Anda di halaman 1dari 23

CONTROLS

A Division of BRAY INTERNATIONAL, Inc.

Bray/McCannalok Butterfly Valves


Technical Manual
TM1023 - 12/12/2011

Bray/McCannalok
Butterfly Valves
Technical Manual - Table of Contents
Topic Page(s)
Seating & Unseating Torques..........................3
Imperial (Lb-Ins)................................................4-6
Metric (N-m).....................................................7-9
Dynamic Torque.................................................10-13
Maximum Shaft Torques (Lb-Ins) ....................14
Maximum Shaft Torques (N-m) .......................15
Valve Sizing Coefficients...............................16
Imperial (Cv).....................................................17-18
Metric (Kv)........................................................19-20
Pressure & Temperature Rating (F & C)
With PTFE Seats................................................21
With RTFE Seats................................................22
Flange to Valve Bolting Guide.........................23

All statements, technical information, and recommendations in this bulletin are for general use only.
Consult Bray representatives or factory for the specific
requirements and material selection for your intended
application. The right to change or modify product
design or product without prior notice is reserved.

Bray/McCannalok HPBV Seating & Unseating Torques

Seating & Unseating Torques:


Valve orientation to the flow of media affects the torque.
Torque values are presented in two categories:

FLOW

FLOW

Seat Retainer

UPSTREAM

Seat Retainer

DOWNSTREAM

FLOW

FLOW

Seat Retainer

UPSTREAM

Torque : 3

Seat Retainer

DOWNSTREAM

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Seating & Unseating Torques


ASME 150 - Torques (Lb-Ins)
Series 40/41/4A Standard - Valve Differential Pressure (PSIG)
Valve
Size
Inches

Less than 150 psig


Retainer Upstream

2.5
3
4
5
6
8
10
12
14
16
18
20
24
26
28
30
32
34
36
40
42
48
54
60

170
185
275
550
690
1,280
2,400
3,500
5,400
7,700
11,900
15,300
24,650
24,650
34,850
39,950
45,000
45,000
54,000
62,000
71,000
98,000
136,000

>150-200 psig

Retainer Downstream

200
220
320
650
810
1,500
2,800
4,100
6,300
9,100
14,000
18,000
29,000
29,000
41,000
47,000
53,000
53,000
64,000
73,000
83,000
115,000
160,000

Retainer Upstream

190
210
300
640
770
1,400
3,640
4,000
5,920
9,040
13,600
17,100
27,680
27,680
37,600
42,960
48,800
48,800
64,800
73,600
84,000
121,600
169,600

Retainer Downstream

240
260
370
800
960
1,700
3,300
5,000
7,400
11,300
17,000
21,300
34,600
34,600
47,000
53,700
61,000
61,000
81,000
92,000
105,000
152,000
212,000

>200-250 psig
Retainer Upstream

210
225
315
705
825
1,500
2,820
4,400
6,400
10,100
15,000
18,500
30,000
30,000
44,300
50,800
57,600
57,600
73,500
82,500
95,250
142,500
198,000

Retainer Downstream

>250-285 psig
Retainer Upstream

280
300
420
940
1,100
1,950
3,760
5,900
8,500
13,500
20,000
24,700
40,100
40,100
59,200
67,700
76,800
76,800
98,000
110,000
127,000
190,000
265,000

Retainer Downstream

215
230
320
730
840
1,570
2,870
4,550
6,650
10,500
15,400
18,900
30,800
30,800
44,500
52,500
58,800
58,800
77,000
84,700
101,000
151,900
211,400

300
320
460
1,040
1,200
2,100
4,100
6,500
9,500
15,000
22,000
27,000
44,000
44,000
63,500
75,000
84,000
84,000
110,000
121,000
143,000
217,000
302,000

710
780
910
1,600
1,900
2,860
4,400
6,900
13,600
16,320
19,200
28,800
50,400

840
900
1,100
1,850
2,100
3,200
5,100
8,100
17,000
20,400
24,000
36,000
63,000

Please Consult Factory

Series 40/41 Fire Safe - Valve Differential Pressure (PSIG)


2.5
3
4
5
6
8
10
12
14
16
18
20
24
26
28
30
32
34
36
40

Torque : 4

680
750
850
1,420
1,660
2,600
3,900
6,500
12,300
15,200
18,000
21,800
31,000

720
800
900
1,500
1,750
2,800
4,200
6,900
13,000
16,000
19,000
23,000
33,000

690
760
880
1,470
1,690
2,690
4,100
6,600
12,600
15,800
18,900
22,500
34,200

770
830
980
1,630
1,880
2,950
4,530
7,350
14,000
17,600
21,000
25,000
38,000

700
770
890
1,500
1,800
2,750
4,250
6,700
13,200
16,300
19,000
23,800
37,400

810
870
1,050
1,750
2,000
3,100
4,860
7,790
15,500
19,200
22,500
28,000
44,000

Please Consult Factory


Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Seating & Unseating Torques


ASME 300 - Torques (Lb-Ins)
Series 42/43/4B Standard - Valve Differential Pressure (PSIG)
Valve
Size
Inches

Less than 150 psig


Retainer Upstream

2.5
3
4
5
6
8
10
12
14
16
18
20
24
30
36
40
48
54

170
185
270
550
850
1,580
2,800
4,250
7,300
11,900
15,300
20,400
32,300
68,000
101,150
115,600
127,500

