1997 Chromatography Products Catalog - Restek Corporation


GC CAPILLARY COLUMNS
from the specialists in chromatography

28

Rtx-1301 / MXT-1301
r Rtx-1301 / MXT-1301 Unique polarity ideal for a wide variety of applications. Equivalent to USP G43 stationary phase used for solvent impurity analysis in pharmaceutical products. The Rtx-1301 and MXT-l30l columns use a highly selective, intermediate polarity stationary phase that has become popular in recent years. The Rtx-1301 / MXT-1301 polymer required completely new synthesis routes compared to other Restek polymers. Our silicone synthesis chemists chose polymerization reactions that did not cause carboxyl amide formation of the critical cyano groups. The polymer backbone structure was also modified in a way that achieved stable polymer formulations at high temperatures. The result from this new polymer formulation was low bleed, even with sensitive detectors such as ECDs, NPDs, and MSDs. Restek' s 1301 has been found by many analysts to be the best cyanosilicone bonded stationary phase available, with no other column manufacturer having lower bleed, longer lifetime, or better inertness. The polymer is fully characterized to ensure long-terni reproducibility and column-to-column consistency. Characterization testing includes RI, FTIR, Kovats Indices. % crosslinking, efficiency. and a five-day thermal bake-out to ensure column longevity. New batches of polymers are used only when they meet Restek's stringent QA tests, and each lot is subsequently tracked in an extensive data base for future reference. Rtx-1301 / MXT-1301 columns exhibit excellent inertness for many reactive compound classes, including pesticides and herbicides. However. strongly acidic compounds should be excluded

COSOD R SB N
Restek's Crossbond procedure produces columns with lower bleed and longer lifetime and allows rejuvenation through solvent rinsing.

Rtx-1301
(Fused Silica)

(Crossbond 6% cyanopropylphenyl 94% dimethylpolysiloxane) Stable to 280C. temp. limits -20 to 2800C -20 to 2800C -20 to 2700C -20 to 2600C -20 to 2800C -20 to 2800C -20 to 2700C -20 to 2600C -20 to 2500C -20 to 2800C 0 -20 to 280 C -20 to 2700C -20 to 2600C 0 -20 to 250 C 0 -20 to 240 C 15-Meter 16005 16020 16035 16050 16006 16021 16036 16051 16066 16007 16022 16037 16052 16067 16082 30-Meter 16008 16023 16038 16053 16009 16024 16039 16054 16069 16010 16025 16040 16055 16070 16085 60-Meter 16011 16026 16041 16056 16012 16027 16042 16057 16072 16013 16028 16043 16058 16073 16088 75-Meter 105-Meter 16014 16029 16044 16059 16015 16030 16045 16060 16075

Applications: volatile organics, pharmaceutical samples, alcohols, oxygenates, pesticides, Arochlors

ID 0.25mm

0.32mm

The maximum temperatures listed are for 15- and 30meter lengths. longer lengths may have a slightly reduced maximum temperature.

0.53mm

df(um) 0.10 0.25 0.50 1.00 0.10 0.25 0.50 1.00 1.50 0.10 0.25 0.50 1.00 1.50 3.00

16076

16091

MXT-1301 Restek's
(Silcosteel)

Crossbond 6% cyanopropylphenyl 94% dimethylpolysiloxane) Stable to 280C.

MXT columns
rugged, flexible fused-silicalined, stainless

ID
0.25mm

df(um) temp. limits 15-Meter


0.25 0.50 1.00 1.50 -20 to 2800C 76021 76036 76051 76(166 76022 76037 76052 -20 to 270~C -20 to 260~C -20 to 2500C -20 to 280~C -20 to 2700C -20 to 2600C -20 to 2500C -20 to 2400C

30-Meter
76024 76039 70054 70069 76025 76040 76055

60-Meter
76027
76042 76057 76072 76028 76043 70058

0.53mm

0.25 0.50 1.00

1.50 3.00

76067 76082

76070 76085

76073 76088

Restek Australian Distributors

Chromalytic Technology Pty Ltd


Fax : +61 3 9761 1169 Phone :
+61 3 9762 2034

E-mail : jimjeffs@chromtech.net.au

Copyright Restek Corp. and Chromtech : 1997 - All rights reserved