Evolution
650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U

Installation and User Manual Manuel dinstallation et dutilisation Manual de instalacin y uso Instalao e manual do usurio

E N G L I S H

E N G L I S H

Installation and User Manual

Evolution
Installation and User Manual

Revision History
Evolution Installation and User Manual, 86-81700-00 Revision: A01 ECN#: 005225 03/2007

Copyright 2007 MGE Office Protection Systems All rights reserved. Printed in U.S.A. MGE Office Protection Systems 13 Whatney, Suite #101 Irvine, CA 92618
(949) 268-2800

For Technical Support, Customer Care Center, or Customer FAQ, please visit our website: www.mgeops.com or call (800) 279-7776

86-81700-00 A01

Evolution

E N G L I S H

86-81700-00 A01

E N G L I S H

Contents

Introduction
Environmental Protection ....................................................................................................................1 IMPORTANT SAFETY INSTRUCTIONS ............................................................................................2 Certification Standards ........................................................................................................................2 Safety of Persons ..........................................................................................................................2 Product Safety ..........................................................................................................................2 Special Precautions ..........................................................................................................................2 Environment ..........................................................................................................................2 Symbol Usage ..........................................................................................................................3

Presentation
1.1 1.2 1.3 Standard Positions..........................................................................................................1 1 Rear Panels ..................................................................................................................1 2 Control Panel ..................................................................................................................1 2

Installation
2.1 2.2 2.3 2.4 2.5 2.6 Unpacking and Contents Check ....................................................................................2 Installation of Tower Model ............................................................................................2 Installation of Rack Model ..............................................................................................2 Installation of the 650 Rack Model ................................................................................2 Communication Ports ....................................................................................................2 Equipment Connections..................................................................................................2 1 2 2 3 4 5

Operation
3.1 3.2 3.3 3.4 3.5 Start-Up and Normal Operation......................................................................................3 1 Operation on Battery Power ..........................................................................................3 1 Return of AC Input Power ..............................................................................................3 1 UPS Shutdown ..............................................................................................................3 2 UPS Remote Control ......................................................................................................3 2

Access to Measurements and Personalization Data


Main-output Personalization ........................................................................................................4 Voltage-threshold Personalization ..............................................................................................4 UPS-sensitivity Personalization ..................................................................................................4 UPS ON/OFF Personalization ....................................................................................................4 Battery Personalization ................................................................................................................4 1 1 1 2 2

Maintenance
5.1 5.2 5.3 Troubleshooting ............................................................................................................5 1 Replacing the Battery Module in the Tower Model ........................................................5 1 Replacing the Battery Module in the Rack Model ..........................................................5 2

Appendices
6.1 6.2 6.3 Technical Specifications ................................................................................................A 1 Programming the Programmable Outlets ......................................................................A 2 Glossary ........................................................................................................................A 4

86-81700-00 A01

Contents

ci

Evolution

E N G L I S H

c ii

86-81700-00 A01

E N G L I S H

Installation and User Manual

Introduction
Thank you for selecting an MGE Office Protection Systems product to protect your electrical equipment. The Evolution range has been designed with the utmost care. We recommend that you take the time to read this manual to take full advantage of the many features of your UPS (Uninterruptible Power System). Warning: This is a class A UPS product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take additional measures. If the device must be installed in overvoltage category III or IV environments, additional upstream overvoltage protection must be provided for. Before installing Evolution, please read the booklet on the required safety instructions. Then follow the indications in this manual. To discover the entire range of MGE Office Protection Systems products and the options available for the Evolution range, we invite you to visit our web site at www.mgeops.com or contact your MGE Office Protection Systems representative.

Environmental Protection
MGE Office Protection Systems has implemented an environmental-protection policy. Products are developed according to an eco-design approach.

Substances
This product does not contain CFCs, HCFCs or asbestos.

Packing
To improve waste treatment and facilitate recycling, separate the various packing components. The cardboard we use comprises over 50% of recycled cardboard. Sacks and bags are made of polyethylene. 01 Packing materials are recyclable and bear the appropriate identification symbol.
PET

Material Polyethylene terephthalate High-density polyethylene Polyvinyl chloride Low-density polyethylene Polypropylene Polystyrene

Abbreviation PET HDPE PVC LDPE PP PS

Symbol number 01 02 03 04 05 06

01
PET

Follow all local regulations for the disposal of packing materials.

End of life
MGE Office Protection Systems will process products at the end of their service life in compliance with local regulations. MGE Office Protection Systems works with companies in charge of collecting and eliminating our products at the end of their service life.

Product The product is made up of recyclable materials. Dismantling and destruction must take place in compliance with all local regulations concerning waste. At the end of its service life, the product must be transported to a processing centre for electrical and electronic waste. Battery The product contains lead-acid batteries that must be processed according to applicable local regulations concerning batteries. The battery may be removed to comply with regulations and in view of correct disposal. The "Material Safety Data Sheets" (MSDS) for the batteries are available on our web site*. (*) For more information or to contact the Product Environmental manager, please visit our website: www.mgeops.com.

86-81700-00 A01

Introduction

Evolution

E N G L I S H

IMPORTANT SAFETY INSTRUCTIONS


SAVE THESE INSTRUCTIONS. This manual contains important instructions that
should be followed during installation and maintenance of the UPS and batteries. The Evolution models that are covered in this manual are intended for installation in an environment within 0 to 35 for 650-1150VA and 0 to 40 for 1550VA, free of conductive contaminant. The outlet socket shall be installed near the equipment and shall be easily accessible. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

Certification Standards

IEEE 587-1980/ANSI C62.41 1980 Standards for Surge Withstand Ability FCC rules and regulations of Part 15, Subpart B, Class A UL listed under 1778, Standards for Uninterruptible Power Supply Equipment IEC 61000-4-2 (ESD): level 4 IEC 61000-4-3 (Radiated field): level 3 IEC 61000-4-4 (EFT): level 4 IEC 61000-4-5 (surge): level 4 IEC 61000-4-6 (electromagnetic conducted field): level 3 IEC 61000-4-8 (radiated magnetic field): level 4 The system has its own power source (the battery). Consequently, the power outlets may be energized even if the systems is disconnected from the AC power source. Dangerous voltage levels are present within the system. It should be opened exclusively by qualified service personnel. The system must be properly grounded. The battery supplied with the system contains small amounts of toxic materials. To avoid accidents, the directives listed below must be observed: -Never burn the battery (risk of explosion). -Do not attempt to open the battery (the electrolyte is dangerous for the eyes and skin). -Comply with all applicable regulations for the disposal of the battery. -Batteries constitute a danger (electrical shock, burns). The short-circuit current may be very high. Precautions must be taken for all handling: remove watches, rings, bracelets and any other metal objects, use tools with insulated handles. -Do not lay tools or metal parts on top of batteries. The UPS connection instructions and operation described in the manual must be followed in the indicated order. A protection circuit breaker must be installed upstream and be easily accessible. The system can be disconnected from the AC power source by opening this circuit breaker. Check that the indications on the rating plate correspond to your AC powered system and to the actual electrical consumption of all the equipment to be connected to the system. Never install the system near liquids or in an excessively damp environment. Never let a foreign body penetrate inside the system. Never block the ventilation grates of the system. Never expose the system to direct sunlight or source of heat. If the system must be stored prior to installation, storage must be in a dry place. The admissible storage temperature range is -20C to +50C. All handling operations will require at least two people (unpacking, installation in rack system). Before and after the installation, if the UPS remains de-energized for a long period, the UPS must be energized for a period of 24 hours, at least once every 6 months (for a normal storage temperature less than 25C). This charges the battery, thus avoiding possible irreversible damage. During the replacement of the Battery Module, it is imperative to use the same type and number of element as the original Battery Module provided with the UPS to maintain an identical level of performance and safety. In case of doubt, dont hesitate to contact your MGE Office Protection Systems representative. This product has been designed to respect the environment: It does not contain any Chlorofluorocarbon (CFC) or Hydrochlorofluorocarbon (HCFC). UPS recycling at the end of service life: MGE Office Protection Systems undertakes to recycle, by certified companies and in compliance with all applicable regulations, all UPS products recovered at the end of their service life (contact your MGE Office Protection Systems branch office). Packing: UPS packing materials must be recycled in compliance with all applicable regulations. WARNING: This product contains lead-acid batteries. Lead is a dangerous substance for the environment if it is not properly recycled by specialized companies.

Safety of Persons

Product Safety

Special Precautions

Environment

Introduction

86-81700-00 A01

E N G L I S H

Installation and User Manual

Symbol Usage

Important instructions that must always be followed.

Information, advice, help.

Visual indication.

Action.

Audible signal.

LED off.

LED on

LED flashing

86-81700-00 A01

Introduction

Evolution

E N G L I S H

(This page left blank intentionally)

86-81700-00 A01

E N G L I S H

Installation and User Manual

Presentation

1.1

Standard Positions
Tower Models
Dimensions (W x H x D) in inches Evolution 650 Evolution 850 Evolution 1150 Evolution 1550 5.8 x 9.2 x 16.5 5.8 x 9.2 x 16.5 5.8 x 9.2 x 16.5 5.8 x 9.2 x 19.4

Weights in lbs Evolution 650 Evolution 850 Evolution 1150 Evolution 1550 18.8 24.5 27.2 36

Rack Models
Dimensions (W x H x D) in inches Evolution 650 Rack Evolution 850 Rack Evolution 1150 Rack Evolution 1550 Rack 17.2 x 1.7 x 14.4 17.2 x 1.7 x 20.2 17.2 x 1.7 x 20.2 17.2 x 1.7 x 21.9

Weights in lbs Evolution 650 Rack Evolution 850 Rack Evolution 1150 Rack Evolution 1550 Rack 22.7 36 37 44.3

86-81700-00 A01

Presentation

11

Evolution

E N G L I S H

1.2

Rear Panels
Evolution 650/850/1150/1550
(1) Slot for optional communication card
AC OUTPUT I max 12A

(2) Attached 6 ft. input power cord with 5-15P plug, 15A (3) 2 NEMA 5-15R for connection of equipment (4) RS232 communication port
2

Programmable

U.S. PAT. NO. 6,094,363


or
36Vdc, 9Ah
Pb

(5) 2 NEMA 5-15R programmable outlets


R

RS232

(6) USB communication port


a

1
ROO RPO

55K6 U.P.S.

AC INPUT

(7) Connector for remote RPO/ROO (Remote Power OFF / Remote ON/OFF) (a) LED indicating site wiring fault alarm with reset button

Evolution 650/850/1150/1550 Rack


Evolution 650/850/1150 Rack
Programmable 1 2
55K6 (E87247)

SITE WIRING FAULT

AC INPUT

Pb
AC OUTPUT

RS232

or

RPO ROO

Site wiring fault

Evolution 1550 Rack


36Vdc, 9Ah
Pb

AC OUTPUT I max 12A


U.S. PAT. No. 6,094,363
R

Programmable

AC INPUT

AC Input Volt 120V~1O Amps 12A MAX Hertz 50/60 Hz AC Output Volt 100/120/127V~1O Amps 12.96/12/11.34A Hertz 50/60 Hz W/VA 1100W/1440VA

RS232

or

RPO ROO

55K6 U.P.S.

SITE WIRING FAULT

1.3

Control Panel
(8) Bargraph indicating the percent load (9) Programmable outlet 1 is supplied (10) ON/OFF button for UPS and outlets (11) Bargraph indicating battery-charge level (12) Programmable outlet 2 is supplied (13) Load protected LED (14) Downgraded operation LED (15) Load not protected LED

Bargraphs (8) and (11)

12

Presentation

86-81700-00 A01

E N G L I S H

Installation

2.1

Unpacking and Contents Check

(16) Evolution UPS, tower or rack model with input cable attached (18) Documentation (19) Solution-Pac CD-ROM

(20) RS232 communication cable (21) USB communication cable (22) Mounting kit for 19-inch bays (rack model only)

Packing materials must be disposed of in compliance with all local regulations concerning waste. Recycling symbols are printed on the packing materials to facilitate sorting.

86-81700-00 A01

Installation

21

Evolution

E N G L I S H

2.2

Installation of Tower Model

2.3

Installation of Rack Model


Follow steps 1 to 4 for module mounting on the rails.

The rails and necessary hardware are supplied by MGE Office Protection Systems.

22

Installation

86-81700-00 A01

E N G L I S H

Installation and User Manual

2.4

Installation of the 650 Rack Model


Follow steps 1 to 3 for rack mounting.

Wall mounting

The necessary hardware is supplied by MGE Office Protection Systems.

86-81700-00 A01

Installation

23

Evolution

E N G L I S H

2.5

Communication Ports
Connection of RS232 or USB communication port (optional)
The RS232 and USB communication ports cannot operate simultaneously. 1. Connect the RS232 (20) or USB (21) communication cable to the serial or USB port on the computer equipment.
U.S. PAT. NO. 6,094,363
36Vdc, 9Ah
Pb
R

AC OUTPUT I max 12A

Programmable

or

RS232

55K6 U.P.S.

AC INPUT

SITE WIRING FAULT

2. Connect the other end of the communication cable (20) or (21) to the USB (6) or RS232 (4) communication port on the UPS. The UPS can now communicate with MGE Office Protection Systems power management software.

Installation of the communication cards (optional)


It is not necessary to shutdown the UPS before installing a communication card.
AC OUTPUT I max 12A

ROO RPO

Limited-access slot for the communication card

1. Remove the slot cover (1) secured by screws. 2. Insert the communication card in the slot. 3. Secure the card cover with the two screws.

Programmable

RS232

U.S. PAT. NO. 6,094,363

or

36Vdc, 9Ah
Pb

55K6 U.P.S.

ROO RPO

Characteristics of the contact communication port (optional)


AC INPUT

SITE WIRING FAULT

Pin Pin Pin Pin Pin Pin Pin Pin Pin

1: 2: 3: 4: 5: 6: 7: 8: 9:

Not used Battery fault UPS power off Load on Utility COMMON Load on bypass, when available on UPS Low battery UPS on, load powered Load on battery

n.o.: normally open contact When a signal is activated, the contact is closed between the common (pin 5) and the pin for the corresponding signal. Please refer to the Network Management Card User Manual for the latest characteristics information. Contact characteristics (optocoupler) Voltage: 48 V DC max Current: 25 mA max Power: 1.2 W

24

Installation

86-81700-00 A01

E N G L I S H

Installation and User Manual

2.6

Equipment Connections
Check that the indications on the name plate located on the back of the UPS correspond to the AC-power source and the true electrical consumption of the total load. 1. 2. Connect the input power cord to the AC outlet receptacle. Connect the loads to the UPS outlets as shown. It is preferable to connect the priority loads to the two outlets marked (3) and the nonpriority loads to the two programmable outlets marked (5).

To program shutdown of outlets (5) during operation on battery power and thus optimize the available backup time, the MGE Office Protection Systems communication software is required. Evolution 650/850/1150 Evolution 1550

AC OUTPUT I max 12A

3
3
2

5
5
Load
AC INPUT

Programmable

RS232

U.S. PAT. NO. 6,094,363

or

36Vdc, 9Ah
Pb

Load
R

55K6 U.P.S.

ROO RPO

Evolution 650/850/1150 Rack


Load
Programmable 1 2
55K6 (E87247)

AC INPUT

Pb
AC OUTPUT

RS232

or

RPO ROO

Site wiring fault

Evolution 1550 Rack

SITE WIRING FAULT

Load
36Vdc, 9Ah
Pb

AC OUTPUT I max 12A


U.S. PAT. No. 6,094,363
R

Programmable

AC INPUT

AC Input Volt 120V~1O Amps 12A MAX Hertz 50/60 Hz AC Output Volt 100/120/127V~1O Amps 12.96/12/11.34A Hertz 50/60 Hz W/VA 1100W/1440VA

RS232

or

RPO ROO

55K6 U.P.S.

SITE WIRING FAULT

86-81700-00 A01

Installation

25

Evolution

E N G L I S H

(This page left blank intentionally)

26

Installation

86-81700-00 A01

E N G L I S H

Operation
3.1 Start-Up and Normal Operation
Press button (10) for approximately 1 second. The buzzer beeps once and all the LEDs go ON simultaneously. If AC input power is available, button (10) and LED (13) are ON. The load is supplied by the AC-power source. Conditions permitting, the UPS runs a battery test, indicated by LEDs (11) and the buzzer. If AC input power is not available, button (10) and LEDs (13) and (14) are ON. The load is supplied by the UPS on battery power.

