Robert K. Giba
Thursday, February 9, 2006
2005 Daikin AC
This Presentation Is Intended To:
Provide a broad overview of the current generation
iTouch Controller.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 2 REV
2005 Daikin AC
A (02/2006)
This Presentation Is Not Intended To:
Train the audience on the nuances of programming the
iTouch Controller to fit a particular end-user profile.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 3 REV
2005 Daikin AC
A (02/2006)
iTouch Controller Specifications
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 4 REV
2005 Daikin AC
A (02/2006)
Feature Set Current iTC
Monitoring and VRV, HRV, SkyAir, RA, General (Ventilation mode and volume can be
control purpose ADP controlled for HRV)
D3Dio
D3Di
Schedule setting
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 5 REV
2005 Daikin AC
A (02/2006)
PHONE
LINE
D3 NET
PLUS
ADAPTOR
ETHERNET
PCMCIA Card
Slot
Off INTERNAL
BATTERY
On ON/OFF
RESET
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 7 REV
2005 Daikin AC
A (02/2006)
Connectivity Detail
Public line / ISP
Unified remote adapter
* Unified ON/Off
[DCS302A72] * Status monitoring
AIRNET Internal * etc
Modem
Onboard D3-NET
Ethernet
port
Pi port Dio unit Control the drain
pump, lighting and
other eq.
Remote Optional software
Remote
monitoring/control
monitoring/control required.
Di unit: Monitoring of room
Simple interlock function enter/exit sign
Simple interlock function
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 8 REV
2005 Daikin AC
A (02/2006)
iTouch Controller Commissioning
Master Setup Pre-Commissioning Sheet
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 10 REV
2005 Daikin AC
A (02/2006)
iTouch Controller Commissioning
Group / Zone Setup Pre-Commissioning Sheet
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 11 REV
2005 Daikin AC
A (02/2006)
Primary D3-NET Capacity Considerations
iTouch Controllers F1/F2 connection will support:
Up to 64 addressed indoor units and equipment (groups)
Not more than 10 outdoor units
Manifolded outdoor units count as only 1 outdoor unit
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 12 REV
2005 Daikin AC
A (02/2006)
Primary D3-NET Capacity Considerations
Up to 128 zones possible with (1) iTouch Controller
Groups may be programmed to reside in more than one zone
Simply programming a zone replicates the settings for all
the units in that zone
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 13 REV
2005 Daikin AC
A (02/2006)
Primary D3-NET Capacity Considerations
An individual unit or master with unaddressed slave units
defines a GROUP
No more than 64 GROUPS may be included in a ZONE.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 14 REV
2005 Daikin AC
A (02/2006)
Primary D3-NET Capacity Considerations
60 Indoor Units X
Acceptable
X
15 Outdoor Units
Not Acceptable X
X
X
F1/F2
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 15 REV
2005 Daikin AC
A (02/2006)
The Views Icon View
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 16 REV
2005 Daikin AC
A (02/2006)
The Views Icon Details View (Zone List Display)
Cooling
Mode
Room
Temperature
Latest software
revision allows for
the selection of
Celsius or
Fahrenheit
temperature
display
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 17 REV
2005 Daikin AC
A (02/2006)
The Views List View (Displayed by Zones)
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 18 REV
2005 Daikin AC
A (02/2006)
The Views Icon View (Showing Individual Groups)
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 19 REV
2005 Daikin AC
A (02/2006)
The Views Icon Details View
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 20 REV
2005 Daikin AC
A (02/2006)
The Views List View (Showing Individual Groups)
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 21 REV
2005 Daikin AC
A (02/2006)
Start All / Stop All
Collectively start and stop all units with a single selection
Includes all equipment in all zones and all groups
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 22 REV
2005 Daikin AC
A (02/2006)
Starting and Stopping Equipment by Zone
Collectively start and stop all units within a single zone
Includes all equipment in the zone selected
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 23 REV
2005 Daikin AC
A (02/2006)
The GROUP Properties Page
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 24 REV
2005 Daikin AC
A (02/2006)
The GROUP Properties Page
1:1-00
1: Indicates that this unit
exists on the primary or on-
board D3-NET connection of
the iTouch Controller.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 25 REV
2005 Daikin AC
A (02/2006)
The icon LEGEND
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 26 REV
2005 Daikin AC
A (02/2006)
The icon LEGEND
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 27 REV
2005 Daikin AC
A (02/2006)
Navigating the iTouch
Modifying Group Settings
2005 Daikin AC
View and Modify Primary Group Settings
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 29 REV
2005 Daikin AC
A (02/2006)
View and Modify Primary Group Settings
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 30 REV
2005 Daikin AC
A (02/2006)
View and Modify Primary Group Settings
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 31 REV
2005 Daikin AC
A (02/2006)
View and Modify Primary Group Settings
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 32 REV
2005 Daikin AC
A (02/2006)
View and Modify Primary Group Settings
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 33 REV
2005 Daikin AC
A (02/2006)
View and Modify Primary Group Settings
2. Select OK.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 34 REV
2005 Daikin AC
A (02/2006)
View and Modify Primary Group Settings
Advanced Operation
settings allow the
user to further
customize the group
device.
