Bathroom Exhaust Range Hood Exhaust Clothes Dryer Boosting Garage Ventilation Indoor Air Quality (IAQ)
SOLVED!
S&P, the worlds leading producer of air movement products, offers a full selection of fan solutions for all of your residential ventilation requirements. Inline remote fans are the most effective way to vent todays homes and do so with less noise, better air flow and are both affordable and aesthetically appealing (the fan is hidden). In addition, S&P offers more solutions with multiple fan choices to meet all your requirements. Whatever your requirements... S&P has a solution.
Garage Ventilation...pg 41
IAQ...pg 36-39
Look for our Fans for Life symbol We certify the fans that bear this symbol offer the lowest possible energy use and running costs, while still providing the highest possible performance.
ENERGY STAR
Mixed Flow
Centrifugal
Inline/Duct
Model TD-MIXVENT
Sidewall
Ceiling
HVI
UL
x
TD-SILENT
x x x
Economical Concerns 91-1050 and Most Applications Extreme Noise Concerns Extreme High Static Pressure Concerns
Bathroom Range Hood Garage Bathroom Range Hood Garage Bathroom Range Hood Clothes Dryer Garage Bathroom Clothes Dryer Garage
x
PV-POWERVENT
x x x
108-530
x
SWF-SIDEWALL
x x x x
108-942
x
V-SERIES
x x
108-491
x
TR-SERIES
x x x x
31-150
Bathroom
x x x x
46-310
IAQ Concerns
Bathroom* IAQ
*See IAQ Applications (page 40) for information on using the TR-Series for Bathroom Exhaust
Applications
PV-POWERVENT SERIES
Technical Specifications
Warranty Five (5) year limited warranty. Range All twelve (12) PV model sizes (PV 100, 100x, 125, 125x, 150, 150x, 200, 200x, 250, 250x, 315 and 315x) include the following specifications: Casing Manufactured from high grade pressed galvanized steel, with black baked enamel coating. Extra long inlet and discharge collars make installation quick and trouble free. Supplied with a strong galvanized steel mounting bracket. Supplied with a prewired junction box. Wheel / Impeller Backward curved centrifugal type constructed of metal. Factory matched to an external rotor motor and dynamically balanced to eliminate vibration. Accessories A wide range of accessories is available to complete the most demanding installation. Motor Totally enclosed permanent split capacitor start and run external rotor motors. 115V 60Hz (single phase) electrical connection. Permanently sealed, self lubricating precision ball bearings. Safety Thermal Overload Protection Cut-Out (Automatic Reset Type). All Models are suitable for working airstreams up to 140 F Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed. Independently safety tested by Intertek Laboratories, and are ETL Listed. Independently tested for Airflow Performance. The PV range is licensed to bear the AMCA seal for Air Performance. The PV product range is certified by the Home Ventilating Institute (HVI) for Air Performance. PV-150x and larger are ENERGY STAR qualified. All models are NAHB - National Green Building Green Approved.
PV-POWERVENT SERIES
Dimensional Data
A
Dimensions (inches/mm)
Weight lbs(kgs)
313/16 313/16 43/4 711/16 71/2 43/4 99/16 7 97.5 97.5 120 196 190 120 243 313/16 313/16 43/4 711/16 71/2 43/4 99/16 7 97.5 97.5 120 196 190 120 243 413/16 413/16 43/4 713/16 71/2 43/4 99/16 7 122.5 122.5 120 198 190 120 243 413/16 413/16 43/4 713/16 71/2 43/4 99/16 7 122.5 122.5 120 198 190 120 243 513/16 147 513/16 147 713/16 198 713/16 198 93/4 248 93/4 248 93/4 248 93/4 248 43/4 120 713/16 198 43/4 120 713/16 198 43/4 120 513/16 147 43/4 120 83/4 223 513/16 147 43/4 120 43/4
87/16 95/16 43/4 131/8 11 120 214 236 120 334 5.0 87/16 95/16 43/4 131/8 11 214 236 120 334 5.0 83/4 223 95/16 43/4 131/8 11 236 120 334 5.0 95/16 43/4 131/8 11 236 120 334 5.0
B E
PV-250 PV-250x
81/16 95/16 43/4 131/8 13 205 236 120 334 6.0 81/16 95/16 43/4 131/8 13 205 236 120 334 6.0
PV-315 PV-315x
125/16 43/4 93/16 109/16 43/4 1513/16 21 125/16 312 312 120 233 269 120 401 10.0 125/16 125/16 43/4 93/16 109/16 43/4 1513/16 21 312 312 120 233 269 120 401 10.0
Technical Data
Air Performance
Trade Name Model No. Nom. RPM Volts Max. Watts CFM v Static Pressure (SP) Ins. WG 0 0.125 0.25 0.375 0.5 0.75 1.0 1.25 1.5 Max. SP Duct Dia. Ins.
Power Vent-100 Power Vent-125 Power Vent-150 Power Vent-200 Power Vent-250 Power Vent-315
1400 2880 2350 2745 2750 2700 3100 2930 3000 3045 2600 2650
115 115 115 115 115 115 115 115 115 115 115 115
108 153 128 206 245 390 402 544 587 618 654 942
100 142 104 190 205 367 375 515 555 595 605 905
92 130 85 170 177 340 350 485 525 570 570 859
85 120 74 153 157 312 327 446 495 540 525 811
78 111 63 135 129 285 296 415 472 510 487 762
1.7 1.85 1.43 1.77 1.2 2.05 1.94 2.64 2.61 2.8 2.21 3.9
4 4 5 5 6 6 8 8 10 10 12.4 12.4
Power Vent-100x PV-100x Power Vent-125x PV-125x Power Vent-150x PV-150x Power Vent-200x PV-200x Power Vent-250x PV-250x Power Vent-315x PV-315x
Performance certified is for installation type D-Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM or RPS) shown is nominal. Performance is based on actual speed of test.
