Mechanical Works
Power Plan
Pumps
Prepared by:
Eng. Khamis Farag
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 2 6th June 2011 / Rev.2
Contents
12 Cavitation in centrifugal pumps 212
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 3 6th June 2011 / Rev.2
Pump Training
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 4 6th June 2011 / Rev.2
INTRODUCTION
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 5 6th June 2011 / Rev.2
Introduction
Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 6 6th June 2011 / Rev.2
What is a Pump?
A device that raises, transfers, or compresses fluids by suction or
pressure or both.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 7 6th June 2011 / Rev.2
PUMPS CLASSIFICATION
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 8 6th June 2011 / Rev.2
Pump Classification
Pumps
Positive
Dynamic
Displacement
Piston,
Multiple Rotor Single Rotor Diaphragm
Plunger
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 9 6th June 2011 / Rev.2
Displacement Pumps
Lope pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 10 6th June 2011 / Rev.2
Positive Displacement Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 11 6th June 2011 / Rev.2
Dynamic Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 12 6th June 2011 / Rev.2
Dynamic Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 13 6th June 2011 / Rev.2
Type of Pumps
Dynamic pumps
Mode of operation
Rotating impeller converts kinetic energy into pressure or velocity to pump the fluid
Two types
Centrifugal pumps: pumping water in industry 75% of pumps installed
Special effect pumps: specialized conditions
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 14 6th June 2011 / Rev.2
Type of Pumps
Centrifugal Pumps
How do they work?
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 15 6th June 2011 / Rev.2
Overhung
End suction
API Standard
Process Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 16 6th June 2011 / Rev.2
CENTRIFUGAL PUMPS COMPONENTS
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 17 6th June 2011 / Rev.2
Centrifugal Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 18 6th June 2011 / Rev.2
Rotating Components
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 19 6th June 2011 / Rev.2
Rotating Components
Centrifugal Pumps
Impeller
Main rotating part that provides centrifugal
acceleration to the fluid
Number of impellers = number of pump stages
Impeller classification: direction of flow, suction
type and shape/mechanical construction
Shaft
Transfers torque from motor to impeller during
pump start up and operation
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 20 6th June 2011 / Rev.2
IMPELLERS
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 21 6th June 2011 / Rev.2
Impeller
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 22 6th June 2011 / Rev.2
Impellers
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 23 6th June 2011 / Rev.2
Impellers
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 24 6th June 2011 / Rev.2
Impellers (Direct of Flow)
On a radial flow impeller the vane surfaces are generated by straight lines
parallel to the axis of rotation is the pump shaft. Flow strictly follows a line
perpendicular to this axis of rotation. The liquid enters the impellers at the
hub and flows radially to the periphery. In other words, the liquid enters the
impeller and makes a 90o turn and runs parallel to the vanes until it exits the
impeller at the vane tips.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 25 6th June 2011 / Rev.2
Radial Flow
In an axial flow impeller the vane surfaces are perpendicular to the axis
of rotation. On most pumps the axis of rotation is the pump shaft.
Flow strictly parallels this axis of rotation. The liquid enters the pump inlet
axially and discharge nearly axially. This means the flow enters the
impeller and keeps on going straight through, parallel to the shaft.
Pumps thats use these types of impellers are sometimes called propeller
pumps.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 27 6th June 2011 / Rev.2
Axial Flow
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 29 6th June 2011 / Rev.2
Mixed Flow
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 30 6th June 2011 / Rev.2
Impellers
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 31 6th June 2011 / Rev.2
Axial Flow Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 32 6th June 2011 / Rev.2
Mixed Flow Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 33 6th June 2011 / Rev.2
Impellers Shap
Another method of classifying impellers is by mechanical design.
As such, impellers defined in this manner ca be designed as open, semi-
open, or closed.
Impellers are usually manufactured using one of two casting processes.
Sand casting uses a sand mold into which molten metal is poured and
allowed to cool. Sand casted impellers are the most common and least
expensive to produce. However, they very often leave a rough surface on
the wetted areas of the impeller. This can lead to lower pump efficiencies.
Investment casting uses a mold more from an extremely viscous (and
expensive) waxy like material.
Molten metal is poured into this mold.
As the metal cools, the mold melts leaving a smooth metal surface.
Impellers made this way are usually more expensive to produce than
sand casted impellers. however, because they leave a much smoother
surface on the wetted areas of the impeller, higher pump efficiencies are
often achieved.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 34 6th June 2011 / Rev.2
Open Impeller
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 35 6th June 2011 / Rev.2
Semi-Open Impeller
Semi-open impeller
A semi-open impeller uses a
single shroud, usually at the back
of the impeller.
This shroud may or may not have
pump out vanes or balance holes
to modify the pressure behind the
impeller.
Semi-Open Impeller
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 36 6th June 2011 / Rev.2
Closed Impeller
Closed impeller
A closed impeller uses shrouds that
totally enclose the impeller from the
suction eye to its edges.
This design prevents liquid slippage
from the discharge to suction by
using a running joint between the
casing and the impeller. This running
joint is often called a wear ring.
Semi-Open Impeller
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 37 6th June 2011 / Rev.2
If the pump is one in which the head is developed by a single impeller, it is
called a single-stage pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 38 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 39 6th June 2011 / Rev.2
Pumps Shaft
Pump shaft
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 40 6th June 2011 / Rev.2
Stationary Components
Centrifugal Pumps
Casings
Functions
Enclose impeller as pressure vessel
Support and bearing for shaft and
impeller
Volute case
Impellers inside casings
Balances hydraulic pressure on pump
shaft
Circular casing
Vanes surrounds impeller
Used for multi-stage pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 41 6th June 2011 / Rev.2
Volute
The volute, or casing as it is sometimes referred to, is a spiral-shaped
Component surrounding the impeller.
This section provides a path to accept and discharge the fluid being
pumped.
On the most overhung impeller centrifugal pumps, each casing has an
inlet (section) side and outlet (discharge) side. The fluid to be pumped is
fed under pressure to the inlet side of the pump. The casing collects this
fluid discharged by the impeller and converts its velocity energy to
pressure energy. The fluid then leaves the casing through the outlet at a
higher pressure.
A centrifugal pump volute increase in area from its initial points until it
encompasses the full 360o around the impeller and then flares out to the
final discharge opening. The wall dividing the initial section and the
discharge nozzle portions of the volute or the cutwater on many
centrifugal pumps (especially horizontal end-suction) is usually
positioned at approximately the 0o (top) position.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 42 6th June 2011 / Rev.2
Volute
External view of volute looking inside Internal view of volute showing impeller
(Note: Impeller is visible) rotation and fluid flow
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 43 6th June 2011 / Rev.2
Casing and Diffusers
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 44 6th June 2011 / Rev.2
Centrifugal Pump
Volute Diffuser
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 45 6th June 2011 / Rev.2
Solid and Split Casings
It must have one side open so that the impeller may be introduced into the
casing. As the sidewalls surrounding the impeller are in reality part of the
casing, a solid casing, strictly speaking, cannot be used, and designs
normally called solid casing are really radially split.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 46 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 47 6th June 2011 / Rev.2
End-Suction Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 48 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 49 6th June 2011 / Rev.2
Nozzle Locations
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 50 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 51 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 52 6th June 2011 / Rev.2
The Frontcover
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 53 6th June 2011 / Rev.2
The Backcover
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 54 6th June 2011 / Rev.2
Section 2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 55 6th June 2011 / Rev.2
WEARING RINGS
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 56 6th June 2011 / Rev.2
Pump Wear Rings
Between the pump
Casing and the hub
Seal is between the lower
pressure of the intake side
and the higher pressure in
the volute.
Dirt/sediment can damage
ring resulting in decreased
pump effectiveness
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 57 6th June 2011 / Rev.2
The Wear Ring
Wear rings are sacrificial components
installed on the casing and impeller to
inhibit fluid from recirculating back to
suction from the discharge they
provide a renewable restriction
between a closed impeller and the
casing. Wear rings are often installed
on both the front and back of the
impeller. When wear rings are
installed on the back of the impeller,
another set of rings is installed in the
backcover.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 58 6th June 2011 / Rev.2
Nomenclature for the casing or stationary part forming the leakage joint
surface is as follows:
Casing ring (if mounted in the casing)
Suction-cover ring or suction-head ring (if mounted in a suction cover
or head
Stuffing-box-cover ring or head ring (if mounted in the stuffing box
cover or head.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 59 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 60 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 61 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 62 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 63 6th June 2011 / Rev.2
Wearing-Ring Clearances
Typical clearance and tolerance standards for nongalling wearing joint
metals in general service pumps are shown. They apply to the following
combinations:
Bronze with a dissimilar bronze
Cast iron with bronze
Steel with bronze
Monel metal with bronze
Cast iron with same casing vary over a wide range, the design is
impractical in regular pump lines.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 64 6th June 2011 / Rev.2
Sealing Device
Pump Packing
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 65 6th June 2011 / Rev.2
Sealing Device
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 66 6th June 2011 / Rev.2
The Stuffing Box
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 67 6th June 2011 / Rev.2
The Pump Stuffing Box Jacket
In some services, high temperatures can complicate the problem of
maintaining the sealing device within the stuffing box. Pumps in these
services are usually provided with jackets, liquid-cooled stuffing boxes. A
head transfer medium (usually water) reduces the temperature of the
fluid being pumped, only in the stuffing box area and not in the volute.
The temperature in the stuffing box is reduced by the flow of water
completely surrounding the stuffing box.
In rare occasions, the pump stuffing box, jacket is actually used to keep a
fluid warm or even hot. Liquids that need a jacket for the heating instead
of cooling. Without this external source of heat to keep it warm, the fluid
would solidify or at least become extremely viscous. This greatly reduces
the life of any sealing device.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 68 6th June 2011 / Rev.2
The Pump Stuffing box Jacket
Pump jacket. Note the restriction bushing in the bottom of the seal chamber
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 69 6th June 2011 / Rev.2
The Lantern Ring
The function of the lantern ring is to establish a liquid seal around the
shaft and to provide a path to inject lubrication, thus reducing the heat
generation of the stuffing box packing. This ring can be made from softer
metals (like brass), carbon and various polymers ( like PTFE).
Another common name for lantern ring is seal cage.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 70 6th June 2011 / Rev.2
The Lantern Ring
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 71 6th June 2011 / Rev.2
Sealing Device
The basics
Mechanical seals are leakage control device, which
are found on rotating equipment such as pumps and
mixers to prevent the leakage of liquids and gases
from escaping into the environment. Figure 1 shows
a typical centrifugal pump, which highlights its
Figure 1
constituent parts, including the mechanical seal.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 72 6th June 2011 / Rev.2
Sealing Device
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 73 6th June 2011 / Rev.2
Sealing Device
Design
By way of example, a simple mechanical seal design has 7 components(Figure 3):
1) Stationary component; commonly referred to as the seat.
2) Stationary component sealing member. Figure 3
3) Rotating component.
4) Rotating component sealing member
5) Spring.
6) Gland plate.
7) Clamp ring.
A mechanical seal has 4 main sealing points(indicated by orange circles as per figure 3):
The seal between the rotating (3) and stationary faces (1). This is known as the primary seal.
The seal between the stationary member (1) and stuffing box face, i.e. Gasket (2).
The seal between the rotating member and the shaft or shaft sleeve (4). This is know as the
secondary seal and may be an o-ring as shown, a v-ring, a wedge or any similar sealing ring.
The seal between the gland plate and stuffing box, this is usually a gasket, or o-ring
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 74 6th June 2011 / Rev.2
Sealing Device
Mechanical seal
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 75 6th June 2011 / Rev.2
MECHANICAL SEALS
PART 1:
PRIMARY
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 76 6th June 2011 / Rev.2
Fig 1: Fig 2:
Mechanical seals are essentially two flat polished Let us simplify the idea and imagine the seal
cut
rings that rub against one another, held in contact
through in section. Bear in mind that the shaft
by a series of springs. or
Component (1) called the seat is normally spindle that is being seals passed through the
stationary and sealed into the housing. middle of these rings.
Component (2) called the face rotates with the
shaft.
The liquid being seals provides a lubricant that
prevents the faces making physical contact.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 77 6th June 2011 / Rev.2
Fig 3 Fig 4
In sealing terminology there are these three This shows a common method using O Ring
sealing points on a mechanical seal: for sealing the secondary and tertiary sealing
Primary Sealing Point Is the contact area points. These O Ring seals are described
between the face and seat. more fully in other modules, but are commonly
used by John Crane in synthetic rubber
2. Secondary Sealing Point Is where the materials.
mechanical seal makes contact with the shaft and O Rings are excellent in most static
slides along it to accommodate wear. applications but they do have serious
3. Tertiary Sealing Point Is where the seat fits into limitations in some areas.
the housing of the equipment and prevents There are very many different methods of
leakage around the back. sealing secondary
In practical terms the components shown cannot and tertiary points depending upon the
be fixed permanently in position. The face and experience of the seal manufacturer involved.
seats must be slightly flexible to allow for However, all face contact spring loaded
movement and misalignment that inevitable takes mechanical seals work on the same basic
place. principles.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 78 6th June 2011 / Rev.2
Part 2:
THE SECONDARY SEAL
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 79 6th June 2011 / Rev.2
Fig 2
Fig 1 The main purpose of the secondary sealing
In the previous module you saw this drawing and device is to prevent leakage of fluid through
we explored the seal concepts where leakage the bore of the seal along the shaft.
must be prevented at the three points shown. In this particular case it is normal to use one of
Let us look at the secondary seal (2) and three design methods at the secondary
examine sealing point.
its purpose and method of operation. O RINGS
WEDGE RINGS
BELLOWS
It is a common practice to describe the seal by
its secondary sealing device: Wedge seals,
bellows seal, etc. All secondary sealing
devices clearly divide into two main groups,
those that slide along the shaft (pusher seals)
and those that do not slide along the shaft
(non-pusher)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 80 6th June 2011 / Rev.2
Fig 3 Fig 4
O Ring secondary seals are effective at this The O ring is pushed into the corner of the
point, but due to the small clearances required housing by hydraulic pressure. This closes the
they only have marginal flexibility. gap in the bore of the face.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 81 6th June 2011 / Rev.2
Fig 5 Fig 6
The second method of sealing on the shaft is to Movement is allowed by the bellows flexing or
use a bellows. extending and therefore it is described as a
nonpusher seal.
