Anda di halaman 1dari 7

Honeywell International, Inc. - Predict 6.

Project Data Project Name: Company Name: Stream Name: Field Name: Project Data: Address: Phone Number: Fax: E-mail: User Comments: Add your comments here

Created On: 17.05.2012 15:12:20

Stream132012517142053.pdf

Page 1 of 7

Operating Units:

Metric

Process Data Inlet Temperature: Inlet Pressure: Operating Conditions Outlet Temperature: Outlet Pressure: H2S Partial Pressure: Gas Composition CO2 Partial Pressure: Sodium (Na+): Magnesium (Mg++): Calcium (Ca++): Cations At Inlet Iron (Fe++): Barium (Ba++): Manganese (Mn++): Chloride (Cl-): Formate (HCOO-): Acetate (CH3COO-): Sulfate (SO4--): Anions At Inlet Bicarbonate (HCO3-): Sulfide (S--): Carbonate (CO3--): Hydroxide (OH-): Bisulfide (HS-): Sodium (Na+): Magnesium (Mg++): Cations At Outlet Calcium (Ca++): Iron (Fe++): --------------- Continued --------------0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0,053 bar 0 ppm 0 ppm 0 ppm 14,3 C 6,9 bar 0 bar 14,3 C 6,9 bar

Created On: 17.05.2012 15:12:20

Stream132012517142053.pdf

Page 2 of 7

Process Data Barium (Ba++): Manganese (Mn++): Chloride (Cl-): Formate (HCOO-): Acetate (CH3COO-): Sulfate (SO4--): Anions At Outlet Bicarbonate (HCO3-): Sulfide (S--): Carbonate (CO3--): Hydroxide (OH-): Bisulfide (HS-): Ionic Strength: Oxygen: Water analyses at inlet Sulfur: User specified (in-situ) pH: Ionic Strength: Oxygen: Water analyses at outlet Sulfur: User specified (in-situ) pH: Type: Inhibition Details Efficiency: None (<25%) NO NO No Treatment NO NO 0M 0 ppb 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0 ppm 0M 0 ppb

Pipe Details Diameter: Geometry: Length: Angle of Inclination: Application Details: Corrosion Allowance: --------------- Continued --------------8,01 cm 10000 m 0 degrees 3 mm

Created On: 17.05.2012 15:12:20

Stream132012517142053.pdf

Page 3 of 7

Pipe Details Service Life: Calculate Surface Tension: Surface Tension: Surface Details: Use Custom Roughness: Roughness: NO Wrought Iron (0.0018) 20 years NO 25,05 dyne/cm

Horizontal Flow User Dew Point Data: Specify Dew Point: Production Rate: Water: Viscosity: Density: Production Rate: Gas: Viscosity: Specific Gravity: Production Rate: Viscosity: Oil: Density: Oil Type: 690 kg/m3 Not Persistent NO 1,289 m3/d 1,16 cp 1015,5 kg/m3 0,002 Mm3/d (standard) 0,012 cp 0,4 (air = 1.0) 0,664 m3/d 0,46 cp

Created On: 17.05.2012 15:12:20

Stream132012517142053.pdf

Page 4 of 7

Flow Results (Inlet) GOR: WGR: Water Cut: Superficial Liquid Velocity: Fluid Properties: Superficial Gas Velocity: Mixture Velocity: Froude No: Reynold No: Liquid Hold-up: Pressure Drop: Fluid Results: Wall Shear Stress: Flow Regime: 0,005 Pa Horizontal - Stratified Flow 0,513 m/s 0,518 m/s 0,341 2503,659 0,108 0 bar/m 2306,25 m3/m3 842,12 m3/Mm3 N.A. 0,004 m/s

Results (Inlet) Pitting Probability: Corrosion Index: System pH: Is Scale Protection (FeCO3 and FeS) Applied: FeCO3 pH: FeS pH: Results: Dew Point: Total Water: Water Fraction: Vapor Fraction: NA 0,26 mmpy 4,521 YES

4,922 N.A. 165,557 C 1,292 m3/d 99,79% 0,21% The specified corrosion allowance translates to a corrosion rate less than the predicted corrosion rate. Hence the projected life of the steel will be less than the desired service life.

Description:

Created On: 17.05.2012 15:12:20

Stream132012517142053.pdf

Page 5 of 7

Results (Outlet) GOR: WGR: Water Cut: Superficial Liquid Velocity: Fluid Properties: Superficial Gas Velocity: Mixture Velocity: Froude No: Reynold No: Liquid Hold-up: Pressure Drop: Fluid Results: Wall Shear Stress: Flow Regime: 0,005 Pa Horizontal - Stratified Flow 0,513 m/s 0,518 m/s 0,341 2503,659 0,108 0 bar/m 2306,25 m3/m3 842,12 m3/Mm3 N.A. 0,004 m/s

Flow Results (Outlet) Pitting Probability: Corrosion Index: System pH: Is Scale Protection (FeCO3 and FeS) Applied: FeCO3 pH: FeS pH: Results: Dew Point: Total Water: Water Fraction: Vapor Fraction: NA 0,26 mmpy 4,521 YES

4,922 N.A. 165,557 C 1,292 m3/d 99,79% 0,21% The specified corrosion allowance translates to a corrosion rate less than the predicted corrosion rate. Hence the projected life of the steel will be less than the desired service life.

Description:

Created On: 17.05.2012 15:12:20

Stream132012517142053.pdf

Page 6 of 7

Corrosion Profile

Created On: 17.05.2012 15:12:20

Stream132012517142053.pdf

Page 7 of 7

Anda mungkin juga menyukai