Kaizen Presentation
Kaizen
Organization
JQM
Market Leader Farm Equipment Sectorin Indian Tractor Industry since last 25 years Third position in Global Tractor Market Products Engines & Tractors
Organization Achievement
JQM
TS-16949-2002
QS 9000 - 2000 ISO9001 - 1996
Name of Members :Mr. Sameer Tambe Mr. Amol Berde Mr. Yogesh Kale
Contents
JQM
Background
Old System set up Problem Definition Need of Kaizen Why Why Analysis Root Cause Methodology New System Set up Result
Benefits
6
Background
JQM
Diesel Engine Exhaust Emission consist of major pollutants like NOx, HC, CO, & PM
Gases with various known concentration levels are being used in Emission analyzer
Background
JQM
1. Operating gases - XL Grade O2, XL Grade Zero Air, XL Grade N2, H2 + HE - Continuously in use
2. Calibrating gases - Propane + N2, NO + N2, CO + N2, Co2 +N2 - One time use
*** Each Calibrating gas has two ranges of Concentration i.e. Low & high PPM levels
Old System
JQM
Control room
100 80 60 40 20 0
Gas bottle
Emission analyzer
Background
JQM
Old System
Pressure regulator
10
11
Problem Definition
JQM
Farm Equipment Sector - Location of the Gas bottles are away from the Lab
Corridor ( as per safety standard ) - Gas bottle getting emptied without any indication surprise to Engineer
LEADING TO..
Need of Kaizen
JQM
89 82 68 70 60 72
Avg. 73.5 %
% Utilization
70 60 50 40 30
20
10 0 Jan-07 Feb-07 Mar-07 Month Apr-07 May-07 Jun-07
13
Need of Kaizen
JQM
No man power 2%
OEE 73%
No man power Engine not received Break down Gas bottles not received OEE
14
Need of Kaizen
JQM
% Split up No man power : 2 % Engine not received : 3 % Break down : 5 % Gas bottles not available : 16.5 %
15
Not Ordered
Why
No Intimation
Why
No Early Warning
16
Root Cause
JQM
Methodology
JQM
Concept development
Selection of components
System set up
18
Indication System
JQM
1 5
2 6
3 7
4 8
Control room
100 80 60 40 20 0
Alarm .
Gas bottle
Emission analyzer
19
Indication System
JQM
20
Indication System
JQM
21
Indication System
JQM
22
Indication System
JQM
- Set pressure for each gas bottle considering Lead time, utilization & no of tests
Identification no
1 2 3 4 5 6 7 8 Bottle Propane + N2 NO + N2 CO + N2 Co2 +N2 XL Grade O2 XL Grade Zero Air XL Grade N2 H2 + HE
Set Pressure
20 40 20 20 30 30 30 30
Result
JQM
85.0 73.5
60 40 20 0 Before After
24
Tangible Benefits
JQM
1. Place order for gas bottle in advance 2. Achieve uninterrupted Emission test 3. Cost saving
25
Intangible Benefits
JQM
1. Meet project time lines 2. Enhance test bed utilization 3. Reduce operator fatigue
26
JQM
P.U.: R&D , CELL: For all Test Beds M/C : ETL, Loc 2
Farm Kaizen Equipment Sector Theme : Set up time Idea : Installation of Real time
reduction for Gas bottle system Problem / present Status: pressure indicating system Counter Measure:
KAIZEN SHEET
Kaizen No. : 35 Date : 29/06/07
Bench Mark Target Start Kaizen Finish Team Members : 1. Sameer Tambe 2. Amol Berde 3. Yogesh Kale 5 days 25/06/07 29/06/07
N.A
N.A
Benefits:
Result :
1) OEE schedule adherance improv ed, 2) Achieve project timelines
Achieve uninterrupted emission test OEE schedule adherance improved, Achieve project timelines
PU R&D HORIZONTAL DEPLOYMENT M/C NO. STATUS PU M/C NO. LOC 2 Completed STATUS
27