Anda di halaman 1dari 72

ZXG10 iBSC Introduction

Contents
General Introduction
Hardware Architecture
Software Architecture
System Principle
System Dimensioning
Summary

SGSN GGSN
NodeB
RNC
NodeB
BTS
BSC
BTS
MSC/VLR GMSC
Inter-PLMN
PSTN
MGW GMGW
Gb


IuPs
IuCs
A




Mc
Nb
Nc
Iur-g
Network Structure
What is the Meaning of i ?
intelligent
intelligent identification of wireless
access intelligent error
self-correction
integration
integrates multi-interfaces
E1/STM-1/IP integrates multi
transmission supported
immensity
large capability
supports 3072 TRX and 15000 Erl
with only two racks
intensify
intensified design
supports FR/EFR/HR/AMR/WB-AMR,
innovative NetSpeed wireless
enhanced technology
IP
All-IP platform
supports IP bearer
All-IP Hardware Platform
According to network developing trend
By means of all-IP platform, iBSC can offer better PS services,
can easily realize IP Abis and IP Gb interface
Separation of User Plane and Control Plane
All-IP hardware is universal for ZXG CN, ZXWN RNC
(WCDMA) and ZXTR RNC (TD-SCDMA)
All-IP Hardware
ZXG
CN
ZXWN
RNC
ZXG
iBSC
Based on V3 Unified Hardware Platform
All-IP Design
User Plane and Control Plane Separation
Modularization
Smooth Evolution
ZXG10 iBSC
Hardware Platform
All-IP
Smooth
Evolution

Module

Two iBSC Platforms
iBSC
All-IP Enhanced iBSC
Advanced Hardware Structure
Modularized Design
Boards
Same boards make up Interface Units with
different software
Different interface units form Resource Unit
AIU/BIU/PCU/TCU exist in logic only, all
interface units are placed in BGSN
RACK1
BCTC
BGSN
BPSN
BGSN
BGSN
BGSN
BGSN
BGSN
RACK2 RACK1
BCTC
BGSN
BPSN
BGSN
Easy Expansion
System expansion by
adding RCBU only
3RCBU/2racks
Flexible Access & Evolution
iBSC Supports Various Access Standards
E1
STM-1
FE/GE
Microwave
Satellite
Evolution
BSC
BSC
RNC
RNC
RNC&BSC
RNC&BSC
RNC&BSC
RNC&BSC
BSC
BSC
BSC
iBSC iBSC iBSC
Benefits
Interface Types of ZXG10 iBSC
No. Logic Interface Connected NE Physical Interface Type
1. A MSC STM-1,E1,FE/GE
2. Gb SGSN E1,FE/GE
3. Abis BTS E1, STM-1, FE/GE
4. Ater iTC STM-1E1

All-IP Enhanced iBSC Interface Indices
A-Interface
E1(T1) A STM-1 A IP A
Abis
Interface
Cabinet
Number of
carriers
Interface
Capability
Number
of
carriers
Interface Capability
Number of
carriers
Interface Capability
E1(T1) Abis
Single
Cabinet
1024
Abis:208 E1(T1)
1024
Abis:208 E1(T1)
1024
Abis:208 E1(T1)
A:188E1(T1) A:4 pairs of STM-1 A:1 pair of GE
Dual
Cabinets
3072
Abis:624 E1(T1)
3072
Abis:624 E1(T1)
3072
Abis:624 E1(T1)
A:700E1(T1) A:11 pairs of STM-1 A:2 pairs of GE
STM_1 Abis
Single
Cabinet
1024
Abis:3 pairs of
STM-1
1024
Abis:3 pairs of STM-1
1024
Abis:3 pairs of STM-1
A:188E1(T1) A:4 pairs of STM-1 A:1 pair of GE
Dual
Cabinets
3072
Abis:9 pairs of
STM-1
1024
Abis:9 pairs of STM-1
3072
Abis:9 pairs of STM-1
A:700E1(T1) A:11 pairs of STM-1 A:2 pairs of GE
IP Abis
Single
Cabinet
1024
Abis:1 pair of GE
1024
Abis:1 pairs of GE
2048
Abis:1 pair of GE
A:252E1(T1) A:4 pairs of STM-1 A:1 pair of GE
Dual
Cabinets

