GRID STATION:
It is a station where multiple inputs/outputs comes and goes , where the voltage is transformed as it is required.
transmission
transmission
Power station
Grid station
Grid station
transmission transmission
Lightening arrester Sky wire Rectifier unit Battery room Protection relays ( for T/F: buckles , differential , over current, for line protection: distance , overload , earth fault relay)
Sf6 circuit breaker use sf6 Vacuum circuit breaker use vacuum
To step up or step down the voltage. Transfer power from one A.C voltage to another A.C voltage at the same frequency.
A P.T is used to step down the voltages for measurement, control and protection.
Disconnect any electrical element under no-load condition for safety, isolation and maintenance.
BUSBARS:
A metal strip that is use to interconnections of many electrical elements at a common point ,maintain the specific voltages for transmission and distribution systems.
Bus coupler:
A device that is use to couple two bus bars for requirement.
Sky wires:
A wire that is use to protect the grid station equipments from unwanted high voltage waves and discharge them through earth.
Earth switches:
A wire that is connected to earth. use to isolate the equipments and human beings and protect them from damage.
Protection relays:
Use to protect the all equipments of grid station and transmission and distribution system. Primary protection relays Secondary protection relays
Distance relay
Relay panels
control panels:
use to switching of all transmission and distribution system.
Rectifier unit :
Use to rectify A.C into D.C for protection purposes .
Battery room:
Use to storage D.C and help as back up source for protection system.
11kv section:
Distribution bus bars Feeders Capacitor banks Rectifiers Vacuum circuit breakers Isolator trolleys Meters
Bus bar is used to distribute the electricity . Use to connect different feeders at common point.
Feeders are the out going connections of different areas and industries.
Capacitor banks:
Capacitors are interconnected to each other to improve power factor Secure the system from over loading.
11kv section
Rectifier unit :
11kv section
Isolator trolleys:
Isolator trolley turn out when the line man workers required the conformation that circuit is open.
11kv section
Measurement Meters:
Ampere meters kwh meters
Protection relays:
During fault Relay sense the fault and give signal to V.C.B and V.C.B remove faulty circuit .
11kv section
VAX relays :
Auxiliary Transformer:
This transformer receive the 11kv and step down T/F that provides 400 volts A.C. This is use to supply electricity to all grid station system.
VAX relays :
Rcc
Pdc
DISTRIBUTION OF ELECTRICITY: