Anda di halaman 1dari 20

Technical Training Program

Centuris

Overview of the Centuris bed*


Indikator posisi sudut kepala
control untuk perawat

Longitudinal tilt indicator

Tempat control ranjang


pasien

Penahan sisi
samping kaki/ atau
badan
Penahan kaki

Head siderail

Storage power cable,


head or foot end

Board depan
Tambahan matras

Handle darurat CPR

knob tambahan

Tiang pembantu
Intravenous (infus)
Corner bumpers

Pedal pengatur laju


ban

Roda, 12.5 cm

Matras Pasien
Tempat tas drainase

Untuk menurunkan Tempat indicator


kaki

Pemegang tabung oksigen

Untuk menurunkan Tempat Indikator


kepala

*: Pendant not shown on this bed version

Operation of the Centuris bed


Built-In-Controls (BIC: embedded controls) on Split Siderails

External control
panel

Patient functions
Internal control
panel

Caregiver functions

Pengoperasian matras centuris

Kontur Automatis:
A raise command is sent to the thigh section motor 5 seconds after the head section starts
to rise. The same principle applies to lowering.
Therefore, adjusting the head section by short movements, does not change the position
of the thigh section or the position of the patient.
This function is performed by the microprocessor in the power supply unit.

Trendelenburg/Reverse Trendelenburg: (Untuk org dengan tekanan darah


rendah)
Whatever the initial height the Hilow actuators are activated in opposite directions to obtain Maximum 12in both Trend and Rev Trend
positions.
Trendelenburg

Rev-Trendelenburg

Backup battery:
all electrical functions are operational when the bed is fitted with a backup properly charged battery.
The system goes into a sleep mode if no function is activated for more than 2 minutes approx.

Operation of the Centuris bed


Brake and steer:
-

The diagrams below show the positions of the brake bar and pedal (option)
and the individual caster.

Stop

Free

Steering

Brake release
Brake activation
5

Mechanical Subsystem of the Centuris bed


Brake and Steer System:

Is activated individually on each caster or by the pedal


(option).

Brakemechanism

Fixationscrew

Brakecrossbar

Operation of the Centuris bed


CPR function:
-

The CPR handles are located on either side of the head section of the bed.
Pulling one of these handles disengages the head actuator gearing, allowing
the head section to descend.

Mechanical Subsystem of the Centuris bed


CPR function:
The two handles on either side operate a cable
connected to the adjustable head section
release system
No dampers are necessary
Release mechanism on Head section motor

Release handle

Release mechanism
8

Operation of the Centuris bed


Siderails:
The siderails:
- have two positions: raised and lowered.
- click into the raised position.
- can be released in one-step
- are dampened so no need to support the rail when lowering

Description of the parts of the bed


Battery location
(Not shown on this picture)

Foot Hilow motor

Adjustable thigh section motor

Adjustable head section motor

Power supply unit

Lockout unit (Depends on the configuration)

Head Hilow motor

Wiring diagram of the bed with BIC


Battery
Backrest
Hilow head
Power supply
unit
Knee

Hilow foot

T cable

Left Siderail

Right Siderail

Wiring diagram of the bed with Pendant


Battery
Backrest

Hilow head
Power supply
unit
Knee

Hilow foot

Pendant

Lockout unit

Power supply unit (PSU):

Positioned under the central part of the sleep surface

Power supply unit:

The Power supply unit is a Linak , model CB06S


OBMe unit that is controlled by a microprocessor.

A Command plug

A Motor plug

Power supply unit:

Led included:

Power Supply Unit mencakup


Status LED daya yang dapat
memiliki warna yang berbeda
dalam operasi normal
Power pada: hijau

Motor diaktifkan: red

Fungsi lain diaktifkan: orangePower


on: green

Motor aktif : red

Fungsi lain functions activated:


orange

15

Motors:

The motors are 24V DC from the Linak

LA27 series

THANK YOU

CPR : usaha untuk mengembalikan fungsi


pernafasan dan fungsi sirkulasi serta penanganan
akibat terhentinya fungsi atau denyut jantung pada
orang-orang yang mengalami kegagalan total tibatiba.
CPR dapat menjaga darah beroksigen yang mengalir
ke otak dan organ vital lainnya sampai penanganan
medis lebih lanjut dapat mengembalikan irama
jantung normal.Ketika jantung berhenti , kurangnya
oksigen darah dapat menyebabkan kerusakan otak
hanya dalam beberapa menit. Seseorang mungkin
meninggal dalam waktu delapan sampai 10 menit .

Lengthfully retracted

220 cm

Lengthfully extended

230 cm

Sleep deck length

196 cm

Minimum widthwith siderails


raised

100 cm

Maximum widthwith siderail


stored

105.5 cm

Sleep deck width

86.4 cm

Minimum underbed clearance

13.5 cm

Caster size

12.5 cm

Sleep deck height range

46.5 cm to 76.5 cm

Maximum Trendelenburg
/Reverse Trendelenburg

+12/-12

Safe working load

204 kg

Trendelenburg
DefinisiPosisitrendelenburgadalah posisi berbaring
pada tempat yang datar di mana kepala berada lebih
rendah daripada pelvis. Ini adalah posisi standar untuk
pembedahan abdominal atau ginekologi.
Pada posisi ini pasien berbaring di tempat tidur dengan
bagian kepala lebih rendah daripada bagian kaki.Posisi
ini dilakukan untuk melancarkan peredaran darah ke
otak.
Indikasi :
1) Pasien dengan pembedahan pada daerah perut
2) Pasien shock
3) Pasien hipotensi.

Anda mungkin juga menyukai