Anda di halaman 1dari 66

Nokia Siemens Networks

Flexi Multiradio Base Station

For internal use only


1 © Nokia Siemens Networks Multi Radio Overview/Ajay Kumar/Version 1.0
Migrating to Flexi Multiradio BTS

Flexi Multiradio BTS offers highest capacity, smallest weight and dimensions and
features three technologies in one radio module enabling smooth evolution to future
technologies
For internal use only
2 © Nokia Siemens Networks
Flexi Multi Radio BTS

For internal use only


3 © Nokia Siemens Networks Node:B Overview/Ajay Kumar/Version 1.0
Changes from flexi BTS

.
Flexi Multiradio brings the following changes when compared to Flexi EDGE
Base Station:-

The radio technology is changed from single carrier power amplifiers to multi
carrier power amplifiers. No external combiners are needed to combine the
different TRX outputs to a common antenna line.

Baseband processing is now centralized to the system module instead of


distributed to the radio modules as in Flexi EDGE BTS.

The interconnection between the system module and the radio module is
changed from Ethernet based electrical connection as in the Flexi EDGE BTS
to optical OBSAI connection as in Flexi WCDMA BTS. Thus Flexi Multiradio
Supports Feederless sites without optical optional converter modules.

For internal use only


4 © Nokia Siemens Networks
Multi Radio BTS

Flexi Multi Radio BTS: is a base transceiver station that is part of the Nokia
Siemens Networks Flexi BTS platform for GSM/EDGE, WCDMA, and LTE
networks. It is a multi radio or multicarrier BTS that can use all these network
technologies either in dedicated or concurrent mode of operation.
• The Flexi Multiradio GSM/EDGE System Module provides baseband capacity
for 18 or 36 GSM/EDGE TRXs depending on the version (ESMB or ESMC
respectively).
• There are 3 radio branches in one Flexi Multiradio Radio Frequency module
(FXxx). The TRX capacity of Flexi Multiradio BTS can be modified based on
the traffic by increasing or decreasing the number of TRXs within a Radio
Module branch, or by increasing the number of radio modules. Each radio
module branch supports up to 6 GSM/EDGE TRXs.
• The Radio module can be split into separate cells for multi-operator BTS.
• Flexi Multiradio modules can be installed on a mast or a pole reducing the
antenna feeder line length and thus increases the RF performance.

For internal use only


5 © Nokia Siemens Networks Multi Radio Overview/Ajay Kumar/Version 1.0
Flexi Multiradio BTS Architecture

Flexi Multiradio BTS is a Multiradio BTS capable for GSM/EDGE,


WCDMA and LTE dedicated or concurrent operation

For internal use only


6 © Nokia Siemens Networks
WCDMA/LTE specific configurations

The existing WCDMA and LTE configurations are supported.


WCDMA: Up to 4+4+4 (20MHz) in 900, 1800 and 1900 MHz band and 3/3/3
(15MHz) in 850 band.
LTE Bandwidth: 1.4/3/5/10/15/20 Mhz

Concurrent mode Configurations

Multiradio BTS can be concurrently used in various configurations. Also any


of the supported radio technologies can be used alone. Both 3-sector
RFM and RRH support GSM/EDGE, WCDMA and LTE simultaneously.
Following configurations are possible in concurrent mode:-
Up to 555 GSM+5MHz LTE or 1 WCDMA carrier
Up to 444 GSM+10MHz LTE or 2 WCDMA carriers
Up to 222 GSM +10MHz LTE+1WCDMA carrier
Up to 15MHz LTE and 2 GSM/EDGE TRXs or 1 WCDMA carrier (Supported
from March 2011)

For internal use only


7 © Nokia Siemens Networks
Key Features
Multicarrier radios for various frequency bands, capable to support up to 6
GSM/EDGE carriers in GSM dedicated mode, up to 4 WCDMA carriers in
WCDMA dedicated mode and up to 20MHz LTE carrier in LTE dedicated
mode with one radio branch. In concurrent mode of operation,
combination of all three radio technologies is supported with single radio
branch.

Radio module (RFM) capable to serve 3 sectors with Multicarrier radios of up


to 60W /80Woutput power/branch.

Flexi Multimode System Module supporting up to 750CE in WCDMA or LTE


3 cells@20MHz each with MIMO

Cost optimized GSM/EDGE configuration supporting up to 6 sectors with 36


carriers maximum BTS configuration (one BCF object).

