PERHITUNGAN
R
t
Rt 24
t T
2/3
Dimana :
Rt
R24
R1 =
.( )
= 0,5503.R24
T = 2 jam
R2 =
.( )
= 0,3467.R24
T = 3 jam
R3 =
.( )
= 0,2646.R24
T = 4 jam
R4 =
.( )
= 0,2184.R24
T = 5 jam
R5 =
.( )
= 0,1882.R24
T = 6 jam
R6 =
.( )
= 0,1667.R24
2 jam
3 jam
4 jam
5 jam
6 jam
= 0,8
Nisbah %
C.H.efektif jam-jaman
55.0321
74.844
14.3040
19.453
10.0339
13.646
7.9880
10.864
6.7456
9.174
5.8964
8.019
Sumber :Perhitungan
Untuk Tr 50 tahun
Dengan : C.H rancangan 50 tahun ( R50 ) = 205 mm/hari
Koefisien Pengaliran (C)
Maka :
C.H efektif
= 0,8
= C x R50
= 0,8 x 205
= 164 mm/hari
Jam
Nisbah %
C.H.efektif jam-jaman
55.0321
90.253
14.3040
23.459
10.0339
16.456
7.9880
13.100
6.7456
11.063
5.8964
9.670
Sumber :Perhitungan
Untuk Tr 200 tahun
Dengan : C.H rancangan 200 tahun ( R200 )= 222 mm/hari
Koefisien Pengaliran (C)
Maka :
C.H efektif
= 0,8
= C x R200
= 0,8 x 222
= 177,6 mm/hari
Jam
Nisbah %
C.H.efektif jam-jaman
55.0321
97.737
14.3040
25.404
10.0339
17.820
7.9880
14.187
6.7456
11.980
5.8964
10.472
Sumber :Perhitungan
= 0,8
C.H efektif
= C x R1000
= 0,8 x 252
= 201,6 mm/hari
Jam
Nisbah %
C.H.efektif jam-jaman
55.0321
110.945
14.3040
28.837
10.0339
20.228
7.9880
16.104
6.7456
13.599
5.8964
11.887
Sumber :Perhitungan
Untuk Tr PMP tahun
Dengan : C.H rancangan PMP tahun ( RPMP )= 597 mm/hari
Koefisien Pengaliran (C)
= 0,8
= C x RPMP
= 0,8 x 597
= 477,6 mm/hari
Jam
Nisbah %
C.H.efektif jam-jaman
55.0321
262.833
14.3040
68.316
10.0339
47.922
7.9880
38.151
6.7456
32.217
5.8964
28.161
Sumber :Perhitungan
4.1.1.2 Perhitungan Hidrograf Banjir Rancangan dengan Nakayasu
Data :
Luas DAS (A)
= 212 km2
= 36 km
Parameter Alfa ()
=2
= 0,8
=1
Q baseflow
= 0,75 x tg
= 0,75 x 2,488
= 1,866
Waktu Puncak (Tp) adalah tenggang waktu dari permulaan hujan sampai puncak
banjir (jam)
Tp = tg + (0,8 x tr)
= 2,488+ (0,8 x 1,866)
= 3,981
Debit Puncak (Qp) adalah debit puncak banjir (m3/dt)
Qp = (A x Ro x 0,8)/[3,6(0,3 x Tp + T0,3)]
= (212x 1 x 0,8)/[3,6(0,3 x 3,981+ 4,976)]
= 7,635
Tabel 4.1 Tabel Waktu Lengkung Hidrograf Nakayasu
No
Karakteristik
1 Lengkung Naik
2 Lengkung Turun Tahap 1
3 Lengkung Turun Tahap 2
4 Lengkung Turun Tahap 3
Sumber :Perhitungan
Notasi
Qd0
Qd1
Qd2
Qd3
Awal (jam)
Notasi
Nilai
Akhir (jam)
Notasi
Nilai
0
0.000
Tp
3.981
Tp
3.981
Tp + T0,3
8.957
Tp + T0,3
8.957 Tp + 2,5 T0,3 16.421
Tp + 2,5 T0,3 16.421
24
24
Karakteristik
Notasi
1 Lengkung Naik
2 Lengkung Turun Tahap 1
3 Lengkung Turun Tahap 2
4 Lengkung Turun Tahap 3
Sumber : Data
Qd0
Qd1
Qd2
Qd3
Persamaan
Qp. (t/Tp)^2,4
Qp. 0,3^[(t-Tp)/T0,3]
