Anda di halaman 1dari 42

SIMATIC HMI WinCC V6.

2 SP2 Installation Notes

1 Installation Guide ______________ 2 Scope of Delivery ______________ 3 Licenses and Licensing ______________ 4 Installation Requirements ______________ 5 Installing WinCC ______________ 6 Perform uninstall ______________ 7 Upgrading WinCC ______________ 8 ______________
Notes about Running the Software

SIMATIC HMI WinCC V6.2 SP2 Installation Notes


Software Installation Manual

Printout of the Online Help

09/2007

Printout of the Online Help

Safety Guidelines

Safety Guidelines

This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account.

If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage.

Qualified Personnel
The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards.

Prescribed Usage
Note the following: WARNING This device may only be used for the applications described in the catalog or the technical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens. Correct, reliable operation of the product requires proper transport, storage, positioning and assembly as well as careful operation and maintenance.

Trademarks
All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner.

Disclaimer of Liability
We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions.

Siemens AG Automation and Drives Postfach 48 48 90327 NRNBERG GERMANY

Ordernumber: Printout of the Online Help 09/2007

Copyright Siemens AG 2007. Technical data subject to change

Table of contents
1 2 3 4 Installation Guide ....................................................................................................................................... 5 Scope of Delivery....................................................................................................................................... 7 Licenses and Licensing ............................................................................................................................. 9 Installation Requirements ........................................................................................................................ 11 4.1 4.2 4.3 4.4 4.5 4.5.1 4.5.2 4.5.3 4.5.4 4.5.5 4.6 5 5.1 5.2 5.3 5.4 5.5 6 7 6.1 7.1 7.2 7.3 8 WinCC Installation Requirements ................................................................................................11 Hardware Requirements for the Installation ................................................................................12 Software Requirements for the Installation..................................................................................14 Notes on Data and System Security............................................................................................17 Access Rights in Operating System ............................................................................................18 Defining Access Rights in the Operating System ........................................................................18 Including users in the "SIMATIC HMI" user group.......................................................................19 Include user in the user group "SQLServer2005MSSQLUser$<COMPUTERNAME>$WINCC".................................................19 Including domain-global user group in the "SIMATIC HMI" user group.......................................20 Release existing project for "SIMATIC HMI" user group .............................................................20 How to Adapt the Windows Security Policies ..............................................................................21 Installing WinCC ..........................................................................................................................23 How to Install MS Message Queuing...........................................................................................24 How to Install Microsoft SQL Server 2005...................................................................................27 How to Install WinCC ...................................................................................................................28 How to Install Supplementary Components Later .......................................................................30 How to Perform an Uninstall ........................................................................................................31 Upgrading WinCC ........................................................................................................................33 Information on Migrating Projects ................................................................................................34 How to Perform an Upgrade Installation......................................................................................36

Installing WinCC ...................................................................................................................................... 23

Perform uninstall...................................................................................................................................... 31 Upgrading WinCC.................................................................................................................................... 33

Notes about Running the Software .......................................................................................................... 39 Index........................................................................................................................................................ 41

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Table of contents

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installation Guide
Contents

This documentation contains important information on the scope of delivery, as well as on the installation and operation of WinCC. The information contained here takes precedence over the information contained in the manual and online help.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installation Guide

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Scope of Delivery
Delivered Components
WinCC V6.2 SP2 is available as a basic package and as an upgrade package. You will receive the following components:
Component DVD WinCC V6.2 SP2 Standard Package X

SQL Server 2005 Service Pack 1 for WinCC V6.2 X DVD DVD "MS ServicePacks & Tools": - Microsoft Internet Explorer 6 SP1 - Windows 2000 Service Pack 4 - Windows XP Service Pack 2 - Windows Server 2003 Service Pack 2 - Hotfix - Windows Server 2003 - Hotfix - Windows XP SP2 - Security Patch - Win2000 - MUI Patch - Windows Server 2003 SP2 - Hotfix - Microsoft SQL Server 2005 SP1 - Microsoft .Net Framework V1.1 CD SIMATIC NET 1) Storage medium with required licenses Certificate of License Installation Notes in short version (from this document) 3)
2)

X X X X

1) Please note the software requirements of the supplied SIMATIC NET version. Not all drivers are supported by Windows XP. 2)

WinCC V6.2 SP2, the License Keys for new deliveries of WinCC are shipped on USB stick and are no longer issued on the previously used license disk.

You can find detailed installation notes in the "Read first" file on your "WinCC V6.2 SP2" DVD:
3)

Double click in the WinCC Information System summary on the entry "Installation Notes". Choose any subject via . A gray menu bar will appear on the upper edge of the displayed page. Open the printable version using the entry "Tools" > "Open PDF". To do this, you will need Adobe Acrobat Reader V5.0. Adobe Acrobat Reader is available free of charge at this URL http://www.adobe.com/products/acrobat Additional PDF files for printing the online help are available in the "PrintDocuments" folder on your "WinCC V6.2 SP2" DVD.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Scope of Delivery

Communication driver
The following table lists the communication drivers included in the package. Additional required licenses are contained in their respective option packages.
Communication driver OPC PROFIBUS DP PROFIBUS FMS SIMATIC 505 TCPIP SIMATIC S5 Ethernet Layer 4 SIMATIC S5 Ethernet TF 1) SIMATIC S5 Profibus FDL SIMATIC S5 Programmers Port AS511 SIMATIC S5 Serial 3964R SIMATIC S7 Protocol Suite SIMATIC TI Ethernet Layer 4 SIMATIC TI Serial System Info Windows DDE
1) 2)

requires additional license No No No 2) No 2) No 2) No 2) No No No No No 2) No No No

Communication driver is only supported on stand-alone systems under Windows 2000. The storage medium contains the WinCC licenses.