For internal use only


8 © Nokia Siemens Networks
FXEA/FXEB/FXDJ FSEC
ESMB/ESMC

Product overview
FPKA FSES

FSFO
FPIA
EMHA

FMHA
FOSB
FMFA
For internal use only
9 © Nokia Siemens Networks Presentation / Author / Date
Dimensions and Weight

For internal use only


10 © Nokia Siemens Networks
System Module

For internal use only


11 © Nokia Siemens Networks Multi Radio Overview/Ajay Kumar/Version 1.0
Flexi EDGE 18/36 TRX System Module
Construction and Interfaces
Synch Synch
Q1 FPA Optical RP3 01 out in EAC LMP

Power input
3 HU PWR PWR PWR PWR PWR

Ground Transmission PIU Status and Power LED

• 4 optical SFPs. OBSAI RP3-01 interface (3Gbps). (3 for RF modules, 1 for 3G/LTE system
module connection or ESMB/ESMC chaining or alternatively all 4 for RF modules)
• 48VDC BTS power input terminals
• 5 Power distribution I/Fs (4 for co-located RFMs, and 1 extra for any additional modules)
• A slot for Integrated transport sub-module (various interface options available)
• Ports for Power Module Alarms, Local Management and Q1
• External Alarm Control port with 12 inputs and 6 outputs, or connectivity to EAC Ext.
Module
• Two ports for external synch. input or synch. extension to other co located base stations
• Status-LED, Power LED and Power Push Button
• Grounding terminal

For internal use only


12 © Nokia Siemens Networks
Flexi EDGE 18/36 TRX System Module
The operating power can be supplied to the radios from ESMx. It has
capability to distribute the 48VDC power for up to 4 radios and one
auxiliary device. The Flexi WCDMA system module can distribute the
power for more radios in concurrent configurations. ESMx has an AUX
power output (40.5…57 VDC, 5A) for the site equipment like MWR ID
units etc
ESMB/ESMC has 12 integrated alarm inputs and 6 control outputs. The
number of the external alarm inputs can be increased to 24 using optional
Flexi alarm extension module (FSEB). The radios have also External
alarm and control interfaces for Feederless or distributed site applications
It also has an Element Manager Interface to connect the BTS to a Laptop
computer, Flexi power alarm Interface which provides a Nokia Siemens
Networks specific power alarm interface for the integrated power modules
(FPMA, FPDA, MIBBU, iPSU). And a Q1 interface for managing legacy
Nokia Siemens Networks equipment

For internal use only


13 © Nokia Siemens Networks
System Module

For internal use only


14 © Nokia Siemens Networks
System Module

For internal use only


15 © Nokia Siemens Networks
ESMx integrated transmission

Flexi Multiradio BTS GSM/EDGE system module uses the same transport
options as with existing Flexi EDGE BTS. The transport interface comes
in six different types of plug in units inserted into the system module
(ESMx):

FIEA : 8*E1 asymmetrical

FIPA : 8*E1/T1 symmetrical

FIFA: 2*Flexbus TNC-type 50 Ω coaxial connector

FIQA: 1*SFP port, 2* Fast Ethernet, 4*E1/T1 symmetrical

FIYA : 1*SFP port, 2* Fast Ethernet; 4*E1/T1 asymmetrical

FIQB :1*SFP port, 2* Fast Ethernet, 4*E1/T1 symmetrical

For internal use only


16 © Nokia Siemens Networks
Transmission Module FIQB

For internal use only


17 © Nokia Siemens Networks
RF Module

For internal use only


18 © Nokia Siemens Networks Multi Radio Overview/Ajay Kumar/Version 1.0
Flexi Multi Radio 3-Sector RF Module Triple 70W(FXEA ,FXDJ)
Sector 3 Sector 2 Sector 1 RX Div for
Div Rx Tx/Rx Div Rx Tx/Rx Div Rx Tx/Rx Co-siting

• < 25 kg
• 3 height units
• IP65
• -35 to +55 °C

• 1 RF module for 3-sector site, 18 carrier (3x6) capacity with integrated Duplex Filters
• 3 x 60W at antenna connector
• Available in 850 MHz, 900 MHz full band, J band, 1800 MHz and 1900 MHz band
• Active bandwidth software tunable for 20MHz@ 900*/1800/1900 MHz, and 15MHz@850MHz
• 3 RP3 01 OBSAI Interfaces, for System Module connectivity and RFM chaining
• 3 TX/RX Antenna Interfaces, 3 RX Diversity Antenna Interfaces** (see notes)
• 3 RX outputs for diversity sharing with co-sited BTS (Ultrasite/Flexi EDGE/BS2xx)
• Support for AISG 2.0 (only for 3G), Bias-T’s and VSWR measurement
• 48V DC input

* 12.5MHz for 900 J Band


For internal use only
19 © Nokia Siemens Networks
Triple RF Module port details 70W

For internal use only


20 © Nokia Siemens Networks Multi Radio Overview/Ajay Kumar/Version 1.0
RF Module front panel description

For internal use only


21 © Nokia Siemens Networks
RF Module front panel description

For internal use only


22 © Nokia Siemens Networks
Flexi Multiradio 3-Sector RF Module Triple 70W
Flexi Multi Radio 3-Sector RF Module Triple 90W(FXEB

