Anda di halaman 1dari 9

Access KPI Analyze summary

Jan 2017

HUAWEI TECHNOLOGIES CO., LTD.


Access KPI Analysis Root Cause checklist Workflow

Category Check List


Start
RNC available check
Operation Log Check
The whole RNC or Network KPI Degrade Transmission check
Phenomena analyse Alarm check
Local Event check
Proposal Transmission check
Operation Log Check
Alarm check
Yes TOP Cell Degradation Load balance strategy Parameter Check
Whole RNC or network
KPI Degrade A CE UL Group Check
CE & Code License Check
Local Event check
No
Others TOP UE or TOP Subscriber

TOP Cell degradation


Remark:
Yes
 RNC Level KPI Degradation judgment Reference
High traffic and Many users B If remove top 20% low CSSR and high Attempts failures but after the KPI re-
calculation still not reach the target
 TOP Cell KPI Degradation judgment Reference
If remove top 20% low CSSR and high Attempts failures and after the KPI
No
Problem Solved C re-calculation can reach the target
 TOP User or Subscriber
Yes If after check everything but still can not solve problem, check top IMSI from
PCHR, and request for customer to add blacklist of top cell
End For Optimization Proposal , Kindly see next slide
Access KPI Analyze Work Flow_Proposal
A .RNC Parameter
Actions Command Parameters Proposed Value
To improve CSSR URRCTRLSWITCH RB_SETUP_RL_REEST_SWITCH On
To improve CSSR URRCTRLSWITCH RB_SETUP_ENHANCE_RL_REEST_SWITCH On
To improve CSSR URRCTRLSWITCH RB_RLREEST_AM_TRB_RLC_REEST_SWITCH On
To improve CSSR URRCTRLSWITCH RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH On
To improve CSSR URRCTRLSWITCH RB_SETUP_F2D_CU_CROSS_OPT_SWITCH On
To improve CSSR URRCTRLSWITCH ASU_RSP_TIMEOUT_HANDLE_SWITCH On
To improve CSSR URRCTRLSWITCH CELLUPT_RLFAILURE_SRBREESTAB_SWITCH On
To improve CSSR URRCTRLSWITCH RB_REL_RL_REEST_SWITCH On
To improve CSSR URRCTRLSWITCH RB_RLREEST_AM_TRB_RLC_REEST_SWITCH On
To improve CSSR URRCTRLSWITCH PS_F2D_OVERLAP_CELLUPT_SWITCH On
To improve CSSR UCORRMPARA PERFENH_DRNC_CU_WITHOUT_EXTCELL_SWITCH On
To improve CSSR URRCTRLSWITCH RRC_CONN_SETUP_OPT_SWITCH On

B .High Load and Traffic Proposal


Actions Command Parameters MML Example
MOD UCELLSELRESEL QRXLEVMIN MOD UCELLSELRESEL: CellId=36122,QRXLEVMIN=-54;
Min Access Thd Optimization
MOD UCELLSELRESEL Qqualmin MOD UCELLSELRESEL: CellId=55182, Qqualmin=-14;
MOD UINTERFREQNCELL IdleQoffset MOD UINTERFREQNCELL: RNCId=603, CellId=22633, NCellRncId=610, NCellId=14146, SIB11Ind=TRUE, IdleQoffset1sn=0, IdleQoffset2sn=-10;
Load Balance among different carriers
MOD UINTERFREQNCELL CIOOFFSET MOD UINTERFREQNCELL: RNCId=610, CellId=8862, NCellRncId=610, NCellId=22711,CIOOFFSET=-7, SIB11Ind=TRUE, IdleQoffset1sn=0, IdleQoffset2sn=13;
MOD UCELLLDM ULLDRTRIGTHD MOD UCELLLDM: CellId=11, UlLdrTrigThd=35;
MOD UCELLLDM ULLDRRELTHD MOD UCELLLDM: CellId=11, UlLdrRelThd=25;
LDR related algorithm Optimization
MOD UCELLLDM ULOLCTRIGTHD MOD UCELLLDM: CellId=11, UlOlcTrigThd=98;
MOD UCELLLDM ULOLCRELTHD MOD UCELLLDM: CellId=11, UlOlcRelThd=88;
UPCPICH Power Optimization MOD UPCPICHPWR PCPICHPower MOD UCELL: CellId=55184, PCPICHPower=330;