The WinCC DVD Start Program


To open the WinCC DVD Start page, place the DVD in the drive. If the operating system's autorun function is activated, the DVD will start automatically. If the autorun function is disabled, start the 'Start.exe' program on the DVD. The Start page on the WinCC DVD will open. Under "Welcome", you will find a video with information about the software. The WinCC Information System with information about the system and installation is available under "Read First". "Display DVD Contents" opens Windows Explorer. "Install SIMATIC WinCC" starts the WinCC setup program to install WinCC. See "Additional Software" for setup programs for installing other applications and additional software to WinCC. With "Language selection", you can select the language for the Start page and the setup program. With "Exit", you can close the Start page of the WinCC DVD.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Licenses and Licensing


Introduction

The WinCC software is protected and can only be used in its full measure with a valid license. Each installed software and option used requires a valid license for unrestricted operation of WinCC. You will receive a storage medium with all necessary license keys for the installation of licenses. The licenses for optional packages must be ordered separately. Licenses which are installed for use in WinCC are transferred from the storage medium to a local drive and are unregistered on the storage medium. The cumulation of more than one license per component subject to a license is possible only for archive licenses. Other licenses cannot be cumulated. Note Furthermore, the licensee confirms that the software (SW) contains licensed software by Microsoft Corporation or its subsidiaries. Thereby, licensee agrees to be bound by the terms and conditions of the appended license agreement between Microsoft SQL Server and end user, and to fulfill same.

Notes On License Conditions


Please observe the enclosed license conditions, which are also displayed during the installation. The SIMATIC WinCC software is copy-protected against unlicensed use. Additional information on licenses and license types may be found under "Getting Started > Licensing" in the WinCC Information System. Installed licenses are required to enable proper operation of WinCC. If WinCC is installed without licenses, the program will switch to demo mode at start-up. Note It is not allowed to run WinCC in process mode without a valid license.

Upgrade to WinCC V6
Following an upgrade of WinCC V5 to WinCC V6, only the V6 license is available. This license is not recognized by WinCC V5. If WinCC V5 is used as an alternative to WinCC V6, the user is authorized to create an image of WinCC V5, including its license. However, both WinCC versions may only be used as an alternative to each other. Any concurrent use of WinCC V6 and WinCC V5 represents a violation of the license agreement.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Licenses and Licensing

Demo Mode
If a license is missing for one or several components, WinCC will run in demo mode. WinCC also switches to demo mode when the maximum authorized number of process tags or archive tags is exceeded in a project. In Demo mode, you can use the WinCC software fully for a maximum of one hour. After this period, the operation of WinCC violates the license agreements. After one hour, the WinCC Explorer and the editors will be closed. In Runtime, the system will request the acquisition of a valid license. This dialog will appear every 10 minutes. Details on demo mode may be found in WinCC Information System under "Getting Started > Licensing".

Microsoft SQL Server 2005


A license is necessary to use the Microsoft SQL Server 2005 database. This license is readily available in a licensed and proper installation of WinCC. The licensed SQL server installed with WinCC may only be used in connection with WinCC. Its use for external applications or an internal database requires an additional license.

Installation of Licenses
Licenses may be installed during installation of WinCC or after the fact. Connect the storage medium containing the WinCC licenses with your computer after the setup program prompts you to install the licenses. All required licenses are automatically installed. For installation of licenses after the fact, you may use the Automation License Manager. You will find the Automation License Manager in the Windows start menu in the "SIMATIC" program group. An after-the-fact installation of a license will take effect upon restart of WinCC. For the installation of licenses, the following requirements must be met: Administrator rights are required. The storage medium containing the licenses must not be write protected. For configuration purposes, RC licenses may be installed on a local drive but can also be installed on a license server. Licenses may only be installed on a non-compressed drive. Note After uninstalling WinCC, the licenses remain installed on the system.

Upgrade Installation
You must upgrade the existing authorizations if you have received WinCC as upgrade from V5.x to V6.2. The same is applicable to authorizations of communication drivers and WinCC options. The WinCC V5 licenses can then no longer be used after the upgrades. In order to use the WinCC Web Navigator under WinCC V6.2 you need Version 6.2 of the Web Navigator. Authorizations up to V6.1 used for the Web Navigator up until now can no longer be used. A corresponding upgrade is required.
Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

10

Installation Requirements
4.1 WinCC Installation Requirements

4.1

Introduction
You will need special hardware and software for the installation of WinCC. The requirements are described in the chapters "Hardware Requirements for Installation" and "Software Requirements for Installation". The first check if certain conditions are met is already executed during the installation of WinCC. The following conditions are checked: Operating system User Rights Graphic Resolution Internet Explorer MS Message Queuing SQL Server Due Complete Restart (Cold Restart)

Error Messages
If one these conditions is not met, the WinCC installation will be aborted and an error message will be displayed. For details about the error messages displayed see the table below.
Error Message To execute installation properly, restart the computer Required operating system, Win XP / Win 2000 SP4 This application requires VGA or any higher resolution You do not have administrator rights. Log on as administrator. Explanation The software installed on your computer requires a restart. Before WinCC can be installed, the computer should be restarted once. Upgrade the operating system to at least Windows XP SP2 and Windows 2000 SP4, respectively. Check the settings of the connected monitor and upgrade the graphic card, if necessary. Administrator rights are required for the installation. Please log in to Windows again as a user with administrator rights.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

11

Installation Requirements 4.2 Hardware Requirements for the Installation


Error Message The WinCC instance of Microsoft SQL Server 2005 SP1 Hotfix was not found. Explanation Install Microsoft SQL Server 2005 SP1 Hotfix from the DVD included in the delivery. This message may also indicate that you are lacking administrator rights for this installation. In this case, log on to Windows again as user with administrator rights. Setup has detected that unInstallShield is active. Please close unInstallShield and restart Setup. The Microsoft message queuing services are not installed Close unInstallShield. This message may also indicate that you are lacking administrator rights for this installation. In this case, log on to Windows again as user with administrator rights. Install the Microsoft message queuing services. To do this, you will need the Windows installation CD. Instructions are included in Chapter "Installing MS Message Queuing".

The required SQL Server 2005 SP1 entity is not Install Microsoft SQL Server 2005 SP1 Hotfix from the DVD included in installed. the delivery. Instructions are included in Chapter "Installing Microsoft SQL Server 2005".

4.2

4.2

Hardware Requirements for the Installation

Introduction
Certain hardware configuration conditions must be fulfilled for installation.

Hardware Requirements
WinCC supports all common IBM/AT-compatible PC platforms. To efficiently work with WinCC, select a system with the recommended specifications. Note Server requirements are also valid for single-user systems unless specified otherwise.