• < 25 kg
• 3 height units
• IP65
• -35 to +55 °C

• 1 RF module for 3-sector site, 18 carrier (3x6) capacity with integrated Duplex Filters
• 3 x 80W at antenna connector
• Integrated DC line OVP, Class II rated to 5kA pulse (FXFB, FXDB/FXEB/FXFC)
• 3 RP3 01 OBSAI Interfaces, for System Module connectivity and RFM chaining
• 3 TX/RX Antenna Interfaces, 3 RX Diversity Antenna Interfaces** (see notes)
• 3 RX outputs for diversity sharing with co-sited BTS (Ultrasite/Flexi EDGE/BS2xx)
• Support for AISG 2.0 (only for 3G), Bias-T’s and VSWR measurement
• External RET interface 1 piece in FXxB
• 48V DC input
RF Module front panel description 90W

For internal use only


25 © Nokia Siemens Networks
Contents of RF Module delivery (90W)
RF Configuration
RF Configurations with single RF Module
Cross polarized antennas
X
RM

Duplexer
TX
MCPA
LNA
RX main RXMC
• Up to 666 with 1 Radio Module

RX
LNA X
• 2 way diversity, 6 antenna RX div
ports/module
• 1 x Pol antenna per sector

Duplexer
TX
MCPA
• Output Power LNA
• 1/1/1 @ 60W per TRX RX main RXMC

• 2/2/2 @ 30W per TRX X

RX
LNA
RX div
• 3/3/3 @ 20W per TRX
• 4/4/4 @ 15W per TRX

Duplexer
TX
• 6/6/6 @ 10W per TRX MCPA
LNA
RX main RXMC

RX
LNA
RX div

Note: Asymmetric powers per TRX are also supported e.g,


4/4/4 with BCCH and 1 TCH TRX@20W and other 2 TCH
TRXs@10Weach RP3
For internal use only
28 © Nokia Siemens Networks
Power Requirement for Multi Radio Modules with MCB Ratings
Classic Solution with 70W RF Module
Classic Solution: RF Module is taking power from System Module:
Max Power: 839W+80W =919W MCB 32A x 1
Classic Solution with two RF module: RF Module is taking power from System Module:
Max Power: 839W+839W+80W =1758W MCB 63A x 1
Classic Solution with 90W RF Module
Classic Solution: RF Module is taking power from System Module:
Max Power: 1100W+80W =1180W MCB 40A x 1
Classic Solution with two RF module: RF Module is taking power from System Module:
Max Power: 1100W+1100W+80W =2280W MCB 80A x 1

Distributed Solution: RF module and System Module are separately given power from PP:
System Module: 80W= MCB 16A x 1
RFM (70W): 839 W MCB 32A x 1.
RFM (90W): 1100W MCB 32A x 1.
Distributed Solution with two RF module
System Module and 2RFM are separately given power from PP:
System Module: 80 W MCB 16A x 1
2 RF Module(70W): 2x839W=1678W MCB 32A X 2.
2 RF Module(90W): 2x1100W=2200W MCB 32A X 2.
Optional Item

For internal use only


30 © Nokia Siemens Networks Multi Radio Overview/Ajay Kumar/Version 1.0
FSES overview
• FSES is an over voltage protection device. FSES is used to protect Flexi Units in case of indirect lightning strike.
• FSES is used in DC input when the input line is more than 2 meters. This is the case in feeder less site solutions. Cabinet
installations or stack installations are not the main stream for FSES.
The FSES gives Class II (C, T2) protection for DC power feed and provides IP65 protection.
It is used in both ends of the long DC feeder line, but not at the input of a SystemModule.
FSES/C is used in LTE, WCDMA and GSM/EDGE
Protection level of FSES is 15kA
The Flexi System External OVP (FSES) delivery contains the following items:
• Flexi System External OVP (FSES) with a pre-installed power output and grounding
cable
• Plastic bag containing M5x8 screws (6150279) for fixing the FSES to a 3U casing

/
Flexi System External OVP (FSEC)
Flexi System External OVP (FSEC) protects Flexi Multi Radio sub-modules
against surge pulse(s) in power feeding lines
Flexi System External OVP (FSEC) wiring diagram

Cable shield

XCMK cable

To DCDB
Flexi Module Casing (EMHA)
Optional Flexi Module Casing (EMHA) is used to fix the modules to
floor, wall, or pole.
Flexi BTS Side Covers
Flexi BTS Side Covers are available as an optional item.
in the following figures:
Covers FMHA for 3 height units (3U)
Flexi Mounting Kit for Floor, Wall and Pole (FMFA)

Flexi BTS modules are installed on the floor, wall or pole using Flexi Mounting kit
for Floor, Wall and Pole (FMFA). The plinth is required in BTS site installations
without a cabinet and it provides grounding points for BTS and module grounding.
Flexi Power Cables
FPCA 472806A is a 2 m (6.6 ft) dual DC power cable with connectors and IP
seals on the System Module end. The other end is open for connecting to the 90 W
RF Module’s DC connector. The cable requires two available power output
Connectors on the System Module. The cable is used when 90 W RF Modules draw
DC power from a System Module and the total configured output power for all
branches is greater than 180 W. To minimize potential site work, consider future
Expansion when selecting DC cables.
Nokia Siemens Networks