Qp. 0,3^(t-Tp+0,5.T0,3)/(1,5.T0,3)
Qp. 0,3^(t-Tp+1.5T0.3)/(2.T0.3)
Tabel 4.3 Tabel Ordinat Hidrograf Satuan Sintetik dengan Metode Nakayasu
0
1
2
3
Q
(m3/dt)
0.0000
0.2773
1.4634
3.8724
4
5
6
7
8
9
10
11
12
13
7.7239
5.9666
4.6843
3.6776
2.8872
2.2667
1.9358
1.6474
1.4020
1.1932
14
15
1.0154
0.8642
16
17
0.7354
0.6407
18
19
20
21
22
0.5677
0.5030
0.4457
0.3949
0.3499
23
0.3100
24
25
0.2747
0.2434
t (jam)
ket
Qa
Qd1
Qd2
Qd3
26
0.2157
27
28
29
0.1911
0.1693
0.1500
30
0.1329
31
32
33
34
35
0.1178
0.1044
0.0925
0.0819
0.0726
36
0.0643
Sumber: Perhitungan
R(mm/hari)
7.00
6.00
5.00
4.00
3.00
2.00
1.00
0.00
12
16
20
24
t (jam)
28
32
36
HIDROGRAF NAKAYASU
3000.000
2500.000
Q BANJIR (m3/detik)
2000.000
Q 25 thn
1500.000
Q 50 thn
Q 200 thn
Q 1000 thn
1000.000
Q PMF
500.000
0.000
0
12
16
20
24
28
32
36
Dari hasil perhitungan banjir rancangan dengan Hidrograf Nakayasu di atas bisa
dibuat rekapan hujan rancangan netto dan debit banjir rancangan maksimum dari
masing-masing probabilitas adalah sebagai berikut:
JAM KE
HUJAN JAM-JAMAN
25th
50th
200th
1000th
PMF
74.8437
19.4534
13.6461
10.8637
9.1740
8.0191
90.2527
23.4586
16.4556
13.1003
11.0627
9.6701
97.7370
25.4039
17.8203
14.1867
11.9801
10.4720
110.9448
28.8369
20.2284
16.1038
13.5990
11.8871
262.8334
68.3159
47.9220
38.1507
32.2168
28.1612
Probabilitas Hujan
harian
Koefisien pengaliran
170.0000
205.0000
222.0000
252.0000
597.0000
0.7500
0.7500
0.7500
0.7500
0.7500
Hujan Efektif
127.5000
153.7500
166.5000
189.0000
447.7500
1
2
3
4
5
6
1.00
2.00
3.00
4.00
5.00
6.00
50
817.657
Qp ( m^3/detik
200
1000
885.297
1004.662
PMF
2377.354
Sumber : Perhitungan
: lingkaran
2. Diameter (data)
:9m
3. Panjang direncanakan
: 242,5 m
: + 60
: + 55
: 0,0206
7. Jumlah terowongan
:1
: 678.39 m3/dt
: 0,014
a. Pengaliran Bebas
Pada keadaan aliran bebas, kapasitas pengaliran dapat dihitung dengan
menggunakan rumusan dari MANNING :
V = Vn . R2/3 . S1/2
Q = A.V
Dimana :
Q = Debit yang melalui terowongan (m3/dt)
V = kecepatan aliran (m/dt)
A = Luas penampang basah (m2)
R = jari-jari hidrolis = A/P (m)
P = Keliling basah (m)
S = kemiringan dasar
n = angka kekasaran MANNING
Menghitung ; A, P dan B
KONDISI I
A = luas coba-coba - hOAB
=
- 2( .R2.sin.cos )
- R2.sin.cos
= R2 [
P =
X2
cos-1 [
=
]
B = jarak ab = 2R sin
KONDISI II
A = luas coba-coba acb
- R2 [
=
P =2
cos-1 [
Contoh Perhitungan
Untuk h = 0,5 , maka :
cos-1 [
A =
] = arc cos [
- R2 sin cos
= (27,266..4,5)/90 = 4,281
Tinggi
MA
(m)
(m)
(1)
(2)
60.5
0.5
61
1
61.5
1.5
62
2
62.5
2.5
63
3
63.5
3.5
64
4
64.5
4.5
