Anda di halaman 1dari 38

General Equipment

CHAMBER FURNACES
Standard features: 1100C maximum operating temperature 6, 14 or 23 litre chamber volumes Tilt forward, drop down door with air gap to minimize external temperature Carbolite 301 controller, with single ramp to set-point facility Delayed start & process timer function as standard Vacuum formed, low thermal mass insulation Hard ceramic hearth fitted as standard Ventilated via top mounted ceramic chimney

ELF

GENERAL PURPOSE CHAMBER FURNACES


Standard features: 1100C, 1200C or 1300C maximum operating tempera ture 5, 13 or 23 litre chamber volumes Up & away door keeps heated surface away from the user Carbolite 301 controller with single ramp to set-point facility Delayed start & process timer function Hard wearing alumina element carriers, furnace entrance & hearth Energy efficient low thermal mass insulation Free radiating wire wound elements pitched for optimum uniformity Easy access to elements & controls simplifies maintenance & servicing CWF

HIGH TEMPERATURE SINGLE ZONE TUBE FURNACE


Standard Features: 1500C & 1600C maximum operating temperatures Using worktubes of 60 or 90mm outer diameter Accepts worktubes with 180, 450 or 610mm heated tube length Silicon carbide heating elements Horizontal configuration Carbolite 301 controller, with single ramp to set-point facility Delayed start / process timer function as standard

STF

General Equipment

Freeze Dryer ALPHA 1-2 LDplus


What is freeze drying (Lyophilisation)? Freeze drying means: Extraction of water from frozen material. The drying process takes place by avoiding the liquid state through sublimation, i. e. direct conversion from ice to vapor. This happens under vacuum and the temperature in the product is normally less than -10C The freeze dryer ALPHA 1-2 LDplus is suitable for drying of e. g. bacteria and virus cultures, blood plasma, serum fractions, antibodies, sera, vaccines and pharmaceutical products such as chloramphenicol, streptomycin, vitamins, ferments as well as plant extracts for biochemical tests.

Specification: Ice condenser

: capacity max. 2.5 kg : performance: max. 2 kg / 24 h : temperature: approx. 55oC : width: 315 mm : height: 345 mm, dept: 460 mm : approx. 28 kg : according to DIN 45635:49 dB(A) : 230 v / 50Hz (others upon request) : 1,2 kVA : 5A : 6,3 A : Climate category: SN +10oC to +25oC, higher temperatures upon request)

Physical data (without vacuum pump) Dimensions of the unit (ind. Vacuum flange connection) Weight Noise emissions Electrical connection Power consumption Max. current Fuse protection Ambient temperature

Consist of : Alpha 1-2 / LD Plus 101021) Vacuum Pump RZ2 125302) Vacuum hose Vacuum sensor TPR265 Exhaust filter Base plate 120890) Acrylic Chamber 121455) 8 rubber valves 3 shelves with rim 120893) 8 round flasks 500 ml (cat #: (cat #: (cat #: 125702) (cat #: 125479) (cat #: 125501) (cat #: (cat #: (cat #: 121860) (cat #: (cat #: 127360)

General Equipment

ROTATIONAL VACUUM CONCENTRATOR FOR LABORATORY


RVC SERIES
The Christ RVC-series is well structured in size and combination with different cooling traps and vacuum pumps. This gives the customer a maximum benefit for every application. Examples for multiple applications: Efficient concentration of DNA/RNA-samples, proteins etc. BioTech and Genetic Engineering Sample preparation in HPLC, GC, MS, Electrophoresis ... Isolation and synthesis of natural compounds Storage and handling of drugs (chemical libraries) Combinatorial Chemistry High-Throughput-Screening (HTS)

RVC 2-25 CD

Rotational-Vacuum-Concentrator RVC 2-25 CD the mid-size concentrator: all-purpose table-top cencentrator for the routine concentration of
larger sample volumes rotor capacity 108 x 1,5/2,2 ml tubes up to 2 x microtiter-plates standard acrylic glass cover, optional stainless steel/glass compound cover with window (corrosion proof, e. g. for DCM/ACN) chemical resistant diaphragm pumps (2 m3/h suction capacity, 9 mbar final vacuum), standard, vacuum systems with lower vacuum and vacuum controls, optional optional combination with cooling traps (2 or 4 litres) for increased evaporation

General Equipment

Ultrasonic Cleaners Baths


Elmasonic P
The most professional way to use ultrasound
Digital displays, self-explanatory operation, clear indication of all

parameters, set and actual values at a glance. Two different ultrasonic frequencies in one unit (frequency can be changed during operation): 37 kHz - for coarse contaminations, for dissolving, blending, dispersing and degassing 80 kHz noise-reduced operation, ideal for quiet work areas, prolonged ultrasonic cleaning cycle, perfect for the cleaning of hollow spaces, e.g. capillaries 7 special ultrasonic features (Normal, Pulse, Sweep, Degas, Power rasonic Operation up to 140% power control, Pause, Auto Start)

40 kHz Ultrasonic Frequency


Transonic type Outer Dimensions (mm) Inner Dimensions (mm) Tank capacity Drain duct V4A () Power consumption total (W) Ultrasonic Frequency Heating power (W) Sweep Pulse P 30 H 300x179x221 240x137x100 2.75 L 3/8 320/300 37/80 kHz 200 integrated activatable

P 60 H 365x186x271 300x151x150 5.75 L 3/8 580/550 37/80 kHz 400 integrated activatable

P 70 H 568x179x221 505x137x100 6.9 L 3/8 820 37/80 kHz 600 integrated activatable

P 120 H 365x278x321 300x240x200 12.75 L 3/8 1130 37/80 kHz 800 integrated activatable

P 180 H 390x340x321 327x300x200 18 L 3/8 1130 37/80 kHz 800 integrated activatable

P 300 H 568x340x321 505x300x200 28 L 3/8 1580 37/80 kHz 1200 integrated activatable

Elmasonic S Series Offers...


Sweep function for an optimized sound field distribution in the

cleaning liquid by frequency modulation


Degas function for the efficient degassing of the cleaning liquid

and for laboratory purposes


Electronic timer from 1 to 30 minutes Plastic carrying handles

Parameter Tank Volume Internal dimension Ultrasonic frequency Heating Power Drain duct diameter

S40H 4.25 lt 240x137x150mm 37 kHz 200 W 3/8

S60H 5.75 lt 300x151x150mm 37 kHz 400 W 3/8

S70H 6.9 lt 505x137x100mm 37 kHz 600 W 3/8

S100H 9.5 lt 300x240x150mm 37 kHz 600 W 3/8

S300H 28 lt 505x300x200 37 kHz 1200 W 3/8

General Equipment

RESEARCH PLUS PIPETTE


Available Volume: Adjustable: 0.1-2.5 L, 0.5-10 L, 2-20 L, 10-100 L, 20200 L, 30-300 L, 100-1,000 L, 0.5-5 mL, 1-10 mL. Multichannel: 0.5-10 L, 10-100 L, 30-300 L. Fixed volume: 10 L, 20 L, 25 L, 50 L, 100 L, 200 L, 250 L, 500 L, 1,000 L

Ultra light pipette with highest precision and accuracy, low operating force, ultimate ergonomics and flexibility, 4 digits volume display with magnifying shape, fully autoclavable, resistance to chemical, thermal and mechanical stress.

EPPENDORF ep T.I.P.S
Choose from a wide range of ep T.I.P.S. : Purity level (Eppendorf quality, Eppendorf PCR clean, Eppendorf biopur), filter (standard or dual filter), and packaging (box, reloads, set, singles, or rack).

MULTIPETTE PLUS, STREAM & XSTREAM


Positive displacement dispenser: Ideal for dispensing volume in long series, contamination-free (eliminates aerosol formation) application eg. PCR application, toxic, infectious or radioactive liquids, aggressive liquids (e.g. concentrated acids), also ideal for problematic liquids such as viscous, high vapor pressure and high/low density liquid.