3072
Abis :2 pairs of
GE
3072
Abis:2 pairs of GE
3072
Abis:2 pairs of GE
A:700E1(T1) A:11 pairs of STM-1 A:2 pairs of GE
IPoE Abis
(EIPI+DTB)
Single
Cabinet
1024
Abis:160 E1(T1)
1024
Abis:160 E1(T1)
1024
Abis:160 E1(T1)
A:188E1(T1) A:4 pairs of STM-1 A:1 pair of GE
Dual
Cabinets
3072
Abis:480 E1(T1)
3072
Abis:480 E1(T1)
3072
Abis:480 E1(T1)
A:700E1(T1) A:11 pairs of STM-1 A:2 pairs of GE
IPoE Abis
(EIPI+SDTB
2)
Single
Cabinet
\
\
1024
Abis:3 pairs of STM-1
1024
Abis:3 pairs of STM-1
\ A:4 pairs of STM-1 A:1 pair of GE
Dual
Cabinets
\ \ 3072 11 pairs of STM-1 3072 A:2 pairs of GE
Physical Indices
All-IP Enhanced iBSC Physical Indices
Index ZTE
Dimension (H*D*W) (mm) 2,000 * 800 * 600
Weight
<270Kg(1 rack)
<540Kg(2 rack)
Power Consumption
(All IP Enhance iBSC )
ALL E1:
2,558W/1 rack, 6,368W/2 rack
ALL IP:
2,542W/1 rack,3,808W/2 rack
Power Supply -48VDC (-40VDC ~ -57VDC)
Working Temperature
Long-term:0C~40C.
Short-term: -5C~45C.
Relative Humidity
Long-term: 20%~90%.
Short-term: 5%~95%.
Most Powerful Processing Capability
ZTE Large-Capacity iBSC
All-IP architecture, meet IP evolution trend
Powerful processing capacity
Support E1/T1/STM-1/IP interface, flexible network building
Item Description ZTE
BHCA 4200K
Maximum voice traffic Erl 15000Erl
Maximum throughput of Gb interface 600Mbps
Number of Support TRX 3,072
Contents
General Introduction
Hardware Architecture
Software Architecture
System Principle
System Dimensioning
Summary

iBSC Structure - Shelves
(BPSN)
Switch Shelf
(BGSN)
Resource Shelf
(BCTC)
Control Shelf
(BGSN)
Resource Shelf
Control Shelf (BCTC)
Resource Shelf (BGSN)
Switch Shelf (BPSN)
Board
Name
Full Name Configuration Principle Functions Backup
OMP
Operation and
Maintenance Processing
Board
1 pair per BCTC
Provide global processing and controls
O&M of the whole system (including O&M
agent)
1+1
CMP
Control Main Processing
Board
Depends on the configuration
capacity.
Provide connection with the switching unit
of control plane, implementing all the
protocol processing on control plane
1+1
CHUB Control Plane HUB 1 pair per iBSC
Center where the control flows of BPSN,
BGSN, and BCTC gather
1+1
ICM Integrated Clock Module 1 pair per iBSC Provide system clock 1+1
UIMC
Universal Interface Module
for Control plane
1 pair per BCTC Signaling switching center of the BCTC 1+1
SBCX
X86 Single Board
Computer
2 per iBSC Provide OMM function 1+1
Main BCTC boards layout:
(Global boards include SBCX, OMP, ICM,
CHUB are configured in the main BCTC)
Normal BCTC boards layout:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
R
e
a
r

B
o
a
r
d

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
F
r
o
n
t
B
o
a
r
d
Control Shelf
BCTC
C
M
P
C
M
P
C
M
P
C
M
P
S
B
C
X
S
B
C
X
R
S
V
B
R
S
V
B
U
I
M
C
U
I
M
C
R
U
I
M
2
R
U
I
M
3
O
M
P
O
M
P
R
M
P
B
R
M
P
B
I
C
M
I
C
M
R
C
K
G
1
R
C
K
G
2
R
C
H
B
1
R
C
H
B
2
C
H
U
B
C
H
U
B
iBSC Shelf - BCTC
R
U
I
M
2
R
U
I
M
3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
R
e
a
r

B
o
a
r
d
G
L
I
G
L
I
G
L
I
G
L
I
P
S
N
P
S
N
U
I
M
C
U
I
M
C
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
F
r
o
n
t