>150-350 psig

Retainer Downstream

200
220
320
650
1,000
1,850
3,300
5,000
8,600
14,000
18,000
24,000
38,000
80,000
119,000
136,000
150,000

Retainer Upstream

290
310
420
1,000
1,320
2,480
4,400
6,640
10,720
17,200
21,600
29,400
45,600
101,600
144,000
168,000
217,600

Retainer Downstream

360
380
530
1,250
1,650
3,100
5,500
8,300
13,400
21,500
27,000
36,700
57,000
127,000
180,000
210,000
272,000

>350-550 psig
Retainer Upstream

380
400
550
1,390
1,720
3,230
5,700
8,630
13,700
21,800
27,100
37,000
57,500
129,000
180,000
222,000
321,000

Retainer Downstream

>550-740 psig
Retainer Upstream

510
530
730
1,850
2,300
4,300
7,600
11,500
18,300
29,000
36,100
49,300
76,700
172,000
240,000
296,000
428,000

Retainer Downstream

470
490
700
1,800
2,100
3,700
7,000
10,500
15,400
26,600
31,500
42,700
66,500
147,000
203,000
278,600
403,200

670
690
1,000
2,550
3,000
5,300
10,000
15,000
22,000
38,000
45,000
61,000
95,000
210,000
290,000
398,000
576,000

880
960
1,360
2,880
3,440
4,960
12,000
16,800
22,400
39,200

1,100
1,200
1,700
3,600
4,300
6,200
15,000
21,000
28,000
49,000

Please Consult Factory

Series 42/43 Fire Safe - Valve Differential Pressure (PSIG)


2.5
3
4
5
6
8
10
12
14
16
18
20
24

Torque : 5

680
750
850
1,420
2,000
3,000
6,900
10,450
18,050
26,600

720
800
900
1,500
2,100
3,150
7,300
11,000
19,000
28,000

775
855
1,080
2,070
2,610
3,870
9,180
13,200
21,600
34,200

860
950
1,200
2,300
2,900
4,300
10,200
14,700
24,000
38,000

860
935
1,275
2,635
3,150
4,675
11,050
15,640
22,100
37,400

1,010
1,100
1,500
3,100
3,700
5,500
13,000
18,400
26,000
44,000

Please Consult Factory


Please Consult Factory
Please Consult Factory

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Seating & Unseating Torques


ASME 600 - Torques (Lb-Ins)
Series 44/45 Standard - Valve Differential Pressure (PSIG)
Valve
Size
Inches

Less than 150 psig


Retainer Upstream

3
4
6
8
10
12
14
16
18
20
24
30

400
850
1,450
3,500
7,100
10,100
11,900
14,000
16,200
21,300
33,000
71,000

>150-600 psig

Retainer Downstream

480
960
1,700
4,100
8,300
11,800
14,000
16,500
19,000
25,000
39,000
83,000

Retainer Upstream

700
1,280
2,560
5,760
9,600
11,200
19,200
28,400
34,400
45,600
71,000
137,000

Retainer Downstream

870
1,600
3,200
7,200
12,000
14,000
24,000
35,500
43,000
57,000
89,000
172,000

>600-1050 psig
Retainer Upstream

900
1,580
3,450
7,600
13,500
19,500
24,800
34,500
49,000
66,000
94,000
180,000

Retainer Downstream

>1050-1480 psig
Retainer Upstream

1,200
2,100
4,600
10,100
18,000
26,000
33,000
46,000
65,000
88,000
125,000
240,000

1,000
1,900
4,100
9,800
16,800
21,000
30,000
45,500
64,400
87,000
123,000
217,000

Retainer Downstream

1,450
2,700
5,800
14,000
24,000
30,000
43,000
65,000
92,000
124,000
175,000
310,000

Series 44/45 Fire Safe - Valve Differential Pressure (PSIG)


3
4
6
8
10
12
14

Torque : 6

Please Consult Factory


Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Seating & Unseating Torques


ASME 150 - Torques (N-m)
Series 40/41/4A Standard - Valve Differential Pressure (Bar)
Valve
Size
mm

Less than 10.3 Bar


Retainer Upstream

65
80
100
125
150
200
250
300
350
400
450
500
600
650
700
750
800
850
900
1,000
1,050
1,200
1,350
1,500

19
21
31
62
78
145
271
396
610
870
1,345
1,729
2,785
2,785
3,938
4,514
5,085
5,085
6,102
7,006
8,023
11,074
15,368

>10.3-14 Bar

Retainer Downstream

23
25
36
73
92
170
316
463
712
1,028
1,582
2,034
3,277
3,277
4,633
5,311
5,989
5,989
7,232
8,249
9,379
12,995
18,080

Retainer Upstream

21
24
34
72
87
158
411
452
669
1,022
1,537
1,932
3,128
3,128
4,249
4,854
5,514
5,514
7,322
8,317
9,492
13,741
19,165

>14-17.2 Bar

Retainer Downstream

27
29
42
90
108
192
373
565
836
1,277
1,921
2,407
3,910
3,910
5,311
6,068
6,893
6,893
9,153
10,396
11,865
17,176
23,956

Retainer Upstream

24
25
36
80
93
170
319
497
723
1,141
1,695
2,091
3,390
3,390
5,006
5,740
6,509
6,509
8,306
9,323
10,763
16,103
22,374

>17.2-20 Bar

Retainer Downstream

32
34
47
106
124
220
425
667
961
1,526
2,260
2,791
4,531
4,531
6,690
7,650
8,678
8,678
11,074
12,430
14,351
21,470
29,945

Retainer Upstream

Retainer Downstream

24
26
36
82
95
177
324
514
751
1,187
1,740
2,136
3,480
3,480
5,029
5,933
6,644
6,644
8,701
9,571
11,413
17,165
23,888

34
36
52
118
136
237
463
735
1,074
1,695
2,486
3,051
4,972
4,972
7,176
8,475
9,492
9,492
12,430
13,673
16,159
24,521
34,126

80
88
103
181
215
323
497
780
1,537
1,844
2,170
3,254
5,695

95
102
124
209
237
362
576
915
1,921
2,305
2,712
4,068
7,119

Please Consult Factory

Series 40/41 Fire Safe - Valve Differential Pressure (Bar)


65
80
100
125
150
200
250
300
350
400
450
500
600
650
700
750
800
850
900
1,000

Torque : 7

77
85
96
160
188
294
441
735
1,390
1,718
2,034
2,463
3,503

81
90
102
170
198
316
475
780
1,469
1,808
2,147
2,599
3,729

78
86
99
166
191
304
463
746
1,424
1,785
2,136
2,543
3,865

87
79
94
87
111
101
184
170
212
203
333
311
512
480
831
757
1,582
1,492
1,989
1,842
2,373
2,147
2,825
2,689
4,294
4,226
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory

92
98
119
198
226
350
549
880
1,752
2,170
2,543
3,164
4,972

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Seating & Unseating Torques


ASME 300 - Torques (N-m)
Series 42/43/4B Standard - Valve Differential Pressure (Bar)
Valve
Size
mm

Less than 10.3 Bar


Retainer Upstream

65
80
100
125
150
200
250
300
350
400
450
500
600
750
900
1,000
1,200
1,350

19
21
31
62
96
179
316
480
825
1,345
1,729
2,305
3,650
7,684
11,430
13,063
14,408

>10.3-24 Bar

Retainer Downstream

23
25
36
73
113
209
373
565
972
1,582
2,034
2,712
4,294
9,040
13,447
15,368
16,950

Retainer Upstream

33
35
47
113
149
280
497
750
1,211
1,944
2,441
3,322
5,153
11,481
16,272
18,984
24,589

Retainer Downstream

>24-38 Bar
Retainer Upstream

41
43
43
45
60
62
141
157
186
194
350
365
622
644
938
975
1,514
1,548
2,430
2,463
3,051
3,062
4,147
4,181
6,441
6,498
14,351
14,577
20,340
20,340
23,730
25,086
30,736
36,273
Please Consult Factory

>38-51 Bar

Retainer Downstream

Retainer Upstream

58
60
82
209
260
486
859
1,300
2,068
3,277
4,079
5,571
8,667
19,436
27,120
33,448
48,364

Retainer Downstream

53
55
79
203
237
418
791
1,187
1,740
3,006
3,560
4,825
7,515
16,611
22,939
31,482
45,562

76
78
113
288
339
599
1,130
1,695
2,486
4,294
5,085
6,893
10,735
23,730
32,770
44,974
65,088

99
108
154
325
389
560
1,356
1,898
2,531
4,430

124
136
192
407
486
701
1,695
2,373
3,164
5,537

Series 42/43 Fire Safe - Valve Differential Pressure (Bar)


65
80
100
125
150
200
250
300
350
400
450
500
600

Torque : 8

77
85
96
160
226
339
780
1,181
2,040
3,006

81
90
102
170
237
356
825
1,243
2,147
3,164

88
97
122
234
295
437
1,037
1,492
2,441
3,865

97
97
107
106
136
144
260
298
328
356
486
528
1,153
1,249
1,661
1,767
2,712
2,497
4,294
4,226
Please Consult Factory
Please Consult Factory
Please Consult Factory

114
124
170
350
418
622
1,469
2,079
2,938
4,972

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Seating & Unseating Torques


ASME 600 - Torques (N-m)
Series 44/45 Standard - Valve Differential Pressure (Bar)
Less than 10.3 Bar

Valve
Size
mm

Retainer Upstream

80
100
150
200
250
300
350
400
450
500
600
750

45
96
164
396
802
1,141
1,345
1,582
1,831
2,407
3,729
8,023

>10.3-41.4 Bar

Retainer Downstream

54
108
192
463
938
1,333
1,582
1,865
2,147
2,825
4,407
9,379

Retainer Upstream

79
145
289
651
1,085
1,266
2,170
3,209
3,887
5,153
8,023
15,481

Retainer Downstream

98
181
362
814
1,356
1,582
2,712
4,012
4,859
6,441
10,057
19,436

>41.4-72.4 Bar
Retainer Upstream

102
179
390
859
1,526
2,204
2,802
3,899
5,537
7,458
10,622
20,340

Retainer Downstream

136
237
520
1,141
2,034
2,938
3,729
5,198
7,345
9,944
14,125
27,120

>72.4-102 Bar
Retainer Upstream

113
215
463
1,107
1,898
2,373
3,390
5,142
7,277
9,831
13,899
24,521

Retainer Downstream

164
305
655
1,582
2,712
3,390
4,859
7,345
10,396
14,012
19,775
35,030

Series 44/45 Fire Safe - Valve Differential Pressure (Bar)


80
100
150
200
250
300
350

Torque : 9

Please Consult Factory


Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory
Please Consult Factory

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Dynamic Torques

Dynamic Torques:

When a media flows through a butterfly valve, static pressure


does not act uniformly on the surfaces of the valve disc. Dynamic
torque will cause rotary motion when unchecked by the actuator
or manual operator possibly resulting in opening or closing of the
valve. If the dynamic torque is of a magnitude that is greater than
the bearing and packing friction torque and there is no actuator
in place to maintain disc position, the opening or closing action
could result in injury to operating personnel or an interruption of
the process. Sudden closure (slamming) can cause water hammer
damage in lines carrying liquid.

