Anda di halaman 1dari 21

Function

Common Daily Utility

Preparing the first use, you need to do...

Submit ESN to Huawei teams,


to get the FMA license then
go to License update

Create New Project

How to take FMA data input

MML Part

Output from MML


part(CFGMML), we can see
the sub rack and know the
DPU slot idle at RNC

MML Compare -1

MML Compare - 2

The red one is the different


parameter
The blue color means one file have
this parameter, but another file
doesnt have

Alarm

FMA also can show the


alarm, we can filter
occurred alarm at Loc
Info

Operation Log

It show operation
log/activity log when
input the file (COL
LOG) from RNC MML, we
can found all activity
at RNC related with
Operation command,
result execution,
user/operator, etc.

Investigate by PCHR - 1

In Best Cell ID, right click and


select filter by column then input
Cell ID that you want to investigate

Investigate by PCHR - 2

From interface fault reason, there is


UL CE congestion occurred at the cell.
In this case we select cell ID 29973

From PCHR also can show the EcNo, RSCP


and RTWP measurement

KPI Performance - 1
KPI tendency
chart

We need find out why the KPI


decreased. First step, Top Cell

The KPI
value

From here, we can know the


CSSR KPI decreased. Its very
clear

KPI Performance 1a

We can make graph


individually base on KPI as
shown on statistic
measurement by double click
the KPI selected

Display KPI info related


formula measurement, Class
name by right click the KPI
selected

KPI Performance - 2

3
Next step we need to
find out the root cause

We can see that 51.12% RRC fail is


from Top Cells

KPI Performance - 3

Add the counter


which you want to
query, select the
counter then OK

KPI Performance - 4

Input the Cell ID here

KPI Performance - 5

Mostly the problem


come from UL CE
Congest for cell ID
29971, 29972 and 29973

Performance Cluster KPI Monitor -1

Select Cluster button then right click


> add cluster > Input cell ID

Performance Cluster KPI Monitor -2

After compile cell ID


to be one cluster
measurement, then go
to Investigate

Detail value

FMA Dashboard KPI Performance, Alarm and


Operation log

For this case, regarding CS


accessibility degradation at RNC
Purwokerto inline with SCTP Link
Fault alarm occurred

As shown on above picture for FMA dashboard, we can check


the performance degradation layering with alarm occurred
and log activity at the same time