Sumber: Perhitungan
El. MA
( o)
(3)
27.266
38.942
48.190
56.251
63.612
70.529
77.160
83.621
90.000
(m2)
(4)
1.386
3.857
6.961
10.517
14.409
18.550
22.869
27.303
31.793
(m)
(5)
4.281
6.117
7.570
8.836
9.992
11.079
12.120
13.135
14.137
(m)
(6)
0.324
0.631
0.920
1.190
1.442
1.674
1.887
2.079
2.249
(m)
(7)
0.297
0.793
1.371
1.979
2.584
3.157
3.679
4.132
4.498
(m/detik) (m3/detik)
(8)
(9)
4.835
6.699
7.542
29.088
9.699
67.511
11.519
121.140
13.091
188.627
14.463
268.285
15.661
358.166
16.705
456.101
17.605
559.715
Qc
(m3/detik)
(10)
9.380
26.648
49.128
75.926
106.578
140.832
178.579
219.834
264.744
F
Nilai
(11)
1.092
1.703
2.190
2.601
2.955
3.265
3.536
3.771
3.975
Keterangan:
(1)
(4)
(2)
(5)
keliling basah
(8) Kecepatan
(3)
(6)
jari-jari hidrolis
(9) Debit
Keterangan
(12)
superkritis
superkritis
superkritis
superkritis
superkritis
superkritis
superkritis
superkritis
superkritis
(10)
(11)
nilai Froude
(12)
Kondisi aliran
Dari tabel terlihat bahwa F > 1 untuk semua kedalaman, jadi kondisi
=h+
Vc
El MAW
dimana :
Qc
Vc
C1
b. Pengaliran Tertekan
Apabila tinggi muka air dibandingkan dengan diameter (H/D) > 1,5 maka aliran
yang terjadi adalah aliran tekan.
= Z2 + h2 +
+ hL
Z1 + h1 +
= Z2 + h2 +
Z1 + h1
= Z2 + h2 +[1+
[1+
[1+
=h
V
=[
]1/2
Jika h
Q
=A[
Dimana :
L sin = selisih tinggi antara inlet dan outlet = 10m
= jumlah koefisien kehilangan energi
= Co + Cf + C b + Ci
Co
Cf
Cb
Ci
Jadi
Besarnya debit yang keluar melalui terowongan dapat dihitung dengan rumus :
Q = A.V
]1/2
Q=A[
Q = 1/4
(9)2[
]1/2
= 1,5 . 9
= 13,5 m
El MAW
(m)
Tinggi
MA
(m)
(1)
73.5
70
(2)
13.5
10
El. MA
Ci
Cf
( o)
(m2)
(m)
(rounded)
(gesekan)
(6)
0.5
0.5
(7)
0.0433049
0.0433049
(3)
(4)
(5)
26.516 63.617 28.274
19.801 63.617 28.274
Co
(m)
(1)
60.000
60.500
61.000
61.500
62.000
62.500
63.000
63.500
64.000
64.500
65.000
65.500
66.000
66.500
67.000
67.500
68.000
Tinggi
MA
(m)
(2)
0.000
0.500
1.000
1.500
2.000
2.500
3.000
3.500
4.000
4.500
5.000
5.500
6.000
6.500
7.000
7.500
8.000
68.500
8.500
69.000
9.000
69.500
9.500
70.000
10.000
Sumber: Perhitungan
Q
(m3/detik)
(3)
0.000
6.699
29.088
67.511
121.140
188.627
268.285
358.166
456.101
559.715
634.921
710.127
785.332
860.538
935.743
1010.949
1506.098
1543.127
1580.156
1617.185
1654.214
jenis
pengaliran
(4)
bebas
transisi
tertekan
(9)
30.077
26.003
(10)
1913.415
1654.214
h (meter)
6
5
Series1
3
2
1
0
0
150
300
450
debit (m3/det)
600
Elevsi (m)
68.000
66.000
64.000
62.000
60.000
58.000
0
200
400
600
800
1000
1200
Q (m3/detik)
1400
1600
1800
Elevasi
S/t
(m)
(m)
(m3)
(m3)
(m3/detik)
