Anda di halaman 1dari 54

12/29/2010

Turnotech Solutions

Switch OFF the BTS cabinet and disconnect Abis connectors from DDF before offline start

12/29/2010

Turnotech Solutions

Disconnect the Abis connector from The DDF

12/29/2010

Turnotech Solutions

Switch ON the BTS cabinet breakers and connect the Laptop with BTS

12/29/2010

Turnotech Solutions

User Name COMMTE

Password COMMTE

12/29/2010

Turnotech Solutions

Communication Port setting

12/29/2010

Turnotech Solutions

After connecting this window will be appear

12/29/2010

Turnotech Solutions

Go to Configuration-> BTS-SW Download-> to download BTS software

12/29/2010

Turnotech Solutions

After BTSSW download this window will appear

12/29/2010

Turnotech Solutions

Go to offline Files and select First File of Master File.

12/29/2010

Turnotech Solutions

Go to offline Files and select First File of DDL file.

12/29/2010

Turnotech Solutions

Click ok to start downloading SW

12/29/2010

Turnotech Solutions

BTS software starts to download.

12/29/2010

Turnotech Solutions

All these Files are downloaded

12/29/2010

Turnotech Solutions

Go to Configuration BTS commissioning

12/29/2010

Turnotech Solutions

Click start commissioning

12/29/2010

Turnotech Solutions

Edit Qmux Address

12/29/2010

Turnotech Solutions

Edit sector Mapping

12/29/2010

Turnotech Solutions

Check All Twin TREs.

12/29/2010

Turnotech Solutions

Click End Commissioning

Click << arrow to move selected modules to available modules

12/29/2010

Turnotech Solutions

All modules Shifted to update modules.

12/29/2010

Turnotech Solutions

Click No to end

12/29/2010

Turnotech Solutions

Reconnect the Abis connector at DDF by verifying the TX/RX cables properly

12/29/2010

Turnotech Solutions

Give Hard Reset to BTS cabinet as the OML has established to put the site on Downloading.

12/29/2010

Turnotech Solutions

OFF Line Commissioning Completed Successfully.

12/29/2010

Turnotech Solutions

Go to configuration>> Hardware setting>>Begin HW modification

12/29/2010

Turnotech Solutions

Go to configuration> BTS commissioning

12/29/2010

Go to start commissioning> Edit Q1 Address, Edit Sector Mapping and Twin TRA setting as in offline.

Turnotech Solutions

Go to configuration> Hardware setting>End Modification to end online commissioning

12/29/2010

Turnotech Solutions

Connect the Abis connector at DDF by verifying Tx/Rx cable properly. OML will be established after primary Abis has connected to DDF. Give hard reset to BTS after OML has established. Put site on Downloading from OMC. O&M will be established as downloading completes. Connect Laptop to BTS MMI port. Go to configuration>Hardware setting>Begin Hardware modification.
Turnotech Solutions

12/29/2010

Go to configuration>BTS commissioning>start commissioning. Edit Qmux Address Edit sector mapping Check all Twin TRA setting. Click end commissioning and shift all modules from selected modules to available modules. Go to configuration>Hardware setting>End Hardware modification. Click yes when an automatically hardware modification window appears. Hw Audit will be run and all Hardware will be shown after sometime.
Turnotech Solutions

12/29/2010

ON Line Commissioning Completed Successfully.

12/29/2010

Turnotech Solutions

combiner

Fan Unit

Hardware Shown in software window Tres clock


Alarm card

12/29/2010

Turnotech Solutions

Alarms window

12/29/2010

Turnotech Solutions

Transceivers Shown in window

12/29/2010

Turnotech Solutions

Four type of Transceivers in Alcatel Equipment TRAGE>Gsm Single TRE TRADE>Dcs single TRE TGT09>Gsm Twin TRE TGT18>DCS Twin TRE TAGHE>High power TRE

12/29/2010

Turnotech Solutions

VSWR Shown in window

12/29/2010

Turnotech Solutions

Sectors Shown In window

12/29/2010

Turnotech Solutions

Station units

12/29/2010

Turnotech Solutions

BSC SBLs (security block levels) BTS OM & Sectors.Sec RSLs can be unlock from local Terminal.

12/29/2010

Turnotech Solutions

If a TRE or combiner is in Not Operational or FOS state then disable it then initialize it by using init command. If TRE or combiner can not operational by doing above command then remove it by using the following method. Go to configuration>>Hardware setting>>Begin HW modification. Go to Configuration>>Hardware setting>>Remove. Remove the Hardware from BTS. Window will be appear of Hardware removal, select the module to remove. Go to Configuration>>Hardware setting>>End Modification. Click yes when configuration changes window appears.

