Anda di halaman 1dari 41

PNMT - GENERAL NECITR-YTC

ART-SEP/03 V02

PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A


PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK
MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORT
HAUL RADIO TRANSMISSION NETWORK.

PNMT IS DESIGNED AS AN ONSITE MAINTENANCE


TOOL TO BE USED BY THE FIELD ENGINEERS AND
TECHNICIANS. IT CONNECTS DIRECTLY TO THE LA
PORT OF THE PASOLINK IDU. PNMT CAN BE USED
TO MONITOR LOCAL / REMOTE EQUIPMENT
STATUS AND PROVIDES CONTROL CAPABILITIES
SIMILAR TO THOSE AVAILABLE IN PNMS.
PNMT IS ALSO USED TO DOWN LOAD THE SYSTEM
AND CONFIGURATION FILES TO THE PM CARD AND
UPGRADE THE SOFTWARE IN THE IDU

WHEN CONNECTED TO AN IDU PNMT CAN


MONITOR NOT ONLY THE LOCAL EQUIPMENT BUT
ANY REMOTE NETWORK ELEMENT UNDER THE
CONTROL OF THE CENTRAL PM CARD.
TO USE THE PNMT, PM CARD SHOULD BE
MOUNTED IN THE IDUs.

PNMT 1
FUNCTIONS NECITR-YTC
ART-SEP/03 V02

MICROSOFT WINDOWS 98/NT/200/XP WORKSTATION GRAPHICAL USER INTERFACE


ONE HOP LINK DISPLAY ON THE PNMT SCREEN
COMMUNICATE WITH REMOTE PM CARDS ON THE SAME NETWORK
COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE PM CARDS
TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE PM CARDS
SEVERAL LEVELS OF LOGIN / LOGOUT
EVENT LOGGING WINDOW
PERFORMANCE MONITORING FUNCTION WINDOW
LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION
LOCAL/REMOTE PM CARD CONFIGURATION MANAGEMENT
LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE

PNMT 2
PNMT COMMUNICATION INTERFACE NECITR-YTC
ART-SEP/03 V02

COMMUNICATION BETWEEN THE PNMT AND THE RADIO NETWORK EQUIPMENT CAN BE :
VIA THE LA PORT OF THE LOCAL PASOLINK EQUIPMENT
VIA THE DIGITAL SERVICE CHANNEL DSC TO A REMOTE PASOLINK EQUIPMENT

LA PORT IS LOCATED ON THE FRONT OF THE EQUIPMENT AND


CONSISTS OF A DB15 CONNECTOR. LA PORT CONNECT THE
PM CARD IN THE IDU VIA A SERIAL CABLE TO THE RELEVANT
COMMUNICATION PORT OF THE PNMT COMPUTER.
PROPERTIES OF THE LA PORT ARE AS FOLLOWS:
PORT CONFIGURATION RS-232
CONNECTOR TYPE D-SUB 15 (FEMALE)
BITS PER SECOND RATEUP TO 19200

LA PORT

PNMT 3
HARDWARE/SOFTWARE CONFIGURATION NECITR-YTC
ART-SEP/03 V02

RECOMMENDED PNMT MOBILE PC CONFIGURATION


LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE)
CPU: PENTIUM-400 OR HIGHER
RAM: 128 MB OR MORE
HDD: 2 GB OR MORE
FDD: 3.5INCH
CD-ROM: 8 x OR HIGHER
INTEGRATED SOUND CARD AND SPEAKER
SOFTWARE CONFIGURATION
ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD-DISK
AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED
WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS
OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM
OPERATING SYSTEM
WINDOWS 98 (ENGLISH VERSION)
WINDOWS NT WORKSTATION Ver 4.0 (ENGLISH VERSION) WITH SP 6.0 OR HIGHER
WINDOWS 2000 (ENGLISH VERSION) WITH SP3 OR HIGHER
WINDOWS XP (ENGLISH VERSION) WITH SP1 OR HIGHER
APPLICATION PROGRAM
NEC PNMT SOFTWARE
IE 5.0 OR HIGHER
ACROBAT READER
PNMT 4
START UP NECITR-YTC
ART-SEP/03 V02

CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU LA PORT USING A RS232C CABLE PREPARATION
From the Control Panel select Phone
DOUBLE CLICK ON THE PNMT SHORTCUT and Modem Options. Add a Standard
ICON ON THE DESKTOP OR CLICK ON 19200 bps Modem and assign it to the
START>>PROGRAM>>PNMT>>PNMT COM1 port ( or the COM port to be
used)
Create a Dial-up connection using the
above standard modem and name it
as “pnmt”

Install the NEC PNMT software

See PNMT Install Manual for details

PNMT PROGRAM STARTUP AND


TRIES TO GET CONNECTED TO
PASOLINK EQUIPMENT USING THE
DIAL-UP CONNECTION “PNMT”

AFTER CONNECTING TO THE PASOLINK


EQUIPMENT TRIES TO ACQUIRE DATA FROM
THE LOCAL EQUIPMENT AND THE REMOTE
EQUIPMENT TO DISPLAY ON THE LINK
SUMMARY WINDOW

PNMT 5
SHUT DOWN NECITR-YTC
ART-SEP/03 V02

IF YOU HAVE NOT LOGIN FIRST THE


EXIT MENU CANNOT BE SELECTED.

TO EXIT THE PNMT PROGRAM


CLICK ON EXIT IN THE SYSTEM
DROPDOWN MENU AND CLICK YES.

IN THE DIALOG BOX


THAT OPENS CLICK
YES

THE SCREEN INDICATES NOW PNMT


SHUTDOWN. IT WILL TAKE FEW MINUTES TO
SHUTDOWN

PNMT 6
PNMT MAIN SCREEN NECITR-YTC
ART-SEP/03 V02

PNMT MAIN SCREEN IS SPLIT EVENLY TO DISPLAY THE DATA FROM THE TWO NEs IN THE HOP.

