Spray Spray and and gas gas rec|rcu|at|on rec|rcu|at|on contro|s contro|s
1he use of gas reclrculaLlon ln con[uncLlon wlLh spray
waLer for buck buck and boosL boosL acLlon has been Lrled on a few lnsLallaLlons llgure lllusLraLes such a scheme by Lhe use of characLerlsLlc curves 1he baslc characLerlsLlc ls glven ln Lhe upper parL of Lhe dlagram lndlcaLlng LhaL wlLhouL any conLrol Lhe LemperaLures wlll lncrease slowly buL never seLLle aL normal value 1he deslgned raLlo of heaLlng surfaces Lakes lnLo accounL Lhe boosL effecL of gas reclrculaLlon and buck effecL of spray waLer ln order Lo modlfy Lhe baslc characLerlsLlc Lo glve Lhe flnal characLerlsLlc as shown aL Lhe lower parL of Lhe dlagram spray and gas conLrollers 8k8Luu? 1 1he cenLre parL of Lhe dlagram shows how sLeam LemperaLure for boLh superheaL and reheaL ls conLrolled AL low flrlng raLes Lhe superheaL and reheaL LemperaLures are boosLed by gas reclrculaLlon wlLh gas bypass dampers closed Lhe superheaL rlslng fasLer Lhan reheaL as shown ln Lhe flnal characLerlsLlc curves ln Lhe lower parL of Lhe dlagram AL abouL 20 load Lhe LemperaLure of superheaLed sLeam has Lo be reduced by use of spray waLer Lhe demand for spray falllng gradually as Lhls LemperaLure comes nearer Lo seL polnL on Lhe regulaLor and gas reclrculaLlon also falllng 8eheaL ls conLrolled by gas reclrculaLlon unLll abouL 60 load when reheaL LemperaLure has reached lLs deslred value 8eclrculaLlon conLrol Lhen Lransfers Lo Lhe superheaL secLlons reheaL belng conLrolled by damper seLLlng Lo alLer Lhe bypasslng effecL ln Lhose secLlons spray and gas conLrollers 8k8Luu? 2 n Lhls way Lhe boosL glven by reclrculaLlon brlngs superheaL LemperaLure Lo Lhe deslred value and ls conLrolled by spray waLer ad[usLmenL Above abouL 94 load sLeam LemperaLure conLrol ls malnly by spray waLer for Lhe maln ouLleL and by gas bypass dampers for reheaL ouLleL gas reclrculaLlon belng unnecessary unless Lhere are sudden load changes or oLher LranslenL condlLlons spray and gas conLrollers 8k8Luu? 3 o||er o||er Ieed Ieed ump ump kec|rcu|at|on kec|rcu|at|on Contro| Contro| JaLer passes Lhrough a runnlng pump and plcks up heaL ln Lhe form of LemperaLure rlse a hlgh LemperaLure rlse can cause Lhe waLer Lo flash lnLo sLeam and cavlLaLlon cavlLaLlon resulLs when Lhe sLeam bubbles collapse lnslde Lhe pump Plgh LemperaLure also causes rubblng because of Lhe uneven expanslon of Lhe pump parLs lor pump proLecLlon Lhe LemperaLure rlse musL be mlnlmlzed by malnLalnlng a mlnlmum flow Lhrough Lhe pump aL all Llmes when Lhe pump ls runnlng lor small pumps Lhls ls usually accompllshed by lnsLalllng a permanenL reclrculaLlon llne from Lhe pump dlscharge Lo Lhe pump sucLlon wlLh an lnllne pressure breakdown orlflce plaLe Lo resLrlcL Lhe re clrculaLed flow Cn large pumps Lhe flow ls exLernally conLrolled because permanenL reclrculaLlon consumes Loo much unneeded pumplng power 1he reclrculaLlon conLrol valve of a boller feed pump can be regulaLed Lo malnLaln elLher a mlnlmum flow Lhrough Lhe pump or conLrol Lhe waLer LemperaLure rlse as lL passes Lhrough Lhe pump CavlLaLlon damages on a valve plaLe for an axlal plsLon hydraullc pump spray and gas conLrollers 8k8Luu? 4 f Lhe temperature r|se method ls used Lhe LemperaLure rlse ls deLermlned by Laklng Lhe dlfference beLween Lhe sucLlon flow LemperaLure and Lhe waLer LemperaLure aL Lhe balanclng head dlscharge of Lhe pump 1he response of LemperaLure sensors Lo LemperaLure changes ls also slow lor Lhese reasons Lhls meLhod ls seldom used 1he rec|rcu|at|on va|ves are hlghpressure drop valves n Lhe pasL a pressure breakdown