Anda di halaman 1dari 14

System Overview

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.1

SITRAIN Training for


Automation and Drives

Objectives

- Application Possibilities - Forms of Delivery - Core Functions - Architecture

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.2

SITRAIN Training for


Automation and Drives

Customer Benefits

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.3

SITRAIN Training for


Automation and Drives

Application Possibilities of WinCC

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.4

SITRAIN Training for


Automation and Drives

The Basic Functions

Motor ein Ventil geschlossen Klappe zu

anzahl () float zae begin if wert > 0 begom zae = zae + 1 end end

Alarm Logging (Message System)

Programming Interfaces

Process Visualization
Tag Logging (Archiving)
Protokolle

Standard Interfaces

Report Designer (Report System)


SIMATIC HMI
Siemens AG 2003. All rights reserved.

PLC Communication
SITRAIN Training for
Automation and Drives

Date: File:

04.05.2013 swincc01e.5

Licenses and Options


Licenses Options

RC 64,000
Power Tags

64,000
Power Pack (8000)

Runtime 64,000
Power Tags

64,000 Power Pack (8000) 8.000 Power Pack (1024) 1024 Power Pack (256) 256 Power Pack (128)

RC 8000
Power Tags

WinCC Chip card reading function WinCC Allen Bradley DF1 serial WinCC Dat@Monitor (Web_Client)

WinCC Web Navigator

WinCC Redundancy

8.000
Power Pack (1024)

Runtime 8000
Power Tags

RC 1024
Power Tags

Runtime 1024
Power Tags

WinCC ProAgent

WinCC Server

1024
Power Pack (256)

RC 256
Power Tags

Runtime 256
Power Tags

WinCC ODK

WinCC User Archives

RC 128
Power Tags

256
Power Pack (128)

Runtime 128
Power Tags

Runtime + Configuration (RC)

Runtime (RT)

Software

512 archive tags are included in the basic system.

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.6

SITRAIN Training for


Automation and Drives

WinCC Software Protection

WinCC

Installation
Option n
S IE ME N S

SI C O M P

IP C R I 2 0

Option1

De-Installation
WinCC and Multi authorization
No DEFRAG can be performed after the licenses have been installed, since the licenses could thereby be lost. Each WinCC Version has its own authorization.

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.7

SITRAIN Training for


Automation and Drives

System Configurations
Corporate Management Level
Client Client Server 1

PC Network

... Server 12 ...


Distributed systems with Server and Client Multi-user system with Server and Client

Client

Client

Server / R.-Server

Management Level and Production Level


Client Client Server

LAN-Netz Process Supervision Level and Production Management Level Single-user system with PC and OP

SIMATIC NET
SIMATIC WinAC MP

Automation Level

Distributed Peripherals

MPI (not with S5) S5/S7 S505 S5 S7 S505 S5/S7


SITRAIN Training for
Automation and Drives

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.8

Configurations for Single-user Systems

Example 1
COROS OP45

Example 2
Coupling via Network

Serial coupling

WinCC

Point to Point serial V.24 / TTY DK3964R + RK512

MPI (only S7) , SIMATIC NET PROFIBUS SIMATIC NET Industrial Ethernet

SIMATIC S5 / S7 / 505 or PLCs from other manufacturers

SIMATIC S5 / S7 / 505 or PLCs from other manufacturers

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.9

SITRAIN Training for


Automation and Drives

Multi-user System

Client 1

...

Client 32 SIMATIC NET Industrial Ethernet: (S7), S5: TF (Technological Functions) S7: S7 Protocol

Terminal bus (PC Network)


all WinCC applications

all WinCC applications

Server

Red. Server

SIMATIC NET Profibus: (S7), S5: FMS (PROFIBUS) S7: S7 Protocol

SIMATIC NET

SIMATIC 505

SIMATIC S7-400 SIMATIC S5

Note: This WinCC configuration is also used for multi-configuration.

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.10

SITRAIN Training for


Automation and Drives

Distributed Systems / Web Technology


WinCC Web Client
all WinCC applications all WinCC applications

M Client 1

M Client 32

Terminal bus (PC Network)


all WinCC applications

WinCC Web Server


all WinCC applications

all WinCC applications

Server 1

Red. Server

...

Server12

-Technological distribution -Functional distribution -Load distribution

SIMATIC NET

SIMATIC 505

SIMATIC S7-400 SIMATIC S5

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.11

SITRAIN Training for


Automation and Drives

The Architecture

WinCC Explorer System Controller

CS RT

CS RT

CS RT

CS RT

CS RT

CS RT

Graphics

Global Scripting

Alarm Logging

Tag Logging

Report Designer

Option

CS RT

CS

CS

Access Protection

...

RT

TextLibaray

RT

Tag Management Process Data

Data Manager MS 2000 SQL-Server


RT .mdf .mdf S5 S7

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.12

SITRAIN Training for


Automation and Drives

Openness
OPC Client Network

User Programs API Management Analysis Optimization ...

OPC Server

Active X

Graphics OCX

Windows Applications
OLE

Trend Alarm Report

Excel Word ODBC/SQL OLE DB(ADO) Access PowerBuilder ...


DDE

Data Manager
OPC OPC Net Server SIMATIC NET

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.13

SITRAIN Training for


Automation and Drives

Customer Support
Questions on handling selection of products and systems ? Questions on handling products and systems ?

Product Support
Using a SIMATIC AV Card (if in a hurry) Your regional partner in the region/worldwide

No guaranteed response time Principle of first in first out Weekdays (Mo. - Fr.) from 8:00 - 17:00

Guaranteed response time


< 2 hours 24h support on weekdays

http://www3.ad.siemens.de/partner/

Automation & Drives -Technical Support Your specialists for SIMATIC, SINUMERIK, Drives, ....
More than 70 specialists are handling your inquiries

0180 5050 222 Fax - 223 Basic Support (Free Connect)

0911-895-7777 Fax -7001 Premium Support (Fast Connect)

E-mail: techsupport@ad.siemens.de

Dispatcher
Receives your inquiry and passes it on to the specialists

A&D on the Internet: http://www.ad.siemens.de/support then link to Product Support

Questions about authorization of software products: 0911-895-7200

SIMATIC HMI
Siemens AG 2003. All rights reserved.

Date: File:

04.05.2013 swincc01e.14

SITRAIN Training for


Automation and Drives

Anda mungkin juga menyukai