The connected devices are protected by the UPS. If LED (15) is ON, a fault has occurred (see the "Troubleshooting" section).

3.2

Operation on Battery Power


Transfer to battery power
The connected devices continue to be protected by the UPS when AC input power is no longer available. The necessary energy is provided by the battery. Button (10) and LEDs (13) and (14) are ON. The audio alarm beeps every ten seconds.

The connected devices are supplied by the battery.

Low-battery warning
Button (10) and LEDs (13) and (14) are ON. The audio alarm beeps every three seconds.

The remaining battery power is low. Shut down all applications on the connected equipment because automatic UPS shutdown is imminent.

End of battery backup time


All the LEDs go OFF. The audio alarms stops.

The UPS is completely shut down.

3.3

Return of AC Input Power


Following an outage, the UPS restarts automatically when AC input power returns (unless the restart function has been disabled via UPS personalization) and the load is again supplied.

86-81700-00 A01

Operation

31

Evolution

E N G L I S H

3.4

UPS Shutdown
Press button (10) for approximately 2 seconds. The devices connected to the UPS are no longer supplied.

3.5

UPS Remote Control


Evolution offers a choice between two remote control functions.
AC OUTPUT I max 12A

RPO (Remote Power OFF) allows a remote contact to be used to disconnect all the equipment connected to the UPS. Restarting the UPS requires manual intervention. ROO (Remote ON/OFF) allows remote action of button (10) to shut down the UPS.

2
RS232

U.S. PAT. NO. 6,094,363


36Vdc, 9Ah
Pb
R

Programmable

or

7
AC INPUT

1
ROO RPO

55K6 U.P.S.

These functions are obtained by opening of the contact connected between the appropriate pins of connector (7) on the rear panel of the UPS (see figures below).

Remote control connection and test


1. Check that the UPS is OFF and disconnected from the AC input source. 2. Remove connector (7) after unscrewing the screws. 3. Connect a normally closed volt-free contact (60 V DC / 30 V AC max., 20 mA max., 0.75 mm2 cable cross-section) between the two pins of connector (7) (see diagram). Contact open: UPS shutdown Contact closed: UPS start-up (UPS connected to AC power and AC power is available) Note: The local ON/OFF control using button (10) overrides the remote-control function. Contact open: UPS shutdown, LED (14) goes ON To return to normal operation, deactivate the remote external contact (LED (14) goes OFF) and restart the UPS by pressing button (10) 4. 5. 6. Plug connector (7) into the back of the UPS. Connect and restart the UPS following the previously described procedures. Activate the external remote shutdown contact to test the function.

Warning: This connector must only be connected to SELV (Safety Extra-Low Voltage) circuits.

32

SITE WIRING FAULT

Operation

86-81700-00 A01

E N G L I S H

Access to Measurements and Personalization Data

Insert the Solution-Pac CD-ROM in the drive. On the first navigation screen, select "Point to Point solution" and follow the instructions on how to install the Personal Solution-Pac software. Then select "Settings", "Advanced settings" and "UPS settings".

Note that the Linux/Unix/MacOS versions of Personal Solution-Pac software do not offer this possibility. It is possible to modify the settings listed below (detailed comments are available in the Personal SolutionPac software).

Main-output personalization
Function Output voltage on battery power Overload alarm threshold Factory Setting 120 Volts AC 105% Other available settings
100/120/127 Volts AC

30/50/70%

Voltage-threshold personalization
Function Factory Setting Other available settings 141 to 153 Volts AC 80 to 94 Volts AC 127 to 138 Volts AC 92 to 108 Volts AC Enabled

High threshold for transfer to battery 151 Volts AC +3% Low threshold for transfer to battery 89 Volts AC +3% Fader activation threshold Booster activation threshold Maximum input-voltage range 132 Volts AC +3% 102 Volts AC +3% Disabled

UPS-sensitivity personalization
Function UPS-sensitivity level Factory Setting Normal Other available settings
High or low

86-81700-00 A01

Access to Measurements and Personalization Data

41

Evolution

E N G L I S H

UPS ON/OFF personalization


Function Automatic start Cold start Forced shutdown Energy-savings mode UPS ON/OFF controlled by software Battery level before restart Factory Setting Enabled Enabled Enabled Disabled Enabled 0% Other available settings
Disabled

Disabled Disabled Enabled Disabled 0 to 100%

Battery personalization
Function Battery-test intervals Low-battery warning Battery protection against deep discharge Audio alarm Factory Setting Weekly 20% Enabled Enabled Other available settings No test / daily test / monthly test 0 to 100% Disabled Disabled

42

Access to Measurements and Personalization Data

86-81700-00 A01

E N G L I S H

Maintenance
5.1 Troubleshooting
Indication When the UPS is started using button (10), all the LEDs go ON once and the buzzer beeps once, then LED (14) remains ON. Diagnostic The remote power off (RPO) contact has been activated to shut down the UPS and now prevents restart. Correction Set the contact back to its normal position and press button (24) to restart.

The percent load is greater than the Button (10) and LEDs (13) set overload level or UPS capacity. and (14) are ON and all the LEDs on bargraph (8) flash. A critical overload has occurred on Button (10) and LED (15) the UPS output. If AC input power are ON and all the LEDs on fails, the load will not be supplied in bargraph (8) are flashing. battery mode. LED (15) is ON and all the LEDs on bargraph (11) are flashing. LED (15) alone is ON and the buzzer sounds continuously. A battery fault has been detected during the automatic test.

Check the power drawn by the connected devices and disconnect any non-priority devices. Check the overload level setting.

Check the power drawn by the connected devices and disconnect any non-priority devices.

Replace the battery module (See Section 5.2, Battery-module replacement).

A UPS internal fault has occurred and Visit www.mgeops.com for after-sales support or call the load is not supplied. (800) 279-7776.

5.2

Replacing the Battery Module in the Tower Model


Safety recommendations
See Section 5.3 on Page 52 for safety recommendations.

Battery-module removal
The UPS must be turned as shown in the figure opposite. A. Remove the two screws on the left-hand side.

B. Lift and pull away the panel with the logo.

C. Pull on the two connectors to disconnect the battery (never pull on the wires). D. Pull the plastic tab to remove the battery.

86-81700-00 A01

Maintenance

51

Evolution

E N G L I S H

Mounting the new battery module


Carry out the above instructions in reverse order. To ensure safety and high performance, use only batteries supplied by MGE Office Protection Systems. Take care to firmly press together the two parts of the connector during remounting.

5.3

Replacing the Battery Module in the Rack Model


Safety recommendations
The battery can cause electrocution and high short-circuit currents. The following safety precautions are required before servicing the battery components: CAUTION: Do not dispose of batteries in a fire. The batteries may explode. Dispose of used batteries according to the instructions. CAUTION: Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes. It may be toxic. CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries: a. b. c. d. e. f. Remove watches, rings, or other metal objects. Use tools with insulated handles. Wear rubber gloves and boots. Do not lay tools or metal parts on top of batteries. Disconnect charging source prior to connecting or disconnecting battery terminals. Determine if battery is inadvertently grounded. If inadvertently grounded, remove source from ground. Contact with any part of a grounded battery can result in electrical shock. The likelihood of such shock can be reduced if such grounds are removed during installation and maintenance.

Battery-module removal
A. Remove the two screws on the left-hand side of the front panel.

B. Disconnect the battery block by separating the two connectors (never pull on the wires).

52

Maintenance

86-81700-00 A01

E N G L I S H

Installation and User Manual

C. Remove the part.

D. Pull the plastic tab to remove the battery block and replace it.

Mounting the new battery module


Carry out the above instructions in reverse order. To ensure safety and high performance, use only batteries supplied by MGE Office Protection Systems. Take care to firmly press together the two parts of the connector during remounting.

86-81700-00 A01

Maintenance

53

Evolution

E N G L I S H

(This page left blank intentionally)

54

Maintenance

86-81700-00 A01

E N G L I S H

Appendices

6.1 Technical specifications

Evolution

650 / 650 Rack

850 / 850 Rack

1150 / 1150 Rack

1550 / 1550 Rack

Output power

650 VA / 420 W

850 VA / 600 W

1150 VA / 770 W

1550 VA / 1100 W

AC input power Rated input voltage Input-voltage range 50 Hz input-frequency range 60 Hz input-frequency range

Single phase 120 V 89 V to 151 V (1) 47 Hz to 70 Hz (2) 56.5 Hz to 70 Hz (2)

Output on battery power Voltage Frequency

120 V (+6% / -10%)(3) 50/60 Hz 0.1 Hz

Battery (sealed lead acid, maintenance free) Tower model Rack model Environment Operating temperature range Storaage temperature range Humidity Noise Level

1 x 12 V -9 Ah 2 x 6 V -9 Ah

2 x 12 V -7.2 Ah 4 x 6 V -7.2 Ah

2 x 12 V -9 Ah 4 x 6 V -9 Ah

3 x 12 V -9 Ah 6 x 6 V -9 Ah

0 to 35C -20C to 50C 20 to 90% (without condensation) < 40 dbA

0 to 40C

(1) The high and low thresholds can be adjusted using Personal Solution-Pac software. (2) Up to 40 Hz in extended frequency mode (programmable using Personal Solution-Pac software). (3) Adjustable to 100 V (10% derating of output power) / 120 V / 127 V. This product is designed for IT power distribution system.

86-81700-00 A01

Appendices

A1

Evolution

E N G L I S H

6.2

Programming the Programmable Outlets


1. To open the Setting window, left-click on Start Menu / Programs / MGE UPS Systems / Personal Solution Pac / Settings, or right-click on the PSP power plug located in the SYS Tray. Click on the + symbol next to UPS Settings to expand the UPS Settings section.

2.

3.

Click on Startup Timer and change the The group of outlets restarts after to 0 to have powershare outlet provide power at the same time the as main outlets.

A2

Appendices

86-81700-00 A01

E N G L I S H

Installation and User Manual

4. 5.

Repeat step 3 for each programmable outlet. After making the changes,s click on the Apply button.

The section entitled Shutdown timer allows the user to define how long the powershare outlet should provide power after a power loss. To configure the powershare to power off at the same time as the main outlets: 6. Set the The group of outlet is powered OFF after to 65535.

86-81700-00 A01

Appendices

A3

Evolution

E N G L I S H

6.3

Glossary
Backup time Battery test Booster mode Time during which the load can be supplied by the UPS operating on battery power. Internal UPS test to check battery status. Automatic UPS mode that steps up the AC voltage if it is too low, to a level above the personalised set-point, without discharging the battery. The devices connected to the UPS can be started even if AC input power is not available. The UPS operates on battery power alone. Battery discharge beyond the permissible limit, resulting in irreversible damage to the battery. Automatic UPS mode that steps down the AC voltage if it is too high, to a level below the personalised set-point, without discharging the battery. Devices or equipment connected to the UPS output. This is a battery-voltage level indicating that battery power is low and that the user must take action in light of the imminent break in the supply of power to the load. The AC-power line supplying the UPS under normal conditions. Ratio of the power effectively drawn by the load to the maximum output of the UPS. It is possible to modify certain UPS parameters set in the factory. Certain UPS functions can also be modified by the Personal Solution-Pac software to better suit user needs. Controllable outlets for automatic load shedding, remote shutdown and sequential restart (personalised using Personal Solution-Pac software. Uninterruptible Power System. This function enables or disables initiation of UPS ON/OFF control sequences by computer power-management software.

Cold start

Deep discharge Fader mode

Load Low-battery warning

Normal AC input Percent load Personalization

Programmable outlets UPS UPS ON/OFF controlled by software

A4

Chaptername

86-81700-00 A01

F R A N A I S

Manuel dinstallation et dutilisation

Evolution
Manuel dinstallation et dutilisation

Historique des rvisions


Evolution Manuel dinstallation et dutilisation, 86-81700-00 Rvision : A01 N NCE : 005225 03/2007

Copyright 2007 MGE Office Protection Systems All rights reserved. Printed in U.S.A. MGE Office Protection Systems 13 Whatney, Suite #101 Irvine, CA 92618 (949) 268-2800 For Technical Support, Customer Care Center, or Customer FAQ, please visit our website: www.mgeops.com or call (800) 279-7776

86-81700-00 A01

Evolution

F R A N A I S

86-81700-00 A01

F R A N A I S

Table des matires

Introduction
Protection environnementale ..............................................................................................................1 DIRECTIVES IMPORTANTES SUR LA SCURIT ..........................................................................2 Normes de certification........................................................................................................................2 Scurit des personnes ......................................................................................................................2 Scurit du produit ..............................................................................................................................2 Prcautions spciales..........................................................................................................................2 Environnement ....................................................................................................................................2 Symboles utiliss ................................................................................................................................3

Prsentation
1.1 1.2 1.3 Positions standard ..........................................................................................................1 1 Panneaux arrire ............................................................................................................1 2 Panneau de commande ................................................................................................1 2

Installation
2.1 2.2 2.3 2.4 2.5 2.6 Dballage et vrification du contenu ..............................................................................2 Installation du modle tour ............................................................................................2 Installation du modle rack ............................................................................................2 Installation du modle rack 650......................................................................................2 Ports de communication ................................................................................................2 Connexion dquipement ................................................................................................2 1 2 2 3 4 5

Fonctionnement
3.1 3.2 3.3 3.4 3.5 Dmarrage et fonctionnement normal ............................................................................3 fonctionnement sur batterie ............................................................................................3 Retour du rseau lectrique ..........................................................................................3 Mise hors service de lUPS ............................................................................................3 Commande distance de lUPS ....................................................................................3 1 1 1 2 2

Accs aux mesures et aux donnes de personnalisation


Personnalisation Personnalisation Personnalisation Personnalisation Personnalisation des des des des des options options options options options de sortie principale ......................................................................4 1 du seuil de tension ......................................................................4 1 de sensibilit de lUPS..................................................................4 1 de mise en marche/arrt de lUPS ..............................................4 2 batterie..........................................................................................4 2

Entretien
5.1 5.2 5.3 5.4 Dpannage ....................................................................................................................5 Remplacement du module batterie dans le modle tour................................................5 Remplacement du module batterie dans le modle rack ..............................................5 Centre de formation........................................................................................................5 1 1 2 4

Annexes
6.1 6.2 Caractristiques techniques ..........................................................................................A 1 Glossaire ........................................................................................................................A 2

86-81700-00 A01

Table des matires

ci

Evolution

F R A N A I S

(This page left blank intentionally)

c ii

86-81700-00 A01

F R A N A I S

Introduction
Merci davoir choisi un produit de MGE Office Protection Systems pour protger votre quipement lectrique. Les produits de la gamme Evolution on t conus avec le plus grand soin. Nous vous recommandons de lire attentivement le prsent manuel afin de profiter pleinement de toutes les caractristiques de votre UPS (systme dalimentation sans coupure). Avertissement : Il sagit dun produit UPS de classe A. Dans un environnement rsidentiel, ce produit peut causer de linterfrence radio. Le cas chant, lutilisateur pourrait devoir prendre des mesures additionnelles. Si vous installez lappareil dans un environnement de surtension de catgorie III ou IV, vous devez galement prvoir une protection supplmentaire contre les surtensions en amont. Avant dinstaller votre UPS Evolution, veuillez lire la brochure sur les instructions de scurit obligatoires. Suivez ensuite les indications dans le prsent manuel. Pour connatre tous les produits de MGE Office Protection Systems, ainsi que les options offertes pour la gamme Evolution, nous vous invitons consulter notre site Web sur www.mgeops.com ou communiquer avec votre reprsentant de MGE Office Protection Systems.

Protection environnementale
MGE Office Protection Systems a mis en uvre une politique de protection environnementale. Nos produits sont conus en adoptant une approche cologique.

Substances
Ce produit ne contient pas de CFC, de HCFC ou damiante.

