Setting of PASOLINK V3/V4 equipment

• If you want to use V3 or V4 type of equipment for LAN entry point in a configuration,
you must use the V3.1 NSC, which is equipped with its extensional Ethernet card. This
extensional card is indicated with a red frame in the picture.

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Downloading the configuration file for the
equipment
• You do not have to make a configuration file for the equipment with NetConfigTool.
You only have to download the proper settings from the identification window of the
network element in the SuperGuard+ software.
• First of all, you have to connect to the equipment via its LA port.

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
How to access the Identification window-1
• Then you have to clck on the element, in order to access the NE view.
• From here you can access the Identification window, by clcking on the identificiation button.

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
How to access the Identification window-2
• You are able to set here the local
address, mask and port of the card.
You can also set here the remote
address of the card (this is the
address of the management PC).
You have to set the address of the
gateway, if you do not connect the
PC directly to the element.
• After the proper settings, you can
download them to the element, by
clicking on the Download button.

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Accessing the network with SuperGuard+ -2.
• In the case of V4 equipment, you have two possibilities, if you want to reach one element via LAN:
– You can use a crossed LAN cable, if you are connecting directly your PC to the element, or
you can use a straight LAN cable, if there is/are other element(s) in the network between
your PC and the element.
In these cases, you have to use the NMS LAN port of the equipment (marked with a red
frame).

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Accessing the network with SuperGuard+ -3.
• In the case of V4 equipment, the other possibility is to use the NMS/RA port of the equipment to
access it via LAN, with a cable, which has a DSUB-15 connector from the equipment side, and an
RJ-45 type connector from the LAn side.
• In the case of V3 equiment, there is only one possibility to use (because the V3 equipment does
not have an NMS LAN port): the NMS/RA port of the equipment.
• The pin assignment for these cables are described on the next slides.

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Station A Station B

PASOLINK PASOLINK
V4 V4

NMS LAN Port

8 pin RJ-45 (plug 8 pin RJ-45 (plug


RJ-45 GLCT
1 TX+
2 TX-
(LAN PC (GLCT) (LAN port) PASOLINK
3 RX+ port) NMS LAN port
4

NMS LAN port – GLCT


5 1 1 RJ-45
6 RX- 2 2 1 RX+
7 3 3 2 RX-
8
9
(PC) connection 4
5
4
5
3
4
TX+

6 6 5
7 7 6 TX-
8 8 7
8
9

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Station A Station B

PASOLINK PASOLINK Note: In case


V4 V4 of LAN-using:
Pin1, Pin 9:
NMS port NoConnect
(DSUB-15)
P0-entering point, P1
leaving point, P2
leaving point
8 pin RJ-45 (plug 15pin(M)

PASOLINK
GLCT PC (GLCT) (LAN port) NMS port (DSUB-15) RJ-45/DSUB-15
RJ-45 (LAN 1 1 P0_TX
1 TX+ 1
2 TX-
port) 2 2 2 TX+
3 3 3 TX-
3 RX+
4 P1_TX
NMS/RA port – GLCT 4 4
4
5 5 5 RX+
5
6 6 6 RX-
6 RX-
7
8
(PC) connection 7
8
7
8
7
8
GND
P1_RX
9 9 P0_RX
10 10 TXa
11 11 TXb
12 12 P2_TX
13 13 RXa
14 14 RXb
15 15 P2_RX
Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Station A Station B

PASOLINK PASOLINK Note: In case


V3 V3 of LAN-using:
Pin1, Pin 9:
NMS port NoConnect
(DSUB-15)
P0-entering point, P1
leaving point, P2
leaving point
8 pin RJ-45 (plug 15pin(M)

GLCT PASOLINK
PC (GLCT) (LAN port) NMS port (DSUB-15)
RJ-45 (LAN RJ-45/DSUB-15
1 TX+ 1 1 1 P0_TX
2 TX-
port) 2 2 TX+
NMS/RA port –
2
3 RX+ 3 3 3 TX-
4 4 4 4 RX-
5
6 RX- GLCT (PC) 5
6
5
6
5
6
RX+

7 7 7 7 GND
8 connection 8 8
9
8
9
P1_RX
P0_RX
10 10 TXa
11 11 TXb
12 12 P2_TX
13 13 RXa
14 14 RXb
15 15 P2_RX

Linecom Ltd.
H-1142 Budapest
Accessing the network with SuperGuard+ -
1. (LAN), Port IP assigning

Station A Station B

1.2 1.3
PASOLINK V3/V4 PASOLINK V3/V4

LAN Port:
192.168.1.240

IP address: 192.168.1.80
Gateway: 192.168.1.240
LAN cable

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Accessing the network with the SuperGuard+ via
(LAN)-Gateway setting

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Accessing the network with the SuperGuard+ via (LAN)- 1.,
communication ports

1. 2.

3.

1., You have to select „LAN” from the


possibilities at the settings of the
communication ports.
2., Then you have to enter the
appropriate port.
3., The result will appear (in this
example, LAN 10000)
Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Accessing the network with the SuperGuard+ via LAN- 2., NSC
IP mapping
After the settings of the communication ports, you have to access the NSC IP mapping tab
from the Settings->Network menu. You have to select here the proper serial address (the
address of the entry point).

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Accessing the network with the SuperGuard+ via LAN- 3., NSC
address

You have to set the address to „used”, then you have to select the UDP port, and enter the
proper IP address. After this, you are able to ping the element.
In this example, if you want to use only one card for LAN entry point,( which is a 3.1 ver.
Card, equipped with LAN extensionla card), and the other card is serial, the other card’s
address has to be within the 1.0-1.15 address range (excluding address 1.2).

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.
Accessing the network with the SuperGuard+ via LAN- 4.,
search nodes

If you search for the elements by their serial If you move the cursor on the
addresses, you can find them. address, you can check the settings
of the IP mapping.

Linecom Ltd.
H-1142 Budapest
Ungvár u. 64-66.

Anda mungkin juga menyukai