Module objectives

Upon completion of this module, you should be able to:

Describe MPT-HC power, ground, and data cabling


Describe the lightning surge suppressor

323 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
1 MPT-HC System Grounding

Refer to 9500 MPR Installation Practices, Chart 10, 15,


and 16, or
9500 MPR Indoor: MSS-1/MSS-4/MSS-8 + Outdoor:
MPT-HC/MPT-HC V2/MPT-XP/MPT-MC User Manual, for
more details
327 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.
Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
1 MPT-HC System Grounding
1.1 Cable Grounding

The power supply and the Ethernet electrical cables must be grounded by
using dedicated grounding kits.

328 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
1 MPT-HC System Grounding
1.2 MPT-HC Grounding

Each MPT-HC must be grounded individually.


The RF coupler and antenna do not require grounding.

MPT-HC grounding connector is


connected with a grounding cable
to the nearest grounding plate

329 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
1 MPT-HC System Grounding
1.3 Locations for Cable Grounds

3 2 10 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
1 MPT-HC System Grounding
1.4 Cable Grounds: Surge Suppressor Outside Building

If the surge suppressor is installed between the building and the building
entry cable ground kit, recommended location, the suppressor ground
must not double as the building-entry cable ground.
A separate ground kit must be installed on the tower side of the
suppressor.

3 2 11 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
1 MPT-HC System Grounding
1.5 Cable Grounds: Surge Suppressor Inside Building

If the surge suppressor is installed inside the building, it must be installed


as close as practical to cable entry and connected directly to the master
ground bar or ground bar extension.
A separate ground kit must be installed where the cable enters the
building.

3 2 12 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
2 Lightning Surge Suppressor

Refer to 9500 MPR Installation Practices, Chart 14,


or
9500 MPR Indoor: MSS-1/MSS-4/MSS-8 + Outdoor:
MPT-HC/MPT-HC V2/MPT-XP/MPT-MC User Manual, for
more details
3 2 13 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.
Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
2 Lightning Surge Suppressor
2.1 Lightning Surge Suppressor

The suppressor is an in-line matrix type. It has a DC-blocked RF path


with multiple protection stages in the parallel DC path.
The suppressors are designed to withstand repeated strikes up to 15 kV,
and in the event they do fail to hard-fail so as not to cause uncertain or
intermittent operation.
The recommended installation has one suppressor installed at building
entry (MPT-HC surge suppressor is internal to unit).
The suppressor kit includes connectors, ground wire, ground clamp,
waterproofing tape, and support bracket for use at an MPT-HC
installation.

3 2 14 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
2 Lightning Surge Suppressor
2.2 Locations for Surge Suppressor

ODU and antenna

Cable ground

ODU ground wire(s)

Cable ground

3 2 15 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
2 Lightning Surge Suppressor
2.3 Surge Suppressor Inside Building

3 2 16 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
2 Lightning Surge Suppressor
2.4 Surge Suppressor Outside Building

3 2 17 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
3 MPT-HC Power and Data Cables

Refer to 9500 MPR Installation Practices, Chart 10,


or
9500 MPR Indoor: MSS-1/MSS-4/MSS-8 + Outdoor:
MPT-HC/MPT-HC V2/MPT-XP/MPT-MC User Manual, for
more details
3 2 19 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.
Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
3 MPT-HC Power and Data Cables
3.1 MPT-HC to MSS-4/8 Connections

Cable connections to the MPT-HC depend upon the system configuration


deployed.
Cable connections to the MPT-HC are as follows:
Cat7e: XPIC Interconnect

RJ-45/R2CT Cat5e cable: Electrical


Ethernet Data and Power (PFoE)

LC/Q-XCO: 1+1 RPS Interconnect

SFP LC/Q-XCO: Optical Ethernet


Data

3 2 20 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
3 MPT-HC Power and Data Cables
3.1 MPT-HC to MSS-4/8 Connections [cont.]

Cat7e: XPIC Interconnect

XPIC Cat7 cable

3 2 21 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
3 MPT-HC Power and Data Cables
3.1 MPT-HC to MSS-4/8 Connections [cont.]

RJ-45/R2CT Cat5e cable: Electrical Ethernet Data and Power (PFoE)


If PFoE is used, a single cable connects
the MPT-HC with the MSS-4/8 or DC
Injector is required.

3 2 22 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
3 MPT-HC Power and Data Cables
3.1 MPT-HC to MSS-4/8 Connections [cont.]

LC/Q-XCO: 1+1 RPS Interconnect

RPS cable

3 2 23 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
3 MPT-HC Power and Data Cables
3.1 MPT-HC to MSS-4/8 Connections [cont.]

SFP LC/Q-XCO: Optical Ethernet Data

MPT-HC grounding connector is


connected with a grounding cable
to the nearest grounding plate

Cat 5e cable for DC Core-E module


power to station battery

Power Injector option Optical Ethernet cable

MPT Power Unit option


3 2 24 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.
Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
Module summary

In this module, we have covered:


MPT-HC/MPT-XP power, ground, and data cabling
Lightning surge suppressor

3 2 25 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)
End of module
MPT-HC Cabling

3 2 26 COPYRIGHT ALCATEL-LUCENT 2013. ALL RIGHTS RESERVED.


Outdoor Units MPT-HC Cabling
9500 MPR (Microwave Packet Radio) R4.2 Installation and Turn Up (ANSI/ETSI)