C.Other RF Parameter Optimization Proposal


Category Command Parameters MML Example Priority
Power Congestion Optimization ADD UCELLCAC UlTotalEqUserNum ADD UCELLCAC:UlTotalEqUserNum=255; 1
SET UCORRMALGOSWITCH MAP_HSUPA_TTI_2MS_SWITCH SET UCORRMALGOSWITCH:MAP_HSUPA_TTI_2MS_SWITCH-0 2
CE Congestion Optimization SET UUSERGBR ULGBR SET UUSERGBR:TRAFFICCLASS=INTERACTIVE, THPCLASS=xx, BEARTYPE=HSPA, USERPRIORITY=xx, ULGBR=D32, 2
ADD UCELLFRC DlBeTraffInitBitrate ADD UCELLFRC:DlBeTraffInitBitrate=D32 1
MOD UCELLALGOSWITCH NBMLdcAlgoSwitch MOD UCELLALGOSWITCH:NBMLdcAlgoSwitch=DL_UU_LDR-1 1
Code Congestion Optimization ADD UCELLLDR: LdrFirstAction ADD UCELLLDR:LdrFirstAction=CODEADJ; 1
ADD UCELLHSDPA: HsPdschMinCodeNum ADD UCELLHSDPA:HsPdschMinCodeNum=1. 1
ADD UCELLFRC: DlBeTraffInitBitrate ADD UCELLFRC:DlBeTraffInitBitrate=D32 1
Attachment : Related Counters for Reference
Access KPI Reason
RRC Access Failure Counters PS RAB access Failure KPI category CS RAB Access Failures category
Category
VS.RRC.Rej.DLIUBBandCong VS.RAB.FailEstabPS.DLIUBBand.Cong VS.RAB.FailEstabCS.DLINBBand.Cong
VS.RRC.Rej.ULIUBBandCong VS.RAB.FailEstabPS.ULIUBBand.Cong VS.RAB.FailEstabCS.ULIUBBand.Cong
VS.RRC.Rej.UL.CE.Cong VS.RAB.FailEstabPS.ULCE.Cong VS.RAB.FailEstabCS.ULCE.Cong
Resource Congestion VS.RRC.REJ.DL.CE.Cong VS.RAB.FailEstabPS.DLCE.Cong VS.RAB.FailEstabCS.DLCE.Cong
VS.RRC.Rej.Code.Cong VS.RAB.FailEstabPS.Code.Cong VS.RAB.FailEstabCS.Code.Cong
VS.RAB.FailEstabPS.ULPower.Cong VS.RAB.FailEstabCS.ULPower.Cong
VS.RRC.Rej.Power.Cong
VS.RAB.FailEstabPS.DLPower.Cong VS.RAB.FailEstabCS.DLPower.Cong
VS.RAB.FailEstabPS.RBIncCfg VS.RAB.FailEstabCS.RBIncCfg
VS.RAB.FailEstabPS.RBCfgUnsupp VS.RAB.FailEstabCS.RBCfgUnsupp
UU Interface Failure VS.RRC.FailConnEstab.NoReply
VS.RAB.FailEstabPS.UuNoReply VS.RAB.FailEstabCS.UuNoReply
VS.RAB.FailEstabPS.PhyChFail VS.RAB.FailEstabCS.PhyChFail
VS.RRC.Rej.RL.Fail VS.RAB.FailEstabPS.IubFail VS.RAB.FailEstabCS.IubFail
Hardware & TRM
VS.RRC.Rej.TNL.Fail VS.RAB.FailEstabPS.TNL VS.RAB.FailEstabCS.TNL
Other Reason RRC.FailConnEstab.Other RAB.FailEstabPS.Other RAB.FailEstabCS.Other
Case Share :RNC Parameter Tuning to improve the PS CDR & CSSR
 Trend for PS CSSR and PS CDR In Sulawesi  Detail Tuned Parameters
Current Propose
MO Parameters Mod Reason
Value d Value
URRCTRLSWITCH ASU_RSP_TIMEOUT_HANDLE_SWITCH OFF On To improve CDR
URRCTRLSWITCH ASU_RSP_FAIL_REL_UE OFF On To improve CDR
URRCTRLSWITCH FACH_OUTOFSER_OPT_SWITCH OFF On To improve CDR
URRCTRLSWITCH D2F_PROCEDURE_OPTIMIZATION_SWITCH OFF On To improve CDR
URRCTRLSWITCH D2F_ABNORMAL_FORCETOFACH_SWITCH OFF On To improve CDR
UCORRMPARA PERFENH_RLRESETUP_GUARANTEE_SWITCH OFF On To improve CDR
URRCTRLSWITCH RB_SETUP_RL_REEST_SWITCH OFF On To improve CSSR
URRCTRLSWITCH RB_SETUP_ENHANCE_RL_REEST_SWITCH OFF On To improve CSSR
URRCTRLSWITCH RB_RLREEST_AM_TRB_RLC_REEST_SWITCH OFF On To improve CSSR
Current Team Qty URRCTRLSWITCH RB_SETUP_UM_TRB_RLREEST_ADJUD_OPT_SWITCH OFF On To improve CSSR
URRCTRLSWITCH RB_SETUP_F2D_CU_CROSS_OPT_SWITCH OFF On To improve CSSR
URRCTRLSWITCH ASU_RSP_TIMEOUT_HANDLE_SWITCH OFF On To improve CSSR
URRCTRLSWITCH CELLUPT_RLFAILURE_SRBREESTAB_SWITCH OFF On To improve CSSR
Tuning day URRCTRLSWITCH RB_REL_RL_REEST_SWITCH OFF On To improve CSSR
URRCTRLSWITCH RB_RLREEST_AM_TRB_RLC_REEST_SWITCH OFF On To improve CSSR
URRCTRLSWITCH PS_F2D_OVERLAP_CELLUPT_SWITCH OFF On To improve CSSR
UCORRMPARA PERFENH_DRNC_CU_WITHOUT_EXTCELL_SWITCH OFF On To improve CSSR
URRCTRLSWITCH RRC_CONN_SETUP_OPT_SWITCH OFF On To improve CSSR

