OAU004301 UMG8900 Data

Configuration and Routine


maintenance R003
ISSUE 2.0

Fixed Network Curriculum


Development Section

Introduction
Before

configuring the data, you should first have

some knowledge about the networking and user


requirements, and collect the basic information
required by data configuration.
The

configuration should follow the basic sequence

and configuration requirement.


This

course mainly introduces the basic procedures,

configuration method, basic configuration principles,


and hardware and interface configuration.

Confidential

Objectives
Upon

completion of this course, you will be able

to:
Know

basic procedures, method,


and principles of configuration;

Master

UMG8900
Configuration;

Master

Data

UMG8900
Routine
Operation and Maintenance.

Confidential

References

U-SYS UMG8900 Data Configuration Manual

Data Configuration

U-SYS

UMG8900

Universal

Operation Manual

Routine Operation and maintenance

Confidential

Media

Gateway

Course Contents

Data Configuration
Routine operation
Routine maintenance

Confidential

Procedure of Data Configuration

Confidential

Configuration Overview
The

data configuration of UMG8900 is mainly completed

through the MML command.

LMT client software mainly completes the configuration management


and maintenance of system.

Before

performing data configuration, firstly collect the

detailed networking information .

Confidential

Data Collection
MGW Side Related Parameter

MGC Side Related Parameter

IP address and
route over the
interface

Consider the whole network to plan

IP address and
route

Consider the whole


network to plan

MGW ID

Plan in advance

MGC ID

Plan in advance

Transmission
protocol type

Keep consistent with MGC

Transmission
protocol type

Keep consistent with


MGW

Authentication
Mode

Consistent with MGC

Authentication
Mode

Consistent with MGW

SCTP protocol
initialization
parameter

When the transmission protocol


type is SCTP, configure SCTO
initialization parameter
according to actual condition

SCTP protocol
initialization
parameter

Consistent with MGW

Call processing
metrics

Distribution rate between PPU and


CMU. Plan in advance.

Media resource
processing
metrics

Distribution rate between CMU and


VPU. Plan in advance.

Confidential

Logical board and Physical board

Logical

Board:

It means the boards are classified and named based on the functions.
Board type is corresponding to the logical board.

Physical

Board:

It finally reflects the distinction in software/hardware configuration of


board.

Hardware type is corresponding to the physical board.

For Example :OMU is loglic Board name;FOMU is Physical Board name.

Confidential

Hardware Configuration Procedure

Confidential

Introduction to Frame

Confidential

Frame Configuration Command

Add a central switch frame:

ADD FRM: FN=1, FT=CONTROL;

Confidential

Principle for Board Configuration


In

the main control frame, the FOMU, FNET and FCLK

boards have been added by default.

FOMU is inserted in the front slot 7 and slot 8 in the main


control frame (plug-in frame 1), FCLK is in the back slot 0 and 1
(plug-in frame 1). FOMU/FMPU and FNET must be inserted
front and back opposite each other.

Front-inserted

boards : FOMU, FMPU, FFLU, FCMF, FVPU,

FSPF and FHRU.


Back-inserted

and FNET.

Confidential

boards : FTNU, TCLU, FCLK, FBLU, FCMB

Principle for Board Configuration


All

the interface boards can be inserted in any back slots except

slot 6, 7, 8 and 9 (Only FCLK can be inserted in the back slot 0


and 1 of main control frame):

FG1O, FE8T, FP4L, A4LM/A/B/C, FA4L, E32 and S2L/A/B/C.

Some

boards have strict front-back opposite plug-in requirement.

The boards with front-back plug-in requirement include:

FFLU (front) and FBLU (back),

FHRU (front) and FG1O and E1GM/A/B/C, FA4L, FBAP, FBFE, FBGE, FE8T
(Back),

FMPU/FOMU (front) and FNET (back).

Confidential

Configure cascading between 2 frame


Configure

cascading between the main control frame and the central switch

frame:

ADD FRMLNK: TP=TNU, LKBN=0;

Configure

the cascading between the service frame and the central switch

frame:

ADD FRMLNK: TP=BLU, BN=0, LKBN=1;

Confidential

SSM: Synchronous Status Message


SSM,

namely the synchronous status message, and is also

called synchronous quality information.


SSM

is used to reflect the level of synchronous timing signal

directly in synchronous timing transmission link.

For the line clock source, SSM is extracted by the line interface
board and reported to FOMU, and then FOMU configures the
SSM of line clock source to clock module.

If the external synchronous reference source of clock module is


2048kbit/s signal, the clock module can extract SSM from signal.

