Anda di halaman 1dari 7

Heat Exchanger Spesification

Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-100
Type
Shell and Tube
Operation Data
Data
Shell Side
Tube Side
Fluid Stream
42
5
Fluid Flow (kg/h)

1325

443

Temperature in (C)

30

657

Temperature out (C)

123

242

Operating pressure (kPa)


3500
3500
No. of passes
1
2
Fouling factor (m2 C/W)
0.00009
0.00009
Heat Duty (kW)
143
LMTD (C)
279
Overall U (W/m2 C)
229
Design Specification
Type of unit
Fixed tube
Material
Heat Transfer Area (m2)
Tube OD (mm)
Tube Length (m)
Shell ID (m)
Tube Pitch (mm)
Tube Thickness (mm)
Number of tubes
Tube
Prelimenary Design
of arrangement
Acetic Acid Plant

from Methanol

SS-316 atau SA-240


2.237
19.050
4.880
0.540
24
0.710
120
Triangular

Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-101
Type
Shell and Tube
Operation Data
Data
Fluid Stream
Fluid Flow (kg/h)

Shell Side
43
1325
0
123
243
3500
1
0.00009

Temperature in (C)
Temperature out (C)
Operating pressure (kPa)
No. of passes
Fouling factor (m2 C/W)
Heat Duty (kW)
LMTD (C)
Overall U (W/m2 C)
Design Specification
Type of unit
Material
Heat Transfer Area (m2)
Tube OD (mm)
Tube Length (m)
Shell ID (m)
Tube Pitch (mm)
Tube Thickness (mm)
Number of tubes
Tube arrangement

University of Indonesia

Tube Side
6
1328
0
657
242
3500
2
0.00009
429
189
618

Fixed tube

SS-316 atau SA-240


3.661
19.050
4.880
0.540
24
0.710
180
Triangular
1

Heat Exchanger Spesification


Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-108
Type
Shell and Tube
Operation Data
Data
Shell Side Tube Side
Fluid Stream
36
3
Fluid Flow (kg/h)
1838
1771
0
0
Temperature in (C)
117
700
Temperature out (C)
117
657
Operating pressure (kPa)
100
3500
No. of passes
1
2
Fouling factor (m2 C/W)
0.00009
0.00009
Heat Duty (kW)
62
LMTD (C)
550
Overall U (W/m2 C)
1615
Design Specification
Type of unit
Fixed tube
Material
Heat Transfer Area (m2)
Tube OD (mm)
Tube Length (m)
Shell ID (m)
Tube Pitch (mm)
Tube Thickness (mm)
Number of tubes
Tube arrangement

Prelimenary Design of Acetic Acid Plant


from Methanol

SS-316 atau SA-240


0.070
19.050
4.880
0.540
24
0.710
110
Triangular

Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-108
Type
Shell and Tube
Operation Data
Data
Fluid Stream
Fluid Flow (kg/h)

Shell Side
36
1838
0
117
117
100
1
0.00009

Temperature in (C)
Temperature out (C)
Operating pressure (kPa)
No. of passes
Fouling factor (m2 C/W)
Heat Duty (kW)
LMTD (C)
Overall U (W/m2 C)
Design Specification
Type of unit
Material
Heat Transfer Area (m2)
Tube OD (mm)
Tube Length (m)
Shell ID (m)
Tube Pitch (mm)
Tube Thickness (mm)
Number of tubes
Tube arrangement

University of Indonesia

Tube Side
3
1771
0
700
657
3500
2
0.00009

62
550
1615
Fixed tube

SS-316 atau SA-240


0.070
19.050
4.880
0.540
24
0.710
110
Triangular
2

Heat Exchanger Spesification


Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-104
Type
Plate and Frame
Operation Data
LMTD (oC)
Foulingfactor (m2
o
C/W)

38,43
0.769

1150.585
Overall U (w/m2 oC)
Design Specification
Plate Area (m2)

0.25

Plate Length (m)

0.316

Plate Width (m)

0.791

Plate Spacing (m)


Plate thickness (m)

0.0015
0.0008

Amount of Plate

Prelimenary Design of Acetic Acid Plant


from Methanol

Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-106
Type
Plate and Frame
Operation Data

Equipment Specification
Heat
Equipment Name
Exchanger
Equipment Code
E-107
Plate and
Type
Frame
Operation Data