Emballage
Pour amliorer le traitement des dchets et faciliter le recyclage, triez les divers matriaux demballage. Le carton utilis est compos 50 % de carton recycl. Les sacs sont faits de polythylne. 01 Les matriaux demballages sont recyclables et affichent le symbole didentification appropri.
PET

Matriau Polytrphalate d'thylne Polythylne haute densit Polychlorure de vinyle Polythylne basse densit Polypropylne Polystyrne

Abrviation PTE PEHD PVC PEBD PP PS

Numro de symbole 01 02 03 04 05 06

01
PET

Au moment dliminer les matriaux demballage, respectez les rglements locaux.

Fin de vie
MGE Office Protection Systems traitera les produits en fin de vie de service conformment aux rglements locaux. MGE Office Protection Systems collabore avec les entreprises responsables de recueillir et dliminer nos produits en fin de vie de service.

Produit Le produit est compos de matriaux recyclables. Son dmantlement et sa destruction doivent se faire en accord avec les rglementations locales en vigueur concernant les dchets. Le produit en fin de vie doit tre dpos dans un centre de traitement des dchets lectriques et lectroniques. Batterie Le produit contient des batteries au plomb qui doivent tre traites suivant les rglementations locales en vigueur concernant les batteries. Pour suivre ces rglementations et liminer la batterie de manire propre, il est possible de lextraire du produit. Les fiches de donnes de scurit ou "Material Safety Data Sheet" (MSDS) des batteries sont disponibles sur notre site web*. (*) Pour obtenir de plus amples renseignements ou pour communiquer avec le directeur de la politique environnementale du produit, utilisez le formulaire environnemental dans notre site : www.mgeops.com.

86-81700-00 A01

Introduction

Evolution

F R A N A I S

DIRECTIVES IMPORTANTES SUR LA SCURIT


CONSERVEZ CES INSTRUCTIONS. Le prsent manuel contient des instructions importantes quil faut suivre durant linstallation et lentretien de lUPS et des batteries.
Les modles de la gamme Evolution mentionns dans le prsent manuel sont conus pour un environnement ayant une temprature ambiante entre 0 et 40 C, exempt de contaminants conducteurs. Cet quipement a fait lobjet dessais et a t dclar conforme aux limites des dispositifs numriques de classe A, conformment la partie 15 des rglements de la FCC. Ces limites ont t tablies pour offrir une protection raisonnable contre linterfrence nuisible lorsque lquipement est utilis dans un environnement commercial. Cet quipement gnre, utilise et met de lnergie RF et, sil nest pas install et utilis conformment au manuel dinstruction, peut causer des interfrences nuisibles aux communications radio. Lutilisation de cet quipement dans une zone rsidentielle pourrait causer des interfrences nuisibles. Le cas chant, lutilisateur devra corriger le problme dinterfrence ses frais.

Normes de certification

Normes de rsistance aux surtensions IEEE 587-1980/ANSI C62.41 1980 Rgles et rglements du FCC de la partie 15, sous-partie B, classe A Liste de lUL 1778, normes en matire dquipement dalimentation sans coupure IEC 61000-4-2 (DES) : niveau 4 IEC 61000-4-3 (champ de rayonnement) : niveau 3 IEC 61000-4-4 (transitoires lectriques rapides) : niveau 4 IEC 61000-4-5 (transitoires rapides) : niveau 4 IEC 61000-4-6 (champ lectromagntique) IEC 61000-4-8 (champ magntique par conduction) Le systme est muni de sa propre source dalimentation (la batterie). Les prises dalimentation peuvent donc tre nergises mme si le systme nest pas branch une source dalimentation c.a. Le systme comporte des niveaux de tension dangereux. Pour cette raison, seul le personnel qualifi peut louvrir. Le systme doit tre mis la terre correctement. La batterie fournie avec le systme contient de petites quantits de matires toxiques. Pour viter les accidents, respectez les directives suivantes: -Ne brlez jamais la batterie (elle risque dexploser). -Nessayez pas douvrir la batterie (llectrolyte est dangereux pour les yeux et la peau). -Respectez tous les rglements applicables au moment dliminer la batterie. -La batterie constitue un danger (choc lectrique, brlure). Le courant en court-circuit peut tre trs lev. Prenez donc les prcautions suivantes pour toutes les manipulations : enlevez montre, bagues, bracelets et tout autre objet mtallique; utilisez des outils munis de poignes isoles. -Ne placez pas doutils ou de pices en mtal sur la batterie. Suivez les instructions de branchement et dutilisation de lUPS dans lordre indiqu dans le manuel. Il faut installer un disjoncteur de protection facilement accessible en amont. Il est possible de couper lalimentation c.a. du systme par le disjoncteur. Assurez-vous que les indications de la plaque signaltique correspondent votre systme aliment par une source c.a. et la consommation lectrique de tout lquipement raccorder au systme. Ninstallez jamais le systme prs de liquide ou dans un environnement excessivement humide. Ne laissez jamais un corps tranger entrer dans le systme. Ne bloquez jamais les grilles de ventilation du systme. Nexposez jamais le systme la lumire directe du soleil ou une source de chaleur. Si vous devez entreposer le systme avant de lutiliser, entreposez-le dans un endroit sec. La plage de tempratures appropries pour lentreposage du systme est de -20 C +50 C. Toute les manipulations requirent au moins deux personnes (dballage, installation dans un bti). Avant et aprs linstallation, si lUPS demeure hors-tension pendant une longue priode, mettez-le sous tension pendant 24 heures au moins une fois tous les six mois ( une temprature dentreposage normale de moins de 25 C). Vous chargez ainsi la batterie et vitez des dommages irrparables. Durant le remplacement de la batterie, il est essentiel dutiliser le mme type et le mme nombre dlments que la batterie originale, fournie avec lUPS, afin dobtenir le mme niveau de rendement et de scurit. En cas de doute, nhsitez pas communiquer avec votre reprsentant MGE Office Protection Systems. Ce produit a t conu pour respecter lenvironnement : Il ne contient aucun Chlorofluorocarbone (CFC) ou Hydrochlorofluorocarbone (HCFC). Recyclage de lUPS la fin de sa vie de service : MGE Office Protection Systems sengage recycler, par lentremise dentreprises certifies et conformment tous les rglements, tous les produits dUPS rcuprs la fin de leur vie de service (communiquez avec votre succursale de MGE Office Protection Systems). Emballage : Il faut recycler les matriaux demballage des UPS conformment tous les rglements applicables. AVERTISSEMENT : Ce produit contient une batterie au plomb. Le plomb est une substance nocive pour lenvironnement sil nest pas recycl correctement par des entreprises spcialises.

Scurit des personnes


Scurit du produit

Prcautions spciales

Environnement

Introduction

86-81700-00 A01

F R A N A I S

Manuel dinstallation et dutilisation

Symboles utiliss

Instructions importantes quil faut toujours suivre.

Information, conseil, aide.

Aide visuel.

Action.

Signal sonore.

Voyant teint.

Voyant allum.

Voyant clignotant.

86-81700-00 A01

Introduction

Evolution

F R A N A I S

(This page left blank intentionally)

86-81700-00 A01

F R A N A I S

Prsentation

1.1

Positions standard
Modles tour

Dimensions (L x H x P) en pouces Evolution 650 Evolution 850 Evolution 1150 Evolution 1550 5,8 x 9,2 x 16,5 5,8 x 9,2 x 16,5 5,8 x 9,2 x 16,5 5,8 x 9,2 x 19,4

Poids en livres Evolution 650 Evolution 850 Evolution 1150 Evolution 1550 18,8 24,5 27,2 36

Modles rack
Dimensions (L x H x P) en pouces Evolution 650 rack Evolution 850 rack Evolution 1150 rack Evolution 1550 rack 17,2 x 1,7 x 14,4 17,2 x 1,7 x 20,2 17,2 x 1,7 x 20,2 17,2 x 1,7 x 21,9

Poids en livres Evolution 650 rack Evolution 850 rack Evolution 1150 rack Evolution 1550 rack 22,7 36 37 44,3

86-81700-00 A01

Prsentation

11

Evolution

F R A N A I S

1.2

Panneaux arrire
Evolution 650/850/1150/1550
(1) Emplacement pour carte de communication optionnelle (2) Cordon dalimentation fixe de 1,83 m (6 pi) prise 5-15P, 15 A
AC OUTPUT I max 12A

(3) 2 prises NEMA 5-15R pour le branchement dquipements (4) Port de communication RS232
2
RS232

(5) 2 prises NEMA 5-15R programmables


U.S. PAT. NO. 6,094,363
36Vdc, 9Ah
Pb

Programmable

(6) Port de communication USB (7) Connecteur RPO/ROO pour le raccordement dune commande Marche/Arrt ou Arrt distance (a) Voyant indiquant un problme de filage et bouton de rinitialisation

or

1
ROO RPO

55K6 U.P.S.

SITE WIRING FAULT

AC INPUT

Evolution 650/850/1150/1550 rack


Evolution 650/850/1150 rack
Programmable 1 2
55K6 (E87247)

AC INPUT

Pb
AC OUTPUT

RS232

or

RPO ROO

Site wiring fault

Evolution 1550 rack


36Vdc, 9Ah
Pb

AC OUTPUT I max 12A


U.S. PAT. No. 6,094,363
R

Programmable

AC INPUT

AC Input Volt 120V~1O Amps 12A MAX Hertz 50/60 Hz AC Output Volt 100/120/127V~1O Amps 12.96/12/11.34A Hertz 50/60 Hz W/VA 1100W/1440VA

RS232

or

RPO ROO

55K6 U.P.S.

SITE WIRING FAULT

1.3

Panneau de commande

(8) Graphique barres indiquant le niveau de puissance utilis en sortie (9) Prise programmable 1 alimente (10) Bouton Marche /Arrt de lUPS et des prises (11) Graphique barres indiquant le niveau de charge de la batterie (12) Prise programmable 2 alimente (13) Voyant de charge protge (14) Voyant de fonctionnement dgrad (15) Voyant de charge non protge

Graphiques barres (8) et (11)

12

Prsentation

86-81700-00 A01

F R A N A I S

Manuel dinstallation et dutilisation

Installation

2.1

Dballage et vrification du contenu

(16) UPS Evolution, tour ou rack, avec cordon dalimentation fixe (18) Documentation (19) CD-ROM Solution-Pac

(20) Cble de communication RS232 (21) Cble de communication USB (22) Trousse de montage pour les btis de 19 pouces (modle modulaire seulement)

Il faut liminer les matriaux demballage conformment tous les rglements locaux sur les dchets. Les symboles de recyclage sont imprims sur les matriaux d'emballage pour en faciliter le triage.

86-81700-00 A01

Installation

21

Evolution

E N G L I S H

22

Chaptername

86-81700-00 A01

Evolution

F R A N A I S

2.2

Installation du modle tour

2.3

Installation du modle rack


Suivez les tapes 1 4 pour installer le module sur des rails.

Les rails et le ncessaire de montage sont fournis par MGE Office Protection Systems.

23

Installation

86-81700-00 A01

F R A N A I S

Manuel dinstallation et dutilisation

2.4

Installation du modle rack 650


Suivez les tapes 1 3 pour linstaller dans un rack.

Montage au mur

Le ncessaire de montage est fournie par MGE Office Protection Systems.

86-81700-00 A01

Installation

24

Evolution

F R A N A I S

2.5

Ports de communication
Raccordement du port de communication RS232 ou USB (facultatif)
Les ports de communication RS232 et USB ne peuvent pas fonctionner simultanment. 1. Branchez le cble de communication RS232 (20) ou USB (21) dans le port srie ou USB de lordinateur.
U.S. PAT. NO. 6,094,363
36Vdc, 9Ah
Pb
R

AC OUTPUT I max 12A

Programmable

or

RS232

55K6 U.P.S.

AC INPUT

SITE WIRING FAULT

2. Branchez lautre extrmit du cble de communication (20) ou (21) dans le port de communication USB (6) ou RS232 (4) de lUPS. LUPS peut maintenant communiquer avec le logiciel de gestion de lalimentation de MGE Office Protection Systems.

Installation des cartes de communication (facultatives)

ROO RPO

emplacement accs limit pour la carte de communication

Il nest pas ncessaire de mettre lUPS hors tension avant dinsrer une carte de communication. 1. Enlevez le cache maintenu en place par des vis. 2. Insrez la carte de communication dans la emplacement. 3. Fixez le couvercle de la carte laide de deux vis.

Diagramme du port de communication (facultatif)


Broches 1, 2, 3, 5, 6 : non utilises Broche 4: Commun (utilisateur) Broche 7: Batterie faible Broche 8: UPS sous tension, quipement aliment Broche 9: Fonctionnement sur batterie

n.o.: contact normalement ouvert Lorsquun signal est activ, le contact est coup entre le signal commun (broche 4) et la broche du signal correspondant. Diagramme des contacts (optocoupleur) Tension: Max de 48 V c.c. Courant: Max de 25 mA Puissance: 1,2 W

25

Installation

86-81700-00 A01

F R A N A I S

Manuel dinstallation et dutilisation

2.6

Connexion dquipement
Vrifier que les indications portes sur la plaque d'identification situe l'arrire de l'appareil correspondent aurseau lectrique d'alimentation et la consommation lectrique relle des quipements. 1. 2. Branchez le cordon dalimentation dans une prise de courant c.a. Branchez les charges dans les prises de lUPS, comme il est indiqu. Il est prfrable de brancher les charges prioritaires dans les deux prises (3) et les charges non prioritaires, dans les prises (5).

Vous devez utiliser le logiciel de communication de MGE Office Protection Systems pour programmer la mise hors-tension des prises (5) durant le fonctionnement en mode batterie afin doptimiser la dure autonomie du systme. Evolution 650/850/1150 Evolution 1550

AC OUTPUT I max 12A

3
3
2

5
5
Load
AC INPUT

Programmable

RS232

U.S. PAT. NO. 6,094,363

or

36Vdc, 9Ah
Pb

Load
R

55K6 U.P.S.

ROO RPO

Evolution 650/850/1150 rack


Load
Programmable 1 2
55K6 (E87247)

AC INPUT

Pb
AC OUTPUT

RS232

or

RPO ROO

Site wiring fault

Evolution 1550 rack

SITE WIRING FAULT

Load
36Vdc, 9Ah
Pb

AC OUTPUT I max 12A


U.S. PAT. No. 6,094,363
R

Programmable

AC INPUT

AC Input Volt 120V~1O Amps 12A MAX Hertz 50/60 Hz AC Output Volt 100/120/127V~1O Amps 12.96/12/11.34A Hertz 50/60 Hz W/VA 1100W/1440VA

RS232

or

RPO ROO

55K6 U.P.S.

SITE WIRING FAULT

86-81700-00 A01

Installation

26

Evolution

F R A N A I S

(Page laisse vierge volontairement)

27

Installation

86-81700-00 A01

F R A N A I S

Fonctionnement
3.1 Dmarrage et fonctionnement normal
Appuyez sur le bouton (10) pendant environ 1 seconde. Lindicateur sonore met un bip et tous les voyants s'allument simultanment. Si lalimentation c.a. est fonctionnelle, le bouton (10) et le voyant (13) sont allums. La charge est alimente par lalimentation c.a. Si les conditions le permettent, lUPS effectue une vrification de la batterie, indiqu par le voyant (11) et lindicateur sonore. Si lalimentation c.a. nest pas fonctionnelle, le bouton (10) et les voyants (13) et (14) sont allums. La charge est alimente par la batterie de lUPS.

Les dispositifs branchs sont protgs par l'UPS. Si le voyant (15) est allum, une faute sest produite (voir la section Dpannage ).

3.2

Fonctionnement avec alimentation par batterie


Passage sur batterie par batterie
Les dispositifs branchs demeurent protgs par lUPS lorsque lalimentation c.a. nest plus fonctionnelle. Lnergie ncessaire est fournie par la batterie. Le bouton (10) et les voyants (13) et (14) sont allums. Lavertisseur sonore met un bip toutes les dix secondes.

Les dispositifs branchs sont aliments par la batterie.

Avertissement de batterie faible


Le bouton (10) et les voyants (13) et (14) sont allums. Lavertisseur sonore met un bip toutes les trois secondes.