The actual sealing point becomes remote from
The actual mechanism of sealing the shaft can be
the face allowing a great deal more flexibility.
varied dependent upon the duty conditions and
The sealing point is fixed on the shaft and does
the materials of construction.
not have to slide to accommodate wear of the
Rubber bellows normally grip the shaft with an
face.
interference fit created by a metal drive ring. The
drive ring creates a squeeze effect on the tail.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 82 6th June 2011 / Rev.2
Part 3:
DRIVE METHODS
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 83 6th June 2011 / Rev.2
Fig 1 Fig 2
In the now familiar design of a mechanical seal, One of the most common forms of drive is a
one element rotates against another which is Peg.
stationary. This is normally a length of solid round metal
fixed into a hole in the driving shaft and
The devices used to ensure that the elements
protruding into a slot in the driven component.
rotate or remain stationary are called Drive
Methods.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 84 6th June 2011 / Rev.2
Fig 3 Fig 4
Pegs fitted to stationary components are A combination of the peg and grubscrew can
preferred, because if fitted in rotating be used in a Drive Collar.
components they can be subject to vibration The drive collar can be locked to a rotating
and work loose. Where possible they should be shaft using a grubscrew and peg fitted a
a tight fit in a substantial piece of metal. shown to locate in a driven component.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 85 6th June 2011 / Rev.2
Part 4:
SPRINGS
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 86 6th June 2011 / Rev.2
Fig 1 Fig 2
A mechanical seal helical spring used for Multiple spring sets are usually small in
compressive purposes needs to be ground on its diameter, as each spring presents a parallel
ends to present parallel contact areas (2). This contact area the loading on the rubbing face is
evenly distributes the spring loading at the back of very uniform. They can, however, become
clogged with debris if present in the liquid
the rubbing face, otherwise cocking can occur
being sealed.
(1).
As a helix can only be ground flat over 75% of its
contact area, it is essential that both ends of the
spring are in line to reduce the cocking effect (2).
On a single spring seal, the loading on the face is
not 100% uniform.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 87 6th June 2011 / Rev.2
Fig 3 Fig 4
Multiple springs sets need some form of For a single spring the locating ring (1) and
containment to space them out evenly around drive sleeve (2) maintain the shape and
a circumference and to prevent loss. relative position of the spring.
A retainer provides the necessary
containment.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 88 6th June 2011 / Rev.2
Fig 6
The design or type of spring used in a
mechanical seal is dependent upon a number
of factors.
Materials of construction
Corrosion Levels
Shaft Diameter
Load Required
Space Available
Face Wear Allowance
Fig 5
Amount of Axial Movement Required
Here are two more variations of the combined
spring and drive method used by:- Speed and direction of rotation
The formed asymmetrical metal bellows The nature of the fluid being handled:
The edge welded metal bellows Solids in suspension
Viscosity
Solidification
Crystallization
Process Temperature
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 89 6th June 2011 / Rev.2
SPRING TYPE ADVANTAGES DISDVANTAGES
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 90 6th June 2011 / Rev.2
Part 5:
UNIT CONSTRUCTION
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 91 6th June 2011 / Rev.2
Fig 2 Fig 3
2.1 Simple Face This shows all the Seal Components
2.2 O-ring assembled in a Retainer to form the Seal
2.3 Spring Head Assembly.
To energise face and compensate for wear
2.4 Abutment Ring
To seat seal to working length
2.5 Combined Retainer
To drive face and to hold loose components
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 92 6th June 2011 / Rev.2
Part 6:
BALANCE
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 93 6th June 2011 / Rev.2
Fig 1
The first four items are normal process requirements where we have little or no influence.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 94 6th June 2011 / Rev.2
Factors involved and benefits obtained by reducing FACES STRESSESS.
Reduction of the closing forces is done to lower the face stresses at the running track.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 95 6th June 2011 / Rev.2
Axial Thrust
Axial Thrust in Single-Stage Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 96 6th June 2011 / Rev.2
Axial hydraulic thrust is the summation of unbalanced forces on an impeller
acting in the axial direction. As reliable large capacity thrust bearings are
now readily available, axial thrust in single-stage pumps remains a problem
only in a larger units. Theoretically, a double-suction impeller is in hydraulic
axial balance with the pressures on one side equal to an counterbalancing
the pressures.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 97 6th June 2011 / Rev.2
In practice this balance may not be achieved for the following reasons:
The suction passages to the two suction keys may not provide equal or
uniform to the two sides.
External conditions, such as an elbow located too close to the pump
suction nozzle, may cause unequal flow to the two suction eyes.
The two sides of the discharge casing waterways may not be
symmetrical or the impeller may be located off center. These conditions
will alter the flow characteristics between the impeller shrouds and the
casing, causing unequal pressures on the shrouds.
Unequal leakage through the two leakage joints can upset the balance.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 98 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 99 6th June 2011 / Rev.2
Combined, these factors can create axial unbalance. To compensate for this
all centrifugal pumps, even those with double-suction impellers, incorporate
thrust bearings.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 100 6th June 2011 / Rev.2
To eliminate the axial thrust of a single-suction impeller, a pump can be
provided with both front and back wearing rings; to equalize thrust areas, the
inner diameter of both rings is made the same.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 101 6th June 2011 / Rev.2
Axial forces acting on an overhung impeller with a single stuffing box are
definitely affected by suction pressure. In additional to the unbalanced force
found in a single-suction two-box design, there is an axial force equivalent to
the product of the shaft area through the stuffing box and the difference
between suction and atmospheric pressure. This force acts toward the
impeller suction when the suction pressure is less than atmospheric or in the
opposite direction when it is higher that atmospheric.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 102 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 103 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 104 6th June 2011 / Rev.2
Section 3
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 105 6th June 2011 / Rev.2
Overhung Impeller Centrifugal Pump
Configuration
What are the four sections of an overhung impeller centrifugal pump
configuration?
The four sections of an overhung impeller centrifugal pump consist of the
following:
Wet End
Power End
Driver
Baseplate and Foundation
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 106 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 107 6th June 2011 / Rev.2
The Power End Section
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 109 6th June 2011 / Rev.2
The Frame Adaptor
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 110 6th June 2011 / Rev.2
The Bearing Housing
The bearing housing provides a body in which the
bearings are mounted.
This housing, technicality, encompasses many of
the other components found within the power
end. The items listed below are often considered
part of the bearing housing when it is discussed.
However, each item is defined separately later in
the course.
Oil sump
Breather
Bearing protection
Snap ring
Oil sight glass
Deflector
Power end cooling jacket Bearing housing (highlighted without other
components)
Oil flinger
Thrust bearing cartridge
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 111 6th June 2011 / Rev.2
The Thrust Bearing Cartridge
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 112 6th June 2011 / Rev.2
The Pump Bearing
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 113 6th June 2011 / Rev.2
The Snap Ring
the snap ring maintains the positioning of the trust bearings to prohibits any axial
movement of the bearing inside the bearing housing or trust bearing cartridge.
The snap ring is installed into a groove that is machined into the housing or
cartridge. Sometimes the groove is machined in the outer race of the thrust
bearing.
A drawback with using a
snap ring in this location is
that the groove can become
worm and enlarged allowing
excessive axial movement.
This movement can cause
problems with the thrust
bearing and the mechanical
seal leading toward
premature failure. Snap ring
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 114 6th June 2011 / Rev.2
BEARINGS
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 115 6th June 2011 / Rev.2
The function of bearings in centrifugal pump is to keep the shaft or rotor in
correct alignment with the stationary parts under the action of radial and
transverse loads. Those that give radial positioning to the rotor are known as
line bearings, whereas those that locate the rotor axially are called thrust
bearings. In most applications the thrust bearings actually serve both as
thrust and radial bearings.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 116 6th June 2011 / Rev.2
Pump bearings may be rigid of self-aligning. A self-aligning bearing will
automatically adjust itself to a change in the angular position of the shaft. In
babbitted or sleeve bearings, the name self-aligning is applied to bearings
that have a spherical fit to sleeve in the housing. In antifriction bearings it is
applied to bearings the outer race of which is spherically ground or the
housing of which provides a spherical fit.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 117 6th June 2011 / Rev.2
The most common antifriction bearings used on centrifugal pumps are the
various types of bearings. Roller bearings are used less often, although the
spherical roller bearing is used frequently for large shafts sizes for which
there is a limited choice of ball bearings. As most roller bearings are suitable
only for radial loads, their use on centrifugal pumps tends to be limited to
applications in which they are not required to carry a combined radial and
thrust load.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 118 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 119 6th June 2011 / Rev.2
The thrust capacity of the bearing of a double-suction pump is usually far in
excess of the probable imbalance caused by irregularities. This provision is
made because:
Unequal wear of the rings and other parts may cause imbalance
The flow of the liquid into the two suction eyes may be unequal and
cause imbalance because of an improper suction-piping arrangement
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 120 6th June 2011 / Rev.2
Ball Bearings
As the coefficient of rolling friction is less than that of sliding friction, one
must not consider a ball bearing in the same light as a sleeve bearing. In the
former, the load is carried on a point contact of the ball with the race, but the
point of contact does not rub or slide over the race and no appreciable heat
is generated. Furthermore, the point of contact is constantly changing as the
ball rolls in the race, and the operation is practically frictionless. In the
sleeve bearing there is a constant rubbing of one surface over another, and
the friction must be reduced by the use of a lubricant.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 121 6th June 2011 / Rev.2
Ball thrust bearings are built to carry heavy loads by pure rolling motion
all the balls around the race, and the individual load on each balls is only
essential that the balls be very equally spaced, and for this purpose a
retaining cage is used between the balls and between the inner and outer
race. This cage carries no load, but the contact between it and the ball
this reason that the ball thrust bearings are generally water-jacketed.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 122 6th June 2011 / Rev.2
The most common ball bearings used on centrifugal pumps are:
Single-row, deep-grove
Double-row, deep grove
Double-row self-aligning
Angular-contact, either single or double-row
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 123 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 124 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 125 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 126 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 127 6th June 2011 / Rev.2
A bearing fully packed with grease prevents proper grease circulation in
itself and its housing. As a rough rule, therefore, it is recommended that only
one-third of the avoid spaces in the housing be filled. An excess amount of
grease will cause the bearing to heat up, and grease will flow out of the
seals to relieve the situation. Unless the excess grease can escape through
the seal or through the relief cock that is used on many large unit, the
bearings will probably fail early.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 128 6th June 2011 / Rev.2
Oil-lubricated ball bearings require an adequate method for maintaining a
suitable oil level in the housing. This level should be at about the center of
the lowermost ball of a stationary bearing. It may be achieved by a dam and
an oil slinger to maintain the level behind the dam and thereby increase the
leeway in the amount of oil the operator must keep in the housing. Oil rings
are sometimes used to supply oil to the bearings from the bearing housing
reservoir. In other designs, a constant-level boiler is used.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 129 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 130 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 131 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 132 6th June 2011 / Rev.2
The Face Seal
G. Excluder ring
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 133 6th June 2011 / Rev.2
Deflector
The deflector is a drive located on the
wet end side of the power end. The
purpose of the deflector is to keep
fluid from traveling down the shaft and
entering through the bearing
protection component, typically a lip
seal. the deflector is supposed to
deflect the fluid away from this
bearing protection device. Often, this
device provides little additional
protection for the bearings because it
fails to deflect anything.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 134 6th June 2011 / Rev.2
The Oil Sight Glass
The oil sump area
The oil sump area is where the oil is contained to provide lubrication and cooling for
the bearings. Sometimes grease is used instead of oil for bearings lubrication. In
this case the sump area is usually very small.
The oil sight glass
The oil sight glass is used to indicate the level and the
condition of the oil contained in the oil sump area.
The device comes in many forms. Two of the most
common found on pumps are Bulls-eye and tube
sight glasses.
A device that is often confused with the sight glass
is the constant-level or bulb type oilers found on
many pumps.
These devices are designed to provide additional
lubrication to the oil sump area in the event of an
Bulls-eye oil sight glass
oil leak through the bearing protection, usually a lip seal.
They provide no viewing of the level or condition of the oil found inside the pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 135 6th June 2011 / Rev.2
The Breather
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 136 6th June 2011 / Rev.2
Driver Parts
Overhung Impeller Centrifugal Pump
The Pump driver is the third section we will discuss. This Lesson will indentify
and describe the parts found in the driver section of an Overhung Impeller
Centrifugal Pump. A definition of the purpose of each part will also be given.
