1. Set Access
3. 500 Hour Learning will start automatically after 3rd point of 3 Point Learning
finished.
/1/ 27-Jul-18
In CRP, Press the “ESC” or “Home” button.
And, click the “Config Displays” button. And
Click the “Sensor Configuration” button.
/2/ 27-Jul-18
In Sensor configuration page, click the “main menu” button in left top.
And, click the “Set Access” button.
/3/ 27-Jul-18
After typing the “41436” twice in blank. And, check the
Super user and Commissioning accessed.
And then, click the “EM Engine” button for Start of 3 point
calibration procedure.
Type the “41436” in blank one more time. => Commissioning user Access
/4/ 27-Jul-18
1
3 4
/5/ 27-Jul-18
In left side, click the “Commissioning” and “Main” button.
And then, click the “Start” button, When the M/E is Ahead
running condition. You will see the pop-up message. And
click the “Yes” for start of 3 point calibration procedure. Each
Step needs the 10 minutes in specific rpm.
/6/ 27-Jul-18
“Start” button will be changed to “Pause” status.
If you click the “Start” button, pop-up message will be displayed. And, click the
“OK” button. “Start” button will be changed to “Pause” status.
Never click the “Reset” button. “Reset” button initialize the 3 point calibration
procedure.
/7/ 27-Jul-18
Now, You set the rpm to First step rpm, And time left will count from 0 sec to 10 minutes.
▶After 10 minutes of First step of 3 point calibration, It takes about 5~6 minutes for saving compensation data to sensors at
First step rpm of 3 point calibration. Please, Just wait for 5~6 minutes to save the compensation data to sensors.
And then, “Not Logged” at First step rpm will changed to “OK” status with green color.
▶After First step rpm status is changed to “OK”, And then Set the rpm to Second step rpm.
After 10 minutes of Second step of 3 point calibration, “Not Logged” will changed to “OK” with green color in a few second.
▶At last, Set the rpm to Third step rpm. After 10 minutes of Third step of 3 point calibration, “Not Logged” will changed to
“OK” with green color in a minute.
After All 3 step is changed to “OK” with green color, 500Hrs Learning mode will start automatically.
/8/ 27-Jul-18
3 point Target rpm is
disappeared after
3 point rpm calibration.
20 19: 30: 39
(Day) (Hour) (Min) (Sec)
/9/ 27-Jul-18