Anda di halaman 1dari 8

Oildyne

108 Series Hydraulic Power Units


Pressures to 241 bar (3500 psi) Flows to 2.8 lpm ( 3/4 gpm)

Catalog HY22-1121/US

features

Hydraulic Power Units 108 Series

Typical applications
Positioning Hydraulic door operators Conveyor belt tensioners Medical chairs, beds, and equipment recreational Vehicles Leveling Slideouts Tent Trailers clamping Tool fixtures and jigs Hydraulic brakes Crimping tools Arbor presses Truck restraints cycling Garbage compactors Valve operators Press controls Packing equipment Indexing tables lifting Handicap lifts Scissor lift tables Pallet movers

108 Series Self-contained Hydraulic Power Units


Our compact 108 Series power units let you put the power where you need it. Theyre completely self-contained with an AC or DC motor, gear pump, reservoir, internal valving, load hold checks and relief valves. The 108 Series models are designed for intermittent service and come in four standard pump sizes which produce flows of .0098, .0187, .0246, and .0321 cubic inches per revolution. Locking check valves are available in all models. Performance will vary with the type of fluid used. Several hydraulic circuits are available. 108 Series units are available with single- or bi-directional rotation. Single units are commonly used to charge accumulators, power one-direction hydraulic motors and cylinders, provide pilot flow to servo valves, pressurize lube systems and supply multifunction circuits with external valving. Bi-directional, reversible units operate double-acting cylinders and two-way motors. Wed like to work with you on your special hydraulic applications. Our people know small hydraulics. We know how to design them, how to make them and how to apply them. Therefore, we can offer you a practical, economical solution to your fluid power problems. Oildyne has pioneered top quality, compact hydraulic components since 1955. We can provide standard products or custom design high pressure, space saving solutions to your specific needs.

Parker Hannifin Corporation Oildyne Division Minneapolis, MN 55428 USA

Catalog HY22-1121/US

technical Information

Hydraulic Power Units 108 Series

108 SERIES POWER Standard Product Ordering CodeUNIT 108


108 POWER UNIT - includes relief valve(s) MOTOR CODE 12 vdc Permanent Magnet 12 vdc Series Wound 24 vdc Permanent Magnet 24 vdc Series Wound 115 vac, 1 phase, Open 230 vac, 1 phase, Open 36 vdc Permanent Magnet S C PUMP TYPE Standard Cold Temp PUMP SIZE 10 .0098 CIPR 19 .0187 CIPR 25 .0249 CIPR 32 .0321 CIPR RESERVOIR 26 cu. in. (13 cu. in. usable) 46 cu. in. (23 cu. in. usable) 46 cu. in. (26 cu. in. usable) Alternate orientation version of C 122 cu. in. (82 cu. in. usable) 69 cu. in. (46 cu. in. usable) 1/2 gallon usable 1 gallon usable 1-1/2 gallon usable 1/4 gal. usable (plastic) 1/2 gal. usable (plastic) 1 gal. usable (plastic) 3/4 gal. usable (plastic)

STANDARD ORDERING CODE

AE AM BE BI HA HD IA

DN RV SETTING (Right Hand Port) Use 00 for Single Dir. In multiples of 100 psi Examples 04 = 400 psi 12 = 1200 psi 29 = 2900 psi UP RV SETTING (Left Hand Port) In multiples of 100 psi Examples 04 = 400 psi 12 = 1200 psi 29 = 2900 psi MOUNTING Vertical (motor up) Horizontal

V H

A B C D F G H I J P Q R S

1 2 3 4 NN WW RR LL RB LB S1 S2 S3 S4 S5 S6 S7 S8

PORTS 7/16-20 (SAE -4) 7/16-24 (Inv. Flare) 1/8" Pipe (NPSF) 1/8" Pipe (BSPP)

NOTES: C and D reservoirs are available as Vertical Mount ONLY. A reservoir with pump 32 is available ONLY as vertical mount.

CIRCUIT TYPE Single direction Single direction with check Reversible Reversible locking Reversible with Back Pressure Reversible locking with Back Pressure Each Solenoid Valve option below includes the WW circuit: 12 vdc, Normally Closed 24 vdc, Normally Closed 120 vac, Normally Closed 240 vac, Normally Closed 12 vdc, Normally Open 24 vdc, Normally Open 120 vac, Normally Open 240 vac, Normally Open

ORDERING CODE INSTRUCTIONS Select the model code needed based on catalog information. All boxes above must be filled in before Oildyne can process the order. If the power unit is a single direction unit use '00' for the DN (Right Hand) relief valve box.