PNMT WINDOW
MENU BAR
COMMON TOOL BAR

LINK SUMMARY WINDOW

NE-SPECIFIC MENU ITEMS

BLOCK DIAGRAM

NE-SPECIFIC DATA

CLICK ON THE ARROW


ICONS IN THE MIDDLE OF
THE SCREEN TO EXPAND
THE LEFT OR RIGHT DATA
FIELD. CLICKING ON THE
BLOCK WILL RETURN THE
ORIGINAL SPLIT SCREEN.

TAB SELECTION FOR


OTHER EQUIPMENT
VIEWS

PNMT 7
PNMT MAIN SCREEN NECITR-YTC
ART-SEP/03 V02

COMMON MENU BAR


COMMON MENU BAR OF THE PNMT WINDOW PRESENTS THE SYSTEM AND HELP MENU ITEMS. EACH MENU ITEM
HAVE A DROP DOWN MENU SHOWING THE OPTIONS AVAILABLE.

COMMON TOOL BAR


COMMON TOOL BAR OF THE PNMT WINDOW HOLDS THE ICONS OF THE FREQUENTLY USED MENU ITEMS

LINK SUMMARY WINDOW


LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP).
THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE
WINDOW OF THE LINK SUMMARY WINDOW. IT SHOWS GRAPHICALLY THE STATUS OF THE PASOLINK EQUIPMENT IN
BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS
WINDOW
NE SPECIFIC DATA :
NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE
WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM. DATA DISPLAYED DEPENDS
ON THE EQUIPMENT TYPE (PASOLINK +, V3, V4, ETC.)
NE SPECIFIC MENU ITEMS:

EQUIPMENT CONFIGURATION EQUIPMENT SETUP


MAINTENANCE
LINK PERFORMANCE MONITOR
EVENT LOG
TAB SELECTION

DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P
AND PMC) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB.

NE BLOCK DIAGRAM:

STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND PMC) ARE SHOWN IN THE BLOCK
DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE
DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,

PNMT 8
PNMT WINDOW MENU ITEMS NECITR-YTC
ART-SEP/03 V02

SYSTEM REFRESH HELP

HELP DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT

ABOUT DISPLAY THE PNMT VERSION NUMBER

THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY


AND TO UPDATE EQUIPMENT INFORMATION

THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE


USER NAME AND PASSWORD.

THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW


LOGIN / LOGOUT

CHANGE PASSWORD THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND
DEFINE THE BUZZER SOUND
ALARM BUZZER

CONNECT THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN
THE NETWORK
EXIT

THIS FUNCTION IS USED TO CLOSE THE PNMT PROGRAM

PNMT 9
NE SPECIFIC MENU ITEMS NECITR-YTC
ART-SEP/03 V02

CONFIGURATION EVENT LOG LINK PERFORMANCE MONITOR

THIS FUNCTION OPEN THE G826 LINK PERFORMANCE INFORMATION WINDOW.

THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND
DISPLAY THE INFORMATION IN EVENT LOG WINDOW

FREQUENCY SETTING

TX POWER CONT

BIT RATE
EQUIPMENT SETUP SYSTEM CONFIG
MAINTENANCE LAN SETTING

FRAME ID

BER THRESHOLD

AIS SEND ON/OFF


MAINT MODE ON/OFF
AIS RCVD ON/OFF
TX MUTE ON/OFF
SC4 & SC5 SETTING
CW ON/OFF
NE NAME
BER AIS ON/OFF
NOTE
SWITCHOVER (1+1)

PNMT 10
PNMT LOGIN / LOGOUT & EXIT NECITR-YTC
ART-SEP/03 V02

CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN
THE LOGIN/LOGOUT WINDOW

TO LOGIN SELECT LOGIN IN THE


LOGIN/LOGOUT WINDOW.

ENTER THE USER NAME ACCORDING TO THE


PRIVILEGES AND THE PASSWORD.
CLICK OK TO LOGIN
TO PROTECT THE NETWORK AND NETWORK
MANAGEMENT SYSTEM FROM UNAUTHORIZED
ACCESS OR MODIFICATIONS, FIVE LEVELS OF
USERS ARE DEFINED WITH DIFFERENT
PRIVILEGES. THE FUNCTIONS AVAILABLE
DEPENDS ON THE USER ACCESS LEVEL, (SEE
THE TABLE NEXT PAGE)

TO LOGOUT SELECT LOGOUT IN THE


LOGIN/LOGOUT WINDOW AND CLICK OK.

PNMT 11
USER NAMES & PRIVILEGES NECITR-YTC
ART-SEP/03 V02

Category Item Monitor(0) User(1) Local(2) Remote(3) Admin(4)


MENU-SYSTEM DATE TIME   
ALARM BUZZER    
DOWNLOAD PMC PROGRAM FILE 
CONNECT (REMOTE LOGIN)  
MENU-CONFIGURATION FILE DOWNLOAD FILE/ UPLOAD FILE 
UPDATE 
IDU WS ALARM INHIBIT (OPTION)    
CH (LB1) / CH(LB2)   
CH (ALARM INHIBIT)    
MAINTENANCE MAINTENANCE MODE    
TX MUTE   
CW   
BER AIS    
SWITCH OVER (1+1)   
EQUIPMENT CONFIGURATION FREQUENCY PLAN (CH)   
TX ATTENUATION   
BIT RATE 
FRAME ID   
BER THRESHOLD    
AIS RCVD ALARM ON/OFF    
AIS SEND ALARM ON/OFF    
SC4 AND SC5    
PASOLINK NAME   
NOTE    
AUX I/O OPTO ITEM TYPE    
OPTO NAME    
RELAY NAME    
RELAY CONTROL    
PMON PMON THRESHOLD    
PMON DATA RESET   
SAVE TO DISK    
LOGGING SAVE TO DISK    
PMC RESET   

PNMT 12
OVERALL WINDOW NECITR-YTC
ART-SEP/03 V02

OVERALL WINDOW FOR (1+1) CONFIGURATION

OVERALL WINDOW FOR (1+0) CONFIGURATION

OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION:

TX ATTENUATION USED

TX AND RX FREQUENCIES USED

BIT RATE USED

MAINTENANCE MODE ON OR OFF STATUS. IF ON, BACK GROUND COLOR


CHANGE TO YELLOW.