LMTD (oC)

39.65

Foulingfactor (m2 oC/W)

0.994

LMTD (oC)

183.09

Overall U (w/m2 oC)

335.568

Foulingfactor (m2 oC/W)

0.999

Design Specification
Plate Area (m2)
0.03
Plate Length (m)
Plate Width (m)
Plate Spacing (m)
Plate thickness (m)
Amount of Plate

0.122
0.245
0.0015
0.0008
2

University of Indonesia

Overall U (w/m2 oC)


227.744
Design Specification
Plate Area (m2)
Plate Length (m)
Plate Width (m)
Plate Spacing (m)
Plate thickness (m)
Amount of Plate

0.75
0.548
1.369
0.0015
0.0008
2

Heat Exchanger Spesification


Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-103
Type
Plate and Frame
Operation Data
LMTD (oC)
Foulingfactor (m2
o
C/W)

75.15
0.970

Overall U (w/m2 oC)


1397.480
Design Specification
Plate Area (m2)
Plate Length (m)
Plate Width (m)
Plate Spacing (m)
Plate thickness (m)
Amount of Plate

0.05
0.141
0.354
0.0015
0.0008
3

Prelimenary Design of Acetic Acid Plant


from Methanol

Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-110
Type
Plate and Frame
Operation Data
LMTD (oC)
17.43
2
Foulingfactor (m
0.941
o
C/W)
Overall U (w/m2 oC)
111.615
Design Specification
Plate Area (m2)
0.75
Plate Length (m)
Plate Width (m)
Plate Spacing (m)
Plate thickness (m)
Amount of Plate

0.548
1.369
0.003
0.0008
3

University of Indonesia

Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-111
Type
Plate and Frame
Operation Data
LMTD (oC)
31.90
Foulingfactor (m2 oC/W)

0.782

Overall U (w/m2 oC)


1163.441
Design Specification
Plate Area (m2)
0.2
Plate Length (m)
0.283
Plate Width (m)
0.707
Plate Spacing (m)
0.0015
Plate thickness (m)
0.0008
Amount of Plate
5

Heat Exchanger Spesification


Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-110
Type
Plate and Frame
Operation Data
LMTD (oC)
17.43
Foulingfactor (m2
0.941
o
C/W)
Overall U (w/m2 oC)
111.615
Design Specification
Plate Area (m2)
0.75
Plate Length (m)
Plate Width (m)
Plate Spacing (m)
Plate thickness (m)
Amount of Plate

0.548
1.369
0.003
0.0008
3

Prelimenary Design of Acetic Acid Plant


from Methanol

Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-111
Type
Plate and Frame
Operation Data
LMTD (oC)

31.90

Foulingfactor (m2 oC/W)

0.782

Overall U (w/m2 oC)


1163.441
Design Specification
Plate Area (m2)
0.2
Plate Length (m)
Plate Width (m)
Plate Spacing (m)
Plate thickness (m)
Amount of Plate

0.283
0.707
0.0015
0.0008
5

University of Indonesia

Equipment Specification
Equipment Name
Heat Exchanger
Equipment Code
E-112
Type
Plate and Frame
Operation Data
LMTD (oC)
13.28
2
Foulingfactor (m
0.753
o
C/W)
Overall U (w/m2 oC)
1293.287
Design Specification
Plate Area (m2)
0.2
Plate Length (m)
Plate Width (m)
Plate Spacing (m)
Plate thickness (m)
Amount of Plate

0.283
0.707
0.0015
0.0008
7

Control valve spesification


Instrument Code
PIC 100
TIC 100
TIC 101
TIC 102
PIC 102
LiC 100
TIC 103
TIC 104
TIC105
TIC 106
TIC 107

Prelimenary Design of Acetic Acid Plant


from Methanol

Value size
8
10
8
10
8
10
8
4
2
8
0.75

Instrument Code
PIC 104
LIC 101
TIC 108
PIC 105
LIC 102
FIC 100
PIC 106
PIC 107
LIC 103
LIC 104
TIC 109

University of Indonesia

Value size
0.75
0.75
0.75
0.75
0.75
10
8
3
0.75
0.75
0.75

PNID Acetic acid plant

Prelimenary Design of Acetic Acid Plant


from Methanol

University of Indonesia

Anda mungkin juga menyukai