ART-SEP/03 V02
PNMT 1
FUNCTIONS NECITR-YTC
ART-SEP/03 V02
PNMT 2
PNMT COMMUNICATION INTERFACE NECITR-YTC
ART-SEP/03 V02
COMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :
VIA THE LA PORT OF THE LOCAL PASOLINK EQUIPMENT
VIA THE DIGITAL SERVICE CHANNEL DSC TO A REMOTE PASOLINK EQUIPMENT
LA PORT
PNMT 3
HARDWARE/SOFTWARE CONFIGURATION NECITR-YTC
ART-SEP/03 V02
CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU LA PORT USING A RS232C CABLE PREPARATION
From the Control Panel select Phone
DOUBLE CLICK ON THE PNMT SHORTCUT and Modem Options. Add a Standard
ICON ON THE DESKTOP OR CLICK ON 19200 bps Modem and assign it to the
START>>PROGRAM>>PNMT>>PNMT COM1 port ( or the COM port to be
used)
Create a Dial-up connection using the
above standard modem and name it
as “pnmt”
PNMT 5
SHUT DOWN NECITR-YTC
ART-SEP/03 V02
PNMT 6
PNMT MAIN SCREEN NECITR-YTC
ART-SEP/03 V02
PNMT MAIN SCREEN IS SPLIT EVENLY TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.
PNMT WINDOW
MENU BAR
COMMON TOOL BAR
BLOCK DIAGRAM
NE-SPECIFIC DATA
PNMT 7
PNMT MAIN SCREEN NECITR-YTC
ART-SEP/03 V02
DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P
AND PMC) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.
NE BLOCK DIAGRAM:
STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND PMC) ARE SHOWN IN THE BLOCK
DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE
DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,
PNMT 8
PNMT WINDOW MENU ITEMS NECITR-YTC
ART-SEP/03 V02
CHANGE PASSWORD THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND
DEFINE THE BUZZER SOUND
ALARM BUZZER
CONNECT THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN
THE NETWORK
EXIT
PNMT 9
NE SPECIFIC MENU ITEMS NECITR-YTC
ART-SEP/03 V02
THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND
DISPLAY THE INFORMATION IN EVENT LOG WINDOW
FREQUENCY SETTING
TX POWER CONT
BIT RATE
EQUIPMENT SETUP SYSTEM CONFIG
MAINTENANCE LAN SETTING
FRAME ID
BER THRESHOLD
PNMT 10
PNMT LOGIN / LOGOUT & EXIT NECITR-YTC
ART-SEP/03 V02
CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN
THE LOGIN/LOGOUT WINDOW
PNMT 11
USER NAMES & PRIVILEGES NECITR-YTC
ART-SEP/03 V02
PNMT 12
OVERALL WINDOW NECITR-YTC
ART-SEP/03 V02
TX ATTENUATION USED
FRAME ID USED
CLICK THE OVERALL TAB TO DISPLAY THE OVERALL TX POWER CONTROL USED
WINDOW
PNMT 13
ODU WINDOW NECITR-YTC
ART-SEP/03 V02
CLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU
WINDOW TO VIEW THE ODU DETAILS
ODU WINDOW FOR (1+1) CONFIGURATION ODU WINDOW FOR (1+0) CONFIGURATION
CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS
PNMT 14
ODU DETAIL NECITR-YTC
ART-SEP/03 V02
ALARMS
IF INPUT – IF INPUT LEVEL IN THE ODU FALLS BELOW (APPROXIMATELY) -63 dB
TX APC – ODU TX SIDE SYNTHESIZER IS UNLOCKED
TX POWER – TRANSMIT POWER DECREASED BY 3 TO 5 dB
STATUS AND MONITORING
TX ATTENUATION – INDICATES THE ATTENUATION VALUE USED IN MTPC MODE
TX POWER – INDICATES THE ODU TRANSMIT POWER AS DETECTOR VOLTAGE AND IN dBm
ALARMS
ODU-IDU LINK – INDICATES THE STATUS OF THE COMMUNICATION BETWEEN IDU AND ODU
STATUS COLORS
GREEN NORMAL
RED ALARM
PNMT 15
IDU WINDOW NECITR-YTC
ART-SEP/03 V02
CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
IDU WINDOW FOR (1+0) CONFIGURATION IDU WINDOW FOR (1+1) CONFIGURATION
CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
PNMT 16
IDU DETAIL NECITR-YTC
ART-SEP/03 V02
PNMT 17
IDU DETAIL NECITR-YTC
ART-SEP/03 V02
STATUS COLORS
GREEN NORMAL
RED ALARM
YELLOW MAINTENANCE
BP OUTPUT – RX 2MB SIGNAL LOSS
DETECTED FROM DEMODULATOR
NORMAL/ALARM/INHIBIT
NORMAL/ALARM
NORMAL/SEND
NORMAL/RECEIVED
ON/OFF
2MB CH STATUS AND ALARMS ON/OFF
INPUT – LOSS OF 2MB INPUT SIGNAL ON/OFF
PNMT 19
CHANGE PASSWORD NECITR-YTC
ART-SEP/03 V02
PNMT 20
ALARM BUZZER NECITR-YTC
ART-SEP/03 V02
BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES
AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL
FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED
BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.