La charge de la batterie est faible. Fermez tous les dispositifs branchs dans lUPS, car celui-ci sera bientt hors-fonction.

Fin d'autonomie batterie


Tous les voyants steignent. Lavertisseur sonore sarrte.

LUPS est entirement hors tension.

3.3

Retour du rseau lectrique


la suite dune panne, lUPS redmarre automatiquement lorsque le rseau lectrique d'alimentation fonctionne de nouveau ( moins que la fonction de redmarrage automatique a t dsactive en personnalisant les options de lUPS); la charge est alors nouveau alimente.

86-81700-00 A01

Fonctionnement

31

Evolution

F R A N A I S

3.4

Mise hors service de lUPS


Appuyez sur le bouton (10) pendant environ 2 secondes. Les dispositifs branchs lUPS ne sont plus aliments.

3.5

Commande distance de lUPS


Evolution permet deux types de commande distance.
AC OUTPUT I max 12A

RPO (mise hors tension distance) permet d'utiliser un contact distance pour couper l'alimentation de tous les dispositifs branchs l'UPS. Il faut ensuite redmarrer lUPS manuellement. ROO (Marche/Arrt distance) permet de mettre lUPS hors tension laide dune action distance du bouton (10).

2
RS232

Programmable

U.S. PAT. NO. 6,094,363


or
36Vdc, 9Ah
Pb

7
AC INPUT

1
ROO RPO

55K6 U.P.S.

Ces fonctions sont accessibles en ouvrant le contact entre les broches appropries du connecteur (7) du panneau arrire de lUPS (voir les figures ci-dessous).

Connexion et essai de commande distance


1. Assurez-vous que lUPS est hors tension et que son cordon dalimentation nest pas branch dans une prise de courant 2. Dbranchez le connecteur (7) aprs avoir retir les vis. 3. Branchez un contact normalement ferm sans tension (maximum de 60 V c.c. / 30 V c.a., maximum de 20 mA, 0,75 mm2 de section du cble) entre les deux broches du connecteur (7) (voir le diagramme).

SITE WIRING FAULT

Contact ouvert : Mise hors service de lUPS Contact ferm : Mise sous tension de lUPS (UPS branch au rseau et rseau prsent) Note : La commande Marche/Arrt locale, laide du bouton (10), supplante la fonction distance. Contact ouvert : Mise hors tension de lUPS, le voyant (14) sallume. Pour retourner en fonctionnement normal, dsactivez le contact distance (le voyant (14) steint) et appuyez sur le bouton (10) pour redmarrer lUPS. 4. 5. 6. Branchez le connecteur (7) larrire de lUPS. Branchez et mettez lUPS sous tension en suivant les procdures prcdemment dcrites. Activez le contact de mise hors tension distance pour tester la fonction.

Avertissement : Il faut brancher ce connecteur un circuit TBTS (trs basse tension de scurit).

32

Fonctionnement

86-81700-00 A01

F R A N A I S

Accs aux mesures et aux donnes de personnalisation

Insrez le CD-ROM Solution-Pac dans le lecteur. Dans le premier cran de navigation, slectionnez Solution Point point , puis suivez les instructions sur la faon dinstaller le logiciel Personal Solution-Pac. Slectionnez ensuite Configuration , Configuration avance et Configuration UPS .

Veuillez noter que les versions de Personal Solution-Pac pour Linux/Unix/MacOS noffrent pas cette option. Il est possible de modifier les rglages suivants (les dtails sur la faon de procder sont indiqus dans le logiciel Personal Solution-Pac).

Personnalisation des options de la sortie principale


Fonction
Tension de sortie sur batterie

Rglage usine 120 Volts c.a. 105%

Autres rglages possibles


100/120/127 Volts c.a.

Seuil de lalarme de surcharge

30/50/70%

Personnalisation des options du seuil de tension


Fonction Rglage lusine Autres rglages possibles 141 153 Volts c.a. 80 94 Volts c.a. 127 138 Volts c.a. 92 108 Volts c.a. Activ

Seuil suprieur de transfert la batterie 151 Volts c.a. +3% Seuil infrieur de transfert la batterie 89 Volts c.a. +3% Seuil d'activation de l'attnuateur Seuil d'activation du survolteur 132 Volts c.a. +3% 102 Volts c.a. +3%

Entre maximum - plage des tensions Dsactiv

Personnalisation des options de sensibilit de lUPS


Fonction Niveau de sensibilit de lUPS Rglage lusine Normal Autres rglages possibles
lev ou faible

86-81700-00 A01

Accs aux mesures et aux donnes de personnalisation

41

Evolution

F R A N A I S

Personnalisation des options de mise en marche/arrt de lUPS


Fonction Dmarrage automatique Dmarrage froid Mise hors service force Mode conomie d'nergie Mise en service/hors service de l'UPS par logiciel Rglage lusine Activ Activ Activ Dsactiv Activ Autres rglages possibles
Dsactiv

Dsactiv Dsactiv Activ Dsactiv 0 100%

Niveau de la batterie avant le redmarrage 0%

Personnalisation des options de la batterie


Fonction Intervalle des tests batteries Avertissement batterie faible Protection batterie contre les dcharges profondes Avertisseur sonore Rglage lusine Hebdomadaire 20% Activ Activ Autres rglages possibles
Aucun test / test quotidien / test mensuel

0 100% Dsactiv Dsactiv

42

Accs aux mesures et aux donnes de personnalisation

86-81700-00 A01

F R A N A I S

Entretien
5.1 Dpannage
Problme Lorsque vous mettez lUPS sous tension laide du bouton (10), tous les voyants sallument une fois, puis le voyant (14) demeure allum. Le bouton (10) et les voyants (13) et (14) sont allums et tous les voyants du graphique barres (8) clignotent. Le bouton (10) et le voyant (15) sont allums et tous les voyants du graphique barres (8) clignotent. Diagnostic Mesure La mise hors tension distance (RPO) Replacez le contact sa position normale, a t active pour fermer UPS et puis appuyez sur le bouton (10) pour mettre empche maintenant sa mise sous lUPS sous tension. tension.
Vrifiez la puissance de la charge des dispositifs Le pourcentage de charge est suprieur au niveau de surcharge ou branchs et dbranchez tout dispositif non prioritaire. Vrifiez le rglage de niveau de surcharge. la capacit de lUPS rgl.

Une surcharge critique est atteinte en sortie de Vrifiez la puissance de la charge des lappareil. En cas de perte du rseau dalimen- dispositifs branchs et dbranchez tout tation, les quipements ne seront pas dispositif non prioritaire. aliments en mode batterie.

Le voyant (15) est allum et tous les Une dfaillance de la batterie a t autres voyants du graphique barres dtecte durant la vrification automatique. (11) clignotent. Seul le voyant (15) est allum et l'indicateur sonore fait continuellement du bruit. Une dfaillance interne de l'UPS s'est produite et la charge n'est pas alimente.

Remplacez la batterie (voir la Section 5.2, Remplacement de la batterie).

Tlphonez au service de soutien aprs-vente.

5.2

Remplacement de la batterie dans le modle tour


Recommandations de scurit
La batterie peut causer des lectrocutions et des courants levs en court-circuit. Il faut observer les prcautions de scurit suivantes avant de faire l'entretien du compartiment de la batterie : Enlevez montre, bagues, bracelet et autres objets de mtal sur les mains et les bras, Utilisez les outils avec des poignes isoles.

Enlvement de la batterie
Tournez lUPS de la faon illustre. A. Retirez les deux vis du ct gauche.

B. Soulevez, puis tirez le panneau affichant le logo.

C. Tirez sur les deux connecteurs pour dbrancher la batterie (ne tirez pas sur les fils). D. Tirez sur la languette de plastique pour enlever la batterie.

86-81700-00 A01

Entretien

51

Evolution

F R A N A I S

Installation de la nouvelle batterie


Excutez les instructions ci-dessus dans lordre inverse. Pour assurer la scurit et un rendement optimal, utilisez seulement les batterie fournies par MGE Office Protection Systems. Durant linstallation de la nouvelle batterie, assurez-vous d'appuyer fermement l'une contre l'autre les deux parties du connecteur.

5.3

Remplacement de la batterie dans le modle rack


Recommandations de scurit
La batterie peut causer des lectrocutions et des courants levs en court-circuit. Il faut observer les prcautions de scurit suivantes avant de faire l'entretien du compartiment de la batterie : Enlevez montre, bagues, bracelet et autres objets de mtal sur les mains et les bras, Utilisez les outils avec des poignes isoles.

Enlvement de la batterie
A. Enlevez les deux vis du ct gauche du panneau avant.

B. Tirez sur les deux connecteurs pour dbrancher la batterie (ne tirez pas sur les fils).

52

Entretien

86-81700-00 A01

F R A N A I S

Manuel dinstallation et dutilisation

C. Enlevez la pice.

D. Tirez sur la languette de plastique pour enlever la batterie et remplacez-la.

Installation de la nouvelle batterie


Excutez les instructions ci-dessus dans lordre inverse. Pour assurer la scurit et un rendement optimal, utilisez seulement les batteries fournies par MGE Office Protection Systems. Durant linstallation de la nouvelle batterie, assurez-vous d'appuyer fermement l'une contre l'autre les deux parties du connecteur.

86-81700-00 A01

Entretien

53

Evolution

F R A N A I S

(Page laisse vierge volontairement)

54

Entretien

86-81700-00 A01

F R A N A I S

Annexes

6.1 Caractristiques techniques

Evolution

650 / 650 Rack

850 / 850 Rack

1150 / 1150 Rack

1550 / 1550 Rack

Puissance de sortie

650 VA / 420 W

850 VA / 600 W

1150 VA / 770 W

1550 VA / 1100 W

Puissance de sortie Tension dentre nominale Plage des tensions dentre


Place des frquences dentre de 50 Hz Place des frquences dentre de 60 Hz

120 V monophas 89 V 151 V (1) 47 Hz 70 Hz (2) 56.5 Hz 70 Hz (2)

Sortie pour lalimentation par batterie Tension Frquence Batterie (au plomb scelle, sans entretien) Modle tour Modle rack Environnement Plage de tempratures de fonctionnement Plage de tempratures d'entreposage Humidit Niveau de bruit

120 V (+6% / -10%)(3) 50/60 Hz 0.1 Hz

1 x 12 V -9 Ah 2 x 6 V -9 Ah

2 x 12 V -7.2 Ah 4 x 6 V -7.2 Ah

2 x 12 V -9 Ah 4 x 6 V -9 Ah

3 x 12 V -9 Ah 6 x 6 V -9 Ah

0 35C

0 40C

-20C 50C 20 90% (sans condensation) < 40 dbA

(1) Il est possible de rgler les seuils suprieur et infrieur laide du logiciel Personal Solution-Pac. (2) Jusqu 40 Hz en mode de frquence tendue (programmable par le logiciel Personal Solution-Pac). (3) Rglable 100 V (dclassement de 10 % de la puissance de sortie) / 120 V / 127 V. Ce produit est conu pour les systmes de distribution dalimentation des TI.

86-81700-00 A01

Annexes

A1

Evolution

F R A N A I S

6.2

Glossaire
Temps dalimentation de secours Tests de batterie Mode survolteur Le temps durant lequel la charge est alimente par la batterie de lUPS.

Test interne de lUPS pour vrifier le statut de la batterie. Mode automatique de lUPS qui augmente lalimentation c.a. si elle est trop faible un niveau suprieur au seuil configur, sans dcharger la batterie. Il est possible de dmarrer les dispositifs branchs dans lUPS mme en labsence dalimentation c.a.. LUPS fonctionne uniquement laide de la batterie. Dcharge de la batterie au-del de la limite permise, entranant des dommages irrversibles celle-ci. Mode automatique de lUPS qui diminue lalimentation c.a. si elle est trop leve un niveau infrieur au seuil configur, sans dcharger la batterie. Les dispositifs ou lquipement branch aux sorties de lUPS. Un niveau de tension de la batterie indiquant que celle-ci est faible et que lutilisateur doit prendre des mesures, car lalimentation de la charge sera bientt interrompue. La ligne de courant c.a. alimentant lUPS dans des conditions normales. Le ratio de la puissance utilise par la charge comparativement la puissance maximale de lUPS. Il est possible de personnaliser certains paramtres de l'UPS configurs en usine. Certaines fonctions de lUPS peuvent galement tre modifies laide du logiciel Personal SolutionPac pour mieux satisfaire vos besoins. Prises pouvant tre commandes pour le dlestage automatique, la mise hors tension distance et la remise sous tension (personnalises laide du logiciel Personal Solution-Pac). Systme dalimentation sans coupure. Cette fonction active ou dsactive le lancement des squences de mise en marche ou darrt de lUPS laide du logiciel de gestion de l'alimentation.

Dmarrage froid

Dcharge profonde

Mode attnuateur

Charge Avertissement de batterie faible Entre c.a. normale Pourcentage de charge

Personnalisation

Prises programmables UPS Mise en marche/arrt de lUPS command par logiciel

A2

Annexes

86-81700-00 A01

E S P A O L

Manual de instalacin y uso

Evolution
Manual de instalacin y uso

Historial de revisin
Manual de instalacin y uso, 86-81700-00 Revisin: A01 ECN#: 005225 03/2007

Copyright 2007 MGE Office Protection Systems All rights reserved. Printed in U.S.A. MGE Office Protection Systems 13 Whatney, Suite #101 Irvine, CA 92618 (949) 268-2800 For Technical Support, Customer Care Center, or Customer FAQ, please visit our website: www.mgeops.com or call (800) 279-7776

86-81700-00 A01

Evolution

E S P A O L

86-81700-00 A01

E S P A O L

Contenido

Introduccin
Proteccin del medio ambiente ..........................................................................................................1 IMPORTANTES INSTRUCCIONES DE SEGURIDAD........................................................................2 Normas de certificacin ......................................................................................................................2 Seguridad de las personas..................................................................................................................2 Seguridad del producto ......................................................................................................................2 Precauciones especiales ....................................................................................................................2 Medio ambiente ..................................................................................................................................2 Uso de smbolos..................................................................................................................................3

Presentacin
1.1 1.2 1.3 Posiciones estndar ......................................................................................................1 1 Paneles posteriores ........................................................................................................1 2 Panel de control ............................................................................................................1 2

Instalacin
2.1 2.2 2.3 2.4 2.5 2.6 Desembalaje y control del contenido ............................................................................2 Instalacin del Modelo Tower ........................................................................................2 Instalacin del Modelo Rack ..........................................................................................2 Instalacin del Modelo Rack 650 ..................................................................................2 Puertos de comunicacin ..............................................................................................2 Conexiones del equipo ..................................................................................................2 1 2 2 3 4 5

Uso
3.1 3.2 3.3 3.4 3.5 Arranque y funcionamiento normal ................................................................................3 1 Funcionamiento con alimentacin de batera ................................................................3 1 Retorno a la entrada de alimentacin de CA ................................................................3 1 Apagado de la UPS ........................................................................................................3 2 Control remoto de la UPS ..............................................................................................3 2

Acceso a Mediciones y a Personalizacin de datos


Personalizacin Personalizacin Personalizacin Personalizacin Personalizacin de la salida principal..........................................................................................4 1 del umbral de tensin........................................................................................4 1 de la sensibilidad de la UPS ............................................................................4 1 del encendido/apagado de la UPS ..................................................................4 2 de la batera ......................................................................................................4 2

Mantenimiento
5.1 5.2 5.3 5.4 Solucin de inconvenientes ..........................................................................................5 1 Sustitucin del Mdulo de la batera en el Modelo Tower..............................................5 1 Sustitucin del Mdulo de la batera en el Modelo Rack ..............................................5 2 Centro de capacitacin ..................................................................................................5 4

Apndices
6.1 6.2 Especificaciones tcnicas ..............................................................................................A 1 Glosario ..........................................................................................................................A 2

86-81700-00 A01

Contenido

ci

Evolution

E S P A O L

c ii

86-81700-00 A01

E S P A O L

Manuel dinstallation et dutilisation

Introduccin
Gracias por elegir un producto MGE Office Protection Systems para proteger su equipo elctrico. La gama Evolution ha sido diseada con el mayor cuidado. Recomendamos dedicar tiempo a leer este manual para poder aprovechar todas las caractersticas de su UPS (Fuente de alimentacin ininterrumpida, por sus siglas en ingls). Advertencia: Esta es una UPS clase A. En un ambiente domstico, este producto puede causar interferencia radial, en cuyo caso el usuario puede tener que tomar medidas adicionales. En caso que el dispositivo sea instalado en ambientes con sobretensin categora III o IV, se deber protegerlo colocando una proteccin contra sobretensin antes de la conexin a la lnea de alimentacin. Antes de instalar una Evolution, lea el folleto sobre las instrucciones de seguridad necesarias. Luego siga las indicaciones de este manual. Para descubrir toda la gama de los productos MGE Office Protection Systems y otras opciones para la gama Evolution, le invitamos a visitar nuestro sitio en internet www.mgeops.com o comunquese con su representante de MGE Office Protection Systems.

