Anda di halaman 1dari 2

N30P DIGITAL PANEL METER

NE

FEATURES:

Measurement of single-phase network parameters: voltage, current, ac ve, reac ve and apparent power, cos , tg , , frequency, ac ve, reac ve and apparent energy, 15 minutes ac ve power, 10 minutes voltage, 10 seconds frequency. Three-colour display (14 mm high), in three intervals of the measured value. Meter programming from the keyboard or through the RS-485 interface by means of the free delivered LPCong program. Four alarm outputs with signalling by LED diodes, opera ng in 6 dierent modes. Storage of minimal and maximal values for all measured quan es. Conversion of any measured value into a 0/4...20 mA or 0...10 V analog signal. Storage of minimal and maximal values for all measured quan es.

EXAMPLE OF APPLICATION INPUTS:


KD7 recorder RS485 Modbus

Alarms

N30P digital meter


Converter RS485/USB (e.g. PD10) a.c. motor

PC Computer/ configuration by LPConfig program Current

Voltage

OUTPUTS:

Measurement and recording of energy consump on in 1-phase or three-phase symmetrically loaded network

INPUTS
Input kind Voltage input Current input Input kind Measuring range 0...100 V or 0...400 V 0...1 A or 0...5 A Rated opera ng condi ons 0.05...1.2 Un 0.005...1.2 In Measuring range 0.02...6 A a.c. 1...480 V a.c. 45.00...66.00...100.00 Hz -2.88 kW...1.40 W...2.88 kW -2.88 kvar...1.40 var...2.88 kvar 1.40 VA...2.88 kVA -1...0...1 -1.2...0...1.2 0...359 0...9 999 999.9 kWh 0...9 999 999.9 kVarh 0...9 999 999.9 kVA 0.00..23.59 Basic error 0.2% 0.2% 0.2% 0.5% 0.5% 0.5% 0.5% 1% 1% 0.5% 0.5% 0.5% 1 sec/ 24 h Ra o values 0.1...4000.0 1...10000

MEASURING RANGES
Indica on range 0.000...60 kA 0.0...192 MV 45.00...100.00 Hz -19999...99999 MW -19999...99999 Mvar 0.00...99999 MVA -1...1 -1.2...1.2 0...359 0...9 999 999.9 kWh 0...9 999 999.9 kVarh 0...9 999 999.9 kVA 0.00...23.59

GALVANIC ISOLATION:

Export department: English: +48 68 32 95 302 / 321 / 276 / 386 / 233 German: +48 68 32 95 305 French: +48 68 32 95 304 Russian: +48 68 32 95 321 Fax: +48 68 32 54 091 e-mail: export@lumel.com.pl LUMEL S.A. ul. Sulechowska 1 65-022 Zielona Gra POLAND

Current 1 A/5 A Voltage 100 V/400 V Frequency Ac ve power Reac ve power Apparent power Cos Tangens Ac ve energy Reac ve energy Apparent energy Current me Output kind Relay output Analog output Energy pulse output

OUTPUTS
Proper es 2 x relays, voltageless NO contacts, load-carrying capacity 250 V a.c./ 0.5 A a.c. 2 x relays, voltageless change-over contacts, load-carrying capacity 250 V a.c./ 0.5 A a.c. current programmable 0/4...20 mA, load resistance 500 voltage programmable 0...10 V, load resistance 500 resolu on 0.01% of the range OC type output, passive of class A, acc. to EN 62053-31, supply voltage 18...27 V, current 10...27 mA. Output pulse constant: 5000 imp./kWh, independently of Ku and Ki se ngs.

WWW.LUMEL.COM.PL

N30P DIGITAL PANEL METER


DIGITAL INTERFACES
Interface type RS-485 Transmission protocol MODBUS RTU Mode 8N2, 8E1, 8O1, 8N1 Baud rates 4.8; 9.6; 19.2; 38.4 kbit/s

EXTERNAL FEATURES
Readout eld Weight Overall dimensions Protec on grade (acc. to EN 60529) Supply voltage Temperature Rela ve humidity Opera ng posi on External magne c eld Short dura on overload (5 s) 5 digit LED display indica on range -19999..99999 digit height: 14 mm < 0.2 kg 96 48 93 mm from frontal side: IP65 three-colour display (colour changes depending on displayed value): red, green, orange

SEE ALSO:

Panel cut-out: 92+0,6 45+0,6 mm from rear side: IP 10 Power consump on < 6 VA storage: -30...70C condensa on inadmissible

RATED OPERATING CONDITIONS


85...253 V a.c. (40...400 Hz) or d.c., 20...40 V a.c. (40...400 Hz) or d.c. ambient: -25...23...55C 25...95% any 0...400 A/m voltage input: 2Un (max. 1000 V) Noise immunity Noise emissions

Free LPCong so ware for easy programming. Available on our website

current input: 10 In

SAFETY AND COMPATIBILITY REQUIREMENTS


Electromagne c compa bility Safety requirements

acc. to EN 61000-6-2 acc. to EN 61000-6-4 acc. to EN 61010-1 Current transformers with inputs from 5 A up to 6 kA.

CONNECTION DIAGRAMS

Supply

Supply

Fig. 1 Electrical connec ons of the N30P meter for direct measurements. Fig. 2 Electrical connec ons of the N30P meter for indirect measurements.

N14 meter for measurement of three-phase network parameters.

ORDERING
TABLE 1. ORDERING CODES:
N30P - X
Supply: 85...253 V a.c./d.c. 20...40 V a.c./d.c. Addi onal outputs: lack pulse output, RS-485, analog outputs pulse output, RS-485, analog outputs switched-over relay outputs Unit: unit code acc. to the table 2 Version: standard custom-made* Language: Polish English other* Acceptance tests: without extra requirements with an extra quality inspec on cer cate acc. to customers request* N30P 1 0 01 00 E 0 1 2 0 1 2 XX 00 XX P E X 0 1 X

OUR OFFER

TABLE 2. CODES OF HIGHLIGHTED UNIT:


X
Code 00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 Unit lack of unit V A mV kV mA kA W kW MW var kvar Mvar VA kVA MVA kWh MWh kvarh Mvarh Code 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 Unit kVAh MVAh Hz kHz k C F K % %RH pH kg bar m l s h m3 obr Code 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 XX Unit szt. imp rps m/s l/s obr/min rpm mm/min m/min l/min m3/min obr/h m/h km/h m3/h kg/h l/h on order*

X XX XX X

www.lumel.com.pl

For more informa on about LUMEL's products please visit our website: www.lumel.com.pl

Order example: The code N30P - 1 0 01 00 E 0 means:

Export department: English: +48 68 32 95 302 / 321 / 276 / 386 / 233 German: +48 68 32 95 305 French: +48 68 32 95 304 Russian: +48 68 32 95 321 Fax: +48 68 32 54 091 e-mail: export@lumel.com.pl LUMEL S.A. ul. Sulechowska 1 65-022 Zielona Gra POLAND

- programmable N30P panel digital meter - supply: 85...253 V AC/DC - lack of addi onal outputs - unit "V" acc. to codes tabel 2 - standard execu on - English language - without extra requirements

* - a er agreeing with the manufacturer

WWW.LUMEL.COM.PL

N30P-19

Anda mungkin juga menyukai