For GPS reference source, FOMU does not set the SSM level
and its level is PRC constantly.

Confidential

Reference Source Selection


Reference Source Selection

Manual mode?

N
SSM participates in control?

N
Based on priority
In sequence:
GPS, Line1, Line2, Ext
End

Confidential

Specify the master


reference source and
handover is not performed

Y
According to the SSM level

Clock Configuration Command

Designate line clock as the clock source and grade 2 as the clock
grade:
MOD CLK: MODE=MANUAL, GRADE=TWO, SRC=LINE1;
Configure clock to extract clock from the port 0 on the E32 0:
SET LINECLK: LINE=LINE1, BT=E32, BN=0, PN=0;

Confidential

Two-Frame Cascading

Confidential

Board Configuration Command


Add boards to the main control frame:
ADD BRD: FN=1, SN=1, BP=FRONT, BT=VPU, HBT=FVPB,
BS=LOADSHARE, BN=1, ADS=ACTIVE;
ADD BRD: FN=1, SN=6, BP=BACK, BT=TCLU, HBT=TCLU,
BS=ONEBACKUP, BN=0;

Confidential

Configuration Procedure
MGW
configuration
Interface configuration is

completed?

Is it necessary to modify
SCTP parameter?

N
Interface IP configuration, route

configuration and firewall configuration

SCTP initialization parameter


modification

(optional)

Add MGC

Set package forwarding (optional)


N

Signalling link configuration

Set MGW label


Call process distribution rate configuration:
PPU:CMU
Is it necessary to modify
H.248 parameter?
Y

N
Media resource process distribution rate:
CMU:TCU

H.248 protocol parameter configuration


Activate MGW device

End

Confidential

Relationship between MGW tables

Confidential

Configure IP interface

Configure the IP address of the OMU 0:

ADD

IPADDR:

BT=OMU,

BN=0,

IFT=ETH,

IFN=0,

IPADDR="10.1.1.1", MASK="255.255.255.0";
Configure

ADD

the route from the OMU 0 to the SoftX3000:

ROUTE:

BT=OMU,

DSTMASK="255.255.255.0",
NEXTHOP="10.1.1.254";

Confidential

BN=0,

DSTIP="192.168.0.1",
RTTYPE=NEXTHOP,

MGW Control Data Configuration

Configure VMGW

SET

VMGW:

VMGWID=0,

MIDTYPE=IP,

MID="10.1.1.1:5555",

IPNUM=50000, TDMNUM=30000;

Configure the master MGC ID

ADD

MGC:

VMGWID=0,

MGCIDX=0,

MIDTYPE=IP,

MID="192.168.0.1:2944", MSS=MASTER;

Configure H.248 protocol :

SET H248PARA: VMGWID=0, CT=BINARY, TT=UDP;

Configure an H.248 signaling link

ADD

H248LNK:

BN=0,

PEERIP="192.168.0.1",

LINKID=0,

VMGWID=0,

PEERPORT=2944,

LOCALIP="10.1.1.1",

LOCALPORT=5555, LINKNAME="To-Master MGC";

Activate the VMGW:

Confidential

ACT VMGW: VMGWID=0;

MGCIDX=0,

SG Configuration Procedure

Confidential

Configure SS7 LINK


Configure M2UA link set and links to the SoftX3000:

ADD L2UALKS: PROTYPE=M2UA, LKS=0;

Configure M2UA links from the SPF 0 to the master SoftX3000:

ADD L2UALNK: PROTYPE=M2UA, BN=0, LNKNO=0, LKS=0,


LOCALPN=6666,

LOCALIP1="10.1.1.3",

REMOTEPN=2904,

REMOTEIP1="192.168.0.1", PRIO=0;

Configure MTP2 links to the PSTN switch

ADD

MTP2LNK:

LNKTYPE=M2UA64K,

LNKNO=0,
IFBT=E32,

LKS=0,
IFBN=0,

BINIFID=1,
E1T1N=1,

STRTTS=16, SPFBN=0, SUBBN=0, BITREVERSE=OFF;

Confidential

TDM Bearer Configuration Process


UMG8900

only needs to accomplish the configuration of various

types of circuits.

Confidential

IP Bearer Configuration Procedure


IP Bearer Configuration
Interface IP address
configuration of HRB
Route (Optional)
& gateway configuration

Set VPU bearer relationship

End

Confidential

IP Bearer Configuration
Configure

ADD

TDM connections to the PSTN switch.