Soler & Palau USA certifies that the PV range shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The PV-POWERVENT Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.
Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.
5
SWF-SIDEWALL SERIES
Technical Specifications
Warranty Five (5) year limited warranty. Range All five SWF models sizes (SWF 100, 100x, 150, 150x & 200) include the following specifications: Casing Manufactured from high grade pressed galvanized steel, with baked enamel coating. Removable top for easy access to motor for cleaning or inspection. Large grille opening for easy passing of lint and other potentially clogging materials. Includes prewired terminal box. Wheel/Impeller Backward curved centrifugal type. Factory matched to an external rotor motor and dynamically balanced to eliminate vibration. Accessories A wide range of accessories is available to complete the most demanding installation. Motors Totally enclosed permanent split capacity start and run external rotor motors. 115V 60Hz (single phase) electrical connection. Permanently sealed, self lubricating precision ball bearings. Safety Thermal Overload Protection Cut-Out (Automatic Reset Type). All models are suitable for working airstreams up to 140F. Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL listed. The SWF product range is certified by the Home Ventilating Institute (HVI) for Air Performance. All models are NAHB - National Green Building Green Approved.
SWF-SIDEWALL SERIES
Dimensional Data
A
Dimensions (inches/mm)
D
A
1/4
B
13
1/4
C
9 228 9 228 10 10 254 11
7/16 3/16
C1
3 76 3 76 3 76 3 3/16 81 3
3/8
C2
2
7/16
D
4 100 4 100 6 150 6 150 8 200
62 2 7/16 62 2
7/16
B C1 C2
SWF-150
C
256
62 2 7/16 62 2
7/16
SWF-150x SWF-200
394
408
290
87
62
Technical Data
Air Performance
Model SWF-100 SWF-100X SWF-150 SWF-150X SWF-200 CFM v Static Pressure (SP) Ins. WG 0 108 153 250 369 491 0.125 92 135 215 247 445 0.25 79 127 185 315 417 0.375 64 117 157 293 383 0.5 50 104 133 258 346 0.75 27 80 93 205 282 1.0 11 55 55 157 220 1.25 25 24 109 160 1.5 62 105
The SWF-SIDEWALL Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.
Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.
Construction characteristics
Polypropylene housing Steel housing with epoxy coating ABS fan blades Aluminum fan blades Thermal link via fuse Thermal link with automatic reset Permanently lubricated ball bearings Speed controllable 2-speed motor 100 100x 125 150 200 250 315
The extensive range of the TD-MIXVENT series makes it an effective solution for a wide range of residential and light commercial ventilation installations.
The low profile of the fans in the TD-MIXVENT range makes them the ideal product for installations with low height limits, such as the case of suspended ceilings.
Easy to Install
Flexibility in Location
Option 2
Easy Maintenance
Option 1
Removable body, for repair or cleaning, without the need to touch the ducts.
The fans can be connected at any point along the ventilation duct: along the duct or at the end. 9
TD-MIXVENT SERIES
Technical Specifications
Warranty Five (5) year limited warranty.
Range The TD-MIXVENT series consists of seven (7) nominal sized in-line fans. All models are specifically designed for direct connection in-line with industry standard diameter round ducting. Construction The TD-MIXVENT models 100, 100x, 125,150, and 200 are manufactured in tough reinforced plastic, models 250 and 315 have a metal casing and are finished in a tough epoxy-polyester paint coating. The TD fan duct connection flanges are manufactured from reinforced plastic, except for models 200, 250 and 315 which are constructed from epoxy-polyester coated metal. Impellers The impeller blades for models 100, 100x, 125, 150 and 200 are molded in tough ABS plastic. Models 250 and 315 are metal. Motors Models 100, 100x and 125 : Single-phase, 120V 60Hz, shaded pole induction asynchronous motor in die cast aluminum. All motors include direct two speed connection and are also suitable for voltage speed control. Class ll electrical insulation (model 100) & Class l (models 100x and 125) IP 44 Protection Class B Motor Insulation Safety auto reset Thermal Overload Protection (fuse type) Self-lubricating sleeve bearings. Suitable for working airstreams up to 104 F (40C). Models 150, 200, 250 and 315: Single-phase induction asynchronous motor, with permanent capacitor and external rotor constructed of die cast aluminum. Models 150, 200 and 315 include direct two speed connection and are also suitable for voltage speed control. Class I electrical insulation IP 44 Protection Thermal Overload Protection Class B Motor Insulation Sealed For Life, ball bearings Suitable for working airstreams up to 140 F (60C). Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed. Independently tested for Airflow Performance. The PV range is licensed to bear the AMCA seal for Air Performance. The TD product range is certified by the Home Ventilating Institute (HVI) for Air Performance. All models are ENERGY STAR qualified. All models are NAHB - National Green Building Green Approved.
