System Wiring Diagram

The main Components of Our MV-VFD Components IGBT IGBT Driver Optical Fibre/ connector PLC Contactor Rectification bridges Electrolytic capacitor Transformer Cooling Fan CPLD/FPGA DSP AD chip Air Circuit Breaker Brand Infineon CONCEPT Country Germany Swiss America Germany France Germany Germany China Germany America America America Swiss

Agilent
Siemens Schneider SEMIKRON EPCOS Newonder ROSENBERG ALTERA TI ADI ABB

MV-VFD Multi Motor Concepts

Our Scope of Supply: ------------------------------------------------------ Plant Study to estimate the Potential energy saving applications Supply of complete set of a Multi-Level Power Cell Cascaded Technology based VFD +Integrated Dry Type, 3 Phase Shifting Transformer with H class Insulation + By-Pass Control System (Automation and Manual) Free Spare Parts Commissioning Free Service for 1st 2 years Service Guarantees Product Guarantee MV-VFD Product Training Flexible Payment Terms Handles the repair, migration and

modification of its products and systems. Parts, Field services, Remote customer support Offers a comprehensive portfolio of customizable education and training programs covering Product, Operation and Maintenance, Technology. These programs can be delivered @On site.

Parameter
Drives Rating Motor Input Voltage Motor Power Inverter Type Cooling of Drives Total Losses in Drives No. of Pulses No. of Level THD at Output Drives Switching Frequency No of Power Cell will be Used Voltage of each Power Cell Power Cell By- Pass facility Voltage DE rating if 1 power cell fails Technology Speed Control Technology Transformer Type Output Transformer Transformer Winding By- Pass Cabinet Static Speed Error accuracy Torque Ripple Input Frequency Input Power Factor System Efficiency Output Frequency Power Semiconductor IGBT current Output Choke Output Frequency Resolution MTBF Analogue Output

Value
250 KVA-8500 KVA 3.3 /4.16/6.6/6.9/11 KV 125 KW- 8 MW Multi-Level cascaded H-Bridge Air Cooled Drive 2-3% 24/36/48/54/60 5/9/11 < 3 % (Voltage),< 2% (current)
1.2 KHz

Fuse withstand capability Control cable Noise Communication Cable by-passing Enclosure Overload Facility Starting Torque Output Waveform Logical control I/O signals Output Sine Filter Cooling Methods Operating Environmental Temp Ambient Humidity Ambient Temperature Storage Temperature Altitude Boolean

2 KV Optical Fiber < 70 DB CAN/Profibus/ Modbus/ RS 232/RS 485 etc cables are passing by inside or outside as suitable for the customer IP 40 120 % (1 min), 150% (3 s), 200% (immediate) 150% Sinusoidal 16 channels respectively Not Required Forced Air Cooling 0-45 degree C 95%, no condensation -35 to +45 0-45 < 1000 m Input / Output Communications/ Default Point (expandable)

12/18/21/24/27/30 690 V Available to every Power cell Approximately 2-5% PWM V/F, Sensor less Vector Control Inbuilt Dry Type, air cooled, 3 phase shifting, H Class Insulation Not Required Y/ Inbuilt, will have manual as well as automatic operation 0.01 Hz No Torque Ripple 45-65 Hz 0.96 (> 20% of Rated Load) 96% (Under a rated Load) 0.5 to 120 Hz LV- IGBT 31 A to 1000 A Not required for 1 KM distance between drive and motor 0.01 Hz More than 7 years 0-10 V/ 4-20 mA optional (2Channel)

Applications Field: Power Generation: Induced draft fan, forced draft fan, condensate pump, feed pump, primary air fan, secondary air fan, booster fan, circulating pump, mill fan, slurry pump Cement: draft fan, high-temperature fan, air blower, dust collection fan, grinding machine etc. Metallurgy: blast furnace blower, slurry pump, feed water pump, dust fan, compressor etc. Petroleum & Chemical: Water injection pump, crude oil pump, Compressor, fan, circulation pump, etc Oil & Gas: water injection pump, oil transfer pumps, air compressor. Urban water supply: Water delivery pump, water intake pump, water supply pump, sewage treatment industry, self-fractionating pump etc Minerals & Mining: Mud pump, ventilation fan, Belt conveyor, slurry pump etc

By-pass Cabinet:

Shares most of the common mode voltage, motor is free of influence of common mode voltage Transformers secondary winding is divided into three groups; normally, 24pulse, 36-pulse, 48-pulse, 60-pulse series The independence of transformers secondary winding makes easy to utilize mature technology

Power Cell Cabinet

By-pass Cabinet With both Automatic And manual Operation It may employ isolating braker, vaccum contactor of both Has function of all five protections. It has pressure relief channel so it can rival the Medium voltage switchgear

No external PF correction capacitors required High efficiency over the whole speed range

Transformer Cabinet:

Power Cell Bypass Facility


Output of neighboring power cells are connected in series in Y form, which can realize high voltage output. Each power cell undertakes 1/n phase voltage, 100% motor current, 1/3n output efficiency. Up to 3 power cell failure is allowed and no process interruption due to tripping. This gives inbuilt redundancy in power side. Multi-level cascaded technology consists of total N no of power cell ( N/3 no of power cell in series in each phase) develop medium voltage. No output transformer requires. No common mode voltage stress, No additional bearing current, No additional heating of Motor windings. Very low dv/dt Due to multi-level cascaded technology allows MV drive to motor distance up to 1000 meter

Multi-Grade Design Provides galvanic isolation H-class insulation, 150 degree Withstand capability Dry type air cooled indoor installation

Power Cell Control Cabinet:

Each power cell is AC-DC-AC voltage source Power factor of single power cell is 0.97, overall system is .96. Power Factor doesnt change throughout the entire speed range Communication between power cells and control system is performed by Fiber optic that can handle the problem of separation between heavy current and light current as well as electric & magnetic Interference The power cell and control system have a very good protective design to dust, ferrum pulveratum, acid mist, moisture etc

Control Cabinet is used for installation of low voltage control components: PLC, UPS, Electric Siren, DC 24 V power supply, Control Power Source Switch, Wiring Terminals, Touch Screen, Operation Button etc. Control System Components: Main Controller Speed amplifier, Current Amplifier, Firing Circuit with Pulse Amplifier, Input / Output port for Analog/ Digital Signal, and digital reference unit with remote control Industrial Control Computer Control Technologies: V/F Control, Sensor less Vector Control

Parts of Controller Cabinet

Emergency Stop Button Local / Remote Control Switch System Reset Button Alarm Cancellation Button

Reliability Power cell By-pass facility Rugged IGBT power circuit , Each Power cell tested at full current MTBF= 7 years Extended under-voltage operation (-30%), Power loss ride-through (5 Cycle), Fiber optic communication On-line monitoring and diagnostics, Modular Draw-out Power Cells Manufacturer: ZhuHai Wanlida Electric Co Ltd, China

Power Quality

Clean Power converter, Near Sine wave at Input and Output of converter 36/54/60 Pulse, Meets all new requirements of IEEE 519 for Harmonics distortion Eliminates the need to do harmonic analysis Eliminates costly harmonic filters required for distortion control

Our Products: Multilevel Cascaded Power cell bypass Technology based Medium Voltage Drives for 125 KW to 8 MW and 3.3 KV to 11 KV Motor. Magnetic Controlled Rectifier Type Static Var Compensator Magnetic controlled Soft starter Active Power Filter Protection Relays Medium Voltage Electric Motor Temperature Sensor Energy Efficient Motors Contact Us:

EAGLE TECHNOLOGY
Address: No. 201, L-2, B-11, Surya City, Bangalore-560081 E-mail: eagleteam.in@hotmail.com, Web: http://eagletechnology.in Contact Person: Mr. Sunil Jha E-mail: jhasunil100@gmail.com Phone: +91-9590-273474

Power Line Immunity Standard lightning arrester on primary of input transformer. Transformer impedance limits surge energy to cells. Diode rectifier close-coupled to large DC capacitor allows cells to absorb surge energy safely. Stored energy in cell capacitors allows ride-through of input voltage dips. If voltage is restored, drive can re-start into spinning load.

Motor Compatibility Near sinusoidal current and voltage@ all speeds and loads No additional motor heating or voltage stress to insulation compared to sine wave operation Safely applied to 1.0 service factor motors No additional bearing current No dv/dt problem Compatible with standard motors New or retrofit applications No output Choke required even for 1KM Distance between drive and Motor