Minimum CPU Client: Intel Pentium III, 600 MHz Server: Intel Pentium III; 1 GHz Central archive server: Intel Pentium 4; 2 GHz Working memory Client: 512 MB Single-user system: 512 MB / Server: 1 GB Central archive server: 1 GB

Recommended Client: Intel Pentium III; 1 GHz Server: Intel Pentium 4; 2 GHz Central archive server: Intel Pentium 4; 2.5 GHz Client: 512 MB Single-user system: 1 GB / Server: >1 GB Central archive server: >= 2 GB

12

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installation Requirements 4.2 Hardware Requirements for the Installation


Minimum Free memory on hard disk - for the installation of WinCC 1) - for working with WinCC 2) 3) Virtual memory 4) Working memory for Windows printer spooler 5) Graphic card Number of colors Resolution Client: 500 MB / Server: 700 MB Client: 1 GB / Server: 1.5 GB / central archive server: 40 GB 1.5 X working memory 100 MB Recommended Client: 700 MB / Server: 1 GB Client: 1.5 GB / Server: 10 GB / central archive server: 2 x 80 GB on different hard disks. 1.5 X working memory > 100 MB

16 MB 256 800 * 600

32 MB True Color 1024 * 768

1) The installation requires at least 100 MB of free memory space for additional system files on the drive on which the operating system is installed. Generally the operating system is drive "C:". 2)

Depending on project size as well as size of archives and packages. On project activating, free memory space of at least 100 MB must be available. WinCC projects should not be stored on compressed drives or directories. Use the recommended value in the area "Total size of swap file for all drives" for "Size of swap file for a specific drive". Enter the recommended value in both the "Start size" field as well as in the "Maximum size" field.

3) 4)

WinCC requires the Windows printer spooler to detect printer faults. Therefore, no other printer spooler may be installed.
5)

Note In the case of online configuration, the recommended requirements are valid as the minimum requirement.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

13

Installation Requirements 4.3 Software Requirements for the Installation

4.3

4.3

Software Requirements for the Installation

Introduction
For the installation, certain requirements concerning operating system and software configuration must be met. NOTICE WinCC is basically approved for operation in a domain or work group. However, observe the domain-group policies and domain restrictions which could hinder the installation. In this case, remove the computer from the domain before installing Microsoft Message Queuing, Microsoft SQL Server 2005 and WinCC. Log on to the computer concerned locally with administrator rights. Carry out the installation. Following successful installation, the WinCC computer can be registered in the domain again. If the domain-group policies and domain restrictions do not impair the installation, the computer must not be removed from the domain during installation. However, please note that the domain-group policies and domain restrictions could affect operation. If these restrictions cannot be overcome, operate the WinCC computer in a work group. If necessary, contact the domain administrator.

Operating system
WinCC is only released for the operating languages German, English, French, Italian and Spanish or multilingual operating systems. The Asian version of WinCC has been released for multilingual operating systems and for operating languages of English, simplified Chinese (PR China), traditional Chinese (Taiwan), Japanese, and Korean. All servers should be operated using Windows Server 2003 Standard and Enterprise Edition. All clients in a projects must be operated using either Windows XP Professional or Windows 2000 Professional. The use of either Windows Server 2003 or Windows XP Professional results in respective restrictions which should be taken into account when selecting the operating system: The SIMATIC Ethernet TF driver is only supported by Windows 2000.

Single-user Systems and Clients


WinCC runs under Windows XP Professional and Windows 2000.
Operating system Windows XP Configuration Windows XP Professional Service Pack 2 Comments Please note the software pre-requisites of the delivered SIMATIC NET-Version. While installing Windows XP Internet Explorer V6.0 Service Pack 1 is installed automatically. Windows 2000 Windows 2000 Professional Service Pack 4 ---

14

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installation Requirements 4.3 Software Requirements for the Installation


Single user systems and clients in WinCC multi-user systems can also be operated on Windows servers 2003. While installing WinCC, the following components will be installed after confirmation: Microsoft Security Patch MS04-12 (for Windows 2000 Professional SP4, corresponds to Microsoft Security Patch KB828741) Microsoft Security Patch KB319740 (for Windows XP SP2) Microsoft Security Patch KB929046 (for Windows Server 2003 SP2 and Windows Server 2003 R2)

WinCC server
A WinCC server can only be operated on Windows Server 2003 Standard and Enterprise Edition or Windows Server 2003 R2.
Operating system Windows Server 2003 Windows Server 2003 R2 Configuration Server 2003 Service Pack 2 Server 2003 Service Pack 2 Comments The MUI version of Windows Server 2003 SP2 and Windows Server 2003 R2 SP2 additionally require the Microsoft MUI patch KB925148. The patch is available on the "MS Service Packs & Tools" DVD.

Note WinCC is not suitable for use in a Microsoft terminal server. You can use the Microsoft terminal server only in connection with the WinCC Web client. Please observe the information in the WinCC Web Navigator installation instructions.

Settings for Windows Server 2003


When configuring the system, the following settings must be adapted in the Control Panel: Windows Server 2003: Activate "Network and DF connections" > Connection "internal" or LAN connection > "Status" > "Properties" > "Activate file and printer release for Microsoft networks > "Properties" > "Maximize data throughput for network applications" Windows Server 2003: Activate "System properties" > "Extended" > "System performance" > "Settings" > "Expanded" > "Processor time scheduling" > "Background services" In the event of problems with the connection between a Client and the Server, check the settings for the client licensing mode on the server. If your network only has one server, you must select the setting "Per Server". The "Number of concurrent connections" must equal the number of clients. If your network has multiple servers, you must select the setting "Per Seat". For further information about licensing, please see the operating system's documentation.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

15

Installation Requirements 4.3 Software Requirements for the Installation

Microsoft Message Queuing Services


WinCC requires Microsoft Message Queuing Services. Detailed information can be found in the chapter "Installing Microsoft Message Queuing".

Microsoft SQL Server 2005


WinCC requires Microsoft SQL Server 2005 SP1 Hotfix. The corresponding access rights must have been set up for accessing the SQL server data. Detailed information can be found in the chapter "Installing Microsoft SQL Server 2005".

Operation with Several Network Cards


When a server is used with several network cards, please observe the notes in Chapter "Special Features of Communication Using a Server with Several Network Cards".

Process Communication Driver


Use the supplied SIMATIC NET CD supplied for the SIMATIC NET driver.