10
TD-MIXVENT SERIES
Dimensional Data
Dimensions (inches/mm)
Model TD-100 TD-100x TD-125 TD-150 TD-200 TD-250 TD-315
5 7 7 8
X
15/16
A
9
1/8
B
5
7/16
C
3 4 4 5 127 5 9/16 141 7 9/16 192 8 13/16 224
3/4
D
3
7/8
E
3
1/4
F
3
3/4
G
1
7/8
H
2 2 2 2
1/16
151
3/8
232 11 15/16 303 10 3/16 258 5/8 11 295 11 7/8 302 15 3/16 386 17 11/16 450 6
138
15/16 1/2
96 3 115
1/2
98
13/16
82 3
15/16
95 3
9/16
48 3 3 3
1/8
52
3/8
188
3/8
176 6 15/16 176 7/8 7 200 8 9/16 217 10 11/16 272 13 1/4 336
97 4 13/16 123 13/16 5 147 7 13/16 198 9 3/4 248 12 5/16 312
100 3 15/16 100 7/16 4 112 4 7/8 124 6 1/8 155 7 3/8 188
80
1/8
60
3/8
188
3/8
115
80
1/8
60
3/8
60 3 15/16 3 11/16 100 94 5 11/16 5 1/2 145 140 7 3/16 7 182 178
80
Technical Data
Air Performance
Model Nom. RPM 2431 2516 1556 2096 1633 2146 1709 2289 2322 2781 2400 3200 2000 2500 Volts 120 120 120 120 120 120 120 120 120 120 115 115 115 115 Max. Watts 23 26 20 33 24 38 54 65 139 184 162 241 208 335 Speed LS HS LS HS LS HS LS HS LS HS LS HS LS HS CFM v Static Pressure (SP) Ins. WG 0 97 101 100 135 149 197 218 293 476 538 541 754 751 1050 0.125 81 85 77 113 110 168 193 273 422 495 475 715 670 990 0.25 51 57 48 90 73 133 163 250 373 458 418 680 545 932 0.375 53 86 128 227 317 418 355 640 420 850 0.5 22 105 206 260 367 295 606 285 770 0.75 24 131 40 190 218 520 190 600 1.0 35 10 170 405 130 420 Max. SP .4 .4 .375 .55 .35 .55 .8 1.15 1.38 1.625 2.03 2.53 1.62 2.95 Duct Dia. Ins. 4 4 4 4 5 5 6 6 8 8 10 10 12.4 12.4
TD 100
TD 100x
TD 125
TD 150
TD 200
TD 250
TD 315
Performance certified is for installation type D-Ducted inlet, Ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). Speed (RPM or RPS) shown is nominal. Performance is based on actual speed of test.
Soler & Palau USA certifies that the TD range shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and comply with the requirements of the AMCA Certified Ratings Program.
The TD-MIXVENT Series fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.
Sound Fan sound levels are measured in sones. At this time there are no sone level test standards available through HVI due to the fact that remote mounted fan noise levels are in proportion to the following: type of duct, length of duct, fan distance from the intake source and other miscellaneous factors. However, it is generally accepted that remote mounted venting is usually quieter than standard (in room) venting.
11
Rubber Gasket
Support Brackets
The low profile of the fans in the TDSILENT range makes them the ideal product for installations with low height limits, such as the case of suspended ceilings.
Sound waves produced inside the TD, are directed through the perforated inner skin and absorbed by the layer of soundabsorbent material.
Easy Maintenance
Bi-material support brackets, which in addition to simplifying installation, serve as joint seals.
Connection box can be rotated 360, to facilitate easy connection of the power cable.
Duct Air-Seals
Bi-material inlet and outlet incorporating a flexible washer to facilitate installation, absorb vibrations and provide a virtually air-tight seal.
Mounting bracket for installing on a wall or ceiling, incorporating twin-material support brackets for the motor section that absorbs vibration.
13
14
TD-SILENT SERIES
Technical Specifications
Warranty Five (5) year limited warranty.
Range The TD-SILENT consists of four (4) nominal sized in-line fans. All models are specifically designed for direct connection in-line with industry standard diameter round ducting. Construction The TD-SILENT models 100XS (4 or 5), 150S and 200S are manufactured in tough reinforced plastic. Sound waves are directed through the perforated inner skin and absorbed by a layer of sound-absorbent insulation. Plus the TD-SILENT is fitted with rubber gaskets on the inlet and outlet to absorb vibrations. Impellers The impeller blades are molded in tough ABS plastic. Motors Models 100XS: Single-phase, 120V 60Hz, shaded pole induction asynchronous motor in die cast aluminum. All motors include direct two speed connection and are also suitable for voltage speed control. Class l electrical insulation IP 44 Protection Class B Motor Insulation Safety auto reset Thermal Overload Protection (fuse type) Self-lubricating sleeve bearings. Suitable for working airstreams up to 104 F (40C). Models 150S and 200S: Single-phase induction asynchronous motor, with permanent capacitor and external rotor in die cast aluminum. All models include direct two speed connection and are also suitable for voltage speed control. Suitable for working airstreams up to 140 F (60C). Class I electrical insulation IP 44 Protection Thermal Overload Protection Class B Motor Insulation Sealed For Life, ball bearings Code Approval All models have been independently safety tested by Underwriters Laboratories, Inc. and are UL and cUL Listed. Independently tested for Airflow Performance. The TD product range is certified by the Home Ventilating Institute (HVI) for Air Performance. All models are ENERGY STAR qualified. All models are NAHB - National Green Building Green Approved.