Hydraulic Fluid
ATF, OD18, or other clean hydraulic oil with a viscosity of 150 to 300 SUS at 38C (100F) is acceptable. If another type of fluid is needed, please consult the factory.

Temperature Range
Normal operating range is +20F to +140F. Please review your application with the factory for uses below -7C and over +60C (+20F and over +140F).

ALL DATA SUBJECT TO CHANGE WITHOUT NOTICE FOR POWER UNIT CONFIGURATIONS OTHER THAN THOSE SHOWN PLEASE CONSULT OILDYNE.

Parker Hannifin Corporation Oildyne Division Minneapolis, MN 55428 USA

Catalog HY22-1121/US

technical Information

Hydraulic Power Units 108 Series

12/24 V DC Permanent Magnet Motor Code AE BE


Motor type: ae and Be
For intermittent duty cycles.

wiring diagram: ae Be

.100 Pump (.0098 cipr)


with AE / BE Motor

-12 VDC SUPPLY (AE) -24 VDC SUPPLY (BE) +12 VDC SUPPLY (AE) +24 VDC SUPPLY (BE)

Output Flow - lpm (cipm)

DPDT CENTER OFF TOGGLE SWITCH

.82 (50) .66 (40)

25

Current - Amps

20 Flow

LEFT HAND PORT GREEN OR ORANGE MOTOR LEAD

RIGHT HAND PORT BLUE OR BLACK MOTOR LEAD

.49 (30) .33 (20) .16 (10) 0 0 Current @ 24 VDC

Current @ 12 VDC

15

10

MOTOR

DPDT CENTER OFF TOGGLE SWITCH USABLE UP TO 20 AMPS @ 12 VDC

0 69 34 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000)

Pressure - bar (psi)

12/24 V DC Series Wound Motor Code AM BI


Motor type: aM and BI
For intermittent duty cycles.

wiring diagram: aM BI
SPDT CENTER OFF TOGGLE SWITCH LEFT HAND PORT SOL SWITCH 1 RIGHT HAND PORT SOL 2 SWITCH

.100 Pump (.0098 cipr)


with AM / BI Motor
Flow Current @ 12 VDC 36 60

Output Flow - lpm (cipm)

+12 VDC SUPPLY (AM) +24 VDC SUPPLY (BI)

-12 VDC SUPPLY (AM) -24 VDC SUPPLY (BI)

1.6 (100) 1.3 (80) .98 (60) .66 (40) .33 (20) 0 0

Current - Amps

48

24

SOL 1 SWITCH CONTACTS BLUE MOTOR LEAD

SOL 2 SWITCH CONTACTS GREEN MOTOR LEAD BLACK MOTOR LEAD MOTOR

Current @ 24 VDC

12

0 34 69 103 138 172 207 241 (500) (1000) (1500) (2000) (2500) (3000) (3500)

NOTES: AM MOTOR HAS 100 AMP THERMAL BREAKER; BI MOTOR HAS 50 AMP THERMAL BREAKER.

Pressure - bar (psi)

115/230 V AC Capacitor Start Motor Code HA HD


Motor type: Ha and Hd

.100 Pump (.0098 cipr)


with HA / HD Motor
Current @ 115 VAC Flow

115 VOLTAGE CONNECTION

BLUE WHITE BLACK GREEN/YELLOW MOTOR RED YELLOW ORANGE 7 AMP

B R O W N

3 2 RELAY 4 L-2 161-193 MFD/125V L-1

Output Flow - lpm (cipm)

Dual voltage 1/3 HP, 60/50 hz, 3450/2850 rpm, intermittent duty, single phase, open frame. Capacitor and relay included.

wiring diagram: Ha

.82 (50) .66 (40) .49 (30) .33 (20) .16 (10) 0 0

Current - Amps

TO REVERSE, INTERCHANGE RED AND BLACK LEADS

wiring diagram: Hd
230 VOLTAGE CONNECTION

Current @ 230 VAC

WHITE BLACK GREEN/YELLOW BLUE MOTOR ORANGE RED YELLOW 3 AMP

B R O W N

2 3 RELAY 4 L-2 161-193 MFD/230V L-1

0 69 34 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000)

Pressure - bar (psi)

note: 50 hz performance is 83% of curves shown.