VARISPENSER, VARISPENSER PLUS, TOP BURET, EASYPET

General Equipment

MICROLITER 600, 700, 800 and 900 Series 2.5 L to 500 L This type of syringe*, for use with liquids, incorporates a stainless steel plunger that is individually fitted to its matching syringe barrel. The plunger is not interchangeable or replaceable. 600 Series 2.5 L and 5 L Reinforced plungers prevent plunger bending Rugged, durable and long lasting 700 Series 5 L to 500 L Economical; great for chromatography Also available: ground glass tip (luer tip, LT) termination 800 Series 5 L to 250 L Reinforced plungers Plunger stop prevents plunger blow-out 900 Series 5 L and 10 L Reinforced plungers Perfect for students: rugged and durable MODIFIED MICROLITER 7000 Series 0.5 L to 5 L Positive displacement syringe has a tungsten plunger wire that travels inside the needle The needle essentially acts as the glass syringe barrel; no dead volume Replaceable plunger wire and needle

Syringe size 0.5-5 l 2.5-5 l 5-10 l 5-250 l 10-250 l 10-500l 1-100 ml

600 series

700 series

800 series

900 series 7000 series 1000 series 1700 series 1800 series

General Equipment

HAMILTON SPECIAL SYRINGE


Super Syringes 5 L to 2 L For air sampling, preparing gas standards; or calibrating reservoirs, pneumographs, and spirometers. Used in industries such as: mining, chemical production, grinding and mineral processing. Syringe barrel is made of a clear acrylic material. Purge & Trap Syringes 5 mL and 25 mL These syringes are designed for the analysis of drinking water Samples according to EPA purge and trap concentration techniques.

Carbon Analyzer Syringes 50 L to 250 L For water analysis with Total Organic Carbon (TOC) analyzers. Wetted parts are stainless steel and borosilicate glass. Syringes have a metal luer tapered hub cemented over a MICROLITER 700 Series N syringe. The luer hub fits precisely into the inlet of a total carbon analyzer.

PB600 Repeating Dispensers 10 L to 10 mL Consistently dispense sample up to 50 times with the push of a button. The repeating dispenser works with MICROLITER or GASTIGHT syringes from 10 L to 10 mL.

SampleLock Syringes 50 L to 100 mL Lock your sample in the SampleLock syringe with the easy-to-use twist valve. An internal standard can be injected through the valve port into samples contained in the SampleLock syringe. Also, pre-pressurize gaseous samples prior to GC injection. The positive rear plunger stop prevents loss of sample and plunger blowout at elevated pressures.

Digital Syringe .5 L to 500 L


The only N.I.S.T. traceable, calibrated syringe device available Comes completely calibrated with its own Certificate of Calibra tion Easy-to-read LCD screen displays volume dispensed within 0.5 % of the syringe volume Used with Hamilton syringes with total volumes of 0.5 to 500 L
OTHER SYRINGES AVAILABLE Please call us to request any of the following syringe: LIFE SCIENCE SYRINGES, CHROMATOGRAPHY SYRINGES, INSTRUMENT SYRINGES

General Equipment

COOLING CIRCULATORS
Refrigerated Heating Bath with air-cooled refrigerating unit. Consisting of isolated cooling bath made of stainless steel with immersion thermostat. Pump and wetted parts made from stainless steel or highresistant plastics.
MPC-Controller: Modern and easy to use microprocessor controller with a large temperature display. Limited to essential functions only: * Large temperature display * LED indicators for pump, cooling and heating * Simple operation using only 3 keys

CC-Pilot:
controller with new innovative E-grade technology for extended functionality without swapping the controller. An activation code is entered via the control panel and the proven Plug & Play technology for professional service. The bright TFT display shows all the process relevant data. User friendly interface: The functions self-explanitory and are listed in alphabetical order in each of the selected languages. Easy-Control: Is virtually identical to the unistats. Display resolution in the basic version is 0,1K. Set point limits, optical and acoustical alarm, mains failure automatic function. Sensor calibration, control via RS232 interface and Com.G@te Namur (option) e.g. for connection to a process control system, remote control via data cable.

K12-mpc-NR

K12-cc-NR

Bath Heating Temp. Range Power o ( C) (kW) Model K12-cc-NR K12-mpc-NR K15-cc-NR K15-mpc-NR K20-cc-NR K20-mpc-NR K25-cc-NR K25-mpc-NR -20...200 -20...200 -20...200 -20...200 -30...200 -30...200 -30...200 -30...200 2 2 2 2 2 2 2 2

Pump Data max. max. Pressure Suction Vol (ltr) (l/min) (l/min) 12 12 15 15 20 20 25 25 27 20 27 20 27 20 27 20 25 17 25 17 25 17 25 17

Cooling Powet (kW) at

Opening (mm) 290x152 290x152 290x152 290x152 290x329 290x329 290x329 290x329

Depth (mm) 150 150 200 200 150 150 200 200

0o C

-10oC

-20oC

Dimensions (WxDxH) (mm) 350x560x430 350x560x430 350x560x430 350x560x430 350x555x615 350x555x615 350x555x615 350x555x615

0.2

0.12 0.12

0.05 0.05 0.05 0.05 0.16 0.16 0.16 0.16

0.2 0.2 0.2 0.35 0.35 0.35 0.35

0.12 0.12 0.27 0.27 0.27 0.27

Minichiller-NR
Specification : Operating temperature range-20...40 C Temperature adjustment ; digital Temperature indication : digital Internal temperature sensor : Pt 100 Resolution of display : 0.1 K Temperature stability at -10C : 0.2 K Safety classification : Class I / NFL Cooling power at 15C : 0.3 kW at 0C : 0.2 kW at -10C : 0.14 kW at -20C : 0.07 kW Refrigeration machineair-cooled, natural refrigerant Refrigerant : R290 Refrigerant quantity 0.04 kg

General Equipment

MAGNETIC STIRRER & HOT PLATE


Single Point Magnetic Stirrer
Picture

Model Max volume Speed range Plate Advantage

Lab disc 0.8 L 15-1500 rpm polyester Thin12mm; Automatic positive & negative rotation Solenoid drive

C-MAG MS 7 10 L 1001500 rpm Ceramic Strong motor Anti rust Control panel is higher, anti-splash

Midi MR digital 50 L 0-1000 rpm stainless steel Big volume mix Digital speed display Timer function 056min).

Single Point Heating Magnetic Stirrer

Picture

Model Max volume Speed range Max temp. Plate

C-MAG HS 7 10 L 100-1500 rpm 500 oC Ceramic

RCT basic 20 L 50-1500 rpm 310 oC Aluminium alloy PT1000 sensor Digital temp. display Error code Membrane

RET basic 20 L 50-1700 rpm 340 oC Stainless steel

RET control/t 20 L 50-1200 rpm 340 oC Stainless steel

Advantage

Strong motor Anti-corrosion plate Control panel is higher, antisplash

PT1000 sensor Ultra-fast heating speed Protection membrane

Ultra-fast heating speed Protection membrane Able be PC controlled Timer function

General Equipment

Multi-point Heating Magnetic Stirrer


Silicon Plate Single point max volume : 400 ml Speed Range : 0-1100 rpm Max Plate Temp : 120 C Max Medium temp. (dep. On vessel ) : 70 C

RT 5 : 5 Stirring posisions

RT 10 : 10 Stirring posisions

RT 15 : 15 Stirring posisions

SHAKER
Model MTS 2/4 digital circular KS130 basic/control orbital KS260 basic/ control orbital HS260 basic/ control Reciprocating HS501 digital

Shaking movement Orbital diameter Max weight

Reciprocating

3 mm

4 mm

10 mm

20 mm

30 mm

2 or 4 microtiter plates scale 0-1100 rpm

2 kg

7.5 kg

7.5 kg

15kg

Speed display Speed range Others

LED/Digital 80-800 rpm KS130 control: PC Control

LED 20-500 rpm KS260 control: PC Control

LED 20-300 rpm HS260 control: PC Control

Digital 0-300 rpm

MTS 2/4 digital

KS130 basic HS260 Control

General Equipment

Vortex Mixer VORTEX Genius 3 (VG 3)