12/29/2010

Turnotech Solutions

Hardware Removal Method Step:1

12/29/2010

Turnotech Solutions

Hardware Removal Step:2

12/29/2010

Turnotech Solutions

Hardware Removal Step:3

12/29/2010

Turnotech Solutions

When a module goes in FOS state then it must be disable by using disable command before initializing it by using init command otherwise it will not goes to operational state. When a module is in Not Operational state with color white then it means it has not got its RSL number still. Reload BTS data by going to configuration>Reload Bts data or using a method of Begin Hardware then End Hardware as discussed earlier. It will take some time to become operational. When a module is in MSD or MSA state then it will not get any command because its maintenance has seized for a while. When TRE RSL has locked then then its RSL will not be stable, so unlock the TRE from OMC.
Turnotech Solutions

12/29/2010

Sometime there is some faulty hardware in Bts thats why other sectors or TREs can effect and can not work properly. Due to these faulty hardware other sectors or TREs can be down so simply remove this hardware. By this method other hardware become in operational state. Some time SUMA can not work properly thats why whole Bts effects so change the slot of SUMA and give hard reset to Bts. If modules in a shelf can not powers up then check its power cable at the back ports of Bts or check it RI cable. Also check the power switch for the concern shelf. If a EACB card is Not operational or FIT state then initialize it from software. If it again goes in FIT state then Alarm card is faulty.
Turnotech Solutions

12/29/2010

Some time Primary Abis is stable by showing LED on Suma card but OML can not become stable, It means that Abis LED is fake. So check the Tx/Rx cable from both Bts end and microwave end and make sure that it is correctly connected. Also check Tx/Rx patching on DDF by using LED. Make sure that LED blinks on every pair on DDF. Also check the BNC and Abis connectors. Abis cable which is connected from Suma card to Bts board can be faulty so also verify it. If a TRE or combiner can not operational than change its slot then verify it. Vswr issues can be resolved by checking connectors from Bts end and feeder end. The last option for Alcatel equipment to become operational is the Hard reset of Bts.
Turnotech Solutions

12/29/2010

12/29/2010

Turnotech Solutions

AN
BCB BSII BSS BTS BTSW CCF CDM CLEI CLLK CPF CRC CU

A Antenna Network B BTS Control Bus Base Station Controller Base Station Subsystem Base Station Transceiver BTS-Terminal for Windows C Cabinet Cooling Fan Configuration Data Message Common Language Equipment Clock Link Configuration Parameter File Cyclic Redundancy Check Carrier Unit

12/29/2010

Turnotech Solutions

DC DMA EQU FIA FIM FIT FLT FOS ICS IT LDA LRA MI MSA MSD
12/29/2010

D Direct Current Deferred Maintenance Alarm E Equipped F Format Identifier for Application part of RI Format Identifier Manufacturing Faulty In Traffic Faulty Faulty Out of Service Item Change Status In Traffic L Local Defence Action Local Recovery Action M Maintenance Information MSD Auto Maintenance Seized
Turnotech Solutions

NEQ NOP O&M OMU OMUA OMUB OP OPR PADD PMA

N Not Equipped Not Operational O Operation and Maintenance Operation and Maintenance Unit OMU A RIT OMU B RIT Operational Operator P Physical Address Prompt Maintenance

12/29/2010

Turnotech Solutions

RA RF RFH RI RIT RX RTC SBL SCFE SOS SUM SUMP SW

R Radio Access Radio Frequency Radio Frequency Hopping ( also known as : Synthesizer Hopping ) Remote Inventory Replaceable Item Receiver or receive ..... Remote Tunable Combiner S Security Block Level Station Unit Control Function Entity RIT System Out of Service Station Unit Module SUM PCM RIT Software

12/29/2010

Turnotech Solutions

SBL SCFE SOS SUM SUMP SW TLV TRE TS TX VPMA VSWR


12/29/2010

S Security Block Level Station Unit Control Function Entity RIT System Out of Service Station Unit Module SUM PCM RIT Software T Tag, Length, Value Transceiver Module (combined Transmitter / Receiver functionality for base band and RF signals) Timeslot Transmitter or transmit . V Very Prompt Maintenance Alarm Voltage Standing Wave Ratio
Turnotech Solutions

WBC WTC XBCB XCLK XIOB

W Wide Band Combiner Wait Traffic Clear X External BCB External Clock External Input Output Board

12/29/2010

Turnotech Solutions

12/29/2010

Turnotech Solutions

Anda mungkin juga menyukai