SELECTED TX AND RX CHANNEL IN (1+1) HOT STANDBY CONFIGURATION

FRAME ID USED

ODU TYPE USED V3 OR V4

CLICK THE OVERALL TAB TO DISPLAY THE OVERALL TX POWER CONTROL USED
WINDOW

PNMT 13
ODU WINDOW NECITR-YTC
ART-SEP/03 V02

CLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU
WINDOW TO VIEW THE ODU DETAILS

ODU WINDOW FOR (1+1) CONFIGURATION ODU WINDOW FOR (1+0) CONFIGURATION

CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS

PNMT 14
ODU DETAIL NECITR-YTC
ART-SEP/03 V02

TX SIDE ALARMS AND STATUS /MONITORING

ALARMS
IF INPUT – IF INPUT LEVEL IN THE ODU FALLS BELOW (APPROXIMATELY) -63 dB
TX APC – ODU TX SIDE SYNTHESIZER IS UNLOCKED
TX POWER – TRANSMIT POWER DECREASED BY 3 TO 5 dB
STATUS AND MONITORING
TX ATTENUATION – INDICATES THE ATTENUATION VALUE USED IN MTPC MODE
TX POWER – INDICATES THE ODU TRANSMIT POWER AS DETECTOR VOLTAGE AND IN dBm

(1+1) CONFIGURATION SELECTED/NOT SELECTED STATUS


GREEN SELECTED
WHITE NOT SELECTED

RX SIDE ALARMS AND STATUS /MONITORING


ALARMS
RX LEVEL – ODU RECEIVE LEVEL FALLS BELOW SQUELCH LEVEL
RX APC – ODU RX SIDE SYNTHESIZER IS UNLOCKED

STATUS AND MONITORING


RX LEVEL – INDICATES THE ODU RX LEVEL AS THE AGC VOLTAGE AND IN dBm

COMMON ALARMS AND STATUS /MONITORING

ALARMS
ODU-IDU LINK – INDICATES THE STATUS OF THE COMMUNICATION BETWEEN IDU AND ODU

STATUS AND MONITORING

ODU TYPE – INDICATES THE TYPE OF ODU CONNECTED TO THE V4 PASOLINK

STATUS COLORS
GREEN NORMAL
RED ALARM

PNMT 15
IDU WINDOW NECITR-YTC
ART-SEP/03 V02

CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS

IDU WINDOW FOR (1+0) CONFIGURATION IDU WINDOW FOR (1+1) CONFIGURATION

CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS

PNMT 16
IDU DETAIL NECITR-YTC
ART-SEP/03 V02

TX SIDE IDU ALARMS


MOD – MODULATOR 850 MHz PLL OSCILLATOR UNLOCK ALARM
TX DPU – LOSS OF TX SIDE CLOCK

(1+1) CONFIGURATION ON LINE SELECTED/NOT SELECTED STATUS


STATUS COLORS GREEN SELECTED
GREEN NORMAL WHITE NOT SELECTED
RED ALARM
PINK MINOR ALARM
RX SIDE IDU ALARMS

DEM – RX CARRIER NOT SYNCHRONIZED OR LOST


LOW BER – WHEN THE RECEIVE BER IS > 10-6
HIGH BER – WHEN THE RECEIVE BER IS >10-3
BER ALARM – ALARM TRIGGER POINT SELECTABLE (10-3,10-4,10-5 AND 10-6)
FRAME ASYNC – LOSS OF RX FRAME SYNCHRONIZATION AT THE RX DPU
RX CLK LOSS – LOSS OF RX SIDE CLOCK

IDU COMMON ALARMS

ODU-IDU LINK – STATUS OF THE ODU-IDU IF LINK


CPU – STATUS OF THE IDU CPU

WAY SIDE( OPTION) ALARMS


INPUT – LOSS OF WS INPUT SIGNAL IN THE WS INTFC CARD
BP OUTPUT – RX WS SIGNAL LOSS FROM DEMODULATOR (WS INTFC CARD)
AIS SEND – STATUS AIS SENT OUT FORM THE WS INTFC CARD
AIS RECEIVED – AIS DETECTED IN WS INPUT SIGNAL
ALARM INHIBIT – WHEN WS SIGNAL IS NOT USED ALARM INHIBIT STATUS
Normal
LAN INTFC (OPTION) ALARMS
Port 1 Port 2
Normal Normal LAN INTFC – LAN INTERFACE OPTION CARD IS NORMAL OR FAULTY
Normal Normal LAN LINK – LAN PORT 1 & 2 LINK STATUS NORMAL OR ALARM
LAN COLLISION – COLLISION STATUS OF THE LAN PORT 1 & 2

PNMT 17
IDU DETAIL NECITR-YTC
ART-SEP/03 V02

CLICK THE CH BUTTON TO OPEN THE CHANNEL


CONTROL WINDOW
LOOPBACK 1 CONTROL
LOOPBACK 2 CONTROL
CH ALARM INHIBIT CONTROL

STATUS COLORS
GREEN NORMAL
RED ALARM
YELLOW MAINTENANCE
BP OUTPUT – RX 2MB SIGNAL LOSS
DETECTED FROM DEMODULATOR
NORMAL/ALARM/INHIBIT
NORMAL/ALARM
NORMAL/SEND
NORMAL/RECEIVED
ON/OFF
2MB CH STATUS AND ALARMS ON/OFF
INPUT – LOSS OF 2MB INPUT SIGNAL ON/OFF

BP OUTPUT – RX 2MB SIGNAL LOSS DETECTED FROM DEMODULATOR


AIS SEND – AIS SENT OUT STATUS FORM THE 2MB INTFC CARD ALARM INHIBIT
WS OFF
AIS RECEIVED – AIS DETECTED STATUS IN 2MB INPUT SIGNAL
LB-1– UNDER MAINTENANCE MODE NEAR END LOOPBACK STATUS
LB-2 – UNDER MAINTENANCE MODE, TO FAR END LOOPBACK STATUS
ALARM INHIBIT – ALARM INHIBIT STATUS OF NOT USED 2MB STREAMS

