Overview

iManager M2000 Mobile Element Management System


(EMS M2000) is the centralized management platform
for Huawei mobile network.
iManager M2000 includes client and server.
This presentation will be focus on the newest version of
M2000
(R009)
in
Fault,
Performance,
and
Configuration sides.

Chapter 1 Introduction With M2000


R009
Chapter 2 M2000 Basic Feature
Chapter 3 M2000 Troubleshooting

Network Position of iManager


M2000

Physical Structure and Software


Architecture M2000

Chapter 1 Introduction With M2000

Chapter 2 M2000 Basic Feature

Chapter 3 M2000 Troubleshooting

M2000 BASIC FEATURES

Topology
Management

Performance

Management

Fault Management

Security

Configuration
Management

Management

Topology Management

Create Physical NE

Managing Topology
Data

Monitoring NEs

Modifying Network
Topology Views

Setting Up a Physical
Topology View

Alarm List and Alarm Log Concepts

Current Alarm: including


uncleared and unacknowledged,
uncleared and acknowledged,
cleared and unacknowledged.

History Alarm

Current
Alarm

new

new

Alarm log

Alarm List

History Alarm: providing long term


alarm store and query; including
cleared and acknowledged alarms

Alarm List: Alarm managers mainly


focus on the Alarm list, the alarms are
summed up.

Alarm Log: providing alarm query, on


all the alarms collected, which works
as the sum of current alarm and
history alarms;

(Alarm List)

Contd

Procedure of Performance Huawei M2000 System


NE (Network
Element)
mrf.zip

file

PM Service (Provides the function of equipment result data storage and


analyze management)
Sybase (Ex ample, Use Sybase Central)

PMExport (Export Data from database to file, provides the function of file interface)
pmexport_2010xxxx files

PM Service

M2000 Client

Chapter 1 Introduction With M2000

Chapter 2 M2000 Basic Feature

Chapter 3 M2000 Troubleshooting

Performance
Management
Incomplete Data
1. Synchronization

2. Retrieve

Add User Defined Counters Management


1. Create user Defined

2. Create Template

Performance
Management
3. Create Task Performance Data Export

Alarm Management
Warning should be Critical ?

Alarm Management
Alarm Redefinition

The tab name is


changed from
Severity Redefine
to Redefine

Three columns are


added: Type,
Redefined Name,
Redefined
Severity,
Redefined Type.

Alarm Redefinition
Firstly click Add to open the
dialog window.

Original Setting
panel displays the
alarm settings
before redefinition.
Redefined Setting
panel offers the Name,
Type and Severity for
redefinition.
Remember to
Enable the
redefinition rule.

SMS 507 Problem


Invalide Alarm Names ?

SMS 507 Problem


Adding AlarmID to script

Example : List alarmID in script put in input.txt as input item in script updateAlarm.sh

AlarmID=2402,
AlarmID=2404,
AlarmID=2406,
AlarmID=2408,
AlarmID=2410,
AlarmID=2412,
AlarmID=2414,
AlarmID=2416,
AlarmID=2418,
AlarmID=2420,
AlarmID=6438,
AlarmID=6440,
AlarmID=6442,
AlarmID=6444,
AlarmID=6446,
AlarmID=6448,
AlarmID=6450,
AlarmID=6452,
AlarmID=6454,
AlarmID=6456,

AlarmName="DC Fan Alarm"


AlarmName="Rectifier DC Low or High Voltage"
AlarmName="Rectifier module fault alarm"
AlarmName="Medium surge protections failure MSPF"
AlarmName="AC L1 failure alarm PLN"
AlarmName="AC L2 failure alarm PLN"
AlarmName="AC L3 failure alarm PLN"
AlarmName="Fence break or Grounding cut or Air condition removed"
AlarmName="Genset run alarm"
AlarmName="Genset failure alarm"
AlarmName="DC Fan Alarm"
AlarmName="Rectifier DC Low or High Voltage"
AlarmName="Rectifier module fault alarm"
AlarmName="Medium surge protections failure MSPF"
AlarmName="AC L1 failure alarm PLN"
AlarmName="AC L2 failure alarm PLN"
AlarmName="AC L3 failure alarm PLN"
AlarmName="Fence break or Grounding cut or Air condition removed"
AlarmName="Genset run alarm"
AlarmName="Genset failure alarm"