orlflce was lnsLalled on Lhe reclrculaLlon llne aL Lhe ouLleL of Lhe conLrol valve Lo llghLen Lhe burden lmposed on Lhe valve n recenL years Lhe lmprovemenLs made on valve deslgn have vlrLually ellmlnaLed Lhls requlremenL 1he flow conLrol loop may be onoff 1he pump flow ls measured wlLh a hlghflow and a lowflow seL polnL Cn lncreaslng load Lhe valve sLays open unLll Lhe flow reaches Lhe hlgh seL polnL Above Lhls polnL Lhe reclrculaLlon valve ls closed Cn decreaslng load Lhe valve opens when Lhe flow reaches Lhe low seL polnL JlLh Lhls meLhod Lhe re clrculaLed flow ls more Lhan ls requlred when operaLlng beLween Lhe Lwo seL polnLs 1he modulaLlng conLrol modulaLes Lhe valve conLlnuously Lo conLrol Lhe flow preclsely aL Lhe mlnlmumflow when Lhe pump ls runnlng aL low loads spray and gas conLrollers 8k8Luu? 3 eaerator eaerator Storage Storage 1ank 1ank and and Condenser Condenser not not we|| we|| Leve| Leve| Contro| Contro| Loops Loops 1he condenser hoL well and Lhe deaerator sLorage Lank are Lhe Lwo reservolrs ln Lhe Lurblne cycle 1here are Lhree conLrol loops for Lhls sysLem (llg 1813) 1he deaeraLor serves as surge Lank for Lhe feed waLer 1he deaeraLor sLorage Lank level ls conLrolled by a conLrol valve on Lhe condensaLe supply llne a LhreeelemenL scheme can be used Lhe Lhree elemenLs are Lhe Lank level feed waLer flow ouL of Lhe Lank and condensaLe flow lnLo Lhe deaeraLor 1he condensaLe flow lnLo Lhe deaeraLor can be regulaLed by elLher modulaLlng a conLrol valve on Lhe condensaLe llne lnLo Lhe deaeraLor or by varylng Lhe speed of Lhe condensaLe pumps JlLh varlablespeed pumps Lhe pump dlscharge pressure varles wlLh load 1he condenser hot we|| serves as Lhe reservolr for waLer ln Lhe Lurblne cycle erlodlcally cycle makeup waLer ls needed because of waLer loss Lhrough waLer leakage sLeam venLlng or non recoverable sLeam usage durlng operaLlon 1he condensaLe level ln Lhe hoL well ls generally an lndlcaLlon of Lhe amounL of waLer ln Lhe Lurblne cycle 1he hoL well level can be conLrolled wlLhln a safe range by modulaLlng makeup and dump conLrol valves Jhen Lhe level reaches Lhe hlgh end of Lhe level range Lhe dump valve opens Lo dump Lhe excess condensaLe from Lhe condenser hoL well Lo a condensaLe sLorage Lank Jhen Lhe level reaches Lhe low polnL Lhe makeup valves open Lo supply makeup waLer Lo Lhe cycle spray and gas conLrollers 8k8Luu? 6 spray and gas conLrollers 8k8Luu? 7 1he g|and steam condenser and a|r e[ector are Lyplcally lnsLalled ln Lhe condensaLe sLream before Lhe condensaLe enLers Lhe lowpressure heaLers 1hey requlre a mlnlmum flow for proper operaLlon lor pump proLecLlon Lhe condensaLe flow Lhrough Lhe condensaLe pumps musL also be kepL above a mlnlmum value AL low loads Lhe condensaLe flow requlred Lo malnLaln Lhe deaeraLor Lank level wlll fall shorL of Lhe mlnlmum flow requlred 1hus a reclrculaLlon llne from Lhe condensaLe ouLleL of Lhe gland sLeam condenser Lo Lhe condenser ls provlded Lo keep Lhe condensaLe flow above Lhe mlnlmum 1he mlnlmum reclrculaLlon conLrol ls a slmple flow conLrol loop uslng Lhe measured condensaLe flow Lo close Lhe loop n sysLems equlpped wlLh a condensate po||sher a condensaLe bypass llne wlLh a conLrol valve around Lhe pollsher ls provlded Jhen Lhe pollsher becomes dlrLy or Lhe number of pollsher vessels ln servlce ls reduced durlng operaLlon Lhe condensaLe pressure drop across Lhe pollsher may exceed Lhe deslgn llmlL of Lhe pollsher under such condlLlons Lhe bypass valve opens Lo llmlL Lhe pressure dlfferenLlal by regulaLlng condensaLe flow bypasslng Lhe pollsher spray and gas conLrollers 8k8Luu? 8