Internet Explorer - Requirements


WinCC requires Microsoft Internet Explorer V6.0 SP1 or SP2. Microsoft Internet Explorer V7.0 is also released for WinCC. However, WinCC does not support the "Tabbed Browsing" functionality of the browser. Internet Explorer V6.0 SP1 can be installed from the supplied "MS Service Packs & Tools" DVD. Please select from the following options for Internet Explorer: Installation options: Standard installation Updating the Windows Desktop: No Active Channel Selection: None If you wish to fully use WinCC's HTML Help, you must permit the use of JavaScript under "Internet Options" in Internet Explorer.

Adapting Security Policies


The operating system must permit the installation of unsigned drivers and files. Detailed information is available in the Chapter "Adapting Security Policies under Windows".

16

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installation Requirements 4.4 Notes on Data and System Security

4.4

4.4

Notes on Data and System Security

Introduction
System security when using WinCC can be increased by implementing simple measures.

Preventing Access to the Operating System Layer in Runtime


If the Windows Selection dialog is opened in an activated WinCC project, access to the Windows operating system is possible using this function. A Windows Selection dialog is opened, for example, when data is imported or files are selected. Protect the corresponding function by executing a Permission Check via the User Administrator to prevent unauthorized access to the operating system.

Preventing access to the Windows toolbar


Use the computer properties to prevent the Windows toolbar being displayed in runtime. Open the "Computer properties" dialog and deactivate all the hotkeys on the Parameter tab control in the "Disable Keys" section. In addition, deactivate the "Keep the taskbar on top of other windows" setting in Windows.

Disable Keys
If the key combination is disabled, the following key combinations are also disabled in runtime:
Key combination <Windows key+U> Press <Shift> five times Press <Shift right> for eight seconds <Alt left+Shift left+Num> <Alt left+Shift left+Print> Function System utility program manager Locking function Impact delay Keyboard mouse High contrast

NOTICE The functions can be configured using the Windows Control Panel. If the functions are activated in the Windows Control Panel before activating WinCC Runtime, they are no longer locked in runtime.

Local user rights when operating WinCC


Local administrator rights are required to install WinCC. Local power user rights for Windows are required in order to operate WinCC.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

17

Installation Requirements 4.5 Access Rights in Operating System


Local power user rights for Windows are required on the client as well as the server Windows for remote access to a WinCC project. In order to operate a WinCC Client in runtime, the "User" user right is the minimum requirement. Prior to operation, however, the administrative settings must have been set up by an administrator or power user, e.g. the authorization of file rights or printer driver settings.

4.5

4.5

Access Rights in Operating System

4.5.1

Defining Access Rights in the Operating System

Introduction
When working with WinCC, certain folders can be enabled for access via the network. For reasons of security, this folder should only be made available to specific users.

Access rights specified in WinCC


Following WinCC installation, WinCC automatically establishes the following local groups in Windows User and Group Administration: "SIMATIC HMI". These members may create local projects, and may process, start, and access these projects remotely. By default, the user who executes the WinCC installation, and the local administrator are included in this group. Additional members must be added manually by an administrator. "SIMATIC HMI CS". These members may configure only but may not make any changes to runtime components directly. By default, this group is empty and reserved for later use. "SIMATIC HMI Viewer". These members have read access only to configuration and runtime data. This group is primarily used for accounts for web publication services, e.g., IIS (Internet Information Services) for operation of WinCC Webnavigator. After installation, the directory "InstallationDirectory/WinCC/aplib" with the name "SCRIPTFCT" is unlocked for user group "SIMATIC HMI". This directory contains central libraries for project script functions. If a project is newly created locally, the members of user groups "SIMATIC HMI" and "SIMATIC HMI CS" receive access rights to the project directories. Following a manual copy, the administrator or main user may have to open the project once to set the local authorizations properly. Thereafter, settings for the unlocked directory are not changed any further by WinCC. You may manually change settings, if necessary. Note Configurators and users of runtime components must be registered not only in a "SIMATIC HMI" group but also in a Windows group. Membership in the "SIMATIC HMI" group permits access to the projects only but no access to the operating system. In order to create a project, the configurator must be at least the main user and a member of the "SIMATIC HMI" group.

18

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installation Requirements 4.5 Access Rights in Operating System

Access rights defined by Microsoft SQL Server 2005


To access WinCC on Microsoft SQL Server 2005 members of the user group "SIMATIC HMI" need the corresponding user rights. For this, users must be included in the user group "SQLServer2005MSSQLUser$<COMPUTERNAME>$WINCC".

4.5.2

Including users in the "SIMATIC HMI" user group

Introduction
Include those local users in the "SIMATIC HMI" group whose login permits access to WinCC. You must first create local users to do so. Users of a domain may be directly included in the user group "SIMATIC HMI".

Procedure
1. Open the workstation administration under Windows. 2. Select the entry "Local Users and Groups > Users" in the navigation window . All local users are displayed in the data window. 3. Open the "New User" dialog via the context menu. Create a user account with the same login for each user who has to access WinCC. 4. Select the entry "Local Users and Groups > Groups" in the navigation window". All groups are displayed in the data window. Select the "SIMATIC HMI" group. 5. Using the pop-up menu, open the "Add Member" dialog and include those users as members of the "SIMATIC HMI" user group.

4.5.3

Include user in the user group "SQLServer2005MSSQLUser$<COMPUTERNAME>$WINCC".

Introduction
To access WinCC on Microsoft SQL Server 2005 members of the user group "SIMATIC HMI" need the corresponding user rights. For this, users must be included in the user group "SQLServer2005MSSQLUser$<COMPUTERNAME>$WINCC".

Prerequisite
The local users are created; their login is used to access WinCC.

Procedure
1. Open the workstation administration under Windows. 2. Select the entry "Local Users and Groups > Users" in the navigation window . All local users are displayed in the data window.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

19

Installation Requirements 4.5 Access Rights in Operating System


3. In the navigation window, select the entry "Local Users and Groups > Groups". All groups are displayed in the data window. Select the "SQLServer2005MSSQLUser$<COMPUTERNAME>$WINCC" group. 4. Open the "Add member" dialog via the pop-up menu and also include members of the "SIMATIC HMI" as users of the "SQLServer2005MSSQLUser$<COMPUTERNAME>$WINCC" group.