B
o
a
r
d
Packet Switching Shelf
BPSN
G
L
I
G
L
I
C
M
P
C
M
P
C
M
P
C
M
P
Board Name Full Name Configuration Principle Functions Backup
PSN
Packet Switching
Network
1 pair per BPSN
Provides data switching among
GLIs
Load
sharing
GLI Gigabit Line Interface
Every 2 pairs GUIM with 1
pair GLI
Provides physical layer adaptation,
IP packet check, fragmentation,
transfer management, and traffic
management
Load
sharing
CMP
Control Main Processing
Board
Depends on the configuration
capacity.
Provide connection with the
switching unit of control plane,
implementing all the protocol
processing on control plane
1+1
UIMC
Universal Interface
Module for Control plane
1 pair per BPSN
Provides signaling switching in
BPSN
1+1
Main BPSN boards layout:
(Global boards include PSN, GLI, CMP
are configured in the main BCTC)
Normal BPSN boards layout:
iBSC Shelf - BPSN
Main BGSN boards layout:
(Global boards include OMP,
GIPI,GUP2, SPB2,DTB,SDTB2 are
configured in the main BGSN)
Normal BGSN boards layout:
R
G
U
M
1
R
D
T
B
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
R
e
a
r

B
o
a
r
d
S
P
B
2
G
U
I
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
F
r
o
n
t

B
o
a
r
d
Gigabit Resource Shelf
BGSN
D
T
B
G
U
I
M
R
G
U
M
2
E
I
P
I
G
U
P
2
R
S
P
B
G
U
P
2
R
S
P
B
R
D
T
B
S
P
B
2
S
P
B
2
R
S
P
B
G
U
P
2
D
T
B
iBSC Shelf - BGSN
iBSC Shelf - BGSN
iBSC Structure Connection Between Shelves
Clock distribution cable and line clock extracting cable
Control plane Ethernet cable
User plane fiber
Monitoring cable
Clock Extracting and Distribution
U
I
M
C
O
M
P
I
C
M
C
H
U
B
Power distribution plug-in box
BGSN
BGSN
BCTC
BPSN
Fan plug-in box
G
U
I
M
G
U
I
M
U
I
M
C
Clock reference
Clock distribution
Control Plane Ethernet Connections
G
U
I
M
U
I
M
C
O
M
P
I
C
M
C
H
U
B
G
U
I
M
U
I
M
C
Power distribution plug-in box
Fan plug-in box
BGSN
BGSN
BCTC
BPSN
Control plane Ethernet interconnection
Realized through CHUB board
CHUB < > UIMC in BCTC through the
backplane printed cable
CHUB < > UIMC in BPSN through Ethernet
cable
CHUB < > GUIM in BGSN through Ethernet
cable
User Plane Connections
G
U
I
M
U
I
M
C
O
M
P
I
C
M
C
H
U
B
G
U
I
M
U
I
M
C
G
L
I
Power distribution plug-in box
Fan plug-in box
BGSN
BGSN
BCTC
BPSN
User Plane interconnection
GLI < > GUIM
Fiber optic cables are used for the connections
between GLI and GUIMs in BGSN

