Anda di halaman 1dari 5

Customer Name: for Vietnam Project : VN-YI2013-YI-120110-A Concept of Network Architecture

Analog video 8000HP* cluster


Coax

Hecto QAM

Digital video 30km ring

8000HP* cluster

Transport Network HFC Tx Platforms HSD

24000HP

O-Hub Optical Nodes

HSD

8000HP* cluster
Coax

Digital Headend

HFC Rx Platforms

Hub

Notes *) Size of service area in respect to distances and home passed are indicated as design assumption only

Prepared by Yuri Iofin Tel: 408-542-2690

February 9, 2012 Email: yuri.iofin@harmonicinc.com

Page 1

Customer Name: for Vietnam Project : VN-YI2013-YI-120110-A Downstream


SPL7110C-Exx
BC+NC E01 E02 1x8 WDM MUX E03 E04 E05 E06 E07 E08

8000HP cluster - Phase 1


Collector Node
3 km 22.5 km 5.7dB
1x8 WDM MUX 17 E01 E02 E03 E04 E05 E06 E07 E08 8 4 2 4

(8) Nodes HLN3142C


NRM3111A
2.4 RF

RF A/B SWITCH
8

NOA7017-GF HWM1108S-10E01

SPL7110C-Exx
BC+NC E01 E02 1x8 WDM MUX E03 E04 E05 E06 E07 E08 9.5

30 km ring
1x8 WDM MUX

E01 E02 E03 E04 E05 E06 E07 E08

4 RF

7.5 km 1.9 dB

Notes
NWM3108S-10E01 1. Attenuation at 1550nm and DWDM is 0.25dB/km

Upstream
NTM3249-CXX
C21

3 km
RF 7

22.5 km 5.7dB
1x16 WDM MUX 8 C35

HRR4104
8

C21

1x16 WDM MUX

HOS7100 NWM3116A-20C21
C53 8

C35

-1.8 C53 -3.5

30 km ring
C21 1x16 WDM MUX 8 C35 RF

-7.5

HWM1116A-20C21

7.5 km 1.9 dB

C53

Hub

O-Hub Service design parameters


Downstream Size of Service area Number of Service groups Size of Service group Contention Rate Number of NC channels Cannel bandwidth NC Bandwidth capacity Modulation format Data rate capicity Data rate per user HP 8000 1 8000 0.1 12 8 96 64QAM 432 0.5 Upstream Size of Service area Number of Service groups Size of Service group Contention Rate Number of NC channels Cannel bandwidth NC Bandwidth capacity Modulation format Data rate capicity Data rate per user HP 8000 8 1000 0.1 6 3.2 19.2 16QAM 55.2 0.6

MHz MHz Mbps Mbps

MHz MHz Mbps Mbps

Prepared by Yuri Iofin Tel: 408-542-2690

February 9, 2012 Email: yuri.iofin@harmonicinc.com

Page 2

Customer Name: for Vietnam Project : VN-YI2013-YI-120110-A Downstream


SPL7110C-Exx
BC+NC BC+NC E01 E02 1x8 WDM MUX E03 E04 E05 E06 E07 E08 E01

8000HP cluster - Phase 2


Collector Node
3 km 22.5 km 5.7dB
1x8 WDM MUX 13 4 E02 E03 E04 E05 E06 E07 E08 8 4 8

(8) Nodes HLN3142C


NRM3111A
2.2 RF

RF A/B SWITCH

NOA7017-GF HWM1108S-10E01

SPL7110C-Exx
BC+NC BC+NC E01 E02 1x8 WDM MUX E03 E04 E05 E06 E07 E08 9.5

30 km ring
1x8 WDM MUX

E01 E02 E03 E04 E05 E06 E07 E08

4 RF

7.5 km 1.9 dB NWM3108S-10E01

Notes
1. Attenuation at 1550nm and DWDM is 0.25dB/km

Upstream
NTM3249-CXX
C21

3 km
RF 7

22.5 km 5.7dB
1x16 WDM MUX 8 C35

HRR4104
8

C21

1x16 WDM MUX

HOS7100 NWM3116A-20C21
C53 8

C35

-1.8 C53 -7.5 -3.5

30 km ring
1x16 WDM MUX

C21

8 C35 RF

HWM1116A-20C21

7.5 km 1.9 dB

C53

Hub

O-Hub Service design parameters


Downstream Size of Service area Number of Service groups Size of Service group Contention Rate Number of NC channels Cannel bandwidth NC Bandwidth capacity Modulation format Data rate capicity Data rate per user HP 8000 2 4000 0.1 16 8 128 64QAM 576 1.4 Upstream Size of Service area Number of Service groups Size of Service group Contention Rate Number of NC channels Cannel bandwidth NC Bandwidth capacity Modulation format Data rate capicity Data rate per user HP 8000 8 1000 0.1 8 3.2 25.6 16QAM 73.6 0.7