4.5.4

Including domain-global user group in the "SIMATIC HMI" user group

Introduction
During operation of a domain, an additional domain-global user group may be created and included as a member of the "SIMATIC HMI" user group.

Requirements
The domain administrator creates a domain-global user group. Within the domain, the domain administrator includes those users in the domain whose login permits access to WinCC.

Procedure
1. Open the workstation administration under Windows. 2. In the navigation window, select the "Local Users and Groups > Users" entry. The data window displays all local users. 3. In the pop-up menu, select the "New User" dialog. Create an user account with the same login for the domain-global user group. 4. In the navigation window, select the "Local Users and Groups > Groups" entry. The data window displays all groups. Select the group "SIMATIC HMI". 5. Using the pop-up menu, open the "Add Member" dialog and include domain-global user group as members of the "SIMATIC HMI" user group.

4.5.5

Release existing project for "SIMATIC HMI" user group

Introduction
You must first remove the existing release of the project directory if the user group "SIMATIC HMI" has to access an existing user group. Then the project is released again while opening WinCC Explorer.

20

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installation Requirements 4.6 How to Adapt the Windows Security Policies

Procedure
1. Open the workstation administration under Windows. 2. In the navigation window, select the entry "Shared Folders > Shares". The data window displays all unlocked directories. 3. Select the respective project directory and remove the enable through the "Cancel Share" pop-up menu. 4. If you now open the project in WinCC, the project directory is automatically unlocked for the "SIMATIC HMI" user group, and all members of the user group are granted access to the project directory.

Note The enable name of the directory unlocked by WinCC must not be modified.

4.6

4.6

How to Adapt the Windows Security Policies

Introduction
Before you install WinCC, you must check the operating system settings. The system must permit the installation of unsigned drivers and files.

Procedure
1. In the Control Panel, open "Administrative Tools". 2. Double-click "Local Security Policy". 3. In the left pane, click "Local Policies". 4. In the right pane, double-click "Security Options". 5. Check the settings of the security policies below: Windows 2000: "Unsigned driver installation behavior" and "Unsigned files installation behavior (except drivers)" Windows XP / Windows Server 2003: "Devices: Unsigned driver installation behavior" For the policies, select either "Accept without warning" or "Warn, but permit installation".

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

21

Installation Requirements 4.6 How to Adapt the Windows Security Policies

22

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installing WinCC
5.1 Installing WinCC

5.1

Introduction
This chapter describes the installation of WinCC. MS Message Queuing and SQL Server 2005 entity "WinCC" must be installed prior to installing WinCC.

Installation of a WinCC file server


If a WinCC server is set up which is to be used for project data archiving only, only the WinCC file server needs to be installed. For more information see WinCC Information System in chapter "Configurations" > "File server". Note On one computer, WinCC V6 and the WinCC fileserver V6 cannot be installed at the same time.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

23

Installing WinCC 5.2 How to Install MS Message Queuing

5.2

5.2

How to Install MS Message Queuing

Introduction
WinCC implements the Message Queuing service from Microsoft. It is a component part of the operating system. MS Message Queuing is not a standard setting of the Windows installation and must be installed later, if necessary. The Windows installation CD is required to complete the installation. NOTICE WinCC is basically approved for operation in a domain or work group. However, observe the domain-group policies and domain restrictions which could hinder the installation. In this case, remove the computer from the domain before installing Microsoft Message Queuing, Microsoft SQL Server 2005 and WinCC. Log on to the computer concerned locally with administrator rights. Carry out the installation. Following successful installation, the WinCC computer can be registered in the domain again. If the domain-group policies and domain restrictions do not impair the installation, the computer must not be removed from the domain during installation. However, please note that the domain-group policies and domain restrictions could affect operation. If these restrictions cannot be overcome, operate the WinCC computer in a work group. If necessary, contact the domain administrator.

Procedure for Windows XP


1. Open the operating system Start menu and select "Settings" > "Control Panel" > "Add or Remove Programs". 2. Click the "Add or Remove Windows Components" button in the left-hand menu bar. The "Wizard for Windows components" will open.

24

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installing WinCC 5.2 How to Install MS Message Queuing

3. Select the "Message Queuing" component. The button "Details" will be activated. 4. Select the "Details" button. The dialog "Message Queuing" will open. 5. Activate the "Common" subcomponent. 6. Deselect all other subcomponents and acknowledge with "OK". 7. When the "Disk" dialog opens insert the requested Windows Installations CD-ROM. Select the "OK" button. MS Message Queuing will be installed. 8. Close the wizard using the "Finish" button.

Procedure for Windows 2000


1. Open the operating system Start menu and select "Settings" > "Control Panel" > "Add or Remove Programs". 2. Click the "Add or Remove Windows Components" button in the left-hand menu bar. The "Wizard for Windows components" will open.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

25

Installing WinCC 5.2 How to Install MS Message Queuing

3. Select the "Message Queuing" component and click the "Next" button. 4. Select the "Independent Client" MSMQ type. Click "Next". 5. Select the "Message Queuing Does Not Access the Active Directory" setting. Click "Next". 6. When the "Disk" dialog opens insert the requested Windows Installations CD-ROM. Select the "OK" button. MS Message Queuing will be installed. 7. Close the wizard using the "Finish" button.

Procedure for Windows Server 2003


1. Open the operating system Start menu and select "Settings" > "Control Panel" > "Add or Remove Programs". 2. Click the "Add or Remove Windows Components" button in the left-hand menu bar. The "Wizard for Windows components" will open. 3. Select the "Application Server" component and click "Next". The dialog "Application server" will open. 4. Select the "Message Queuing" component. The button "Details" will be activated. 5. Select the "Details" button. The dialog "Message Queuing" will open. 6. Activate the "Shared Components" subcomponent.

26

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installing WinCC 5.3 How to Install Microsoft SQL Server 2005


7. Deselect all other subcomponents and acknowledge with "OK". 8. When the "Disk" dialog opens insert the requested Windows Installations CD-ROM. Select the "OK" button. MS Message Queuing will be installed. 9. Close the wizard using the "Finish" button.

5.3

5.3

How to Install Microsoft SQL Server 2005

Introduction
This chapter describes how to install Microsoft SQL Server 2005 with Service Pack 1 Hotfix. For this, use the supplied DVD.