PNMT 21
SEARCH / CONNECT TO NETWORK ELEMENT NECITR-YTC
ART-SEP/03 V02
CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.
LIST MENU
PNMT 22
HELP FUNCTION NECITR-YTC
ART-SEP/03 V02
PNMT 23
EQUIPMENT CONFIGURATION WINDOW NECITR-YTC
ART-SEP/03 V02
INDICATES THE TX
POWER CONTROL MODE
AND TX ATT
SHOW THE TYPE AND NUMBER
SHOW THE CURRENT IDU OF OPTIONAL INTERFACE
CONFIGURATION CARDS MOUNTED
PNMT 24
FREQUENCY AND POWER SETTING NECITR-YTC
ART-SEP/03 V02
ODU SECTION OF THE EQUIPMENT SETUP WINDOW FOR THE SELECTED PASOLINK HAS THREE
CONTROLS, FREQUENCY PLAN , TX ATTENUATION AND TX POWER CONTROL SETTING.
IN THE CASE OF (1+1) HOT STANDBY CONFIGURATION, FREQUENCY IS SET FOR BOTH ODUs.
TX POWER CONTROL
SELECTS THE TX POWER CONTROL MODE WHEN TC CONTROL MODE IS ATPC, TX
ATPC OR MTPC. WHEN ATPC IS SELECTED, ATTENUATION SETTING VALUE IS IGNORED
“ATPC RX THRESHOLD” , ”ATPC MAX POWER”
AND “ATPC MIN POWER” BUTTONS ARE ACTIVE. WHEN TX CONTROL MODE IS CHANGED
FROM ATPC TO MTPC, THE TX ATTENUATION
SETTING IS AUTOMATICALLY SET TO THE
ATPC MAX POWER SETTING VALUE.
RX THRESHOLD LEVEL
WHEN THE MONITORED RX SIGNAL LEVEL
FALLS BELOW THIS LEVEL, CONTROL SIGNAL
SENT TO THE OPPOSITE STATION INITIATE THE
ATPC FUNCTION.
THIS IS EFFECTIVE ONLY WHEN THE OPPOSITE
STATION IS SET TO ATPC MODE
AUTOMATIC TX POWER MAX AND MIN RANGE CLICK THE APPROPRIATE BUTTON TO
OPEN THE SELECTED SETTING WINDOW..
ATPC RANGE DEFINES THE MAXIMUM AND MINIMUM TRANSMISSION POWER
DURING ATPC OPERATION. IN MTPC MODE THIS MENU ITEM DOES NOT APPEAR.
AFTER SELECTING OR SETTING THE
PARAMETER CLICK EXECUTE BUTTON TO
VALUE SET IS THE ATTENUATION IN dB FROM MAX ODU POWER. IMPLEMENT THE SETTING.
IF THE MAXIMUM OUTPUT POWER OF THE ODU IS +20 DBM, THEN FOR AN ATPC MAX
IN ALL SETTING WINDOWS, CLICK CLOSE
PWR SETTING OF 0DB AND ATPC MIN PWR SETTING OF -10DB, THE ODU OUTPUT
TO EXIT THE WINDOW
POWER DURING ATPC OPERATION CAN VARY BETWEEN +20 DBM AND +10 DBM
PNMT 26
IDU SETTING NECITR-YTC
ART-SEP/03 V02
REDUNDANCY
CLICK REDUNDANCY BUTTON TO OPEN THE REDUNDANCY BER THRESHOLD SETTING
CONFIGURATION SETTING WINDOW. SELECT THE REQUIRED CLICK BER THRESHOLD BUTTON TO OPEN THE BER
CONFIGURATION. CLICK ON THE EXECUTE BUTTON TO SET THE THRESHOLD SETTING WINDOW. SELECT THE DESIRED
REDUNDANCY CONFIGURATION. VALUE FOR THE BER THRESHOLD. CLICK ON THE
EXECUTE BUTTON TO SET THE BER THRESHOLD VALUE.
FRAME ID
CLICK FRAME ID BUTTON TO OPEN THE
FRAME ID SETTING WINDOW.
SELECT THE FRAME ID AND CLICK ON AT THIS BER THRESHOLD VALUE AIS SIGNAL IS INSERTED
THE EXECUTE BUTTON TO SET IT. TO THE 2MB STREAMS
MAKE SURE THAT BOTH NEs IN THE
HOP HAVE THE SAME FRAME ID VALUE.
PNMT 27
AIS SEND / RCVD SETTING NECITR-YTC
ART-SEP/03 V02
IN THE PASOLINK SYSTEM WHEN AIS IS DETECTED FROM THE INPUT 2MB STREAM AIS RCVD CONDITION IS DECLARED. THIS CONDITION
CAN BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT. SIMILARLY AIS IS SENT TO THE 2MB STREAM IN THE RECEIVE
DIRECTION UNDER CERTAIN CONDITIONS. AIS SEND CAN ALSO BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT.