Specification: Speed : 5002500 RPM Orbital diameter : 4mm Speed adjust : Analog Speed display : scale 0 6 Operation mode : Continuous or Touch mode

INCUBATOR SHAKER KS 4000 i control & KS 4000 ic control


Specification: Orbital diameter : 20 mm Max. shaker weight (with attachment) : 20 kg Power consumption (at 230 V) : 1.120 W Speed range : 10 500 rpm Heater power : 1.000 W Temperature range : Room Temperature + 5 C to 80 C Temperature stability (200 ml H2O at target T = 37 C, RT 25 C) : 0,1 K Timer switch (select minutes/hours) : / 1 s - 999 h Speed, time and temperature display : digital All functions can be controlled and documented using the labworldsoft software KS 4000 ic control is with built in cooling coil for connecting an external cooling unit e.g. KV 600

ULTRA TURRAX TUBE DISPERSER ULTRA TURRAX TUBE DRIVE (UTTD) control Workstation
The new control version offers the following additional advantages: - USB interface for experiment control and documentation - Collecting tray for protection against leaking liquids - Simple and precise menu navigation thanks to the OLED display - Programmable sample conditions (library) - Adjustable reverse operation - Turbo-button for short time intensive mixing, homogenizing or grinding - Multilingual menu - Digital display for all functions Technical data Rating input: 20 W Rating output: 17 W Speed range: 400-6000 rpm/8000 rpm Timer: 10 s-30 min Dimensions (WxDxH) : 122x178x48 mm
UTTD control Workstation Included with delivery : ULTRA-TURRAX Tube Drive control - 1 ST-20 Tube with stirring device 2 DT-20 Tube with rotor-stator element 1 BMT-20 G / S Tube for grinding with glass (G) or stainless steel balls (S) 1 Removal hook for removal of rotor-stator 1 Power supply 1

General Equipment

DISPERSERS
Model Volumeml) T18 11500ml T25 12000ml

Speed range

350024000 rpm Scale

340024000 rpm Digital

Speed display

Accessories : Dispersing elements, Stands: R 1825, R 1826, R1827, R 182 Boss head clamp, RH3 Strap Clamp. T18 Basic T25 Digital
Please contact our sales for detail information of Dispersing elements

OVERHEAD STIRRER
Mechanical overhead stirrers High torque, large quantity stirrer Fit for continuous and strong mix RW 28 basic Model Max. quantity Max. viscosity Max. torque Speed range Advantage RW 20 digital 20 L 10,000 mPas 150 Ncm 60-2000 rpm Strong motor; High & Low speed Low speed for high viscosity, high speed for strong stirring IP20 RW 28 basic 80 L 50,000 mPas 900 Ncm 60-1400 rpm Strong motor; High & Low speed Low speed for high viscosity, high speed for strong stirring IP42 RW 47 D 200 L 100,000 mPas 3000 Ncm 57-1300 rpm Strong motor; High & Low speed Three-phase motor; High IPIP54

General Equipment

Electronic overhead stirrers


Middle torque, volume Microprocessor control, digital display, torque trend display, RS232 used to connect with computer. Model RW16 basic 10 L 10,000 mPas 40 Ncm Eurostar digital 20 L 10,000 mPas 30 Ncm Eurostar Power basic 40 L 50,000 mPas 60 Ncm Eurostar Power control-visc 40 L 50,000 mPas 60 Ncm

Max Quant. Max visc.

Max torque

Speed (rpm)

40-1200

50-2000

50-2000

50-2000

Advantage

Small footprint

Micro-processor control

Power

Relative torque display; RS232

RW16 Basic

Eurostar digital

Eurostar Power basic

Eurostar Power contro-visc

EUROSTAR power control-visc Package, consist of: EUROSTAR power control-visc, R 1342 Propeller stirrer, R 1826 Plate stand , R 182 Boss head clamp, RH 3 Strap clamp

General Equipment

ROTARY EVAPORATOR
RV 10 basic Dimensions (W x D x H) 410 x 405 x 395 mm Speed: 20 - 270 1/min; Smooth start Moves right and left in interval operation for the drying process Motorised lift (stroke 140 mm) with "safety stop" function, if the power cuts out the evaporator piston is automatically lifted out of the heating bath, adjustable end position recognition Timer function for time lapse controls Water - oil heating bath 20 C 180 C / stand alone operation possible / Heats up quickly because of optimised bath volumes 1 Liter vertical glassware (standard) Digital speed display Temperature display scale Digital speed and temperature display Infrared interface for data transfer from the heating bath to the drive unit RS 232 interface for PC remote operation with labworldsoft Integrated vacuum controller Integrated cooling water monitoring Integrated solvent library, extendible by the client; Distillation specific parameters stored for standard distillation Automatic distilling - Automatic boiling point recognition Automatic transfer of measurements and distillation type with one key press; Distillation specific parameters stored for standard distillation / Integrated evaporator library USB interface Colour graphic display, Multiple languages Cooling water and heating bath switched off automatically after the end of the test x x x x RV 10 digital x x x x RV10 control x x x x

x x x x x

x x x x x x x

x x x x x x x x x x x x

x x x

All V (Vertical) and VC (Vertical Coated) packages come standard with: Drive system Hose connectors Glassware clamps, Woulf flask Heating bath (180C) Vertical (coated or uncoated) glass condensor 1L distilling and receiving flasks, vapor tube, seal RV 10 Basic V/VC RV 10 Digital V/VC

RV 10 control all in one package is your best option

MPC105Tp Vacuum Pump RV 10 Control V

KV600 Chiller

General Equipment

AUTOMATIC TITRATOR for TAN/TBN MEASUREMENT (TOUCH SCREEN) Model : AT-610 ST


SPECIFICATION:
Detection range : 1) Potentiometric : -2000mV~+2000mV 2) pH : 0.00~14.00pH 3) Temperature : 0~100C Titration mode : Blank, Auto Titration, Auto Intermit, Intermit Petroleum Titration COD control and Stat control-Total 7 modes 50 Standard methods, 10 Combined methods Potentiometric (acid/base, redox, precipitation), Photometric, Polarization and Conductometric titrations, Full titration (Auto EP detection)/ EP Stop/ Level Stop Level Stop / Learn Titration Direct operations on a touch screen, Display : 1) 8-inchi color LCD with 256 colors (800 x 600-dot resolution) 2) Simultaneous 2-channel display (even for a Karl Fischer Moisture Titrator) *2 Calculation: Concentration, Statistical data ( Mean, SD and *3 RSD ) Ambient conditions : 1) Temperature 5-35C 2) Humidity : Below 85% RH (No condensation) Power consumption : 100-120V AC / 200-240V AC 10%, 50/60 Hz, 20W Dimensions and Weight : Main control unit : 230(W) x 280(D) x 255(H) mm; Approx. 2.0 kg Titration unit : 120(W) x 363(D) x 610(H) mm; Approx. 4.0 kg Stirrer : 118(W) x 225(D) x 320(H) mm; Approx . 2.0 kg Printer : 106(W) x 180(D) x 88(H) mm; Approx. 0.4 kg

AUTOMATIC POTENTIOMETRIC TITRATOR MODEL: AT-700


Specification : Detection range : 1) Potential: -2000 to 2000 mV 2) pH: -20.00 to 20.00 pH 3) Temperature: 0 to 100 C Titration mode : Auto titration, Auto intermit, Intermit, Stat Number of methods : up to 20 Titration : Potentiometric (acid-base titration / redox titration / precipitation titration) /Photometric / Polarization / Conductometric Titration form : EP stop method, Level stop method, Full Special application : Measurement of electrode potential (pH, potential), acid dissociation constant (pKa) Display : White LED-backlit LCD On-screen display : 1) Potential, titration volume / Measurement result / titration conditions /Parameters 2) Japanese / English / Mandarin Chinese / Korean Calculation : Concentration / Statistics (mean, SD, RSD) / Auto input of blank and factor Data memory : 50 samples Burrete Capacity : 20 ml glass burette (standard) optional 10 ml and 5 ml burette units available