SQL server entity "WinCC"


During the installation, a new "WinCC" SQL server entity is created with Mirosoft SQL Server 2005, containing the required settings. This entity is always installed in English. The language in which other, existing SQL server entities have been installed has no influence. Existing entities are not affected by Service Pack.

Microsoft SQL Server 2005 Previously Installed


The Microsoft SQL Server entity for WinCC must also be installed even if another Microsoft SQL server entity is already installed.

Requirements
Administrator rights are necessary for the installation. There must be no SQL server entity with the name "WinCC", which was manually created, already installed.

Procedure
1. Start the "SQL Server 2005 Service Pack 1 Hotfix for WinCC V6.2" DVD. 2. Select the "Install SQL Server 2005" entry. Click the Next button in the "Welcome" dialog. 3. Please follow the licensing conditions in the "Software License Agreement" dialog. Click "Yes" to accept them. 4. Select the installation directory in the "Choose Destination Location" dialog. Click the "Browse..." button to change the suggested directory. Click "Next". The Add password for the sa login" is opened. 5. Choose the default password as a system administrator password for the SQL Servers or assign your own password. Your own password may be required for security reasons.
Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

27

Installing WinCC 5.4 How to Install WinCC


Only ASCII characters are accepted for the system administrator password. The password must at least contain 14 characters. Click "Next". The "Start Copying Files" shows the current settings. 6. Start the installation by clicking "Next". After the installation, the "Setup Complete" dialog is opened. Under Windows 2000, the installation may show an error message that the event display is fully written. Confirm with "OK" and continue the installation. 7. Close the dialog by clicking the "Finish" button.

"WinCC" entity after Deinstallation of WinCC


When uninstalling WinCC, the SQL Server entity "WinCC" remains installed and should be deinstalled for licensing reasons manually.

5.4

5.4

How to Install WinCC

Introduction
This chapter describes how to install and run WinCC.

Requirements
You need local administrator rights to install WinCC. The chapter "Instructions for Security of Data and System" contains information about user rights required to operate WinCC. The Windows component "MS Message Queuing" services must have been installed. The security policies must be adapted under Windows. Microsoft SQL Server 2005 SP1 Hotfix with a server entity "WinCC" must be installed. During installation you will need the license number which is located on the software product certificate. WinCC has only been released for operating system languages of German, English, French, Italian, and Spanish or multilingual operating systems. WinCC has been released as the Asian version for operating system languages of English, simplified Chinese (PR China), traditional Chinese (Taiwan), Japanese, and Korean, or multilingual operating system, respectively. Note If the WinCC Setup is started without having the administrator rights or if other installation prerequisites have not been fulfilled, an error message appears. For more detailed information on error messages see "Prerequisites for the installation of WinCC".

28

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Installing WinCC 5.4 How to Install WinCC

Scope of Installation
When installing WinCC, it is possible to select between minimum installation, typical installation and user-defined installation. The memory space required for each option, however, depends on the number of languages installed and is displayed in the Status Bar. Minimum installation (approx. 280 to 520 MB): Runtime CS SIMATIC communication driver OPC-Server Typical installation (approx. 320 to 620 MB): Minimum installation All the components that are already activated in the user-defined installation

Procedure
1. Start the WinCC product DVD. 2. Select "Install SIMATIC WinCC". 3. Follow the screen prompts. If you require additional languages other than English, please install the desired languages. 4. During installation, the security settings customized for WinCC are displayed in the "SIMATIC Security Control" dialog. The firewall is installed and configured automatically. Confirm the changes by clicking "Accept" and "Exit". 5. Restart the computer to conclude the installation.

Options
To set the scope of the WinCC installation, select user-defined installation. You can also install or uninstall components and languages at a later time. During the installation, you can view a brief description of the WinCC components by clicking on the respective component. The documentation for some of the options will be available only if the concerned option package is installed.

New Entries in the Windows Start Menu


After installing WinCC, you will find a new folder in the "SIMATIC" program group in the operating system's Start menu. From this folder, you may start WinCC Explorer ("SIMATIC" > "WinCC" > "WinCC V6.2 SP2") and may open various tools for working with WinCC ("SIMATIC" > "WinCC" > "Tools"). You will find the documentation for WinCC in the WinCC Information System. Retrieve the WinCC Information System under "SIMATIC" > "WinCC" > "WinCC Information System" in the same language in which you have installed WinCC. For documentation in other languages see "SIMATIC" > "Product Information". The Automation License Manager enables license management ("SIMATIC" > "License Management">"Automation License Manager").

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

29

Installing WinCC 5.5 How to Install Supplementary Components Later


You can view the customized security settings via SIMATIC Security Control ("SIMATIC > SimaticSecurityControl > SSC_Visual"). You may obtain a summary of the installed SIMATIC software and its components ("SIMATIC" > "Product Information" > "Installed Software").

5.5

5.5

How to Install Supplementary Components Later

Introduction
Once you have installed WinCC, you can later install additional languages or components.

Procedure
1. Open the operating system Start menu and select "Settings" > "Control Panel" > "Add or Remove Programs". 2. Select "SIMATIC WinCC V6.2 SP2" and click the "Change/Remove" button. The WinCC Setup program will open. 3. Select the individual components or languages that you want to install. The already installed components will be displayed. 4. Upon request, place the WinCC product DVD in the DVD drive. Once the start page of the DVD is opened via Autorun function, close the window with "Exit". 5. Follow the screen prompts.

Additional Software
Apart from the components offered during the user-defined installation of WinCC V6.2 SP2, you will find other optional software on the WinCC DVD. Select "Additional Software" on the start page of the WinCC DVD. The following software packages are offered: Configuration Tool WinCC Configuration Tool WinCC File Server Automation License Manager Global Script Example Project Installing the DXF Viewer Volo View Express 2.01 SQL Anywhere Studio 7 (shell setup only which requires inserting the WinCC V5.x CD)

See also
WinCC Installation Requirements (Page 11) How to Install WinCC (Page 28) How to Perform an Uninstall (Page 31) Licenses and Licensing (Page 9)
Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

30

Perform uninstall
6.1 How to Perform an Uninstall

6.1

Introduction
On your computer, you can uninstall WinCC completely or simply remove individual components, e.g. languages or components.