WS CH STATUS AND ALARMS


INPUT – LOSS OF 2MB WS INPUT SIGNAL
BP OUTPUT – RX 2MB WS SIGNAL LOSS DETECTED FROM DEMODULATOR
AIS SEND – AIS SENT OUT STATUS FORM THE WS INTFC CARD
AIS RECEIVED – AIS DETECTED STATUS IN WS INPUT SIGNAL
ALARM INHIBIT – ALARM INHIBIT STATUS OF NOT USED 2MB STREAMS
PNMT 18
CHANNEL CONTROL NECITR-YTC
ART-SEP/03 V02

INDICATE LOOPBACK ON, YELLOW BACKGROUND


IN THE IDU WINDOW CLICK ON
INDICATE MAINTENANCE MODE
THE CH # TO BE CONTROLLED.
SELECTED CHANNEL CONTROL
WINDOW OPENS
INDICATE CHANNEL ALARMS INHIBIT ON

INDICATE CHANNEL ALARMS INHIBIT ON

LB1 TAB PROVIDES NEAR END LOOPBACK.


SELECT ON OR OFF AND CLICK ON
EXECUTE TO ENABLE NEAR END
LOOPBACK ON THE SELECTED CHANNEL.
BEFORE ENABLING LOOPBACK SELECT ALARM TAB PROVIDES INHIBIT OF ALARM
MAINTENANCE MODE ON. OTHERWISE AN ON THE SELECTED CHANNEL. USED TO
ERROR MESSAGE. IS DISPLAYED LB2 TAB PROVIDES FAR END INHIBIT ALARMS FROM THE UNUSED 2 MB
LOOPBACK. SELECT ON OR OFF AND CHANNELS.
CLICK ON EXECUTE TO ENABLE FAR ON – INHIBIT ALARMS
END LOOPBACK ON THE SELECTED
CHANNEL.. OFF - ENABLE ALARMS
CLICK EXECUTE TO SELECT THE CHANGE

PNMT 19
CHANGE PASSWORD NECITR-YTC
ART-SEP/03 V02

CLICK ON CHANGE PASSWORD IN THE SYSTEM


DROPDOWN MENU TO OPEN THE CHANGE PASS WORD
WINDOW.

ENTER THE OLD PASSWORD

ENTER THE NEW PASSWORD

RE-ENTER THE NEW PASSWORD TO CONFIRM

CLICK OK TO CHANGE THE


PASSWORD.

CLICK CANCEL TO EXIT WITHOUT


CHANGING PASSWORD

PNMT 20
ALARM BUZZER NECITR-YTC
ART-SEP/03 V02

CLICK ON ALARM BUZZER ON


THE SYSTEM DROP DOWN SELECT NO SOUND TO DISABLE THE BUZZER
MENU TO OPEN THE ALARM
BUZZER SETTING WINDOW.

SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER


SOUND CAN BE CHANGED BY SELECTING A DIFFERENT
WAV FILE. USE BROWSE TO LOCATE THE PATH TO
THE WAV FILE.

CLICK HERE TO TEST THE BUZZER SOUND

CLICK OK TO IMPLEMENT THE


OPTION SELECTED OR CLICK
CANCEL TO EXIT WITHOUT
CHANGING THE SETTINGS.

SELECT BEEP TO ENABLE THE


BUZZER WITH BEEP FREQUENCIES
INSTEAD OF WAVE FILE SOUND

BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES
AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL
FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED
BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.

PNMT 21
SEARCH / CONNECT TO NETWORK ELEMENT NECITR-YTC
ART-SEP/03 V02

CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.

LIST MENU

CLICK THE SEARCH FOR NETWORK ELEMENT TO


SEARCH AND LIST THE OTHER NEs IN THE
NETWORK

TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT AND


HIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK
ELEMENT FROM THE LIST DROP DOWN MENU. SELECT YES FROM THE
DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE
DISPLAYED IN THE LINK SUMMARY WINDOW.

TOOL BAR ITEMS

CONNECT TO NETWORK ELEMENT

SEARCH FOR NETWORK ELEMENT

PNMT 22
HELP FUNCTION NECITR-YTC
ART-SEP/03 V02

PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN


PDF FILE FORMAT. IF THE ACROBAT READER IS
INSTALLED IN THE PNMT PC, CLICKING HELP AND
SELECTING THE RELEVANT PNMT FILE WILL OPEN THE
PDF FILE TO PROVIDE HELP FUNCTION TO THE USER.

BUZZER STOP – ICON IS ACTIVE ONLY WHEN


THE, THE ALARMED EQUIPMENT DISPLAY
WINDOW IS SELECTED FROM THE TABs OR DISPLAY THE PNMT SOFTWARE VERSION INFORMATION
FROM THE BLOCK DIAGRAM SYMBOLS.

REFRESH – REFRESH METERING ITEMS

CONNECT - OPEN THE NE LIST WINDOW

OPEN THE LOGIN/LOGOUT WINDOW

PNMT 23
EQUIPMENT CONFIGURATION WINDOW NECITR-YTC
ART-SEP/03 V02

INDICATES THE ODU


FREQUENCY BAND
INFORMATION AND TX/RX
FREQUENCIES

INDICATES THE TX
POWER CONTROL MODE
AND TX ATT
SHOW THE TYPE AND NUMBER
SHOW THE CURRENT IDU OF OPTIONAL INTERFACE
CONFIGURATION CARDS MOUNTED

SHOW THE LAN SIGNAL


SHOW THE WS
STATUS FOR PORT1 AND
CHANNEL
PORT2, WHEN MAIN LAN
INFORMATION
INTFC OPTION IS USED
SHOW THE
SERVICE CHANNEL
INFORMATION
SHOW IP ADDRESS AND NAME OF
THE SELECTED NE

PNMT 24
FREQUENCY AND POWER SETTING NECITR-YTC
ART-SEP/03 V02

ODU SECTION OF THE EQUIPMENT SETUP WINDOW FOR THE SELECTED PASOLINK HAS THREE
CONTROLS, FREQUENCY PLAN , TX ATTENUATION AND TX POWER CONTROL SETTING.
IN THE CASE OF (1+1) HOT STANDBY CONFIGURATION, FREQUENCY IS SET FOR BOTH ODUs.

