Anda di halaman 1dari 14

TRACERCO DiagnosticsTM

Leak study
A range of technologies
that enable the location and
extent of leaks to be
accurately determined
within process vessels and
pipelines, both on and off
line.
TRACERCO DiagnosticsTM
Leak study
Technology
Sophisticated tracer technology
Active
Stable chemical
Advanced detection
Non-intrusive (active)
Sample & analysis (chemical)
Specialised injection systems
Safe & reliable
TRACERCO DiagnosticsTM
Leak study
Features of technique
On-line leak detection
Active tracers
Gaseous,organic & aqueous
Mimic process fluids
Short half-life
Non-intrusive detection
No effect on process
Leaks down to 1%
TRACERCO DiagnosticsTM
Leak study
Features of technique
On-line leak detection
Active tracers
Stable chemical tracers
Gaseous,organic & aqueous
Mimic process fluids
Samples required
Environmentally friendly
No effect on process
Detection levels p.p.b.
Leaks down to 2%
TRACERCO DiagnosticsTM
Leak study
Features of technique
On-line leak detection
Off-line leak detection
Helium leak detection
Hand held monitor
TRACERCO DiagnosticsTM
Leak study
Features of technique
On-line leak detection
Off-line leak detection TRACER
INJECTION
POINT
REACTOR

Suitable for BYPASS PEAK


MAIN PEAK

Heat exchangers BYPASSING

DISPLAY


DETECTOR

Reactors OUTPUT

Relief valves
Converters
TRACERCO DiagnosticsTM
Leak study
Benefits of technique
Reduce shutdown periods
Identify precise leak location
Rapidly back on-line
Minimise shutdown costs
Inspection costs during shutdown
Cost of lost production
Increase operating confidence
Pre-commissioning leak tests
TRACERCO DiagnosticsTM
Leak study
Case study 1 - Feed effluent Exchanger
Problem
Feed effluent heat exchangers
Bank of three exchanger
Poor product quality
Reactor performance OR leakage
Options
Take exchangers off-line
Test individually
Carry out TRACERCO DiagnosticsTM Leak study
TRACERCO DiagnosticsTM
Leak study
Case study 1 - Feed effluent Exchanger
Study
Active tracer injected into feed
Detectors on exit of each exchangers
Results back to central computer
3 injections - same results Reactor

Feed
Tracer
Injection
D5
No.1 No.2 No.3

Effluent
(Product)
D1 D2 D3 D4
TRACERCO DiagnosticsTM
Leak study
Case study 1 - Feed effluent Exchanger
Outcome
Identified exchanger No. 2 leaking
Approximately 7% leakage
Able to plan shutdown requirements
Minimised cost and time associated with
heat exchanger repair
TRACERCO DiagnosticsTM
Leak study
Case study 2 - Shell & Tube Exchanger
Problem
Offline heat exchanger
Known to leak
Need to repair leak
250 tubes
Options
Replace exchanger
Identify leaking tubes with TRACERCO
DiagnosticsTM Leak study (Helium)
TRACERCO DiagnosticsTM
Leak study
Case study 2 - Shell & Tube
Exchanger
Study
All tubes blocked (bunged)
Mixture of He & N injected on
shell side
12 hour soak time
Each individual tube tested
Hand held helium mass
spectrometer
TRACERCO DiagnosticsTM
Leak study
Case study 2 - Shell & Tube Exchanger
Outcome
12 tubes confirmed as leaking
Tubes blocked off
Heat exchanger back on-line with 24 hours
Process operating satisfactorily
Eliminated cost of repairing or replacing
whole heat exchanger
TRACERCO DiagnosticsTM
Leak study
A range of technologies
that enable the location and
extent of leaks to be
accurately determined
within process vessels and
pipelines, both on and off
line.

Anda mungkin juga menyukai