(1)
(2)
(3)
(4)
(5)
60.0
0
0
0
0.000
60.5
0.5
287500
287500
79.861
61.0
1
575000
575000
159.722
61.5
1.5
862500
862500
239.583
62.0
2
1150000
1150000
319.444
62.5
2.5
1437500
1437500
399.306
63.0
3
2300000
2300000
638.889
63.5
3.5
3162500
3162500
878.472
64.0
4
4025000
4025000
1118.056
64.5
4.5
4887500
4887500
1357.639
65.0
5
5750000
5750000
1597.222
65.5
5.5
7187500
7187500
1996.528
66.0
6
8625000
8625000
2395.833
66.5
6.5 10062500 10062500 2795.139
67.0
7
11500000 11500000 3194.444
67.5
7.5 12937500 12937500 3593.750
68.0
8
14950000 14950000 4152.778
68.5
8.5 16962500 16962500 4711.806
69.0
9
18975000 18975000 5270.833
69.5
9.5 20987500 20987500 5829.861
70.0
10
23000000 23000000 6388.889
Sumber: Perhitungan
1. Data
4. (3)n+1 - (3)n
2. Data
5. (4)/ 3600
3. Data
6. Data Outflow Pengelak
Psi
Q
Q/2
y = S/t
- Q/2
3
3
(m /detik) (m /detik) (m3/detik)
Phi
= S/t
+ Q/2
(m3/detik)
(6)
0.000
6.699
29.088
67.511
121.140
188.627
268.285
358.166
456.101
559.715
634.921
710.127
785.332
860.538
935.743
1010.949
1506.098
1543.127
1580.156
1617.185
1654.214
(9)
0.000
83.211
174.266
273.339
380.015
493.619
773.031
1057.555
1346.106
1637.497
1914.683
2351.591
2788.499
3225.408
3662.316
4099.224
4905.827
5483.369
6060.911
6638.454
7215.996
(7)
0.000
3.349
14.544
33.755
60.570
94.314
134.142
179.083
228.050
279.858
317.461
355.063
392.666
430.269
467.872
505.474
753.049
771.564
790.078
808.592
827.107
(8)
0.000
76.512
145.178
205.828
258.874
304.992
504.746
699.389
890.005
1077.781
1279.762
1641.464
2003.167
2364.870
2726.573
3088.276
3399.729
3940.242
4480.755
5021.269
5561.782
7. (6)/2
8. (5)-(7)
9. (5)+(7)
Inflow
(I)
(m3/det)
(2)
2.000
22.751
116.920
324.079
678.399
670.101
631.778
580.961
520.287
445.568
361.151
296.559
246.001
206.035
174.175
148.581
126.745
109.269
95.257
83.491
73.523
65.030
57.760
51.407
45.777
40.789
36.369
32.453
28.983
25.908
23.184
20.770
18.631
16.736
15.057
13.569
12.251
(I1+I2)/2
j2
(m3/det)
(3)
0.000
12.376
69.836
220.499
501.239
674.250
650.939
606.370
550.624
482.927
403.359
328.855
271.280
226.018
190.105
161.378
137.663
118.007
102.263
89.374
78.507
69.277
61.395
54.583
48.592
43.283
38.579
34.411
30.718
27.445
24.546
21.977
19.701
17.684
15.897
14.313
12.910
(m3/det)
(4)
0.000
0.175
0.088
0.493
4.133
58.737
119.112
133.668
121.147
101.469
76.285
51.354
21.288
6.916
4.539
3.239
2.339
1.809
1.375
1.026
0.741
0.559
0.492
0.436
0.388
0.345
0.308
0.274
0.244
0.218
0.195
0.174
0.156
0.140
0.126
0.113
0.102
(m3/det)
(5)
0.000
12.551
69.924
220.992
505.372