Monitoring Circuit Connections
Sensor
G
U
I
M
U
I
M
C
O
M
P
I
C
M
C
H
U
B
G
U
I
M
U
I
M
C
G
L
I
Cabinet-top fan
Power distribution plug-in box
Fan plug-in box
Fan plug-in box
Fan plug-in box
BGSN
BGSN
BCTC
BPSN
Monitoring of fans
Monitoring of PWRD boards
Monitoring of external environment
Board
Name
Board Function
Name
Functions
GIPI IPBB Implements IP Abis interface access and detaches the user plane
data and the control plane data.
IPI Implements IP A-interface access and detaches the user plane data
and the control plane data.
IPGB Implements IP Gb interface access and detaches the user plane
data and the control plane data.
GUP2 BIPB2 Performs TDM/IP packet conversion and IP packet splitting and
assembling.
AIPB Performs RTP protocol processing
UPPB2 Performs PS-domain user plane protocol processing
DRTB2 Performs transcoding and rate adaptation
SPB2 LAPD2 Performs LAPD signaling processing
SPB2 Performs SS7 signaling processing
GIPB2 Implements E1 Gb interface access and FR protocol processing
iBSC Board Name & Board Function Name
Shelf Configuration Example (1)
G
U
I
M
G
U
I
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
S
P
B
G
U
P
D
T
B
D
T
B
2 2
D
T
B
G
U
P
D
T
B
D
T
B
2
G
U
P
S
P
B
2 2
D
T
B
D
T
B
G
U
I
M
G
U
I
M
D
T
B
S
P
B
G
U
P
2 2
R
S
P
B
G
U
P
2
G
U
I
G
U
I
D
T
B
D
T
B
M M
D
T
B
D
T
B
S
P
B
D
T
B
2
G
U
P
2
S
P
B
2
R
D
T
R
D
T
B
B
R
D
T
R
D
T
B B
R
D
T
R
D
T
B B
R
D
T
B
R
S
P
B
R
S
P
B
R
D
T
B
R
D
T
B
R
S
P
B
R
D
T
R
D
T
B B
R
D
T
R
D
T
B B
R
S
P
R
S
P
B B
R
S
P
B
D
T
B
S
P
B
2
S
P
B
2
S
P
B
2
G
U
P
G
U
P
2 2
D
T
B
D
T
B
G
U
P
2
D
T
B
D
T
B
G
U
P
2
D
T
B
D
T
B
G
U
P
G
U
P
2 2
D
T
B
S
P
B
2
D
T
B
D
T
B
G
U
I
M
G
U
I
M
D
T
B
G
U
P
G
U
P
2 2
D
T
B
D
T
B
G
U
P
2
D
T
B
D
T
B
G
U
P
2
D
T
B
D
T
B
G
U
P
G
U
P
2 2
R
D
T
R
S
P
B B
R
D
T
B
R
D
T
B
R
D
T
B
R
D
T
R
D
T
B B
R
D
T
B
R
D
T
B
R
D
T
B
R
D
T
B
R
D
T
B
R
D
T
B
R
D
T
B
R
D
T
R
D
T
B B
R
D
T
B
R
D
T
B
R
S
P
B
G
U
I
M
G
U
I
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
G
L
I
G
L
I
G
L
I
G
L
I
FAN
FAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
R
U
I
M
2
R
U
I
M
3
S
P
B
G
U
P
D
T
B
D
T
B
2 2
D
T
B
G
U
P
D
T
B
D
T
B
2
S
P
B
D
T
B
D
T
B 2
G
U
P
S
P
B
S
P
B
2 2 2
G
I
P
I
/
S
P
B
2
G
I
P
I
/
C
M
P
C
M
P
C
M
P
C
M
P
U
I
M
C
S
B
C
X
S
B
C
X
U
I
M
C
C
H
U
C
H
U
O
M
P
O
M
P
B B
I
C
I
C
M M
S
P
B
G
U
P
2 2
R
S
P
G
U
P
B 2
G
U
P
2
G
U
I
G
U
I
D
T
B
D
T
B
M M
D
T
B
D
T
B
G
U
P
D
T
B
2
D
T
B
D
T
B
G
U
P
G
U
P
2 2
S
P
B
2
G
L
I
G
L
I
P
S
N
P
S
N
C
M
P
C
M
P
U
I
M
U
I
M
C C
R
U
I
M
2
R
U
I
M
3
R
S
V
R
D
T
B
B
R
D
T
R
D
T
B B
R
D
T
R
D
T
B B
R
D
T
B
R
D
T
R
D
T
B B
R
S
P
B
R
S
V
B
R
M
P
R
M
P
B B
R
C
K
G
1
R
C
K
G
2
R
C
H
B
1
R
C
H
B
2
R
S
P
B
R
D
T
R
D
T
B B
R
D
T
R
D
T
B B
R
S
P
B
R
G
E
R
/
R
S
P
B
R
G