Proteccin del medio ambiente


MGE Office Protection Systems ha implementado una poltica de proteccin del medio ambiente. Los productos son desarrollados utilizando un enfoque ecolgico.

Sustancias
Este producto no contiene CFC, HCFC o asbestos.

Embalaje

El cartn que utilizamos incluye ms del 50% de cartn reciclado. Las bolsas estn hechas de polietileno. Los materiales del embalaje son reciclables y cuentan con el correspondiente smbolo de identificacin. Material Tetraftalato de polietileno Polietileno de alta densidad Cloruro de polivinilo Polietileno de baja densidad Polipropileno Poliestireno Abreviatura PET HDPE PVC LDPE PP PS Nmero del smbolo 01 02 03 04 05 06
01
PET

01
PET

Siga la reglamentacin local para la disposicin de los materiales del embalaje.

Final de la vida til


MGE Office Protection Systems procesar los productos al final de su vida til de conformidad con la reglamentacin local. MGE Office Protection Systems trabaja con compaas encargadas de recolectar y eliminar nuestros productos al final de su vida til.

Producto Este producto est hecho con materiales reciclables. El desmantelado y destruccin debe ser llevado a cabo obedeciendo todas las reglamentaciones locales sobre desechos. Al final de su vida til, este producto debe ser transportado a un centro de procesamiento de residuos elctricos y electrnicos. Batera Este producto contiene bateras de plomo/cido que deben ser procesadas conforme a la reglamentacin local sobre bateras. La batera puede ser retirada para cumplir con la reglamentacin y con el propsito de su correcta disposicin final. En nuestro sitio internet* est disponible la MSDS (Planilla de seguridad del material, por sus siglas en ingls) de las bateras. (*) Para obtener ms informacin o ponerse en contacto con nuestro gerente ambiental del Producto, use el formulario Environmental Form que aparece en el sitio: www.mgeops.com.

86-81700-00 A01

Introduccin

Evolution

E S P A O L

IMPORTANTES INSTRUCCIONES DE SEGURIDAD


GUARDE ESTAS INSTRUCCIONES. Este manual contiene instrucciones importantes
que deben ser seguidas durante la instalacin y mantenimiento de la UPS y de las bateras. Los modelos Evolution incluidos en este manual estn diseados para ser instalados en ambientes con temperaturas entre 0 y 40C, libre de contaminantes conductivos. Este equipo ha sido evaluado y se ha determinado que cumple con los lmites para un dispositivo digital Clase A, conforme a la Parte 15 de las Reglas de la FCC. Estos lmites estn diseados para brindar una proteccin razonable contra interferencia daina cuando el equipo es utilizado en un ambiente comercial. Este equipo genera, utiliza y puede irradiar energa en frecuencia radial, y en caso que no sea instalado y utilizado conforme al manual de instrucciones, puede ocasionar interferencia daina a las comunicaciones por radio. El empleo de este equipo en una zona residencial puede causar interferencia daina, en cuyo caso el usuario deber solventar los gastos para corregir la interferencia.

Normas de certificacin

Estndares IEEE 587-1980/ANSI C62.41 1980 para Capacidad para soportar saltos de tensin Reglas y normas de la FCC correspondientes a la Parte 15, Inciso B, Clase A Certificado UL con nmero 1778, Estndares para Equipo de alimentacin elctrica ininterrumpible IEC 61000-4-2 (ESD): nivel 4 IEC 61000-4-3 (Campo irradiado): nivel 3 IEC 61000-4-4 (EFT): nivel 4 IEC 61000-4-5 (Sobretensiones transitorias veloces): nivel 4 IEC 61000-4-6 (campo electromagntico) IEC 61000-4-8 (campo magntico conducido) El sistema cuenta con su propia fuente de alimentacin (la batera). Por lo tanto, las tomas de corriente pueden estar vivas inclusive si los sistemas estn desconectados de la fuente de alimentacin de CA. El sistema cuenta con un peligroso nivel de tensin. Slo lo deber abrir personal capacitado de servicio. El sistema deber contar con una buena puesta a tierra. La batera provista con el sistema contiene pequeas cantidades de materiales txicos. Para evitar accidentes, se debern seguir las siguientes directivas: -Nunca exponga una batera al fuego (riesgo de explosin). -No intente abrir la batera (el electrolito es peligroso para los ojos y la piel). -Cumpla con todas las reglamentaciones correspondientes para hacer la disposicin final de la batera. -Las bateras constituyen un peligro (choques elctricos, quemaduras). La tensin de cortocircuito puede ser muy alta. Tenga en cuenta los siguientes puntos para la manipulacin: qutese el reloj, anillos, brazaletes y cualquier otro objeto metlico, use herramientas con manijas aisladas. -No coloque herramientas ni piezas metlicas sobre las bateras. Las instrucciones para conexin y uso de la UPS descritas en este manual deben ser seguidas en el orden indicado. Se debe colocar un disyuntor de proteccin antes de la conexin a la red en un lugar de fcil acceso. El sistema puede ser desconectado de la red de alimentacin de CA abriendo este disyuntor. Controle que todas las indicaciones en la placa de datos coincidan con su sistema de alimentacin de CA y con el consumo elctrico real de todo el equipo conectado al sistema. Nunca instale el sistema cerca de lquidos o en un ambiente excesivamente hmedo. Nunca permita que ingresen elementos extraos dentro del sistema. Nunca obstruya las rejillas de ventilacin del sistema. Nunca exponga el sistema a la luz solar directa o a fuentes de calor. En caso que el sistema deba ser almacenado antes de su instalacin, hgalo en un lugar seco. El rango admisible de temperatura es de -20 C a +50 C. Todas las operaciones de manipulacin requieren de dos personas como mnimo (desembalaje, instalacin en un bastidor de sistema). Antes y despus de la instalacin, si la UPS se mantiene descargada por un largo perodo, la UPS debe ser cargada por un perodo de 24 horas al menos una vez cada 6 meses (con temperaturas normales de almacenamiento inferiores a 25 C). Esto permite cargar la batera y evitar posibles daos irreversibles. Durante el reemplazo del Mdulo de la batera, es imperativo utilizar el mismo tipo y nmero de elemento que el Mdulo de batera original provisto con la UPS para mantener el mismo nivel de rendimiento y seguridad. En caso de duda, pngase inmediatamente en contacto con su representante MGE Office Protection Systems. Este producto ha sido diseado para respetar el medio ambiente: No contiene Clorofluocarbono (CFC) o Hidroclorofluocarbono (HCFC). Reciclado de la UPS al final de su vida til: MGE Office Protection Systems se encarga de reciclar, por medio de empresas autorizadas y que cumplen con todas las reglamentaciones vigentes, todos los productos UPS recuperados al final de su vida til (pngase en contacto con una sucursal de MGE Office Protection Systems). Embalaje: Los materiales del embalaje de la UPS deben ser reciclados conforme a la reglamentacin vigente. ADVERTENCIA: Este producto contiene bateras de plomo/cido. El plomo es una sustancia peligrosa para el medio ambiente en caso que no sea reciclado correctamente por compaas especializadas.

Seguridad de las personas


Seguridad del producto


Precauciones especiales

Medio ambiente

Introduccin

86-81700-00 A01

E S P A O L

Manual de instalacin y uso

Uso de smbolos

Las instrucciones son importantes y siempre deben ser seguidas.

Informacin, consejo, ayuda.

Indicacin visual.

Accin.

Seal audible.

LED apagado.

LED encendido.

LED parpadeando.

86-81700-00 A01

Introduccin

Evolution

E S P A O L

(Esta pgina ha quedado intencionadamente en blanco)

86-81700-00 A01

E S P A O L

Presentacin

1.1

Posiciones estndar
Modelos Tower

Dimensiones (A x A x P) en pulgadas Evolution 650 Evolution 850 Evolution 1150 Evolution 1550 5,8 x 9,2 x 16,5 5,8 x 9,2 x 16,5 5,8 x 9,2 x 16,5 5,8 x 9,2 x 19,4

Pesos en libras Evolution 650 Evolution 850 Evolution 1150 Evolution 1550 18,8 24,5 27,2 36

Modelos Rack
Dimensiones (A x A x P) en pulgadas Evolution 650 Rack Evolution 850 Rack Evolution 1150 Rack Evolution 1550 Rack 17,2 x 1,7 x 14,4 17,2 x 1,7 x 20,2 17,2 x 1,7 x 20,2 17,2 x 1,7 x 21,9

Pesos en libras Evolution 650 Rack Evolution 850 Rack Evolution 1150 Rack Evolution 1550 Rack 22,7 36 37 44,3

86-81700-00 A01

Presentacin

11

Evolution

E S P A O L

1.2

Paneles posteriores
Evolution 650/850/1150/1550
(1) Ranura para tarjeta opcional de comunicaciones
AC OUTPUT I max 12A

(2) Cable de alimentacin de 6 pies con fusible 515P de 15A (3) 2 NEMA 5-15R para conexin del equipo (4) Puerto de comunicacin RS232
2

Programmable

U.S. PAT. NO. 6,094,363


or
36Vdc, 9Ah
Pb

(5) 2 salidas programables NEMA 5-15R


R

RS232

(6) Puerto de comunicacin USB


a

1
ROO RPO

55K6 U.P.S.

AC INPUT

(7) Conector para RPO/ROO remoto (Apagado remoto / Encendido-Apagado remoto) (a) LED indicador de alarma por falla de cableado del sitio con botn de reseteo

Evolution 650/850/1150/1550 Rack


Evolution 650/850/1150 Rack
Programmable 1 2
55K6 (E87247)

SITE WIRING FAULT

AC INPUT

Pb
AC OUTPUT

RS232

or

RPO ROO

Site wiring fault

Evolution 1550 Rack


36Vdc, 9Ah
Pb

AC OUTPUT I max 12A


U.S. PAT. No. 6,094,363
R

Programmable

AC INPUT

AC Input Volt 120V~1O Amps 12A MAX Hertz 50/60 Hz AC Output Volt 100/120/127V~1O Amps 12.96/12/11.34A Hertz 50/60 Hz W/VA 1100W/1440VA

RS232

or

RPO ROO

55K6 U.P.S.

SITE WIRING FAULT

1.3

Panel de control
(8) Barra grfica que indica el porcentaje de carga (9) Salida programable 1 alimentada (10) Botn ON/OFF para la UPS y las salidas (11) Barra grfica que indica el porcentaje de carga de la batera (12) Salida programable 2 alimentada (13) LED de carga protegida (14) LED de funcionamiento reducido (15) LED de carga no protegida

Barra grfica (8) y (11)

12

Presentacin

86-81700-00 A01

E S P A O L

Manual de instalacin y uso

Instalacin

2.1

Desembalaje y control del contenido

(16) Modelo Evolution UPS, torre o bastidor con cable de entrada conectado (18) Documentacin (19) CD-ROM del Solution-Pac

(20) Cable de comunicacin RS232 (21) Cable de comunicacin USB (22) Conjunto de montaje para bahas de 19 pulg (slo el modelo para bastidor)

Los materiales de embalaje deben ser desechados conforme a la reglamentacin local para residuos. Los materiales de embalaje estn identificados con smbolos de reciclaje para facilitar su separacin.

86-81700-00 A01

Instalacin

21

Evolution

E S P A O L

2.2

Instalacin del Modelo Tower

2.3

Instalacin del Modelo Rack


Siga los pasos 1 al 4 para montar el mdulo en los soportes.

Los soportes y los herrajes necesarios son provistos por MGE Office Protection Systems.

22

Instalacin

86-81700-00 A01

E S P A O L

Manual de instalacin y uso

2.4

Instalacin del Modelo Rack 650


Siga los pasos 1 al 3 para el montaje en el bastidor.

Montaje en pared

Los herrajes necesarios son provistos por MGE Office Protection Systems.

86-81700-00 A01

Instalacin

23

Evolution

E S P A O L

2.5

Puertos de comunicacin
Conexin del puerto de comunicaciones RS232 o USB (opcional)
Los puertos de comunicacin RS232 y USB no pueden ser utilizados al mismo tiempo. 1. Conecte el cable de comunicacin RS232 (20) o USB (21) al puerto serial o USB en el equipo de computacin.
U.S. PAT. NO. 6,094,363
36Vdc, 9Ah
Pb
R

AC OUTPUT I max 12A

Programmable

or

RS232

55K6 U.P.S.

AC INPUT

SITE WIRING FAULT

2. Conecte el otro extremo del cable de comunicacin (20) o (21) al puerto de comunicacin USB (6) o RS232 (4) en la UPS. Ahora la UPS puede comunicarse con el software de administracin de alimentacin del MGE Office Protection Systems.

Instalacin de tarjetas de comunicacin (opcional)


No es necesario apagar la UPS antes de instalar una tarjeta de comunicacin.
AC OUTPUT I max 12A

ROO RPO

Limited-access slot for the communication card

1. Retire la tapa de la ranura (1) que est sujeta con tornillos. 2. Introduzca la tarjeta de comunicacin en la ranura. 3. Fije la tapa de la ranura con los dos tornillos.

Programmable

RS232

U.S. PAT. NO. 6,094,363

or

36Vdc, 9Ah
Pb

55K6 U.P.S.

ROO RPO

AC INPUT

Caractersticas del puerto de comunicacin (opcional)


Clavijas 1, 2, 3, 5, 6: no utilizadas Clavija 4: comn (usuario) Clavija 7: batera baja Clavija 8: UPS ON, equipo alimentado Clavija 9: funcionamiento con alimentacin de batera

SITE WIRING FAULT

n.o.: contacto normal abierto Cuando se activa una seal, se cierra el contacto entre el contacto en comn (clavija 4) y la clavija de la seal correspondiente. Caractersticas del contacto (optoacoplador) Tensin: 48 V CC mx Corriente: 25 mA mx Potencia: 1,2 W

24

Instalacin

86-81700-00 A01

E S P A O L

Manual de instalacin y uso

2.6

Conexiones del equipo


Controle que las indicaciones en la placa de datos ubicada en la parte posterior de la UPS corresponde a la fuente de alimentacin de CA y el verdadero consumo elctrico de la carga total. 1. 2. Conecte el cable de alimentacin elctrica al tomacorriente de CA. Conecte las cargas a las salidas de la UPS de la manera que se muestra. Es preferible conectar primero las cargas prioritarias en las dos salidas marcadas como (3) y las cargas no prioritarias en las dos salidas programables marcadas como (5).

Para programar el apagado de las salidas (5) durante el uso de la alimentacin con batera y as optimizar el tiempo de respaldo disponible, se necesita del software de comunicacin MGE Office Protection Systems. Evolution 650/850/1150 Evolution 1550

AC OUTPUT I max 12A

3
3
2

5
5
Load
AC INPUT

Programmable

RS232

U.S. PAT. NO. 6,094,363

or

36Vdc, 9Ah
Pb

Load
R

55K6 U.P.S.

ROO RPO

Evolution 650/850/1150 Rack


Load
Programmable 1 2
55K6 (E87247)

AC INPUT

Pb
AC OUTPUT

RS232

or

RPO ROO

Site wiring fault

Evolution 1550 Rack

SITE WIRING FAULT

Load
36Vdc, 9Ah
Pb

AC OUTPUT I max 12A


U.S. PAT. No. 6,094,363
R

Programmable

AC Input

AC INPUT

Volt 120V~1O Amps 12A MAX Hertz 50/60 Hz

RS232

or

RPO ROO

55K6 U.P.S.