732.986
770.052
740.038
671.771
584.396
479.644
380.209
292.568
232.934
194.644
164.617
140.002
119.817
103.638
90.400
79.248
69.835
61.887
55.020
48.979
43.628
38.886
34.685
30.962
27.664
24.741
22.151
19.857
17.824
16.022
14.426
13.012
max
Sumber : Perhitungan
1. Data
2. Data
3. [(2)n+1 - (2)n]/2
Outflow
(Q)
(m3/det)
(6)
2.000
1.010
5.629
47.209
191.978
256.869
267.435
258.879
239.417
214.507
180.326
121.256
77.178
51.841
36.991
26.715
20.663
15.700
11.722
8.467
6.380
5.622
4.982
4.429
3.943
3.512
3.131
2.792
2.493
2.227
1.992
1.783
1.599
1.435
1.290
1.161
1.048
267.435
4. interpolasi (7)
5. (3)+(4)
6. interpolasi (5)
Elevasi
(m)
(7)
0.149
0.075
0.420
1.236
2.521
2.928
2.995
2.941
2.819
2.662
2.438
2.001
1.590
1.296
1.103
0.947
0.812
0.701
0.612
0.539
0.476
0.420
0.372
0.331
0.294
0.262
0.234
0.208
0.186
0.166
0.149
0.133
0.119
0.107
0.096
0.087
0.078
2.995
(m)
(8)
60.149
60.075
60.420
61.236
62.521
62.928
62.995
62.941
62.819
62.662
62.438
62.001
61.590
61.296
61.103
60.947
60.812
60.701
60.612
60.539
60.476
60.420
60.372
60.331
60.294
60.262
60.234
60.208
60.186
60.166
60.149
60.133
60.119
60.107
60.096
60.087
60.078
62.995
7. interpolasi (6)
8. 35 + (7)
Q (m3/detik)
600
500
400
inflow
outflow
300
200
100
0
0
12
16
20
24
28
32
T (jam)
36
40
No.
Elevasi
Selisih
dengan
Kontur
Terendah
(m)
(m)
(1)
(2)
1
60
2
62.5
3
65
4
67.5
5
70
6
72.5
7
75
8
77.5
9
80
10
82.5
11
85
12
87.5
13
90
14
92.5
15
95
16
97.5
17
100
18
102.5
19
105
20
107.5
21
110
Sumber : Perhitungan
(3)
0
2.5
5
7.5
10
12.5
15
17.5
20
22.5
25
27.5
30
32.5
35
37.5
40
42.5
45
47.5
50
(4)
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
1.15
Luas Kontur
(daerah
genangan)
Volume
Antar
Interval
Kontur
Volume
Tampungan
Waduk
(m2)
(m2)
(m3)
(m3)
(5)
0
2875000
5750000
8625000
11500000
14375000
17250000
20125000
23000000
25875000
28750000
31625000
34500000
37375000
40250000
43125000
46000000
48875000
51750000
54625000
57500000
(6)
0
1437500
4312500
7187500
10062500
12937500
15812500
18687500
21562500
24437500
27312500
30187500
33062500
35937500
38812500
41687500
44562500
47437500
50312500
53187500
56062500
(7)
0
1437500
4312500
7187500
10062500
12937500
15812500
18687500
21562500
24437500
27312500
30187500
33062500
35937500
38812500
41687500
44562500
47437500
50312500
53187500
56062500
(8)
0
1437500
5750000
12937500
23000000
35937500
51750000
70437500
92000000
116437500
143750000
173937500
207000000
242937500
281750000
323437500
368000000
415437500
465750000
518937500
575000000
1. Data
4. Data
2. Data
(2)n 3.
