Analysis

o Checked from U2000,Neighbor is defined but Sample not taking


o ANR Refreshed with Algorithm Log OFF/ON – no impact to HO attempts
o Basic parameter: Some HO Parameter A3 Offset,A3_Hysteresis,Time to Trigger – Set correctly
o Sync issues - None
o Cell Status : In WO State & radiating – no issues
o Any Blacklist HO Defined - None
o Any extra Layer added at the time of impact – None
o Configuration Team:Checked CIO, ANR, CGI – these seem to be set correctly and we’re not
seeing an obvious root cause here.
o Back Office Team:checked the HO specific config (TAC, PCI, INTER, INTRA, EXT). All
parameters are correctly defined for the same. There is no possibility of hardware fault.
o While checking Measurement Report,There seems Measurement results are missing
o While Checking WestBrom OMC App.26187 Count not all the object have the Ncell counters
applied.So IM1928439 raised by 22nd June & assigned to Concern Team & it’s Open.
o For Other OMC Work in Progress
HO Define but Sample not taking Site 18000A11

Here A11 cell having HO issue with nearby


1st Tier Sites with 1800Layer Only & L800
working fine.

18000A11 (27834) -> 99334B11 (27749) –


Handover relation defined but there are no
handovers between these cells - Stopped
since 21-07-2017

99334B11 (27749) -> 18000A11 (27834) –


Handover relation defined but there are no
handovers between these cells - Stopped
since 14-10-2017

95077C11 (14050) -> 18000A11 (27834) –


Handover relation defined but there are no
handovers between these cells. No
handovers since 24-06-2017
How To Find Measurement Report
• After Open U2000,go to Function
Search & Type Measure,Now Selecte
Measurement Management
How To Find Measurement Report
• After Open Measurement
Management Report,Select Setting
How To Find Measurement Report
• Now Type Site Id(ex-18000) & Select
Measurement Related to
Handover(LTE)
How To Find Measurement Report
• Function Subset Select LTE Cell to
LTE Cell & Check Measurement
Count & Below all are checked or
not.for Site 18000 we found some
discrepancy after Checked.HO
Starts taking sample.
2000
4000
6000
8000

0
10000
12000
5/22/2017
5/23/2017
5/24/2017
5/25/2017
5/26/2017
5/27/2017
5/28/2017
5/29/2017
5/30/2017
5/31/2017
6/1/2017
6/2/2017
6/3/2017
6/4/2017
6/5/2017
6/6/2017
6/7/2017
6/8/2017
6/9/2017
6/10/2017
6/11/2017
6/12/2017
6/13/2017
6/14/2017
6/15/2017
6/16/2017
6/17/2017
6/19/2017
6/20/2017
6/21/2017
6/22/2017
6/23/2017
6/24/2017
6/25/2017
18000A11 HO Report

6/26/2017
NCell Prepattout

6/27/2017
6/28/2017
6/29/2017
6/30/2017
7/1/2017
7/2/2017
7/3/2017
7/4/2017
7/5/2017
7/6/2017
7/7/2017
7/8/2017
7/9/2017
7/10/2017
7/11/2017
7/12/2017
7/13/2017
7/14/2017
7/15/2017
7/16/2017
7/17/2017
7/18/2017
7/19/2017
7/20/2017
7/21/2017
6/22/2018
6/23/2018
6/24/2018
June
• Here we Can See

& after Correction of


18000A11 not taking
any samples after 21st
July-17 with 99334B11

taking traffic since 22nd


Measurement,Cell start
After Enabled,HO Start taking Sample
• Function Subset Select LTE Cell to
Period Start Time (Truncated) Source TMUK ID Source Cell ID Target ENodeB ID Target Cell ID L Hho Ncell Prepattout
LTE Cell & Check Measurement
22/06/2018 00:00 18000 0 27749 1 178
Count & Below all are checked or
23/06/2018 00:00 18000 0 27749 1 474

24/06/2018 00:00 18000 0 27749 1 451


not.for Site 18000 we found some
discrepancy after Checked.HO
Starts taking sample.

Period Start Time (Truncated) Source TMUK ID Source Cell ID Target ENodeB ID Target Cell ID L Hho Ncell Prepattout

22/06/2018 00:00 99334 1 27834 0 197

23/06/2018 00:00 99334 1 27834 0 477

24/06/2018 00:00 99334 1 27834 0 459


WestBrom OMC App 26187 Count Ncell are
Missing
• Here N/W level on WestBrom
OMC Approximate 26187
Count not all the object have
the Ncell counters applied.
THANK YOU

Anda mungkin juga menyukai