E
R
/
R
D
T
R
D
T
B B
R
S
P
R
S
P
B B
BIU
AIU
PCU
TCU
R
G
U
M
R
G
U
M
1 2
R
G
U
M
R
G
U
M
1 2
R
G
U
M
R
G
U
M
1 2
R
G
U
M
R
G
U
M
1 2
R
G
U
M
R
G
U
M
1 2
R
G
U
M
R
G
U
M
1 2
Abis Interface E1
A-Interface E1
Abis Interface IP
A-Interface IP
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
R
G
E
R
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
R
G
U
M
R
G
U
M
R
U
I
M
2
R
U
I
M
3
R
G
E
R
R
U
I
M
2
R
U
I
M
3
R
S
V
B
R
G
E
R
1 2
R
S
V
B
R
M
P
R
M
P
B B
R
C
K
G
1
R
C
K
G
2
R
C
H
B
1
R
C
H
B
2
R
G
E
R
R
G
U
M
R
G
U
M
1 2
R
M
I
R
M
I
N N
R
G
E
R
R
G
U
M
R
G
U
M
1 2
R
G
E
R
R
G
E
R
R
G
E
R
R
G
E
R
G
U
I
M
G
U
I
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
G
U
I
M
G
U
I
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
G
L
I
G
L
I
G
L
I
G
L
I
FAN
FAN
G
I
P
G
I
P
I I
G
U
P
2
G
U
P
G
U
P
2 2
C
M
P
C
M
P
C
M
P
C
M
P
U
I
M
C
S
B
C
X
S
B
C
X
U
I
M
C
C
H
U
C
H
U
O
M
P
O
M
P
B B
I
C
M
G
I
P
G
I
P
I I
G
U
P
2
G
I
P
I
G
U
I
G
U
I
M M
G
U
P
2
G
U
P
G
U
P
2 2
P
S
N
P
S
N
C
M
P
C
M
P
U
I
M
U
I
M
C C
BIU
AIU
PCU
TCU
G
U
P
G
U
P
2 2
G
U
P
2
G
U
P
2
G
I
P
G
I
P
I I
G
I
P
I
G
U
P
2
G
I
P
G
I
P
I I
G
U
P
2
G
I
P
G
I
P
I I
G
U
P
2
G
U
P
2
G
U
P
2
G
U
P
2
G
U
P
2
C C
R
G
E
R
I
C
M
Shelf Configuration Example (2)
Shelf Configuration Example (3)
G
U
I
M
G
U
I
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
G
U
P
S
P
B
2 2
G
U
I
M
G
U
I
M
S
P
B
2
G
U
P
2
R
D
T
B
R
D
T
R
D
T
B B
R
D
T
B
R
S
P
B
R
D
T
R
D
T
B B
R
D
T
B
R
S
P
B
S
P
B
2
S
P
B
2
G
U
P
2
S
P
B
2
R
S
P
R
S
P
B B
R
D
T
B
R
S
P
B
G
U
I
M
G
U
I
M
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
G
L
I
G
L
I
G
L
I
G
L
I
FAN
FAN
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
PWRD
FAN
FAN
FAN
R
U
I
M
2
R
U
I
M
3
E
I
P
I
D
T
B
D
T
B
D
T
B
D
T
B
D
T
B
S
P
B
2
S
P
B
G
U
P
G
U
P
2 2 2
G
I
P
I
/
S
P
B
2
G
I
P
I
/
C
M
P
C
M
P
C
M
P
C
M
P
U
I
M
C
S
B
C
X
S
B
C
X
U
I
M
C
C
H
U
C
H
U
O
M
P
O
M
P
B B
I
C
M
R
G
E
R
G
U
I
G
U
I
M M
G
L
I
G
L
I
P
S
N
P
S
N
C
M
P
C
M
P
U
I
M
U
I
M
C C
R
U
I
M
2
R
U
I
M
3
R
S
V
R
D
T
B
B
R
S
V
B
R
M
P
R
M
P
B B
R
C
K
G
1
R
C
K
G
2
R
C
H
B
1
R
C
H
B
2
R
D
T
R
D
T
B B
R
D
T
R
D
T
B B
R
S
P
B
R
G
E
R
/
R
S
P
B
R
G
E
R
/
R
S
P
B
BIU
AIU
PCU
TCU
R
G
U
M
R
G
U
M
1 2
R
G
U
M
R
G
U
M
1 2
R
G
U
M
R
G
U
M
1 2
R
G
U
M
R
G
U
M
1 2
R
G
E
R
G
I
P
I
G
I
P
I
G
I
P
I
G
I
P
I
G
U
P
2
G
U
P
2
G
U
P
2
G
U
P
2
G
U
P
2
G
U
P
2
G
U
P
2
G
I
P
I
G
I
P
I
R
G
E
R
R
G
E
R
R
G
E
R
R
G
E
R
E
I
P
I
G
U
P
2
G
U
P
2
E
I
P
I
D
T
B
D
T
B
D
T
B
D
T
B
D
T
B
E
I
P
I
G
U
P
2
E
I
P
I
D
T
B
D
T
B
D
T
B
D
T
B
D
T
B
E
I
P
I
G
U
P
2
G
U
P
2
G
U
P
2
R
D
T
B
R
D
T
B
G
U
P
2
I
C
M
Abis Interface IPoE
A-Interface IP
Contents
General Introduction
Hardware Architecture
Software Architecture
System Principle
System Dimensioning
Summary