In high performance butterfly valves which have the disc


offset from the stem and have non-symmetrical disc faces,
dynamic torque acts to close the valve if the valve is installed
Pressure but
Distribution
with the seat retainer downstream,
can act to close or open
the valve, depending on the position of the disc, if the seat retainer is upstream.

Liquid Flow:
Imperial....... Td (Lb-inches) = Ct D p
Metric.......... Td (N-m) = .0001 Ct D p
Gas Flow:
Imperial....... Td (Lb-inches) = Ct D Y p
Metric.......... Td (N-m) = .0001 Ct D Y p

Dynamic Torque - Terminology


Ct - dynamic torque coefficient (see graphs and tables on

Pg. 12 for values of Ct.) Positive value of Ct means that


the dynamic torque acts to close the valve and a negative value of Ct to open the valve.

Seat Retainer Upstream

D - nominal valve size (inch or mm)


Fk - ratio of specific heat factor (dimensionless)

FLOW

Seat Retainer Downstream

FLOW
Dynamic torque should be calculated as part of the valve actuator sizing procedure or to determine if hand lever operation is acceptable. In this regard, the total torque of all service conditions
must be considered.
The total torque when the disc is in the seat consists of:
1. Seating torque
2. Stem packing torque
3. Eccentricity torque
4. Stem bearing torque
The total torque when the disc is in the seat is published as seating/unseating torque. When the disc is out of the seat, the total
torque consists of dynamic torque, stem packing torque, and stem
bearing torque.
Total torque changes with the disc position. Maximum total
torque can occur at shutoff (disc in the seat), at breakaway (motion initiation), or at any open disc position where the product
of valve pressure drop and dynamic torque coefficient peaks in
combination with prevailing bearing and packing torque.
Dynamic : 10

Estimating Dynamic Torque


Dynamic torque can be estimated using the following
empirical equations:

kp p1 Td xY-

Fk = k/1.40 or Fk = 1 for air

ratio of specific heat (dimensionless)


effective pressure drop across the valve (psi or bar)
valve inlet pressure (psia or bar abs.)
dynamic torque (Lb-inches or N-m)
x = p/p1

gas expansion factor (dimensionless)


Y = 1 x / (3 Fk xt)

xt - gas critical pressure ratio (dimensionless)

Values of xt change with disc position and are identical for seat retainer upstream and downstream.
Open

xt

Open

xt

10

0.46

55

0.31

15

0.46

60

0.28

20

0.46

65

0.27

25

0.45

70

0.25

30

0.44

75

0.24

35

0.42

80

0.22

40

0.39

85

0.21

45

0.35

90

0.19

50

0.33

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Dynamic Torques


For:

Condition: Use:
Pipe and
Valve Size
Equal

Nominal Valve Size


Valve Pressure Drop
Ct from graphs/tables on pg. 12

W/ Pipe
Reducers

Nominal Valve Size


Ct from graphs/tables on pg. 12
Valve Pressure Drop as if valve
were installed in valve-sized
pipe with same flow rate

Pipe and
Valve Size
Equal

Nominal Valve Size


Ct from graphs/tables on pg. 12
Actual Pressure drop through
valve.

If actual pressure drop at the choked condition is


not known, estimate by evaluating the pressure in
the piping at the valve outlet needed to sustain the
choked flow rate through the piping downstream
of the valve; then subtracting it from the valve inlet
pressure.

Nominal Valve Size


Ct from graphs/tables on pg. 12
Actual pressure drop through
valve/reducer assembly.

If the pressure drop at the choked condition is


not known, estimate the line pressure just downstream of the valve/reducer assembly which is
needed to sustain the choked flow rate of the
valve/reducer assembly through the downstream
piping; then subtract this pressure from the line
pressure just ahead of the valve/reducer assembly,
to get the actual pressure drop.

Subchoked
Flow

Choked Flow
W/ Pipe
Reducers

For:

Note:

Condition: Use:

Note:

Pipe and
Valve Size
Equal

Nominal Valve Size


Valve Pressure Drop
Ct from graphs/tables on pg. 12

W/ Pipe
Reducers

Nominal Valve Size


Ct from graphs/tables on pg. 12
Valve Pressure Drop (and expansion factor
Y) as if valve were installed in valve-sized
pipe with same flow rate.

In calculating Y, use the line pressure


just upstream of the inlet reducer for p1
and xt from the table on page 10.

Pipe and
Valve Size
Equal

Nominal Valve Size


Gas expansion factor Y of 2/3
Ct from graphs/tables on pg. 12
p = p1 Fk xt

Use xt from the table on page 10.