What are the parts in the driver section of an Overhung Impeller Centrifugal
pump?
The parts in the driver section can consist of the following:
Motor (Driver)
Coupling
Motor adapter
Belts
Gears
The Driver section need not contain all of the items listed above. As a minimum,
a driver (usually a motor) is required . The coupling, belts and gears are power
transmission devices that may or may not be required with the pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 6th June 2011 / Rev.2
Pump Drivers
The Motor
Energy is required to move the fluid.
Many types of drivers are used to
provide this energy. The motor is, by
far, the most common devices used to
drive pumps. It is an electrical
component that provides the input
energy ( power) being transferred
through the power end to the fluid
being pumped.
Motors come in a varying array of
types, sizes, enclosures and insulation
classes. However is the squirrel-
cage induction motor.
A typical squirrel-cage induction motor
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 6th June 2011 / Rev.2
Motor Adapter
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 6th June 2011 / Rev.2
Pump Coupling
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 140 6th June 2011 / Rev.2
Pump Coupling
The coupling
A coupling is a power transmission devices that is used to connect the motor
(driver) shaft to power end shaft of the pump. The primary purpose of the
coupling is to transmit rotary motion and torque from the motor to the pump.
Couplings often are required to perform other secondary functions as well. These
other functions include accommodating misalignment between shafts,
transmitting axial thrust loads from one machine to another, permitting
adjustment of shafts to compensate for wear and maintaining precise alignment
between connected shafts.
Many times pumps use couplings installed with a spacer. A spacer coupling
allows the pump to be disassembled without moving piping, the pump casing or
motor. A typical installation showing a spacer coupling is shown below.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 6th June 2011 / Rev.2
Pump Coupling
A coupling
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 142 6th June 2011 / Rev.2
Pump Spacer Coupling
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 143 6th June 2011 / Rev.2
Coupling Types Used in Pump Drive
Systems
A coupling is used wherever there is a need to connect a prime mover to a
piece of driven machinery. The principal purpose of coupling is to transmit
rotary motion and torque from one piece of equipment to another.
Couplings may perform other secondary functions, such as
accommodating misalignment between shafts, transmitting axial thrust
loads between machines, permitting adjustment of shafts to compensate
for wear, and maintaining precise alignment between connected shafts.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 144 6th June 2011 / Rev.2
Rigid Couplings
Rigid couplings are used to connect machines where it is desired to
maintain shaft I precise alignment. They are also used where the rotor of
one machine is used to support and position the other rotor in a drive
train. A coupling of this type cannot accommodate misalignment between
shafts, so precise alignment of machinery is necessary when using a
coupling of this design.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 145 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 146 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 147 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 148 6th June 2011 / Rev.2
Flexible Couplings
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 149 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 150 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 151 6th June 2011 / Rev.2
Overhung Impeller Centrifugal Pump
Support structure Parts and Function
The pump support structure is the fourth
What are the Parts in the support structure of an Overhung Impeller Centrifugal
pump?
The Parts in the support structure consist of the following:
Baseplate (Bedplate)
Foundation
Grouting
Jack-bolts
Shims
Not all of the above parts are required for the pump installation. Pumps are
usually mounted on the baseplate which , in turn, is mounted securely to the
foundation.
These two parts, along with the shims for alignment, are mot often the minimum
structure setup used. However, good installation and maintenance practices
grout the baseplates and provide jack-bolts for alignment.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 152 6th June 2011 / Rev.2
The Support Structure
Pump support structure showing foundation, baseplate, grout (in grout hole),
shims(under motor feet) and jack-bolts
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 153 6th June 2011 / Rev.2
Split Case Centrifugal Pump Part
Differences
Although we have focused mainly on the Overhung Impeller
Centrifugal pump, let's look at another common kinetic pump that is
found in industry. This other pump is an Impeller Between Bearing
pump or sometimes called Split Case pump. It operates similarly to
the Overhung Impeller pump, but has some distinct differences. This
lesson will describe the main differences between the Overhung
Impeller and Impeller Between Bearings Centrifugal Pumps.
Overhung Impeller and Impeller Between Bearings Centrifugal Pump
differences
The functions of the Overhung Impeller and Impeller Between
bearings Centrifugal pumps are primarily the same. Most of the
differences are a result of the mechanical design and configuration of
each pump type.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 154 6th June 2011 / Rev.2
Split Case Centrifugal Pump Part
Differences
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 155 6th June 2011 / Rev.2
Split Case Centrifugal Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 156 6th June 2011 / Rev.2
Multistage Pump
The split case design offers a large amount of flexibility when more than
one impeller is required. Because of this fact , most multiple stage (multi
impeller) pumps are designed and built using the Impeller Between
Bearings configuration.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 157 6th June 2011 / Rev.2
Multistage Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 158 6th June 2011 / Rev.2
Section 4
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 159 6th June 2011 / Rev.2
Centrifugal Pump Operation
Improper operation of centrifugal pump can result in damage to the
pump and loss of function of the system that the pump is installed in.
It is helpful to know what conditions can lead to pump damage to
allow better understanding of pump operation procedures and how the
procedures aid the operator in avoiding pump damage.
Define the following items
Pump terms
Net positive suction head
Cavitation
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 160 6th June 2011 / Rev.2
Pump Basic
DO YOU KNOW YOUR CENTRIFUGAL PUMP?
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 161 6th June 2011 / Rev.2
Pump Basic
In order to understand MECHANICAL SEALS
It is equally important to know something about the operating
of a Centrifugal Pump !
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 162 6th June 2011 / Rev.2
Pump Terms
As with any subject, there are essential terms that we must understand
without this knowledge of terms, it is very difficult to know pump
operation and system.
Pressure Terms:
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 163 6th June 2011 / Rev.2
Pump Terms
The Pressure :
Pressure is defined as a force acting over an area. Pressure, when
applied to a surface such as a fluid , acts in all directions equally.
Pressure will move through the path of least resistance. Pressure is often
expressed in pounds per square inch (psi or bar.
The atmospheric pressure:
Atmospheric pressure is the force exerted on an area by the weight of
the atmosphere. Atmospheric pressure will be different in Denver,
Colorado than it is in Miami , Florida.
The reason for this is due to the elevation with respect to sea level.
Places closer to sea level will have more of the atmosphere weighing
down on them and hence, more pressure. Atmospheric pressure at sea
level is defined as 14.69 ponds per square inch (psi) or 1.013 bar.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 164 6th June 2011 / Rev.2
The Absolute Pressure
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 165 6th June 2011 / Rev.2
The Gauge Pressure
Gauge pressure is the difference between a given fluid pressure and
that of the atmosphere. Gauge pressure is measured by a mechanical
or electrical device known as a pressure gauge.
Another way of stating gauge pressure is, the amount by which the
measured pressure is greater than atmospheric pressure.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 166 6th June 2011 / Rev.2
Absolute & Gauge Pressure
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 167 6th June 2011 / Rev.2
The Specific Gravity
Specific gravity is the density ratio of a liquid as compared to water at a
given temperature.
Water is used as the standard at 14.69 psia (1.013 bar abs) and at
60F (15.5 C). Its specific gravity is 1.0 at this standard temperature
and pressure. Because specific gravity is a ratio of the same property
(i.e., density), it has no units.
If a liquid has a specific gravity ratio greater than 1.0, it will sink in
water based on the standard. If a liquid has a specific gravity less than
1.0, it will float in water based on the standard.
Specific gravity of a liquid affects pressure relative to the height of the
liquid. The power requirement changes as specific gravity changes.
Common sense will tell you that the heavier a fluid is, more energy will
be required to pump it.
Specific gravity should not be confused with viscosity. Viscosity is a
measure of a liquids resistance to flow. Specific gravity and viscosity
are both properties of liquids, but there is no correlation between them.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 168 6th June 2011 / Rev.2
The Specific Gravity
Illustration of how liquids with different specific gravities and the same column
height produce different pressures at the bottom
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 169 6th June 2011 / Rev.2
The Capacity
Capacity is defined as the volume of liquid per unit time delivered by
the pump. It can also be described as the volumetric flowrate of the
fluid being transferred. The most common units for capacity are
usually gallons per minutes (GPM) or cubic meters per hour.
Centrifugal pumps do not offer a large amount of flexibility in capacity
variations without affecting the pump efficiency. Capacity is often
designated by the letter Q in current nomenclature.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 170 6th June 2011 / Rev.2
The Head
Head is a pump term often used to describe the mechanical energy
added to the fluid by centrifugal force. It is the quantity used to
express the energy content of the liquid per unit weight of the liquid.
Head is a good term to sue with centrifugal pumps because they are
constant energy devices. This means that for a given pump operating
at a certain speed and handling a definite fluid volume, the energy
transferred to this fluid (in foot Ibs. Per foot or Newtons per meter of
fluid) is the same for any fluid regardless of density.
The head generated by a given pump at a certain speed and capacity
will remain constant for all fluids, barring any viscosity effects.
Therefore, head when applied to centrifugal pumps is commonly
expressed in feet (or meters) of liquid. Head can also be used to
represent the vertical height in feet (or meters) of a static column of
liquid.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 171 6th June 2011 / Rev.2
The Head
Head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 172 6th June 2011 / Rev.2
Head vs Pressure
The Term Head is used to measure the kinetic energy created by the
pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 173 6th June 2011 / Rev.2
Head vs Pressure
The main reason for using head instead of pressure to measure a
centrifugal pumps energy is that the pressure from a pump will
change if the specific gravity (weight) of the liquid changes, but the
head will not change.
Since any given centrifugal pump can move a lot of different fluids,
with different specific gravities, it is simpler to discuss the pumps
head and forget about the pressure.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 174 6th June 2011 / Rev.2
Pumping System Characteristics
Static Head Consists of :
Static suction head (hS): lifting liquid relative to pump center line.
Static discharge head (hD) vertical distance between centerline and
liquid surface in destination tank.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 175 6th June 2011 / Rev.2
Pump Curves
We know how fluid flows into and out of a pump & How a pump
converts energy to make it move. Pump will perform according to their
pump head-capacity performance curves.
It use and define how operating condition changes affect this curve.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 176 6th June 2011 / Rev.2
Single Pump Performance Curve
A Pump head capacity performance curve, or pump curve, is
determined from actual pump performance data in a laboratory. This
curve is a plot of a pumps ability to generate fluid flow (capacity)
against a certain head. Every pump, regardless of the manufacturer
has its own unique curve.
A Pump takes mechanical energy from a motor and transforms it to
velocity energy at the impeller vanes. The pump casing then changes
the velocity energy to a pressure energy at the pump discharge.
This pressure energy dissipates as the fluid moves through a system
(i. e., pressure drop).
The pumps head capacity curve defines how much energy is
available at a given flow rate, impeller diameter and shaft speed for
each pump size.
This pump curve is often called a Single Pump Performance Curve.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 177 6th June 2011 / Rev.2
Pumps
The Head and capacity are the main factors, which affect
the horsepower size of the motor to be used.
Head Impeller diameter, number of impellers, size of
impeller eye & shaft speed.
Capacity exit width of the impeller.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 178 6th June 2011 / Rev.2
Pump Basics
BEP point of bests eff.
Pump efficiency
Head
m|c /
eff. /
power
power
KW
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 180 6th June 2011 / Rev.2
The Static Head
Static Head is defined as the distance measured vertically above or
below an arbitrarily selected horizontal datum level. In a simple
pumping system the horizontal datum level is usually the pump
centerline (q).
In a pumping system, this head represents the energy required to
raise the liquid from the pump centerline to the point in the pipe that
the liquid needs to be raised.
This energy will vary with specific gravity as the pressure energy
needed to raise the liquid will increase with increasing specific gravity.
Static head consists of two parts: Sustion static head and Discharge
static head. The difference between these two is called total static
head or sometimes just static head.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 181 6th June 2011 / Rev.2
Static suction Head (hs)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 182 6th June 2011 / Rev.2
Static suction Head (hs)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 183 6th June 2011 / Rev.2
Static Discharge Head (hD)
Discharge static head as measured from the centerline of open pipe above the discharge tank
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 184 6th June 2011 / Rev.2
Static Discharge Head (hD)
Discharge static head as measured to the level of the liquid surface in the discharge tank
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 185 6th June 2011 / Rev.2
The Static Head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 186 6th June 2011 / Rev.2
Static Head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 187 6th June 2011 / Rev.2
System With Low Static Head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 188 6th June 2011 / Rev.2
System With Low Static Head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 189 6th June 2011 / Rev.2
Dynamic (Friction) head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 190 6th June 2011 / Rev.2
A Simple Pumping System
Pumps are never installed without piping, they are always a part of a
pumping System.
If not properly designed, the system can cause the pump to fail, or at
least , cause it to perform poorly.
A pump operates as part of system, and pumping system as
mechanical Components.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 191 6th June 2011 / Rev.2
Pump Basics
Pump Head Discharge or
Head Capacity Curve is
generated from a test on the
Head pump at the pump
manufacturer's shop.
Discharge / Capacity
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 192 6th June 2011 / Rev.2
Pumping System
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 193 6th June 2011 / Rev.2
Pump Basics
The System curve is
based on the pipes and
fittings in the pump
Head circuit at site.
This is normally
provided by the
Engineering Cont. or
Consulting Engg. At the
project stage.