15
TD-SILENT SERIES
Air Performance
All models include a direct two speed motor connection.
Model Duct Dia. Ins. Nom. RPM Volts Max. Watts Speed CFM v Static Pressure (SP) Ins. WG 0 0.125 0.25 0.375 0.5 0.75 1.0 Max. SP Max operating temp. (F) Wgt. (lbs)
21 35 21 36 55 65 115 122
LS HS LS HS LS HS LS HS
77 46 204
104 104 104 104 140 140 140 140 13.2 19.2 11.9
The TD-SILENT Models 100XS and 150S are California Title 24 compliant and meet ASHRAE 62.2 when installed with a CVC and other TD models are compliant when installed with a 3 way switch and remotely mounted speed control.
Dimensions (inches)
16
Performance Model V50 V80 V110 V150 CFM 50/31 80/60 110/93 150/110 Static Pressure (in W.G.) 0.1/0.25 0.1/0.25 0.1/0.25 0.1/0.25 Energy Efficiency Watts (CFM/Watts)* 4.5 12.9 5.1 16.1 4.6 24.2 4.5 32.7 Power (V/Hz) 120/60 120/60 120/60 120/60 Sones <0.3 <0.3 0.8 <0.3 Amps 0.12 0.15 0.21 0.29
* Energy Star qualified data based on tested air flow and power consumption.
Dimensions Duct Model Dia. V50 V80 V110 V150 4 4 4 6 Grille Size (Sq.) Cabinet Size W H D 8-1/16 8-1/16 8-1/16 9-9/16 Unit Wgt./ Ship Wgt. (lbs) 7.7/10.4 7.7/10.4 7.7/10.4 12.3/16.2
13 x 13 9-7/8 9-7/8 13 x 13 9-7/8 9-7/8 13 x 13 9-7/8 9-7/8 13-5/8 x 13-5/8 12-1/16 12-1/16
17
Standard Features MERV-8 filters Less than 1 watt stand-by power consumption Transformer/relay package allowing simple on/off control Plastic double collars for 6 or 8 direct duct connection (TR300 is 8 only) 3 power cord Integral mounting flange and hanging bracket system Fully insulated case Large cores for high efficiency No condensate pan or drain required 10-year industry best core warranty 2-year warranty on balance of unit
LISTED
Models compatible to any HVAC equipment Simple installation Mount in any orientation May be installed in unconditioned locations like attics and garages Easy-to-access field support Elimination of callbacks Green Building compliant
Specifications
Electrical: 120 V, 60 Hz, Single Phase, 1.0 FLA, contains one 0.1 hp motor Dimensions: unit case=25-1/8W x 20-1/8H x 10-1/8D carton=21W x 29-1/2L x 15H Weight: unit=44 lbs, in carton=52 lbs Electrical: 120 V, 60 Hz, Single Phase, 1.3 FLA, contains one 0.1 hp motor Dimensions: unit case=28-3/4W x 20-1/8H x 13D, carton=21W x 32L x 17-1/2H Weight: unit=58 lbs, in carton=65 lbs Electrical: 120 V, 60 Hz, Single Phase, 1.5 FLA, contains one 0.1 hp motor Dimensions: unit case=28-3/4W x 20-1/8H x 23-7/8D carton=21-1/2W x 32L x 29H Weight: unit=80 lbs, in carton=88 lbs Electrical: 120 V, 60 Hz, Single Phase, 3.3 FLA, contains one 0.2 hp motor Dimensions: unit case=28-3/4W x 20-1/8H x 23-7/8D carton=21-1/2W x 32L x 29H Weight: unit=72 lbs, in carton=85 lbs
Watts Temp Eff % Total Winter % Total Summary % Airflow (CFM) Watts Temp Eff % Total Winter % Total Summary % Airflow (CFM) Watts Temp Eff % Total Winter % Total Summary % Airflow (CFM) Watts Temp Eff % Total Winter % Total Summary %
We spend hours upon hours in our bathrooms; why not make them as comfortable as possible? No more loud noisy fans that instantly alert you the moment you hit the switch. If the strongest, quietest, bathroom exhaust system is what you seek, look no further. S&P offers a range of inline fans or ceiling mounted fans that offer several advantages over traditional bathroom fans to fit exactly what you need. Our TDMIXVENT and PV-POWERVENT lines of fans are available in convenient, all inclusive kits to provide the ultimate bathroom ventilation system. Whether you choose from the popular, and exclusive, TD series bathroom exhaust kits (for single or dual venting points), or the ultra powerful PV series kits (also, in single or dual vents) for long or complicated duct runs, all S&P bath kits feature a powerful fan mounted in the attic (away from the living space). The result is a Turbo powered fan (much stronger than generally associated with bathroom exhaust) and yet a peacefully quiet operation. If your concern is noise, the TDSILENT is the fan for you, with a built in sound attenuator and remote mounting the TD-SILENT is the fan you will never hear. You also have the choice of the SWF sidewall series fan, featuring the powerful PV motor, when attic space or easy indoor access is difficult or not suitable for traditional in-line mounting. Finally, if a ceiling mounted fan is what you need, our V-Series bathroom fans, are the most energy efficient line of ceiling mounted ventilation fans available in North America. Our remote mounted fans are powerful enough to vent multiple areas with one unit (dual vent - dv kits) for todays larger bathrooms; venting multiple bathrooms with one unit is also possible. The remote mounting feature allows peace and quiet in the living space, thus reducing the sound level of a generally noisy fan. S&P remote fans also offer extended duty times, are low maintenance and help reduce moisture, which decreases the likelihood of mold or mildew. Plus, they do not detract from the homes aesthetics unlike some unsightly roof mounted units. S&P remote fans are the clear choice for the strongest, quietest installation. In addition to our fans and kits, S&P offers a complete line of grilles and switches. When used in combination S&P offers the perfect solution with the most options!
