Catalog Overview
R_PSPOC Parameter
R_PSTIMER
Overview
Network optimization
Adjustment & validation Optimization scheme implementation
performance
optimize resource configuration
Overview
Overview
QOS
Overview
Reliability class
Delay class
Qos priority
QOS
Average throughput
Overview
System message 1
System message 2
System message 3
System message
System message 4
System message 5
System message 13
Catalog Overview
R_PSPOC Parameters
R_PSTIMER
BVC flow control triggering threshold. BVC flow control is carried out on DL in Gb interface, BSS providing
80 by default
In BVC power control flow control, BVC leakage ratio statistics period is also called BVC long measurement period. In order to provide reference for BVC flow control in SGSN, BSSGP procedure make periodic statistic of leakage ratio of BVC; when long measurement timer overflows, BVC flow control process will be initiated and if the difference between forward and after leak rate exceed CellFcThs, it needs SGSN confirmation;
When short statistics timer overflows, and the different between the forward and
after leak rates exceeds CellFcThs, BVC flow control process will be initiated and wait for confirmation by SGSN.
value1~100% setting
80 by default
resource lack.
value1~100% setting
80 by default
In MS power control process, MS leakage rate statistics period is also called MS long measurement period. In order to provide reference for flow control in SGSN, BSSGP procedure makes periodic statistic of leakage ratio of MS. when long statistics timer overflows, MS flow control process will be initiated and if the difference between forward and after leakage ratio exceeds CellFcThs, it needs SGSN confirmation When short measurement timer overflows, and the different between the forward
and after leak rates exceeds MsFcThs, MS flow control process will be initiated and
wait for confirmation by SGSN.
value1~100% setting
80 by default
There are different modes in BSC, through which power control parameters is reported to SGSN. The modes are as follows: Mode 1report power control parameters based on flow on radio interface recorded by BSC. Mode 2report flow control parameters according to maximum flow allowed by the cell; Mode 3
value1~100%
setting
80 by default
Parameter used in MS( belonging to GPRS cell parameters) is broadcasted to MS in messages of PSI1, PSI13 and SI13 indicating network operation mode in the cell. The network operation modes are as follows: Network operation mode 1 Network operation mode 2 Network operation mode 3
setting1 by defaultnetwork operation mode 2
value 0 1 2 3 connotation Network operation mode1 Network operation mode 2 Network operation mode 3 unused
note MNO of cell in one RAC shall be the same; Gs interface has effect on the selection of NMO.
N3101, counter T3169 will start; When T3169 exhausts, TFI and USF can be used again. BS MS S value 9~255
USF=n USF=n
Setting:
10 by default
. .
USF=n
N3101max
RlacMac_T3169
0~255 10 by default
setting
. .
N3103max
RlcMac_T3169
Release USF and TFI
resource.
value
0~255 10 by default
. .
Data BlockRRBP PACK DLLINK ACK/NACK
N3105max
setting
RlcMac_T3195
Release TFI
Catalog Overview
R_PSPOC Parameters
R_PSTIMER
In BSSGP layer, for management conveniences, each GPRS cell is given a BVC(NSEI+BVCI) which is affiliated to one NSE.
by the operator
Generally, one BSC is considered to be an independent service entity containing several NSE in ZXG10 system.
sketch:
LSP1 LSPn LSP1 LSPn
BVC1 BVCn
BVC1 BVCn
NSE
NSE
FR Net
BSC
SGSN
corresponding entities.
value0~65535(0:
function entity)
setting
configured by the operator one NSE, each GPRS cell can be identified by one BVCI.
remarkin
Similar to GSM system, LAC is applied in GPRS system to manage a group of cells; whats more, LAC is divided into RAC which are identified by
T3168
description
by default(4.0 second)
value 0 1 2 7
4.0 sec.
T3192
description
Parameter used in MS. In packet DL transmission process, if pending RLC data block is the last
DL data block, the network will initialize DL TBF release through sending a
RLC data block, of which FBI is 1, and containing a valid RRBP field.
setting0500ms
remarkthe time length which T3192 represents shall be less than the time length of T3193(protecting DL TBF) so as to ensure the exclusiveness of TFI.
T3192
influence
The greater the value of the parameter is, the longer TBF relative resource (including TFI and timeslot) will be reserved. Similarly, TBF sending time will be longer which will easily lead to congestion. The smaller the value of the parameter is, the longer DL TBF establishment will be. Because MS will release
value 0 1 2 3 4 5 6 7 Time length represents unitms) 500 1000 1500 0 80 120 160 200
T3192
Signaling
Procedure Sketch:
BS S
BS S
MS
Data Block
MS
Data Block
Data BlockRRBP,FBI=1
Data BlockRRBP,FBI=1
< RlcMac_T3191
< RlcMac_T3191
T3192
T3192
Release resource
Release resource
Ack Mode
Non-ack mode
Parameters used in MS, which is a GPRS cell optional parameter and broadcast to MS in PSI1, PSI13 and SI13 indicating DRX_TIMER_MAX value. When MS mode changes from packet transmission to packet idle (also called non-DRX), the time that MS stay non-DRX is decided by minimum of NON_DRX_TIMER and DRX_TIMER_MAX.
setting2 by default
Value
0 1 2 3 7 64 sec.2(7-1) sec.