Parker Hannifin Corporation Oildyne Division Minneapolis, MN 55428 USA

Catalog HY22-1121/US

technical Information

Hydraulic Power Units 108 Series


Performance data based on ATF @ 21C ( 70F)

.190 Pump (.0187 cipr)


Output Flow - lpm (cipm) Output Flow - lpm (cipm)
1.2 (75) .98 (60) Flow .74 (45) .49 (30) .25 (15) 0 0 Current @ 12 VDC

with AE / BE Motor

.250 Pump (.0246 cipr)


Flow

Output Flow - lpm (cipm)

50

1.6 (100) 1.3 (80) .98 (60) .66 (40) .33 (20) 0 0

with AE / BE Motor

.327 Pump (.0321 cipr)


50

2.5 (150)

with AE / BE Motor

50

Current - Amps

Current - Amps

Current - Amps

40

40 Current @ 12 VDC 30

2.0 (120) Flow 1.5 (90) .98 (60) .49 (30) Current @ 24 VDC

Current @ 12 VDC

40

30

30

20

20

20

Current @ 24 VDC

10

Current @ 24 VDC

10

10

0 69 34 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000)

Pressure - bar (psi)

0 69 34 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000)

Pressure - bar (psi)

Pressure - bar (psi)

34 (500)

69 (1000)

103 (1500)

0 138 (2000)

.190 Pump (.0187 cipr)


Output Flow - lpm (cipm)

Output Flow - lpm (cipm)

Output Flow - lpm (cipm)

2.5 (150) 2.0 (120) 1.5 (90) .98 (60) .49 (30) 0 0

with AM / BI Motor
Flow Current @ 12 VDC

.250 Pump (.0246 cipr)


75

3.3 (200) 2.6 (160) 2.0 (120) 1.3 (80) .66 (40) 0 0

with AM / BI Motor

.327 Pump (.0321 cipr)


100
4.1 (250) 3.3 (200) 2.5 (150) 1.6 (100) .82 (50) 0 0 34 (500) Current @ 24 VDC Current @ 12 VDC

with AM / BI Motor

100

Flow 80

Flow

Current - Amps

Current - Amps

Current - Amps

60

80

45

Current @ 12 VDC

60

60

30

40

40

Current @ 24 VDC

15

Current @ 24 VDC

20

20

0 34 69 103 138 172 207 241 (500) (1000) (1500) (2000) (2500) (3000) (3500)

Pressure - bar (psi)

0 69 103 138 172 207 34 (500) (1000) (1500) (2000) (2500) (3000)

Pressure - bar (psi)

Pressure - bar (psi)

0 172 69 103 138 (1000) (1500) (2000) (2500)

.190 Pump (.0187 cipr)


Output Flow - lpm (cipm)

Output Flow - lpm (cipm)

Output Flow - lpm (cipm)

1.6 (100) 1.3 (80)

with HA / HD Motor

.250 Pump (.0246 cipr)


10

1.6 (100) 1.3 (80) .98 (60) .66 (40) .33 (20) 0 0

with HA / HD Motor

.327 Pump (.0321 cipr)


10

2.0 (125) 1.6 (100) 1.3 (75) .82 (50) .41 (25) 0 0

with HA / HD Motor
Flow

Flow 8

Current - Amps

Current - Amps

Current - Amps

8 Flow

5 Current @ 115 VAC

.98 (60) .66 (40) .33 (20) 0 0 Current @ 115 VAC

6 Current @ 115 VAC

3 Current @ 230 VAC

Current @ 230 VAC

2 Current @ 230 VAC 0 69 34 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000)

0 69 34 103 138 172 207 (500) (1000) (1500) (2000) (2500) (3000)

Pressure - bar (psi)

Pressure - bar (psi)

1 41 62 83 103 124 21 (300) (600) (900) (1200) (1500) (1800)

Pressure - bar (psi)

note: Performance data is for reference only.

Parker Hannifin Corporation Oildyne Division Minneapolis, MN 55428 USA

Catalog HY22-1121/US

circuits

Hydraulic Power Units 108 Series

UP TRV

DN UP DN

RV

RV

WW CIRCUIT

NN CIRCUIT

UP TRV

Thermal Relief Valves Why?

The thermal relief valves (TRV) purpose is to allow a bleed off of built up pressure due to thermal expansion of the fluid or to act as a (limited) shock load protection, should a cylinder in the system get bumped. The thermal relief valve is included in circuits using a pilot operated check valve. The single direction units get one; the reversing units get two. It is located between the check valve and the 108 Series pump outlet port. It is a fixed relief valve with a pressure setting approximately 100-140 bar (1500-2000 psi) above the system relief valve pressure.

RV

S* CIRCUIT
8
Parker Hannifin Corporation Oildyne Division Minneapolis, MN 55428 USA

Catalog HY22-1121/US

circuits

Hydraulic Power Units 108 Series

UP UP DN
BACK PRESSURE CIRCUIT

DN

HPRV

LPRV

HPRV

LPRV

RR CIRCUIT

RB CIRCUIT

UP TRV UP TRV DN TRV

DN TRV

BACK PRESSURE CIRCUIT

HPRV

LPRV

HPRV

LPRV

LL CIRCUIT

LB CIRCUIT

Back Pressure Circuits Why?