TD-MIXVENT SERIES
TD-SILENT SERIES
TR-SERIES
19
Bathroom
SOLVED!
Bathroom
20
For the most effective bathroom ventilation, HVI recommends eight air changes per hour. Fans should be installed as close to the shower as possible and, if marked as suitable for this location, directly over it to capture the moisture as directly as possible. Your fan should have a control that will allow the fan to run at least 20 to 30 minutes after each shower. An enclosed toilet should have its own exhaust fan. Fans should be located over the shower or tub. Bathroom doors need to have at least 3/4 clearance to the finished floor to allow entry of makeup air. The Perfect Addition Using a timer or other control ensures that ventilation Need to meet ASHRAE 62.2 or continues for a minimum of 20 minutes after use of looking to continuously ventilate the bathroom. For steam showers, we recommend your bathroom? You can use a separate fan in the steam room that you can turn our CVC - Continuous Ventilation on after use. Bathroom (continuous ventilation) should be available on a continuous basis at a Control with any switch you choose! minimum of 20 CFM in lieu of an intermittent 50 (only available for use with TD fans) CFM fan.
Innovative Features
Low Noise Levels Duct Air-Seals
Sound waves produced inside the TD, are directed through the perforated inner skin and absorbed by the layer of soundabsorbent material.
Bi-material inlet and outlet incorporating a flexible washer to facilitate installation, absorb vibrations and provide a virtually air-tight seal.
When you use our TD-SILENT series with our VL-Vent Light you get ventilation that is Out-of-Sight and Out-of-Mind! The Vent Lights appear to be a regular can light, and when combined with a remotely mounted TD fan, the noise and unsightly look of the traditional bathroom fan are gone! The Vent Lights are aesthetically pleasing grilles with lights that will match any bathroom decor.
Features
Reduces remodeling costs, helps meet ASHRAE 62.2 requirements Perfect for homes, apartments, dorms, hotels and elderly housing Economical and easy to install in your existing wall box Works with most fan controls, i.e. motion sensors, timers, speed controllers. Dimensions in Inches (mm) Improves the indoor air quality in your home Undetectable, efficient and effective Operates with any standard switch No programming required 120V, 60 Hz, 3A Maximum
Easy Installation. . .
1
Attaches to any standard wall switch.
2
Simple 2 wire connection across the wall switch and fits into most standard wall/ junction boxes.
3
Completely installed in minutes!
S&P PV-POWERVENT Series fans are also available as easy-to-install kits. This ultra powerful bathroom fan offers a choice of single or dual vent exhaust. These kit are used for installations that require long or complicated duct runs. All PV kits have a standard 8-year warranty.
KIT-PV100 1 PV100 exhaust fan 1 plastic round grille (PG-100) Mounting bracket KIT-PV100x 1 PV100x exhaust fan 1 plastic round grille (PG-100) Mounting bracket KIT-PV150 1 PV150 exhaust fan 1 plastic round grille (PG-150) Mounting Bracket
KIT-PV100x-DV 1 PV100x exhaust fan 2 plastic round grilles (PG-100) 1 Y-fitting (SY-4) Mounting Bracket KIT-PV150-DV 1 PV150 exhaust fan 2 plastic round grilles (PG-150) 1 Y-fitting (SY-6) Mounting Bracket KIT-PV200-DV 1 PV200 exhaust fan 2 plastic round grilles (BOR-200) 1 Y-fitting (SY-8) Mounting Bracket
S&P Bathroom CFM @ 0 Single or Kit Model SP Dual Venting Standard Exhaust Kits KIT-TD100 Low: 97 High: 101 KIT-TD100x Low: 100 High: 135 Low: 218 High: 293
Light
ENERGYSTAR Qualified
Warranty in Years
Single
Yes
Single
Yes
KIT-TD150
Single
Yes
KIT-PV100 108 KIT-PV100x 153 KIT-PV150 245 Single Yes 8 Single 8 Single 8
Standard Lighted Exhaust Kits KIT-TD100XL Low: 100 Single High: 135 KIT-TD100XH Low: 100 High: 135 Low: 100 High: 135
LED
Yes
7*
Single
Halogen
Yes
7*
KIT-TD00XF
Single
Fluorescent
Yes
7*
Deluxe Exhaust Kits KIT-TD150DV Low: 218 High: 293 KIT-PV100x-DV 153 KIT-PV150-DV 245 KIT-PV200-DV 402 Deluxe Lighted Exhaust Kits KIT-TD150L Low: 218 High: 293 KIT-TD150H Low: 218 High: 293 KIT-TD150F Low: 218 High: 293
Dual
Yes
Dual
Dual
Yes
Dual
Yes
Dual
LED
Yes
7*
Dual
Halogen
Yes
7*
Dual
Fluorescent
Yes
7*
S&Ps Grille Options give you the choice of seven (7) aesthetically pleasing grilles designed to match any bathroom decor. You can choose from our Vent Lights, Premium Grilles or Adjustable Grilles to fit your needs. These grilles are designed to be used exclusively with one of S&Ps remotely mounted inline fans (TD, PV, SWF) for virtually silent bathroom ventilation. Inline fans give you the option to mount your grille over the shower, toilet, tub, or in multiple locations (dual vent). With S&Ps Grille Options the choice is yours!