Discharge / Capacity
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 194 6th June 2011 / Rev.2
Pump Basics
System Characteristics
Pump
Head
head
mlc System
Curve
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 196 6th June 2011 / Rev.2
AFFINITY LAWS
AFFINITY LAWS CENTRIFUGAL PUMPS
If the speed or impeller diameter of a pump change, we can calculate the
resulting performance change using:
Affinity laws:
1. The flow changes in proportion to speed.
ie: double the speed / double the flow
2. The pressure chnages by the square of the difference.
ie: double the speed / multiply the pressure by 4
3. The Power changes by the cube of the difference.
ie: double the speed / multiply the power by 8
Notes:
1. These laws apply to operating points at the same efficiency.
2. Variations in impeller diameter greater than 10% are hard to predict
due to the change in relationship between the impeller and the
casing.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 197 6th June 2011 / Rev.2
Net Positive Suction Head
Net Positive suction head is the term that is usually used to describe the absolute
pressure of a fluid at the inlet to a pump minus the vapor pressure of the liquid.
The resultant value is known as the Net Positive Suction Head available.
The term is normally shortened to the acronym NPSHa, the a denotes available
A similar term is used by pump manufacturers to describe the energy losses that
occur within many pumps as the fluid volume is allowed to expand within the pump
body.
This energy loss is expressed as a head of fluid and is described as NPSHr (Net
Positive Head Suction Head requirement) the r suffix is used to denote the value is
a requirement.
Different pumps will have different NPSH requirements dependant on the impellor
design, impellor diameter, inlet type, flow rate, pump speed and other factors.
A pump performance curve will usually include a NPSH requirement graph
expressed in metres or feet head so that the NPSHr for the operating condition can
be established.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 198 6th June 2011 / Rev.2
NPSH
Pressure at the pump inlet
The fluid pressure at pump inlet will be determined by pressure on the fluid surface, the
frictional losses in the suction pipework and any rises or falls within the suction pipe
system.
NPSHa calculation
The element used to calculate NPSHa are all expressed in absolute head units.
The NPSHa is calculated from:
Fluid surface pressure + positive head pipework friction loss-fluid vapour pressure
Or
Fluid surface pressure + negative head pipework friction loss-fluid vapour pressure
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 199 6th June 2011 / Rev.2
Net Positive Suction Head
Net Positive Suction Head NPSH
The difference between the actual pressure of the fluid at the pump
inlet and the vapour pressure of that fluid.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 200 6th June 2011 / Rev.2
Net Positive Suction Head
Vapor Pressure
If the ambient pressure is greater than the vapor pressure then the vapor is
contained within the liquid
If the ambient pressure is less than the vapor pressure, then the vapor is
released the liquid boils.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 201 6th June 2011 / Rev.2
Net Positive Suction Head
saturated vapor pressure of water
100
50
(oC)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 202 6th June 2011 / Rev.2
Net Positive Suction Head
Static
Head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 203 6th June 2011 / Rev.2
NPSH
Net Positive Suction Head
Available (NPSHA)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 204 6th June 2011 / Rev.2
Net Positive Suction Head
Net Positive Suction Head Required (NPSHR)
As shown below, the pressure drops to a minimum level at the impeller eye
before the liquid is acted upon by the impeller vanes. It is the minimum value
that is determined by testing and given the name Net Positive Suction Head
Required (NPSHR).
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 205 6th June 2011 / Rev.2
Net Positive Suction Head
The NPSHr increases with flow due to pump internal losses friction,
impeller losses etc.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 206 6th June 2011 / Rev.2
Net Positive Suction Head (NPSH)
Net Positive Suction Head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 207 6th June 2011 / Rev.2
Centrifugal Pump Characteristics
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 208 6th June 2011 / Rev.2
Pumping System Characteristics
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 209 6th June 2011 / Rev.2
Net Positive Suction Head
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 210 6th June 2011 / Rev.2
Section 5
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 211 6th June 2011 / Rev.2
Cavitation
Gas Bubbles within the fluid (cavitation)
The Vapor pressure of a fluid is the pressure at which the fluid will boil
at ambient temperature. If the pressure within a fluid falls below the
vapor pressure of the fluid, gas bubbles will form within the fluid (local
boiling of the fluid will occur).
To avoid cavitation the pressure within the fluid must be higher than the
fluid vapor pressure at all times.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 212 6th June 2011 / Rev.2
Cavitation in Centrifugal Pump
Classic Cavitation
Cavitation means many things to many people. It is also can come in a variety of forms.
The most common type is Vaporization Cavitation or Classic Cavitation.
This lesson will discribe the causes of Classic Cavitation and how it can be reduced or
eliminated
The effect of classic or Vaporization Cavitation on Pump Mechanical
Operation
Vaporization cavitation will also affect pump mechanical operation. The result of this
cavitation is sometimes severe mechanical damage. This damage usually occurs on the
impeller, but it is sometimes found on the volute. The extent of this damage depends on
the severity of the cavitation and the hardness of the impeller and volute materials.
When bubbles of vapor implode on a metal surface they do so in such a way a s to form a
toroidal shape as shown in Figure 1. This shape creates pressures in excess of 150,000
psi (10,000 bar). No known materials can withstand this type of punishment. The damage
will begin near the impeller eye and continue along the trailing edge of the impeller vanes
as shown in Figure-2.
The collapse of these bubbles creates extreme noise and vibration. This vibration can, and
often does, cause other mechanical damage to the bearings or mechanical seal. Reduced
pump reliability is the ultimate result.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 213 6th June 2011 / Rev.2
Cavitation in Centrifugal Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 214 6th June 2011 / Rev.2
Cavitation
Comparison of NPSHa AND NPSHr
All calculated values must be in the same units either m hd or ft hd.
If the NPSHa is greater that the NPSHr cavitation should no occur.
If the NPSHr is lower that the NPSHr then gas bubbles will form in the fluid and
cavitation will occur.
Increasing the NPSH available
Many system suffer from initial design consideration.
To increase the NPSHa consider the following:
a. Increase the suction pipe work size to give a fluid velocity of about 1
m/sec or 3 ft/sec.
b. Redesign the suction pipe work to eliminate bends, valves and
fittings where possible
c. Raise the height of the fluid container.
d. Pressurise the fluid container, but ensure thet the pressure in the
container is maintained as the fluid level is lowered.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 215 6th June 2011 / Rev.2
Result of Cavitation
Noise
Vibration
Damage to pump and piping
Reduced Flow.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 216 6th June 2011 / Rev.2
NET POSITIVE SUCTION HEAD TROUBLES
AND
HOW TO AVOID THEM
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 217 6th June 2011 / Rev.2
(P-P v) X 2.31
Npsha = - Ha z
spgr
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 218 6th June 2011 / Rev.2
How can npsh get you into trouble?
Well assume your pump was properly applied when you originally brought
it. But now there are subtle signs of cavitation: the pump sounds as if
its pumping marbles; the impeller seems to have had a bad case of small
pox. What has happened? There are four major possibilities; lets look at
them one by one.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 219 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 220 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 221 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 222 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 223 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 224 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 225 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 226 6th June 2011 / Rev.2
Cavitations in centrifugal pumps
How to avoid cavitations
As cavitations relates only to the suction side of the pump all presentation
measures should be directed at this area.
Suction lifts that are too high will only encourage cavitations. As a
general rule, centrifugal pumps located less than 4 meters above the water
level should not experience cavitations.
The following guidelines should be applied to avoid the problem:
- minimize the number of valves and bends in the suction line.
- use eccentric reducers, not concentric.
- ensure the straight side of the eccentric reducer is installed along the top of
the suction line.
- Suction length should be as short as possible.
- Suction pipe should be at least the same diameter as the pump inlet
connection.
- use long radius bends.
- increase the size of valves and pipe work.
- do not allow air into the suction line.
- ensure adequate submergence over the foot valve. The submergence
should be at least 5.3 times the suction diameter.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 227 6th June 2011 / Rev.2
Concentric Eccentric
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 228 6th June 2011 / Rev.2
Cavitation
The purpose of an eccentric reducer is to transition the
pipe sizes from a larger incoming supply to a smaller
suction inlet on the pump. Eccentric reducers are easily
identified by the fact that one side appears to be flat,
while the other side is tapered toward the suction inlet.
When the pump is fed from below or the side from an
underground water main, the eccentric reducer must be
installed with the flat side on the top, parallel to the
floor. This arrangement prevents air being trapped in
the upper portion of the fitting. Air entering the suction
side of the pump can cause dangerous cavitations.
In those configurations where the fire pump supply
comes from above, such as is the lower elevations of a
basement or from an elevated tank, the eccentric
reducer may be installed with flat side down, parallel
to the floor. When the water supply is delivered from
above, any trapped air can be bled off at the top of the
pump casing while the system is filled with water. In
todays illustration, the water supply is on the right-hand
side of the picture, and is entering the pump from
above. Therefore, it is described as a top-feed
installation and the reducer may be installed as it is
shown.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 229 6th June 2011 / Rev.2
(Flow coming from below)
Figure 1 Eccentric at the pump suction (source: the pump handbook published by McGraw-Hill)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 230 6th June 2011 / Rev.2
Principles of Operation
Centrifugal force
Based on the principle that a rapidly revolving
impeller hurls the water from the impeller eye
outward.
The faster the impeller is turned, the farther the
water us thrown increasing the velocity.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 231 6th June 2011 / Rev.2
Influencing Factors
Amount of water being discharged
Speed at which the impeller is turning
- Doubling the speed results in four times the
pressure.
Pressure of water when it enters the pump from a
pressurizes source.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 232 6th June 2011 / Rev.2
Operation
Starting the Pump
Ensure that the pump is correctly installed:
If the pump has a flush seal option, start the flow of flush water
(recommended rate is approximately 5 US gallons per hour) before operating
the pump.
Before starting the pump, prime the pump by flooding the pump casing with
liquid to avoid damaging the pump parts. Depending on the installation, refer
to either:
- Priming the Pump with the Feed Source above Pump Level.
- Priming the Pump with the Feed Source Below Pump level.
Start the pump motor.
Check the pump to ensure that the liquid is flowing and that all piping
connections and seals are leak-free.
Make sure that the pump is not operating against a closed discharge.
Continued operation against a closed discharge will heat the liquid in the
casing to boiling and lead to pump damage.
Slowly open the discharge valve until the desired flow is obtained. Observe
the pressure gauges. If pressure is not attained quickly, stop the pump and
prime it again.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 233 6th June 2011 / Rev.2
Operation
Priming the Pump
Priming the Pump with the Feed
Source above Pump Level:
Fill the supply tank with liquid
and open the supply line
(suction) valve (see the Figure,
item B).
Open the discharge valve to
vent any air trapped in the
supply line or casing (see the
Figure, Item A).
Resume the Starting the
Pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 234 6th June 2011 / Rev.2
Operation
Priming the Pump
Priming the Pump with the Feed
Source above Pump Level:
The pump will not self-prime if the liquid
supply is below the pump level. If the
liquid supply is below the pump level,
provide an outside source for priming.
Close the discharge valve (see the
Figure, item C) and open the air vents.
Open the valve in the outside supply line
(see the Figure, item A) until liquid fows
from the vent valves.
Close the vent valves.
Close the outside supply line.
Note: use a type of check valve system
(see the Figure Item B) to keep the
supply line and pump casing flooded with
liquid otherwise the pump must be
primed before each operation.
Resume the Starting the Pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 235 6th June 2011 / Rev.2
Operation
Stopping the Pump
To Stop the pump, shut off power to the pump motor.
Note: Liquid in the system can flow freely through the pump; the pump
does not act as a shutoff valve.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 236 6th June 2011 / Rev.2
How to operate Centrifugal pump,
working principle and type
Standard operating procedure to operate centrifugal pump is:
Suction Valve of the pump to be opened which cause fluid flow to the impeller
and fill the volute of the centrifugal pump.
Open the vent valve which is on the discharge line before the discharge valve
of the centrifugal pump which cause all air to move out of the casing and filled
with pumping fluid only.
When some quantity of the fluid comes out from the vent valve close the
valve.
Now open the bypass valve of the discharge valve which is near or side of the
discharge valve on discharge line.
Now start the pump and let it attain its capacity in the pressure gauge on the
discharge line.
When the pressure gauge is stable it is time to open that discharge valve of
the centrifugal pump.
These steps are considered as standard operating procedure for most of the
centrifugal pumps in chemical industries.
Note: Check periodical maintenance log book to confirm about cleaning of the
strainer in the suction line and fitted back, to protect the impeller from
damage.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 237 6th June 2011 / Rev.2
Operation
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 238 6th June 2011 / Rev.2
Operation
Cleaning-In-Place (CIP)
Make Certain that all connections in the cleaning circuit are properly applied
and tightened to avoid contact with hot water or cleaning solutions.
When the cleaning cycle is controlled from a remote or automated cleaning
center, establish safe procedures to avoid automatic start-up while servicing
equipment in the circuit.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 239 6th June 2011 / Rev.2
Pump Basics
Pump Operation:
Single pump
pumps running in parallel
pumps running in series
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 240 6th June 2011 / Rev.2
SERIES AND PARALLEL OPERATION
OF CENTRIFUGAL PUMPS
A centrifugal pump will pump fluid at the point where the system curve
intersects the pump curve.
If you need more flexibility you can install another pump and operate
it in either series or parallel with the first pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 241 6th June 2011 / Rev.2
SERIES OPERATION
Centrifugal pumps are connected in series if the discharge of one
pump is connected to the suction side of a second pump. Two similar
pumps, in series, operate in the same manner as a two-stage
centrifugal pump.
