RANGKAIAN ELEKTROPNEUMATIK
SIKLUS A+B+A-B-
TOMBOL ON DI TEKAN, MENGAKTIFKAN AUTO SYSTEM, SEHINGGA MAKA ARUS MENGALIR DAN K1 AKTIF, K1 AKTIF MAKA
PADA RANGKAIAN K1 5 AKTIF SEHINGGA PADA RANGKAIAN K1 ON, MENGAKTIFKAN Y1 ON. JADI Y1 PADA RANGKAIAN
PNEUMATIC MENEKAN DAN SALURAN TERBUKA MENYEBABKAN FLUIDA KERJA MENGALIR MELALUI KATUP 5/2 DAN MENUJU
ONE WAY FLOW CONTROL KEMUDIAN MENGALIR DAN MENEKAN PISTON HINGGA PISTON A MENJADI A+ MENEKAN SENSOR
A2.
A2 AKTIF MAKA PADA RANGKAIAN ELEKTRO A2 ON K3 ON MENYEBABKAN K3 7 ON. PADA RANGKAIAN K3 TERSAMBUNG
MAKA PADA RANGKAIAN7 K3 TERSAMBUNG DAN Y3 ON MAKA RANGKAIAN PNEUMATIKNYA Y3 BERGESER DAN
MENYEBABKAN FLUIDA KERJA MENGALIR (KATUP 5/2) SEHINGGA FLUIDA MELEWATI ONE WAY FLOW CONTROL DAN
MENEKAN PISTON B MENJADI B+ DAN MENYENTUH SENSOR A4
A4 ON MAKA A4 PADA RANGKAIAN 2 ON DAN K2 PADA RANGKAIAN 6 TERSAMBUNG, KEMUDIAN MENYEBABKAN Y2
MENEKAN KATUP 5/2 BERGESER MENYEBABKAN FLUIDA KERJA MENGALIR DAN MENYEBABKAN PISTON A DARI
KONDISI A+ MENJADI A- DAN MENYENTUH SENSOR A1 ON
A1 ON MAKA PADA RANGKAIAN ELEKTRO 3 K4 ON, PADA SEMUA RANGKAIAN K4 TERSAMBUNG. MENYEBABKAN Y4
ON DAN PADA RANGKAIAN PNEUMATIKNYA Y4 MENEKAN KATUP 5/2 DAN BERGESER MENYEBABKAN FLUIDA KERJA
MENGALIR MENUJU PISTON B MELALUI ONE WAY FLOW CONTROL MENYEBABKAN PISTON DARI B+ MENJADI B-
KEMUDIAN MENYENTUH SENSOR A3
Pertanyaan

1. Bagaimana jika rangkaian tidak mau berjalan dengan normal?


Solusi : Pastikan rangkaian terpasang dengan benar, jangan sampai aliran salah.

2. Apa yang terjadi jika katub 5/2 B tidak berkerja?


Solusi: Maka piston B tidak akan bergerak. Harus di pastikan rangkaian katub 5/2 terpasang
dengan benar.