Vent Lights
Dimensions (inches)
7 sq.
5 2.2
5.25
13
-2
Features: Longer duct collar for 4 duct Extendable hanger bars up to 24 7.5 grille Built-in backdraft damper 3 bulb options
9
Premium Grilles
PG Bathroom
32
PGD S&Ps premium grilles come standard with steel collars for easy mounting and installation. They are available with (PGD) and without (PG) backdraft dampers.
Description 4 Plastic Grille with 4 Steel Collar 4 Plastic Grille with 4 Steel Collar and Integrated Backdraft Damper 6 Plastic Grille with 6 Steel Collar 6 Plastic Grille with 6 Steel Collar and Integrated Backdraft Damper
Grille Dimensions (in inches) Grille PG-150G PG-100G Dia. 8 1/8 4 5/8 Height 1 5/8 1 1/2 Fits Duct Dia. 6 4 Fits Collars PG-150D or PGD-150DB PG-100D or PGD-150DB
Collar Dimensions (in inches) Collar PG-100D PGD-100DB PG-150D PGD-150DB Diameter 3 3/4 3 3/4 5 3/4 5 3/4 Length 3 1/4 4 1/8 4 5/8 4 1/8
PG Collar
PGD Collar
Adjustable Grilles
BOR/BOC Exhaust grilles for bathrooms, toilets and other small rooms. All models offer an adjustable central valve to regulate the airflow.
Model
D A
E 50 50 50 50
Weight (lbs) 1 1 1 1
CAR-Backdraft Damper
Backdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for positive closure. Dimensions in mm/inches Wgt. Model A B (lbs) 100 80 CAR-100 1 3 15/16 3 1/8 125 100 CAR-125 1 4 15/16 3 15/16 A 150 120 CAR-150 1 7/8 5 4 3/4 200 140 CAR-200 1 7/8 7 5 1/2 250 140 CAR-250 2 13/16 9 5 1/2 B 315 140 CAR-315 2 3/8 12 5 1/2
33
SWF-SIDEWALL Fan
Same powerful motor found in PV series fans. Low profile aesthetic design. Fully speed controllable. Built-in backdraft damper . Extended opening exhaust grille. 5 year warranty. HVI certified and cULus listed. Line includes 4 - 8 119 - 416 CFM
Fans Fans ans a s for f Life! Life e!
S&Ps V-Series Bathroom Fan by RenewAire is the best choice for exhaustonly ventilation. The V-Series improves indoor air quality and increases your homes durability by quickly exhausting contaminants and excess moisture that can cause health issues, mold growth and structural damage.
Performance The most energy efficient line of ceiling mounted ventilation fans available in North America. Aerodynamically engineered to move air with lowest power consumption and sound levels. Motors operate with the lowest heat build up for long life even when run continuously. 5 year warranty. Low air leakage dampers minimize uncontrolled infiltration. The lowest carbon footprint of leading residential ventilation brands. Construction Robust steel housing and duct collar Heat-sink motor unit Internal electrical wiring box Attractive, sturdy grille Impedance and thermal fuse electrical protection UL List for installation in tub/shower enclosures when connected to a GFCI protected branch circuit
Fans Fans ans a s for f Life! Life e!
Radiation Damper
The V-Series Radiation Dampers are designed to meet local codes that require fans installed in fire rated ceilings to be protected by dampers which are insulated against both heat and flames. These are UL Classified radiation dampers rated at 1, 2 or 3 hours of fire resistance.
V-Series Fan
Today the kitchen is the heart of our homes, its where we relax, gather and enjoy family and friends. S&P offers a range of inline fans to fit your range hood needs by offering many advantages over traditional (in hood) fans. By virtue of the remote mounting, the noise is kept further from the living space, reducing the sound level of the fan. Remote mounting also allows for a duct silencer (SIL) to be mounted between the fan and the range hood, reducing the fan noise level by another 50% or more. S&P remote fans also offer extended duty times, low maintenance, and do not detract from the homes aesthetics, unlike some unsightly roof mounted units. S&P remote fans are the clear choice for the strongest, quietest installation.
SOLVED!
Range Hood
36
Fans
Accessories
* A grease filter in the range hood is required to use an S&P Inline Fan in this application
Wall Mount Installations: 100 CFM per foot of width. Example: 48 (4 ft.) wide hood will require 400 CFM. Feet of Width CFM per Foot Air Flow [CFM] 4 x 100 400 40
48
Island Mount Installations: 150 CFM per foot of width. Example: 48 (4 ft.) wide hood will require 600 CFM. Feet of Width CFM per Foot Air Flow [CFM] 4 x 150 600
S&Ps Range Hood Exhaust Fans are California Title 24 compliant and meet ASHRAE 62.2 when installed with 3 way switch and remotely mounted speed control.
PV-SERIES Fan
Range Hood
38
Optional SIL-Silencer
RC-Roof Cap
Galvanized steel roof caps with damper flap closure. Duct sizes from 4 to 10.