30
5. (3)*(4)*10^6
6. [(5)n+(5)n+1]/2
(6)*tinggi
kontur
8. (7)n-1 + (7)n
7.
50
40
30
20
Millions
10
120
100
Elevasi (m)
80
60
Volume
tampungan
40
20
0
0.00
100.00
200.00
300.00
400.00
Volume (juta m3)
500.00
600.00
700.00
Millions
Untuk tinggi cofferdam hulu dapat dilihat dari dari tabel 4.14 yang mana
tingginya diambil 14 m. hal ini dikarenakan pada Q 25 debit maksimumnya
adalah 1406,273 m3/dt. Sehingga tinggi total cofferdam hulu adalah:
H = 12 + tinggi jagaan
= 12 + 2
= 14 m
4.3.2 Lebar Atas Cofferdam
Lebar atas cofferdam ditentukan berdasarkan ketentuan agar dapat bertahan
terhadap hempasan ombak, serta dapat bertahan terhadap aliran filtrasi yang
melalui bagian puncak cofferdam untuk memperoleh lebar minimum mercu
cofferdam bisa dihitung dengan rumus :
b = 3,6 H1/3 3
dimana :
b = lebar mercu
H = tinggi bendungan
Jadi lebar hulu:
b = 3,6 . 141/3 3
= 5,676 m = 6 m
lebar hilir:
b = 3,6 . 141/3 3
= 5,676 m = 6 m
4.3.3 Penentuan Kemiringan Lereng (Talud) Cofferdam
Rumus pendekatan yang dipergunakan untuk menentukan kemiringan talud
cofferdam adalah sebagai berikut :
Fs hulu =
Fs hilir =
tan
tan
Dimana :
Fs = faktor keamanan (1,1)
m,n= kemiringan lereng (hulu, hilir)
k = koefisien gempa (0,17)
= sudut geser dalam material
/(
= 19,588
= 2,45 t/m3
= 55 % 0,55
d. Kohesi (c)
f. Sr
= 65% = 0,65
g. w
= 1 KN/m3
h. sat
= 19,35 KN/m3
i. dry
= 15,8 KN/m3
=
=
tan
=2
tan
= 1,5
Y0
=
=
=
Tabel 4.18 Koordinat Garis Rembesan
X
-3,285
6,57
7,50
8,33
9,09
9,78
10,43
11,04
11,62
Sumber: Perhitungan
Kontrol Keamanan Terhadap Piping Pondasi
Pada prinsipnya kontrol keamanan terhadap piping pondasi ini adalah
memeriksa
gradient
hidraulik
rata-rata
dan
gradient
hidraulik
FX
ic
5
im
dengan :
ic = gradient hidraulik kritis
im = gradient hidraulik rata-rata
'
ic
w
dengan :
= sat w
sat =
Gs e
w
1 e
Gs 1
'
.w
1 e
ic
Gs 1
1 e
kritis,
im
H
L
Fs
Gs 1 L
.