Time length
0 sec. 1sec.2(1-1)sec. 2 sec.2(2-1) sec. 4 sec.2(3-1) sec.
In non-DRX mode, MS will monitor CCCH blocks, and PCU will contain context concerning MS. Immediate assignment messages about DL TBF establishment can be sent on AGCH in stead of making paging.
Non-DRX mode will help to shorten DL TBF establishment, which will also
quicken the consumption of battery.
Setting:15300ms influence
If BS_CV_MAX is set to be too small, RLC data block may be retransmitted before ack message is received, which will result in the high occupancy rate of radio resource; If BS_CV_MAX is too highly set, the efficiency of the sliding window may
value
connotation
0 1 2 15
They are GPRS cell optional parameters used in MS which are broadcast in messages of PSI1, PSI13 and SI13, indicating the value of PAN_DEC,
settingPanDec0,PanInc1),
To add PANMAX and PANINC, and reduce PANDEC will reduce the possibilities of cell reselection due to TBF abnormal release when MS cant receiving Packet Uplink Ack; at the same time, MS sending window will pause and occupy radio resources for a long time which is the source of inefficiency of radio utility rate. To reduce PANMAX and PANINC, and add PANDEC will easily lead to cell reselection due to TBF abnormal release, reduce TBF normal release rate and affect data transferring rate.
PanMax value 0 1 2 7 Value represents 4 8 12 32
Parameters used in MS Is a PCCCH structural parameter and is broadcast to MS in PSI1 This parameters indicates the number of 52 multiframe(12 blocks) assigned to be PBCCCH. PBCCH is used by packet system messages sent at high-speed and low speed. This parameter shall be configured with PSI1_REPEAT_PERIOD in PSI1 message to ensure the availability of blocks to send messages both at high speed and low speed.
Setting:
value 0 1 2 3 connotation PBCCH uses 1 block in multiframe PBCCH uses 2 blocks in multiframe PBCCH uses 3 blocks in multiframe PBCCH uses 4 blocks in multiframe
0 by default
setting5 by default
Value 0 1 12 13~15 Block reserved for PAGCH, PDTCH and PACCH is 12 The same with 0 Connotation Block reserved for PAGCH, PDTCH and PACCH is 0 Block reserved for PAGCH, PDTCH and PACCH is 1
12 13~15
PRACH
Setting:
2 by default(4 timeslots)
7
8 9 10~15
S=109
S=163 S=217 reserved
setting2
by default
value
this parameter is an array, array element is 4, the first array element corresponds to the maximum
0
1 2 3
Once allowed
Twice allowed 4 times allowed 7 times allowed
2 by default(4 timeslot)
value
0 1 2 3 4 5 6 7
connotation
Non-DRX 0.24 sec. 0.48 sec. 0.72 sec. 0.96 sec. 1.20 sec. 1.44 sec. 1.92 sec.
Number
description
Is a parameter used in DBS in Pn Indicates minimum number of CS idle channels when PS+CS channels is change to be PS channels. If idle CS channel number is lower than the minimum number, dynamic PS+CS channel cant be changed to be PS channel; and vice versa.
value:
0~255 2 by default
Setting:
50 by default
Catalog Overview
R_PSPOC Parameters
R_PSTIMER
C1RXLEV-GPRS_RXLEV_ACCESS_MINMAX(GPRS_MS_TXPWR_MAX_CCH-P,O)
of MS (unit: dBm)
arithmetic formula:
GPRS_TEMPORARY_OFFSET*H(GPRS_PENALTY_TIME-T)*L (adjacent
cell) PRIORITY_CLASS (service cellPRIORITY_CLASS (adjacent cellL=0 PRIORITY_CLASS (service cellnot equal to PRIORITY_CLASS (adjacent
cellL=1
arithmetic
To select the cell among the cells with the same level priority, the following formula are used: C32=C1(serving cell C32=C1+GPRS_RESELECT_OFFSETGPRS_TEMPORARY_OFFSET*H(GPRS_PENALTY_TIME-T)*(1-L)(adjacent cell When MS is in ready state and serving cell has the same RAC with the adjacent cell,
C32=C32+GPRS_CELL_RESELECT_HYSTERESIS
When MS is in standby or ready state and serving cell has different RAC with the adjacent cell, C32=C32+RA_RESELECT_HYSTERESIS When MS is in standby state and serving cell has different RAC with the adjacent cell C32=C32
Is a parameter used in MS. Is broadcast to MS in PSI3. In GPRS, C32 is used for cell reselection. Similar to C2 in GSM, cell reselection offset (ReselOff) is used in C32 arithmetic. When ReselOff is 0dB, message will not be sent.
setting0dB by default
value 0 1 10 11 22 23 31 Relative power level -52 dB -48 dB -12dB -10dB +12dB +16dB +48 dB
Is parameter used in MS
Is broadcast in PSI3.