Each of the pumps is putting energy into the pumping fluid, so the
resultant head is the sum of the individual heads.
Some things to consider when you connect pumps in series:
Both pumps must have the same width impeller or the difference in
capacities (GPM or Cubic meters/hour.) Could cause a cavitations
problem if the first pump cannot supply enough liquid to the second
pump.
Both pumps must run at the same speed ( same reason).
Be sure the casing of the second pump is strong enough to resist the
higher pressure. Higher strength material, ribbing, or extra bolting may
be required.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 242 6th June 2011 / Rev.2
SERIES OPERATION
The stuffing box of the second pump will see the discharge pressure
of the first pump. You may need a high- pressure mechanical seal.
Be sure both pumps are filled with liquid during start up and
operation.
Start the second pump after the first pump is running.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 243 6th June 2011 / Rev.2
The basics of Parallel & Series
Operation of Pump
Parallel & Series Operation
The use of two or more pumps to increase flowrate is called Parallel pumping. The
use of two or more pumps to increase head(pressure) is called Series pumping.
Operation of pumps under these circumstances may appear simple, but these are
more complex issues to consider, ie:
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 244 6th June 2011 / Rev.2
The basics of Parallel & Series
Operation of Pump (Pressure)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 245 6th June 2011 / Rev.2
Parallel Operation
Pumps are operated in parallel when two or more pumps
are connected to a common discharge line, and share the
same suction conditions.
Some things to consider when pumps are operated in
parallel:
Both pumps must produce the same head this usually
means they must be running at the same speed, with the
same diameter impeller.
API 610, states that when pumps are run in parallel, the
head shall rise at least 10% of the head at rated capacity.
(this is called a stable curve because there is a
continuous rise to shutoff).
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 246 6th June 2011 / Rev.2
The basics of Parallel & Series
Operation of Pump
In parallel applications: confirm suitability of pumps by drawing a system curve (often
2 pumps will only deliver slightly more than one pump due to excessive friction loss.
also you can confirm that pump operation will be with in its recommended range.).
Non return values are required especially if one pump operates alone at times.
Dissimilar pumps or pumps placed at different heights requires special investigation.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 248 6th June 2011 / Rev.2
Pump Basics
Pump op point /
Head parallel operation
Pump op point /
single bump running
Discharge
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 249 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 250 6th June 2011 / Rev.2
Parallel & Series Operation
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 251 6th June 2011 / Rev.2
Section 6
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 252 6th June 2011 / Rev.2
Trouble Shooting
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 253 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 254 6th June 2011 / Rev.2
Pump trouble shooting centrifugal
pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 255 6th June 2011 / Rev.2
Trouble Shooting
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 256 6th June 2011 / Rev.2
PUMP OPERATION PROBLEM
SOLVING
General
Truth
The Great Majority of Pump Problems are with the Pump System.
The Majority of Pump System Problems are on the Suction Side.
Pump Problems are usually associated with Noisy Operation.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 257 6th June 2011 / Rev.2
Insufficient Pressure
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 258 6th June 2011 / Rev.2
No Liquid Delivered
Pump suction broken (water level bellow inlet)
Suction valve closed
Impeller plugged
Strainer clogged
Wrong rotation
Shaft broken or unscrewed
Impeller loose
Barallel or discharge not vented
Driver incorporate
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 259 6th June 2011 / Rev.2
Vibration
Motor imbalance electrical
Motor bearing not properly seated or worn
Motor drive coupling out of the balance or alignment
Misalignment of pump, casings, discharge head column, or bowies.
Discharge head misaligned by improper mounting or pipe strain
Bent shafting
Worn pump bearings
Clogged impeller or foreign material in pump
Improper impeller adjustment
Vertex problems in sump
Resonance system frequency at or near pump speed
Cavitation
Impeller out of balance
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 260 6th June 2011 / Rev.2
Insufficient Capacity
Speed to slow
Impeller trimmed incorrectly
Impeller loose
Impeller or bowl partially plugged
Leaking joints
Strainer or suction pipe clogged
Suction valve throttle
Low water level
Wrong rotation
Insufficient submergence
Insufficient N.P.S.H.
Incorrect impeller adjustment
Worm pump
System pressure higher than design
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 261 6th June 2011 / Rev.2
Abnormal Nose
Motor noise
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 262 6th June 2011 / Rev.2
Problem Solving Components
SHAFT & COUPLING
Trouble Source Probable Cause Remedy
Bent Shaft Mishading in transits or assembly. Check straightness.
Correct to 0.0005ft total rubnover
or replace
Shaft Coupling unscrewed Pump started in reserve rotation Shaft may be bent check shafts &
couplings.
Correct rotation
Shaft coupling Motor started while pump running in Look for faulty check valve.
elongated (necked reverse. Could also be momentary
down) Corrosion power failure or improper
Pipe wrench fatigue on reused starting
couplings timers.
Power being applied to shafts that are Replace couplings
not butted in coupling. Check for galling on shaft ends.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 263 6th June 2011 / Rev.2
Problem Solving Components
SHAFT & COUPLING
Trouble Source Probable Cause Remedy
Broken shaft or Can be caused by same reasons Same as above
coupling listed for coupling elongation. Same as above for bearing
Can also be caused by bearings seizure
seized due to lack of fabrication Add strainers or screens
Foreign material locking impellers Check alignment of pump
or galling wear rings. components to eliminate
Material locking impellers or vibration
galling wear rings. Metal fatigue See sections on impeller
due to vibrations. adjustment and upthrusting.
Improper impeller adjustment or
continuous upthrust conditions,
causing impeller to drag.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 264 6th June 2011 / Rev.2
Problem Solving Components
BOWLS
Trouble Source Probable Cause Remedy
Wear and bowel vanes Abrasive Cost Bowls, upgrade material
or rubber line
Bell suction vanes. Cavitation Correct condition or upgrade
Wear on suction bell vanes material to extend life
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 265 6th June 2011 / Rev.2
Problem Solving Components
STUFFING BOX
Trouble Source Probable Cause Remedy
Excessive leakage Improper packing procedures Repack correctly. See suction on packing.
Incorrect type of detective packing Repack with correct grade for service.
Stuffing box overheating Improper packing products Repack correctly. See suction on packing.
Packing too tight Released gland pressure.
Packing wear promptly Improper packing procedures Repack correctly. See suction on packing.
Insufficient lubrication Repack correctly.
Incorrect type of detective packing Repack with correct grade for service.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 266 6th June 2011 / Rev.2
Problem Solving Components
INNER COLUMN
Trouble Source Probable Cause Remedy
Water in inner column Bypass parts plugged Remove causes
Badly worn bypass seal or Replace worn parts
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 267 6th June 2011 / Rev.2
Problem Solving Components
IMPELLERS
Trouble Source Probable Cause Remedy
Wear and bowel vanes Abrasive action Replace impeller if excessive.
Consider coating or
upgrading materials
Pitting on entrance vanes Cavitation Correct condition or upgrade
of impeller material to oxidized life.
See section on Cavitation.
Pitting on impellers and Corrosion / Errosion Investigate cost of different materials
bowl casting vs frequency of replacements.
See section on corrosion.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 268 6th June 2011 / Rev.2
Problem Solving Components
IMPELLERS
Trouble Source Probable Cause Remedy
Wear on impeller skirts Abrasive action wear Install new bearings and wear rings.
and/or bowl sealing areas allowing impeller skirts to Upgrade material if abrasive action
function as bearing journal. Re-ring & adjust impellers correctly.
Impellers set too high
Impeller and seal wear Improper impeller djustment. Install L shaped bowl wear rings.
Impeller running on bottom Adjust impeller setting per
manufacturer recommendation.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 269 6th June 2011 / Rev.2
Problem Solving Components
IMPELLERS
Trouble Source Probable Cause Remedy
Impeller loose on shaft Repeated shock load by surge Re-fit impellers. If collect
(extremely loose on in suction or discharge line (can mounted, consider changing to
shaft, extremely rare loosen first or last stage key mounting.
occurance) impellers) Remove cause of jamming.
Foreign material jamming If collect mounted, consider
impeller (may break shaft or trip changing to key mounted. Avoid
overloads before impeller sudden thermal shock.
becomes loose) Correct parts if necessary and
Differential expansion due to re-fit.
temperature Add key way to collect
Parts improperly machined mounting.
and/or assembled.
Torsion loading on submersible
pumps.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 270 6th June 2011 / Rev.2
Problem Solving Components
BEARINGS
Trouble Source Probable Cause Remedy
Bearing failure or High temperature failure Check pump manufacturer for bearing
bearing seized temperature limits. General
temperature limits shown on page.
Excessive shaft wear Rubber bearings will swell Change bearing material
under rubber bearings in hydrocarbon. H2S & HI
temperature
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 271 6th June 2011 / Rev.2
Problem Solving Components
BEARINGS
Trouble Source Probable Cause Remedy
Uneven wear on Pump non rotating parts Check mounting & discharge pipe
bearing, uniform wear on misaligned connection, dirt between column
shaft joints.
Correct misalignment, replace
bearings & repair or replace shaft.
Uniform wear on Abrasive action Replace parts, consider changing
bearing and shaft materials or means of lubrication.
Uniform wear on Shaft run out caused by Straighten shaft or replace, clean &
bearings, uneven wear bent shafts, shafts not assemble correctly.
on shaft butted in couplings, dirt or Face parallel and concentric
grease between shafts.
Shaft ends not properly
faced.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 272 6th June 2011 / Rev.2
Bearing Failure
Bearing Failure
Bearing Failure is on the most common pump
failures found in industry. Assuming the bearing is
properly sized and installed, the most common
cause of bearing failure is lubrication
contamination. This lesson will identify ways to
reduce lubrication contamination using various
methods of bearing protection.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 274 6th June 2011 / Rev.2
Lip Seals
Lip seals are positive contact rubbing seals Another limitation with lip seals is that they fret
that are located on the pump power end. Lip or groove the shaft over time. This fretting
seals contact the rotating pump shaft. damages the shaft. When worn lip seals are
These seals are designed to allow a very replaced with new seals, they will not seal
small amount of leakage. The leakage acts properly on a damaged shaft.
as a lubricant for the lip seal contact area. The shaft often has to be repaired or replaced.
The illustration below shows a shaft damaged
Lip seals have some very limiting by a lift seal.
drawbacks. The majority of these seals
have a small finite life span. This averages
out to be 2 4 months on most pumps.
Another problem with lip seals is that they
fret or groove the shaft over time. This
fretting allows oil leakage out and
contaminants into the pump, not to mention
the damage it does to the shaft.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 275 6th June 2011 / Rev.2
Lip Seals
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 276 6th June 2011 / Rev.2
CENTRIFUGAL PUMP CLINIC
Visual examination of pumps.
Net positive suction head troubles- and how to avoid them.
Trouble shooting of centrifugal pumps.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 277 6th June 2011 / Rev.2
VIBRATION
Excessive vibration can lead to sudden and catastrophic failure in a
pump
when a sufficient number of vibration cycles occur, exceeding a given
components material fatigue level.
Vibration levels should be carefully monitored during pump operation.
Levels
which are outside of the pump manufacturers limits should be
investigated as
soon as possible. General causes of excessive vibration are rotating
element
imbalance, and worn or loose parts or misalignment.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 278 6th June 2011 / Rev.2
PUMP NOISE
Pump noise is not a destructive in itself, but it can be an indication of
operation away from the design point, an intake flow disturbance or
cavitation.
Cavitation noise occurs when a system pressure adjacent to a flow
bounday is
reduced below the vapor pressure of the liquid. The net result is that
voids
are formed in the fluid which can travel with the flow and collapses as
they
encounter higher pressure areas.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 279 6th June 2011 / Rev.2
CAVITATION
The cavitation process in a liquid can be described as a gas or gasvapor
filled bubble which collapses or implodes when the vapors condense and
the gas goes into solution. Cavitation begins with the bubble formation
and extends through the cavity collapse. This collapse produces enough
energy to erode even the most durable metals used in a pump.
Cavitation pitting typically occurs on or near the pump impeller. Severe
Cavitation may exhibit itself as small holes in the metal. These holes
create additional under pressure areas and the Cavitation damage may
continue at an accelerating rate in areas of large material loss.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 280 6th June 2011 / Rev.2
Cavitation can be manifested by one or more of the following
signs:
Noise and Vibration
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 281 6th June 2011 / Rev.2
Factors which affect the suction requirements of the pump are
Impeller eye diameter
Suction area of impeller
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 282 6th June 2011 / Rev.2
TO GUARD AGAINST
CENTRIFUGAL-PUMP FAILURES,
KNOW
THEIR PRIMARY CAUSES
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 283 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 284 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 285 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 286 6th June 2011 / Rev.2
Section 7
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 287 6th June 2011 / Rev.2
Basic maintenance
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 288 6th June 2011 / Rev.2
Pump Maintenance
The efficiency of pump units relates directly to dollars. Either dollars into
your pocket or out of it. The Correct selection, operation and
maintenance of pump units is essential if maximum efficiency and
operational life is to be achieved. Pump units not operated on their most
efficient points suffer from extra mechanical damage through additional
stress being applied and in some cases cavitations damage to impellers
and pump parts. The cost per kilolitre of water pumped is increased and
correct coverage or application rates from sprinklers may not be
achieved resulting in crop loss. The efficiency of pump units can be
maintained and in some cases increased by employing modern overhaul
methods, the use of mechanical seals and internal glazing.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 289 6th June 2011 / Rev.2
Pump Maintenance
Why perform Maintenance?
