Permit no 1300

WorLDWiDe LeaDer in air MoVeMent & ControL

www.greenheck.com
Change of address?
Please help us keep our mailing list up to date. if you have any changes, additions or deletions, please note them near your address and fax this page to 715.355.2399. thanks for your help.

Building value in air


Greenheck delivers value to mechanical engineers by helping them solve virtually any air quality challenges their clients face with a comprehensive selection of top quality, innovative air-related equipment. We offer extra value to contractors by providing easy-to-install, competitively priced, reliable products that arrive on time. And building owners and occupants value the energy efficiency, low maintenance and quiet dependable operation they experience long after the construction project ends.

our Warranty
Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the shipment date. Any units or parts which prove defective during the warranty period will be replaced at our option when returned to our factory, transportation prepaid. Motors are warranted by the motor manufacturer for a period of one year. Should motors furnished by Greenheck prove defective during this period, they should be returned to the nearest authorized motor service station. Greenheck will not be responsible for any removal or installation costs. as a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice.

P.O. Box 410 Schofield, WI 54476-0410 Phone (715) 359-6171 greenheck.com

QD Volume 23 June 2009 R Copyright 2009 Greenheck Fan Corp.