AC Output Volt 100/120/127V~1O Amps 12.96/12/11.34A Hertz 50/60 Hz W/VA 1100W/1440VA

SITE WIRING FAULT

86-81700-00 A01

Instalacin

25

Evolution

E S P A O L

(Esta pgina ha quedado intencionadamente en blanco)

26

Instalacin

86-81700-00 A01

E S P A O L

Uso
3.1 Arranque y funcionamiento normal
Oprima el botn (10) durante aproximadamente 1 segundo. El zumbador suena una vez y todos los LED se encienden simultneamente. En caso que haya alimentacin de CA, el botn (10) y el LED (13) estarn encendidos. La alimentacin es provista por la fuente de alimentacin de CA. En caso que las condiciones as lo permitan, la UPS llevar a cabo una prueba de la batera, indicada por los LED (11) y por el zumbador. En caso que no haya alimentacin de CA, el botn (10) y los LED (13) y (14) estarn encendidos. La alimentacin es provista por la UPS gracias a la batera. Los dispositivos conectados estn protegidos por la UPS. En caso que el LED (15) est encendido, se ha producido una falla (consulte la seccin "Solucin de inconvenientes").

3.2

Funcionamiento con alimentacin de batera


Transferencia a alimentacin con batera
Los dispositivos conectados siguen protegidos por la UPS cuando se pierde la alimentacin de CA. La energa necesaria es provista por la batera. El botn (10) y los LED (13) y (14) estarn encendidos. La alarma audible suena cada diez segundos.

Los dispositivos conectados son alimentados por la batera.

Advertencia de batera baja


El botn (10) y los LED (13) y (14) estarn encendidos. La alarma audible suena cada tres segundos.

La carga remanente en la batera es baja. Cierre todas las aplicaciones del equipo conectado porque es inminente el apagado automtico de la UPS.

Final del tiempo de respaldo de la batera


Todos los LED se apagan. Se detiene la alarma audible.

La UPS queda completamente apagada.

3.3

Retorno a la alimentacin con CA


Luego de un corte, la UPS se enciende automticamente cuando recupera alimentacin de CA (excepto se haya deshabilitado la funcin de reencendido por medio de la personalizacin de la UPS) y nuevamente se alimenta la carga.

86-81700-00 A01

Uso

31

Evolution

E S P A O L

3.4

Apagado de la UPS
Oprima el botn (10) durante aproximadamente 2 segundos. Los dispositivos conectados a la UPS ya no reciben alimentacin.

3.5

Control remoto de la UPS


AC OUTPUT I max 12A

Evolution ofrece la opcin de elegir entre dos funciones de control remoto. RPO (Apagado remoto, por sus siglas en ingls) permite utilizar un contacto remoto para desconectar todos los equipos conectados a la UPS. El reencendido de la UPS requiere de accionamiento manual. ROO (Encendido-Apagado remoto) permite el accionamiento remoto del botn (10) para apagar la UPS. Estas funciones se seleccionan abriendo el contacto conectado entre las correspondientes clavijas del conector (7) en el panel posterior de la UPS (vea la ilustracin que aparece a continuacin).

2
RS232

Programmable

U.S. PAT. NO. 6,094,363


or
36Vdc, 9Ah
Pb

7
AC INPUT

1
ROO RPO

55K6 U.P.S.

Conexin y prueba de la conexin remota


1. Controle que la UPS est apagada y desconectada de la fuente de alimentacin de CA. 2. Retire el conector (7) luego de destornillar los tornillos. 3. Conecte un contacto normal cerrado sin tensin (60 V CC / 30 V CA mx., 20 mA mx., cable de 0,75 mm2 de seccin) entre las dos clavijas del conector (7) (ver diagrama). Contacto abierto: Apagado de la UPS Contacto cerrado: Encendido de la UPS (UPS conectada a alimentacin de CA y CA disponible) Nota: El control local de encendido/apagado utilizando el botn (10) tiene prioridad sobre la funcin del control remoto. Contacto abierto: Apagado de UPS, el LED (14) se enciende Para volver al funcionamiento normal, desactive el contacto remoto externo (el LED (14) se apaga) y encienda nuevamente la UPS oprimiendo el botn (10)

4. 5. 6.

Conector de clavija (7) en la parte posterior de la UPS. Conecte y encienda nuevamente la UPS siguiendo los procedimientos descritos anteriormente. Active el contacto de apagado remoto externo para probar la funcin.

Advertencia: Este conector slo debe ser conectado a circuitos SELV (Circuito de seguridad para voltajes muy bajos, por sus siglas en ingls).

32

SITE WIRING FAULT

Uso

86-81700-00 A01

E S P A O L

Acceso a Mediciones y a Personalizacin de datos

Introduzca el CD-ROM del Solution-Pac en la lectora. En la primera pantalla de navegacin, seleccione "Point to Point solution" y siga las instrucciones sobre cmo instalar el software Personal Solution-Pac. Luego seleccione "Settings" (Configuracin), "Advanced settings" (Configuracin avanzada) y "UPS settings" (Configuracin de la UPS).

Tenga en cuenta que las versiones para Linux/Unix/MacOS del software Personal Solution-Pac no ofrecen esta posibilidad. Es posible modificar las configuraciones que aparecen a continuacin (en el software Personal Solution-Pac aparecen comentarios detallados).

Personalizacin de la salida principal


Funcin
Tensin de salida con alimentacin de batera

Configuracin de fbrica 120 Voltios CA 105%

Otras configuraciones disponibles


100/120/127 Voltios CA

Umbral de alarma de sobrecarga

30/50/70%

Personalizacin del umbral de tensin


Funcin Umbral alto para transferencia a batera Configuracin de fbrica 151 Voltios CA +3% Otras configuraciones disponibles 141 a 153 Voltios CA 80 a 94 Voltios CA 127 a 138 Voltios CA 92 a 108 Voltios CA Habilitado

Umbral bajo para transferencia a batera 89 Voltios CA +3% Umbral de activacin del atenuador
Umbral de activacin del elevador de tensin

132 Voltios CA +3% 102 Voltios CA +3%

Rango de mxima entrada de tensin Deshabilitado

Personalizacin de la sensibilidad de la UPS


Funcin Nivel de sensibilidad de la UPS Configuracin de fbrica Normal Otras configuraciones disponibles
Alto o bajo

86-81700-00 A01

Acceso a Mediciones y a Personalizacin de datos

41

Evolution

E S P A O L

Personalizacin del encendido/apagado de la UPS


Funcin Encendido automtico Encendido en fro Apagado forzado Modo de ahorro de energa Encendido/Apagado de la UPS controlado por software
Nivel de la batera antes del reencendido

Configuracin de fbrica Habilitado Habilitado Habilitado Deshabilitado Habilitado 0%

Otras configuraciones disponibles


Deshabilitado

Deshabilitado Deshabilitado Habilitado Deshabilitado 0 a 100%

Personalizacin de la batera
Funcin Intervalos entre pruebas de batera Advertencia de batera baja Proteccin de la batera contra descarga profunda Alarma audible Configuracin de fbrica Semanalmente 20% Habilitado Habilitado Otras configuraciones disponibles
No probar / prueba diaria / prueba mensual

0 a 100% Deshabilitado Deshabilitado

42

Acceso a Mediciones y a Personalizacin de datos

86-81700-00 A01

E S P A O L

Mantenimiento

5.1

Solucin de inconvenientes
Indicacin Diagstico Correccin

Cuando la UPS se enciende utilizando el El contacto del apagado remoto (RPO) Coloque el contacto nuevamente en su botn (10), se encienden todos los LED ha sido activado para apagar la UPS y posicin normal y oprima el botn (10) ahora impide encenderla nuevamente. para encender nuevamente. y el zumbador suena una vez, luego el LED(14) se mantiene encendido.
Verifique el consumo de los dispositivos conectados y Tanto el botn (10) como los LED (13) y El porcentaje de la carga es superior (14) estn encendidos y todos los dems que el nivel de sobrecarga programado desconecte aquellos que no sean prioritarios. Controle el nivel de la configuracin de sobrecarga. o que la capacidad de la UPS. LED y la barra grfica (8) destellan.

Se ha producido una sobrecarga crtica Tanto el botn (10) como el LED (15) en la salida de la UPS. En caso que se estn encendidos y todos los dems corte la alimentacin de CA, la carga no LED y la barra grfica (8) destellan. recibir alimentacin en modo batera. Se ha detectado una falla de batera El LED (15) est encendido y todos los LED de la barra grfica (11) estn durante la prueba automtica. destellando. Solamente el LED (15) est encendido y el zumbador suena de manera continua.

Verifique el consumo de los dispositivos conectados y desconecte aquellos que no sean prioritarios. Sustituya el mdulo de la batera (consulte la Seccin 5.2, sustitucin del mdulo de la batera).

Se ha producido una falla interna en la Llame al departamento de soporte UPS y no se ha alimentado la carga. postventa.

5.2

Sustitucin del Mdulo de la batera en el Modelo Tower


Recomendaciones de seguridad
La batera puede producir la electrocucin y alta tensin de cortocircuito. Se deben seguir las siguientes precauciones de seguridad antes de hacer servicios a los componentes de la batera: Qutese el reloj, anillos, brazaletes y cualquier otro objeto metlico de las manos y brazos. Use herramientas con las manijas aisladas.

Extraccin del mdulo de batera


Se debe girar la UPS como se muestra en la ilustracin. A. Retire los dos tornillos del lado izquierdo.

B. Levante y retire el panel con el logotipo.

86-81700-00 A01

Mantenimiento

51

Evolution

E S P A O L

C. Tire los dos conectores para desconectar la batera (nunca tire de los cables). D. Tire de la lengeta plstica para retirar la batera.

Instalacin del nuevo mdulo de batera


Realice las instrucciones antes mencionadas en el orden inverso. Para garantizar la seguridad y un alto rendimiento, use solamente bateras provistas por MGE Office Protection Systems. Asegrese de conectar firmemente las dos partes del conector durante el armado.

5.3

Sustitucin del Mdulo de la batera en el Modelo Rack


Recomendaciones de seguridad
La batera puede producir la electrocucin y alta tensin de cortocircuito. Se deben seguir las siguientes precauciones de seguridad antes de hacer servicios a los componentes de la batera: Qutese el reloj, anillos, brazaletes y cualquier otro objeto metlico de las manos y brazos. Use herramientas con las manijas aisladas.

Extraccin del mdulo de batera


A. Retire los dos tornillos en el lado izquierdo del panel delantero.

B. Desconecte el bloque de la batera separando los dos conectores (nunca tire de los cables).

52

Mantenimiento

86-81700-00 A01

E S P A O L

Manual de instalacin y uso

C. Retire la pieza.

D. Tire de la lengeta plstica para retirar la batera y sustiturla.

Instalacin del nuevo mdulo de batera


Realice las instrucciones antes mencionadas en el orden inverso. Para garantizar la seguridad y un alto rendimiento, use solamente bateras provistas por MGE Office Protection Systems. Asegrese de conectar firmemente las dos partes del conector durante el armado.

86-81700-00 A01

Mantenimiento

53

Evolution

E S P A O L

(Esta pgina ha quedado intencionadamente en blanco)

54

Mantenimiento

86-81700-00 A01

E S P A O L

Apndices

6.1

Especificaciones tcnicas

Evolution

650 / 650 Rack

850 / 850 Rack

1150 / 1150 Rack

1550 / 1550 Rack

Potencia de salida

650 VA / 420 W

850 VA / 600 W

1150 VA / 770 W

1550 VA / 1100 W

Entrada de alimentacin de CA Tensin nominal de entrada Rango de tensin de entrada Rango de frecuencia de entrada de 50 Hz Rango de frecuencia de entrada de 60 Hz Salida con alimentacin de batera Tensin Frecuencia Batera (sellada de plomo/cido, libre de mantenimiento) Modelo Tower Modelo Rack Medio ambiente Rango de temperatura operativa Rango de temperatura de almacenamiento Humedad Nivel de ruido

Monofase de 120 V 89 V a 151 V (1) 47 Hz a 70 Hz (2) 56,5 Hz a 70 Hz (2)

120 V (+6% / -10%)(3) 50/60 Hz 0,1 Hz

1 x 12 V -9 Ah 2 x 6 V -9 Ah

2 x 12 V -7.2 Ah 4 x 6 V -7.2 Ah

2 x 12 V -9 Ah 4 x 6 V -9 Ah

3 x 12 V -9 Ah 6 x 6 V -9 Ah

0 a 35C -20C a 50C 20 a 90% (sin condensacin) < 40 dbA

0 a 40C

(1) El umbral alto y el bajo pueden ser ajustados utilizando el software Personal Solution-Pac. (2) Hasta 40 Hz en modo de frecuencia extendida (programable utilizando el software Personal Solution-Pac). (3) Ajustable a 100 V (10% de disminucin de potencia de salida) / 120 V / 127 V. Este producto est diseado para sistema de distribucin de alimentacin para computadoras.

86-81700-00 A01

Apndices

A1

Evolution

E S P A O L

6.2

Glosario
Tiempo de respaldo Prueba de batera Modo elevacin de tensin Tiempo durante el cual la UPS puede alimentar una carga con su batera. Prueba interna de la UPS para controlar el estado de su batera. Modo automtico de la UPS que eleva la tensin de la CA en caso que sea demasiado baja hasta un nivel superior personalizado sin descargar la batera. Los dispositivos conectados a la UPS pueden ser encendidos incluso si no hay entrada de alimentacin de CA. La UPS funciona slo con su batera. La batera se descarga por debajo del lmite aceptable, lo que le causa daos irreparables. Modo automtico de la UPS que disminuye la tensin de la CA en caso que sea demasiado alta hasta un nivel inferior personalizado sin descargar la batera. Dispositivos o equipo conectado a la salida de la UPS. Este es un nivel de voltaje de batera que indica que la carga de la batera es baja y que el usuario debe tomar medidas en vista del inminente corte en la alimentacin de la carga. La lnea de CA que alimenta la UPS est en condiciones normales. Proporcin entre el consumo efectivamente tomado por la carga y la salida mxima de la UPS. Es posible modificar ciertos parmetros de la UPS programados en fbrica. Ciertas funciones de la UPS tambin pueden ser modificadas por medio del software Personal Solution-Pac para satisfacer mejor las necesidades del usuario. Salidas controlables para desconexin automtica de cargas, apagado remoto y reencendido secuencial Sistema de alimentacin ininterrumpida. Esta funcin habilita o deshabilita el control de las secuencias de encendido y apagado de la UPS por medio de una computadora.