W/ Pipe
Reducers

Nominal Valve Size


Gas expansion factor Y of 2/3
Ct from graphs/tables on pg. 12
p = p1 Fk xt

Use the line pressure just upstream


of the inlet reducer for p1 and xt from
the table above in calculating p,
on page 10.

Subchoked
Flow

Choked Flow

Dynamic : 11

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Dynamic Torques

Dynamic Torque Coefficient

Figure 3. Ct values with the Seat Retainer Down Stream


McCannalok Dynamic Torque Coefficient
Seat Retainer Downstream
0.55
0.50
0.45
0.40
0.35
0.30
0.25
0.20
0.15
0.10
0.05
0

Dynamic Torque Coefficient

Angle of Opening
Ct Down

0.15
0.10
0.05
0
-0.05
-0.10
-0.15
-0.20
-0.25
-0.30
-0.35

Figure 4. Ct values with the Seat Retainer Up Stream


McCannalok Dynamic Torque Coefficient
Seat Retainer Upstream
!

-0.40

Angle of Opening
Ct up

Dynamic : 12

0 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
.0 .012 .022 .031 .044 .058 .073 .088 .114 .141 .176 .212 .260 .308 .370 .431 .496 .362

0 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
.0 .015 .018 .020 .023 .027 .037 .046 .055 .063 .078 .086 .093 .100 .084 .032 -.17 -.37

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Dynamic Torques


1. Subchoked Liquid Flow, Line-size Valve.
Example Calculations:

A 24 class 150 McCannalok is to be installed in a 24


line carrying water. It has been determined that the flow
is not choked and the following pressure drops through
the valve have been calculated:

Data:







75 psi with the valve 20 degrees open


70 psi with the valve 30 degrees open
35 psi with the valve 40 degrees open
3.5 psi with the valve 55 degrees open
1.1 psi with the valve 60 degrees open
.20 psi with the valve 70 degrees open
.05 psi with the valve 80 degrees open
.03 psi with the valve 90 degrees open

20 degrees, Td = .020 x 24 x 75 = 20,700 Lb-inches,


(tends to close the valve)
30 degrees, Td = .027 x 24 x 70 = 26,100 Lb-inches
40 degrees, Td = .046 x 24 x 35 = 22,300 Lb-inches
55 degrees, Td = .078 x 24 x 3.5 = 3,800 Lb-inches
60 degrees, Td = .086 x 24 x 1.1 = 1,300 Lb-inches
70 degrees, Td = .100 x 24 x .20 = 300 Lb-inches
80 degrees, Td = .032 x 24 x .05 = 20 Lb-inches
90 degrees, Td = -.369 x 24 x .03 = -150 Lb-inches,
(tends to open the valve)

Estimate the maximum dynamic torque in Lb-inches for the valve Td = Ct D p


considering installation with the seat retainer upstream.

Substituting produces following results:

Thus the peak dynamic torque will occur between 30 and 40 degrees open.
Verify dynamic torque at 35 degrees:
Approximate pressure drop = (70+35)/2 = 52.5 psi.
At 35 degrees: Td = .037 x 24 x 52.5 = 27,000 Lb-inches
The peak dynamic torque of approximately 27,000 Lb-inches occurs at about 35 degrees open.
When sizing the valve operator, total torque must be considered. The total torque when the disc is in the seat consists of seating torque, stem packing torque, eccentricity torque and stem bearing torque. The total torque when
the disc is in the seat is published as seating/unseating torque (see pages 1-6. When the disc is out of the seat, total
torque consists of dynamic torque, stem packing torque, and stem bearing torque.

2. Choked Gas Flow, Reduced-size Valve.


Example Calculations:

20 (DN 500) class 300 McCannalok butterfly valve is installed in a 600 mm (24) line flowing air and the disc is
set at 45 degrees. The flow is choked. A pressure gauge tapped into the pipe just above the upstream reducer shows
24.5 bar.
Estimate the dynamic torque in N-m, given that the seat D = 500 mm
Fk = 1.0
retainer is installed downstream.
Ct = .114
Y = .667 for choked flow
p1 = 24.5 + 1.0 = 25.5 bar absolute, (1 atm. = 1.013
bar, i.e. about 1.0 bar)
xt at 45 = .35
Calculations:
p = p1 Fk xt
Td = .0001 Ct D Y p
p = 25.5 x 1.0 x .35 = 8.9 bar
Td = .0001 x .114 x 500 x .667 x 8.9 = 8,500 N-m
Thus the dynamic torque at 45 open is about 8,500 N-m, and acts to close the valve.

Dynamic : 13

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Maximum Allowable Shaft Torques


Maximum Allowable Shaft Torques (Lb-Ins)*
Standard & Fire Safe Valves

ASME 150
Series S40/41/4A

ASME 300
Series S42/43/4B

2.5

1,776

1,776

NA

1,776

1,776

2,980

1,776

1,776

5,101

2,980

2,980

2,980

5,101

13,107

5,101

13,107

22,779

10

13,107

22,779

72,679

12

13,107

22,779

72,679

14

22,779

72,679

142,582

16

72,679

142,582

246,277

18

72,679

142,582

423,121

20

142,582

202,665

625,210

24

202,665

423,121

1,059,387

26

202,665

Please Consult Factory

28

246,277

Please Consult Factory

30

423,121

840,799

32

423,121

Please Consult Factory

34

423,121

Please Consult Factory

36

423,121

1,059,387

40

840,799

1,929,311

42

840,799

1,929,311

48

1,059,387

2,185,227

54

1,242,673

3,254,310

Valve
Size
inches

60

ASME 600
Series 44/45

Please Consult Factory

Please Consult Factory

Please Consult Factory

* Based on shaft Material Code 50J (17-4 PH stainless steel, ASTM A564 Type 630 H1075)