Foreground Software
HARDWARE
BSP & Drivers
OSS
B
R
S
P
P
VxWorks
S
C
S
D
B
S
O
M
S
S
S
R
A
N
C
R
A
N
S
S
R
A
N
U
M
C
R
BSP & Drivers OSS
BRS
SCS
OMS
RANC
RANSS
PP
DBS
SS
RANU
MCS
Foreground Software
Contents
General Introduction
Hardware Architecture
Software Architecture
System Principle
System Dimensioning
Summary

iBSC Structure - Logic Unit
Power, Fan
Processing unit
O&M unit
Peripheral device
monitoring unit
A
c
c
e
s
s

u
n
i
t
S
w
i
t
c
h
i
n
g

U
n
i
t
ZXG10 iBSC
BTS
MSC
SGSN
TC unit
User plane
Processing unit
O&M Unit

OMP Board
SBCX


OMP
OMP
H
U
B
-R

100M Ethernet
SVB SBCX

OMP
OMP
H
U
B
OMCR

S
w
i
t
c
h
i
n
g

U
n
i
t

100M Ethernet
SBCX
O&M Unit
Processing Unit & Peripheral Device Monitoring Unit
CMP board
PS/CS service and call control management
BSSAP, BSSGP and system resource management
PWRD and ALB
PWRD collects the information of peripheral equipment and
environment, including status of power distributor and fan,
temperature, humidity, fog, water, and infrared, etc.
ALB for alarm based on different alarm grades
Processing Unit - CMP
Peripheral Device Monitoring Unit - PMU
Access Unit - Abis Interface Unit (BIU)
E1/ T1
HW
1
2
32

BIU
LAPD
E1 Abis
T
User plane
switching
network
Control plane switching network
Internal
Ethernet
To TCU or UPU
To CMP
D
T
B
U
I
M
U
G
U
P
S
P
B
Access Unit - Abis Interface Unit (BIU)

BIU
UPU
TCU
HW
IP Abis
User plane
switching
network
Control plane switching network
Internal
Ethernet
External
Ethernet
SCTP
UDP
To CMP
IPBB BIPB2
G
I
P
I
G
U
P
2
G
U
P
2
G
U
P
2
Access Unit - Abis Interface Unit (BIU)
BIU
UPU
TCU
HW
Internal
Ethernet
SCTP
IP
To CMP
(GE)
1
2
32
E1/ T1
IPoE Abis
PPP
HDLC
UDP
UDP
User plane
switching
network
Control plane switching network
BIPB2
D
T
B
E
I
P
I
ML/MC-PPP
RTP
c UDP
RTP
c UDP
G
U
P
2
G
U
P
2
G
U
P
2
(FE)
Access Unit A-Interface Unit (AIU)
E1/ T1 HW
1
2
32
TCU
MTP2
1
2
16
AIU
STM-1
UIM
T

User plane
switching
network
Control plane switching network
Internal
Ethernet
T network on
local layer UIM
E1 A
D
T
B
S
P
B
G
U
P
Access Unit A-Interface Unit (AIU)
AIU
AIPB
HW
Internal
Ethernet (GE)
External
Ethernet
SCTP
To CMP
BIPB2
UDP
Control plane switching network
User plane
switching
network
IP A
IPI
G
I
P
I
G
U
P
2
RTP
UDP
RTP
UDP
G
U
P
2
(FE)
Access Unit - Gb Interface Unit (GIU)
E1/ T1
1
2
16
UPPB
1
2
16
GIU
User plane
E1 GB
To CMP
UDP
network
switching
Control plane switching network
S
P
B
S
P
B
G
U
P
Internal
Ethernet
Access Unit - Gb Interface Unit (GIU)
Control plane switching network
GIU
UPPB2
HW
Internal
Ethernet
External
Ethernet(GE)
UDP
To CMP
UDP
BIPB2
UDP
IP Gb
User plane
switching
network
IPGB
G
I
P
I
G
U
P
2
G
U
P
2
User plane Processing Unit UPU
Transcoder Unit TCU
UPU & TCU

