COURSE OBJECTIVE
To learn
What
DIFFERENT UTILITIES
Following are different utilities
required in processing plants:
Plant
Control Valve
Shutdown Valve
Blowdown Valve
Instrument Air
Compressors
Instrument
Air Dryers
Dry
instrument
air to -40 C
dew point.
One (01) on
absorption
and Other
on
Regeneratio
n.
Instrument Air
Receiver
Normally size for
20 min retention
time.
Used in control
valve, shutdown
valve, blowdown
valve, etc.
Requirement Calculation-I
Plant air requirement is random, hence not
calculated.
For Instrument Air, different methods are used and
common in industries.
Method-1:
1.35 SCFM for each panel mounted small case
controller
0.65 SCFM for each field transmitter, controller,
and manual loading station
1.00 SCFM for each valve positioner or
transducer using under 40 psig air
2.00 SCFM for each valve positioner or
transducer using over 40 psig air
Requirement Calculation-II
Method-1I:
70%
Requirement CalculationIII
Method-1II:
Most common method:
Control
NITROGEN GENERATION
SYSTEM
Why is it required?
Mainly used for
Purging
of equipments / piping
Blanketing of vessels / tanks
for safe operation.
Purity required is 99.9% pure.
Maximum oxygen allowable is 200
ppm.
Overview of
Nitrogen Generation System
Pre-Treatment
Pre-Filter Coalescer
Filter
After
N2 Membrane
Nitrogen Receiver
Normally size
for 20 min
retention time.
Used for
purging and
blanketing for
safe
operation.
Requirement Calculation-I
Purging is of commonly two (02) types.
Displacement Purging:
The
Where:
(scf)
Vo = Water volume of pipeline (cf)
P = Absolute pressure of nitrogen in the
pipeline during purging (psia)
Requirement Calculation-II
Pressurization Purging:
Determined
V = 1.2nVoP/Pa
Where: V = Total nitrogen volume required (scf)
Vo =
Blanketing (In-Breathing /
Out-Breathing)
In-breathing and out-breathing
calculations are carried out by API.
Depends on vessel pumping in / out
flow rates.
In pumping out nitrgen in-breath to
avoid vaccum and during pumping
in nitrogen out-breath to avoid over
pressure.
Blanketing (In-Breathing /
Out-Breathing)
Vessel
Main System
in Heaters/Furnaces
Power Generation
Compressor Engines
Fuel gas was also used for blanketing
purpose but now avoided because of
safety concerns.
Overview of
Fuel Gas System
Fuel Gas
System
Efficiency (~ 80%)
Burner Efficiency (~60%)
Turbine Efficiency (~ 55 65%)
Engine Efficiency (~ 40 %)
Above are typical efficiencies,
vendor provided actual efficiencies
based on their design.
Requirement Calculation
Calculation of fuel gas requirement
is just applying efficiencies.
First requirement is calculated
from formula below:
Fuel flow = Heating duty / Heating
value
Typical heating value of fuel gas
(natural gas) is 970 Btu/scf.
Types Of Treatment
Filtered Water
Multimedia Filters (30 Micron)
Contains three layers of media
consisting of
Anthracite
coal
Sand
Garnet
Gravel
(non-filtering) for
supporting
Types Of Treatment
Maintenance
Normal pressure (clean): 3-7 psi
Maintenance: 10 psi (above clean)
A backwash is performed by
reversing the flow of water.
The ideal backwash rate is 12-15
gpm/sq ft.
Types Of Treatment
Activated Charcoal Filters
For Color, Taste and Odor
Most activated carbons are made
from raw materials such as
nutshells, wood and coal.
Not regenerated by backwash but
removes any fines or suspended
matter.
Types Of Treatment
Cartridge Filters
Final filter element before Reverse
Osmosis.
Remove upto 0.5 micron
to 5 micron.
Types Of Treatment
Reverse
Osmosis
Passing high
pressure
water
through a
semi
permeable
membrane.
Types Of Treatment
Demin Water
Completely free (or almost) of dissolved
minerals by De-ionization Process.
Also called Hungry Water.
Deionizers (DI) remove both cations
and anions, releasing hydrogen ions
(H+) in exchange for the former, and
hydroxyl ions (OH-).
Deionizers categorized as "mixed bed",
containing both cation and anion resin
in a single vessel.
Types Of Treatment
Drinking Water
It requires UltraViolet (UV) treatment
after RO for bacteria (microorganism) removal.
Water Requirement
Typical requirement for calculation is
considered as 50 gallon per person
per day.
Typical gardening water requirement
is 3 gallon per ft2 per day.
STORAGE TANKS
Cone Roof Tanks Most Common
for atmospheric storage.
STORAGE TANKS
Floating Roof Tanks For Low
flash point fluids like naphtha,
gasoline, etc.
STORAGE TANKS
Dome Roof Tanks- For higher
pressure than atmospheric i.e.
pyrolysis gasoline, reformate, etc.
Condensate Flowmeters
Orifice Flow Meter
TheTurnDown Ratefor orifice plates
are less than 5:1. Their accuracy are
poor at low flow rates.
Turbine Flow Meter
The turndown ratios may be more
than 100:1 if the turbine meter is
calibrated for a single fluid and used
at constant conditions. Accuracy
may be better than +/-0.1%.
Gas Flowmeter
Senior Orifice Flow Meter
Themost commonly use flow
meter.
Called senior orifice because
orifice can be changed online.