Shaft Torque : 14

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Maximum Allowable Shaft Torques


Maximum Allowable Shaft Torques (N-m)*
Standard & Fire Safe Valves

ASME 150
Series S40/41/4A

ASME 300
Series S42/43/4B

65

201

201

NA

80

201

201

337

100

201

201

576

125

337

337

150

337

576

1,481

200

576

1,481

2,574

250

1,481

2,574

8,213

300

1,481

2,574

8,213

350

2,574

8,213

16,112

400

8,213

16,112

27,829

450

8,213

16,112

47,813

500

16,112

22,901

70,649

600

22,901

47,813

119,711

650

22,901

Please Consult Factory

700

27,829

Please Consult Factory

750

47,813

800

47,813

Please Consult Factory

850

47,813

Please Consult Factory

900

47,813

119,711

1,000

95,010

218,012

1,050

95,010

218,012

1,200

119,711

246,931

1,350

140,422

367,737

Valve
Size
mm

1,500

95,010

ASME 600
Series 44/45

Please Consult Factory

Please Consult Factory

Please Consult Factory

* Based on shaft Material Code 50J (17-4 PH stainless steel, ASTM A564 Type 630 H1075)

Shaft Torque : 15

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Valve Sizing Coefficients

Valve Sizing Coefficients:


1. Valve Sizing Coefficients (Cv). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 15-16

1. Cv stands for Valve Sizing Coefficient.


2. Cv varies with the valve size, angle of opening and the manufacturers valve style.
3. Cv is defined as the volume of water in USGPM that will flow through a given restriction or valve
opening with a pressure drop of one (1) psi at room temperature.

2. Valve Sizing Coefficients (Kv). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pages 17-18

1. Kv stands for Valve Sizing Coefficient.


2. Kv varies with the valve size, angle of opening and the manufacturers valve style.
3. Kv is defined as the volume of water in Cubic Meters/Hour (m3/hr) that will flow through a given
restriction or valve opening with a pressure drop of one (1) bar at room temperature.

Coefficients : 16

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Valve Sizing Coefficients


ASME 150 Series 40/41/4A - Valve Sizing Coefficient (Cv)
Valve
Size
Inches

2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
26
28
30
32
34
36
40
42
48
54
60

Disc Position (Degrees)


90
160
185
375
790
1,350
2,800
4,300
6,650
7,650
9,800
10,500
13,500
20,000
20,000
28,000
32,000
34,000
34,000
48,500
62,000
65,000
91,000
125,000
160,000

Coefficients : 17

80
136
178
365
675
1,070
2,230
3,450
5,330
6,100
7,860
9,100
11,700
17,100
17,100
23,900
27,300
29,100
29,100
41,100
55,200
58,000
80,900
111,000
140,000

70
100
155
315
500
750
1,590
2,430
3,750
4,300
5,510
6,960
8,800
12,800
12,800
18,200
20,900
22,300
22,300
31,700
44,000
46,100
63,700
87,500
105,000

60

50

40

30

78
123
250
360
510
1,060
1,630
2,530
2,900
3,700
5,100
6,500
9,570
9,570
13,500
15,500
16,500
16,500
23,200
33,300
35,000
43,600
60,000
75,000

50
87
175
238
330
685
1,050
1,630
1,890
2,420
3,520
4,500
6,640
6,640
9,300
10,700
11,400
11,400
16,400
23,800
25,000
29,100
40,000
50,000

30
56
115
146
218
456
700
1,080
1,250
1,530
2,220
2,820
3,880
3,880
5,700
6,700
7,150
7,150
10,200
15,200
16,000
20,000
27,500
31,000

16
32
63
78
140
280
450
700
810
1,020
1,180
1,530
2,200
2,200
3,100
3,600
3,850
3,850
5,430
8,600
9,000
11,000
15,000
17,000

20
8
14
31
41
81
165
250
390
450
580
500
640
920
920
1,300
1,510
1,610
1,610
2,260
3,520
3,700
4,600
6,000
7,000

10
3
5
10
16
35
65
100
155
175
230
170
200
240
240
290
320
340
340
480
670
700
920
1,200
1,400

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Valve Sizing Coefficients


ASME 300 Series 42/43/4B - Valve Sizing Coefficient (Cv)
Valve
Size
Inches

2 1/2
3
4
5
6
8
10
12
14
16
18
20
24
30
36
42
48
54

Disc Position (Degrees)


90
160
185
375
790
1,000
2,000
2,650
4,000
4,100
7,800
9,500
11,000
18,000
29,000
45,000
60,000
83,000

80
136
178
365
675
875
1,720
2,250
3,400
3,500
6,540
8,000
9,570
15,100
24,400
38,100
54,000
74,000

70
100
155
315
500
710
1,360
1,740
2,500
2,600
4,550
6,170
7,300
11,400
18,900
29,200
42,000
58,000

60

50

40

30

78
123
250
360
530
950
1,200
1,690
1,770
2,970
4,530
5,400
8,570
13,700
21,000
30,000
41,000

