Anda di halaman 1dari 3

Important Instructions

Subject Part No. M4986P3 N.G. Gas Valve Kit and M4987P3 L.P. Gas Valve Kit Use With 30, 50 and 75 Pound Tumblers with M405898 N.G. Gas Valve and M405935 L.P. Gas Valve

WARNING
This kit is to be installed in accordance with the manufacturers instructions and all codes and requirements of the authority having jurisdiction. In Canada, this conversion/installation shall be carried out in accordance with the requirements of the provincial authorities having jurisdiction and in accordance with the requirements of the CAN/CGA-B149.1 and CAN/CGAB149.2 installation code. Failure to follow instructions could result in serious injury, death or property damage. The qualified agency performing this work assumes all responsibility for this kit installation.
W013R4

To reduce the risk of electric shock, fire, explosion, serious injury or death: Disconnect electric power to the tumbler before servicing. Close gas shut-off valve to gas tumbler before servicing. Never start the dryer/tumbler with any guards/panels removed. Whenever ground wires are removed during servicing, these ground wires must be reconnected to ensure that the tumbler is properly grounded.
W016

Kit No. M4986P3 consists of: 1 1 1 1 1 1 1 2 2 2 1 M414578 M406934P M406881 M406789P M406880 M406936 21091 39397 430497 51782 7-10-142R1 Gas Valve Assembly, N.G. Spark Igniter High Voltage Lead Ignition Control Board Wiring Harness Assembly Mounting Bracket Connector Screw, #8 x 3/4 Screw, #10 x 3/8 Screw, #6 x 5/16 Kit Instructions

2 2 2 1

39397 430497 51782 7-10-142R1

Screw, #8 x 3/4 Screw, #10 x 3/8 Screw, #6 x 5/16 Kit Instructions

Special Tools required for this kit: Drill 1/8 drill bit 1/4 nut driver 5/16 nut driver Pipe wrenches

Kit No. M4987P3 consists of: 1 1 1 1 1 1 1 M414579 M406934P M406881 M406789P M406880 M406936 21091 Gas Valve Assembly, L.P. Spark Igniter High Voltage Lead Ignition Control Board Wiring Harness Assembly Mounting Bracket Connector
Form No. 7-10-142R1 September 2010

Page 1 of 3

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT

1. Turn off power and gas supply to machine. NOTE: The building gas supply may need to be disconnected if a shut-off valve does not exist beyond the rear entrance pipe nipple within the building.

2. Disconnect wiring to diode logic board, glow bar igniter and gas valve. Refer to Figure 1.

Glow Bar Igniter Attaching Screw Diode Logic Board Frame

Phillips Head Screw

Gas Valve Manual Gas Supply Valve (Shown in the ON position)

Molex Plug

Burner Tube

Spud Holder

Manifold

Pipe Unions

Plug

Figure 1

3. Remove diode logic board, glow bar igniter and gas valve. 4. Install M414578 or M414579 Gas Valve Assembly provided in kit. NOTE: A separate shut-off valve is no longer necessary because the new gas valve has its own shut-off. Replace or discard shut-off valve after new gas valve is installed. 5. Install M406936 Mounting Bracket using two 430497 screws. Refer to Figure 2. 6. Mount igniter using two 51782 screws. Refer to Figure 2. 7. Drill two 1/8 inch holes for mounting ignition control to the upper right of the stove assembly. Refer to Figure 2. 8. Mount M406789P Ignition Control Board using two 39397 screws. Refer to Figure 2. 9. Connect M406880 Wiring Harness Assembly to ignition control board. Refer to Figure 2.

10. Connect MV black wire to gas valve terminal 2. Refer to label on ignition control board for location of wire. This wire, V2 wire in step 10 and high voltage lead in step 14 will have to be fed through the hole in the partition between the stove assembly and where the ignition control is mounted. Refer to Figure 2. 11. Connect V2 white wire to gas valve terminal 1. 12. Connect L2 white wire to transformer secondary white wire, if present, or to the L2 wire from the diode logic board. May need to use 21091 Connector. Refer to Figure 3. 13. Connect L1 blue wire to adjustable thermostat. Refer to Figure 3. 14. Connect B/G green wire to ground. 15. Connect M406881 High Voltage Lead from igniter to ignition control board. 16. Turn on gas to machine. Check for gas leaks. 17. Turn on power and check gas valve and igniter operation and inspect burner flame.

Page 2 of 3 (7-10-142R1)

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT

Igniter and Bracket

High Voltage Lead

Wiring Harness Assembly

Screws

Ignition Control

TU050-IN

Figure 2

If present

Figure 3

Page 3 of 3 (7-10-142R1)

Copyright, Alliance Laundry Systems LLC DO NOT COPY or TRANSMIT

Anda mungkin juga menyukai