PNMT 28
SERVICE CHANNEL SETTING NECITR-YTC
ART-SEP/03 V02
SC4
SC4
SELECT THE REQUIRED OPTION AND CLICK EXECUTE. CLICK CLOSE TO EXIT THE WINDOW
PNMT 29
NECITR-YTC
PMC CARD SETTING ART-SEP/03 V02
PNMT 30
MAINTENANCE NECITR-YTC
ART-SEP/03 V02
PNMT 31
AUX I/O WINDOW - MONITORING NECITR-YTC
ART-SEP/03 V02
AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE
PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS
ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS.
CLICK THE AUX SYMBOL IN THE BLOCK DIAGRAM OR AUX I/O TAB TO
VIEW THE AUX ALARM/STATUS/CONTROL DISPLAY CONFIGURE CONTROL RELAY OUTPUTS
CLICK THE OUTPUT 1-4 BUTTONS TO CONFIGURE
THE EXTERNAL CONTROLS
ENTER THE NAME TO
APPEAR FOR
SELECTED CONTROL
ITEM ( UP TO 32
CHARACTERS)
PNMT 32
PMC & VERSION WINDOWS NECITR-YTC
ART-SEP/03 V02
CLICK THE PMC SYMBOL ON THE BLOCK DIAGRAM OR CLICK THE VERSION TAB TO DISPLAY THE VERSION
THE PMC TAB TO DISPLAY THE PMC WINDOW FOR THE INFORMATION WINDOW FOR THE SELECTED NE.
SELECTED NE.
PNMT 33
DATE TIME SETTING NECITR-YTC
ART-SEP/03 V02
DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENT’S PM CARD CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM
[PMC WINDOW]
TO DISPLAY THE CURRENT DATE/TIME
STORED IN THE PM CARD, SELECT
GET DATE/TIME AND CLICK EXECUTE.
CLICK DATE/TIME
BUTTON IN THE PMC
WINDOW TO OPEN THE THE CURRENT DATE/TIME STORED IN
DATE/TIME SETTING THE PM CARD, IS DISPLAYED.
CONTROL WINDOW
TO CHANGE THE PM CARD DATE TIME SETTING, TO CHANGE THE PM CARD DATE TIME SETTING,
SELECT SET DATE/TIME. SELECT SET DATE/TIME.
PNMT 34
DOWN LOAD CONFIGURATION FILES NECITR-YTC
ART-SEP/03 V02
UPDATE
A MESSAGE WINDOW INDICATE THE STATUS OF
AFTER THE SUCCESSFUL DOWN LOAD OF
THE DOWNLOAD OPERATION AND IT WILL CLOSE
THE CONFIGURATION FILES. CLICK
AUTOMATICALLY ONCE THE OPERATION IS OVER
UPDATE BUTTON. UPDATE
CONFIGURATION FILE WINDOW OPENS. System Config
WARNING
SELECT THE APPROPRIATE BOX FOR THE Network Config
MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWN
TYPE OF CONFIGURATION FILE(S) THAT ME Config LOADED TO THE PM CARD IN THE CORRECT NE. INCORRECT
WILL BE UPDATED. CONFIGURATION FILE WILL LEAD TO PM CARD OR NETWORK
PPP Config
CLICK OK BUTTON TO START THE UPDATE FAILURE
OPERATION..
MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED
With ROM (PMC Program ) Switching
WHEN UPDATING SYSTEM.CFG FILE , PMC TO THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE
PMC COMMUNICATION WILL BE LOST WHEN PM THE PM CARD WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE
CARD INITIALIZES TO THE NEW SYSTEM Execute PM CARD FAILURE.
CONFIGURATION. DURING THIS TIME PNMT
CONNECTION TO THE PASOLINK WILL BE LOST
BUT WILL AUTOMATICALLY BE RECONNECTED CLICK CLOSE BUTTON WHEN DONE
AFTER THE PMC RESETS
PNMT 35
DOWN LOAD PROGRAM FILE NECITR-YTC
ART-SEP/03 V02
CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>PMC) IN THE
PMC WINDOW.
[PMC WINDOW]
ENTER THE PATH TO THE
A:\pm.pof PROGRAM FILE TO BE
DOWNLOADED OR CLICK BROWSE
PM CARD CAN BE RESET TO LOCATE THE PROGRAM FILE.
USING THIS FUNCTION
PNMT 36
UPLOAD CONFIGURATION FILE NECITR-YTC
ART-SEP/03 V02
[PMC WINDOW] CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (PM>>PC) TO OPEN
THE UPLOAD CONFIGURATION FILE WINDOW.
ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN
THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF
NECESSARY.
PNMT 37
EVENT LOG NECITR-YTC
ART-SEP/03 V02
A MESSAGE WINDOW
SHOWS THE PROGRESS OF
THE UPLOAD
PNMT 38
LINK PERFORMANCE MONITOR NECITR-YTC
ART-SEP/03 V02
PNMT 39
LINK PERFORMANCE MONITOR NECITR-YTC
ART-SEP/03 V02
PNMT 40
NECITR-YTC
ART-SEP/03 V02
PASOLINK V4 SOFTWARE
PNMT 41