1. Tap the Advanced
Operation button.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 35 REV
2005 Daikin AC
A (02/2006)
View and Modify Primary Group Settings
Advanced Operation
allows the
administrator to place
restrictions on the
functionality of the
remote controller.
Additionally, fan
speed and fan
direction (where
applicable) can be
adjusted.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 36 REV
2005 Daikin AC
A (02/2006)
Digital Input (Di) and Digital Input / Output (Dio) Group Devices
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 37 REV
2005 Daikin AC
A (02/2006)
Access Controller Settings
Customizing the iTouch Controller
2005 Daikin AC
Accessing the SETTING mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 39 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 40 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 41 REV
2005 Daikin AC
A (02/2006)
Setting the time in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 42 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 43 REV
2005 Daikin AC
A (02/2006)
Set up password protection in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 44 REV
2005 Daikin AC
A (02/2006)
Set up password protection in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 45 REV
2005 Daikin AC
A (02/2006)
Set up password protection in the iTouch Controller
Press to lock
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 46 REV
2005 Daikin AC
A (02/2006)
Set up password protection in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 47 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 48 REV
2005 Daikin AC
A (02/2006)
Set up backlight profile in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 49 REV
2005 Daikin AC
A (02/2006)
Set up backlight profile in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 50 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 51 REV
2005 Daikin AC
A (02/2006)
Managing history in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 52 REV
2005 Daikin AC
A (02/2006)
Managing history in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 53 REV
2005 Daikin AC
A (02/2006)
Managing history in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 54 REV
2005 Daikin AC
A (02/2006)
Managing history in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 55 REV
2005 Daikin AC
A (02/2006)
Managing history in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 56 REV
2005 Daikin AC
A (02/2006)
Managing history in the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 57 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 58 REV
2005 Daikin AC
A (02/2006)
Establishing and managing zones and groups within the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 59 REV
2005 Daikin AC
A (02/2006)
Establishing and managing zones and groups within the iTouch Controller
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 60 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 61 REV
2005 Daikin AC
A (02/2006)
Changing icon colors
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 62 REV
2005 Daikin AC
A (02/2006)
Changing icon colors
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 63 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 64 REV
2005 Daikin AC
A (02/2006)
Managing iTouch Controller Schedules
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 65 REV
2005 Daikin AC
A (02/2006)
Managing iTouch Controller Schedules
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 66 REV
2005 Daikin AC
A (02/2006)
Managing iTouch Controller Schedules
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 67 REV
2005 Daikin AC
A (02/2006)
Managing iTouch Controller Schedules
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 68 REV
2005 Daikin AC
A (02/2006)
Managing iTouch Controller Schedules
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 69 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 70 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Heating Mode Optimization
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 71 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 72 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Automatic Change-Over Feature
Indoor unit will change from cooling to heating or vice versa when a certain
temperature is reached.
Some terminology:
Differential: user selected temperature difference to initiate a mode change
from current setpoint
Different changeover methods
OFF
Fixed : One indoor decides the changeover, even if that unit is off.
Operating : One indoor unit is the reference unit, but only if the unit is ON :
If the unit is OFF, the next unit on the list (that is ON) becomes the reference.
Average : Several indoor units are used to calculate an average unit that is used as reference.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 73 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 74 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Temperature Limit Feature
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 75 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Temperature Limit Feature
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 76 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Temperature Limit Feature
This feature automatically starts and stops air conditioners
in order to prevent the room temperature of unoccupied
rooms from getting too hot or too cold.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 77 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Temperature Limit Feature
The extended range of the upper and lower temperature limit function make this a
relatively poor substitute for a true set-back and set-up control scheme
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 78 REV
2005 Daikin AC
A (02/2006)
iTouch logic flow and control hierarchy
Settings Mode
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 79 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Simple Interlock Function
The simple interlock feature of the iTouch Controller gives a system designer
the flexibility to automate occupancy and energy savings tasks in a variety of
residential and commercial environments.