Flexi Multiradio Base Station


Deployment Options

For internal use only


40 © Nokia Siemens Networks
Proposed solution for Implementation

• Swapping of Flexi BTS Indoor to Multiradio -


• Indoor Classic
• Indoor Distributed

• Swapping of Flexi BTS outdoor to Multiradio-


• Outdoor Classic
• Outdoor Distributed

• Swapping of Ultra BTS indoor to Multiradio –


• Indoor Classic
• Indoor Distributed

• Swapping of Ultra BTS outdoor to Multiradio –


• Outdoor Classic
• Outdoor Distributed

For internal use only


41 © Nokia Siemens Networks Presentation / Author / Date
Indoor Classic Solution

 System Module and RF Module Installed together

Requirement:

 Space Available inside 19” Rack (6U) or Floor/wall for System Module & RF Module.

 32 Amps MCB is required with 70W RFM and 40A MCB with 90W RFM

 Provisioning of 2 Hole with nut & bolt in IGB for System module and DDF grounding

 Space required for DDF mounting inside the shelter/cage near the existing Alarm panel

 Sufficient space required on Indoor cable trey for routing of Power, PCM, and
Grounding Cable.
LIGHTING ARRESTOR
NSN Flexi/Ultra EDGE BTS Indoor Site

ANTENNA

C ONNECTOR

GROUNDING
KIT
B US BAR

Towards Tower

C ANOPY
DDF
DCDB

EGB
DCDB
IGB

DOOR

NSN
F IU
Flexi
EDGE
P.P
BTS
S tep
Ladder

TOWER
GROUND
LIGHTING ARRESTOR
Indoor Classic – Existing 19” Rack

System Module and RF Module Installed in 19” Rack


System module connected with 32A/40A MCB from DCDB
RF Module connected with System Module
ANTENNA

CONNECTOR

GROUNDING
KIT
BUS BAR

Towards Tower

CANOPY
DDF
DCDB

E GB
DCDB
IGB
RF Module

Door

FIU
MR-System
Module Indoor
P.P

Step
Ladder

TOWER
GROUND
LIGHTING ARRESTOR
Indoor Classic – 19” Rack/ BTS cabinet

System Module and RF Module Installed in 19” Rack/BTS cabinet


System module connected with 32A/40A MCB from DCDB
R F Module connected with System Module
ANTENNA

CONNECTOR

GROUNDING
KIT
BUS BAR

Towards Tower

CANOPY
DDF
DCDB
EGB
DCDB
IGB

MR-System
Module Indoor RF Module
DOOR

FIU

19'' P.P
Rack
Step
Ladder

TOWER
GROUND
LIGHTING ARRESTOR Indoor Classic – Stack

System Module and RF Module Stack on floor


System module connected with 32A/40A MCB from DCDB
R F Module connected with System Module
ANTENNA

C ONNECTOR

GROUNDING
KIT
B US BAR

Towards Tower

C ANOPY
DDF
DCDB
EGB
DCDB
IGB

Door

F IU

R F Module P.P
M R-System
M odule Indoor S tep
Ladder

TOWER
GROUND
Multi Radio HW –Indoor Classical

S.No Code Product Description Qty Remarks

1 FXDJ Flexi 3 sector RF Module Triple 60W 900 (FXDJ) 1


Any one RF
module
2 FXEA FLEXI RF MODULE 1800 TRIPLE 60W (NA) 1 required as
per band and
3 FXEB FLEXI RF MODULE 1800 TRIPLE 80W 1 power

4 ESMB FLEXI EDGE 18 TRX SYSTEM MODULE 1

6 FIQB Transport Interface ( E1 + Ethernet) 1

7 FSAA Flexi System Alarm Cable 15m 1

8 FTCB OD CABLE RJ48C 120ohm 15M 1

9 FOSB Flexi optical SFP B 850nm 3G 200M 2

10 FSFO FSFO Flexi System Fiber Cable 2M 1

For internal use only


47 © Nokia Siemens Networks Presentation / Author / Date
Multi Radio Installation Material –Indoor Classic
sr no. Item Code Indoor Classic - Installation Material UNIT QTY
1 CS80021.96 M10 200MM THREADED BOLT NUT WASHERSMS PCS 4