CLICK ON THE FREQUENCY PLAN BUTTON TO SELECT


THE ODU TX AND RX FREQUENCIES.

INFORMATION ABOUT THE ODU FREQUENCY BAND ARE


DISPLAYED

This information may include :

TX frequency used is High band or Low band


 Frequency Sub band used A, B, C, or D.
 Default Channel and TX frequency set in the ODU.
 CH Separation
 shift frequency
CLICK ON THE TX ATTENUATION
BUTTON TO SET THE TX ATTENUATION REFER TO THE RADIO FREQUENCY ASSIGNMENT TABLES TO
FOR MTPC. SELECT THE CHANNEL NUMBER CORRESPONDING TO THE
REQUIRED TRANSMIT AND RECEIVE FREQUENCIES.
SELECT THE CHANNEL NUMBER AND THE CORRESPONDING TX
AND RX FREQUENCIES FOR THE SELECTED CHANNEL. ARE
DISPLAYED

CLICK THE EXECUTE BUTTON TO CHANGE THE FREQUENCIES.


THIS OPERATION WILL INTERRUPT THE TRAFFIC

CLICK THE CLOSE BUTTON TO EXIT THE FREQUENCY PLAN


WINDOW.
SELECT THE AMOUNT OF ATTENUATION
REQUIRED AND CLICK THE EXECUTE BUTTON.
THE TX ATTENUATION RANGE OF ODU IS 0 TO
30 dB
CLICK CLOSE TO EXIT THE TX ATTENUATION
SETTING WINDOW.
PNMT 25
ATPC SETTING NECITR-YTC
ART-SEP/03 V02

TX POWER CONTROL
SELECTS THE TX POWER CONTROL MODE WHEN TC CONTROL MODE IS ATPC, TX
ATPC OR MTPC. WHEN ATPC IS SELECTED, ATTENUATION SETTING VALUE IS IGNORED
“ATPC RX THRESHOLD” , ”ATPC MAX POWER”
AND “ATPC MIN POWER” BUTTONS ARE ACTIVE. WHEN TX CONTROL MODE IS CHANGED
FROM ATPC TO MTPC, THE TX ATTENUATION
SETTING IS AUTOMATICALLY SET TO THE
ATPC MAX POWER SETTING VALUE.

RX THRESHOLD LEVEL
WHEN THE MONITORED RX SIGNAL LEVEL
FALLS BELOW THIS LEVEL, CONTROL SIGNAL
SENT TO THE OPPOSITE STATION INITIATE THE
ATPC FUNCTION.
THIS IS EFFECTIVE ONLY WHEN THE OPPOSITE
STATION IS SET TO ATPC MODE

AUTOMATIC TX POWER MAX AND MIN RANGE CLICK THE APPROPRIATE BUTTON TO
OPEN THE SELECTED SETTING WINDOW..
ATPC RANGE DEFINES THE MAXIMUM AND MINIMUM TRANSMISSION POWER
DURING ATPC OPERATION. IN MTPC MODE THIS MENU ITEM DOES NOT APPEAR.
AFTER SELECTING OR SETTING THE
PARAMETER CLICK EXECUTE BUTTON TO
VALUE SET IS THE ATTENUATION IN dB FROM MAX ODU POWER. IMPLEMENT THE SETTING.
IF THE MAXIMUM OUTPUT POWER OF THE ODU IS +20 DBM, THEN FOR AN ATPC MAX
IN ALL SETTING WINDOWS, CLICK CLOSE
PWR SETTING OF 0DB AND ATPC MIN PWR SETTING OF -10DB, THE ODU OUTPUT
TO EXIT THE WINDOW
POWER DURING ATPC OPERATION CAN VARY BETWEEN +20 DBM AND +10 DBM

PNMT 26
IDU SETTING NECITR-YTC
ART-SEP/03 V02

BIT RATE SETTING


IDU SECTION OF THE EQUIPMENT SETUP WINDOW FOR
CLICK BIT RATE BUTTON TO OPEN THE BIT RATE SETTING
THE SELECTED PASOLINK HAS CONTROL SETTINGS FOR
WINDOW. THIS FUNCTION APPLIES TO THE VARIABLE BIT RATE
THE MAIN SIGNAL.
IDUs. SELECT THE BIT RATE AND CLICK THE EXECUTE BUTTON
TO CHANGE THE BIT RATE SETTING..

REDUNDANCY
CLICK REDUNDANCY BUTTON TO OPEN THE REDUNDANCY BER THRESHOLD SETTING
CONFIGURATION SETTING WINDOW. SELECT THE REQUIRED CLICK BER THRESHOLD BUTTON TO OPEN THE BER
CONFIGURATION. CLICK ON THE EXECUTE BUTTON TO SET THE THRESHOLD SETTING WINDOW. SELECT THE DESIRED
REDUNDANCY CONFIGURATION. VALUE FOR THE BER THRESHOLD. CLICK ON THE
EXECUTE BUTTON TO SET THE BER THRESHOLD VALUE.

FRAME ID
CLICK FRAME ID BUTTON TO OPEN THE
FRAME ID SETTING WINDOW.
SELECT THE FRAME ID AND CLICK ON AT THIS BER THRESHOLD VALUE AIS SIGNAL IS INSERTED
THE EXECUTE BUTTON TO SET IT. TO THE 2MB STREAMS
MAKE SURE THAT BOTH NEs IN THE
HOP HAVE THE SAME FRAME ID VALUE.