General Equipment

KARL FISCHER MOISTURE TITRATOR Model : Specification MKA-610 : ST Measurement method


Measuring Measurement method
Measuring range

Volumetric titration method 1. Titration Volumetric titration method


2

range

volume : 0.005 to 99.995 mL 2.to 99.995 mL Water content : 0.1mg to 500 mg H2O 1. Titration volume : 0.005 Water concentration 10ppm to 100% H O 3. 2 2. Water content : 0.1mg to 500 mg H O
3. Water concentration 10ppm to 100% H2O Single burette

Burette
Burette

Single burette

Endpoint detection Endpoint sense method

Endpoint detection Endpoint sense method Titration form Burette precision

Polarized potential levelelectrode twin platinum electrode detection with

Polarized potential level detection with twin platinum EP is determined when preset polarized potential

EP is determined when preset polarized potential elapses waiting time elapses waiting time Waiting time range : 1 ~Waiting time range : 1 ~ 99 sec 99 sec Normal titration 1. Capacity : 10 mL burette 2. Dispense precision : 0.015 mL 1. Capacity : 10 mL burette 3. Repeatability : 0.0052. Dispense precision : 0.015 mL

Titration form Burette precision

Normal titration

3. Repeatability : 0.005 mL

mL

Key entry Display

Direct input with keys on the touch screen Cable between the panel and titration unit can be extended

Key entry Display

Direct input with keys on 1. 8-inch (163.2 x 122.4 mm) 256-color Liquid Crystal Display the touch screen with 800 x 600 dots Cable between the panel and titration unit can be 2. Language : English or extended Japanese 1. 8-inch (163.2 x 122.4 mm) 256-color Liquid Crys 3. Real-time display of titration and evaporation curve
Water concentration , Statistics (Mean, SD and RSD), 2. Language : English or Japanese Auto averaging, Blank level and Factor value 3. Real-time display of titration and evaporation

Calculation Other features

Display with 800 x 600 dots

cur

Calculation Other features

1. Stirrer with auto reagent dispenser as standard equpment Water concentration , Statistics (Mean, SD and 2. Auto drift cancellation with potential stat to maintain EP level RSD), 3. Auto titration start byAuto averaging, Blank level and Factor value sensing sample discharge into the flask 1. Stirrer with auto reagent dispenser as standard 4. Up to 10 storage of blank values and factor values.

GLP conformance

External I/O Power source

GLP conformance

Power consumption Dimensions

External I/O Power source Power consumption

equpment 2. Auto drift cancellation with potential stat to maintain EP and record of check results. Check with standards : Notice of check datelevel 3. Auto titration start by sensing sample discharge Reagent factor calibration : Prior notice of date for calibration and reagent, into the change and record of calibration results flask Operator registration : Up to 50 operators can be registered 4. Up to 10 storage of blank values and factor value Check with standards PC (Data capture COM port (Mini-DIN) x 2 channels for printer, balance and: Notice of check date and record of check results. software) Reagent factor calibration : Prior notice of date for calibration 100~120 VAC / 200~240VAC, 50/60 Hz and reagent, change and record of calibration results 1. Touch-screen control Operator registration : Up to 50 operators can be unit : 20W 2. Measuring unit and stirrer : 30W registered 1. Touch-screen control COM port (Mini-DIN) x 2 channels for printer, balan unit : 230W x 280D x 255H (mm) and PC (Data 2. Measuring unit : 120W x 363D x 610H (mm)capture software)
3. Stirrer : 118W x 225D x 320H (mm) 4. Solvent change unit : 100~120 xVAC(mm) 240W x 170D 280H / 200~240VAC, 5. Power burette : 120W x 363D x 610H (mm)

50/60 Hz

1. Touch-screen control unit : 20W 2. Measuring unit and stirrer : 30W

Standard components and parts

Dimensions

Volumetric Karl Fischer measuring unit Solvent unit change 1. Touch-screen control unit : 230W x 280D x 255H (mm) Touch screen main control unit 2. Measuring unit : 120W x 363D x 610H (mm) Magnetic stirrer S-type titration vessel 3. Stirrer : 118W x 225D x 320H (mm) 4. Solvent change unit : 240W x 170D x 280H (mm Twin platinum electrode M714 5. Power burette : 120W x 363D x 610H (mm) Operation manual Others

Standard components and parts

Volumetric Karl Fischer measuring unit Solvent unit change Touch screen main control unit Magnetic stirrer S-type titration vessel Twin platinum electrode M714 Operation manual Others

General Equipment

REFRACTOMETER MODEL: RA-600


Specification : Measuring items : Refractive Index, Brix, Other Concentration Measuring range : Refractive index (nD) : 1.32000 ~ 1.7000 Brix : 0.00 ~ 100.00% Accuracy : Refractive index (nD) : 0.0001 Brix : 0.01% (0 ~ 85.0%) Repeatability : Refractive index (nD) : 0.0001 Brix : 0.1% Resolution : Refractive index (nD) : 0.0001 Brix : 0.1% Temp. compensation : 5.00 ~ 75.00:C Temperature control : Peltier Thermostat 5:C ~ 75:C Display : 4.7-inch TFT Touchscreen Dimensions : 192 (W) x 281 (D) x 166 (H) mm

DENSITYMETER Model : DA-640

SPECIFICATION: Measuring method : Resonant frequency oscillation Measuring range : 0~3 g/cm3, Measuring temp. 0~90C Accuracy : Denstity 0.0001g/cm3 Temperature : 0.05C Repeatability SD 0.00005 g/cm3, Minimum sample required : 1) Approx 1 ml by manual syringe 2) Approx 2 ml by built-in sampling pump Measuring time; 1) 1~4 minutes by manual 2) 2~10 minutes by programmed Display ; 1) 5.7-inch colour TFT LCD; 640 x 480 2) Shows density, specific gravity, oscillation frequency, temperature, Concentration and other messages. Stored up to 100 methods file for measuring conditions on each sample Interfaces: 1) LAN : x1; Personal Computer (PC) 2) USB 1.1 : x2; USB flash drive, keyboard, barcode reader 3) RS-232C : x2; Dot Matrix Printer, Auto Clean and Sampling Unit Multiple sample
changer

General Equipment

ANALYTICAL BALANCE Readout 0.1 mg Internal Calibration


Weighing range (Max) g 120 220 320 Verific. Value mg 1 1 1 Min. Load mg 10 10 10 Reproducibility mg 0.1 0.1 0.1

Model KERN ABJ 120-4M ABJ 220-4M ABT 320-4M

Linearity mg +/- 0.2 +/- 0.2 +/- 0.2

PRECISION BALANCE External Calibration


Model KERN 440-33N 440-35N 440-45N 440-47N Weighing range (Max) g 200 400 1000 2000 Readout g 0.01 0.01 0.1 0.1 Linearity g +/- 0.02 +/- 0.03 +/- 0.2 +/- 0.2

MOISTURE BALANCE - MLS50-3HA160


Specification: Weighing range : 50 g Readout : 0.001 g or 0.01% Moisture : 0-100% Dry mass : 100-0% ATRO : 0-999% LCD graphic display 99 memory possibilities Dimension : 210W x 335D x 156H mm

POCKET BALANCE - CM 150-1N


Specification: Weighing range : 150 g Readout : 0.1 g Weighing plate : 80 x 70 mm Dimension : 85W x 130D x 25H mm Hard case cover Batteries included: Size AA (2x1.5V)

