Anda di halaman 1dari 29

Advances in RAIN WATER HARVESTING

Anand dubey

Reasons of Shortage of Water


Population increase Industrialization Urbanization
(a) Increase in per capita utilization (b) Less peculation area

In places where rain fed/ irrigation based crops are cultivated through ground water Decrease in surface area of Lakes, talab, tanks 1 etc.

Reasons of Shotrage of Water


Continued..

Deforestation
(i) Less precipitation (ii) Absence of Barriers (a) Rain drops checked by leaves of tree (b) Water slowly descends through twigs & trunk Humus acts as reservoir (d) Tiny creatures helps percolation 1 hectare of forest-6-7 Lac ton of water 2 3 (after filtering) top layer can hold 1.2 Lac tons of water

What is the solution ?


Rain water is the ultimate source of fresh water Potential of rain to meet water demand is tremendous Rain water harvesting helps to overcome water scarcity To conserve ground water the aquifers must be recharged with rain water Rain water harvesting is the ultimate answer
3

Why Rain water be harvested


To conserve & augment the storage of ground water To reduce water table depletion To improve the quality of ground water To arrest sea water intrusion in coastal areas To avoid flood & water stagnation in 4 urban areas

What is rain water harvesting ?


It is the activity of direct collection of rain water Rain water can be stored for direct use or can be recharged into the ground water aquifer

The roof catchment are selectively cleaner when compared to the ground level catchment
Losses from roof catchment are minimum Built & Maintained by local communities No Chemical contamination & only required filtration Available at door step with least cost
16

The typical roof top rain water harvesting system comprises


Roof catchment Gutters Down pipe & first flushing pipe Filter Unit Storage Tank

17

Roof catchment
The roof of the house is used as the catchment for collecting rain water. The style construction and material of the roof effect its suitability as a catchment, Roofs made of corrugated iron sheet , asbestos sheet, Tiles or Concrete can be utilized for harvesting the rain water

18

Gutters
Gutters are channels fixed to the edges of roof all around to collect & transport the rainwater from the roof. Gutters can be made in semi-circular and rectangular shape with cement pipe, plain galvanized iron sheet, PVC pipes, bamboos etc. Use of locally available material reduce the overall cost of the system.
19

Down Pipe
It is the pipe which carries the rainwater from the gutters to the filter & storage tank. Down pipe is joined with the gutters at one end & the other end is connected to the filter unit of the storage tank. PVC or GI pipe of 50mm to 75mm (2 to) are commonly used for down pipe. Bamboo can be also used wherever available and possible
20

First Flush Pipe


Debris, dust & dirt collect on the roof during non rainy periods when the first rain arrive. A first flush system arrangement is made to avoid the entering unwanted material into the Filter media & storage tank. This is a simple manually operated arrangement or semi-automatic system with a valve below the T junction
21

Filter Unit
The filter unit is a container or chamber filled with filter media such as coarse sand, charcoal, coconut fiber, pebbles & gravels to remove the debris & dirt from water that enters the tank. The filter unit is placed over the storage tank or separately. It may be of Ferro cement filter unit, Aluminum, Cement rings or Plastic bucket etc.
22

Storage Tank
It is used to store the water that is collected from the roof through filter. For small scale water storage plastic buckets, jerry cans, clay or cement jars, ceramic jars, drums may be used. For larger quantities of water, the system will require a bigger tank with cylindrical or rectangular or square in shape constructed with Ferro cement or cement rings or plain cement concrete or reinforced cement concrete or brick or stone etc. The storage tank is provided with a cover on the top to avoid the contamination of water from external sources. The storage tank is provided with pipe fixtures at appropriate places to draw the water to clean the tank & to dispose of extra water. A provision for keeping the vessel to collect 23 the water is to be made.

Size of Storage Tank


Based on
No. of person in the House hold Per capita water requirement No. of days for which water is required Example Drinking water requirement for a household with 5 family members, period 8 months & 6 lpcd = 5x 180x 6 = 7200 Liters 24

Water available from Roof


Annual rainfall (in mm) x roof area (in sq. m) x coefficient of run off for roof co-efficient of run off GI sheet 0.9 Asbestos 0.8 Tiled 0.75 Plaster on bricks/ Concrete 0.7 Water available from roof top 800mmx 20 sq.m=12800 Liters per annum 25

