Anda di halaman 1dari 7

58

DITRICT COLLING SYSTEM

District Cooling could be simply defined a:-

• A centralized cooling plant that serve multiply buildings.


• A centralized cooling plant that is designed as a utility.
• A centralized and operated for maximum life- usually 25 years
or more.
• A centralized cooling plant that I designed to operate at
maximum efficient at all time.
76

• A centralized plant that is designed for


flexibility in operation.
• A centralized cooling plant that is deigned to
make full use of the operation /consumers
that it serves.
• A centralized plant that I operated by an
independent organization that operates,
maintains, and charges consumers for the
energy that is CONSUMED.
78

In our minds, unless all of these parameters


are met, a centralized cooling plant cannot
de classified as a district cooling plant
unless all of the above criteria are met. The
operation must be classified a a utility
operator and must be responsible to its
consumers, the community and the
environment.
Similar organization in Dubai are – EMPOWER,
Tabreed, and Palm District cooling.
80

How is District Cooling different


from a “Central Cooling plant”?
A Central plant is not much
different that a district plant. In
fact, the basic equipment is the
same. The difference lie in the
definition of a District Cooling
plant. The following is a list of
some of the basic differences
between the two systems.
82

CENTRAL PLANT DISTRICT COOLING PLAN


• It is operated by the owner of • Operated by a company that is
the building or the developer. certified to be a utility provider.
• It serves single building or • Serves large district with many
small group of buildings known buildings with many examples.
as campus. • All consumer connections are
• The connections to buildings metered.
are not metered. • Designed to operate efficiently,
• Designed to operate efficiently and cost effective from a capital
capital investment is usually investment perspective. These
not a great concern for the plant plants are designed to minimize
itself. The capital is concern for operational costs and hence
the entire development. max. profitability.
84

• Deigned to be reliable usually a • Designed usually with a higher


ingle point of failure from the degree of reliability and include
power supply and return feeds, implementation such as:-
etc. i) Networked chilled water
• Generally there plants utilize supplies.
electricity as their main source ii) Multiple electrical feeds.
of energy. iii) Industrial grade equipment
for control and operation.
iv) Distributed cooling plants.
• Deferent technologies are
available for these plants:
i) Gas fired engine driven
chillers.
ii) Absorption chillers.
86

It utilize municipal These plants can be


domestic water for designed for use with:
cooling tower heat of •Treated sewage effluent.
rejection. •Sea water
•Ground water.

These plants are Designed by


generally designed by professionals that are
the engineers that design experienced in the district
the buildings. cooling field.

Anda mungkin juga menyukai