Maintenance of mechanical and electrical plant is essential if equipment is to
remain in a safe and reliable condition and perform the duty it was designed
to do and in a cost effective manner.
We maintain equipment to ensure:
Reliability
Efficiency
Extend the assets service life.
Maintenance levels vary depending on the complexity of equipment and the
consequence of failure. We must ensure our pumps and motors are
maintained in a safe and reliable condition. The level of maintenance and
expenditure can be evaluated by considering the cost of failure.
Evaluate the risk to personal safety and environment damage.
Crop loss
Cost of emergency arrangements
Cost of emergency repairs
Total cost of asset
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 290 6th June 2011 / Rev.2
Pump Maintenance
What type of maintenance is applicable for a block pump?
Maintenance can be performed by having procedures based on :
Reactive Maintenance:
Maintenance is performed only when it has failed and you are required to
act immediately.
This form of maintenance can be supported by spare or in some cases a
spare pump so that down time is kept to a minimum.
Reactive Maintenance is not a good method.
Preventative Maintenance:
This form of maintenance required you to act just prior to failure.
Deciding on what has to be performed and when is it a major problem.
Predictive Maintenance:
By recording selected readings, not operational conditions you can try to
predict when the unit may fail and of course act prior to this point being
reached.
Predictive maintenance is the best method.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 291 6th June 2011 / Rev.2
Important Safety Precautions
Pump parts, tools, and rigging equipment used in installing pumps are heavy and may easily
cause personal injury if dropped or carelessly handled. The normal precautions and safety rules
associated with the erection of heavy machinery, use of power equipment, manual lifting, and
handling of tools must be observed in the installation of this pump.
Do not work under a heavy suspended object unless there is a positive support under it to stop
its fall in event of sling or hoist failure. Disregard of this warning could result in grave injury.
Before opening the conduit box of an electric motor, be certain that the current to the motor is
shut off and the breakers are locked out. An electrical shock from contact with live motor leads
can be fatal.
The motor canopy (cover) must be in place when the pump is in operation. If exposed, rotating
parts below this cover could cause grave personal injury.
Petroleum-based cleaning solvents are flammable. Smoking by personal in the vicinity of these
solvents is extremely hazardous and must not be permitted. Also, in many areas, the use of
these contaminating and hazardous solvents is illegal. Consult the local EPA/Air Quality officials
for instructions.
The pumps described in this manual should not be installed in any
manner except as specified herein, and must not be operated at
speeds, capacities, pressures, or temperatures other than those
specified on this order.
These pumps must not be used to pump any fluid other than those
specified for the order.
Violation of this warning will void the manufacturers warranty and
may result in serious property damage or grave personal injury.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 292 6th June 2011 / Rev.2
Pump Maintenance
There are other preventative maintenance programs such as
Continuous Diagnostic Maintenance which takes constant readings
and notes any significant change in the readings. Machine history is
also a good tool to predict the life of a pump. It is based upon like
operation in that it relies upon the history of the previous unit relating
to the present unit. Since the taking of readings and observations
form a vital part of most maintenance programs what should be
looked for?
Heat in bearings and glands.
Pressure pump discharge pressure.
Noise Cavitations, bearings.
Flow a drop off in Flow.
Leakage glands piping oil or grease.
Power consumption
Vibration an increase could indicate problems.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 293 6th June 2011 / Rev.2
Important Safety Precautions
Making your Pump Last
The Following check list may aid you in keeping your pumps in top condition.
Check the following points on a monthly basis:
Priming speed
Capacity
Noise in pump casing
Gaskets and O-rings.
Shaft seal leakage of air and water.
Hose, hose washers and suction strainer.
Crankcase oil level (engine).
Spark plug condition (engine).
Air cleaner (engine).
Unusual engine noise.
Proper RPM (engine).
Carburetor adjustment (engine).
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 294 6th June 2011 / Rev.2
Important Safety Precautions
The Following check list may aid you in keeping your pumps in top
condition.
Check the following points every 6 months:
Impeller wear
clearance between impeller face and the volute (refer to
manufacturers recommendations)
Shaft seal wear.
Shaft sleeve wear.
Clean the casing and volute passages.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 295 6th June 2011 / Rev.2
Two Types of Maintenance
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 296 6th June 2011 / Rev.2
Maintenance Strategies
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 297 6th June 2011 / Rev.2
Maintenance Strategies
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 298 6th June 2011 / Rev.2
Maintenance Strategies
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 299 6th June 2011 / Rev.2
Maintenance Strategies
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 300 6th June 2011 / Rev.2
VIBRATION MONITORING AND
ANALYSIS
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 301 6th June 2011 / Rev.2
Vibration Measurements
Bearing vibration
Shaft vibration
Relative shaft vibration
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 302 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 303 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 304 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 305 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 306 6th June 2011 / Rev.2
Overview
Before starting measurements technique there are
many points to be explained to have a clear
understood and the meaning of each term.
Properties of Vibration
Frequency
Amplitude
Phase
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 307 6th June 2011 / Rev.2
Vibration Frequency
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 308 6th June 2011 / Rev.2
Amplitude
The amplitude is the amount of vibration motion, or the distance that the
system will vibrate or move from its equilibrium position which is termed
as vibration displacement. The change of distance with respect to time, is
the second term of amplitude and called as vibration velocity. The
change of velocity with respect to Lime is the third measure and termed
as vibration acceleration.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 309 6th June 2011 / Rev.2
The amplitude of vibration is expressed as follows:
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 310 6th June 2011 / Rev.2
Vibration Phase
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 311 6th June 2011 / Rev.2
Measurement Positions and Directions
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 312 6th June 2011 / Rev.2
Velocity Pick-ups
Velocity pick-ups are the most widely used for vibration measurement
in general cases, and analysis. It is light and hand held. It is
constructed. As from theories the movement of a coil in a magnetic
field produces certain voltage depends in its value on velocity of
movement. The velocity pick-ups measure vibration frequencies
higher than the natural frequency off the spring-mass system of the
pick-up. This self generating, and not required any outside excitation.
It is called seismic transducers.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 313 6th June 2011 / Rev.2
Velocity pick=up range
operation.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 314 6th June 2011 / Rev.2
Acceleration Transducers
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 315 6th June 2011 / Rev.2
Non Contact Pick-ups
This type is used for high speed machines to measure relative shaft
vibration. This is applied in case of high speed centrifugal pumps,
compressors and turbo generators. Non contact proximity can indicate
the case of each hearing, the gap measurement, and the shaftrun out.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 316 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 317 6th June 2011 / Rev.2
Axial Position Measurement
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 318 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 319 6th June 2011 / Rev.2
SHAFT ALIGNMENT
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 320 6th June 2011 / Rev.2
ALIGNMENT
The purpose of shaft alignment is to position the driving machine
shaft accurately in relation to the driven machine shaft. Misalignment
causes sever stresses to both driver and driver machine parts. The
meaning of alignment is that the center line of driver machine such as
on electrical motor, steam turbine, or gas turbine must be concentric
with the center line of the driven machine such as a pump, compressor
or electrical generator.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 321 6th June 2011 / Rev.2
Results of misalignment are briefly as follow:
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 322 6th June 2011 / Rev.2
Thermal Expansion
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 323 6th June 2011 / Rev.2
The amount and direction of this growth of heat can be accurately taken,
into consideration for smooth and efficient operation of the equipment
thermal expansion becomes a critical problem. The designer must
attempt to represent the thermal growth in vertical and horizontal planes.
Fig shows the effect of thermal expansion on the centre lines of rotating
equipment.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 324 6th June 2011 / Rev.2
Misalignment Types
Parallel Misalignment
Angular Misalignment
Combination Misalignment (Parallel and Angular)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 325 6th June 2011 / Rev.2
Misalignment
Misalignment exists when there is a sliding motion between the
floating members of a coupling. The degree of misalignment of a
coupling can be tolerated during operation without having an adverse
effect on the coupled machines. This is known as the allowable
alignment tolerance. The misalignment we are concerned with is a
degree of misalignment between the floating members of the coupling.
The basic objective in coupling alignment is to eliminate or control the
amount of movement between the floating members of the coupling as
well as to reduce the shaft misalignment to an acceptable level, be
within alignment tolerances.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 326 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 327 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 328 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 329 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 330 6th June 2011 / Rev.2
Parallel and angular misalignment are in two planes
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 331 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 332 6th June 2011 / Rev.2
Alignment Procedure
Using Straight edge and feeler gauge:
a. Side View
Readings are taken at 12 oclock (Top) and 6 oclock (Bottom). In this
view adding shims or removing shims under the movable machine.
b. Top View
Readings are taken from the pump at 3 oclock (Right) and 9 oclock
(left). In this view moving the movable machine.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 333 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 334 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 335 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 336 6th June 2011 / Rev.2
Loosen the mounting bolts enough to move the motor must be equally
from the near and the rear foot or from the middle between the near
and far foot and using a hard rubber hammer or brass hammer with
flexible handle.
Tight the mounting bolts and check from side view and top view.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 337 6th June 2011 / Rev.2
Note:
In lateral adjustment move the motor equally from near and rear foot
from right (3 oclock) to left (9 oclock) or vice versa.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 338 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 339 6th June 2011 / Rev.2
Note that:
If the largest gap is at 12 oclock shims must be put under far foot of the
motor.
If the largest gap is at 6 oclock shims must be put under the near foot or
the Motor.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 340 6th June 2011 / Rev.2
Section 8
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 341 6th June 2011 / Rev.2
Fuel Unloading Pumps
Unloading Pumps
Pump Motor
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 342 6th June 2011 / Rev.2
Fuel Unloading / Forwarding / Transfer
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 343 6th June 2011 / Rev.2
Fuel Unloading / Forwarding / Transfer
Our experience shows that when fuel is allowed to sit in a rail car, tank truck,
etc. the viscosity of the fluid can increase. This change results increased
input torque requirements and potentially the delivered. In positive
displacement pumps, the delivered flow will increase and in centrifugal
pumps the amount will be decrease. It is important when sizing your pump to
consider the properties of the fluid, pressure, supply and operational
objectives.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 344 6th June 2011 / Rev.2
Unloading Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 345 6th June 2011 / Rev.2
Unloading Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 346 6th June 2011 / Rev.2
Fuel Unloading Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 347 6th June 2011 / Rev.2
Fuel Unloading Pumps
Etachrom NC 040-160 SP
Standardpump acc. EN 733
Operating Data
Requested flow rate 50.00m3/h Actual flow rate 50.03m3/h
Requested developed head 30.00 m Actual developed head 30.04 m
Pumped medium Fuel, kerosene Efficiency 73.7%
Kerosene JP4 Power absorbed 4.28kw
Materials are not affected by Pump speed of rotation 2929rpm
chemical and mech. substances NPSH required 3.15m
Fluid temperature 20.00C Permissible operating pressure 12.00bar.g
Fluid density 770 kg/m3 Discharge press. 2.27 bar.g
Fluid viscosity 0.50 mm2/s
Motor Connections
Motor manufacturer KSB Suction nominal size DN1 DN 65 / EN 1092-2
Motor size 132S Discharge nominal size DN2 DN 40 / EN 1092-2
Motor power 5.50kw Nominal pressure suct. PN 16
Speed of rotation 2929 rpm Rated pressure disch. PN 16
Position of terminal box 00/3600 (top) Flanges DN65 will be drilled with 4
holes
Baseplate Coupling
Design U-Beam / folded plate Coupling manufacturer Flender
Size 1A Coupling type Eupex N
Material Steel ST Coupling size 80
Leakage drain, baseplate RP1 Without Spaces 0.0 mm
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 348 6th June 2011 / Rev.2
Fuel Unloading Pumps
Performance curve
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 349 6th June 2011 / Rev.2
Types of Fire Pumps
Centrifugal Pumps.
Can not pump Air
Capable of 100% slippage.
The main fire pump used on modern fire apparatus.
Classified as a nonpositive displacement pump.
Imparts velocity on water and coverts it to pressure.
Single or multiple stage.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 350 6th June 2011 / Rev.2
Fire Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 351 6th June 2011 / Rev.2
Horizontal Split case Design
Impeller Double Suction Type
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 352 6th June 2011 / Rev.2
Overhung End Suction API
Standard Process Pump
Operating Parameters:
Flows to 1100 m3/h (4800 gpm)
Heads to 230m (755ft)
Temperatures to 350 c (660 f)
Working pressures to 60 bar ( 870 psi)
Suction pressures to 50 bar ( 725 psi)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 353 6th June 2011 / Rev.2
Reddy Buffaloes Pumps
(Used for Electrical and Diesel fire pumps)
Fire Pumps Overview
Horizontal Split Case Fire Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 354 6th June 2011 / Rev.2
Reddy Buffaloes Pumps
A fire pump is a part of a fire sprinkler systems water supply and can be
powered by electric, diesel or stream. The pump intake is either connected to
the public underground water supply piping, or a static water source (e.g., tank,
reservoir, lake).