PNMT 27
AIS SEND / RCVD SETTING NECITR-YTC
ART-SEP/03 V02

IN THE PASOLINK SYSTEM WHEN AIS IS DETECTED FROM THE INPUT 2MB STREAM AIS RCVD CONDITION IS DECLARED. THIS CONDITION
CAN BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT. SIMILARLY AIS IS SENT TO THE 2MB STREAM IN THE RECEIVE
DIRECTION UNDER CERTAIN CONDITIONS. AIS SEND CAN ALSO BE DEFINED AS AN ALARM CONDITION OR STATUS CHANGE EVENT.

CLICK AIS RCVD BUTTON TO OPEN THE


CLICK AIS SEND BUTTON TO OPEN THE
AIS RCVD SETTING WINDOW.
AIS SEND SETTING WINDOW.

SELECT AIS SEND CONDITION AS AN SELECT AIS RECEIVED CONDITION AS AN


ALARM CONDITION OR STATUS ALARM CONDITION OR STATUS
CONDITION. CONDITION.
CLICK EXECUTE TO CARRY OUT THE CLICK EXECUTE TO CARRY OUT THE
SETTING. SETTING.

CLICK CLOSE TO EXIT CLICK CLOSE TO EXIT

PNMT 28
SERVICE CHANNEL SETTING NECITR-YTC
ART-SEP/03 V02

OPTION PANEL STATUS SHOWS THE OPTION CARDS


MOUNTED IN THE IDU.

OVERHEAD SERVICE CHANNELS

SERVICE CHANNELS USED IN THE PASOLINK IS SHOWN ON SC1 EOW Analog


THE TABLE. SC2 AND 3 NEEDS OPTIONAL ANALOG OR
DIGITAL SERVICE CHANNEL INTERFACE CARD. SC2 DSC3 Analog ASC INTFC or Option
SC3 DSC4 Digital DSC INTFC Option
SC4 AS A DEFAULT USE A 9.6K RS232 INTERFACE. IF THE
OPTIONAL 64K INTERFACE CARDS ARE MOUNTED. THEN THE SC4 DSC1 Digital 9.6Kbps RS 232C or
SC4 BUTTON IS ACTIVE TO SELECT EITHER 9.6 OR 64K. 64Kbps with G703/V11 card Option
INTERFACE SC5 DSC2 Digital 9.6Kbps RS232C / RS422 / RS485

WHEN OPTIONAL 64K INTERFACE IS MOUNTED THIS BUTTON SC6 NMS


IS ACTIVE.. CLICK ON SC4 BUTTON TO OPEN THE SC4
SETTING WINDOW. CLICK ON SC5 BUTTON TO OPEN THE SC5 SETTING WINDOW.

SC4

SC4

64K V.11 64K G703 9.6K RS-232

SELECT THE REQUIRED OPTION AND CLICK EXECUTE. CLICK CLOSE TO EXIT THE WINDOW

PNMT 29
NECITR-YTC
PMC CARD SETTING ART-SEP/03 V02

THE NAME ENTERED TO IDENTIFY THE NETWORK


ELEMENT CAN BE CHANGED FORM THIS WINDOW. A
FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE MAXIMUM OF 32 CHARACTERS CAN BE USED.
NAME BUTTON TO OPEN THE NE NAME SETTING
WINDOW.

ENTER THE NAME AND CLICK EXECUTE TO SHOW THE


NAME IN THE EQUIPMENT SETUP WINDOW.
CLICK THE NOTE BUTTON TO OPEN THE
NOTE WINDOW.

A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE


ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS
CAN BE USED IN THIS FIELD
ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE
NOTE IN THE EQUIPMENT SETUP WINDOW.

PNMT 30
MAINTENANCE NECITR-YTC
ART-SEP/03 V02

CLICK MAINTENANCE, ON THE,


TO CARRY OUT ANY MAINTENANCE CONTROL ,SET THE SELECTED NE TO
CONFIGURATION DROP DOWN
MAINTENANCE MODE. CLICK THE MAINT BUTTON ON THE MAINTENANCE
MENU TO OPEN THE WINDOW TO OPEN MAINTENANCE MODE SELECTION WINDOW. SELECT
MAINTENANCE WINDOW MAINT MODE ON OR OFF AND CLICK EXECUTE TO IMPLEMENT THE MODE
SELECTION
THIS CONTROL TRANSMIT AN UN-
MODULATED CARRIER FOR
MEASUREMENT PURPOSE.
CLICK THE CW BUTTON ON THE
MAINTENANCE WINDOW TO OPEN THE
CW CONTROL WINDOW. CLICK ON/OFF
AND EXECUTE TO IMPLEMENT THE
CONTROL.

THIS CONTROL INHIBIT INSERTION OF


AIS DURING BER ALARM CONDITION
FOR MEASUREMENT PURPOSE.
CLICK THE BER AIS BUTTON ON THE
MAINTENANCE WINDOW TO OPEN THE
BER AIS CONTROL WINDOW. CLICK
ON/OFF AND EXECUTE TO IMPLEMENT
THE CONTROL.

THIS CONTROL MUTE THE OUTPUT


THESE CONTROL ARE POWER OF THE SELECTED PASOLINK
AVAILABLE FOR (1+1) CHANNEL .
CONFIGURATION.
PROVIDES MANUAL CLICK THE TX MUTE BUTTON ON THE
SWITCH OVER OF MAINTENANCE WINDOW TO OPEN THE
PASOLINK CHANNEL TX MUTE CONTROL WINDOW. CLICK
ON/OFF AND EXECUTE TO IMPLEMENT
FOR NORMAL OPERATION THE CONTROL.
SELECT AUTO FOR AUTO
REDUNDANCY
SWITCHING..
TO CLOSE ANY MAINTENANCE CONTROL WINDOW CLICK CLOSE BUTTON. TO
NORMALIZE MAINTENANCE MODE NORMALIZE MAINTENANCE CONTROLS FIRST.