The Daikin Di and Dio peripherals serve as the core interface apparatus to
realizing external control through the simple interlock function.
OFF command
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 80 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Simple Interlock Function
Please consider that all addressable Di and Do points consume an address
point normally reserved for a group or group of indoor units.
OFF command
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 81 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Simple Interlock Function
Up to 128
interlock
programs possible
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 82 REV
2005 Daikin AC
A (02/2006)
iTouch Controllers Simple Interlock Function
Not detect
Something turned
on
All turned on
Something turned
off
All turned off
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 83 REV
2005 Daikin AC
A (02/2006)
iTouch Controller Web Access
Internal and External Access Requirements
2005 Daikin AC
Web Access Functionality and Control
Users PC
Ethernet (straight)
HUB
Ethernet (straight)
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 85 REV
2005 Daikin AC
A (02/2006)
Web Access Functionality and Control
http://192.168.0.1
HTTP:// address of
the ITC
e.g. http://192.168.0.1
Enter username
and password
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 86 REV
2005 Daikin AC
A (02/2006)
Web Access Functionality and Control
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 87 REV
2005 Daikin AC
A (02/2006)
Web Access Functionality and Control
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 88 REV
2005 Daikin AC
A (02/2006)
Web Access Functionality and Control
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 89 REV
2005 Daikin AC
A (02/2006)
Web Access / User Administration
Display for 4th floor
user Up to 64 users that can use
4F the web function can be
registered.
Administrators screen
2F
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 90 REV
2005 Daikin AC
A (02/2006)
Web Access Network Engineering
Access Configuration Application Network Configuration Security
Local Area Network Commercial Ethernet Hub Depends upon the security level
Internal / Private Network Residential of the internal network
Simple internal access only Generally very secure
Access managed by iTouch
Controller (Username / Password)
Account/
Password
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 91 REV
2005 Daikin AC
A (02/2006)
Web Access Network Engineering
Access Configuration Application Network Configuration Security
Dial-Up Connection (Analog) Multi-tenant sites Router with dial-up capability Depends upon the security level
Remote Connection Chain stores RAS (remote access server) + of the internal network
Large residential modem on the PC is a possible Generally very secure
combination Access managed by iTouch
Controller (Username / Password)
INSIDE OUTSIDE
Account/ TEL-No.
Password Account/
Password
Dialup Dialup
Router
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 92 REV
2005 Daikin AC
A (02/2006)
Web Access Network Engineering
Access Configuration Application Network Configuration Security
Internet Connection Commercial DSL, Cable Modem, T1 Low to moderately security
ISP Provisioned Residential Static IP Address solution
Retail Access managed by iTouch
Multi-tenant (ISP assigned dynamic IP address Controller (Username / Password)
with Dynamic DNS service) ONLY
INSIDE OUTSIDE
Account/
DDNS
Password
Permanent Internet
connection
ISP ISP
DDNS : If IP address is not static, you have to use DDNS for resolving dynamic IP
address assigned by the ISP.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 93 REV
2005 Daikin AC
A (02/2006)
Web Access Network Engineering
Access Configuration Application Network Configuration Security
Internet Connection Commercial DSL, Cable Modem, T1 High security solution
ISP Provisioned Residential Static IP Address VPN Username and Password
VPN (Virtual Private Network) Retail VPN Access managed by iTouch
Multi-tenant (ISP assigned dynamic IP address Controller (Username / Password)
with Dynamic DNS service) ONLY
INSIDE OUTSIDE
Account/
DDNS
Password
Permanent InterNet
connection
ISP
ISP
Account/
Password
ADSL
Mode/Router
with VPN
VPN
Client
DDNS : If IP address is not static, you have to use DDNS for resolving dynamic IP
address assigned by the ISP.
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 94 REV
2005 Daikin AC
A (02/2006)
Web Access / Email Notification
Internet
Internet
In company
Mail server
LAN
HUB
ERROR
error
Technician
HRV
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 95 REV
2005 Daikin AC
A (02/2006)
Daikins iTouch
Presentation Controller
Title : Presenter Name
Features and :Capabilities
Date Slide 96 REV
2005 Daikin AC
A (02/2006)