General Equipment

POLARIMETERPS 8000
Specification: Measurement mode: Optical rotation; Int. sugar scale Measurement range: +/- 90; 259Z, 099.9 g/ml Resolution: 0.001; 0.01Z, 0.1g/ml; Accuracy: +/- 0.003; 0.01Z, 0.5g/100 ml Reproducibility 0.002:, Light source LED with filter 589 nm Sample dilutions range: 23, 13 and 6.5 g/100cm Meas. Time +/-90: 1 sec, Wave length: 589nm Temp. Measurement: 0...99.9C; Temp. Accuracy: +/- 0.2C Calibration: Automatic (menu-driven) Display: LCD 5,7 320x240 Pixel Operating: Touch-Display Data storage 100 Measurements Interface: RS 232; Working voltage: 100-250V; 50/60 Hz

Hand Held PolarimeterHP100


Specification : fast application and easy-to-use operating control universal and mobile measurements no need for sample cells integrated temperature measurement and temperature compensation infrared interface for data transfer 99 memory data storage

Melting Point MeterKSPII


Fully automatic measuring instrument Digital temperature control via LCD-display in 0.1C steps Automatic quick cooling by integrated fan RS 232 interface for printer Alarm function when reaching the melting point Sealed keyboard for easy cleaning Error status in plain language (German or English) Short instruction on the instrument
Incl. instrument protective cover and 100 melting point tubes Specification : Measuring range: 25 400C Accuracy : 0.3 C (25 - 200C) 0.5 C (200 - 400 C) Reproducibility : 0.2 C Safety class : IP 20 Dimensions : W 230 x D 210 x H 110 mm

Heating-rate :

to 300 C approx. 4 min to 400 C approx. 7.5 min Weight : approx. 1.8 kg capillary- : 1.4 mm Capillary intake : 1 Power supply : 85 - 264 V, 47 - 440 Hz

General Equipment

GLASSWARE WASHER-DRYER
Prinsip kerja: Mekanik (Vacuum pump)+Thermal (air panas,temperature) + Chemicals (detergent ) dan neutralizer.

Models available: Under counter washers, Standing washers and more

Some models:

Washer Wash Model Levels

Internal Dimensions

Features

Drying (type)

820 LX

Fitur tambahan: user bisa setting 2 program tambahan, eksternal Super Drying; washer508 x 535 x 510 mm chamber drying (heating element) dryer with injection dan internal glassware drying drying (injector+hepa filter) Fully automatic washer/ dryer has an electronic programmable Super Drying; washermicroprocessor capable of storing up dryer with injection 634 x 525 x 500 mm to 42 programs (4 pre-programmed, drying 38 user definable, password protected) for pre-wash, wash, rinse, purified/ DI rinse, HEPA filtered drying & cooling. 1-6 level wash, rack actuated via Drying system : HEPA automatic manifold connection , two filtered chamber and 770 x 1064 x 510 mm stainless still filter protect recirculation and drain pump from direct injection drying debris

1300 LX

1800 LX

1-6

Accessories: Basic basket (PST)

Basic Basket with Spray Arm

Other racks and accessories

General Equipment

CLIMATE TEST CHAMBER CTC 256 Climatic testing of composite materials, concrete, plastics or electronic
components in material technology, the automotive and aerospace industries, and electronics. Interior dimensions: w x h x d: 640 x 670 x 597 mm, volume: 256 l External dimensions: w x h x d: 898 x 1730 x 1100 mm Digital display (LED) of all set parameters, such as temperature, weekdays, time, humidity, fan speed and set-up values - language to be chosen in setup Temperature range with humidity control: from +10 C up to +95 C Temperature range without humidity control: from -42 C up to +190 C Temperature uniformity in chamber: +/- 0.5 up to 2 K Active control for humidifying and dehumidifying (10-98% rh) with digital display of relative humidity - resolution of display: 0,5%, setting accuracy: 1% Halogen interior lighting 2 x 25 W, switchable Voltage: 400 V, 3 phases N, 50 Hz

COOLED INCUBATOR ICP


5 model sizes (53l to 749l) Temperature range 0 to 60 (for ICP 400/500) and (12) to 60 (for Double doors standard for all models: Prevention of contamination

ICP 600/700/800)

and drops in temperature, and at the same time an optimum view of the sensitive load through wide-area interior glass doors Day/night simulation (24-hour cycle) programmable in conjunction with interior lighting (optional) Very good air circulation in the working chamber through sophisticated ventilation technology Intelligent defrosting function

STORAGE CHAMBER IPS 749


The IPS temperature control storage chamber exactly meets the requirements of the food or cosmetics industry, medicine, pharmaceutics for storing samples at constant temperatures: absolute reliability, precision and durability, and particularly environmentally friendly at the same time. Temperature range 14 to 45 Generous chamber volume of 749 litres State-of-the-art control technology based on the P performance class Double doors as standard: Prevention of contamination and drops in temperature, and at the same time an optimal view of the load through fully glazed interior doors Forced air circulation ensures rapid energy transport and optimal temperature distribution

General Equipment

WATERBATH
Waterbath Basic (WNB) Volume (lt) : 7/10/14/22/29/45 Temperature (C) : +10 to +95 plus boiling stage 2-level security through relay cut-out close to set point (ca. +10C) and mechanical temperature limiter TB at 135C Optional water flow cooling for WNB 10-45 (at extra charge) Waterbath Excellent (WNE) Volume (lt) : 7/10/14/22/29/45 Temperature (C) : +10 to +95 plus boiling stage Relay cut-out close to set point (ca. +10C) and mechanical temperature limiter TB at 135C Additionally as standard : either electronic adjustable temperature monitor TWW or alternatively adjustable temperature limiter WB (to be chosen in set up) Optional water flow cooling for WNE 10-45 (at extra charge)

SHAKING WATERBATH

Shaking Waterbath Volume (lt) : 14/22/29/45 Consist of : Waterbath (WNB/WNE) Shaking Device (M00/M01) Special Cover (L4) Perforated Mounting Shelf (M10)

The maximum number of Test tube racks of equal width in your water Bath is calculated as follows : W10/14/22 divide the useful width of the bath by width of the test tube racks W29/45 divide the useful length of the bath by width of the test tube racks.

General Equipment

CLIMATE CHAMBER for stability test in accordance with GMP and ICH
Its excellent temperature and humidity homogeneity positions the climate chamber ICH in the international top league of stability test chambers. Thermal transfer to the interior whether heat or cold is guaranteed through a large-area air jacket on four sides. Thanks to its hermetically sealed interior, the climate chamber ICH does not consume any water once the setpoints have been reached, provided that the door is not opened. Two high-grade platinum temperature sensors with mutual monitoring guarantee interruption-free long-term operation even if one sensor should fail.

3 models: Climate chamber ICH 256 temperature/humidity,


ICH 256L with light, ICH 256C with CO2 control Temperature range from - 10 C to + 60 C (ICH 256), 0 C to + 60 C (ICH 256L and ICH 256C) Chamber volume of 256 litres State-of-the-art control technology based on the Perfect performance class Digitally controlled active humidification and dehumidification from 10 to 80 % rh Double doors as standard: Prevention of contamination and drops or rises in temperature with an optimal view of the chamber load through wide-area interior glass doors.

