Installation of Safety Duct Plug

A Safety barrier against falling debris inside


the ducts/cyclones

Kymore Cement Works


0
ACC Kymore Cement Works 01/10/2012
234460-36 SCM 2 AG 21Oct08.ppt
About Safety Duct Plug

The Safety DuctPlug is a very tough assembly, both abrasion


and puncture resistant. While its primary function is to serve as a
temporary safety barrier against falling debris to protect those
working below, it is not intended to be "load bearing”.

If material falls onto the Safety DuctPlug from above, especially
any substantial amount, workers should be immediately
evacuated from underneath and then once everyone is safely out
of the way, the Safety DuctPlug should be gradually emptied of
air sufficient to allow the debris to fall harmlessly below. The
Safety DuctPlug can then be re-inflated quickly and work safely
resumed.
1
ACC Kymore Cement Works 01/10/2012
234460-36 SCM 2 AG 21Oct08.ppt
Demonstration in open area before installation

2
ACC Kymore Cement Works 01/10/2012
234460-36 SCM 2 AG 21Oct08.ppt
Safety Duct Plug – Director Plant with Kymore
Team

3
ACC Kymore Cement Works 01/10/2012
234460-36 SCM 2 AG 21Oct08.ppt
How to use it……

The device is intended to be connected to the compressed air


supply of the plant in which it is used

Only 5 psi internal pressure is required to fully inflate and hold the
Duct Plug in place. Note that the Duct Plug does not have to be
inflated to the point of being rigid to be effective - only inflate it
sufficiently to hold it in place. The air supply should be left attached
in case additional air is required.

When you are ready to remove the Safety Duct Plug, simply
disconnect the air supply, release the air release (dump) valve, and
allow the Duct Plug to deflate sufficiently in order to remove it from
its location. Once removed, fully deflate it and fold it up for
storage.

CAUTION: DO NOT OVER INFLATE. Damage could


result to the unit.
4
ACC Kymore Cement Works 01/10/2012
234460-36 SCM 2 AG 21Oct08.ppt
Inspection of Safety Balloon before

5
ACC Kymore Cement Works 01/10/2012
234460-36 SCM 2 AG 21Oct08.ppt
Procurement Details

Vendor No. : 912000622 INFLATABLE GIANTS

Order No. : 1200352885

Cost : 3300 USD/Unit

Contact Person : Kyle Kutach


Senior OH&S Manager
Holcim (US) Inc.
1800 Dove Lane
Midlothian, Texas 76065
Office: (972) 923-5941
Cell: (214) 463-9376
Fax: (972) 923-5858
Email: kyle.kutach@holcim.com
www.holcim.us
6
ACC Kymore Cement Works 01/10/2012
234460-36 SCM 2 AG 21Oct08.ppt
7
ACC Kymore Cement Works 01/10/2012
234460-36 SCM 2 AG 21Oct08.ppt

Anda mungkin juga menyukai