Procedure
1. Open the operating system Start menu and select "Settings" > "Control Panel" > "Add or Remove Programs". 2. Select"SIMATIC WinCC V6.2 SP2" and click the button "Change/Remove". The WinCC setup program will start. 3. Select whether you wish to remove WinCC completely or simply remove individual components, e.g. languages or components. If you wish to uninstall components, you must place the WinCC product DVD in the drive. The installed components will be displayed. 4. Follow the screen prompts.

Microsoft SQL Server 2005


Following the uninstall of WinCC, the "WinCC" SQL server entity must also be uninstalled. Select "Control Panel" > "Software" and then select the "Microsoft SQL Server 2005" item for uninstall. The use of the Microsoft SQL Server 2005 is only permitted when you have a valid license.

Automation License Manager / MS Update


When WinCC is removed, the following programs remain installed, as they may be needed by other SIMATIC products: Automation License Manager MS Update V1.0 SP1 If, after removing WinCC, you want to install an earlier version of WinCC, you will need to remove both of these programs. Open "Control Panel" > "Add/Remove Programs" and then select the corresponding item for removal.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

31

Perform uninstall 6.1 How to Perform an Uninstall

Changing the Settings in the Windows Event Viewer


When WinCC is installed, the WinCC Setup program changes the settings of the Event Viewer. Maximum Log Size (System Log/User Log): 1024 KB (default setting: 512 KB) Log Continuation (System Log/User Log): "Overwrite events" (default setting: Overwrite events that are older than 7 days) After uninstalling WinCC, these settings are not reset. You can adapt these settings in the Windows Event Viewer yourself. In the Start menu, select "Control Panel" > "Administrative Tools" > "Event Viewer". Rightclick in the left window pane on menus for "System" and "Application" (Windows XP), or "System Log" and "Application Log" (Windows 2000), respectively. Select "Properties" in the pop-up menu and restore the old settings.

32

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Upgrading WinCC
7.1 Upgrading WinCC

7.1

Introduction
You can upgrade to WinCC V6.2 via the upgrade installation for the following versions: WinCC V5.0 SP2 WinCC V5.1 WinCC V6.0.x Proceed as described in "Installation of WinCC" chapter. If you wish to migrate projects created with WinCC up to V5.1, please read the notes relating to project migration first. Note Restart the computer prior to commencing the update installation from WinCC V6.0.x to V6.2. If you execute an update from WinCC V6.0 or V6.0 SP1 to SP4, to WinCC V6.2 you should convert project pictures and libraries of your projects after the installation. Convert these configuration data using the Project Migrator. You may also covert pictures and libraries separately by using the pop-up menu of Graphics Designer in WinCC Explorer.

Database Sybase SQL Anywhere


Starting with V6.0, WinCC no longer administers Runtime data and configuration data using Sybase SQL Anywhere, but with Microsoft SQL Server 2000 or 2005. If you wish to use WinCC V6 on projects created using WinCC V5.0 SP2 and higher, you will require the Sybase SQL Anywhere 7 database for this migration. The use of the Sybase SQL Anywhere database requires a license. This license is present as long as you use WinCC V5.0 SP2 or V5.1. Sybase SQL Anywhere 7 is included in the scope of supply of WinCC V5.0 Service Pack 2 and WinCC V5.1. After uninstalling WinCC, the database remains on the computer. Sybase SQL Anywhere 7 may also be subsequently installed using the Autorun program on the WinCC V6 DVD. The installation CD for WinCC V5.0 Service Pack 2 or WinCC V5.1 is required for this.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

33

Upgrading WinCC 7.2 Information on Migrating Projects

7.2

7.2

Information on Migrating Projects

Introduction
If you upgrade a WinCC version beginning with V5.0 SP2 to WinCC V6.2, please take note of the following: CAUTION If you wish to work with a project in WinCC V6.2 which was created in WinCC V5.0 SP2 or WinCC V5.1, please read the Chapter "Migration" in the WinCC Information System prior to upgrading to WinCC V6.2.

Information on the System


Operating System: WinCC V6.2 will no longer run on Windows NT. For help on conversion to Windows 2000 or Windows XP, please contact the Microsoft Hotline. Multi-user system: Starting with WinCC V6.0, there is no differentiation anymore between clients and multiclients. The WinCC V6 client accesses one server or several servers according to the configuration.

Information on the Database System


Database system, Microsoft SQL Server 2005: In WinCC V5 the Sybase SQL Anywhere database system has been used. WinCC V6.2 manages Runtime data and configuration data using Microsoft SQL Server 2005. However, Sybase is still required to perform the migration. CAUTION Only uninstall Sybase after migrating the projects. Swapping data: WinCC enables you to swap your data directly via the new WinCC database. The Storage option is no longer necessary. As a result, the swapped-out data is available as a database. dBASE III: Direct access to the dBASE III databases is no longer possible. After migration of dBASE databases, the data is managed by the SQL Server 2005.

Notes on Licensing
Licensing of WinCC starting with version 6.0 differs from its predecessor versions. New RT or CS licenses are required. If more than 512 archive tags have been configured in a project, an additional license is required for archive tags.

34

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Upgrading WinCC 7.2 Information on Migrating Projects

Information on Migrating Projects


The differences between WinCC V5.0 SP2 or V5.1 and WinCC from V6.0 onwards result in the following restrictions that must be taken into account for the migration of a project: C functions and standard functions: Some C functions as well as the standard funtions TlgTableWindowPressInsertRecordButton and TlgTableWindowPressRemoveRecordButton will be obsolete. Detailed information can be found in the chapter "Changes with ODK". Adaptations in the project The project will have to be adapted following the migration process. This includes the conversion of screens and libraries, adaptation of the archiving and, if necessary, reconfiguring process tags. For more information about the migration of projects see chapter "Migration".