TDMIU:

BN=0,

BT=S2L,

TIDFV=0,

TIDLV=4095,

VMGWID=0;
ADD TDMIU: BN=3, BT=S2L, TIDFV=12288, TIDLV=16383,
RT=INSIDE, VMGWID=0;
Configure

gateway address:

ADD GWADDR: BT=HRB, BN=0, IPADDR="10.10.1.254",


MASK="255.255.255.0";
Configure

bearer relation:

ADD BEARREL: BN=0, IP="10.10.1.1";

Confidential

RSP Configuration Procedure


RSP Configuration
Configure RSP
Frames and Boards
Add Asynchronous Tone

Configure TDM Resource

Configure E1 on RSP Board

End

Confidential

Configure RSP

Add UAM frames

ADD UAFRM: FN=1, PN=0, RN=0, RFN=1, FT=RSP10, FM=MAIN,


BN=0, VMGWNO=0;

Add boards to the master frame:

ADD UABRD: FN=1, SN=3, BT=ASL;

Configure asynchronous tones:

ADD ATONE: BT=VPU, BN=0, TONEID=RINGTONE;

Configure RSP E1 connections

ADD

UACFG:

FN=1,

SN=9(RSP),

E1SRC=E32,

SBN=0, BN0=2, PN0=0, BN1=2, PN1=1;

Confidential

BN=0(SPF),

Debug RSP Configuration


1.

Check if the physical ports are connected via the command DSP
E1PORT.

2.

Check the board status of E32, TNU, SPF and OMU.

3.

Check if the time slot of asynchronous tone is configured via the


command LST ATONE.

4.

Check if the time slot type of RSP frame is correctly configured via
the command LST TDMIU.

5.

Check if E1 of RSP is correctly configured via the command LST


RSPCFG.

6.

Check if the clock board status is normal.

7.

Check if the semi-permanent connection status to RSP board is


normal via the command LST TDMSPC.

Confidential

Course Contents

Data Configuration
Routine Operation
Routine Maintenance

Confidential

Local Maintenance Terminal System


LMT system:

Confidential

Local Maintenance Terminal System


UMG8900

Operation Online Help:

It is used for viewing help information of systems.


UMG8900

Operation and Maintenance System:

It is used for data configuration, device operation and maintenance


and right setting, and so on.
UMG8900

Alarm Management System:

It is used for alarm query and process.


UMG8900

Performance Management System:

It is used for creating performance measure task and displaying


results.
UMG8900

Trace Viewer:

It is used for viewing the traced messages during off line.

Confidential

Operation and Maintenance System

There are two modes to start the operation and maintenance system:
Run

[Start/programs/Huawei

terminal/UMG8900

UMG8900

V100R003/UMG8900

local

maintenance

Operation

and

Maintenance System].

On

the alarm management system interface, select [System/Open

Operation and Maintenance System], or click

Confidential

on the tool bar.

Main interface of operation and maintenance system

(1)
(2)

(3)

1.Main interface of operation and maintenance system

(4)

(6)

(1) Menu bar

(2) Tool bar

(3) Navigator window

(4) Information
output window

(5) Status bar a

(6) Status bar b

Confidential

(5)

Alarm Management System


(1)
(2)

(3)

(1) Menu bar


(4) Status bar

Confidential

(2) Tool bar

(3) Navigator
window

(4)

Performance Management System

(1)
(2)

(5)

(3)

(4)

(6)

(1) Menu bar

(2) Tool bar

(3) Navigator
window

(4) Information
output window

(5) Task information


window

(5) Status bar

Confidential

Trace Viewer

(1)
(2)

(3)

(1) Menu bar

Confidential

(2) Tool bar

(3) Navigator
window

Login Infomation
User

name/User description: admin

Password/Confirm

password: 9061mgw

site

ip:omu board ip (for example:190.1.30.1);

site

name:random define (for example:Local Host);

Confidential

System Management Routine command


Command

Function

LST FILE

List the related information of various types of data files at OMU.

BCK FILE

Dump the specified file manually to the server set by MOD MFTP.

ADD

Add an FTP user. The user information includes user name,

FTPUSR

password, working directory and authority.

SET

Open/Close FTP server and set timeout for server at the same time.

FTPSRV
CPY

Copy the source files to the destination directory.

CRE

Create a routine test task for the specified device on the BAM.

RTSTTSK

Confidential

Service Management Routine Command


Command

Function

DSP IPIF

Query the status of the link layer protocol on an interface and the statistics
information of sending/receiving packets.

DSP E1PORT

Query the status of the E1/T1 interface.