2*GE
FE
1
st
Switch Subsystem 2
nd
Switch Subsystem

FE
BUSN 1 BUSN N
Switch Control
2
nd
Switch Subsystem 2
nd
Switch Subsystem

IP Switch Unit (PSU)
User Plane Data Flow in CS Domain
BIU
User plane
switch network
AIU
A Interface
GIU
CMP OMP
UPU TCU
1
2
Control plane
switch network
Gb Interface
Abis Interface
Flow: 1->2
User Plane Data Flow in CS Domain - Shelves
BGSN
GUIM
BCTC BPSN
GUIM
PSN
GLI
DTB/
GIPI/
STDB2
CHUB
UIMC
OMP
SPB/
EIPI
SPB GUP2
SPB
GIPI
GLI
UIMC
User Plane Control Plane
Abis
TS Switch
ICM
GPS
A
GUP2 GUP2
CMP
SBCX
DTB/
SDTB2/
GIPI
SGSN1
Gb
MSC 1
User Plane Data Flow in CS Domain - Boards
BPSN
BGSN
BGSN
IPBB GUIM BIPB2 GUIM GLI PSN
GUIM GLI IPI GUIM AIPB
Abis
A
AIU
BIU
User Plane Data Flow in PS Domain
BIU
User plane
Switching network
AIU
GIU
1
CMP OMP
UPU TCU
2
Control plane
Switching network
A Interface
Gb Interface
Abis Interface
Flow: 1->2
BIU detaches data
Send to UPU for processing
Send to GIU
User Plane Data Flow in PS Domain - Shelves
BGSN
GUIM
BCTC BPSN
GUIM
PSN
GLI
DTB/
GIPI/
STDB2
CHUB
UIMC
OMP
SPB/
EIPI
SPB GUP2
SPB
GIPI
GLI
UIMC
User Plane Control Plane
Abis
TS Switch
ICM
GPS
A
GUP2 GUP2
CMP
SBCX
DTB/
SDTB2/
GIPI
SGSN1
Gb
MSC 1
Abis
BPSN
BGSN
BGSN
IPBB GUIM BIPB2 GUIM GLI PSN
GUIM GLI IPGB GUIM UPPB2
Gb
BIU
PCU
User Plane Data Flow in PS Domain - Boards
Control Plane Signal Flow in CS Domain
BIU
AIU
GIU 1
2
CMP OMP
3
UPU TCU
User plane
Switching network
A Interface
Gb Interface
Abis Interface
Control plane
Switching network
Flow: 1->1 Flow: 1->2
Flow: 2->3->3->2 Flow: 2->2
Control Plane Signal Flow in CS Domain - Shelves
BGSN
GUIM
BCTC BPSN
GUIM
PSN
GLI
DTB/
GIPI/
STDB2
CHUB
UIMC
OMP
SPB/
EIPI
SPB GUP2
SPB
GIPI
GLI
UIMC
User Plane Control Plane
Abis
TS Switch
ICM
GPS
A
GUP2 GUP2
CMP
SBCX
DTB/
SDTB2/
GIPI
SGSN1
Gb
MSC 1
BCTC
BGSN
BGSN
IPBB GUIM CHUB UIMC
IPI GUIM
Abis
A
CMP
CHUB UIMC
AIU
BIU
OMP
Control Plane Signal Flow in CS Domain - Boards
Control Plane Signal Flow in PS Domain
BIU
AIU
GIU 1
4
CMP OMP
6
UPU TCU
2
3
5
A Interface
Gb Interface
Abis Interface
User plane
Switching network
Control plane
Switching network
Flow: 1->1 Flow: 1->2
Flow: 2->3->3->2 Flow: 5->3->2
Control Plane Signal Flow in PS Domain - Shelves
BGSN
GUIM
BCTC BPSN
GUIM
PSN
GLI
DTB/
GIPI/
STDB2
CHUB
UIMC
OMP
SPB/
EIPI
SPB GUP2
SPB
GIPI
GLI
UIMC
User Plane Control Plane
Abis
TS Switch
ICM
GPS
A
GUP2 GUP2
CMP
SBCX
DTB/
SDTB2/
GIPI
SGSN1
Gb
MSC 1
Flow: 1->1
Control Plane Signal Flow in PS Domain - Shelves
BGSN
GUIM
BCTC BPSN
GUIM
PSN
GLI
DTB/
GIPI/
STDB2
CHUB
UIMC
OMP
SPB/
EIPI
SPB GUP2
SPB
GIPI
GLI
UIMC
User Plane Control Plane
Abis
TS Switch
ICM
GPS
A
GUP2 GUP2
CMP
SBCX
DTB/
SDTB2/
GIPI
SGSN1
Gb
MSC 1
Flow: 5->3->2
Control Plane Signal Flow in PS Domain - Boards
BIU
Abis
BCTC BGSN
IPBB GUIM CHUB UIMC CMP
Flow: 1->1
BCTC BGSN
IPGB GUIM CHUB UIMC
BIU
PCU
CMP
Gb
CHUB UIMC UPPB GUIM GUIM
GUIM IPBB BIPB
Abis
Control Plane Signal Flow in PS Domain - Boards
Flow: 5->3->2
Contents
General Introduction
Hardware Architecture
Software Architecture
System Principle
System Dimensioning
Summary

RCBU Configuration - BIU Unit
DTB board: NDTB =NAbis NSPB28/32

GUP2 board: NVTCD = NTRX /392

SPB2 board: NSPB2 = NLAPD /512


TDM mode
GIPI board: NGIPI = Ceiling(NTRX / 2385)