PNMT 31
AUX I/O WINDOW - MONITORING NECITR-YTC
ART-SEP/03 V02

AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE
PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS
ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS.
CLICK THE AUX SYMBOL IN THE BLOCK DIAGRAM OR AUX I/O TAB TO
VIEW THE AUX ALARM/STATUS/CONTROL DISPLAY CONFIGURE CONTROL RELAY OUTPUTS
CLICK THE OUTPUT 1-4 BUTTONS TO CONFIGURE
THE EXTERNAL CONTROLS
ENTER THE NAME TO
APPEAR FOR
SELECTED CONTROL
ITEM ( UP TO 32
CHARACTERS)

ENTER THE LABEL FOR


EACH CONDITION
EVENT ON AND EVENT
OFF

CLICK EXECUTE TO CARRY OUT THE CHANGE

ENTER THE SELECTED EXTERNAL ALARM NAME,


(UP TO 32 CHARACTERS)
CONFIGURE ALARM INPUTS
CLICK THE INPUT 1-6
BUTTONS TO CONFIGURE
THE EXTERNAL ALARM
SELECT THE CONDITION FOR
ALARM, EVENT ON OR EVENT
OFF
EXTERNAL MONITORING ITEMS ENTER THE LABEL FOR ALARM/ STATUS EVENT ON AND
CAN BE DEFINED AS ALARMS OR EVENT OFF.
AS STATUS CHANGE.
CLICK EXECUTE TO CARRY
CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW
OUT THE CHANGE

PNMT 32
PMC & VERSION WINDOWS NECITR-YTC
ART-SEP/03 V02

CLICK THE PMC SYMBOL ON THE BLOCK DIAGRAM OR CLICK THE VERSION TAB TO DISPLAY THE VERSION
THE PMC TAB TO DISPLAY THE PMC WINDOW FOR THE INFORMATION WINDOW FOR THE SELECTED NE.
SELECTED NE.

VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE ,


SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER
CONFIGURATION AND SETTING OF THE PASOLINK ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED
MANAGEMENT CARD IS PROVIDED IN THIS WINDOW. NETWORK ELEMENT.

PNMT 33
DATE TIME SETTING NECITR-YTC
ART-SEP/03 V02

DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENT’S PM CARD CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM
[PMC WINDOW]
TO DISPLAY THE CURRENT DATE/TIME
STORED IN THE PM CARD, SELECT
GET DATE/TIME AND CLICK EXECUTE.
CLICK DATE/TIME
BUTTON IN THE PMC
WINDOW TO OPEN THE THE CURRENT DATE/TIME STORED IN
DATE/TIME SETTING THE PM CARD, IS DISPLAYED.
CONTROL WINDOW

TO CHANGE THE PM CARD DATE TIME SETTING, TO CHANGE THE PM CARD DATE TIME SETTING,
SELECT SET DATE/TIME. SELECT SET DATE/TIME.

CHANGE THE DATE /TIME SETTING AS REQUIRED,


TO DISPLAY AND SET THE DATE/TIME SET IN THE
CLICK THE EXECUTE BUTTON.
PNMT PC TO THE PM CARD, SELECT DISPLAY PC
TIME BOX AND CLICK THE EXECUTE BUTTON.

PNMT 34
DOWN LOAD CONFIGURATION FILES NECITR-YTC
ART-SEP/03 V02

THIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE


NETWORK CONFIG TOOL TO THE PM CARD IN THE SELECTED NETWORK ELEMENT.
THERE ARE TWO FILES CREATED FOR EACH NE, SYSTEM.CFG CONTAINS THE IP
ADDRESS OF THE PM CARD AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION.
THE NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK
NETWORK WHERE THE PM CARD IS LOCATED.

CLICK THE CONFIGURATION FILE BUTTON UNDER THE


DOWNLOAD (PC>>PMC) IN THE PMC WINDOW, TO OPEN THE
DOWNLOAD CONFIGURATION FILE WINDOW.
DOWN LOAD
SELECT EACH CONFIG FILE ONE BY ONE FROM
[PMC WINDOW]
THE TYPE WINDOW
BROWSE AND SELECT THE PATH/LOCATION TO
THE FILE SELECTED IN THE TYPE WINDOW.
CLICK EXECUTE BUTTON TO DOWN LOAD THE
SELECTED CONFIG FILE..

REPEAT THE DOWNLOAD PROCEDURE FOR THE


OTHER CONFIG FILE..

UPDATE
A MESSAGE WINDOW INDICATE THE STATUS OF
AFTER THE SUCCESSFUL DOWN LOAD OF
THE DOWNLOAD OPERATION AND IT WILL CLOSE
THE CONFIGURATION FILES. CLICK
AUTOMATICALLY ONCE THE OPERATION IS OVER
UPDATE BUTTON. UPDATE
CONFIGURATION FILE WINDOW OPENS. System Config
WARNING
SELECT THE APPROPRIATE BOX FOR THE Network Config
MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWN
TYPE OF CONFIGURATION FILE(S) THAT ME Config LOADED TO THE PM CARD IN THE CORRECT NE. INCORRECT
WILL BE UPDATED. CONFIGURATION FILE WILL LEAD TO PM CARD OR NETWORK
PPP Config
CLICK OK BUTTON TO START THE UPDATE FAILURE
OPERATION..
MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED
With ROM (PMC Program ) Switching
WHEN UPDATING SYSTEM.CFG FILE , PMC TO THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE
PMC COMMUNICATION WILL BE LOST WHEN PM THE PM CARD WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE
CARD INITIALIZES TO THE NEW SYSTEM Execute PM CARD FAILURE.
CONFIGURATION. DURING THIS TIME PNMT
CONNECTION TO THE PASOLINK WILL BE LOST
BUT WILL AUTOMATICALLY BE RECONNECTED CLICK CLOSE BUTTON WHEN DONE
AFTER THE PMC RESETS

PNMT 35
DOWN LOAD PROGRAM FILE NECITR-YTC
ART-SEP/03 V02

THIS FUNCTION IS USED TO UPDATE THE APPLICATION PROGRAM ON THE PM


CARD. THIS OPERATION AFFECTS THE ONLY THE PMC TO PMC COMMUNICATION.
AND WILL NOT DISRUPT THE RADIO LINK.

CLICK ON THE PROGRAM FILE BUTTON UNDER THE DOWNLOAD (PC>>PMC) IN THE
PMC WINDOW.