Query the statuses of TDM timeslots so as to learn about which

DSP TDMSTAT

timeslots are occupied and which timeslots are idle in the current E1/T1
interface.

LST TDMIU

Query the configuration of timeslots on various TDM interface boards.

DSP SCTPCON

Query the SCTP connection information.

DSP L2UALKS

DSP L2UALNK

Query the status of the M2UA, IUA, V5UA link group.The status of the
normal link group is ACTIVE.
DSP L2UALNKQuery the status of the M2UA, IUA, V5UA link.The status
of the normal link is ACTIVE.

Confidential

Service Management Routine Command

Command
DSP H248LNK

Function
Query the connection status of the H.248 signaling link.The status of the
normal link is UP.

DSP VMGW

Query the status of the VMGW and the selected MGC.

ACT/DEA VMGW

Activate/Deactivate the VMGW.

DSP CLK

Query the status of the board clock.

LST UATID

LST UAPOS

Query the corresponding TID value on the port based on the location
information of the user port.
Query the location information of the user port based on the TID value on
the port.

Confidential

Course Contents

Data Configuration
Routine operation
Routine maintenance

Confidential

Maintenance Overview
Basic tasks and main maintenance contents are described as follows.
1.Make sure that the devices operate normally, and that their electric
performance, mechanical performance, technical indices and various
service indices conform to the standards.
2.Perform network optimization, so as to ensure that the coverage area can
obtain high communication quality.
3.Fast and exactly remove various communication faults to ensure smooth
communications.
4.Perform the cooperation between entire networks in the whole running
process to ensure a reliable internet operation.
5.Make sure that new devices and capacity-expansion devices are correctly
connected to the networks.

Confidential

Common Methods

I.

Comparison method

II.

Substitution method

III.

Minimum system method

IV.

Protocol tracing analysis method

Confidential

Basic Requirements for Maintenance Personnel

I.

Special qualification and skills

II.

Familiarity with the system and networking

III.

Operation

IV.

Instrument and meters

Confidential

Equipment Room Maintenance

I.

Sudden maintenance

II.

Routine maintenance

III.

Periodic maintenance

Confidential

Maintenance Table and Operation Guide

I.

Routine keep-watch maintenance table

II.

Maintenance task plan

III.

Itinerant checking maintenance

IV.

Designated maintenance

Confidential

Network Management

1. Performance statistics
indices as running data, interface flow, resource utilization and data flow.

2. Network optimization
I.

System investigation

II.

Data analysis

III. Optimization scheme drawing and implementation

Confidential

Routine Maintenance Operation Guide

Routine

maintenance mainly involves equipment room, device

running status, functional subsystems, service bearer and


media resources, signaling and description of routine
maintenance items.
Routine Maintenance Type:
Daily

Routine Maintenance

Monthly
Yearly

(Quarterly) Maintenance

Maintenance

Confidential

Daily Routine Maintenance Items

Maintenance items

Operation

Air conditioner

Check the cooling degree, switch, etc. of the air conditioner.

Power supply

Check if the power supply has open circuit.

transmission

Check if interruption, error codes, etc. happening to the


transmission system.

Tools, meters and


documents

The tools, meters and maintenance documents shall be complete


and intact; otherwise additional explanation shall be given.

On-duty personnel
tasks

Sum up the jobs on duty, including the description and the


handling of the faults discovered on this duty and the left faults of
the last duty.

Troubles remained

Describe the faults that have not been completely fixed yet,
including the fixing status and the fault severity.

Monitor check

The chief operator checks the on-duty jobs to make sure that jobs
are smoothly handed over, faults are fixed and the equipment
room is normally running.

Confidential

Monthly (Quarterly) Maintenance Operation


Guide

1. Termination System
2. System
3. Cabinet
4. Power Supply
5. Grounding wire
6. Spare Parts

Confidential

Yearly Maintenance Operation Guide


1.Functional Subsystem
Referenced standards
Maintenance items
The correctness of statistics
reports

Check if the statistics system is correct by means of comparison.

2.Connection
Referenced standards
Maintenance items
Trunk connection

Trunk connections are reliable, trunks are complete and intact, and labels are
easily recognizable.

Network cable
connection

Network cable connections are reliable, network cables are complete and intact,
the hub is intact and labels are clear and explicit.

Optical path
connection

The optical paths between racks are reliable, optical fibers are complete and
intact, without being crushed to be flat or folded; labels are clear and explicit.

Connection cables
between racks

The connection cables between racks are reliable, various cables are complete and
intact, and labels are easily recognizable.

Confidential

Confidential