PELTIER COOLING UNIT CDP 115


Technical data :
Casing Dimensions Electrical connection Power Consumption Effective cooling capacity Pumping capacity of circulation pump for coolant Order Number

: (HxWxD) 185x450x120mm : voltage 230 V, 50/60 Hz : max. 160W : 115 Watt : 600 ml/minute : L8

General Equipment

Specifications MS ES : - Case construction : Steel, with chemically resistant coating - Thermal insulation : Molded silica powder - Heating element : Nichrome wire - Mantle : Woven glass fiber Mat - Element temp. : max of 400C - Speed range : 100 ~ 1000 rpm - Power supply : 220V AC

Specifications MS DM : - Digital temperature controller - Case construction : Steel, with chemically resistant coating - Thermal insulation : Molded silica powder - Heating element : Nichrome wire - Sensor probe : CA (K) Type, 4.8mm dia x 200mm long : 1.5mm lead - Power supply : 220V AC - Temp. range options : Low to 100C max, Medium to 200C

Serial Heating Mantle


Specifications MS EAM : - Body : Steel, with chemically resistant coating - Cover : high grade stainless steel - Thermal insulation : Silica powder mould - Heating element : Nichrome wire - Mantle : Woven fiber glass Mat - Element temp. up to 450C - Choice of 3 or 6 place units

General Equipment

Portable pH Meter Handylab pH 11/14 pH


Measuring range : Range... -2.000..+19.999 pH pH: Resolution max 0.001 pH Accuracy.. +0.005/0.01 pH Range max-1999..+1999 mV Resolution max.0.1 mV Accuracy...+0.3/ 1 mV
Handylab pH11, case set, complete, ready to use with pH combination electrode BlueLine 14pH, calibration solutions and plastic beakers

mV:

Temperature range:.-10+55C 3 point calibration using Buffers Power supply: Battery operated (type AA)

Portable Conductivity Meters Handylab LF11/513T


Measuring ranges Conductivity Range : 0.0uS/cm500 mS/cm 0.00uS/cm19.99 uS/cm 0.000uS/cm1.999 uS/cm Accuracy : 0.5% of measured value Salinity Range : 0.0.70.0 Accuracy : 0.2% TDS Range : 0.1999 mg/l Accuracy : 2% Range : -5...+105.0C
Handylab LF11, case set, complete, ready to use with 2-pole conductivity cell LF 513T, calibration solutions and plastic beaker

Temperature

Power supply: Battery operated (type AA)

Portable Oxygen Meter Handylab OX12

Measuring ranges concentration ranges.0.00...19.99 mg/l / 0...90.0 mg/l resolution max.......0.01mg/l accuracy 0.5% of measured value saturation index ranges ..0.0...199.9% / 0...600% resolution max 0.1% accuracy 0.5% of measured value partial pressure ranges 0.0199.9 mbar / 01250 mbar temperature range 0...+50.0C resolution .0.1K accuracy ... 0.1K

General Equipment

Standard Benchtop Meter - pH METER


Specification
mV measurement Range: -999.9 ... +999.9 mV; -1999 ... +1999 mV Accuracy (1digit) in mV pH measurement Range: -2.000 ... +19.999 pH Accuracy (1digit) Temperature measurement

Lab 850 Lab 860


Range: -5.0C to + 120.0 C Unit C / F selectable

Interfaces

RS-232-C interface, bidirectional USB interface (slave) Diagnostic plug

Data storage

800 records

Additional features Supports all GLP needs

Standard Benchtop Meter - CONDUCTIVITY METER LAB 960

Specification:
Conductivity measurement: Range: 0.000 S/cm to 500 mS/cm TDS measurement with factor 0.4 ... 1.0 Salinity measurement according to Natural Sea Water Scale (UNESCO 1966b) Accuracy in % of measured value (1digit): 0.5 Temperature measurement: Range: -5.0C to + 120.0 C Unit C / F selectable Interfaces: RS-232-C interface, bidirectional USB interface (slave) Supports all GLP needs

Lab 960 Set : Lab 960 including cover Z 880, stand S4D Z 865, power supply Z 850, cond. cell LF 413 T

High End Benchtop Meter - PROLAB 3000 BNC SET


PH Range PH Accuracy (for each measuring area) ( 1 digit) mV Range mV Accuracy (for each measuring area) ( 1 digit) ISERange Temperature Range / Accuracy Accuracy ( 1 digit) Display -2.000 +20.000 pH -2.00 +20.00 pH -2.0 +20.0 pH 0.003 pH 0.01 pH -1999.9 +1999.9 mV -1999 +1999 mV 0.2 mV 1 mV 1.0E-40 9.9E39 mg/l -35.0 +150.0 C 0.1 C QVGA colour graphic display 120 x 90 mm with CFL lighting > 10 000 data sets, storage intervals from 1 s 60 min

The first pH-meter with integrated PCOperate it like Windows

Measuring value storage (manual/automatic)

General Equipment

VISIBLE SPECTROPHOTOMETER GENESYS 20


Specifications : Optical System Spectral Bandwidth Wavelength Range Accuracy Readout Photometric Concentration Range : Grating based, 1200 lines/mm : <=8nm : 325 to 1100 nm : 2.0nm : 20-character, 2-line LCD :ReadoutAbsorbance, %Transmittance, : -0.1 to +2.5A 0 to 125%T 0 to 1999C : 0.003A from 0 to 0.3A 1% from 0.3 to 2.5A : <=0.001A at 0A; 0.004A at 2A : 0.003A/hour : <=0.1%T at 340 and 400nm : RS-232-C (serial)Centronics-compatible parallel) : 13L x 12W x 7 in.H (33 x 30 x 19cm) : 10 lb. (4.5kg)

Accuracy Noise (at 500nm) Drift Stray Radiant Energi Communication Ports Dimensions Net Weight

UV VISIBLE SPECTROPHOTOMETER GENESYS 10S UV-VIS SCANNING

SPECIAL PRICE
GENESYS 10S UV-VIS SCANNING INCLUDE 2 PCS QUART Z CUVETTE

Supplied as Standard GENESYS 10S Series spectrophotometer 6-position cell changer Single cell holder 100 240 V automatic power supply AC power cord Spare fuses Protective plastic cover USB memory device USB cable Note: Software is not included with the instrument and must be ordered separately.

Specification: Optical Design: Dual Beam Spectral Bandwidth: 1.8 nm Wavelength Range: 190 1100 nm Scanning Speed: 10 4,200 nm/min Display: Graphical with LCD backlight 9.7 x 7.1 cm (3.8 x 2.8 in) Printer (optional): 40 column Internal (text and graphics) External USB printer (HP PCL 3 or greater) Connectivity: USB Type A port for USB memory device (front panel) USB Type B port for optional computer connectivity (rear panel) USB Type A port for external printer (rear panel)

General Equipment

UV VIS SPECTROPHOTOMETER (DOUBLE BEAM) EVOLUTION 200 SERIES


Key Features and Benefits Double Beam Geometry with 1 nm spectral bandwidth for precision measurements Application Focused Beam Geometry (AFBG) enables the best performance from microcells, solid samples, and fiber optic probes Precision monochromator for fast and accurate scanning Xenon Flash Lamp provides high energy throughput and 3-5 years of uninterrupted service Standard UV-Vis functions and proprietary CUE analyzer mode for routine and specialized applications. Local Control or PC configurations with INSIGHT software provides compete set of data collection and processing tools Wide accessory range with various temperature control options sample changers, sippers and solid sampling devices System calibration, validation and data security tools Complete set of BIO applications and accessories (Evolution 260)

Model
Spectral Bandwidth Optical Design Light Source Detector Wavelength Range Accuracy Scan Speed Photometric Range

Evolution 201
1nm Double Beam with sample and reference cuvet positions; Czerny-Turner Monochromator Xenon flash lamp, 3-year warranty (Typical lifetime: 5 years) Dual Silicon Photodiodes

190 to 1100nm 0.8nm (full range 190 to 1100nm) (546.11nm mercury line) <1 to 6000nm/min.; variable

>3.5A 0.5A: 0.0004A 1A: 0.006A 2A: 0.010A Measured at 440nm using neutral density filters traceable to NIST*/NLPL

Accuracy

General Equipment

CENTRIFUGE Espresso Personal Microcentrifuge


Specifications Max. Capacity Max. Speed Max. RCF Noise Level Display Max. Timer Range Dimensions (L x W xH) Net Weight

12 x 2mL 14,600rpm 14,500xg <56 dBA Digital 15 sec. to 99 min. plus continuous run 5.9 x 9.8 x 7.9 in. (15 x 25 x 20cm) 9.3 lb. (4.2kg)
rotor 12