Dimensions in inches/mm
Model SIL-125 5 A B
9 13/16 9 13/16 12 3/8 14 15 3/4 250 250 315 355 400
Dimensions in inches/mm
C D
700 700 700 700 700 35 7/16 35 7/16 35 7/16 35 7/16 33 7/8 900 900 900 900 860
Wgt. (lbs) 15 18 21 32 32
A
150 200 200 280 6 8 8 11
B
150 200 200 280 4 4 5
C
3 1/2 90
D
12 14 14 17 300 355 355 430 12 14 14 17
E
300 355 355 430 5 5 7
125 6 5/16 SIL-150 160 7 7/8 SIL-200 200 9 13/16 SIL-250 250 12 3/8 SIL-315 315
Wgt. (lbs) 1 1 1 1
CAR-Backdraft Damper
Backdraft dampers are designed with galvanized steel collars and have lightweight aluminum damper blades. They are spring loaded for positive closure.
Dimensions in mm/inches
Model CAR-100 CAR-125 CAR-150 CAR-200 CAR-250 A
100 3 15/16 125 4 15/16 150 5 7/8 200 7 7/8 250 9 13/16 140 5 1/2 140 5 1/2 120 4 3/4 100 3 15/16 80 3 1/8
Wgt. (lbs) 1 1 1
1 2 Model ACOP-V100 ACOP-V125 ACOP-V150 ACOP-V200 Description 4 Connector clamps (2 ea., sold in pairs) 5 Connector clamps (2 ea., sold in pairs) 6 Connector clamps (2 ea., sold in pairs) 8 Connector clamps (2 ea., sold in pairs)
Wgt. (lbs) 1 1 1 1
39
Range Hood
If you have a dryer with long or complicated duct runs, S&P offers the perfect solution to increase dryer efficiency: the PV100x Dryer Booster Fan. The PV100x has been specifically designed to handle dryer boosting applications when overcoming long or complicated duct runs. This system helps save on drying time, moisture build-up, wear and tear on your dryer, and helps save on your electric bill. The centrifugal blade design is able to overcome extreme resistance from the most challenging installations. The PV-100x offers a fully enclosed motor with Class F insulation which ensures a long, trouble free life; thus making it the right choice for enhancing the performance of your clothes dryer. The PV-100x fan is available separately or as part of a kit that includes everything necessary for a hands-free operation. Once the system is installed you will no longer waste time, energy or unnecessary wear and tear on your dryer. The next step is to select which activation best fits your needs.
SOLVED!
Pressure Switches
Pressure switches are a viable method of fan activation and a good solution for many installations. The pressure switch senses the pressure differential in the duct created by the dryer operation, thus activating the fan. NOTE Conversely, when the dryer is deactivated, the pressure The PV-100x Dryer Booster fan is suitable for use with duct runs of up to 105 linear feet of 4 rigid duct switch senses this differential and the fan is deactivated. or a maximum of 6 elbows and 80 feet. S&Ps PV-100xps utilizes a compact pressure sensor and run timer enclosed within the junction box and mounted to the fan housing. The pressure sensor is also available as an accessory.
Current Sensors
Current sensors are S&Ps preferred method of activation. They are fail-safe, as there is no maintenance required on the current sensor and theyre easy to install. The current sensing device can be installed at the outlet (where the dryer plugs into the wall) or at the circuit breaker box. When the device senses current going to the dryer, it activates the fan and vice-versa. No thought! No maintenance! Our choice!
Interlocks
Interlocks, like Current Sensors, are another fail-safe method of clothes dryer booster activation. The interlock senses when the fan is running and activates the dryer. Used as a safety feature, if the fan is not running or if there is a problem with the fan the dryer will not turn on.
All 3 activation methods are available as accessories or in the S&Ps all inclusive dryer booster kits.
SOLVED!
Gasoline, automotive exhaust fumes, paint, fertilizer, pesticides and other potentially harmful products are present in most garages and the effect on the quality of air inside the home is undoubtedly compromised if not properly addressed. Keep the hazardous fumes in your attached garage from entering your home and harming you and your family with the SWF Series fans. S&Ps Garage Ventilation solutions help keep the contaminants in your garage from harming you and your family! The SWF Series outdoor rated exterior housing provides easy access from the outside of a building or dwelling. This makes the SWF a great solution for installations where attic space or easy indoor access is difficult and not suitable for traditional PV style in-line mounting. The Sidewall Fan Series (SWF) of direct drive centrifugal ventilation fans consists of five model sizes: 4 through 8. All models are designed for direct connection in-line with standard diameter round ducting. Airflow performance values range from 119-416 CFM. You can also use S&P TD-MIXVENT, TD-SILENT or PV-POWERVENT for your garage ventilation needs.
TD-MIXVENT
TD-SILENT
PV-POWERVENT
41
Garage
Everyday activities such as showering, cooking, doing laundry, even breathing are just a few ways that moisture is generated in your home (one gallon per person, everyday). Moisture that is trapped in your home can lead to structural damage. Signs of structural damage include heavy condensation on windows, water damage on window sills and molds forming in cold corners of the home.
IAQ
Whether you have a new home under construction or an existing home needing a ventilation upgrade, S&P provides powerful, quiet blowers in its TR (total recovery) Series for all climates. You can enjoy ample air exchange without the objectionable noise associated with lower quality products. If you want the best whole house approach to efficient and effective ventilation, S&Ps TR Series makes your choice simple.
42
SOLVED!
