Introduction
Tray Spacing
Tray spacing is the distance between two trays.
The overall height of the column will depend on the plate spacing. The spacing
chosen will depend on the column diameter and operating conditions.
Sufficient space must be provided for tray cleaning and repair.
From these considerations,
The minimum tray spacing is about 12 in (30 cm) for column diameter less
than 5 ft,
(150cm) and 18 in (45 cm) for a column diameter greater than10 ft (300
cm).
In general, it is best to keep trays pacing to a minimum, which is often the most
economical.
Downcomer Area
Passage of liquid from the top tray to the bottom of tray occurs via
downcomers. Downcomers are conduits having circular, segmental, or
rectangular cross sections that convey liquid from upper tray to a lower tray
in a distillation column.
The downcomer area at the top is sized such that the velocity of the
ascending vapour bubbles exceeds the down flow velocity of the liquid
. The size is related to the stability of the froth in the downcomer and
determined by the residence time required for achieving the separation of the
two-phase mixture
. For non foamig systems, such as lower alcohols, a residence time of 3 sec is
sufficient, whereas for extremely high foaming systems such as caustic
regenerators, 9 s is required.
To prevent the liquid coming off the bubbling area from splashing against the
column wall, the minimum width is 5 in (12.7 cm). Also, the minimum side
chord length should be 60% of the column diameter.
This is required to maintain good liquid distribution on the tray
.the downcomer area at the bottom should be about 60% of that at the
top.
It should be noted that the downcomer area occupies only a small fraction of
the cross-sectional area.
Column Diameter
The column diameter can be calculated once the tray spacing and
downcomer area have been specified.
The Fair correlation, based on the Souders and Brown criterion, is
recommended by most designers. The vapour flooding velocity can be
calculated from eqn
Knowing U and the total vapour flow rate, the column diameter can
be calculated by assuming that the column will be operated at a
lower vapour velocity
Number of Flow Passes
The number of flow passes is set to allow the tray to operate at a weir
loading that does not result in excessive weir crest.
The weir loading can be calculated once the column diameter and the
downcomer area are determined.
The optimum weir loading is 4-6 US gallons per minute and the maximum
loading is about 20.
Downcomer choking, which causes liquid build-up on the tray, may occur if
the maximum value is exceeded. Increasing the number of flow passes provides
a solution to this problem.
Tray Geometry
The following parameters must be specified for tray design calculations.
Tray Thickness
The choice of material for the fabrication of trays is dependent mainly on
the corrosion properties of the process fluids.
In general, tray thickness is about gauge 10 (0.134 in; 3.40 mm) for carbon
steel and gauge 12 (0.109 in; 2.77 mm) for stainless steel.
Hole Diameter
Small holes with a diameter in the range of in(4.76-6.35 mm) give better
hydraulic and mass transfer performance than the large ones in the range of
(12.7-19.0 mm)
However, large-hole trays are cheaper and show more resistance to fouling.
Hole Area
The hole area is normally in the range of 5-16% of the bubbling area.
Lower hole area allows the tray tooperate at higher efficiency and turndown
ratio, but at the expense of higher pressure drop.
Hole areas below 5% are not used because the distance between holes
becomes excessive and liquid
channelling may occur.
On the other hand, if the hole areas are greater than 16%, signiRcant
weeping and entrainment may coexist .
Wier Design
Outlet weirs are used to control the froth height on the tray. For most
trays, the outlet weir height about 1-4 in (2.5-10 cm)
the downcomer clearance, where the liquid is discharged from the bottom of
the downcomer onto the tray below, should be 0.5 in (1.25 cm) smaller
than the outlet weir height to ensure a positive downcomer seal.