Package of Espresso Microcentrifuge, complete with place x 2 ml

MicroCL 17/17R & MicroCL 21/21R


Specifications : Capacity Timer Noise Level Max. Speed MicroCL 17/17R MicroCL 21/21R Max. RCF MicroCL 17/17R MicroCL 21/21R Temperature Temperature Range (17R and 21R only) Dimensions MicroCL 17/21 MicroCL 17R/21R Net Weight MicroCL 17 and 21 24.2 lbs. (11kg) 13.75 x 9.63 x 8.88 in. (25.2 x 24.3 x 22.5cm) 17.5 x 11.63 x 12.88 in. (44.5 x 29.5 x 33cm) -9C to +40C, 1C 17,000xg 21,100xg
Package of MicroCL 17, complete with Hematocrit rotor Package of MicroCL 17/17 R, Complete with 24x1.5/2.0 ml rotor Package of MicroCL 21/21 R, Complete with 24x1.5/2.0 ml rotor

24 x 1.5/2.0mL 1 to 99 min. <56dbA 13,300rpm 14,800rpm

MicroCL 17R and 21R 61.7 lbs. (28kg)

General Equipment

CL2

Specifications Capacity Display [LCD] Control Speed Control Max. Speed Max. RCF Timer 300mL (6x 50mL) 4-character LCD Microprocessor 1000 to 5200rpm, 100rpm 5200rpm 3350 x g 5 sec. to 1 min. in 15 sec. increments; 1 to 5 min. in 5 sec. increments, 5 to 30 min. in 1 min. increments; HOLD to 99 min. 59 sec. <65dBA

Package of CL2, complete with Fix Rotor # 580920F ( 12-Place x 15 ml)

Noise

Dimensions (L x W x H) 15.75 x 13.25 x 10.75 in. (40 x 34 x 27.5cm) Height (Cover Open) Net Weight 24 in. (61cm) 24 lb. (11kg)

CL10

Specifications Capacity Display Control Control Speed Set/Step/Display Max. Speed Max. RCF Feature(s) 4 x 135mL Digital Microprocessor 300 to 6500rpm, 10rpm 6500rpm 3684xG High/Low acceleration and braking 1 to 99 min. plus HOLD Direct-drive brushless induction <57dBA 18.1L x 14.6W x 11 in.H (46 x 37 x 28cm) 61.7 lb. (28kg)

Package of CL10, complete with Fix Rotor F-G1 # 11210018 (6-Place x 50 ml) and adaptor # 11210577 (50ml)

Timer Motor Noise Dimensions Net Weight

General Equipment

Specifications Timer Fixed Speed Fixed RCF Noise Dimensions Net Weight

MEDILITE
0 to 30 min. plus HOLD 2700rpm 920xG ~65dBA 14.75L x 11.5W x 9.5 in.H (37.5 x 29.2 x 24.1cm) 16 lb. (7.2kg)
Package of Medilite, complete with 6-Place Rotor x 15 ml

SL 16/16R
Specifications Capacity Control Display Max. Speed Max. RCF Timer Memory Other Features Motor Temp. set range (for SL40R) 3L (4 x 750mL) Microprocessor Digital 15,200rpm 25,314 x g 9 hr. 99 min. plus HOLD 6 programs, direct access

Auto-Lock III rotor locking system, SMARTspin imbalance detection system, Certified ClickSeal biocontainment system, language selection, 9 acceleration/10 braking profiles, motorized lid latch Direct, brushless induction low-profile motor -10C to 40C
Package of SL16/16R, complete with Swing Rotor bucket TX-200 # 75003658 ( 4-Place x 100 ml), round buckets # 75003659, Sealing caps # 75003660 and Adaptor # 75003801 (100 ml)

SL 40/40R
Specifications Capacity Control Display Max. Speed Max. RCF Memory Timer 1.6L (4 x 400mL) Microprocessor Digital 15,200rpm 25,830 x g 6 programs, direct access 9 hr. 99 min. plus HOLD Auto-Lock III rotor locking system, SMARTspin imbalance detection system, Certified ClickSeal biocontainment system, language selection, 9 acceleration/10 braking profiles, motorized lid latch Direct, brushless induction low-profile motor <61dBA

Other Features

Motor Noise

Temperature -10C to 40C Set renge (for SL16R)

General Equipment

BOD Measurement System BOD OxiDirect


Specification : Measuring principle : Manometric, mercury free, electronic pressure sensor Range 0-40, 0-80, 0-200, 0-400, 0-800, 0-2000, 0-4000 mg/l O2 Accuracy : 0.5% full scale at 20C Measurement parameter display : BOD range, volume, duration, time

BOD Incubator ET 618-4


Specification : Temperature range : +2C to 40C, in step 1C Resolution : 0.1C Net Capacity 135 liters LCD display fan output 320m3/h, come with 3 shelves Weight 39 kg Internal dimension : 515L X 430W X 700H mm External dimension : 600L X 600W X 820H mm

MD 200-COD VARIO SET UP

NEW

Technical Data : Optics : LEDs, interference filters (IF) and photo sensor in transparent sample chamber Wavelength specification : 430 nm interference filter 610 nm interference filter Wavelength Accuracy : 1 NM Photometric Accuracy : 3% FS (T=20 C-25 C) Photometric Resolution : 0,01 A Power supply : 4 batteries (AA) Capcity approx. 53 hours or 15000 test (continuous operation with backlit switched off Auto-Off : automatic switch off Storage : internal ring memory for 16 data sets

Portable Turbidity Meter TurbiCheck


Specification : Measurement cycle : approx. 8 seconds Display : LCD-display Optics : temperature-compensated LED and photosensor amplifier in water protected sample chamber, infrared light Sample chamber : Waterproof Measuring range : 0.01 1100 NTU Power supply : 9V power pack battery

General Equipment

WATER PURIFICATION SYSTEM

GENPURE UF/UV
Specification:

Flow rate, up to Operating pressure in bar, min/max Conductivity Resistance at 25 C TOC value Bacterial content in KbE/ml Particles Endotoxines in EU/ml Electrical requirements Power consumption Feedwater connector Dimensions B x T x H in mm Weight

: up to 2 l/min : 2 6 bar : 0.055 S/cm : 18.2 Mxcm : 1 5 ppb : <1 :<1 : 0,001 : 230 V / 50Hz : 1 kW : R 3/4" : 372 x 330 x 615 : 23 kg

LAB TOWER EDI-15


Specification : Ultra-pure water specifications ASTM type I: Conductivity in S cm Resistance in M cm Removal performance l/min. TOC-Value in ppb TOC-Value in ppb (models with UV) Bacteria content in KbE/ml with sterile filter Particle content per ml with sterile filter Optional Retention of Endotoxins*, RNase*, DNase*

: 0.055 : 18.2 : up to 2 : < 10 :15 :<1 :<1 : Ultrafilter

Pure water specifications ASTM type II : Conductivity** in S/cm : 0.067 0.1 Resistance** in M cm : 15 to 10 RO-EDI rate of production into the tank at 15 C, l/h : 15 / 30 Silicate retention in % : > 99.9 Technical specifications Connection voltage in V/Hz : 230 / 50-60 Power consumption in kW : 0.25 Feed water connector : d8/R3/4" Ambient temperature in C : + 2C + 35C Dimensions in mm WDH : 450 580 1.500

General Equipment

ME 2C NT
One-stage diaphragm pumps are an excellent solution for continuous, oil-free pumping of gases and vapors at low vacuum requirement. In contrast to waterjet pumps they do not consume water and therefore do not produce any contaminated waste water in daily use. Typical applications are vacuum ovens, filtrations and multi-port manifolds for medium throughput, as well as pumping of gases and oil-free evacuation in general. The one-stage construction provides the advantageous combination of high pumping speed and low ultimate vacuum down to 70 mbar. Technical Data : Number of heads / stages Max. pumping speed at 50/60 Hz m3/h Max. pumping speed at 50/60 Hz cfm Ultimate vacuum (abs.) mbar/torr Ambient temperature range (operation)C Ambient temperature range (storage)C back pressure (EX) (abs.) bar Inlet connection (IN) 10 mm Outlet connection (EX) 10 mm Rated motor power kW Rated speed at 50/60 Hz min-1 Degree of protection Dimensions (L x W x H) mm Weight kg Noise level at 50 Hz, typ. dBA :1/1 : 2.1 / 2.4 : 1.2 / 1.4 : 70 / 52 : 10 - 40 : -10 - 60Max. : 1.1 : Hose nozzle DN : Hose nozzle DN : 0.18 : 1500/1800 : IP 40 : 243 x 211 x 198 : 10.2 : 45