To protect the two most valuable investments of your life, your home and your family, improving indoor air quality is key. With S&Ps TR (total recovery) Series for all climates, stale room air is exhausted and fresh outdoor air is brought back into the house. These two air streams are directed through a highly developed air-to-air energy exchange core. The air streams are physically separated by many layers of plates so there is no mixing or contamination of the fresh air. The plates are made of an engineered resin material that simultaneously transfers heat by conduction and humidity by attracting and moving water vapor from one air stream to the other. S&Ps TRs moderate extremes in both temperature and humidity, creating a comfortable indoor environment. The unique moisture transfer capability of the S&P core also eliminates condensation and frost build up in most applications. Unlike other ERVs on the market no mechanical or electrical defrost systems are needed, which means higher heat recovery efficiencies, easier installation and more reliable operation.
The CORE
Efficient transfer of heat and moisture No liquid is accumulated; no drain pan or defrost mechanism is required! Industry best 10-year warranty
Contaminated air is exhausted from your home, while the static plate core regulates extremes in humidity
43
IAQ
Q: A: Q: A: Q: A:
IAQ
44
Energy Recovery Ventilators (ERV) and Heat Recovery Ventilators (HRV) both moderate extremes in ventilation air temperature so what is the difference? ERVs Transfer BOTH heat AND humidity Use enthalpic core S&Ps TR is an ERV HRVs Transfer ONLY heat Use aluminum core or simple plastic cores
Can ERVs be used in climates subject to cold winters? Yes! Because ERVs transfer both heat and humidity they are the perfect choice for any climate. In the winter ERVs: Warm outdoor air close to room temperature Use heat that would otherwise be lost with the exhaust air. Transfer water vapors to moderate extremes in humidity levels Help prevent moisture damage or over-drying of the home.
Why are ERVs better than HRVs? HRVs and ERVs are similar in that they both: Improve Indoor Air Quality Moderate extremes in ventilation temperature Use heat that would otherwise be lost with the exhaust air in the winter Provide necessary fresh air while pre-cooling in the summer ONLY ERVs have the ability to transfer water vapors or moisture so they: Help prevent over-drying of the home in colder seasons Lessen the demand on the air-conditioning system in warmer seasons Are typically 3x more energy efficient in the summer than products (or units) that transfer only heat (HRVs)
Q: A:
Why is S&Ps Series TR the Ultimate ERV? S&Ps TRs provide the same benefits as other ERVs on the market. Major Series TR advantages include: More heat transfer than most HRVs More humidity control than other plate exchangers Simplicity and positive airstream separation not offered by wheel type ERVs 10-year core warranty
S&P TR draws room air from places that are to be exhausted to outside.
S&P TR moderates extremes in both heat and humidity year round. Air polluter
Use one of S&Ps Inline Centrifugal fans (SWF shown) for a silent Range Hood Exhaust.
After transferring its heat inside the TR, stale air is exhausted outside.
Return-air plenum
Outside-air intake draws fresh air into the TR, where it is tempered before it enters the returnair plenum.
S&P TR draws room air from air handler return air duct system.
To get the most efficient and effective general ventilation system available use a TR with S&Ps exclusive TD-MIXVENT inline fans for bathroom exhaust.
Energy efficient homes can trap indoor air pollutants. Air polluter
Use one of S&Ps Inline Centrifugal fans (SWF shown) for a silent Range Hood Exhaust.
Outside-air intake draws fresh air into the TR, where it is tempered before it enters the returnair plenum.
After transferring its heat inside the TR, stale air is exhausted outside.
45
IAQ
SFM - Percentage Timer Control with Furnace Interlock Alternate primary control for TR70, TR130, TR200 and TR300 Wires to TR unit and either thermostat or furnace control to turn on furnace blower Six wire, low voltage connection Meets ASHRAE 62.2 continuous ventilation standards SHW-20 - Dehumidistat Rotary dial dehumidistat Turn the dial to set desired humidity level Designed for convenient installation in bathrooms, kitchen or laundry room Dehumidifies when inside air is more humid than the set point Caution: the outside air must be less humid than the indoor air for this to work.
If you home is up to: 1500 Sq. Ft. you need a TR70 2700 Sq. Ft. you need a TR130 4000 Sq. Ft. you need a TR200 6000 Sq. Ft. you need a TR300
Terms to Know
Sensible Heat The amount of energy involved in raising or lowering the temperature of air not including any energy required to cause water vapor to change state. Latent Heat The amount of energy associated with the humidity (or water vapor content ) of an air stream. A drier air stream contains less latent heat and will impose a smaller latent load on the air conditioner. Enthalpy The total amount of energy contained in air, the sum of sensible and latent heat. Balanced Ventilation A ventilation strategy using both an exhaust air blower and a supply or make-up air blower that does not pressurize or de-pressurize a building. Air-to-Air Heat Exchanger Generic term for technologies designed to transfer heat -- and sometimes moisture -- between two air streams. Heat Recovery Ventilator HRV An air-to-air heat exchanger that transfers sensible heat only; no humidity (latent heat) transfer occurs between the two air streams. Energy Recovery Ventilator ERV In Cold Weather, some of the humidity in the inside air is recovered along with its latent energy. Non-enthalpic heat recovery systems lose that latent energy.
47
IAQ
Soler & Palau USA 6393 Powers Ave. Jacksonville, FL 32217 p: 800.961.7370 f: 800.961.7379 www.solerpalau-usa.com
Soler & Palau Canada 5600 Ambler Drive Mississauga, ON L4W 2K9 p: 866.733.0233 f: 866.358.5346 www.solerpalaucanada.com
48