The pump provides water flow at a higher pressure to the sprinkler system
risers and hose standpipes. A fire pump is tested and listed for its use
specifically for fire service by a third-party testing and listing agency, such as UL
or FM Global. The main code that governs fire pump installations in North
America is the National Fire Protection Associations NFPA 20 Standard for the
Installation of Stationery Fire Pumps for Fire Protection.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 355 6th June 2011 / Rev.2
Reddy Buffaloes Pumps
Operation
The pump starts when the pressure in the fire sprinkler system drops a
threshold. The sprinkler system pressure drops significantly when one or
more fire sprinklers are exposed to heat above their design temperature, and
opens, releasing water. Alternatively, other fire hoses reels or other
firefighting connections are opened, causing a pressure drop in the fire
fighting main.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 356 6th June 2011 / Rev.2
Reddy Buffaloes Pumps
General
Horizontal Split Case pumps have
been specifically designed for fire
pump requirements, utilizing the latest
hydraulic techniques available. All the
fire pumps are manufactured to high
standards of quality in the material,
construction, and workmanship of
each unit.
Casing
The casing are of high quality cast
iron, with a minimum tensile strength
of 40,000 PSI. The casing is a split-
case design simplifying inspection
and disassembly.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 357 6th June 2011 / Rev.2
Reddy Buffaloes Pumps
Shaft
The shafts are alloy steel, machined and ground to close tolerances. They are
sized to transmit the torque and handle the imposed hydraulic loads, all while
maintaining a minimum amount of deflection under any flow condition.
Impeller
The double-suction impellers are bronze, enclosed design, keyed to the shaft, and
secured by adjustable shaft sleeves. All impellers are dynamically balanced to
ensure smooth operation. The double suction feature balances out hydraulic
thrust loads. Impeller wear rings are an available option.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 358 6th June 2011 / Rev.2
Reddy Buffaloes Pumps
Shaft Sleeves
To protect the shaft against wear and corrosion, bronze shaft sleeves are
provided. The shaft sleeves are threaded to the position and hold the impeller in
place. The sleeves are double set screwed and key locked to prevent their rotation
in either direction. They extend from the impeller to slightly beyond the seal box
area.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 359 6th June 2011 / Rev.2
Fire Fighting Sets
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 360 6th June 2011 / Rev.2
Fire Pumps
Standard Sizes
NFPA20 standard Fire Pump Capacities (GPM)
20 50 100 150 200 250 300 400 450 500 750 1000 1250 1500 2000 3000 3500 4000 4500 5000
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 361 6th June 2011 / Rev.2
Fire Pumps
N.F.P.A # 20 deals with the selection
and installation of pumps supplying
water for private fire protection. This
standard covers the application, test,
operation and maintenance of the fire
pump system. N.F.P.A # 20 is the basic
standard for centrifugal fire pumps and
is recognized by both stock and mutual
insurance organizations. Each of these
maintains their own standards, testing
facilities and approving organizations.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 362 6th June 2011 / Rev.2
Fire Pumps
LABELED FIRE PUMPS
All labeled fire pumps must be specifically approved and/or listed for fire pump
service. The capacity ratings are established by N.F.P.A#20 and are
recognized by both UL. and FM. The selection tables in the following Section
1510 cover the permissible operating ranges for electric motor and diesel
engine driven fire pumps. They have unique performance criteria which must
be met in order to be labeled. The following defines the performance
requirements of the Horizontal Fire Pumps.
All UL. Listed pumps will have All FM. approved fire pumps will All ULC listed fire pumps will
the above identification mark have the above identification have the above identification
on pump nameplate. mark on pump nameplate mark on pump nameplate
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 363 6th June 2011 / Rev.2
Fire Pumps Standard
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 364 6th June 2011 / Rev.2
Fire Pumps Standard
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 365 6th June 2011 / Rev.2
Fire Pumps Standard
Pumps Group
Pumps Group used for building fire fighting sets. They get combined in
different installations according to the operation conditions.
1) Fire fighting set with one pump or multiple pumps with electric motor
2) Fire fighting set one electric motor driven and one diesel engine driven
pump.
3) Fire fighting set with one electric motor driven and one diesel engine driven
and one jockey Pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 366 6th June 2011 / Rev.2
Fire Pumps Standard
The main goal of the use of multiple pumps is to have standby pump or in
case of capacity increase it is needed to change the fire fighting set. Pumps
in fire fighting set with 2 or 3 pumps must be fully complying with each other.
The goal of Jockey pump use is to sustain pressure value in the piping
installation in case of pressure leaks, without operating the main pumps.
Vertical multi stage pump used as jockey pumps.
Capacity (Q) of the jockey pumps must be 1% of main pumps capacity and
discharge head of the jockey pump must be 10m more than that of main
pump.
Example: If discharge capacity head of the main pump is
170m3/h and discharge head of the main pump is 60m,
discharge capacity of the jockey pump must be 1,7 m3h
and discharge head of the jockey pump must be
60+10=70m
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 367 6th June 2011 / Rev.2
Fire Pumps Protection Systems
Most modern fire protection systems are designed to operate automatically (as
opposed to manual start). The starting sequence is initiated by a pressure
drop caused by activation of an automatic sprinkler or a deluge valve. In order
to keep the system filled and pressurized without activating the main fire pump
(s), a jockey or pressure maintenance pump is used.
The jockey pump is small, so that it can restore small system pressure losses
but cannot fulfill the large flow / pressure demands caused by activation of the
fire protection system. Any pump which is suitable for the application may used
for jockey pump service; jockey pumps are not covered by UL listing nor FM
approval requirements.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 368 6th June 2011 / Rev.2
Fire Protection Systems
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 369 6th June 2011 / Rev.2
Fire Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 370 6th June 2011 / Rev.2
Fire Pump Fittings
Horizontal Fire Pumps
Electric motor or Diesel Engine
Driven
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 371 6th June 2011 / Rev.2
Fire Pump Fittings
In-Line Pumps
Capacity to 1500 GPM
(5,678 L/min)
Pressures to 165 PSI (116m)
Working Pressures to 150 PSI
Space saving design
No foundation or pads required.
Suction and discharge flanges are on a
common centerline, 1800 apart for inline
mounting in piping.
Top pullout design allows for fast and easy
servicing. The rotating element is easily
removed without disturbing suction and
discharge piping.
Self-venting design eliminates the need for
and automatic air release valve.
Bronze impeller is dynamically balanced
and keyed direct to the motor shaft.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 372 6th June 2011 / Rev.2
Fire Pump Fittings
End Suction Pumps
Capacity to 500 GPM
(1,892 L/min)
Pressures to 150 PSI (106m)
Working Pressures to 250 PSI
Top centerline discharge with foot supported
casing.
Easing of installation.
Simplifies piping layout
Reduces problems associated with piping strain.
Self-venting designs eliminates the need for automatic air
release valve.
Rear pullout design supplied as standard with spacer coupling.
Ease of maintenance, eliminates disturbing driver or piping
when removing rotating element.
Hydraulically balanced impeller extends bearing life and assures
smoother operation.
Available in electric motor or diesel engine driven configuration.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 373 6th June 2011 / Rev.2
Fire Pump Fittings
Vertical Turbine Pumps
Capacity to 5000 GPM
(18,925 L/min)
Pressures to 350 PSI (247m)
Working Pressures
-upto 200PSI with 125 lb. A.S.A flanges
-upto 550PSI with 250 lb. A.S.A flanges
Required by NFPA when operating under a static suction
lift condition.
Dynamically balance impellers secured to the shaft with
steel locking collects to assure proper problem free
operation.
Open lineshaft design provides for product lubrication of
the bearings.
Available in electric motor or diesel engine driven
configuration.
Provided with a bronze suction strainer as standard.
Provided with an oversized air release valve as standard.
Available in special materials of construction for salt water
applications.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 374 6th June 2011 / Rev.2
Electric Motor Driven Fire Pump System
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 375 6th June 2011 / Rev.2
Electric Motor Driven Fire Pump System
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 376 6th June 2011 / Rev.2
Electric Motor Driven Fire Pump System
Jockey Pump: Jockey pump keeps pressure in the system to prevent the
main fire pump from operating to maintain system pressure. Jockey pumps
are generally a few gallons per minute sized to overcome small system leaks
and typically sized for 10PSI greater than the rated pressure of the main fire
pump. Jockey pumps are not required to be UL Listed or FM Approved.
Jockey Pump Controller : Starts the jockey pump across the line by sensing
pressure via a sensing line from the system side of the check valve. This
sensing line must be independent from the main fire pump controller sensing
line. Controller is sized per the jockey pump motor horsepower and voltage.
Jockey pump controllers are UL Listed specifically for this service.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 377 6th June 2011 / Rev.2
Split Case Fire Pumps
8100 Series
Capacity to 3000 GPM
(11,355 L/min)
Pressures to 255 PSI (179m)
Working Pressures
-upto 250 PSI (176m) with 125 lb. A.S.A flanges
-upto 375 PSI (264m) with 250 lb. A.S.A flanges
Space saving design.
Available in horizontal or vertical
configuration.
Suction and discharge flanges are on a
common centerline.
Bearing span is kept to a minimum
Available in electric motor driven or engine
driven configuration.
Available in clockwise or counter-clockwise
rotation to simplify pump room layout.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 378 6th June 2011 / Rev.2
Split Case Fire Pumps
8200 Series
Capacity to 1000 GPM
(3785 L/min)
Pressures to 640 PSI (450m)
Working Pressures
-upto 500 PSI (352m) with 250 lb. A.S.A flanges
-upto 800 PSI (563m) with 800 lb. A.S.A flanges
Space saving design.
Suction and discharge flanges are on a common
centerline.
Bearing span is kept to a minimum
Compact pump design.
Dual volute casing balances radial forces on the shaft
and bearings.
Available in eclectic motor driven or engine driven
configuration.
Two stage pump with two impellers threaded together.
Dynamic balanced impellers.
Available in clockwise or counter-clockwise rotation to
simplify pump room layout.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 379 6th June 2011 / Rev.2
Split Case Fire Pumps
9100 Series
Capacity to 5000 GPM
(18925 L/min)
Pressures to 208 PSI (146m)
Working Pressures
-upto 175 PSI (123m) with 125 lb. A.S.A flanges
-upto 255 PSI (180m) with 250 lb. A.S.A flanges
Space saving design.
Suction and discharge flanges are on a
common centerline.
Dual volute casing balances radial forces
on the shaft and bearings.
Available in eclectic motor driven or
engine driven configuration.
Available in clockwise or counter-
clockwise rotation to simplify pump room
layout.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 380 6th June 2011 / Rev.2
Fire Pump Drivers
Fire Pump Drivers
Drivers include various types of electric motors and labeled diesel engines. The
driver must be selected to provide the maximum horsepower required by the
pump anywhere along its performance curve.
(By way of explanation, spark ignition internal combustion engines and dual
drives a motor and an engine as alternate drivers on the same pump have
not had NFPA approval since 1974 edition of Pamphlet20)
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 381 6th June 2011 / Rev.2
Electric Motor Driven Fire Pump System
Electric Motors
Electric motors have been matched to the pump
when designed and should meet NFPA70, Article
695, as well as other applicable articles. Electric
motors for fire pumps normally (but not always)
have dedicated electric feeds, which are located
before all other plant disconnecting means. This
means that if all power is shut off to the facility, the
power to the fire pump will continue to operate,
feeding water to the fire protection systems.
Controllers for electric pumps should be located
with in sight of the motors. Since these units are
installed on motors expected to function on an Two vertical turbine fire pumps taking
emergency basis, they are provided with fuses rated suction from reservoir. The pump room
floor is the top of the water reservoir. The
at a much higher capacity than nonemergency rated near unit has an electric motor mounted
motors. They will not shut down on over current vertically on the pump. Behind is a diesel
power conditions as other normal motors and will driven vertical turbine pump with a right-
continue operating under adverse conditions, even angle drive.
to the point of self-destruction.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 382 6th June 2011 / Rev.2
Diesel Engine Driven Fire Pump System
Diesel Engines
Diesel engines are also matched to the pump
they will power. They are designed and arranged
for emergency service and will have features not
normally provided on nonemergency equipment.
In the event of unusual operating conditions, it
may run to destruction to continue providing
water to fire protection systems.
Diesel engines have two battery storage units,
which, at 400 F (4.50C), have twice the capacity
sufficient to maintain the cranking speed
recommended by the engine manufacturer. They
must be capable of maintaining a 3-minute
attempt-to-start cycle, which is six consecutive A diesel-driven horizontal split-case fire
pump. The instrument panel is at the top of
cycles of 15 seconds of cranking and 15 seconds
the engine. The cooling line and bypass are
of rest. The attempt-to-start cycle is important to located alongside of the engine. The batteries
ensure that adequate reserve battery capacity are located on the opposite side of the
exists to attempt multiple starts of the unit, if engine so the operator does not stand in
front of, or reach over them, to operate the
needed. pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 383 6th June 2011 / Rev.2
Section 9
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 384 6th June 2011 / Rev.2
Electrical Fire Pump
Pump Drawings.
Pump Curves.
Pump Controller.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 385 6th June 2011 / Rev.2
Fire Pump
Most fire pumps are either diesel engine driven or electric motor driven,
depending on the situation. Automatic Fire Protection can advise which
pump type best suits each application.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 386 6th June 2011 / Rev.2
Electrical Fire Pump
Horizontal Split Case Fire Pumps
Most stationery fire pumps are driven by electric motors. To justify the use of an
electric motor, a single power station or substation which can guarantee
virtually uninterrupted power is preferred. If the source cannot guarantee
continuous power, the power must be supplied by two or more stations located
and equipped so that an accident or a fire at one will not cause an interruption
of the power supplied by the other.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 387 6th June 2011 / Rev.2
Fire Pump Controller
FIRE FIGHTING SET CONTROL SYSTEM:
Separate control panels used for jockey pumps and for main pumps.