Vacuum controller CVC 3000E C3


Performance features: -controls vacuum, cooling water and venting on demand -intuitive operation with turn-and-tap jog wheel and clear text menus in 14 languages -interactive communication (PC) through RS 232C serial interface -manual/semi-automatic determination of vacuum setting -automatic setting of hysteresis with manual override Item Consist of: -CVC 3000 work station controller with mounted -in-line solenoid vacuum valve C3 and mounting rod. -With hose nozzles DN 6/10 mm towards pump and application. Ordering data : Product name Mains voltage and frequency Plug CVC 3000E C3 100-230 V~ 50-60 Hz CEE/CH/UK/US/AUS Order no. 2614120

General Equipment

ROTARY VACUUM PUMP RE 2.5 / RZ 2.5


The one-stage RE 2.5 and two-stage RZ 2.5 are high-performance rotary vane pumps with extra compact design and low weight. They are the ideal solution for a wide range of laboratory and process applications that require low ultimate vacuum at medium gas flow rate. The pumping unit is compact, user-friendly, and well-arranged, with oil mist filter at the outlet, a valve, and a T-connection for a gauge. The RZ 2.5 is also available combined with the oil mist filter (FO) and the VS 16 valve as a package.

Technical data Number of stages Max. pumping speed at 50/60 Hz Max. pumping speed at 50/60 Hz Ultimate partial vacuum (abs.) Ultimate vacuum (abs.) Ultim. vac. (abs.) with gas ballast Water vapor tolerance Ambient temperature range (operation) Ambient temperature range (storage) Oil capacity (B-Oil) min / max Max. back pressure (EX) (abs.) Inlet connection (IN) Outlet connection (EX) Rated motor power Rated speed at 50/60 Hz Degree of protection Dimensions (L x W x H) mm kW

Unit 1 m3/h cfm mbar mbar/torr mbar/torr mbar C C l bar 2.3 / 2.8 1.4 / 1.6 3 x 10
-1 -1 -1

RE 2.5 2 2.3 / 2.8 1.4 / 1.6 4 x 10


-1 -4 -3 -2

RZ 2.5

3 x 10 / 2.3 x 10 8 x 10 / 6 x 10 40 12 - 40 -10 - 60 0.18 / 0.51 1.1


-1

2 x 10 / 1.5 x 10

-3 -2

1 x 10 / 0.75 x 10 40 12 - 40 -10 - 60 0.1 / 0.28 1.1

Small flange KF DN 16 Hose nozzle DN 10 mm 0.18 1500/1800 IP 40 316 x 125 x 190

Small flange KF DN 16 Hose nozzle DN 10 mm 0.18 1500/1800 IP 40 316 x 125 x 190

min-1

RE 2.5

RZ 2.5

General Equipment

VARIO chemistry diaphragm pump MZ 1C VARIO

Technical data Vacuum controller Number of heads / stages Max. pumping speed (m3/h) Max. pumping speed (cfm) Ultimate vacuum (abs.) mbar/torr Ultim. vac. (abs.) with gas ballast mbar/torr Ambient temperature range (operation) C Ambient temperature range (storage) C Max. back pressure (EX) (abs.) bar Inlet connection (IN) Outlet connection (EX) Rated motor power kW Motor speed range min-1 Degree of protection Dimensions (L x W x H) mm Weight kg CE mark Items supplied Accessories : CVC 3000 :2/2 : 1.0 : 0.6 : 12 / 9 : 20 / 15 : 10 - 40 : -10 - 60 : 1.1 : Hose nozzle DN 10 mm : Hose nozzle DN 10 mm : 0.16 : 200 - 2200 : IP 20 : 263 x 156 x 299 : 4.9 : Yes : Pump completely mounted, ready for use, with manual. : Rubber vacuum tubing DN 10 mm (686002)

Ordering data Product name MZ 1C VARIO

Mains voltage and frequency 200-230 V~ 50-60 Hz 100-120 V~ 50-60 Hz

Plug Order no. CEE 696670

General Equipment

Chemistry DIAPHRAGM PUMP MZ 2C NT


Chemistry-design diaphragm pumps are an excellent solution for continuous, oil-free pumping of corrosive gases and vapors. The two-stage construction provides the advantageous combination of high pumping speed and low ultimate vacuum. All major parts in contact with pumped media are made of chemically resistant fluoroplastics. The new NT-series features further improved performance data and superior vapor tolerance. Technical data Number of heads / stages Max. pumping speed at 50/60 Hz Max. pumping speed at 50/60 Hz Ultimate vacuum (abs.) Ultim. vac. (abs.) with gas ballast Ambient temperature range (storage) Max. back pressure (EX) (abs.) Inlet connection (IN) Outlet connection (EX) Rated motor power Rated speed at 50/60 Hz Degree of protection Dimensions (L x W x H) Weight CE mark NRTL certification Items supplied Accessories mm kg kW min-1 m3/h cfm mbar/torr mbar/torr C bar :2/2 : 2.0 / 2.3 : 1.2 / 1.4 :7/5 : 12 / 9 : 10 - 40 : -10 - 60 : 1.1 : Hose nozzle DN 10 mm : Hose nozzle DN 10 mm : 0.18 : 1500/1800 : IP 40 : 243 x 243 x 198 : 11.1 : Yes :Canada and the USA :Pump completely mounted, ready for use, with manual : Rubber vacuum tubing DN 10 mm (686002)

Ambient temperature range (operation) C

MZ 2C NT +AK+EK

This chemistry vacuum system has a wide range of applications like evacuation, evaporation and pumping of gases and vapors in chemical, biological and pharmaceutical laboratories. Typical applications are rotary evaporators, vacuum concentrators and vacuum drying ovens. The separator at the inlet (AK), made of glass with protective coating, retains particles and liquid droplets. The waste vapor condenser at the outlet (EK) is highly efficient and compact. The condenser enables near-100-percent solvent recovery, efficient recycling, and active protection of the environment.

General Equipment

LABORATORY BLENDER
Capacity : 1 liter Switch setting : two speed : high 22,000 and low 18,000 60 second mechanical timer Base : die cast epoxy coated base (8010BU) Container : stainless steel container with handle and stainless steel
cover (SS610) Overall height : 15 inches (38 cm) Weight : 9.4 lbs (4.3 kg) Rated volts : 230 volts, 50/60 Hz

Base Unit : 8010BU Container : SS610

Capacity : 4 liter Switch setting : Off Lo Med Hi Pulse RPM : 16,800 18,800 21,500 21,500 Rating : 230 Volts 50/60Hz Single phase AC -7.5Amps Base : Die cast gray epoxy coating Container : Stainless steel with Stainless steel blades Stainless steel
clamp on lid with rubber gasket & stopper Bearing : High performance ball bearings Overall height : 22.25 inches (56.5 cm) Weight : Net shipping weight 38 lbs (17.24 kg)

24 CB10C

Specification:

Technology : Microprocessor With stainless foot pedal, with 2 programs: Standard and Start-Stop with timer, 60 min. SCS (Safety Control System) with BHC (Burner Head Control) Gas types: II2ELL3B/P: natural gas E/LL,18-25 mbar liquid gas, 20-50 mbar Removable and decomposable burner head Holding device for 3 inoculation loop holders Nozzles for natural gas, propane/ butane gas Flame temperature: 1350 oC on liquid gas
1300 oC on natural gas (E) Screwdriver for burner head and cover of burner shaft Power connection: 100-240 V/ 50/60 Hz/ max. 0.3 A 9 V DC/ 1 A

FUEGO SCS BASIC

Anda mungkin juga menyukai