2 CS80020.16 RS CABLE TIE 2.5X92 (50 Pcs) PKT 1


3 CS80020.17 RS CABLE TIE 4.8X186 BLACK(50PCS) PKT 1
4 CS80020.03 3RD GEN INDOOR LABLE SET PKT 1
5 CS80020.18 RS CABLE TIE 7.6X380 BLACK(50PCS) PKT 1
6 CS80021.61 COP. CAB. LUG 16MM2 M8(FLAT TYPE) PCS 8
7 CS80021.62 COP. CAB. LUG 16MM2 M10 PCS 2
8 CS80021.74 COP. CAB. LUG 16MM2 PIN TYPE PCS 2
9 CS80040.87 1/2in DIN F St-DIN M Rt angled 3Mtr PCS 6
10 CS80022.11 BUF 2/10, 22.5MM PITCH,5 WAY pcs 1
11 CS80024.61 LSA PLUS Disconnection Module 10 Pair PCS 2
12 CS80042.51 16 SQMM CU.FLEXIBLE GROUNDING CABLE Y/G M 15
13 CS80042.42 16 MM2 COPPER BLACK INSTALLATION CABLE M 10
14 CS80042.43 16 MM2 COPPER BLUE INSTALLATION CABLE M 10
15 CS80020.11 ROW CLA INST. BAR PCS 4
16 CS80019.88 WOOD SCREW NO. 8 X 40 - 20 NOS. SS PCS 1
17 CS80019.96 ROW CONNECTOR/TERMINAL 4-28MM WHITE PCS 20
18 CS80019.94 NYLON WASHER FOR M10 PCS 4
19 CS80019.74 RS INS.TAPE 15X10 M BLUE INDIA-1PC PCS 1
20 CS80019.73 RS INS.TAPE 15X10 M BLACK INDIA-1PC M 1
21 CS80019.76 RS INS.TAPE 15X10 M YELLOW INDIA-1PC PCS 1

For internal use only


48 © Nokia Siemens Networks Presentation / Author / Date
Indoor Distributed Solution
System Module Installed in shelter and RF Module on Tower Pole

Requirement:
Space Available inside 19” Rack (3U) or Floor/wall for System Module

 Pole is required for RF Module near to GSM Antenna with safe working area and zero
degree tilt

 Ensure pole diameter should be between (60mm-120mm) with a load bearing capacity of
25Kgs for RF Modules

 32 Amps MCB required for RFM & 16 Amps MCB is required System Module

Grounding termination availability on tower ensure tower should be properly grounded .

Provisioning of 2 Hole with nut & bolt in IGB for System module and DDF grounding

Space required for DDF mounting inside the shelter near the existing Alarm panel

Sufficient space required in cable trey for routing of Power, PCM, Optical and Grounding
Cable from shelter to tower top.
For internal use only
49 © Nokia Siemens Networks
LIGHTING ARRESTOR
Indoor Distributed – Existing 19” Rack

System Module Installed in Existing 19” Rack


System module connected with 16A MCB from DCDB
RF Module Installed on Tower pole
ANTENNA OVP installed bottom of RF Module
R F Module(70W) connected with 32A MCB from DCDB (Through FSES
OVP)
R F Module(90W) connected with 32A MCB from DCDB
RF Module

OVP

Towards Tower

CANOPY
DDF
DCDB
EGB
IGB
DCDB
MR-System
Module Indoor

DOOR

FIU

P.P

Step
Ladder

TOWER
GROUND
LIGHTING ARRESTOR

Indoor Distributed – 19” Rack/BTS cabinet

System Module Installed in 19” Rack/BTS Cabinet


System module connected with 16A MCB from DCDB
ANTENNA
RF Module Installed on Tower pole
OVP installed bottom of RF Module
R F Module(70W) connected with 32A MCB from DCDB (Through OVP)
R F Module(90W) connected with 32A MCB from DCDB
RF Module

OVP

Towards Tower

CANOPY
DDF
DCDB
EGB
DCDB
IGB

MR-System
Module Indoor
DOOR

FIU

19'' P.P
Rack
Step
Ladder

TOWER
GROUND
Indoor Distributed – Stack

System Module Stack on floor


ANTENNA
System module connected with 16A MCB from DCDB
RF Module Installed on Tower pole
OVP installed bottom of RF Module
RF Module R F Module(70W) connected with 32A MCB from DCDB (Through OVP)
R F Module(90W) connected with 32A MCB from DCDB
OVP

Towards Tower

CANOPY
DDF
DCDB
E GB
IGB
DCDB

DOOR

FIU

M R-Sy stem P.P


Step
M odule Indoor Lad der

OVP

TOWER
GROUND
Multi Radio HW –Indoor DBS
S.No Code Product Description Qty Remarks
Any one RF
2 FXEA FLEXI RF MODULE 1800 TRIPLE 60W (NA) 1 module required
as per band and
3 FXEB FLEXI RF MODULE 1800 TRIPLE 80W 1 power