Main pumps can operate as standby pump for each other or they can
operate together.
Control panels have available connections terminals for building automation.
Electric motor of main pump has star delta connection.
There are 2 batteries and battery charge system for diesel engine
There is no terminal protection for main pump control panel
Controls on electric motor driven pump on control panel door:
Manual start stop button
Energy signal lamp
Test operation signal lamp
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 388 6th June 2011 / Rev.2
Fire Pump Controller
Panel equipped with alarm signal buzzer and lamp
Control panel supply voltage is 24 V
Diesel engine control panel has following on panel door:
Diesel engine operating lamp
Excessive speed warning lamp
Diesel engine failure signal lamp
Excessive engine heat signal lamp
Low battery warning signal
Low oil pressure signal lamp
Minimum fuel signal lamp
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 389 6th June 2011 / Rev.2
Electric Fire Pump Systems
When theres a call to start a fire pump in an emergency situation, you need a
fire pump controller that you can count on to start every time, without fail
because life safety depends on it. Eatons fire pump controllers are designed
and manufactured in accordance with the strictest fire protection, electrical
and insurance codes in the world, thereby ensuring they meet or exceed all
required standards.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 390 6th June 2011 / Rev.2
Electric Fire Pump Systems
Diesel Engine Controllers
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 391 6th June 2011 / Rev.2
Electric Fire Pump Systems
Electric Fire Pumps
When it comes to fire pump controllers, none of this is true. In the event of
fire, you must start and run that pump. NFPA 20 considers conductors and
some equipment supplying power to the fire pump motor sacrificial in favor
of starting and running. If possible, we expect the fire pump controller to
default to a nuisance start and run; regardless of anomalies. If you work
with fire pump controllers, you need NFPA 20.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 393 6th June 2011 / Rev.2
Electric Fire Pump Systems
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 394 6th June 2011 / Rev.2
Electric Fire Pump Drawing
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 395 6th June 2011 / Rev.2
Electrical Fire Pump Curves
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 396 6th June 2011 / Rev.2
Diesel Fire Pump
Pump Drawings.
Pump Curves
Controller.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 397 6th June 2011 / Rev.2
Diesel Fire Pump
Labeled diesel engines are frequently used to drive stationary fire
pumps. Equipped with battery packs and automatic controls. They rival
electric motors for reliability and eliminate concern over the dependability
of the source of electrical power. However, they do require additional
considerations.
Diesel engines are rated to produce their maximum horse powers at 500
feet altitude above sea level and 850F ambient air temperature. As these
conditions change, the following
deductions apply:
Reduce horse power by 3% for each additional 1,000 feet of
elevation.
Reduce horsepower by 1% for each 100F above 850F ambient air
temperature.
If the listed engine with the required horsepower is not available, the
engine chosen must produce at least 10 horsepower required by the
pump anywhere along its performance curve.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 398 6th June 2011 / Rev.2
Diesel Fire Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 399 6th June 2011 / Rev.2
Diesel Fire Pump
Ideal for both high and low pressure pumping requirements.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 400 6th June 2011 / Rev.2
Diesel Fire Pump
The simple, split case design of
these pumps allows for in-line
service without disturbing piping
while ensuring long, efficient
unit life, reduced maintenance
costs and minimal
power consumption.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 401 6th June 2011 / Rev.2
Diesel Engine Information
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 402 6th June 2011 / Rev.2
D.F. Pump Drawings
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 403 6th June 2011 / Rev.2
D.F. Pump Curves
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 404 6th June 2011 / Rev.2
A Vertical Turbine Type Fire Pump with
a Diesel Engine
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 405 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 406 6th June 2011 / Rev.2
Jockey Pump
(Fire Fighting System)
Pump Information
Pump Controller
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 407 6th June 2011 / Rev.2
What is a Jockey Pump?
A Jockey pump, or a pressure maintenance pump, is a
small apparatus that works in conjunction with a fire
pump as part of a fire protection sprinkler system. A
jockey pump is designed to keep the pressure elevated
in a fire suppression system so that the main fire pump
is prevented from running unless absolutely necessary.
It consists of a motor, a pump, and a controller.
When a fire sprinkler is exposed to heat, the pressure
in the system drops significantly and a valve opens,
releasing water. The main fire pump provides the
pressure to the system that creates water flow from
when this one sprinkler is activated, the pressure drops
so drastically that the fire pump starts working, and the
fire department is alerted. The jockey pump works as
part of the fire pumps control system, riding on top of
the larger pump like a jockey.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 408 6th June 2011 / Rev.2
Jockey Pump
A Jockey Pump is a small pump connected to a fire sprinkler system and is intended to
maintain pressure in a fire protection piping system to an artificially high level so that
the operation of a single fire sprinkler will cause a pressure drop which will be senses
by the fire pump automatic controller, causing the fire pump to start. The jockey pump is
essentially a portion of the fire pump s control system.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 409 6th June 2011 / Rev.2
Jockey Pump
Two Types of Pumps:
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 410 6th June 2011 / Rev.2
Jockey Pump Controller
Jockey Pump Controller
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 411 6th June 2011 / Rev.2
Jockey Pump Controller
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 412 6th June 2011 / Rev.2
Jockey Pump Controller
STANDARD EQUIPMENT AND PERFORAMNCE
Automatic start responsive to water pressure with integral
pressure sensing switch.
Independent high (stop) and low (start) adjustments points on
pressure switch.
Standard Pressure Switch Range is 20 290 PSI, 50 450 PSI is
optional.
Manual electric start and stop from Side mounted Hand-Off-Auto
selector switch.
IEC rated magnetic 3-pole motor contactor.
IEC Motor Circuit Protector with Adjustable range over current
Trip protection.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 415 6th June 2011 / Rev.2
Submersible Pumps
Submersible Pumps :
submersible pumps, also referred to as Electric submersible pumps (ESP), are
mechanisms containing a motor encased in an airtight container which can be set
into liquid in order to help push the liquid to the surface. Unlike a jet pump, which
works by actively pulling water into itself, electric submersible pumps are much
more efficient and cost effective. A submersible pump is designed for a wide range
of uses, including residential, commercial, and industrial purposes, and come in a
wide range of sizes and price points to meet more specific needs.
Applications:
Submersible pumps are found in many applications. Single stage pumps are used
for drainage, sewage pumping, general industrial pumping and slurry pumping.
They are also popular with aquarium filters. Multiple stage submersible pumps are
typically lowered down a borehole and used for water abstraction, water wells and in
oil wells.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 416 6th June 2011 / Rev.2
Submersible Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 417 6th June 2011 / Rev.2
Submersible Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 418 6th June 2011 / Rev.2
Submersible Pumps
Dual Seals.
Double protection
Primary seal keeps dirty water in the
pump end and prevents contamination
of the oil cavity. A second fail safe
seal provides extra protection against
the possibility of damage to the motor.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 419 6th June 2011 / Rev.2
Submersible Pumps
Submersible pump is a pump that is able to be placed
underwater and still carry out its intended purpose. Some
pumps may be designed to work while being fully submerged,
whereas others may be submerged or placed in a dry area. It is
important to understand what type of pump you are dealing with
in order that no damage is incurred when it is being used.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 420 6th June 2011 / Rev.2
Submersible Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 421 6th June 2011 / Rev.2
Submersible Pumps
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 422 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 423 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 424 6th June 2011 / Rev.2
X71 HAZARDOUS ENVIRONMENT SERIES
CLASS 1, DIVISION 1, GROUPS C & D
GRINDER PUMPS TECHNICAL DATA
3, 5 & 7 BHP
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 425 6th June 2011 / Rev.2
Submersible Sewage Pumps
A submersible sewage pumps is mounted within the sewage tank itself and is designed to work
when fully surrounded by the sewage it is designed to pump. The motor of a submersible
sewage pump is contained inside an oil filled cavity designed to house to the motor and protect
it from contact with the waste material surrounding it. A lip or a mechanical seal protects the
motor from the liquid. They are designed to pump or grind large solids to smaller sizes.
Watertight splice connection box.
An-1-1/4 PVC Ball valve is Installed at the 1-1/4 Bulk
head discharge fitting to prevent sewage from draining
back into the tank after disconnection.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 427 6th June 2011 / Rev.2
Vertical Sump Pumps
- General Overview.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 428 6th June 2011 / Rev.2
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 429 6th June 2011 / Rev.2
VERTICAL SUMP PUMPS
Vertical sump Pumps are designed for general sump dewatering application. These
unit are available in a wide range of configuration in both Simplex and Duplex
designs. These units can be sullied in a board range of materials from Cast Iron to
Alloy 20 and in settings up to 20 Fit. Sump depth. Flows range from 20 GPM to
4000 GPM with heads up to 250 Fit TDH.
Use for a following applications: Industrial Process, Industrial & Commercial Sump
Drainage, Corrosive & Non Corrosive Liquids, Dewatering Service, Pollution
Control, Condensate Return and variety of other services.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 430 6th June 2011 / Rev.2
Sump Pump Types
There are two different types of sump pumps. Pedestal sump pumps have
their motor located above thank so that it is easily accessible and can be
services. The other type is a submersible pumps located inside the pit,
which is sealed off with a sump pump cover.
Pedestal: This type is an upright electric sump pump
whose motor is located above the pump as it is not
meant to get wet. It has a float-activated switch that
turns the pump on when the water reaches a certain
level. It is ideal for basements needing frequent water
drainage. They are usually the least expensive but
tend to be noisier than the submersibles.
Submersible: This electric sump pump is installed in
ground and specifically designed to function
underwater. It has the same float activated switch as
the pedestal. Submersibles are more expensive, but
boast a longer life than the pedestal type. Their
sealed, oil-cooled motors are protected from moisture
and dust, making them quieter.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 431 6th June 2011 / Rev.2
SUMP PUMP
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 432 6th June 2011 / Rev.2
Sump Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 433 6th June 2011 / Rev.2
Sump Pump
SIP-V
SIP hydraulic design line shaft wet bearings
Bearing Material ; metallic, carbon, ceramic
Thrust bearing at pump heads
Recessed TF Impeller option.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 434 6th June 2011 / Rev.2
Sump Pump
Cyclone Separator
For bearing Flush and Tailpipe
mounted on a pump.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 435 6th June 2011 / Rev.2
Sump Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 436 6th June 2011 / Rev.2
Sump Pump
Details of design features:
Impeller and agitation options VS
Four different impeller and two agitation options are available for optimum performance.
Type O The semi-open impeller provides better solids handling than the closed impeller
design and is less sensitive to air blocking on intermittent operation.
Type W Vortex induced Flow impeller for clogless pumping of long fibrous or coarse
solids. It can be fitted into a casing with or without spray holes. Large clearance between
casing and impeller- well suited for pumping fibrous slurries (paper stock, wood chips,
municipal sludge, etc.), aerated or frothy liquids (vortex impeller will not be air blocked) and
any applications where the pump is required to pass the occasional large solids.
Type WFR We have developed a fully recessed induced vortex impeller for the VSHM
pumps. This is specifically designed for carbon transfer in gold leaching processes because
it provides the lowest possible attrition of the pumped active carbon particles.
Type C Closed impeller for higher heads and efficiencies. Can not be combined with type
S, Casings with spray holes.
Type A Semi-open impeller and robust extended shaft with a slurry agitator. This design is
best suited for coarse rapid settling solids and dredging type applications.
Type S Pump casing with spray holes. The spray holes direct some of the slurry towards
the sump bottom, thereby agitating settled solids. Available from VS50 to VS200.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 437 6th June 2011 / Rev.2
Sump Pump
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 438 6th June 2011 / Rev.2
Quality Design Feature Assure Long,
Trouble-Free Service
WIDE RANGE OF APPLICATIONS:
Chemical Slurries
Fragile Food Processing Solids
Paper & Pulpy Solids
Petroleum
Oils
Sewage & Waste Treatment
Textiles
CAPABILITIES:
Capacities to 1600 GPM
Heads to 170 Feet
Temperature to 2500F
Pit Depths to 26 Feet
Construction: Cast Iron, 316 Stainless Steel Fitted, All 316
Stainless Steel, Alloy 20, CD4MCu
Solid Handling upto 4 Diameter Spheres
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 439 6th June 2011 / Rev.2
WIDE RANGE OF APPLICATIONS:
Industrial Process
Pollution Control
Sump Drainage
Flood Control
Hazardous, Toxic & Inflammable Liquids
Clear Liquids
Condensate
Corrosive Liquids
Acids
CAPABILITIES:
Capacities to 3000 GPM
Heads to 230 Feet TDH
Temperature to 3500F
Pit Depths to 26 Feet
Construction: Cast Iron, 316 Stainless Steel Fitted, All
316 Stainless Steel, Alloy 20, Hastelloy, CD4MCu
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 440 6th June 2011 / Rev.2
Installing a sump pump can help protect your
basement from flooding.
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 441 6th June 2011 / Rev.2
Vertical Sump Pumps, Type ET and Type ETT
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 442 6th June 2011 / Rev.2
Sump Pumps Curves
AWI 106 Att. 8 Rev. 3 02 Jan. 2011 443 6th June 2011 / Rev.2