GUP2 board: NGUP2 = Ceiling(NTRX / 840)
IP over Ethernet mode
RCBU Configuration - BIU Unit
DTB board: NDTB = NAbis /32

EIPI board: NEIPI = Ceiling ( NDTB /2 )

GUP2 board: NGUP2 = Ceiling( NTRX / 840)


IP over E1 mode
RCBU Configuration - TC and AIU Unit
DTB board: NDTB =(NA NSPB16)/32

SPB2 board: 2 pieces

GUP2 board: NTCD=NA-trunk/ (100 * 15)
TDM mode
GIPI board: NGIPI = Ceiling(NTRX / 2385)

GUP2 board: NGUP2 = Ceiling(NTRX / 840)

IP over Ethernet mode
RCBU Configuration - PCU Unit
SPB board: NSPB=NGb/32M

GUP2 board: NGUP2 = NGb / (400 * 16K * 15)

TDM mode
GIPI board: NGIPI = NGb/600M

GUP2 board: NGUP2 = NGb / 100M
IP over Ethernet mode
CLKG: 2 pieces , 1+1 backup, Mandatory
BCTC (Control Shelf) Configuration
OMP: 2 pieces, 1+1 backup, Mandatory
CHUB: 2 pieces , 1+1 backup, Mandatory
UIMC: 2 pieces , 1+1 backup, Mandatory
SBCX : 2 pieces( 1 piece is also allowed)
CMP: NCMP =Ceiling (NTRX/(512*2))
UIMC: 2 pieces, 1+1 backup, Mandatory
BPSN (Packet Switch Shelf) Configuration
PSN: 2 pieces, 1+1 backup, Mandatory
CMP: it can support 1024 TRX,1+1 backup
GLI: NGLI=Ceiling (NResource-Shelf/2,1)
Capacity Calculation (Maximum Traffic)
Full configuration (two racks)
6 CMP (1+1) 2 CPU / CMP 700k BHCA / CPU
700k*2*3= 4200k BHCA
Traffic Model
BHCA/Sub 1.1
SMS-MO+MT/Sub 1.7
LOC Upgrading/Sub 1.2
HO internal/external/Sub 0.9
Mean calling time 60s
Maximum Erlang
4200K*0.22*60/3600= 15400 Erlang
Rate of BHCA
1.1/(1.1+1.7+1.2+0.99)=0.22
Control Shelf
(BCTC)
6 CMP
Type BTS CELL TRX CS
Traffic
TCH
(FR)
PS Traffic
(Mbps)
Capacity 343 1033 3072 8770 22272 46.25
Capacity Calculation (Example)
1 CMP process 1024 TRX
Ceiling(3072/1024)=3 CMP
1+1 Backup
Abis Resource
(BIU Unit )
1 GIPI process 2385 TRX
Ceiling(3072/2385)=2 GIPI
4 GIPI
1+1 Backup
1 GUP2 process 840 TRX
Ceiling(3072/840)=4 GUP2
BGSN Shelf
IP over Ethernet mode
8 GUP2
1+1 Backup
Capacity Calculation (Example)
A Interface Resource
(TC and AIU Unit )
1 GIPI process 7500 ERL
Ceiling(8770/7500)=2 GIPI
4 GIPI
1+1 Backup
1 GUP2 process 6090 TCH
Ceiling(22272/6090)=4 GUP2
BGSN Shelf IP over Ethernet mode
1+1 Backup
8 GUP2
Capacity Calculation (Example)
Gb Interface Resource
(PCU Unit)
1 GIPI process 600 Mbps
Ceiling(46.25/600)=1 GIPI
2 GIPI
1+1 Backup
1 GUP2 process 100 Mbps
2 GUP2
BGSN Shelf
Ceiling(46.25/100)=1 GUP2
1+1 Backup
IP over Ethernet mode
Capacity Calculation (Example)
4 GLI
Packet Switching Shelf
(BPSN)
1 GLI process 2 resource shelf
Ceiling(4/2)=2 GLI
1+1 Backup
4 GIPI,8 GUP2 need
4 resource shelf
Capacity Calculation (Example)
Contents
General Introduction
Hardware Architecture
Software Architecture
System Principle
System Dimensioning
Summary
Summary
Largest Capacity
15000Erl
4200K
3072TRX
All - IP
Shelf
BCTC
BPSN
BGSN:BIU,AIU,GIU,UPU,TCU
Data and signal flow

Anda mungkin juga menyukai