Anda di halaman 1dari 35

WAVE

MALL ,
NOIDA

ALISHA BHUTADA - 05
AYUSHI KORDE -13
SHRADDHA JADHAV - 20
KAUSHIKI KAMBOJ - 21
INTRODUCTION
 LOCATION:- NOIDA
 SITE AREA:-8777sqm
 GROUNG COVERAGE:-
41%
 ENTRANCES-2(out of
which 1 is for parking)
 EXIT-1
 BUILT UP AREA:-
20,576sqm
 SETBACK:-7.5m ,REAR:-4m,FRONT:- 25m

 HEIGHT:-26m(G+6)
FEATURES

63 seater multi-branded Food Court


the 1770 + 34 Platinum Class seater Multiplex (5 theaters)
The anchor shop, Tata Westside spread over two floors covers an area of
14,500 sq. ft.
AREA of 3,48,460 sq ft comprising of - 1,38,500 sq ft of Retail space
i. 12,000 sq ft of Night Club
ii. 93,000 sq ft for parking in 2 levels
iii. 1,04,360 sq ft of Food & Entertainment area
PARKING
LAYOUT
 Parking on lower GF and
basement -2 level
 Total parking area = 4700 sq m
 Parking area = 23% Built – up
area
 Total no of car parking = 110 on
lower GF & -2 basement  For parking spaces in basements and upper floors,
 Total parking area = 4700 sq m at least two ramps of minimum 3.6m width or one
ramp of minimum 5.4m width and adequate slope 1
 Parking should be 60% of built –
in 8 shall be provided. Such ramps shall not be
up area acc to AP bylaws
allowed in mandatory setbacks including building
 Multi-level (allowed for plots line, however they may be permitted in the side and
750sq.m and above only) AP rear setbacks after leaving minimum 7m of setback
bylaws for movement of fire-fighting vehicles (AP Bylaws )
AREA STATEMENT
AREA STATEMENT
CIRCULATION
CIRCULATION

Follows a linear hierarchy


2 capsule lifts , 2 escalators , 5 staircases
3m wide corridors
3m wide staircases (2 nos)
2.5m wide staircase (2 nos)
1.5m staircase (1 no)
Atrium : 640 sq m
The main staircase and fire escape staircase shall be continuous from ground
floor to the terrace level.( AP Bylaws )
FIRE BY-LAWS (AP)

For building more than 24m in height, access to main staircase shall be through a
lobby created by double door of half an hour fire rating. One of the doors will be
fixed in the wall of the staircase and other after the lobby

Fire escape stairs shall have straight flight not less than 125cm wide with 25cm
treads and risers not more than 19cm and the number of risers shall be limited to
16 per flight
LOWER GROUND FLOOR
FOOD COURT AT
THE BOTTOM OF
THE ATRIUM

Common area provided in adequate


amount so that any visitor can have
visual access to the mall ; and can
have a blue-print idea of the
space,making ot easier for them to
move around
LOWER GROUND FLOOR
GROUND FLOOR

 Main floor makes or breaks the


motive of the visitor
 Characterized by huge open
area ( acting as a buffer
between the exterior and
interior )
 Alleviates sudden transition
which often is disorienting
 Toilets not provided on this
floor : not a good planning
decision
FIRST FLOOR
( UPPER GROUND FLOOR )
FIRST FLOOR
Main element of attraction should be there but sole importance
should not be given(anchor store)
Spaces designed are of optimum efficiency as maximum area is
chalked out for leasing or for tenants
Each space should have an equal access to the crowd and should
be in their immediate visual reach
Anchor stores to be positioned in a manner where it is away from
immediate reach but it should be followed in order to allow
smaller shops to survive
SECOND FLOOR

 Consists of similar
spaces as to maintain
the flow of shoppers
 Occasional provision for
eateries provided
 Segregation of public
areas and service areas
done properly
THIRD FLOOR

 Break in the flow of


spaces
 Consists of spaces of
different typologies : to
ensure break in the
monotony of the
shopping experience
 Rooms backed up with
proper emergency
facilities
FOURTH FLOOR

 3 theaters,1 common
lobby for theaters
 Any place of mass
gathering requires a
temporary buffer zone
so as to avoid any sort
of rampage or
confusion
FIFTH FLOOR
SIXTH FLOOR
MULTIPLEX

 3rd and 6th floor


 Connected by staircase , lifts ,
escalators
 All multiplexes connected with a
common corridor
 Common lobby for both
multiplexes
 Adequate no of toilets not
provided
 No toilets for differently
abled
 Entrances and exits placed
according to levels to
manage traffic flow during
peak hours
SERVICES
MATERIALS

 Contemporary look maintained


with the use of currently trending
materials such as aluminium
composite panels and glass
facades
 The entrance lobby and atrium
have been covered with fiber
glass,which allows light to
penetrate,but covers up the area
efficiently,and reduces the use of
artificial lighting
 To make it more energy efficient :
can use sensory lighting system
ACP Pros and Cons

 It is a very economical cladding material as compared to other options available in the


market.
 It is a very rigid, durable and strong material although it is very light in weight.
 The application method is very easy and hassle free. The material is readily available in
standard sizes which make the transportation of material on site very simple.
 It is unbreakable, stain resistant and weather resistant.
 They are available in numerous colors and finishes.

The main disadvantage is that:

 They are susceptible to dents during storms and hurricanes.


 The joints have to be carefully sealed and adequate water proofing has to be done so that
there is no water penetration into the building during the rains.
THANK YOU!

Anda mungkin juga menyukai