4 ESMB FLEXI EDGE 18 TRX SYSTEM MODULE 1

5 FIQB Transport Interface ( E1 + Ethernet) 1

6 FMFA FLEXI MOUNTING KIT FLOOR/WALL/POLE 1

7 EMHA FLEXI EDGE MECHANICAL 3U UNIT 1

8 FSAA Flexi System Alarm Cable 15m 1

9 FMHA FLEXI SIDE COVER 3U 1

10 FTCB OD CABLE RJ48C 120ohm 15M 1

11 FPKA Flexi Pole Kit 2

12 FSES OVP (Over Voltage Protector) 1

13 FOSB Flexi optical SFP B 850nm 3G 200M 2

For internal use only


53 © Nokia Siemens Networks Presentation / Author / Date
Multi Radio Installation Material –Indoor DBS
sr no. Item Code Multi Radio Indoor DBS IM BOQ UNIT QTY
1 CS80021.96 M10 200MM THREADED BOLT NUT WASHERSMS PCS 4
2 CS80022.03 CABLE TIE 4,8X292 (50 PCS) OUTDOOR PKT 2
3 CS80020.17 RS CABLE TIE 4.8X186 BLACK(50PCS) PKT 1
4 CS80020.03 3RD GEN INDOOR LABLE SET PKT 1
5 CS80022.18 COPPER CABLE LUG 16MM2 M8 PCS 10
6 CS80056.25 COPPER CABLE LUG 16MM2 M10 PCS 2
7 CS80021.72 COP. CAB. LUG 16 MM2 PIN TYPE PCS 2
10 CS80040.97 1/2in DIN M St-DIN M Rt angled 5Mtr as applicable PCS 2
11 CS80038.38 1/2 in Jmper Din M/Din Rt angle M-7 mtr as applicable 4
12 CS80022.11 BUF 2/10, 22.5MM PITCH,5 WAY pcs 1
13 CS80024.61 LSA PLUS Disconnection Module 10 Pair PCS 2
14 CS80042.41 16 MM2 CU GROUNDING CABLE Y/G M 20
15 CS80023.51 16 MM2 COPPER BLACK INSTALLATION CABLE M 10
16 CS80040.07 16 mm2 copper Blue installation cable M 10
17 CS80020.11 ROW CLA INST. BAR PCS 4
18 CS80019.88 WOOD SCREW NO. 8 X 40 - 20 NOS. SS PCS 1
19 CS80019.96 ROW CONNECTOR/TERMINAL 4-28MM WHITE PCS 20
20 CS80019.94 NYLON WASHER FOR M10 PCS 4
21 CS80019.74 RS INS.TAPE 15X10 M BLUE INDIA-1PC PCS 1
22 CS80019.73 RS INS.TAPE 15X10 M BLACK INDIA-1PC M 1
23 CS80019.76 RS INS.TAPE 15X10 M YELLOW INDIA-1PC PCS 1
25 CS80043.29 2C/16 SQMM+2.5 SQMM XCMK POWER CABLE M 40
26 CS80030.97 Weather Proof Kit PCS 3

For internal use only


54 © Nokia Siemens Networks Presentation / Author / Date
LIGHTING ARRESTOR

NSN Flexi / Ultra BTS Outdoor Site

ANTENNA

CONNECTOR

GROUNDING
KIT
BUS BAR

Rectifier
Towards Tower Outdoor
19'' Rack
PIU Rack

Towards
Battery& SMPS Out
Cabinet Door
NSN
Flexi
EDGE/
Battery
Bank Ultra
BTS

Step
Ladder

TOWER
Outdoor Classic Solution

System Module and RF Module installed together

Requirement:

Space Available in outdoor 19” rack(6U)/ OD Foundation/ Pole( Tower leg)/wall for
System Module.

 32 Amps MCB is required with 70W RFM and 40A MCB with 90W RFM

 Provisioning of 2 Hole with nut & bolt in EGB for System module and DDF grounding

Space required for DDF mounting inside the cage near the existing Alarm panel

Space required on pole/wall near the system module for mounting OVP(FSEC)

For internal use only


56 © Nokia Siemens Networks
Outdoor Classic -Stack
ANTENNA
System Module and RF Module stack on OD Foundation
System Module and RF Module Installed on tower leg
System module connected with 32A/40A MCB from DCDB
(Through OVP)
OVP installed near System Module on pole/wall
R F Module connected with System Module
CONNECTOR

GROUNDING
KIT
BUS BAR

Rectifier
Towards Tower

PIU

Towards
Battery& SMPS
Cabinet

RF
Battery OVP
Module
Bank
MR- System
Module Outdoor

Step
Ladder

TOWER
LIGHTING ARRESTOR

Outdoor Classic – Pole(Tower leg)

System Module and RF Module Installed on tower leg


ANTENNA System module connected with 32A/40A MCB from DCDB
(Through OVP)
OVP installed near System Module on pole/wall
R F Module connected with System Module