When cell selection is made, and LAC of the source cell and target cell is found to be different, a location update shall be initiated.
settingReselHys
is generally set to be 4 or 5
Value 0 1 2 3 4 5 6
14 dB
Is a parameter used in MS Is broadcast in PSI3 and indicates whether ReselHys is available in C31.
Value0 unavailable
1 available
Setting:
value0
not allowed
1 allowed
setting
0 by default
by default5 sec.
value 0 1 2 3 4 5
6
7
120
300
7 by default
value 0 1 2 3 4 5 6
of GSM system.
infinite
0 by default
value 0 1 31 Time represents 10 sec. 20 sec. 320 sec.
Catalog Overview
R_PSPOC Parameters
R_PSTIMER
R_PSPOC Parameters
Is a parameter used in MS. Is a power control parameter of the network and is broadcast in PSI1, PSI13 andSI13. GPRS This parameter decides of MS transmitting power control. MS transmitting power is decided by the following formula: P =min0 - CH a (C + 48)PMAX
setting0 by default
value connotation
0
1 2 9
=0.0
=0.1 =0.2
=0.9
10
11~15
=1.0
The same with 10
R_PSPOC Parameters
Is a parameter used in MS. Is a power control parameter of BSC and GPRS system and is broadcast in PSI1, PSI13 and SI13. This parameter is a period of signaling strength filterconnotation idle mode. in packet value
setting
0 by default
0 1
25 26~31
R_PSPOC Parameters
Is a parameter used in MS. Is a power control parameter in BSC and GPRS system and is broadcast
by default
0 1
25 26~31
reserved
R_PSPOC Parameters
Is a parameter used in MS. Is a power control parameter in BSC and GPRS system and is broadcast in PSI1, PSI13 and SI13. It indicates DL power strength measurement location for UL power control purpose.
setting0
by default
value 0 1 connotation DL measurement in BCCH for power control DL measurement in PDCH for power control
R_PSPOC Parameters
Is a parameter used in MS
Is a power control parameter in BSC and GPRS system and is broadcast in PSI1, PSI13 and SI13. It a constant to filter interference signaling for power control.
setting0 by default
value
0
connotation
Filter constant 2(0/2)
15 Filter constant
R_PSPOC Parameters
setting0 by default
value 0 1 2
UL Power control strategy Not controlled Open-loop control Closed loop control
3
other
Based o quality
reserved
R_PSPOC Parameters
Is a parameter used in MS. Is a power control parameter of BSC and GPRS system and is broadcast
by default
R_PSPOC Parameters
by default
value 0 1 2
DL Power control stategy Not controlled Open-loop control Closed loop control
3
other
Based o quality
reserved
Catalog Overview
R_PSPOC Parameters
R_PS Timer
R_PS Timer
T3169
description
Timer start condition: when N3101 = N3101max, or N3103 = N3103max. Timer stop condition: no
setting
R_PS Timer
T3191
description
In packet DL transmission process, if pending RLC data block BSN is the biggest, the network will initialize DL TBF release through sending a RLC data block, of which FBI is 1, and containing a valid RRBP field. T3191 will be started then. The following is processing flow in non-ack mode. Processing flow in ack mode is silimar.
MS
Data Block
BS S
MS
Data Block
BS S
Data BlockRRBP,FBI=1
Data BlockRRBP,FBI=1
< RlcMac_T3191
RlcMac_T3191
RlcMac_T3193
Release TBF
Release TBF
R_PS Timer
T3191
description
Timer start condition: when the last RLC data block is sent (FBI is marked by 1).
0~0xFFFF10ms
500 by default(5 sec.
setting
R_PS Timer
T3193
description
Timer starting condition: when last PACKET DOWNLINK ACK/NACK or PACKET CONTROL ACKNOWLEDGE message is received.
setting
R_PS Timer
T3195
description
Its TBF protecting time when radio link fails or MS doesn t respond due to cell change. In packet DL transmitting process, if N3105 expires
BSS will start T3195; when T3195 gets exhausted, TFI can be used
again. timer starting condition: N3105 = N3105max. timer stop condition: no expire indication: release TFI
value
setting