The basic reversible circuit is essentially a closed loop. The oil returning from the system is fed back into the pump inlet. When a cylinder is being retracted more oil is being returned to the power unit than is leaving it due to the rod volume. This results in the DN side relief valve cracking open allowing the rod volume of oil to go back to the tank. The larger the rod volume the more open the relief valve will be. In many applications this is not a problem. However, if work is being done on the retract stroke, or if a pressure switch is used to signal the cylinder is fully retracted, the back pressure circuit is required. This circuit allows the rod volume of

oil to return to the reservoir through a special shuttle spool, before it reaches the pump. Full relief valve pressure is then available to retract the cylinder, also preventing a pressure switch from tripping before the full retract position is achieved. Recommended uses: In systems where work is being done on the retract stroke Where a pressure switch is used to signal the full retract position In systems requiring a faster retract than extend speed

Parker Hannifin Corporation Oildyne Division Minneapolis, MN 55428 USA

Catalog HY22-1121/US

dimensions

Hydraulic Power Units 108 Series

Overall Dimensions
FRONT VIEW SIDE VIEW A STANDARD RESERVOIR ORIENTATION IS SHOWN ALTERNATE ORIENTATION WOULD HAVE FILLER CAP ON LEFT SIDE (IN FRONT VIEW) BACK VIEW 112.8 (4.44)

PORT SIZE SEE CODING RESERVOIR FILLER CAP 30.7 (1.21)

THIRD ANGLE PROJECTION

MAX MIN

MAX MIN

85.3 (3.36) 46 CU IN RESERVOIR 2 MOUNTING HOLES 3/8-16 UNC-2B X 7/16 DP.

29.2 (1.15)

29.2 (1.15)

149.4 (5.88) 97.3 (3.83)

29.4 (1.16)

29.4 (1.16)

with Solenoid
7/16-20 PRESSURE PORT UNUSED PRESSURE PORT PLUG RESERVOIR FILLER CAP SOLENOID VALVE

64.9 (2.55)

75.40.8 (2.97.03) 12 VDC MOTOR

126.2 (4.97)

30.7 (1.21)

83.81.5 (3.30.06)

Motor dimensions .1.3 (.050) A B C 126.2 241.3 AE/BE 75.4 (2.97) (4.97) (9.50) 95.8 151.4 266.4 AM/BI (3.77) (5.96) (10.49) 75.4 128.8 244.1 IA (2.97) (5.07) (9.61) 161.0 276.4 HA/HD 100.1 (3.94) (6.34) (10.88)

29.2 (1.15)

29.2 (1.15)

141.71.5 (5.58.06)

1.270.8 (.05.03)

Note: All dimensions in mm (inches).

Reservoir Dimensions
162.1 (6.38) 123.8 (4.88)
8

Note: refer to page 17 for information on the P, Q, R and S reservoirs.


80.3 (3.16) 161.0 (6.34) 93.9 (3.70)

149.4 (5.88)

HDPE

91.2 (3.59) 93.9 (3.70) 46 CU. IN. (23 CU. IN. USABLE) ALUMINUM (754 CC: 377 CC USABLE)

28 CU. IN. (13 CU. IN. USABLE) ALUMINUM (459 CC: 213 CC USABLE)

A RESERVOIR

B RESERVOIR

101.6 (4.00)

85.3 (3.36)

"G" RESERVOIR
#3-69 CU. IN. (46 CU. IN. USABLE) EXTRUDED ALUMINUM (1130 CC: 754 USABLE)

46 CU. IN. (26 CU. IN. USABLE) HIGH DENSITY POLYETHYLENE WITH UV ADDITIVE STD. (754 CC: 426 CC USABLE) 266.7 (10.50)

C RESERVOIR

175.3 (6-7/8)

H 1/2 GAL
(2 Liter)

I 1.0 GAL
(4 Liter)

J 1.5 GAL
(5.6 Liter)

142.3 (5.60)

101.6 (4.00)

"H,H,, I, JRESERVOIR -STEEL I J" RESERVOIR STEEL


"F" RESERVOIR
122 CU. IN. (82 CU. IN. USABLE) STEEL (2000 CC: 1344 CC USABLE)

184.6 (7.27)

311.7 (12.27)

413.3 (16.27)

10

Parker Hannifin Corporation Oildyne Division Minneapolis, MN 55428 USA

Anda mungkin juga menyukai