MHz MHz Mbps Mbps

MHz MHz Mbps Mbps

Prepared by Yuri Iofin Tel: 408-542-2690

February 9, 2012 Email: yuri.iofin@harmonicinc.com

Page 3

Customer Name: for Vietnam Project : VN-YI2013-YI-120110-A Downstream


SPL7110C-Exx
BC+NC BC+NC BC+NC BC+NC E01 E02 1x8 WDM MUX E03 E04 E05 E06 E07 E08 E01

8000HP cluster - Phase 3


(16) Nodes HLN3142C
NRM3111A 3 km 22.5 km 5.7dB
1x8 WDM MUX 11 4 E02 E03 E04 E05 E06 E07 E08 4 16 16 0.2 RF

Collector Node

RF A/B SWITCH

NOA7017-GF HWM1108S-10E01

SPL7110C-Exx
BC+NC BC+NC BC+NC BC+NC E01 E02 1x8 WDM MUX E03 E04 E05 E06 E07 E08 9.5

30 km ring
1x8 WDM MUX

E01 E02 E03 E04 E05 E06 E07 E08

16

7.5 km 1.9 dB NWM3108S-10E01

4 RF

16

Notes
1. Attenuation at 1550nm and DWDM is 0.25dB/km NTM3249-CXX

Upstream
HRR4104 22.5 km 5.7dB
1x16 WDM MUX C21

3 km
RF 7

16

C21

1x16 WDM MUX

HOS7100 NWM3116A-20C21
C53 16 C21

16

-1.8 C53 -3.5

30 km ring
HWM1116A-20C21
1x16 WDM MUX

16

-7.5

7.5 km 1.9 dB

C53

RF

16

Hub

O-Hub Service design parameters


Downstream Size of Service area Number of Service groups Size of Service group Contention Rate Number of NC channels Cannel bandwidth NC Bandwidth capacity Modulation format Data rate capicity Data rate per user Upstream 8000 Size of Service area 4 Number of Service groups 2000 Size of Service group 0.1 Contention Rate 24 Number of NC channels MHz 8 Cannel bandwidth MHz 192 NC Bandwidth capacity 256QAM Modulation format Mbps 1216.0 Data rate capicity Mbps 6.1 Data rate per user HP HP 8000 16 500 0.1 12 3.2 38.4 64QAM 172.8 3.5

MHz MHz Mbps Mbps

Prepared by Yuri Iofin Tel: 408-542-2690

February 9, 2012 Email: yuri.iofin@harmonicinc.com

Page 4

Customer Name: for Vietnam Project : VN-YI2013-YI-120110-A Downstream


SPL7110C-Exx
BC+NC BC+NC BC+NC BC+NC BC+NC BC+NC BC+NC BC+NC E01 E02 1x8 WDM MUX E03 E04 E05 E06 E07 E08 E01

8000HP cluster - Phase 4


(16) Nodes HLN3142C
NRM3111A 3 km
2 0.2 RF

Collector Node

22.5 km 5.7dB
1x8 WDM MUX

E02 E03 E04 E05 E06 E07 E08 2 16 E01 E02 2 8

RF A/B SWITCH

NOA7017-GF

SPL7110C-Exx
BC+NC BC+NC BC+NC BC+NC BC+NC BC+NC BC+NC BC+NC E01 E02 1x8 WDM MUX

30 km ring
HWM1108S-10E01

E04 E05 E06 E07 E08

1x8 WDM MUX

E03

E03 E04 E05 E06 E07 E08 2 RF 8

7.5 km 1.9 dB

16

NWM3108S-10E01

Notes
1. Attenuation at 1550nm and DWDM is 0.25dB/km NTM3249-CXX
C21

Upstream
HRR4104 22.5 km 5.7dB
1x16 WDM MUX

3 km
RF 7

16

C21

1x16 WDM MUX

HOS7100

NWM3116A-20C21

C53 16

16

-1.8 C53 -3.5

30 km ring
C21 1x16 WDM MUX

HWM1116A-20C21

16

-6.7

7.5 km 1.9 dB

C53

RF

16

Hub Service design parameters


Downstream Size of Service area Number of Service groups Size of Service group Contention Rate Number of NC channels Cannel bandwidth NC Bandwidth capacity Modulation format Data rate capicity Data rate per user

O-Hub
Upstream 8000 Size of Service area 8 Number of Service groups 1000 Size of Service group 0.1 Contention Rate 32 Number of NC channels MHz 8 Cannel bandwidth MHz 256 NC Bandwidth capacity 256QAM Modulation format Mbps 1621.3 Data rate capicity Mbps 16.2 Data rate per user HP

HP

MHz MHz Mbps Mbps

8000 16 500 0.1 16 3.2 51.2 64QAM 230.4 4.6

Prepared by Yuri Iofin Tel: 408-542-2690

February 9, 2012 Email: yuri.iofin@harmonicinc.com

Page 5