CONNECTOR

GROUNDING
KIT
BUS BAR

Rectifier
Towards Tower

PIU

Towards
Battery& SMPS
Cabinet
OVP
RF Module

Battery
Bank
MR- System
Module Outdoor

Step
Ladder

TOWER
Multi Radio HW –Outdoor classic
S.No Code Product Description Qty Remarks

1 FXDJ Flexi 3 sector RF Module Triple 60W 900 (FXDJ) 1

Any one RF
2 FXEA FLEXI RF MODULE 1800 TRIPLE 60W 1 module required
as per band and
3 FXEB FLEXI RF MODULE 1800 TRIPLE 80W 1 power

4 ESMB ESMB FLEXI EDGE 18 TRX SYSTEM MODULE 1

5 FIQB FIQB - Transport Interface ( E1 + Ethernet) 1

6 EMHA EMHA FLEXI EDGE MECHANICAL 3U UNIT 2

7 FSAA FSAA Flexi System Alarm Cable 15m 1

8 FMHA FMHA FLEXI SIDE COVER 3U 2

10 FTCB FTCB OD CABLE RJ48C 120ohm 15M 1

11 FOSB Flexi optical SFP B 850nm 3G 200M 2

12 FSFO FSFO Flexi System Fiber Cable 2M 1

13 FSEC FSEC - OVP (Over Voltage Protector) 1

For internal use only


59 © Nokia Siemens Networks Presentation / Author / Date
Multi Radio Installation Material –Outdoor Classic
sr no. Item Code Multi Radio outdoor classic IM BOQ UNIT QTY
1 CS80021.93 ANCHOR BOLTS -M10 *75L PCS 4
2 CS80020.16 RS CABLE TIE 2.5X92 (50 Pcs) PKT 1
3 CS80022.03 CABLE TIE 4,8X292 (50 PCS) OUTDOOR PKT 1

4 CS80020.18 RS CABLE TIE 7.6X380 BLACK(50PCS) PKT 1


5 CS80020.03 3RD GEN INDOOR LABLE SET PKT 1
6 CS80022.22 COPPER CABLE LUG 16MM2 M10 FLAT PCS 2
7 CS80022.19 COPPER CABLE LUG 16MM2 M8 (FLAT) PCS 7
8 CS80021.75 COP. CAB. LUG 16MM2 PIN TYPE PCS 2
9 CS80040.87 1/2in DIN F St-DIN M Rt angled 3Mtr PCS 6
10 CS80024.48 A-30 Box 3 way BUF and lock PCS 1
11 CS80024.61 LSA PLUS Disconnection Module 10 Pair PCS 2
12 CS80042.64 16 SQMM CU FLEXIBLE GROUNDING CABLE Y/G M 15
13 CS80043.29 2C/16 SQMM+2.5 SQMM XCMK POWER CABLE M 18
14 CS80019.74 RS INS.TAPE 15X10 M BLUE INDIA-1PC PCS 1
15 CS80019.73 RS INS.TAPE 15X10 M BLACK INDIA-1PC M 1
16 CS80019.76 RS INS.TAPE 15X10 M YELLOW INDIA-1PC PCS 1
17 CS80042.48 STEEL REINFORCE PVC FLEX CONDUIT PIPE PCS 18

18 CS80030.97 Weather Proof Kit PCS 3

For internal use only


60 © Nokia Siemens Networks Presentation / Author / Date
Outdoor Distributed Solution
System Module Installed in Outdoor and RF Module on Tower Pole

Requirement:

Space Available in Outdoor 19” Rack(3U)/ OD Foundation / Pole( Tower leg)/wall for System Module.

 Pole is required for RF Module near to GSM Antenna with safe working area and zero degree tilt

 Ensure pole diameter should be between (60mm-120mm) with a load bearing capacity of 25Kgs for RF
Modules

 32 Amps MCB required for RFM & 16 Amps MCB is required System Module

Grounding termination availability on tower ensure tower should be properly grounded

Provisioning of 2 Hole with nut & bolt in EGB for System module and DDF grounding

Space required for DDF mounting inside the cage near the existing Alarm panel

Sufficient space required on cable trey for routing of Power, PCM, Optical and Grounding Cable from
shelter to tower top.

Space required on pole/wall near the system module for mounting OVP(FSEC)
For internal use only
61 © Nokia Siemens Networks
LIGHTING ARRESTOR
Outdoor Distributed – 19” Rack

System Module Installed in OD 19” Rack


System module connected with 16A MCB from DCDB
RF Module Installed on Tower pole
ANTENNA OVP Installed bottom of RF Module
R F Module(70W) connected with 32A MCB from DCDB (Through OVP)
R F Module(90W) connected with 32A MCB from DCDB
OVP installed near System Module on pole/wall
RF Module

OVP

Rectifier Outdoor
Towards Tower
OVP 19'' Rack
PIU R ack
MR-System
Module Outdoor

Battery
Bank

Step
Ladder

TOWER
GROUND
LIGHTING ARRESTOR Outdoor Distributed – Pole( Tower Leg)

System Module Installed in Pole ( Tower leg)


