Anda di halaman 1dari 37

Makapuyat National High School

Commitment to Excellence
MULTITESTER
Commitment to Excellence
2 KINDS OF MULTITESTER

ANALOG MULTITESTER
Commitment to Excellence
2 KINDS OF MULTIESTER

DIGITAL MULTITESTER
Commitment to Excellence
MULTIMETER
Is an indispensable for a technician as firearms for a
Soldier. The interpretation of readings gives technician
Clues to trouble-shooting.
Zero ohms adjustments:

Use to set the pointer exactly


On zero position at the right
side of meter panel
Zero corrector:
Use to set the meter pointer to
Zero position at the left side of
The meter panel
Range selector:
It is used to adjust the proper
Function range for specific
measurement
Dial pointer
Dial scale:
Voltmeter: is an instrument is used
Measuring voltage or potential
difference

Observed polarity in measuring


DC voltage and current.

Always set at higher range of meter

DC voltage
range

SYSTEMS PLUS COMPUTER COLLEGE


1. Before taking a measurement,
the pointer position should be
confirmed to zero on the top
ohm scale.
2. With the + and COM terminals
shorted together, the meter is
adjusted by turning the zero
ohm adj. to the right or left in
order to place on zero at right.
3. Always set the meter pointer on
the highest range of there
function, if measuring an unknown
voltage or current.

AC voltage range

SYSTEMS PLUS COMPUTER COLLEGE


Ohmmeter : is an instrument
Used for measuring resistance.

Always remember the:

1. Zero ohms adjustment


2. Zero corrector

Resistance
Test probe
+&-
PARTS OF MULTITESTER

Front panel
Dial scale

needle pointer

Zero corrector

Zero ohms
adjustment AC voltage range

DC voltage
Dial selector

Test prove/ resistance


socket
Commitment to Excellence
Voltmeter:

Is used when it is
necessary to
determine the
presence or absence
of an electrical
pressure or voltage on
a unit under test.

Tester has two voltmeter


functions:

1. AC or alternating
current
2. DC or Direct current
DC VOLTMETER:

1. When operating on .1 volt range, we utilize the 10 volts scale and


Shift the decimal two places to the left. (.01 as multiplier )

Range used Scale used Scale reading multiplier Actual reading

DCV/0.1 0-10 4.4 .01 0.44


DC VOLTMETER:

2. If the instrument is
operated on 0.5 v range,
we utilize the 50 v
scale and move the
decimal point two places
to the left.
(.01 as multiplier )

Range used Scale used Scale reading multiplier Actual reading

DCV/0.1 0-10 4.4 .01 0.44


DCV/.5 0-50 22 .01 0.22
DC VOLTMETER:

3. When VOM is set to 2.5 v


range, we use the 250 v
scale and shift
the decimal point two
laces to d left ( .01 as
multiplier )

Range used Scale used Scale reading multiplier Actual reading

DCV/0.1 0-10 4.4 .01 0.44


DCV/.5 0-50 22 .01 0.22
DCV/2.5 0-250 110 .01 1.10
DC VOLTMETER:

4. VOM is operated on 10 v
range,
we utilize the 10 v scale and
read directly or set 1 as
multiplier

Range used Scale used Scale reading multiplier Actual reading

DCV/0.1 0-10 4.4 .01 0.44


DCV/.5 0-50 22 .01 0.22
DCV/2.5 0-250 110 .01 1.10
DCV/10 0-10 4.4 1 4.4
DC VOLTMETER:

5. VOM is operated on 50 v
range, we utilize the 50 v
scale and read
directly or set 1 as
multiplier

Range used Scale used Scale reading multiplier Actual reading

DCV/0.1 0-10 4.4 .01 0.44


DCV/.5 0-50 22 .01 0.22
DCV/2.5 0-250 110 .01 1.10
DCV/10 0-10 4.4 1 4.4
DCV/50 0-50 22 1 22
DC VOLTMETER:

6. VOM is operated on 250 v


range, we utilize the 250 v
scale and read
directly or set 1 as
multiplier

Range used Scale used Scale reading multiplier Actual reading

DCV/0.1 0-10 4.4 .01 0.44


DCV/.5 0-50 22 .01 0.22
DCV/2.5 0-250 110 .01 1.10
DCV/10 0-10 4.4 1 4.4
DCV/50 0-50 22 1 22
DCV/250 0-250 110 1 110
DC VOLTMETER:
7. VOM is operated on 1000 v
range, we utilize the 25 v
scale and
shift decimal point two
places to d right ( 100 as
multiplier )

Range used Scale used Scale reading multiplier Actual reading

DCV/0.1 0-10 4.4 .01 0.44


DCV/.5 0-50 22 .01 0.22
DCV/2.5 0-250 110 .01 1.10
DCV/10 0-10 4.4 1 4.4
DCV/50 0-50 22 1 22
DCV/250 0-250 110 1 110
DCV/1000 0-10 4.4 100 440
DC VOLTMETER

Range used Scale used Scale reading multiplier Actual reading

DCV/0.1 0-10 4.4 .01 0.44


DCV/.5 0-50 22 .01 0.22
DCV/2.5 0-250 110 .01 1.10
DCV/10 0-10 4.4 1 4.4
DCV/50 0-50 22 1 22
DCV/250 0-250 110 1 110
DCV/1000 0-10 4.4 100 440
AC VOLTMETER READING
AC VOLTMETER READING CHART

Range Scale Scale multiplier Actual


used used reading reading
ACV/10 0-10 2.4 1 2.4

ACV/50 0-50 12 1 12

ACV/250 0-250 60 1 60

ACV/1000 0-10 2.4 100 240


DC CURRENT METER
1. 50 Micro ampere range,
we utilize the 50 v
scale and
read directly

RANGE SCALE SCALE MULTIPLIER ACTUAL


USED USED READING READING
DCA/50 UA 0-50 32 1 32UA
DCA/2.5MA 0-250 160 .01 1.6MA
DCA/25 MA 0-250 160 .01 1.6MA

DCA/.25A 0-250 160 .001 .16A


2. To read current in the 2.5ma range, read the 0-250
and move decimal point to places to d left

RANGE SCALE SCALE MULTIPLIER ACTUAL


USED USED READING READING
DCA/50 UA 0-50 32 1 32UA

DCA/2.5MA 0-250 160 .01 1.6MA

DCA/25 MA 0-250 160 .01 1.6MA

DCA/.25A 0-250 160 .001 .16A


3. Move decimal point just once to the left

RANGE SCALE SCALE MULTIPLIER ACTUAL


USED USED READING READING

DCA/50 UA 0-50 32 1 32UA

DCA/2.5MA 0-250 160 .01 1.6MA

DCA/25 MA 0-250 160 .01 1.6MA

DCA/.25A 0-250 160 .001 .16A


4. Move decimal point 3 places to d left

RANGE SCALE SCALE MULTIPLIER ACTUAL


USED USED READING READING

DCA/50 UA 0-50 32 1 32UA

DCA/2.5MA 0-250 160 .01 1.6MA

DCA/25 MA 0-250 160 .01 1.6MA

DCA/.25A 0-250 160 .001 .16A


Commitment to Excellence

Testing voltage:

From battery which


Is a DC voltage
PARTS OF MULTITESTER

1
7

8 6
3
4

9
10

Anda mungkin juga menyukai