Spektroskopi Ir Bag II
Spektroskopi Ir Bag II
INFRARED
BAG II
TEORI DASAR, INSTRUMENTASI DAN ANALISIS SPEKTRUM
ZAENAL ARIFIN
ANALISIS INSTRUMEN SMK- SMAK BOGOR, 2O12
INSTRUMENTASI INFRARED
- SISTEM DISPERSIVE (KONVENSIONAL)
- FOURIER TRANSFORM (FT-IR)
DISPERSIVE SYSTEM
SUMBER
TEMPAT MONO- DETEKT INTEGRAT
OUTPUT
SAMPEL KROMATOR OR OR DATA
ENERGI
PERBEDAAN UTAMA SPEKTROFOTOMETER INFRARED DENGAN
VISIBEL/ULTRAVIOLET PADA CARA PENEMPATAN SAMPEL
SAMPEL HARUS MENDAPATKAN SPEKTRUM LENGKAP SUMBER ENERGI
SEHINGGA SELURUH BAGIAN SAMPEL BISA MENYERAP ENERGI SESUAI
DAERAH FREKUENSI VIBRASINYA
SPEKTROFOTOMETER INFRARED SISTEM DISPERSIF MELAKUKAN AKUISISI
DATA BERDASARKAN PROSES PEMINDAIAN
GRATING DIPUTAR DENGAN SUDUT TERTENTU SEHINGGA HANYA MENERIMA
BILANGAN GELOMBANG TERTENTU.
SETIAP NILAI DIPLOTKAN MENJADI SEBUAH PROFIL UTUH SPEKTRUM
INFRARED MOLEKUL YANG SEDANG DIBACA
WAKTU PEMBACAAN DAN PENGOLAHAN DATA RELATIF LAMA (MIN.10 MENIT)
FOURIER TRANSFORM
INFRARED
SUMBER INTERFER TEMPAT DETEKTOR &
OUTPUT
ENERGI OMETER SAMPEL INTEGRATOR
SAMPEL DISINARI DENGAN CAHAYA YANG SUDAH DIINTERFERENSI
MENGHASILKAN SEBUAH DATA ANALOG, INTERFEROGRAM.
PROSESOR DATA DIGUNAKAN UNTUK MENGKONVERSI
INTERFEROGRAM MENJADI SPEKTRUM INFRARED YANG DAPAT
DIANALISIS.
KEUNTUNGAN SISTEM FOURIER TRANSFORM ADA EFEK JACQUINOT
DAN EFEK FELLGETT
Efek JACQUINOT = SEMUA CAHAYA DILEWATKAN TANPA ADA SLIT
Efek FELLGET = INTERFERENSI CAHAYA YANG SATU FASE MAKIN
MENGUATKAN & WAKTU ANALISIS MAKIN CEPAT
WAKTU SCANNING CEPAT
INSTRUMENTASI INFRARED
SUMBER ENERGI: NERNST GLOBARTM YANG DIPANASKAN
PADA 1773K MENGGUNAKAN EFEK JOULE DENGAN
MENAMBAHKAN TAHANAN INTERNAL DARI RESISTOR.
DETEKTOR: BERUPA DETEKTOR PANAS (PYROELECTRIC
DETECTOR). DTGS (DETERIORATEDTRYGLICINESULFAT); LITA
(LITHIUMTANTALATOXIDE), MERCURY-CADMIUMTELURIDE),
INDIUMANTIMONIDE(INSB), GALENA(PBS),
INDIUMGALIUMARSENIC (INGAAS)
SUMBER ENERGI DAN
DETEKTOR
KEUNGGULAN FTIR
WAKTU ANALISIS LEBIH CEPAT DAN SIMULTAN EFEK FELGETT
SENSITIVITAS LEBIH BAIK EFEK JACQUINOT
LEVEL NOISE LEBIH RENDAH, KARENA JUMLAH SCAN LEBIH
BANYAK
SECARA MEKANIS LEBIH SEDERHANA HANYA MOVING
MIRROR YANG MERUPAKAN BAGIAN BERGERAK SHINGGA
MENGURANGI KEMUNGKINAN KERUSAKAN MEKANIS
SELF CALLIBRATED : MEMUNGKINKAN KALIBRASI INTERNAL
EFEK CONNES (LASER HE-NE SEBAGAI STANDAR KALIBRASI
PANJANG GELOMBANG INTERNAL)
HASIL AKURAT DAN REPRODUSIBEL (KETERULANGAN TINGGI)
BISA DIGUNAKAN UNTUK ANALISIS KUANTITATIF FAN ANALISIS
KUALITATIF
ANALISIS SPEKTRUM
SPEKTRUM INFRARED
SPEKTRUM INFRARED
SPEKTRUM INFRARED
ISOMER GUGUS FUNGSI
ALKOHOL – ETER, ALDEHID – KETON
ASAM KARBOKSILAT - ESTER
BUTANOL
DIETILETER
PROPANAL
PROPANONE
ASAM PROPIONAT
METILACETAT
PERTANYAAN
PERTANYAAN