50
87
175
238
370
630
780
1,100
1,200
1,840
3,110
3,720
5,920
8,500
14,800
19,000
26,000

30
56
115
146
240
405
510
710
830
1,160
1,970
2,330
3,700
6,000
9,100
13,000
17,000

16
32
63
78
138
240
295
430
490
730
1,080
1,250
2,000
3,230
4,660
7,500
10,000

20
8
14
31
41
79
121
150
220
240
420
440
530
830
1,330
1,730
2,600
4,400

10
3
5
10
16
26
47
61
92
100
180
94
110
180
290
380
450
800

Please Consult Factory

ASME 600 Series 44/45 - Valve Sizing Coefficient (Cv)


Valve
Size
Inches

3
4
6
8
10
12
14
16
18
20
24
30

Disc Position (Degrees)


90
165
300
800
1,500
2,200
3,100
3,900
5,000
6,000
8,000
11,000
15,000

Coefficients : 18

80
158
270
765
1,350
1,970
2,790
3,300
4,200
5,000
6,900
9,300
13,000

70
135
210
600
1,050
1,540
2,170
2,400
2,900
3,900
5,300
7,000
10,000

60
103
150
425
750
1,100
1,550
1,570
1,900
2,800
3,900
5,200
8,400

50
67
95
270
480
700
1,000
1,100
1,200
1,900
2,700
3,600
5,100

40
46
70
200
345
500
680
730
800
1,200
1,700
2,250
2,800

30
12
45
130
209
300
400
420
500
660
950
1,200
1,650

20
8
30
70
78
140
190
200
250
290
400
500
600

10
3
5
15
20
40
55
70
95
130
143
180
200

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Valve Sizing Coefficients


ASME 150 Series 40/41/4A - Valve Sizing Coefficient (Kv)
Valve
Size
mm

65
80
100
125
150
200
250
300
350
400
450
500
600
650
700
750
800
850
900
1,000
1,050
1,200
1,350
1,500

Disc Position (Degrees)


90
136
158
320
674
1,152
2,388
3,668
5,672
6,525
8,359
8,957
11,516
17,060
17,060
23,884
27,296
29,002
29,002
41,371
52,886
55,445
77,623
106,625
136,480

Coefficients : 19

80
116
152
311
576
913
1,902
2,943
4,546
5,203
6,705
7,762
9,980
14,586
14,586
20,387
23,287
24,822
24,822
35,058
47,086
49,474
69,008
94,683
119,420

70

60

50

40

30

85
132
269
427
640
1,356
2,073
3,199
3,668
4,700
5,937
7,506
10,918
10,918
15,525
17,828
19,022
19,022
27,040
37,532
39,323
54,336
74,638
89,565

67
105
213
307
435
904
1,390
2,158
2,474
3,156
4,350
5,545
8,163
8,163
11,516
13,222
14,075
14,075
19,790
28,405
29,855
37,191
51,180
63,975

43
74
149
203
281
584
896
1,390
1,612
2,064
3,003
3,839
5,664
5,664
7,933
9,127
9,724
9,724
13,989
20,301
21,325
24,822
34,120
42,650

26
48
98
125
186
389
597
921
1,066
1,305
1,894
2,405
3,310
3,310
4,862
5,715
6,099
6,099
8,701
12,966
13,648
17,060
23,458
26,443

14
27
54
67
119
239
384
597
691
870
1,007
1,305
1,877
1,877
2,644
3,071
3,284
3,284
4,632
7,336
7,677
9,383
12,795
14,501

20
7
12
26
35
69
141
213
333
384
495
427
546
785
785
1,109
1,288
1,373
1,373
1,928
3,003
3,156
3,924
5,118
5,971

10
3
4
9
14
30
55
85
132
149
196
145
171
205
205
247
273
290
290
409
572
597
785
1,024
1,194

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Valve Sizing Coefficients


ASME 300 Series 42/43/4B - Valve Sizing Coefficient (Kv)
Valve
Size
mm

65
80
100
125
150
200
250
300
350
400
450
500
600
750
900
1,050
1,200
1,350

Disc Position (Degrees)


90
136
158
320
674
853
1,706
2,260
3,412
3,497
6,653
8,104
9,383
15,354
24,737
38,385
51,180
70,799

80
116
152
311
576
746
1,467
1,919
2,900
2,986
5,579
6,824
8,163
12,880
20,813
32,499
46,062
63,122

70

60

50

40

85
132
269
427
606
1,160
1,484
2,133
2,218
3,881
5,263
6,227
9,724
16,122
24,908
35,826
49,474

67
105
213
307
452
810
1,024
1,442
1,510
2,533
3,864
4,606
7,310
11,686
17,913
25,590
34,973

43
74
149
203
316
537
665
938
1,024
1,570
2,653
3,173
5,050
7,251
12,624
16,207
22,178

26
48
98
125
205
345
435
606
708
989
1,680
1,987
3,156
5,118
7,762
11,089
14,501

30
14
27
54
67
118
205
252
367
418
623
921
1,066
1,706
2,755
3,975
6,398
8,530

20
7
12
26
35
67
103
128
188
205
358
375
452
708
1134
1476
2218
3753

10
3
4
9
14
22
40
52
78
85
154
80
94
154
247
324
384
682

Please Consult Factory

ASME 600 Series 44/45 - Valve Sizing Coefficient (Kv)


