Anda di halaman 1dari 6

HOW TO IDENTIFY FAN LOCATIONS IN ULTRASITE BTS

For internal use only 1 Nokia Siemens Networks

Steps to Identify the FAN locations in Ultrasite BTS


Identify the FAN related alarm from the MML output (ZEOL) and decode the information from the supplementary field of the alarm text.

Type of Unit slot shelf number rack (cabinet) number Alarm number

In this case:
For internal use only 2 Nokia Siemens Networks

Rack number is 05 Shelf number is 02 Slot number is 05 Type of Unit is 9E which stands for FAN
/

Open the BTS Hardware Configurator from BTS Manager

Match the Rack/Shelf/ Slot info from the MML output in the cabinet units view

For internal use only 3 Nokia Siemens Networks

Identify the particular cabinet unit( PWSx, BB2x, WCGx and TSGx) from the Rack/Shelf/Slot info shown in Cabinet Units View of BTS Hardware Configurator by matching the Rack/Shelf/Slot info decoded from the MML alarm text. In this case it is TRX5(TSGB5).

Hence, the FAN is located corresponding (behind) to TRX5.

Note: FAN behind TRX serves for two TRXs. So, in our scenario the FAN serves for TRX5 and 6. So, troubleshoot accordingly to alarm number as mentioned in NED.

For internal use only 4 Nokia Siemens Networks

All FAN locations in Ultrasite BTS


01/01/03
01/01/01 06/02/01

02/01/01

05/02/01

05/02/03 05/02/05 05/02/07 05/02/09

Legend
05/02/0B Rack/Shelf/Slot 06/02/0C

For internal use only 5 Nokia Siemens Networks

HOW TO RECTIFY/REPLACE
1. Check which fan is giving the alarm from the supplementary information (rack/shelf/slot). 2. If something has jammed the cooling fan unit, remove the jamming object. 3. If the TSxx fan is alarming: . Replace the TSxx in front of the fan. If the fan starts working, the removed TSxx is broken. . If the fan still does not rotate after the first TSxx was replaced, reinsert the original TRX and replace the second TSxx in front of the same fan unit. If the fan starts rotating, the second TSxx is broken. . If the fan does not work after the TSxx removal test, the fan is broken and must be replaced. 4. For other fan alarms, replace the corresponding fan unit. 5. Otherwise, replace the BOI. Note: This alarm is related to fans located in the back of the cabinet.

For internal use only 6 Nokia Siemens Networks