During the tuning 3 days, the RNC level parameters were tuned step by step by
RNCs, PS Call setup Success Rate and PS Call Drop Rate improved obviously.
 Parameter Tuning Flow

Start Trial for one KPI Monitoring Yes Execute for Finish
KPI Improved
worst RNC for one day other RNCs
No
Troubleshooting Roll Back
And Root cause
After Optimize RNC Level parameters, the PS CSSR AND CDR improved.
Availability issue solved, the KPI back to normal
Availability issues that impact KPIs example
Top Cell1
Top Cell1 Top Cell2

Top Cell1

Alarm Alarm
Clear time Clear time

There were cell availability issue which is related by alarms, after the alarm solved, the KPI back to normal.
Activate Feature to solve CE congestion _1118
TOP Site :3313794G_3G_TANRUTEDONG
 Findings
Top site have Bad CSSR due to High CE Congestion on one day , after check the Uplink Group Resource, the CE board
distribution and local cell is unreasonable
 Solutions
 Re-plan the Uplink resource group
 Activate Interdependence of BBU Uplink Resource Feature

Bad CSSR
with High CE
Congestion

Activate Inter-dependence of BBU uplink resource feature, after activate, all the CE resource will be assigned dynamically.
Case Share: Missing Para Config cause bad CSSR
 Detail Analyze  CSSR Trend for Target site
Root Cause
 This NodeB are using ADJ Node ID=3035 to
mapping TRM
 In RNC Level ADJMAP parameter , the ADJ
Node=3035 was not added in ADJ Map

Bad CSSR for whole site, whole day CSSR back to normal

No ADJ
Node ID
=3035

Case Learning
If the dedicated ADJ Node is not added into ADJ Map, the system Rectify the Configuration
will use default IUB Mapping list to Mapping TRM, if the MML Command :ADD ADJMAP:ANI=3035, CNMNGMODE=SHARE,
correspond IPPATH were not configured, the service will be failed TMIGLD=50, TMISLV=50, TMIBRZ=50, FTI=50, ITFT=IUB, TRANST=IP;
3E852G_3G_SULTANALAUDIN Cell_58527 Low PS
CSSR_1103
Trend for CSSR of TOP Cell 58527(U2100) Analyze detail

Current Team Qty

 The CSSR is bad for cell 58527, analyze the traffic distribution, colo
cell 58527>58524>22381

 Check the CPICH Power, also 58527>58524>22381, it is necessary


to make power standardized to keep load balanced

 The CSSR is bad for cell 58527, after analyze, make the power of 3
colo cells standardized, the setup success rate improved , also, due
to load balanced, the traffic and payload increased.

After standardized the UPCPICH Power, the load balanced , and the CSSR improved

Anda mungkin juga menyukai