Encendido en fro

Descarga excesiva Modo disminucin

Carga Advertencia de batera baja

Entrada normal de CA Porcentaje de carga

Personalizacin

Salidas programables UPS Encendido/Apagado de la UPS controlado por software

A2

Apndices

86-81700-00 A01

P O R T U G U E S E

Instalao e manual do usurio

Evolution
Instalao e manual do usurio

Histrico de reviso
Instalao e manual do usurio do Evolution, 86-81700-00 Reviso: A01 ECN#: 005225 03/2007

Copyright 2007 MGE Office Protection Systems All rights reserved. Printed in U.S.A. MGE Office Protection Systems 13 Whatney, Suite #101 Irvine, CA 92618
(949) 268-2800

For Technical Support, Customer Care Center, or Customer FAQ, please visit our website: www.mgeops.com or call (800) 279-7776

86-81700-00 A01

Evolution

P O R T U G U E S E

86-81700-00 A01

P O R T U G U E S E

ndice

Introduo
Proteo ambiental ..........................................................................................................................1 INSTRUES IMPORTANTES DE SEGURANA ............................................................................2 Padres de certificao ......................................................................................................................2 Segurana de pessoas........................................................................................................................2 Segurana do produto ........................................................................................................................2 Precaues especiais..........................................................................................................................2 Ambiente ..........................................................................................................................2 Uso de smbolos ..........................................................................................................................3

Apresentao
1.1 1.2 1.3 Posies padro ............................................................................................................1 1 Painis traseiros ............................................................................................................1 2 Painel de controle ..........................................................................................................1 2

Instalao
2.1 2.2 2.3 2.4 2.5 2.6 Como desembalar e verificao de contedo ................................................................2 1 Instalao do modelo Torre ............................................................................................2 2 Instalao do modelo Rack ............................................................................................2 2 Instalao do modelo 650 Rack ....................................................................................2 3 Portas de comunicao ..................................................................................................2 4 Conexes do equipamento ............................................................................................2 5

Operao
3.1 3.2 3.3 3.4 3.5 Inicializao e operao normal ....................................................................................3 Operao com bateria ....................................................................................................3 Retorno de energia por entrada de CA ..........................................................................3 Encerramento do no break ............................................................................................3 Controle remoto do no break..........................................................................................3 1 1 1 2 2

Acesso a medidas e a dados de personalizao


Personalizao Personalizao Personalizao Personalizao Personalizao da do da de da sada principal..................................................................................4 1 limite de tenso................................................................................4 1 sensibilidade do no break ................................................................4 1 LIGAR/DESLIGAR do no break ......................................................4 2 bateria ..............................................................................................4 2

Manuteno
5.1 5.2 5.3 5.4 Soluo de problemas ..................................................................................................5 1 Substituio do mdulo da bateria no modelo torre ......................................................5 1 Substituio do mdulo da bateria no modelo rack ......................................................5 2 Centro de treinamento....................................................................................................5 4

Apndices
6.1 6.2 Especificaes tcnicas ................................................................................................A 1 Glossrio ..................................................................................................................A 2

86-81700-00 A01

ndice

ci

Evolution

P O R T U G U E S E

c ii

86-81700-00 A01

P O R T U G U E S E

Introduo

Obrigado por selecionar um produto MGE Office Protection Systems para proteger seu equipamento eltrico. A linha Evolution foi criada com o maior cuidado. Recomendamos que voc leia este manual para aproveitar completamente os vrios recursos do seu no break. Aviso: Este um produto no break de classe A. Em um ambiente domstico, este produto pode provocar interferncia de rdio e, nesse caso, o usurio pode ter que tomar medidas adicionais. Se o dispositivo estiver instalado em ambientes de categoria III ou IV de sobrevoltagem, a proteo contra sobrevoltagem contra a corrente deve ser fornecida. Antes de instalar o Evolution, leia o folheto sobre as instrues de segurana necessrias. Em seguida, siga as indicaes neste manual. Para descobrir toda a gama de produtos MGE Office Protection Systems e as opes disponveis para a linha Evolution, o convidamos a visitar nosso site na Web em www.mgeops.com ou entre em contato com o representante da MGE Office Protection Systems.

Proteo ambiental
A MGE Office Protection Systems implementou uma poltica de proteo ambiental. Os produtos so desenvolvidos de acordo com a abordagem de projeto ecologicamente correto.

Substncias
Este produto no contm CFCs, HCFCs ou asbestos.

Embalagem
Para melhorar o tratamento de resduos e facilitar a reciclagem, separe os vrios componentes da embalagem. A caixa que usamos composta de mais de 50% de papelo. Sacos e sacolas so feitos de polietileno. 01 Os materiais da embalagem so reciclveis e contm o smbolo de indentificao adequado.
PET

Material Polietileno tereptalato Polietileno de alta densidade Cloreto de polivinil Polietileno de baixa densidade Polipropileno Poliestireno

Abreviao PET HDPE PVC LDPE PP PS

Nmero do smbolo 01 02 03 04 05 06

01
PET

Siga todas as regulamentaes locais para o descarte de materiais de embalagem.

Fim de vida
A MGE Office Protection Systems processar produtos no fim de sua vida de servio em conformidade com as regulamentaes locais. A MGE Office Protection Systems trabalha com empresas encarregadas de coletar e eliminar nossos produtos no fim de sua vida de servio.

Produto O produto feito de materiais reciclveis. A desmontagem e a destruio devem ocorrer em conformidade com todas as regulamentaes locais relacionadas aos resduos. No fim de sua vida de servio, o produto dever ser transportado para um centro de processamentos para resduos eltricos e eletrnicos. Bateria O produto contm baterias de cido-chumbo que devem ser processadas de acordo com as regulamentaes locais aplicveis relacionadas s baterias. A bateria pode ser removida para ficar em conformidade com as regulamentaes, objetivando o descarte correto. As Fichas tcnicas de segurana de material (MSDS) para as baterias esto disponveis no nosso site*. (*) Para obter mais informaes ou para entrar em contato com o gerente ambiental do produto, consulte Environmental Form no site: www.mgeops.com.

86-81700-00 A01

Introduo

Evolution

P O R T U G U E S E

INSTRUES IMPORTANTES DE SEGURANA


GUARDE ESTAS INSTRUES. Este manual contm instrues importantes que
devem ser seguidas durante a instalao e a manuteno do no break e das baterias. Os modelos do Evolution que so cobertos neste manual devem ser usados para instalao em um ambiente dentro de 0 C a 40 C, sem contaminante condutor. Este equipamento foi testado e descobriu-se que ele est de acordo com os limites de um dispositivo digital Classe A, de acordo com a Parte 15 das regras da FCC. Esses limites foram criados para fornecer proteo razovel contra interferncia danosa quando o equipamento for operado em um ambiente comercial. Este equipamento gera, usa e irradia energia de rdio-freqncia e, se nao instalado e usado em conformidade com o manual de instruo, pode causar interferncia nociva em comunicaes via rdio. provvel que a operao deste equipamento em uma rea residencial provoque interferncia danosa, caso em que o usurio precisar corrigir a interferncia s suas prprias custas.

Padres de certificao

IEEE 587-1980/ANSI C62.41 1980 Padro de capacidade de resistir a picos Regras e regulamentos da FCC, Parte 15, Sub-parte B, Classe A UL listado em 1778, Padres para equipamentos fornecimento de energia sem interrupo IEC 61000-4-2 (ESD): nvel 4 IEC 61000-4-3 (Campo irradiado): nvel 3 IEC 61000-4-4 (ESD): nvel 4 IEC 61000-4-5 (ransientes rpidos): nvel 4 IEC 61000-4-6 (campo eletromagntico) IEC 61000-4-8 (campo magntico conduzido) O sistema possui sua prpria fonte de alimentao (a bateria). Consequentemente, as tomadas de fora podem estar energizadas mesmo que o sistema esteja desconectada da tomada de AC da parede. Nveis perigosos de voltagem presentes no sistema. Para ser aberto somente por pessoal de servio qualificado. O sistema deve ser alterada de maneira apropriada. A bateria fornecida com o sistema contm pequenas quantias de materiais txicos. Para evitar acidentes, as diretirzes abaixo devem ser observadas: -Nunca queime a bateria (risco de exploso). -No tente abrir a bateria (o eletrlito perigoso para os olhos e para a pele). -Obedea a todas as regulamentaes aplicveis para o descarte da bateria. -As baterias constituem-se em perigo (choque eltrico, queimaduras). A corrente de curto-circuito pode ser muito alta. Devem ser tomadas precaues para qualquer manuseio: retire relgios, anis, braceletes quaisquer outros objetos de meta e use ferramentas com cabos isolados. -No deixe ferramentas ou peas de metal sobre baterias. As instrues de conexo e a operao da no break descrita nesta manual devem ser seguidas na ordem indicada. Deve ser instalado um disjuntor antes da entrada e o mesmo deve ser facilmente acessvel. O sistema pode ser desconectado da fonte de alimentao de AC desligando esse disjuntor. Confira se as indicaes na etiqueta de especificaes tcnicas correspondem a seu sistema de alimentao AC e ao real consumo de energia eltrica de todos os equipamentos conectados ao sistema. Nunca instale o sistema prximo de lquidos ou em um ambiente excessivamente mido. Nunca deixe que algum corpo estranho caia dentro do sistema. Nunca obstrua as grades de ventilao do sistema. Nunca exponha o sistema luz solar direta ou a uma fonte de calor. Se o sistema precisar ser armazenando antes da instalao, a armazenagem deve ser feita em local seco. A faixa admissvel de temperaturas de armazenamento de -20C a +50C. Todas as operaes de manuseio tero de ser con duas pessoas (desembalagem e instalao do semestre na prateleira). Antes e aps a instalao, se o no break permanecer sem energia por um perodo muito grande, o no break deve ser energizado durante um perodo de vinte e quatro horas, pelo menos uma vez por semestre (para uma temperatura de operao normal, inferior a 25C). Esse procedimento carrega a bateria, evitando possveis danos irreversveis. Durante a substituio do Mdulo da bateria, obrigatrio o uso do mesmo tipo e nmero de elementos que o Mdulo de bateria original fornecido com o no break, para manter um nvel idntico de desempenho e segurana. Em caso de dvida, no hesite em entrar em contato com o seu representante MGE Office Protection Systems. Este produto foi projetado para respeitar o ambiente: Ele no contm clorofluorocarboneto (CFC) nem hidroclorofluorocarboneto (HCFC). Reciclagem da no break aps seu tempo de vida til: A MGE Office Protection Systems se compromete a reciclar, por meio de empresas certificadas e em conformidade com os regulamentos aplicveis, todos os no break recolhidas ao final de sua vida til (entre em contato com um escritrio de filial da MGE Office Protection Systems). Embalagem: Os materiais da embalagem do no break devem ser reciclados em conformidade com os regulamentos aplicveis. AVISO: Este produto contm baterias de chumbo-cido. O chumbo uma substancia perigosa para o ambiente se no for reciclado de maneira apropriada por empresas especializadas.

Segurana de pessoas

Segurana do produto

Precaues especiais

Ambiente

Introduo

86-81700-00 A01

P O R T U G U E S E

Installation and User Manual

Uso de smbolos

Instrues importantes que devem ser sempre seguidas.

Informao, notcia, ajuda.

Indicao visual.

Ao.

Sinal audvel.

LED desligado.

LED ligado.

LED piscante.

86-81700-00 A01

Introduo

Evolution

P O R T U G U E S E

(Esta pgina foi deixa intencionalmente em branco)

86-81700-00 A01

P O R T U G U E S E

Instalao e manual do usurio

Apresentao

1.1

Posies padro
Modelos tipo torre
Dimenses (C x A x L) em polegadas Evolution 650 Evolution 850 Evolution 1150 Evolution 1550 5,8 x 9,2 x 16,5 5,8 x 9,2 x 16,5 5,8 x 9,2 x 16,5 5,8 x 9,2 x 19,4

Peso em lbs Evolution 650 Evolution 850 Evolution 1150 Evolution 1550 18,8 24,5 27,2 36

Modelos tipo rack


Dimenses (C x A x L) em polegadas Evolution 650 Rack Evolution 850 Rack Evolution 1150 Rack Evolution 1550 Rack 17,2 x 1,7 x 14,4 17,2 x 1,7 x 20,2 17,2 x 1,7 x 20,2 17,2 x 1,7 x 21,9

Peso em lbs Evolution 650 Rack Evolution 850 Rack Evolution 1150 Rack Evolution 1550 Rack 22,7 36 37 44,3

86-81700-00 A01

Apresentao

11

Evolution

P O R T U G U E S E

1.2

Painis traseiros
Evolution 650/850/1150/1550
(1) Encaixe para placa de comunicao opcional
AC OUTPUT I max 12A

(2) Cabo de fora de entrada de 6 ps conectado, com plugue 5-15P, de 15A (3) 2 NEMA 5-15R para conexo de equipamentos (4) Porta de comunicao RS232
2
RS232

Programmable

U.S. PAT. NO. 6,094,363


or
36Vdc, 9Ah
Pb

(5) 2 NEMA 5-15R para tomadas programveis


R

1
ROO RPO

(6) Porta de comunicao USB


a

55K6 U.P.S.

AC INPUT

(7) Conector para RPO/ROO remoto (Ligar remoto / LIGAR/DESLIGAR remoto) (a) LED de alarme indicador de falha na fiao local com boto de restaurao

Evolution 650/850/1150/1550 Rack


Evolution 650/850/1150 Rack
Programmable 1 2
55K6 (E87247)

SITE WIRING FAULT

AC INPUT

Pb
AC OUTPUT

RS232

or

RPO ROO

Site wiring fault

Evolution 1550 Rack


36Vdc, 9Ah
Pb

AC OUTPUT I max 12A


U.S. PAT. No. 6,094,363
R

Programmable

AC INPUT

AC Input Volt 120V~1O Amps 12A MAX Hertz 50/60 Hz AC Output Volt 100/120/127V~1O Amps 12.96/12/11.34A Hertz 50/60 Hz W/VA 1100W/1440VA

RS232

or

RPO ROO

55K6 U.P.S.

SITE WIRING FAULT

1.3

Painel de controle

(8) Grfico de barras indicando a porcentagem da carga (9) fornecida a tomada programvel 1 (10) Boto LIGAR/DESLIGAR para o no break e tomadas (11) Grfico de barras indicando o nvel da carga da bateria (12) fornecida a tomada programvel 2 (13) LED de carga protegida (14) LED de funcionamento reduzido (15) LED de carga no protegida

Grficos de barra (8) e (11)

12

Apresentao

86-81700-00 A01

P O R T U G U E S E

Instalao e manual do usurio

Instalao

2.1

Como desembalar e verificao de contedo

(16) Evolution UPS, modelo em torre ou rack com cabo de entrada conectrado (18) Documentao (19) CD-ROM Solution-Pac

(20) Cabo de comunicao RS232 (21) Cabo de comunicao USB (22) Kits de montagem para compartimentos de 19 polegadas (somente no modelo rack)

Os materiais da embalagem do no break devem ser reciclados em conformidade com os regulamentos aplicveis resduos. Os smbolos de reciclagem esto impressos nos materiais de embalagem, para facilitar a separao.

86-81700-00 A01

Instalao

21

Evolution

P O R T U G U E S E

2.2

Instalao do modelo torre

2.3

Instalao do modelo rack


Siga as etapas 1 a 4, para a montagem do mdulo em trilhos.

Os trilhos e o hardware necessrio so fornecidos pela MGE Office Protection Systems.

22

Instalao

86-81700-00 A01

P O R T U G U E S E

Instalao e manual do usurio

2.4

Instalao do modelo 650 rack


Siga as etapas 1 a 3 para montagem em rack.

Montagem em parede

Os trilhos e o hardware necessrio so fornecidos pela MGE Office Protection Systems.

86-81700-00 A01

Instalao

23

Evolution

P O R T U G U E S E

2.5

Portas de comunicao
Conexo da porta de comunicao RS232 ou USB (opcional)
As portas de comunicao RS232 e USB no podem funcionar simultaneamente. 1. Conecte o cabo de comunicao RS232 (20) ou USB (21) porta serial ou USB no computador.
2 U.S. PAT. NO. 6,094,363
36Vdc, 9Ah
Pb

AC OUTPUT I max 12A

55K6 U.P.S.

ROO RPO

2. Conecte a outra extremidade do cabo de comunicao (20) ou (21) porta de comunicao USB (6) ou RS232 (4) do no break. Agora o no break pode se comunicar com o software de gerenciamento de energia da MGE Office Protection Systems.

Programmable

or

RS232

AC INPUT

Instalao de placas de comunicao (opcional)


emplacement accs limit pour la carte de communication

SITE WIRING FAULT

No necessrio desligar o no break antes de instalar a placa de comunicao. 1. Retire a tampa do encaixe (1) presa por parafusos. 2. Insira a placa de comunicao no encaixe. 3. Prenda a tampa da placa com os dois parafusos.

Caractersticas da porta de comunicao de contacto (opcional)


Pinos 1, 2, 3, 5, 6: no usados Pino 4: comum (usurio) Pino 7: bateria fraca Pino 8: no break LIGADO, equipamento fornecido Pino 9: operao com bateria

n.ligado: normalmente, contacto aberto Quando um sinal ativado, o contacto fechado entre o pino de sinal comum (pino 4) e o pino para o sinal correspondente. Caractersticas de contacto (isolador ptico) Voltagem: 48 V CC mx Corrente: 25 mA mx Potncia: 1,2 W

24

Instalao

86-81700-00 A01

P O R T U G U E S E

Instalao e manual do usurio

2.6

Conexes do equipamento
Certifique-se de que todas as indicaes da plaqueta de identificao localizada na traseira do no break corresponde s especificaes da fonte de alimentao e do real consumo de eletricidade na carga total. 1. 2. Conecte o cabo de alimentao de energia tomada AC. Conecte as cargas s tomadas do no break conforme mostrado. prefervel conectar as cargas com prioridade s duas tomadas marcadas com o nmero (3) e as cargas sem prioridade tomada programvel marcada com o nmero (5).