Information on Communication Drivers


Certain channels which could be implemented up to WinCC V5.1 have been discarded from the scope of delivery of WinCC V6.0 and higher. The following channels are no longer part of the scope of delivery: Allen Bradley DH DH+ DH485 Allen Bradley Serial DF1 Applicom Multi Protocol Interface GE Fanuc SNP SNPX Mitsubishi FX Modbus Protocol Suite Modbus Serial SIMATIC S5 PMC Ethernet SIMATIC S5 PMC Profibus SIPART SIMATIC S5 Ethernet TF (under Windows XP)

Windows DDE
The Windows DDE channel is included in the delivery since it is compatible to earlier WinCC versions. New connections, however, should be established using the "OPC" channel. An updated version of the Windows DDE channel is expected to be supplied with a later version of WinCC.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

35

Upgrading WinCC 7.3 How to Perform an Upgrade Installation

7.3

7.3

How to Perform an Upgrade Installation


If you currently have version WinCC V 5.0 SP2 or WinCC V5.1 installed on your system, you can perform an upgrade installation. Before beginning an upgrade installation, the transfer of existing projects must be prepared. Note If modified standard functions (ANSI-C) are used, make backup copies of the functions prior to the upgrade installation. During the WinCC installation process, these functions are overwritten by the standard functions supplied. Certain channels which could be implemented up to WinCC V5.1 have been discarded from the scope of delivery of WinCC V6.2. Also pay attention to the notes in the WinCC Information System under "Migration".

Introduction

Requirement
The hardware configuration on which WinCC V5.0 SP2 or V5.1 has been installed is also sufficient for installing an upgrade to WinCC V6.2. However, there should be no significant increase in data volume because otherwise the performance will get affected. If it is expected that the data volume will increase, upgrade the hardware in good time.

Upgrade Preparation
Before performing an upgrade installation of WinCC, check the existing projects with regard to special characters used in the archive names, archive tag names, trend names, trend window names, column names and table window names. You will find a table with the permitted special characters in the chapter "Working with WinCC" > "Working with Projects" > "References". It is possible that you must use Tag Logging in WinCC V5.0 SP2 or V5.1 to remove certain special characters from the names.

VBA Code
The "@GLOBAL.PDT" file in the <WinCC-Installationsverzeichnis\Templates > directory contains your global VBA extensions, for e.g. some menus. If you install WinCC V6.2, the file "@GLOBAL.PDT" is automatically renamed to "@GLOBAL.SAV" and replaced through a new file "@GLOBAL.PDT". First delete the new file "@GLOBAL.PDT" and again rename the "@GLOBAL.SAV" for accessing your VBA extensions after installing the upgrade. CAUTION When transferring archives, if they contain impermissible special characters, the Runtime archive may be lost.

Note Make a backup copy of your project before upgrading WinCC.

36

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Upgrading WinCC 7.3 How to Perform an Upgrade Installation

Procedure
1. Prepare existing WinCC projects for migration. Check which communication drivers are used and also check the names used for impermissible characters. 2. Install WinCC V6.2 as in "Executing Installation of WinCC". WinCC V5.0 SP2 or V5.1 need not be uninstalled for this purpose. You need the storage medium which contains the licenses for WinCC V6.2. Upgraded licenses for WinCC V5 will be lost.

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

37

Upgrading WinCC 7.3 How to Perform an Upgrade Installation

38

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Notes about Running the Software


Introduction

In order to operate WinCC without problems at optimum performance, please follow the Notes on Operation under Windows. Information on this is provided in the WinCC Information System under "Release Notes" > "Information on Operation" and "Working with Projects" > "Activate Project" > "External Applications".

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

39

Notes about Running the Software

40

Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

Index
A
Access right, 18, 19, 20 Domain, 14 execute, 28, 34, 36 Microsoft SQL Server 2005, 27 Migration, 34 Notes on installed software, 28 Notes on migration, 34 PDF files, 7 Perform uninstall, 31 Preparing the installation, 21 Requirements, 11, 12, 14 Supplemental Installation Performed Later, 30 Upgrading an Installation, 34, 36 Installation Guide, 5 Installation Notes, 5 Installed software, 28 Internet Explorer, 14

C
Client Operating system, 14 Communication driver, 7, 14 Component, 7, 28, 30 Communication driver, 7 Delivered Component, 7

D
Demo Mode, 9 Domain, 14 Domain-global user group, 20 Domains, 14

L
License, 9 Installation, 9 License Agreement, 9 License Type, 9

E
Event display, 31 External Applications, 39

M
Microsoft Message Queuing, 24 Microsoft SQL Server 2005, 9, 27, 31 Migration, 34 MS Message Queuing, 24

F
File sharing, 18 Folder, 18 Released folders, 18

O
Operating system, 14 Access rights, 18 Prevent access, 17 Operation, 39 Domain, 14

H
Hardware Requirement, 12

I
Installation, 5, 23, 27, 28 Adapting Security Policy, 21 Component, 28, 30 Database system, 27
Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help

41

Index

P
PDF files, 7 Project Include in user group, 20

User group SIMATIC HMI, 20 User Rights, 17

W R
Removal, 31 execute, 31 Requirement, 11 Hardware, 12 Operating system, 14 Software, 14 WinCC Install Microsoft SQL Server 2005, 27 Installation, 5, 11, 23 Installation Requirements, 12, 14 Limit access, 18 Perform uninstall, 31 Perform Uninstall, 28 Preparing the installation, 21 Supplemental Installation Performed Later, 30 upgrade, 33, 34 Upgrading an Installation, 34, 36 User Rights, 17 WinCC DVD, 7 WinCC DVD, 7 WinCC entity, 27 WinCC project Include in user group, 20 WinCC V5.0 SP2, 33, 34 WinCC V5.1, 33, 34 Windows, 14, 17, 18 Access rights, 18 Microsoft Message Queuing, 24 Operation under Windows, 39 Preparation the installation of WinCC, 21 Security policy, 21 Toolbar, 17 User Rights, 17, 18 Windows 2000, 14 Windows 2003 Server, 14 Windows event display, 31 Windows Server 2003, 14 Windows Server 2003 R2, 14 Windows Start Menu, 28 Windows XP, 14

S
Safety, 17, 18 Scope of Delivery, 7 Security policy, 21 Server Operating system, 14 Share, 18 SIMATIC HMI, 18, 19, 20 User group, 18 SIMATIC Security Control, 28 Software, 14 Requirement, 14 SQL database, 27 SQL Server, 27 User group, 19 SQL server entity, 27 SQLServer2005MSSQLUser, 19 SSC_Visual, 28 start menu, 28 Supplementary installation performed later, 30 execute, 30

T
Toolbar, 17

U
Upgrade Installation, 9, 34, 36 execute, 36 User group, 18 Domain-global user group, 20 Include project, 20 SIMATIC HMI, 18, 19, 20 SQLServer2005MSSQLUser, 18, 19
Installation Notes Software Installation Manual, 09/2007, Printout of the Online Help