Water available from Roof


continued

Size of Tank No. of Tanks Volume of Tanks

=1.2 m dia 1.8 m height 4 3.14x1.2x1.2x1.5/4 2.03 cum 2000 liters Volume of of 4 tanks = 4x2000 8000 Liters (this can be designed as per 26requirement)

Cost of Material for Tank


1. Cement 8 bags*Rs. 140.00 2. Grit .25 Cum 3. Sand .4 Cum 4. Perforated Cement rings 5 No. 5. P/fabricated Cement rings 4 No. 6. PVC pipe 63mm dia.*10M 7. P/fabricated Asbestos 10mm dia.*10mm Gutters 8. Mason/ Labor charges. 9. Transportation Total
27

1120.00 200.00 100.00 1000.00 400.00 200.00 250.00 1000.00 130.00 4400.00

Cost of Material for Filtration Tank


1. P/fabricated cement rings 5*Rs. 40.00 2. Cement 2 bags*Rs. 140.00 3. Sand 2 bags 4. Grit 4 bags 5. Charcoal 20 Kg*Rs. 8.00 6. Sand for Plastering 4 bags 7. Mason/ Labor 8. White washing 9. Transportation Total 28 200.00 280.00 50.00 50.00 160.00 100.00 500.00 40.00 50.00 1430.00

Total Cost of construction Rs. 4400.00+ Rs. 1430.00= Rs. 5830.00 The cost on O/ M1. White washing 100.00 2. Water testing 200.00 (2 times a year) 300.00
29

Flooded with Fluoride-G/ water is not potable


Fluoride is an acute toxin with a rating slightly higher then lead. It is infect, one of the most boneseeking elements known to human beings & groundwater in India shows the presence of unhealthy quantities of fluoride. A worrying scenario: daily ingestion of 2 milligram (mg) of fluoride could result in creeping Skeletal fluorosis after 40 years. Excess fluoride causes several diseases like Osteoporosis, Arthritis, Brittle bones, Cancer, Infertility in women, Brain damage,

Alzheimers disease & 30 Thyroid disorders

Flooded with Fluoride-G/ water is not potable


The very nature of fluoride increases this danger manifold. Almost half of each days fluoride intake is retained & is absorbed by the bones & teeth. It was Gerald Cox, of the Mellon Institute in the US, who first found in 1938 that while 1mg/ liter of fluorine in water prevents dental caries over 1.5mg/l causes mottled teeth. The bureau of Indian Standards (BIS) standard for fluoride content is 1-1.5mg/l. It is believed that levels above or below this could cause de4ntal decay. Ironically, there is an increased incidence of dental caries, yellow teeth & twisted limbs among people of all age groups in India. 31

Flooded with Fluoride-G/ water is not potable


A recent publication of the Geographical Survey of India (GSI) names areas that should go on fluoride red alert: Fazilka & Jalalabad in the border district of Ferozpur in Punjab, parts of Gurgaon, Rewari, Mahendranath, Hisar, Fatehabad & Faridabad district in Haryana, Unnao, Rae Barely & Sonebhadra district in Uttar Pradesh, Sidhi district in Madhya Pradesh, Beed district in Maharastra, Nalgonda district in Andhra Pradesh and Dindigul district in Tamilnadu.
32

Fluoride effected Villages


Fluoride effected villages (based on RGNDWM 91) Range 1.5-2 ppm 2-2.5 ppm 2.5-3 ppm 3-4 ppm 4-8 ppm
33

459 No. of villages 159 149 97 40 14

Fluoride effected Villages


continued..

Range of Concentration 1.5-8.4 ppm Lower range of Concentration 1.5-2.5 ppm (about 67% villages) Cause Salt concentration neat aquifers Trend No. of villages increasing Reason (i) Heavy withdrawal of water from upper strata (ii)Less charging of Strata due to Silt/ clayey upper layer of Soil 34

General distribution of Aquifers of Unnao

GL

Surface water (sweet)

Upper system of Aquifers 70 m(+15% variation) Water contains fluoride

Middle system of Aquifers 200 M (+/- 20%) Saline water

Lower system of Aquifers Sweet water

35

How the problem can be minimized


1 By providing pipe water system with source (electric based)
(a) Surface water (b) Deep tubewells

2 Recharging stratas through rainwater harvesting methods


(No. of villages of lower range concentration can be decreased)

3 Storing rain water for drinking purpose


(a) In areas where electricity problem is more (b) In areas where concentration is more In areas where PWS is uneconomical (d) In areas where dependable source is not available 36

For more detail contact

Thank You

37

Anda mungkin juga menyukai