System module connected with 16A MCB from DCDB
RF Module Installed on Tower pole
ANTENNA OVP Installed bottom of RF Module
R F Module(70W) connected with 32A MCB from DCDB (Through OVP)
R F Module(90W) connected with 32A MCB from DCDB
RF Module
OVP installed near System Module on pole/wall

OVP

Rectifier Outdoor
Towards Tower
19'' Rack
PIU R ack

MR- System
Battery
Module Outdoor
Bank

Step
Ladder

TOWER
GROUND
LIGHTING ARRESTOR

Outdoor Distributed – Stack

System Module stack on OD Foundation


System module connected with 16A MCB from DCDB
ANTENNA RF Module Installed on Tower pole
OVP Installed bottom of RF Module
R F Module(70W) connected with 32A MCB from DCDB (Through OVP)
R F Module(90W) connected with 32A MCB from DCDB
RF Module
OVP installed near System Module on pole/wall

OVP

Rectifier
Towards Tower

PIU

Battery MR-System
Bank Module Indoor
OVP

Step
Ladder

TOWER
GROUND
LIGHTING ARRESTOR

Outdoor Distributed – Wall

System Module Installed on wall


System module connected with 16A MCB from DCDB
RF Module Installed on Tower pole
ANTENNA
OVP Installed bottom of RF Module
R F Module(70W) connected with 32A MCB from DCDB (Through OVP)
R F Module(90W) connected with 32A MCB from DCDB
RF Module OVP installed near System Module on pole/wall

OVP

Rectifier Outdoor
Towards Tower
1 9'' Rack

PIU

M R- System
Battery
M odule Outdoor
Bank

OVP Step
Lad der

TOWER
GROUND
Multi Radio HW –Outdoor DBS
S.No Code Product Description Qty Remarks

1 FXDJ Flexi 3 sector RF Module Triple 60W 900 (FXDJ) 1


Any one RF
2 FXEA FLEXI RF MODULE 1800 TRIPLE 60W 1 module required
as per band and
3 FXEB FLEXI RF MODULE 1800 TRIPLE 80W 1 power

4 ESMB ESMB FLEXI EDGE 18 TRX SYSTEM MODULE 1

5 FIQB FIQB - Transport Interface ( E1 + Ethernet) 1

6 FMFA FMFA FLEXI MOUNTING KIT FLOOR/WALL/POLE 1

7 EMHA EMHA FLEXI EDGE MECHANICAL 3U UNIT 2

8 FSAA FSAA Flexi System Alarm Cable 15m 1

9 FMHA FMHA FLEXI SIDE COVER 3U 2

10 FTCB FTCB OD CABLE RJ48C 120ohm 15M 1

11 FPKA FPKA Flexi Pole Kit 2

12 FSES OVP (Over Voltage Protector) 1

13 FOSB Flexi optical SFP B 850nm 3G 200M 2

14 FIPA Flexi Pole Installation Kit 1

15 FSEC FSEC - OVP (Over Voltage Protector) 1

For internal use only


66 © Nokia Siemens Networks
Multi Radio Installation Material –Outdoor DBS
sr no. Item Code Multi Radio outdoor DBS IM BOQ UNIT QTY
1 CS80021.93 ANCHOR BOLTS -M10 *75L PCS 4
2 CS80020.16 RS CABLE TIE 2.5X92 (50 Pcs) PKT 1

3 CS80022.03 CABLE TIE 4,8X292 (50 PCS) OUTDOOR PKT 2


4 CS80020.03 3RD GEN INDOOR LABLE SET PKT 1
5 CS80022.18 COPPER CABLE LUG 16MM2 M8 PCS 9
6 CS80056.25 COPPER CABLE LUG 16MM2 M10 PCS 2
7 CS80021.72 COP. CAB. LUG 16 MM2 PIN TYPE PCS 4
10 CS80040.97 1/2in DIN M St-DIN M Rt angled 5Mtr PCS 2
11 CS80038.38 1/2 in Jmper Din M/Din Rt angle M-7 mtr pcs 4
12 CS80024.48 A-30 Box 3 way BUF and lock PCS 1
13 CS80024.61 LSA PLUS Disconnection Module 10 Pair PCS 2
14 CS80042.41 16 MM2 CU GROUNDING CABLE Y/G M 15
15 CS80030.73 2C/16 SQMM+ 2.5 SQMM XCMK POWER CABLE M 18
16 CS80019.74 RS INS.TAPE 15X10 M BLUE INDIA-1PC PCS 1
17 CS80019.73 RS INS.TAPE 15X10 M BLACK INDIA-1PC M 1
18 CS80019.76 RS INS.TAPE 15X10 M YELLOW INDIA-1PC PCS 1
19 CS80042.48 STEEL REINFORCE PVC FLEX CONDUIT PIPE PCS 18
22 CS80030.97 Weather Proof Kit PCS 3

For internal use only


67 © Nokia Siemens Networks Presentation / Author / Date
Thanks

Anda mungkin juga menyukai