[PMC WINDOW]
ENTER THE PATH TO THE
A:\pm.pof PROGRAM FILE TO BE
DOWNLOADED OR CLICK BROWSE
PM CARD CAN BE RESET TO LOCATE THE PROGRAM FILE.
USING THIS FUNCTION

CLICK THE PMC RESET CLICK THE EXECUTE BUTTON TO


BUTTON ON THE PMC START DOWNLOAD OPERATION
WINDOW.
A MESSAGE WINDOW APPEARS
TO SHOW THE STATUS OF THE
DOWNLOAD OPERATION, AND
WILL CLOSE AUTOMATICALLY
ONCE THE DOWNLOAD IS
COMPLETED.
CLICK ON THE PMC RESET
BUTTON TO SWITCH TO THE NEW WARNING
PROGRAM FILE MAKE SURE THAT THE CORRECT
PROGRAM FILE IS DOWNLOADED
TO THE PM CARD. INCORRECT
PROGRAM FILE WILL LEAD TO PM
SELECT WITH ROM (PMC PROGRAM) CARD FAILURE.
SWITCHING OPTION IF YOU WANT TO SWITCH
TO A NEWLY DOWNLOADED PMC PROGRAM
FILE RESETTING THE PMC WILL NOT AFFECT THE
TRAFFIC. THE CONNECTION TO THE
CLICK EXECUTE BUTTON TO RESET THE PM
SELECTED PASOLINK WILL BE LOST FOR FEW
CARD.
MINUTES AND WILL BE RECONNECTED
AUTOMATICALLY.

PNMT 36
UPLOAD CONFIGURATION FILE NECITR-YTC
ART-SEP/03 V02

THIS FUNCTION IS USED TO UPLOAD THE CONFIGURATION FILES FROM


THE PM CARD OF THE SELECTED NE TO THE PNMT PC.

[PMC WINDOW] CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (PM>>PC) TO OPEN
THE UPLOAD CONFIGURATION FILE WINDOW.

SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE


WINDOW., SYSTEM CONFIG OR NETWORK CONFIG.

ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN
THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF
NECESSARY.

CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE


WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION,
AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED..

AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE


THE WINDOW.

PNMT 37
EVENT LOG NECITR-YTC
ART-SEP/03 V02

NE SPECIFIC MENU BAR

A MESSAGE WINDOW
SHOWS THE PROGRESS OF
THE UPLOAD

CLICK ON THE EVEN LOG IN


THE NE SPECIFIC MENU BAR
TO UPLOAD THE EVEN LOG
ITEMS FROM THE SELECTED
NE.

EVENT LOG VIEW WINDOW SHOWS


ALARM EVENTS, COMMAND EVENTS
AND STATUS CHANGES.
DIFFERENT COLORS SHOWS THE
TYPE OF EVENT.
EVENT LOG IS PRESENTED IN A TABLE
FORM SHOWING THE DATE OF THE
EVENT , THE ITEM THAT TRIGGERED
THE EVENT AND THE STATUS
CHANGE.

CLICK FILE-UPLOAD TO REFRESH THE EVENT


LOG DISPLAY

CLICK FILE-SAVE AS TO SAVE THE EVENT


LOG TO

CLICK FILE-PRINT TO PRINT THE EVENT


LOG INFORMATION

PNMT 38
LINK PERFORMANCE MONITOR NECITR-YTC
ART-SEP/03 V02

NE SPECIFIC MENU BAR

THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED


CLICK ON THE LINK PERFORMANCE MONITOR IN THE NE ACCORDING TO THE G.826 RECOMMENDATIONS.
SPECIFIC MENU BAR OF THE LINK SUMMARY WINDOW OF
ES ERROR SECONDS
THE PASOLINK TO BE MONITORED.
SES SEVERELY ERROR SECONDS
UAS UNAVAILABLE SECONDS
BBE BACKGROUND BLOCK ERRORS

CURRENT BER VALUE IS SHOWN IN THIS FIELD

THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW


INDICATES THE OCCURRENCE OF PERFORMANCE ITEMS
EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUES
CAN BE SET IN THRESHOLD WINDOW. ALL DATA CAN BE RESET BY
USING ALL DATA RESET BUTTON. ( MAKE SURE THAT THE
CURRENT DATA HAS BEEN SAVED AS THIS OPERATION WILL
DELETE ALL THE PERFORMANCE DATA IN THE CURRENT WEEK.)

THRESHOLD VALUE SETTING


CLICK THE THRESHOLD(%) BUTTON TO OPEN THE THRESHOLD SETTING
WINDOW.

SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE


TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN
THE ALARM RECOVER IN THE APPROPRIATE FIELD.

AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TO


ACTIVATE THE NEW SETTING.

CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW..

PNMT 39
LINK PERFORMANCE MONITOR NECITR-YTC
ART-SEP/03 V02

THIS WINDOW CONTAINS THE LINK PERFORMANCE DATA OF


CLICK ON THE DETAIL BUTTON IN THE LINK PERFORMANCE THE LAST .8 DAYS.
MONITOR WINDOW TO DISPLAY THE WEEKLY DETAIL
WINDOW.

CLICK ON A DATE BUTTON TO DISPLAY THE DAILY DATA


WINDOW FOR THE SELECTED DATE

THE DATE BUTTONS ON THE RIGHT HAND SIDE OF THE


TABLE ARE SELECTABLE. AND CAN OPEN THE SUMMARY
DATA FOR THAT SPECIFIC DATE..

THE LINK PERFORMANCE MONITOR DAILY DATA WINDOW DISPLAY THE


DETAILED 15MIN PERFORMANCE DATA

CLICK FILE – SAVE AS TO SAVE THE DATA IN TEXT FORMAT

CLICK FILE - UPLOAD TO REFRESH THE DATA

PNMT 40
NECITR-YTC
ART-SEP/03 V02

PASOLINK V4 SOFTWARE

NEC International Training, Ltd.


Yokohama Training Center

PNMT 41

Anda mungkin juga menyukai