ALU
1
2 | 2G-3G Telecom Procedures:
Motivation: Enable operators to prioritise UTRAN FDD in cell reselection, for dual mode MS. Reduce signalling load due to LAU/RAU.
Currently: When the MS releases all TCHs or SDCCH and returns to idle mode or packet idle mode, it shall, as quickly as possible, camp on the cell whose channel has just been released Result: Increased number of LAU/RAU, in case GSM and UMTS cells belong to different Location Area/ Routing Area.
In B10 (Rel6 compliant feature): The network can order the MS to directly camp on a specific cell (either UMTS or GSM cell). This preference is signalled in the CHANNEL RELEASE message (IE: cell selection indicator after release of all TCHs and SDCCH). The new IE signal the frequency on which the MS shall camp. If this IE is absent, camping failed within 10 sec, or none of the cells are suitable current specs is followed. FDD_ARFCN_LIST is sent in this IE as preference.
Parameter
Description
Range
Object
Conditions/Rules
EN_FAST_3G_Reselection
fast 3G cell
Cell
Example
3G Layer
HO Connected mode
Note
2
6 | 2G-3G Telecom Procedures:
The main objective of this feature is reduction of call setup time for dual mode mobiles. Enhance End user perception. Avoid loading SDCCH.
In Rel5, a mandatory change is introduced for reduction of InterRAT Handover INFO message size. In the Immediate Assignment message, the Compressed_Inter_RAT_HO_INFO_IND indicates to the MS whether a compressed version of the InterRAT Handover Info message shall be used or not.
Parameter
Description
Range
Object
Conditions/Rules
EN_Compressed_InterRAT _HO_Info
Enables the BSS to require the usage by a dual mode mobile of the compressed format of INTER RAT HO INFO IE
BSC
is required from the all RNCs neighbor MS. to this BSS support 0 compressed format of INTER RAT HO INFO IE the feature.
Note
8 | 2G-3G Telecom Procedures: All Rights Reserved Alcatel-Lucent 2006, #####