1 e H
= 2,45 t/m3
= 55 % 0,55
c. H
= 12 m
d. Lc (gambar)
= 41,6 m
Fs = ic/im
ic = sub / w =
im = H/Lc 0,288
Fs =
Gs 1 0,9355
1 e
ic
im
3,24
( TANPA GEMPA )
Dengan :
Fs
= berat beban
Ne
= N x faktor gempa ( N x e )
Te
= T x factor gempa ( T x e )
Irisan
1
1
2
3
4
5
6
b
2
4.9
4.9
4.9
4.9
4.9
4.9
h
3
3.9323
6.6
8.4
7.5
5.4
2.1
4
15.8
18.4
18.4
18.4
18.4
18.4
tan
13
0.5
0.5
0.8
0.8
0.8
0.8
(N - Ne)
Te
14
15
75.723
28.115
221.103 73.797
541.802 107.121
530.384 100.769
376.544 72.122
131.570 26.261
1877.126 408.185
b/cos
16
7.959
5.910
5.182
4.919
4.948
5.285
34.203
Sumber: Perhitungan
Keterangan:
1 Dari gambar
2 Dari gambar
3 Dari gambar
C
C1
Fs
= 0,0306 ton/m3
Dari
7 gambar
8 sin (7)
9 cos (7)
4 Data
5 Data
6 (2)*(3)*(4)
= 0,256
= 1,319
10 (6)*(8)
11 (6)*(9)
12 0.15*(10)
13 Data
16 (2)/(9)
14 ((11)-(12))*(13)
15 0.15*(11)
Wn
sin n
cos n
Ne
tan
(N - U - Ne)
Te
10
11
12
13
14
15
16
b/cos
17
1
2
3
4
5
4.9
4.9
4.9
4.9
4.9
3.932
6.6
8.4
7.5
5.4
15.8
18.4
18.4
18.4
18.4
30.6
30.6
30.6
30.6
30.6
304.44
593.44
755.29
674.36
485.54
52
34
19
5
8
0.788
0.559
0.326
0.087
0.139
0.616
0.829
0.946
0.996
0.990
239.901
331.847
245.897
58.775
67.574
187.431
491.983
714.137
671.796
480.816
35.985
49.777
36.885
8.816
10.136
31.297
0
0
0
0
0.5
0.5
0.8
0.8
0.8
60.075
221.103
541.802
530.384
376.544
28.115
73.797
107.121
100.769
72.122
7.959
5.910
5.182
4.919
4.948
4.9
2.1
18.4
30.6
188.82
22
0.375
0.927
70.734
175.072
10.610
0.8
131.570
26.261
5.285
1014.727 2721.236
152.209
31.297
1861.477
408.185
34.203
Jumlah
Sumber: Perhitungan
Keterangan:
1 Dari gambar
2 Dari gambar
3 Dari gambar
C1
Fs
4 Data
5 Data
6 (2)*(3)*(4)
= 0,0306 ton/m3
7 Dari gambar
8 sin (7)
9 cos (7)
= 0,128
= 1,308
10 (6)*(8)
11 (6)*(9)
12 0.15*(10)
13 1*(3)*(17)
14 Data
15 ((11)-(12)-(13))*(14)
16 0,15*(11)
17 (2)/(9)
b
h
c
Wn
2
3
4
5
6
4.9 3.932 15.8 30.6 304.44
4.9 6.6 18.4 30.6 593.44
4.9 8.4 18.4 30.6 755.29
4.9 7.5 18.4 30.6 674.36
4.9 5.4 18.4 30.6 485.54
4.9 2.1 18.4 30.6 188.82
Jumlah
Sumber: Perhitungan
Keterangan:
1 Dari gambar
4 Data
2 Dari gambar
5 Data
3 Dari gambar
6 (2)*(3)*(4)
Irisan
1
1
2
3
4
5
6
C1
Fs
= 0,0306 ton/m3
7 Dari gambar
8 sin (7)
9 cos (7)
= 0,256
= 1,309
10 (6)*(8)
11 (6)*(9)
12 0.15*(10)
13 1*(3)*(17)
14 Data
15 ((11)-(12)-(13))*(14)
b/cos
17
7.955
5.911
5.185
4.920
4.949
5.286
34.206
16 0,15*(11)
17 (2)/(9)
Nf
.k .H .B
Np
dengan :
Qf
Nf
Np
Nf = 3 dan Np =8
K = 3,29 . 10-9 m/det
3
Qf .3,29.10 9.12.204 3,02.10 6 m 3 / det
8
= k.H.(T/(B+T))
Dengan :
K = koefisien permeabilitas
T = Tebal lapisan pondasi
B = lebar dasar kedap air
H = beda tinggi tekanan air
Qfpond = 3,29 . 10-9.12.( 1,1/(41,6+1,1))
= 1,02. 10-9 m3/det