Para programar o desligamento da tomada (5) durante o funcionamento da energia da bateria e dessa forma otimizar o tempo de reserva disponvel, necessrio o software de comunicao MGE Office Protection Systems. Evolution 650/850/1150 Evolution 1550

AC OUTPUT I max 12A

3
3
2

5
5
Load
AC INPUT

Programmable

RS232

U.S. PAT. NO. 6,094,363

or

36Vdc, 9Ah
Pb

Load
R

55K6 U.P.S.

ROO RPO

Evolution 650/850/1150 Rack


Load
Programmable 1 2
55K6 (E87247)

AC INPUT

Pb
AC OUTPUT

RS232

or

RPO ROO

Site wiring fault

Evolution 1550 Rack

SITE WIRING FAULT

Load
36Vdc, 9Ah
Pb

AC OUTPUT I max 12A


U.S. PAT. No. 6,094,363
R

Programmable

AC INPUT

AC Input Volt 120V~1O Amps 12A MAX Hertz 50/60 Hz AC Output Volt 100/120/127V~1O Amps 12.96/12/11.34A Hertz 50/60 Hz W/VA 1100W/1440VA

RS232

or

RPO ROO

55K6 U.P.S.

SITE WIRING FAULT

86-81700-00 A01

Instalao

25

Evolution

P O R T U G U E S E

(Esta pgina foi deixa intencionalmente em branco)

26

Instalao

86-81700-00 A01

P O R T U G U E S E

Operao
3.1 Inicializao e operao normal
Pressione o boto (10) por cerca de um segundo. A campainha soa uma vez e todos os LEDs se acendem simultaneamente. Se a fonte de alimentao AC estiver disponvel, o boto (10) e o LED (13) esto ativados. A energia fornecida pela fonte de alimentao AC. Se as condies permitirem, o no break executa um teste da bateria, indicado pelo led (11) e pela campainha. Se a fonte de alimentao AC no estiver disponvel, o boto (10) e os LEDs (13) e (14) esto ativados. A energia fornecida pelo no break, da bateria.

Os dispositivos conectados so protegidos pelo no break. Se o LED (15) estiver ativado, ocorreu uma falha (consulte a seo "Soluo de problemas").

3.2

Operao com bateria


Transferncia para a energia da bateria
Os dispositivos conectados continuam protegidos pelo no break se a energia da fonte de alimentao CA no estiver mais disponvel. A energia necessria fornecida pela bateria. O boto (10) e os LEDs (13) e (14) sao ligados. O alarme de udio soa a cada dez segundos.

Os dispositivos conectados recebem energia da bateria.

Aviso de bateria fraca


O boto (10) e os LEDs (13) e (14) sao ligados. O alarme de udio soa a cada trs segundos.

A carga restante da bateria est baixa. Desligue todos os aplicativos dos equipamentos conectados porque o desligamento do no break iminente.

Fim do tempo de reserva da bateria


Todos os LEDs se apagam. Os alarmes de udio param.

O no break completamente desligado.

3.3

Retorno de energia por entrada de AC


Aps uma interrupo de energia, o no break automaticamente reinicializado quando a energia de alimentao AC retorna (a menos que a funo de restaurao tenha sido desativada por meio de personalizao do no break) e a energia passar a ser fornecida novamente.

86-81700-00 A01

Operao

31

Evolution

P O R T U G U E S E

3.4

Desligamento do no break
Pressione o boto (10) por cerca de dois segundos. Os dispositivos conectados ao no break no mais recebem energia.

3.5

Controle remoto do no break


O Evolution permite a escolha entre funes de controle remoto.
AC OUTPUT I max 12A

O RPO (desligamento remoto) permite que se use um contato remoto para desconectar todos os equipamentos conectados as no break. A reinicializao do no break exige interveno manual. O LIGAMENTO/DESLIGAMENTO remoto permite o acionamento remoto do boto (10) para desligar o no break

2
RS232

U.S. PAT. NO. 6,094,363


36Vdc, 9Ah
Pb
R

Programmable

7
AC INPUT

1
ROO RPO

or

55K6 U.P.S.

Essas funes so obtidas abrindo-se o contato conectado entre os pinos apropriados do conector (7) no painel traseiro do no break (consulte as figuras abaixo).

Conexo e teste por controle remoto


1. Confirme que o no break esteja DESLIGADO (OFF) e desconectado da fonte de alimentao AC. 2. Retire o conector (7) aps soltar os parafusos. 3. Conecte um contato sem voltagem normalmente fechado (60 V DC / 30 V AC mx., 20 mA mx., seo transversal do cabo de 0,75 mm2) entre os dois pinos do conector (7) (consulte o diagrama). Contato aberto: Desligamento do no break Contato fechado: Patida do no break (no break conectada fonte de alimentao AC e a fonte de alimentao AC est disponvel). Nota: O controle local LIGAR/DESLIGAR usando o boto (10) substitui a funo de controle remoto. Contacto aberto: No break desligado, LED(14) permanece aceso. Para voltar para o modo normal de operao, desative o contato remoto externo (o LED (14) se apaga) e reinicie o no break pressionando o boto (10). 4. 5. 6. Ligue o plugue (7) na parte traseira do no break. Conecte e reinicie o no break, conforme os procedimentos descritos anteriormente. Ative o contacto externo de desligamento remoto, para testar a funo.

Aviso: Este conector somente deve ser conectado a circuitos SELV (Voltagem segura extra-baixa).

32

SITE WIRING FAULT

Operao

86-81700-00 A01

P O R T U G U E S E

Acesso a medidas e a dados de personalizao

Insira o CD-ROM Solution-Pac na unidade. Na primeira tela de navegao, escolha a opo "Soluo ponto a ponto" e siga as instrues acerca de como instalar o software Personal Solution-Pac. A seguir selecione a opo "Configuraes", "Configuraes avanadas" e "Configuraes do no break".

Observe que as verses do software Personal Solution-Pac para o Linux/Unix/MacOS no oferecem essa possibilidade. possvel modificar as configuraes listadas abaixo (comentrios detalhados esto disponveis no software Personal Solution-Pac).

Personalizao do ttulo principal


Funo Voltagem de sada na bateria Limite do alarme de sobrecarga Configurao de fbrica 120 Volts AC 105% Outras configuraes disponveis
100/120/127 Volts AC

30/50/70%

Personalizao do limite de tenso


Funo
Limite superior para transferncia para a bateria Limite inferior para transferncia para a bateria

Configurao de fbrica 151 Volts AC +3% 89 Volts AC +3% 132 Volts AC +3% 102 Volts AC +3%

Outras configuraes disponveis 141 a 153 Volts AC 80 a 94 Volts AC 127 a 138 Volts AC 92 a 108 Volts AC Ativada

Limite de ativao do esmaecedor


Limite de ativao da unidade de impulso

Faixa de tenso de entrada mxima Desativada

Personalizao da sensibilidade do no break


Funo No break-sensitivity level Configurao de fbrica Normal Outras configuraes disponveis
Alta ou baixa

86-81700-00 A01

Acesso a medidas e a dados de personalizao

41

Evolution

P O R T U G U E S E

Personalizao de LIGAR/DESLIGAR do no break


Funo Partida automtica Partida a frio Fechamento forado Modo de economia de energia NO BREAK LIGADO/DESLIGADO controlado pelo software Nvel da bateria antes de reiniciar Configurao de fbrica Ativada Ativada Ativada Desativada Ativada 0% Outras configuraes disponveis
Desativada

Desativada Desativada Ativada Desativada 0 a 100%

Personalizao da bateria
Funo Intervalos de teste da bateria Aviso de bateria fraca Proteo da bateria contra descarga profunda Alarme de udio Configurao de fbrica Semanal 20% Ativada Ativada Outras configuraes disponveis
Sem testes / teste dirio / teste mensal

0 a 100% Desativada Desativada

42

Acesso a medidas e a dados de personalizao

86-81700-00 A01

P O R T U G U E S E

Manuteno
5.1 Soluo de problemas
Indicao Quando dada partida no no break usando o boto (10), todos os LEDs se acendem e a campainha soa uma vez e ento o LED (14) permanece aceso. O boto (10) e os LEDs (13) e (14) permanecem ligados e todos os LEDs do grfico de barra (8) piscam. O boto (10) e o LED (15) est ligado e todos os LEDs do grfico de barra (8) esto piscando. O LED (15) est LIGADO e todos os LEDs do grfico de barra (11) esto piscando. Apenas o LED (15) est LIGADO e o alarme soa continuamente. Diagnstico O contacto de desligamento por controle remoto (RPO) foi ativado para desligar o no break e agora impede o reincio. A porcentagem de carga maior do que o especificado como capacidade de sobrecarga do no break. Correo Retorne o contacto de volta para sua posio normal e pressione o boto (10) para reiniciar.

Confira a carga total puxada pelos dispositivos conectados e desconecte quaisquer dispositivos no prioritrios. Confira a configurao do nvel de sobrecarga.

Ocorreu uma sobrecarga crtica na Confira a carga total puxada pelos sada o do no break. Se a entrada de dispositivos conectados e desconecte alimentao AC vier a falhar, a carga quaisquer dispositivos no prioritrios. no ser fornecida no modo de bateria. Foi detectada uma falha da bateria durante o teste automtico Substitua o mdulo da bateria (consulte a Seo 5.2, Substituio do mdulo de bateria).

4 5

Ocorreu uma falha interna do no break Chame o departamento de suporte e a carga no foi fornecida. ps-vendas.

5.2

Substituio do mdulo da bateria no modelo torre


Recomendaes de segurana
A bateria pode causar choques e correntes de curto-circuito. As seguintes precaues devem ser seguidas antes de qualquer manuteno nos componentes da bateria: Retire relgios, anis, braceletes quaisquer outros objetos de metal das mos, Use ferramentas com cabos isolados.

Retirada do mdulo da bateria


O no break deve ser virado, conforme mostrado na figura oposta. A. Retire os dois parafusos do lado esquerdo.

B. Levante e puxe o painl com o logotipo.

C. Puxe os dois conectores para desligar da bateria (nunca puxe pelos fios). D. Puxe a guia plstica para retirar a bateria.

86-81700-00 A01

Manuteno

51

Evolution

P O R T U G U E S E

Montagem do novo mdulo da bateria


Siga as instrues acima na ordem inversa. Para garantir segurana e alto desempenho, use somente baterias fornecidas pela MGE Office Protection Systems. Cuide de pressionar firmemente as duas partes do conector entre si durante a remontagem.

5.3

Substituio do mdulo da bateria no modelo rack


Recomendaes de segurana
A bateria pode causar choques e correntes de curto-circuito. As seguintes precaues devem ser seguidas antes de qualquer manuteno nos componentes da bateria: Retire relgios, anis, braceletes quaisquer outros objetos de metal das mos, Use ferramentas com cabos isolados.

Retirada do mdulo da bateria


A. Retire os dois parafusos do lado esquerdo do painl frontal

B. Desconecte o bloco da bateria, separando os dois conectores (nunca puxe pelos fios).

52

Manuteno

86-81700-00 A01

P O R T U G U E S E

Instalao e manual do usurio

C. Retire a pea.

D. Puxe a guia plstica para retirar o bloco da bateria e o substitua.

Montagem do novo mdulo da bateria


Siga as instrues acima na ordem inversa. Para garantir segurana e alto desempenho, use somente baterias fornecidas pela MGE Office Protection Systems. Cuide de pressionar firmemente as duas partes do conector entre si durante a remontagem.

86-81700-00 A01

Manuteno

53

Evolution

P O R T U G U E S E

(Esta pgina foi deixa intencionalmente em branco)

54

Manuteno

86-81700-00 A01

P O R T U G U E S E

Apndices

6.1 Especificaes tcnicas

Evolution

650 / 650 Rack

850 / 850 Rack

1150 / 1150 Rack 1550 / 1550 Rack

Energia de sada

650 VA / 420 W

850 VA / 600 W

1150 VA / 770 W

1550 VA / 1100 W

Fonte de alimentao CA Voltagem de entrada nominal Faixa de voltagem de entrada Faixa de freqncia de entrada de 50 Hz Faixa de freqncia de entrada de 60 Hz

Monofsico 120 V 89 V a 151 V (1) 47 Hz a 70 Hz (2) 56,5 Hz a 70 Hz (2)

Sada da energia da bateria Voltagem Freqncia

120 V (+6% / -10%)(3) 50/60 Hz 0,1 Hz

Bateria (selada de chumbo-cido, dispensa manuteno) Modelo torre Modelo rack Ambiente Faixa de temperatura de operao Faixa de temperatura de armazenamento Umidade Nvel de rudo

1 x 12 V -9 Ah 2 x 6 V -9 Ah

2 x 12 V -7,2 Ah 4 x 6 V -7,2 Ah

2 x 12 V -9 Ah 4 x 6 V -9 Ah

3 x 12 V -9 Ah 6 x 6 V -9 Ah

0 a 35C -20C a 50C 20 a 90% (sem condensao) < 40 dbA

0 a 40C

(1) Os limites superior e inferior podem ser ajustados usando o software Personal Solution-Pac. (2) At 40 Hz no modo de freqncia ampliada (programvel usando o software Personal Solution-Pac). (3) Ajustvel para at 100 V (10% de reduo de capacidade na energia de sada) 120 V / 127 V. Este produto foi projetado para sistemas de distribuio de energia para TI.

86-81700-00 A01

Apndices

A1

Evolution

P O R T U G U E S E

6.2

Glossrio
Tempo de reserva Teste de bateria Modo regulador de tenso (booster) Partida a frio Tempo durante o qual a energia pode ser fornecida pelo no break, operando a partir da bateria. Teste interno do no break para verificar o status da bateria. Modo automtico do no break que aumenta a voltagem AC se ela estiver muito baixa, para um nvel acima do ponto de ajuste personalizado, sem descarregar a bateria. Os dispositivos conectados ao no break podem ser iniciados mesmo se a energia da fonte de alimentao CA no estiver disponvel. o no break funciona com a energia suprida pela bateria. A descarga da bateria ultrapassou o limite permissvel, provocando ano irreversvel bateria. Modo automtico do no break que reduz a voltagem AC se ela estiver muito alta, para um nvel abaixo do ponto de ajuste personalizado, sem descarregar a bateria. Dispositivos ou equipamentos conectados sada do no break. um indicador de nvel baixo da voltagem da bateria, indicando que a carga da bateria est baixa e que o usurio deve agir rapidamente devido a risco iminente de interrupo de energia da carga da bateria. A fonte de alimentao AC que alimenta o no break sob condies normais. Proporo da energia efetivamente puxada pela carga na saida mxima do no break. possvel modificar certos parmetros do no break em fbrica. Certas funes do no break tambm podem ser modificados pelo software Personal Solution-Pac para melhor se adaptar s necessidades dos usurios. Tomadas programveis controlveis para rejeio de carga, desligamento remoto e tomadas reinicializaro seqencial (personalizveis usando o software Personal Solution-Pac). Sistema de alimentao ininterrupta. Esta funo ativa ou desativa a inicializao das seqncias de controle LIGAR/DESLIGAR do no break ON/OFF pelo computador software de gerenciamento de energia.

Descarga completa

Modo de atenuao

Carga Aviso de bateria fraca

Entrada normal CA Porcentagem da carga Personalizao

Tomadas programveis UPS LIGAR/DESLIGAR do UPS controlado pelo software

A2

Apndices

86-81700-00 A01

w w w. m g e o p s . c o m

Contact MGE Office Protection Systems


United States MGE Office Protection Systems 13 Whatney, Suite #101 Irvine, CA 92618 (949) 268-2800 www.mgeops.com

1 3 W h a t n e y, S u i t e # 1 0 1 , I r v i n e , C a l i f o r n i a 9 2 6 1 8 w w w. m g e o p s . c o m

Anda mungkin juga menyukai