Valve
Size
Inches

80
100
150
200
250
300
350
400
450
500
600
750

Disc Position (Degrees)


90
141
256
735
1,280
1,877
2,644
3,327
4,265
5,118
6,824
9,383
12,795

Coefficients : 20

80
135
230
662
1,152
1,680
2,380
2,815
3,583
4,265
5,886
7,933
11,089

70
115
179
519
896
1,314
1,851
2,047
2,474
3,327
4,521
5,971
8,530

60
88
128
368
640
938
1,322
1,339
1,621
2,388
3,327
4,436
7,165

50
57
81
234
409
597
853
938
1,024
1,621
2,303
3,071
4,350

40
39
60
173
294
427
580
623
682
1,024
1,450
1,919
2,388

30
10
38
112
178
256
341
358
427
563
810
1,024
1,407

20
7
26
61
67
119
162
171
213
247
341
427
512

10
3
4
13
17
34
47
60
81
111
122
154
171

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

20

40

80

100

Carbon Steel Body

400

RTFE Seats

200
Bray/McCannalok HPBV Pressure & Temperature

300
100

200
100

ASME 150

ASME 300

ASME 600

0
-20
0

200

400

20

600

800
1000
Pressure psig

40

Pressure Bar
60

With PTFE Seats:

1200

80

1400

100
300

Temperature F

500
Stainless Steel Body

400

PTFE Seats

200

300
100

200
100

ASME 150

0
-20
0

600

ASME 300

200

400

20

600

40

ASME 600

800
1000
Pressure psig
Pressure Bar
60

1200

80

0
1400

-29
1600

100
300

500
Temperature F

-29
1600

Temperature C

600

Temperature C

300

500
Temperature F

Pressure Bar
60

Carbon Steel Body

400

PTFE Seats

200

300
100

200
100

ASME 150

ASME 300

ASME 600

0
-20
0

Press/Temp : 21

200

400

600

800
1000
Pressure psig

1200

1400

Temperature C

600

-29
1600

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Bray/McCannalok HPBV Pressure & Temperature

With RTFE Seats:


20

40

Pressure Bar
60

80

100

100

200
100

ASME 150

600

ASME 300

200

400

20

600

40

ASME 600

800
1000
Pressure psig
Pressure Bar
60

1200

80

0
1400

-29
1600

100
300

500

Carbon Steel Body

400

RTFE Seats

200

300
100

200
100

ASME 150

ASME 300

ASME 600

0
-20
0

600

200

400

20

600

800
1000
Pressure psig

40

Pressure Bar
60

1200

80

1400

-29
1600

100
300

500
Temperature F

200

300

0
-20

Temperature F

RTFE Seats

Stainless Steel Body

400

PTFE Seats

200

300
100

200
100

0
-20
Press/Temp : 022

Temperature C

Temperature F

Stainless Steel Body

400

Temperature C

300

500

ASME 150

ASME 300

ASME 600

0
-29

Temperature C

600

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
600 only. Product suitability
800 should be1000
1200 detailed knowledge
1400 and experience
1600
The200
technical data herein400
is for general information
based solely upon customers
with their application.

Pressure psig

Bray/McCannalok HPBV Flange to Valve Bolting Guide

Examples of Typical Flange to Valve Bolting*


** Lug Style Bolting

Seat Retainer
Gasket

Gasket

Raised
Face
Flange

Raised
Face
Flange

Valve Body

Washer

Washer
**Minimum Bolt
Engagement
Must Be Equal to
Diameter of Bolt

**Minimum Bolt
Engagement
Must Be Equal to
Diameter of Bolt

Flange Width

Including Raise Face


If Applicable
Necessary

Gasket
Width

Seat
Retainer
Width

Minimum Bolt
Engagement
Equal to
Bolt Diameter

Bolt
= Length

Washer
Width

Seat Retainer
Side ONLY!

** Wafer Style Bolting

Seat Retainer
Gasket

Gasket

Flat Face
Flange

Flat Face
Flange

Washer
Flange
Width x2

Including Raise Face


If Applicable

Gasket
Width
x2

Washer

Valve Face to Face

Valve
Face to
Face

Washer
Width
x2

Width
of Nut
x2

4 Threads
(2 Per Side)

= Overall
Length

Note:
** Note:
Please
Please
refer
refer
to Appropriate
to Appropriate
Bray
Bray
Technical
Dimensional
Drawings for Dimensions
specific valveand
drilling
Bolting
information
information
.
for the highlighted holes.
Applies to Wafer and Lug Valves as follows:
ASME Class 150 =26
26Valves
Valvesand
andlarger
larger
ASME Class
Class 300
300 =14
ASME
14Valves
Valvesand
andlarger
larger
ASME Class 600 10 Valves and larger
ASME Class 650 = 10 Valves and larger

Please refer to ASME B-16.5 or B-16.47 for Flange and Bolt Dimension Information
* Double flange style bolting not shown.
** Lug Threads may be tapped from both sides and therefore tap may not be continuous.

Flange Bolting : 23

All information herein is proprietary and confidential and may not be copied or reproduced without the expressed written consent of BRAY INTERNATIONAL, Inc.
The technical data herein is for general information only. Product suitability should be based solely upon customers detailed knowledge and experience with their application.

Anda mungkin juga menyukai